Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Crit Care Med ; 42(6): e451-60, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24705570

RESUMEN

OBJECTIVE: The Acute Respiratory Distress Syndrome Network protocol recommends limiting tidal volume and plateau pressure; it also recommends increasing respiratory rate to prevent hypercapnia. We tested a strategy that combines the low tidal volume with lower respiratory rates and minimally invasive CO2 removal. SUBJECTS: Ten lung-damaged pigs (instilled hydrochloride). INTERVENTIONS: Two conditions randomly applied in a crossover fashion: the Acute Respiratory Distress Syndrome Network protocol and the Acute Respiratory Distress Syndrome Network protocol plus lower respiratory rate plus minimally invasive Co2 removal. A similar arterial Co2 partial pressure was targeted in the two conditions. MEASUREMENTS AND MAIN RESULTS: Physiological parameters, computed tomography scans, plasma and bronchoalveolar lavage concentrations of interleukin-1ß, interleukin-6, interleukin-8, interleukin-10, interleukin-18, and tumor necrosis factor-α. During the lower respiratory rate condition, respiratory rate was reduced from 30.5 ± 3.8 to 14.2 ± 3.5 (p < 0.01) breaths/min and minute ventilation from 10.4 ± 1.6 to 4.9 ± 1.7 L/min (p < 0.01). The extracorporeal device removed 38.9% ± 6.1% (79.9 ± 18.4 mL/min) of CO2 production. During the lower respiratory rate condition, interleukin-6, interleukin-8, and tumor necrosis factor-α concentrations were significantly lower in plasma; interleukin-6 and tumor necrosis factor-α concentrations were lower in bronchoalveolar lavage, whereas the concentrations of the other cytokines remained unchanged. CONCLUSION: The strategy of lower respiratory rate plus minimally invasive extracorporeal CO2 removal was feasible and safe and, as compared with the Acute Respiratory Distress Syndrome Network protocol, reduced the concentrations of some, but not all, of the tested cytokines without affecting respiratory mechanics, gas exchange, and hemodynamics.


Asunto(s)
Citocinas/análisis , Oxigenación por Membrana Extracorpórea/métodos , Pulmón/fisiopatología , Respiración con Presión Positiva/métodos , Síndrome de Dificultad Respiratoria/terapia , Lesión Pulmonar Inducida por Ventilación Mecánica/prevención & control , Animales , Líquido del Lavado Bronquioalveolar , Modelos Animales de Enfermedad , Oxigenación por Membrana Extracorpórea/instrumentación , Estudios de Factibilidad , Femenino , Hemodinámica , Pulmón/metabolismo , Respiración con Presión Positiva/efectos adversos , Respiración con Presión Positiva/normas , Guías de Práctica Clínica como Asunto , Síndrome de Dificultad Respiratoria/inducido químicamente , Síndrome de Dificultad Respiratoria/metabolismo , Mecánica Respiratoria , Frecuencia Respiratoria , Porcinos , Volumen de Ventilación Pulmonar
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA