Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 191
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Blood ; 139(7): 1080-1097, 2022 02 17.
Artículo en Inglés | MEDLINE | ID: mdl-34695195

RESUMEN

In an effort to identify novel drugs targeting fusion-oncogene-induced acute myeloid leukemia (AML), we performed high-resolution proteomic analysis. In AML1-ETO (AE)-driven AML, we uncovered a deregulation of phospholipase C (PLC) signaling. We identified PLCgamma 1 (PLCG1) as a specific target of the AE fusion protein that is induced after AE binding to intergenic regulatory DNA elements. Genetic inactivation of PLCG1 in murine and human AML inhibited AML1-ETO dependent self-renewal programs, leukemic proliferation, and leukemia maintenance in vivo. In contrast, PLCG1 was dispensable for normal hematopoietic stem and progenitor cell function. These findings are extended to and confirmed by pharmacologic perturbation of Ca++-signaling in AML1-ETO AML cells, indicating that the PLCG1 pathway poses an important therapeutic target for AML1-ETO+ leukemic stem cells.


Asunto(s)
Subunidad alfa 2 del Factor de Unión al Sitio Principal/metabolismo , Regulación Leucémica de la Expresión Génica , Células Madre Hematopoyéticas/patología , Leucemia Mieloide Aguda/patología , Células Madre Neoplásicas/patología , Proteínas de Fusión Oncogénica/metabolismo , Fosfolipasa C gamma/metabolismo , Proteína 1 Compañera de Translocación de RUNX1/metabolismo , Animales , Autorrenovación de las Células , Subunidad alfa 2 del Factor de Unión al Sitio Principal/genética , Células Madre Hematopoyéticas/metabolismo , Humanos , Leucemia Mieloide Aguda/genética , Leucemia Mieloide Aguda/metabolismo , Ratones , Células Madre Neoplásicas/metabolismo , Proteínas de Fusión Oncogénica/genética , Fosfolipasa C gamma/genética , Proteoma , Proteína 1 Compañera de Translocación de RUNX1/genética , Transcriptoma , Translocación Genética
2.
Knee Surg Sports Traumatol Arthrosc ; 32(5): 1199-1206, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38511851

RESUMEN

PURPOSE: The purpose of this study was to find out whether the torsions of the femur and tibia are dependent on the coronal plane alignment of the knee (CPAK) type. METHODS: Five hundred patients (1000 legs) were included, who received a whole leg standing three-dimensional (3D) radiograph using EOS imaging (EOS Imaging, Paris, France). SterEOS software was used for digital reconstruction. Femoral and tibial torsions were determined by analysing 3D reconstructions of each leg. Femoral torsion was defined as the angle between the femoral neck axis (FNA) and the posterior condylar axis (PCA). Tibial torsion was defined as the angle between the axis tangent to the posterior part of the tibia plateau and the transmalleolar axis. Arithmetic hip-knee-ankle angle (aHKA) and joint-line obliquity (JLO) were also determined, allowing each leg to be assigned one of nine possible phenotypes according to CPAK. RESULTS: The mean femoral torsion in CPAK type 1 was significantly higher (+ 2.6° ± 0.8°) than in CPAK type 4 (p = 0.02). All other CPAK types did not differ in the degree of femoral torsions. No differences could be demonstrated for the tibial torsion. CONCLUSION: There is a correlation between the coronal alignment of the lower limb and femoral torsion. This may provide the basis for extending the CPAK classification beyond the coronal plane. LEVEL OF EVIDENCE: Level III.


Asunto(s)
Fémur , Imagenología Tridimensional , Articulación de la Rodilla , Tibia , Humanos , Fémur/diagnóstico por imagen , Fémur/anatomía & histología , Femenino , Masculino , Adulto , Articulación de la Rodilla/diagnóstico por imagen , Persona de Mediana Edad , Tibia/diagnóstico por imagen , Anciano , Anomalía Torsional/diagnóstico por imagen , Adulto Joven , Radiografía , Adolescente
3.
Int J Mol Sci ; 25(4)2024 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-38396718

RESUMEN

Previously, we demonstrated that renal denervation in pigs reduces renal glucose release during a hypoglycemic episode. In this study we set out to examine changes in side-dependent renal net glucose release (SGN) through unilateral low-frequency stimulation (LFS) of the renal plexus with a pulse generator (2-5 Hz) during normoglycemia (60 min) and insulin-induced hypoglycemia ≤3.5 mmol/L (75 min) in seven pigs. The jugular vein, carotid artery, renal artery and vein, and both ureters were catheterized for measurement purposes, blood pressure management, and drug and fluid infusions. Para-aminohippurate (PAH) and inulin infusions were used to determine side-dependent renal plasma flow (SRP) and glomerular filtration rate (GFR). In a linear mixed model, LFS caused no change in SRP but decreased sodium excretion (p < 0.0001), as well as decreasing GFR during hypoglycemia (p = 0.0176). In a linear mixed model, only hypoglycemic conditions exerted significant effects on SGN (p = 0.001), whereas LFS did not. In a Wilcoxon signed rank exact test, LFS significantly increased SGN (p = 0.03125) and decreased sodium excretion (p = 0.0017) and urinary flow rate (p = 0.0129) when only considering the first instance LFS followed a preceding period of non-stimulation during normoglycemia. To conclude, this study represents, to our knowledge, the first description of an induction of renal gluconeogenesis by LFS.


Asunto(s)
Glucosa , Hipoglucemia , Animales , Porcinos , Glucosa/farmacología , Hipoglucemiantes/farmacología , Riñón , Hipoglucemia/inducido químicamente , Sodio/farmacología , Tasa de Filtración Glomerular , Glucemia
4.
Arch Orthop Trauma Surg ; 144(1): 433-438, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37530843

RESUMEN

INTRODUCTION: The correct adjustment of leg length is a major goal in the implantation of total hip replacements (THRs). Differences in leg length can lead to functional impairment and patient dissatisfaction. By determining leg length at an early stage, before the patient is discharged from hospital, compensatory measures such as the production of special insoles or orthopaedic footwear can be initiated promptly if there is a difference in leg length. Due to shortening of the period of time spent in hospital, the traditional measurement of leg length in a standing position may be increasingly subject to error. A protective posture immediately after surgery or the presence of a twisted pelvis, for example, due to scoliotic spinal misalignments, falsifies the measurement result in the standing position. Here, the measurement of leg length in the supine position may prove to be accurate immediately postoperatively, regardless of potential sources of error, and is to be compared with measurement in the standing position versus radiological measurement on the AP pelvic survey. MATERIAL AND METHODS: The present retrospective study included 190 patients who had undergone primary total hip arthroplasty. The leg length difference (LLD) of the patients was determined pre- and postoperatively both in the supine and standing position and compared with the postoperative radiological pelvic survey image. RESULTS: Postoperatively, it was shown that the mean length measured was 0.35 mm too long in the supine position and 0.68 mm too short in the standing position (p value < 0.001). Determination of the average absolute measurement error produces a deviation of 4.06 mm in the standing and 4.51 mm in the supine position (p value 0.126). CONCLUSIONS: It is shown that the postoperative measurement of LLD in the supine and standing position is equally valid and sufficiently accurate, compared with the gold standard of measurement on a radiograph.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Humanos , Artroplastia de Reemplazo de Cadera/métodos , Posición de Pie , Estudios Retrospectivos , Pierna , Rayos X , Posición Supina
5.
Arch Orthop Trauma Surg ; 144(5): 2267-2271, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38587669

RESUMEN

The symmetry of the flexion and extension gap influences the functional and long-term outcome after total knee arthroplasty (TKA). Most surgeons check it by applying varus and valgus stress using spacers. This technique has limited accuracy and could be easily extended by rotational movement of the spacer. The objective was to determine the detection threshold and interobserver reliability of this technique. In an in vitro setting with a human cadaveric knee, gap asymmetries were simulated by different medially and laterally applied forces. Using an optical measurement system, the pivot point of the spacer was calculated as a function of the gap symmetry in the first part of the experiment. In the second part, the detection threshold and interobserver reliability of 4 surgeons were determined. For this purpose, gap asymmetries were adjusted to between 0 and 120N in a blinded trial. With a symmetrical gap, the centre of rotation of the spacer was located in the centre of the tibia. With increasing gap asymmetry, the centre of rotation of the spacer shifted to the tight side. This shift was approximately linearly dependent on the force difference. A perfectly balanced gap was detected by the examiners in 50% of the cases. From a force difference of 40N, all examiners identified the gap asymmetry in all cases (ICC = 1.0). The method of spacer rotation described is suitable for reliably detecting gap differences at ≥ 40N, independently of the examiner.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Cadáver , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Rotación , Prótesis de la Rodilla , Rango del Movimiento Articular , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/fisiología , Articulación de la Rodilla/fisiopatología , Fenómenos Biomecánicos , Variaciones Dependientes del Observador
6.
Arch Orthop Trauma Surg ; 144(5): 2283-2295, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38625551

RESUMEN

INTRODUCTION: The rate of revision TKA and thus the use of hinged implants (HI) steadily rises. Aseptic loosening lies on the top of the failure patterns. However, no evidence exists until now based on national scale high-caseloads that analyzes the impact of cemented HI stem-design on aseptic survival rates. METHODS: Data on aseptic HI-revisions with full-cemented tibia-stems were conducted from the German Arthroplasty Registry. Cases were divided in primary HI (PHI) and HI used in revision operations (RHI). Endpoint was a new revision following either a PHI or an RHI. The impact of stem conicity (conical vs. cylindrical), diameter (≤ 13 mm vs. > 13 mm), length (≤ 90 mm vs. > 90 mm) and offset on the 6-Year-Cumulative-Aseptic-Revision-Rate (6Y-CARR) was estimated via Kaplan-Meier curve and compared between groups via Log-Rank-Tests. RESULTS: 3953 PHI and 2032 RHI fulfilled inclusion-criteria. Stem conicity had no impact on 6Y-CARR (p = 0.08 and p = 0.8). Diameter > 13 mm hat an impact on PHI (p = 0.05) with lower 6Y-CARR but not on RHI (p = 0.2). Length > 90 mm showed significantly worst 6Y-CARR in PHI (p = 0.0001) but not in RHI (p = 0.3). Offset-stems showed significantly better 6Y-CARR in PHI (p = 0.04), but not in RHI (p = 0.7). CONCLUSION: There was no significant impact of the cemented tibia-stem conicity on 6Y-CARR, neither in PHI nor in RHI. The effect of length, diameter and offset on the 6Y-CARR observed in the PHI, was not detectable in the more complex RHI-cases reflecting its limited clinical relevance by itself in more multifactorial backgrounds. Therefore, results must be interpreted with caution due to considerable system-effects and different utilization-scenarios.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Diseño de Prótesis , Falla de Prótesis , Sistema de Registros , Reoperación , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Artroplastia de Reemplazo de Rodilla/instrumentación , Alemania/epidemiología , Reoperación/estadística & datos numéricos , Masculino , Anciano , Femenino , Tibia/cirugía , Persona de Mediana Edad , Cementos para Huesos
7.
Artículo en Inglés | MEDLINE | ID: mdl-38987503

RESUMEN

PURPOSE: Modular cementless knee arthroplasty systems are capable of precise reconstruction of the mechanical axis. However, they are considered more susceptible to complications. In contrast, non-modular cemented systems are said to be more forgiving and show good long-term results. The aim of this study was to investigate the resulting leg axis after implantation of a non-modular cemented rotating hinged knee prosthesis. Furthermore, potential risk factors for the occurrence of malalignment and complications should be identified. METHODS: Between 2005 and 2015, 115 patients could be included in this monocentric retrospective cohort study. All patients underwent primary hinged non-modular cemented total knee arthroplasty. Preoperative and postoperative standardized long radiographs were analysed to determine resulting leg axis. Furthermore, epidemiological and intraoperative data as well as perioperative complications were surveyed. RESULTS: Average leg axis was 5.8° varus preoperatively and 0.6° valgus postoperatively. Considering an axis deviation of 3° as the target corridor, 27% of all cases examined were outside the desired range. 21% cases showed a femoral deviation from the target corridor and 15% showed a tibial deviation. There was a significant relationship between the preoperative mLDFA and the mechanical alignment of the femoral component (R = 0.396, p < 0.001) as well as between the preoperative mMPTA and the mechanical alignment of the tibial component (R = 0.187, p = 0.045). The mean operative duration was 96 min. No periprosthetic fractures were observed within the study cohort. CONCLUSION: The main result of the present work is that a non-modular cemented rotating hinged knee arthroplasty system can reconstruct the mechanical leg axis precisely and comparable to modular cementless and unconstrained total knee prostheses. Component malalignment is primarily dependent upon extraarticular deformity preoperatively. Periprosthetic fracture rates and duration of surgery were lower compared with current literature. LEVEL OF EVIDENCE: Level III: Retrospective cohort study.

8.
Artículo en Inglés | MEDLINE | ID: mdl-38967778

RESUMEN

INTRODUCTION: The treatment option for borderline hip dysplasia (BHD) includes hip arthroscopy and periacetabular osteotomy (PAO). To the present day the controversial discussion remains, which intervention to prefer. Literature reports supporting an educated choice are scare, based on small patient cohorts and do not address the variability of acetabular morphology. Consequently, we intended to report PAO outcomes, from patients diagnosed with BHD, dependent on acetabular morphology, in a large patient cohort and aimed to define risk factors for poor clinical results and patient satisfaction. MATERIALS AND METHODS: A prospective monocentre study was conducted. Patients enrolled underwent PAO for symptomatic BHD (LCEA, 18°-25°). A total of 107 hips were included with 94 complete data sets were available for evaluation with a minimum follow-up of 1 year and a mean follow-up of 2.3 years. The mean age was 31 ± 8.2 years, and 81.3% were female. As the primary outcome measure, we utilized the modified Harris hip score (mHHS) with minimal clinically important change (MCID) of eight to define clinical failure. Results were compared after a comprehensive radiographic assessment distinguishing between lateral deficient vs. anterior/posterolateral deficient acetabular and stable vs. unstable hip joints. RESULTS: Overall, clinical success was achieved in 91.5% of patients and the mHHS improved significantly (52 vs. 84.7, p < 0.001). Eight hips failed to achieve the MCID and four had radiographic signs of overcorrection. Comparing variable joint morphologies, the rate of clinical success was higher in patients with an anterior/posterolateral deficient acetabular covarage compared to lateral deficient acetabular (95.2% vs. 90.4%). tThe highest rate of clinical failure was recorded in unstable hip joints (85.7% vs. 92.5% in stable hips). CONCLUSIONS: This study demonstrates that PAO is an effective means to treat symptomatic BHD with variable acetabular morphologies, achieving a clinical success in 91.5% of all patients. To maintain a high level of safety and patient satisfaction technical accuracy appears crucial.

9.
Knee Surg Sports Traumatol Arthrosc ; 31(4): 1323-1333, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35394135

RESUMEN

PURPOSE: The number of primary total knee arthroplasties (TKA) is expected to rise constantly. For patients and healthcare providers, the early identification of risk factors therefore becomes increasingly fundamental in the context of precision medicine. Others have already investigated the detection of risk factors by conducting literature reviews and applying conventional statistical methods. Since the prediction of events has been moderately accurate, a more comprehensive approach is needed. Machine learning (ML) algorithms have had ample success in many disciplines. However, these methods have not yet had a significant impact in orthopaedic research. The selection of a data source as well as the inclusion of relevant parameters is of utmost importance in this context. In this study, a standardized approach for ML in TKA to predict complications during surgery and an irregular surgery duration using data from two German arthroplasty-specific registries was evaluated. METHODS: The dataset is based on two initiatives of the German Society for Orthopaedics and Orthopaedic Surgery. A problem statement and initial parameters were defined. After screening, cleaning and preparation of these datasets, 864 cases of primary TKA (2016-2019) were gathered. The XGBoost algorithm was chosen and applied with a hyperparameter search, a cross validation and a loss weighting to cope with class imbalance. For final evaluation, several metrics (accuracy, sensitivity, specificity, AUC) were calculated. RESULTS: An accuracy of 92.0%, sensitivity of 34.8%, specificity of 95.8%, and AUC of 78.0% were achieved for predicting complications in primary TKA and 93.4%, 74.0%, 96.3%, and 91.6% for predicting irregular surgery duration, respectively. While traditional statistics (correlation coefficient) could not find any relevant correlation between any two parameters, the feature importance revealed several non-linear outcomes. CONCLUSION: In this study, a feasible ML model to predict outcomes of primary TKA with very promising results was built. Complex correlations between parameters were detected, which could not be recognized by conventional statistical analysis. Arthroplasty-specific data were identified as relevant by the ML model and should be included in future clinical applications. Furthermore, an interdisciplinary interpretation as well as evaluation of the results by a data scientist and an orthopaedic surgeon are of paramount importance. LEVEL OF EVIDENCE: Level IV.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Ortopedia , Humanos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/métodos , Aprendizaje Automático , Medición de Riesgo , Factores de Riesgo
10.
Int J Mol Sci ; 24(16)2023 Aug 13.
Artículo en Inglés | MEDLINE | ID: mdl-37628918

RESUMEN

Previously, we demonstrated in pigs that renal denervation halves glucose release during hypoglycaemia and that a prenatal dexamethasone injection caused increased ACTH and cortisol concentrations as markers of a heightened hypothalamic pituitary adrenal axis (HPAA) during hypoglycaemia. In this study, we investigated the influence of an altered HPAA on renal glucose release during hypoglycaemia. Pigs whose mothers had received two late-gestational dexamethasone injections were subjected to a 75 min hyperinsulinaemic-hypoglycaemic clamp (<3 mmol/L) after unilateral surgical denervation. Para-aminohippurate (PAH) clearance, inulin, sodium excretion and arterio-venous blood glucose difference were measured every fifteen minutes. The statistical analysis was performed with a Wilcoxon signed-rank test. PAH, inulin, the calculated glomerular filtration rate and plasma flow did not change through renal denervation. Urinary sodium excretion increased significantly (p = 0.019). Side-dependent renal net glucose release (SGN) decreased by 25 ± 23% (p = 0.004). At 25 percent, the SGN decrease was only half of that observed in non-HPAA-altered animals in our prior investigation. The current findings may suggest that specimens with an elevated HPAA undergo long-term adaptations to maintain glucose homeostasis. Nonetheless, the decrease in SGN warrants further investigations and potentially caution in performing renal denervation in certain patient groups, such as diabetics at risk of hypoglycaemia.


Asunto(s)
Hipoglucemia , Hipoglucemiantes , Femenino , Animales , Porcinos , Embarazo , Glucosa , Sistema Hipotálamo-Hipofisario , Inulina , Sistema Hipófiso-Suprarrenal , Ácido p-Aminohipúrico , Dexametasona/efectos adversos , Desnervación
11.
Arch Orthop Trauma Surg ; 143(1): 489-493, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35037995

RESUMEN

In total knee arthroplasty (TKA), the aim of achieving a mechanically straight leg axis as well as symmetrical and equally wide gaps has become established as the gold standard in terms of surgical technique. In contrast to TKA unicompartmental knee arthroplasty (UKA) is performed in anteromedial osteoarthritis (AMOA) and does not normally require releases. This raises the hypothesis whether the type of osteoarthritis (AMOA vs. posteromedial osteoarthritis (PMOA)) determines the requirement for soft tissue releases in TKA.In this retrospective study, 114 patients with medial osteoarthritis of the knee who had been treated with a navigated total knee replacement were consecutively included. On the basis of the preoperative lateral radiographs, the patients were divided into two groups: AMOA and PMOA. The incidence and the extent of releases performed were recorded using the navigation records.Patient-specific data (gender, age) did not differ between the groups (NS). Knees with AMOA presented an overall varus alignment of 5.3 ± 3.5°, knees with PMOA 8.0 ± 4.0° (p < 0.001). 30 cases (44%) had to be released in the AMOA group, compared with 33 cases (72%) in the PMOA group (p = 0.004). In the case of medial release, the extension gap increased 3.3 ± 2.4 mm in the AMOA compared to 5.3 ± 3.7 mm in the PMOA group (p = 0.006). The medial flexion gap was released 2.2 ± 2.6 mm in the AMOA and 2.9 ± 3.0 mm in the PMOA group (p = 0.008).To achieve a neutral mechanical alignment, a release has to be performed due to asymmetry of the extension gap more often if PMOA is present than in AMOA. Surgeons should be prepared to perform more frequent and extensive medial releases in PMOA. Higher constrained implants should be available in case of unintended over release in PMOA.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Osteoartritis de la Rodilla/cirugía , Estudios Retrospectivos , Articulación de la Rodilla/cirugía , Rodilla/cirugía , Rango del Movimiento Articular
12.
Arch Orthop Trauma Surg ; 143(8): 5249-5254, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36538161

RESUMEN

INTRODUCTION: Vancomycin powder (VP) is an antibiotic first introduced in pediatric spinal surgery to prevent surgical site infections (SSI). Recently its topical application was expanded to total hip and knee arthroplasty (THA, TKA) and anterior cruciate ligament reconstruction (ACLR). Toxicity to cartilage is the subject of current research. The aim of this study was to prove the hypothesis that topical application of VP in TKA does not result in a degeneration of patella cartilage. We propagate that the conversion rate for secondary patella resurfacing is not influenced by its use. MATERIALS AND METHODS: Between 2014 and 2021, 4292 joints were included in this monocentric retrospective cohort study. All patients underwent TKA without primary patella resurfacing. After a change of the procedure in the hospital, one group (VPG) was administered VP intraoperatively. The other group (nVPG) received no VP during surgery (nVPG). The remaining perioperative procedure was constant over the investigation period. Conversion rates for secondary patella resurfacing for both groups were determined without making distinctions in the indication. A second cohort was composed of patients presenting for follow-up examination 12 months after TKA and included 210 joints. Retrospective radiographic evaluations were performed preoperatively, before discharge and at follow-up examination. Patella axial radiographs were analyzed for patella tracking (lateral patellar tilt, patellar displacement) and patella degeneration (Sperner classification, patellofemoral joint space). RESULTS: There was no significant difference in the conversion rate for secondary patella resurfacing (4.24% VPG, 4.97% nVPG). Patella tracking and patella degeneration did not differ significantly between both groups. CONCLUSIONS: The topical application of VP does not influence the conversion rate for secondary patella resurfacing. Moreover, it does not result in a degeneration of patella cartilage in TK. LEVEL OF EVIDENCE: Retrospective case series, Level III.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Humanos , Niño , Artroplastia de Reemplazo de Rodilla/métodos , Rótula/cirugía , Estudios Retrospectivos , Vancomicina , Polvos , Articulación de la Rodilla/cirugía , Resultado del Tratamiento , Osteoartritis de la Rodilla/cirugía
13.
Arch Orthop Trauma Surg ; 143(6): 3495-3503, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35943586

RESUMEN

INTRODUCTION: Periprosthetic joint infection (PJI) after total hip arthroplasty (THA) remains a serious complication in orthopaedic surgery. C-reactive protein (CRP) is widely used as a marker to screen for inflammatory complications. The early postoperative course is well known, but knowledge about the predictive value of CRP in the first 6 postoperative days for detecting an acute postoperative PJI is lacking. METHODS: We retrospectively analyzed the inpatient course of CRP of all primary THA and THA with acute PJI within 28 days in our hospital from 2013 to 2021. A receiver-operating curve (ROC) analysis was performed and the best CRP threshold for detecting an acute PJI based on Youden's-index was calculated and an area-under-the curve (AUC) analysis of the threshold was performed. RESULTS: 33 of 7042 patients included had an acute PJI within 28 days. Patients with acute PJI were older, had a higher BMI and longer operation time and suffered more often from diabetes mellitus. A preoperatively elevated CRP was a risk factor for PJI. CRP was significantly higher in the PJI group on postoperative days 3 and 5. Threshold values were calculated to be 152 mg/l on day 3 and 73 mg/l on day 5. However, these values had a low sensitivity (75%, 76%) and specificity (67%, 61%). CONCLUSION: Especially considering the decreasing length of stay after THA, the question of the usefulness of regular inpatient CRP checks arises. AUC analysis of the ROC showed a poor diagnostic accuracy in almost all cases. Only the dynamic analysis of the maximum CRP value to the lowest CRP value with a decrease of 102.7 mg/l showed a fair accuracy. This calls into question the clinical relevance of CRP in the first postoperative week for detection of acute postoperative PJI.


Asunto(s)
Artritis Infecciosa , Artroplastia de Reemplazo de Cadera , Infecciones Relacionadas con Prótesis , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Proteína C-Reactiva/análisis , Estudios Retrospectivos , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/etiología , Infecciones Relacionadas con Prótesis/cirugía , Factores de Riesgo , Artritis Infecciosa/cirugía , Biomarcadores , Sensibilidad y Especificidad , Sedimentación Sanguínea
14.
Arch Orthop Trauma Surg ; 143(1): 469-479, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35930052

RESUMEN

INTRODUCTION: While re-revision total knee arthroplasty (ReRTKA) steadily increases, the ease and bone-sparing removal of RTKA implants is gaining more and more in importance. Biomechanical data suggest that cemented conical stems can be removed significantly easier than cylindrical stems. However, no clinical evidence exists supporting this observation. Aim of this study was to compare the revisability and need for osteotomy (OT) between removals of well-fixed cemented conical vs. cylindrical RTKA stems. MATERIALS AND METHODS: 55 removals of well-fixed full-cemented RTKA stems (29 knees) performed between 2016 and 2018 were retrospectively analyzed. Main outcome variables were: bone loss, fractures, osteotomy incidence, surgery duration, early postoperative complications (EPC), hemoglobin drop and blood transfusion. SPSS was used for the statistical analysis. RESULTS: 44.8% were conical, 48.3% cylindrical, and 6.9% combined stem designs. Causes for re-revision were PJI (75.9%), malposition (17.2%) and persistent pain (6.9%). 10 stem removals (18.2%) required an OT (four femoral, six tibial): eight stems (14.5%) had cylindrical and two (3.6%) conical designs (P = 0.041). Fractures were noted solely in removals without OT (11.1% vs. 0%,). There was a tendency to more bone loss in cylindrical stem revisions (53.8% vs. 32%, P = 0.24). A longer overall surgery time was observed in revisions of cylindrical stems (+ 37 min, P = 0.05). There was higher hemoglobin drop and need for blood transfusion in revisions of cylindrical stems or after OT but without reaching statistical significance. The EPC rates were slightly higher in ReRTKA on cylindrical stems (P = 0.28). CONCLUSION: Well-fixed cemented conical stems may be revision friendlier with less demands on OT and shorter overall surgery time than cemented cylindrical stems.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Fracturas Óseas , Prótesis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Fracturas Óseas/complicaciones , Hemoglobinas , Prótesis de la Rodilla/efectos adversos , Osteotomía/efectos adversos , Diseño de Prótesis , Falla de Prótesis , Reoperación , Estudios Retrospectivos
15.
Arch Orthop Trauma Surg ; 143(3): 1549-1569, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36450936

RESUMEN

INTRODUCTION: Revision total knee arthroplasty (RTKA) has been increasing continuously. The results of RTKA still remain unsatisfactory. Failure patterns and risk factors in RTKA were thoroughly analyzed, with periprosthetic joint infections (PJI) and aseptic loosening remaining at the forefront of re-revision (ReRTKA) causes. While there is evidence that stem profile impacts the revisability of cemented implants, its association with the modes of RTKA failure is unknown. METHODS: 50 consecutive ReRTKA performed in a single orthopedic center during 2016-2017 were retrospectively analyzed. The cases were stratified according to age, sex, number of preexisting revisions, fixation technique, stem design and causes of re-revision. All explanted implants with conical vs. cylindrical stem profiles were compared. RESULTS: Mean age was 67 ± 11.5, and 54% were females. 72% of the cases had ≥ 3 previous revisions. 88% were full-cemented, 3% hybrid and 9% press-fit stems. 36% of the RTKA had conical, 58% cylindrical and 6% combined stem profiles. 92% of the RTKA components were removed. Removal causes were: PJI (52.2%), aseptic loosening (34.8%), implant malposition (9.8%), painful knee (1.1%) and instability (2.2%). While the overall RTKA failure patterns were equally distributed between conical and cylindrical stems, subgroup analysis of only cemented ReRTKA revealed a higher incidence of aseptic loosening within cylindrical stem profiles (46.7% vs. 25.7%, P = 0.05). CONCLUSION: Stem profile may have an impact on the process of aseptic loosening in cemented non-metaphyseal engaging RTKA, with cylindrical designs tending to worse outcomes than conical designs. Large cohort studies could provide more clarity on current observation.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Femenino , Humanos , Persona de Mediana Edad , Anciano , Masculino , Artroplastia de Reemplazo de Rodilla/efectos adversos , Prótesis de la Rodilla/efectos adversos , Estudios Retrospectivos , Falla de Prótesis , Reoperación/métodos , Diseño de Prótesis
16.
Arch Orthop Trauma Surg ; 143(9): 5671-5676, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37099164

RESUMEN

PURPOSE: Various anatomical landmarks have become established in radiography for the assessment of cup positioning after total hip arthroplasty (THA). The most important one is Koehler's teardrop figure (KTF). However, there is a lack of data on the validity of this landmark, which is widely used clinically for assessing the centre of rotation of the hip. METHOD: A retrospective measurement of the lateral and cranial distance of the KTF to the centre of hip rotation was performed on the basis of 250 X-ray images of patients who had undergone THA. In addition, the dependence of these distances on pelvic tilt was determined in 16 patients by means of virtual X-ray projections based on pelvic CTs. RESULTS: It was shown that the distance of the KTF from the centre of hip rotation in the horizontal plane is gender-dependent (men: 42.8 ± 6.0 mm vs. women: 37.4 ± 4.7 mm; p < 0.001) and age-dependent (Pearson correlation - 0.114; p < 0.05). Furthermore, the vertical and horizontal distances are subject to variation depending on height (Pearson correlation 0.14; p < 0.05 and 0.40; p < 0.001, respectively) and weight (Pearson correlation 0.158; p < 0.05). The distance between the KTF and the centre of hip rotation varies slightly depending on pelvic tilt. CONCLUSION: The KTF is not a sufficiently valid landmark for assessing the centre of rotation after THA. It is influenced by many different disturbance variables. However, it is largely robust against changes in pelvic tilt, so that it can be used as a reference point when comparing different intraindividual radiographs to assess the change in the centre of rotation due to implantation or to detect cup migration.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Masculino , Humanos , Femenino , Artroplastia de Reemplazo de Cadera/métodos , Estudios Retrospectivos , Rotación , Radiografía , Pelvis
17.
Knee Surg Sports Traumatol Arthrosc ; 30(8): 2824-2837, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34389876

RESUMEN

PURPOSE: The fixation of revision total knee arthroplasties (rTKA) tends to be difficult, leading to a reduction in implant survival. One option for achieving a more stable anchorage is to use metaphyseal cones and sleeves. The objective of the present paper is to provide a current comparative meta-analysis on survival and clinical results of cones vs. sleeves, with a differentiation between the short- and long-term outcome. METHODS: A search of the literature was conducted systematically to include original papers from 2010 to June 2021. The following parameters were taken into account: revision for aseptic loosening, revision for any reason, periprosthetic joint infections (PJI), KSS as well as KSFS. Studies with a mean follow-up of at least 60 months were defined to be long-term follow-up studies (LT). All other studies were included in the short-term (ST) study analysis. A pooled incidence was used as a summary statistic using a random intercept logistic regression model. RESULTS: The present meta-analysis included 43 publications with 3008 rTKA. Of these, 23 publications with 1911 cases were allocated to the sleeve group (SG) and 20 papers with 1097 cases to the cone group (CG). CG showed overall numerically higher complication rates in short- and long-term follow-up, compared with SG. Aseptic loosening occurred at a rate of 0.4% in SG (LT) and 4.1% in CG (LT) (p = 0.09). Periprosthetic joint infection (PJI) was more frequent in the cone group (7% in ST and 11.7% in LT) than in the sleeve group (3.4% in ST and 4.9% in LT, p = 0.02 both). The total revision rate was 5.5% in SG (LT) and 14.4% in CG (LT) (p = 0.12). The clinical scores were also comparable between the two groups. Hinged prothesis were used more frequent in the cone group (ST p < 0.001; LT p = 0.10), whereas CC type protheses were used more frequently in the sleeve group (ST p < 0.001; LT p < 0.11). CONCLUSIONS: This meta-analysis takes into account the longest follow-up periods covered to date. Both cones and sleeves represent a reliable fixation method in the case of severe bone loss in rTKA, although the higher rate of PJI after cone fixation remains a source of concern. A metaphyseal fixation of hinged implants should be taken into account. LEVEL OF EVIDENCE: II (meta-analysis).


Asunto(s)
Artritis Infecciosa , Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Artritis Infecciosa/cirugía , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/métodos , Humanos , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla/efectos adversos , Diseño de Prótesis , Reoperación/métodos , Estudios Retrospectivos
18.
J Orthop Sci ; 27(1): 146-152, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33309404

RESUMEN

BACKGROUND: Posttraumatic maltorsion and implant failure after closed reduction of proximal femoral fractures remain a cause of concern. Although the reproducibility of torsion measuring techniques on CT for femoral shaft fractures has been thoroughly analyzed, little is known about the trochanteric fractures. Apart from the well-known CT limitations, posttraumatic alteration of bony landmarks makes torsional assessment even more challenging. Main goal of this study was to examine the reliability of different CT techniques on trochanteric femoral fractures after closed nail fixation. Secondary goal was to see whether the measurements within the examined population were influenced by the fracture type and patient age or BMI. METHODS: 20 cases (AO.31-A1 or -A2) were retrospectively examined. Six established CT techniques for torsional assessment were performed from three different investigators twice at different time points. The intraclass correlation coefficient (ICC for 95% CI) was used to analyze the interobserver and intraobserver reliability. RESULTS: The Hernandez method (0.986) followed by the Jend method (0.982) by a mean difference of <1° showed the highest reliability. Although increasing fracture complexity from A1 to A2 led to an overall worsening of the measurement precision, the Hernandez and Jend techniques revealed a very good consistency. Within the examined population, age and BMI had no impact on the precision of the measurements. CONCLUSIONS: The Hernandez and Jend methods represent reliable alternatives for torsional assessment of trochanteric femur fractures treated with closed nail fixation when compared to the other measurement techniques here involved. Documentation of the torsion measuring method used in each case constitutes an essential element of the radiological reports.


Asunto(s)
Fracturas del Fémur , Fracturas de Cadera , Clavos Ortopédicos , Fracturas del Fémur/diagnóstico por imagen , Fracturas del Fémur/cirugía , Fracturas de Cadera/diagnóstico por imagen , Fracturas de Cadera/cirugía , Humanos , Reproducibilidad de los Resultados , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
19.
Int Orthop ; 46(4): 717-722, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34581866

RESUMEN

PURPOSE: The cementless implantation of hip replacement cups may be performed with and without the additional use of acetabular screws. If the surgeon uses screws or not depends on variable factors. In general, the use of screws is intended to increase the primary stability of the cup. Whether screws increase the initial stability of the cup construct, or even reduce it in part, is the subject of considerable debate in the literature. It is also unclear whether the additional screws lead to increased wear or increased periacetabular osteolysis over the long-term course. METHODS: Two hundred eleven patients from a previous study with a minimum follow-up of 10.7 years were included. Of these, 68 patients with 82 total hip arthroplasties (THA) were given clinical and radiological follow-up examinations. Of these, 52 had been fitted without screws and 30 with screws. On the basis of radiographs, annual wear and osteolysis were quantified. The clinical results were recorded by means of VAS, HHS, and WOMAC scores. RESULTS: Significantly more periacetabular osteolysis was found if additive acetabular screws had been used. No difference was found in relation to the volumetric wear per year. Likewise, no difference was found with regard to the clinical scores. CONCLUSIONS: The use of additive acetabular screws leads to increased osteolysis in the periacetabular bone stock. Insofar as the primary stability of the cementless cup construct allows it, no additional acetabular screws should be used.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Osteólisis , Acetábulo/diagnóstico por imagen , Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Tornillos Óseos/efectos adversos , Estudios de Seguimiento , Prótesis de Cadera/efectos adversos , Humanos , Osteólisis/epidemiología , Osteólisis/etiología , Osteólisis/cirugía , Diseño de Prótesis , Falla de Prótesis
20.
Int Orthop ; 46(11): 2547-2552, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35994066

RESUMEN

PURPOSE: When revising acetabular cups, it is often necessary to provide additional stabilisation with screws. In extensive defect situations, the placement of screws caudally in the ischium and/or pubis is biomechanically advantageous. Especially after multiple revision operations, the surgeon is confronted with a reduced bone stock and unclear or altered anatomy. In addition, screw placement caudally is associated with greater risk. Therefore, the present study aims to identify and define safe zones for the placement of caudal acetabular screws. METHODS: Forty-three complete CT datasets were used for the evaluation. Sixty-three distinctive 3D points representing bone landmark of interests were defined. The coordinates of these points were then used to calculate all the parameters. For simplified visualisation and intra-operative reproducibility, an analogue clock was used, with 12 o'clock indicating cranial and 6 o'clock caudal. RESULTS: A consistent accumulation was found at around 4.5 ± 0.3 hours for the ischium and 7.9 ± 0.3 hours for the pubic bone. CONCLUSIONS: The anatomy of the ischium and pubis is sufficiently constant to allow the positioning of screws in a standardised way. The interindividual variation is low - regardless of gender - so that the values determined can be used to position screws safely in the ischium and pubis. The values determined can provide the surgeon with additional orientation intra-operatively when placing caudal acetabular screws.


Asunto(s)
Isquion , Hueso Púbico , Acetábulo/diagnóstico por imagen , Acetábulo/cirugía , Tornillos Óseos , Humanos , Isquion/diagnóstico por imagen , Isquion/cirugía , Hueso Púbico/diagnóstico por imagen , Hueso Púbico/cirugía , Reoperación , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA