Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Eur Heart J ; 45(21): 1904-1916, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38554125

RESUMEN

BACKGROUND AND AIMS: There is significant potential to streamline the clinical pathway for patients undergoing transcatheter aortic valve implantation (TAVI). The purpose of this study was to evaluate the effect of implementing BENCHMARK best practices on the efficiency and safety of TAVI in 28 sites in 7 European countries. METHODS: This was a study of patients with severe symptomatic aortic stenosis (AS) undergoing TAVI with balloon-expandable valves before and after implementation of BENCHMARK best practices. Principal objectives were to reduce hospital length of stay (LoS) and duration of intensive care stay. Secondary objective was to document patient safety. RESULTS: Between January 2020 and March 2023, 897 patients were documented prior to and 1491 patients after the implementation of BENCHMARK practices. Patient characteristics were consistent with a known older TAVI population and only minor differences. Mean LoS was reduced from 7.7 ± 7.0 to 5.8 ± 5.6 days (median 6 vs. 4 days; P < .001). Duration of intensive care was reduced from 1.8 to 1.3 days (median 1.1 vs. 0.9 days; P < .001). Adoption of peri-procedure best practices led to increased use of local anaesthesia (96.1% vs. 84.3%; P < .001) and decreased procedure (median 47 vs. 60 min; P < .001) and intervention times (85 vs. 95 min; P < .001). Thirty-day patient safety did not appear to be compromised with no differences in all-cause mortality (0.6% in both groups combined), stroke/transient ischaemic attack (1.4%), life-threatening bleeding (1.3%), stage 2/3 acute kidney injury (0.7%), and valve-related readmission (1.2%). CONCLUSIONS: Broad implementation of BENCHMARK practices contributes to improving efficiency of TAVI pathway reducing LoS and costs without compromising patient safety.


Asunto(s)
Estenosis de la Válvula Aórtica , Benchmarking , Tiempo de Internación , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/cirugía , Masculino , Femenino , Anciano de 80 o más Años , Tiempo de Internación/estadística & datos numéricos , Anciano , Vías Clínicas , Europa (Continente)/epidemiología , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/prevención & control , Seguridad del Paciente
2.
Cardiology ; 149(5): 487-494, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38527430

RESUMEN

INTRODUCTION: The role of balloon aortic valvuloplasty (BAV) in the era of transcatheter aortic valve replacement remains a topic of debate. We sought to study the safety and feasibility of combined BAV and percutaneous coronary intervention (BAV-PCI). METHODS: Between November 2009 and July 2020, all patients undergoing BAV were identified and divided into three groups: combined BAV-PCI (group A), BAV with significant unrevascularised CAD (group B), and BAV without significant CAD (group C). Procedural outcomes and 30-day and one-year mortality were compared. RESULTS: A total of 264 patients were studied (n = 84, 93, and 87 patients in groups A, B, and C, respectively). The STS score was 10.2 ± 8, 13.3 ± 19, and 8.1 ± 7, p = 0.026, in groups A, B, and C, respectively. VARC-3 adjudicated complications were similar among groups (11%, 13%, and 5%, respectively, p = 0.168, respectively). Thirty-day and one-year mortality were 9.8% (n = 26) and 32% (n = 86) of the entire cohort. The differences among groups did not reach statistical significance. Using univariate Cox regression analysis, group B patients were at higher risk of dying compared to group A patients (HR 1.58, 95% CI: 1.11-2.25, p = 0.010). With multivariate Cox regression analysis, the predictors of mortality were STS score, cardiogenic shock, mode of presentation, and lack of subsequent definitive valve intervention. CONCLUSION: In high-risk patients with aortic valve stenosis, combined BAV-PCI is safe and feasible with comparable outcomes to BAV with and without significant CAD.


Asunto(s)
Estenosis de la Válvula Aórtica , Valvuloplastia con Balón , Intervención Coronaria Percutánea , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Masculino , Femenino , Valvuloplastia con Balón/métodos , Valvuloplastia con Balón/efectos adversos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Anciano de 80 o más Años , Anciano , Estudios Retrospectivos , Estudios de Factibilidad , Resultado del Tratamiento , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/cirugía
3.
Crit Care Nurs Clin North Am ; 34(2): 215-231, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35660235

RESUMEN

Transcatheter aortic valve replacement (TAVR) is an established therapy for the treatment of severe aortic stenosis. The evolution of technology and procedural approaches has facilitated the development of streamlined clinical pathways to optimize patient care and improve outcomes. The revision of historical practices and the adoption of contemporary best practices throughout patients' journey from referral to discharge create opportunities to drive quality improvement. Nursing expertise and leadership are essential to recalibrate preprocedure, periprocedure, and postprocedure practice to transform the way we care for TAVR, achieve excellent outcomes, and promote high-performing health services for the treatment of valvular heart disease.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Estenosis de la Válvula Aórtica/cirugía , Benchmarking , Humanos , Tiempo de Internación , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
4.
Clin Cardiol ; 44(10): 1344-1353, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34499383

RESUMEN

BACKGROUND: The use of transcatheter aortic valve implantation (TAVI) for treating aortic stenosis (AS) has increased exponentially in recent years. Despite the availability of clinical practice guidelines for the management of valvular heart disease, disparities in quality of care (QoC) for TAVI patients remain widespread across Europe. Tailored QoC measures will help to reduce resource utilization and improve patient outcomes without compromising patient safety. Using a clear set of QoC measures, the BENCHMARK registry aims to document the progress that can be achieved if such tailored QoC measures are implemented. METHODS: The BENCHMARK registry (BENCHMARK) is a non-interventional, multicenter registry in patients with severe symptomatic AS undergoing TAVI with a 1- and 12-months follow-up. BENCHMARK will be conducted at 30 centers across Europe and will enroll a total of 2400 consecutive TAVI patients. Patients suffering from severe symptomatic AS who undergo TAVI with a balloon-expandable transcatheter aortic valve will be included. The registry will comprise four phases: (1) a retrospective baseline evaluation phase; (2) an education phase; (3) an implementation phase; and (4) a prospective effect documentation phase (prospective phase). The registry's primary objectives are to reduce the length of hospital stay and accelerate the post-procedural patient recovery pathway, but without compromising safety. The study started in April 2021 and has an estimated completion date of May 2023. DISCUSSION: BENCHMARK will establish QoC measures to reduce resource utilization, intensive care unit bed occupancy, and overall length of hospitalization with uncompromised patient safety post-TAVI (ClinicalTrials.gov Identifier: NCT04579445).


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Benchmarking , Europa (Continente) , Humanos , Estudios Prospectivos , Sistema de Registros , Estudios Retrospectivos , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
5.
Eur J Cardiovasc Nurs ; 19(6): 537-544, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32498556

RESUMEN

The COVID-19 pandemic continues to significantly impact the treatment of people living with aortic stenosis, and access to transcatheter aortic valve implantation. Transcatheter aortic valve implantation (TAVI) programmes require unique coordinated processes that are currently experiencing multiple disruptions and are guided by rapidly evolving protocols. We present a series of recommendations for TAVI programmes to adapt to the new demands, based on recent evidence and the international expertise of nurse leaders and collaborators in this field. Although recommended in most guidelines, the uptake of the role of the TAVI programme nurse is uneven across international regions. COVID-19 is further highlighting why a nurse-led central point of coordination and communication is a vital asset for patients and programmes. We propose an alternative streamlined evaluation pathway to minimize patients' pre-procedure exposure to the hospital environment while ensuring appropriate treatment decision and shared decision-making. The competing demands created by COVID-19 require vigilant wait list management, with risk stratification, telephone surveillance and optimized triage and prioritization. A minimalist approach with close scrutiny of all parts of the procedure has become an imperative to avoid any complications and ensure patients' accelerated recovery. Lastly, we outline a nurse-led protocol of rapid mobilization and reconditioning as an effective strategy to facilitate safe next-day discharge home. As the pandemic abates, TAVI programmes must facilitate access to care without compromising patient safety, enable hospitals to manage the competing demands created by COVID-19 and establish new processes to support patients living with valvular heart disease.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Betacoronavirus , Infecciones por Coronavirus , Pandemias , Neumonía Viral , Reemplazo de la Válvula Aórtica Transcatéter , Estenosis de la Válvula Aórtica/cirugía , COVID-19 , Humanos , Alta del Paciente , Seguridad del Paciente , Guías de Práctica Clínica como Asunto , SARS-CoV-2 , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA