Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 79
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Ear Hear ; 43(5): 1593-1596, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35234171

RESUMEN

OBJECTIVES: The primary objective was to estimate the prevalence of somatosensory tinnitus (ST) among Veterans with tinnitus. DESIGN: Three hundred four Veterans with tinnitus were phone screened for ST by performing and reporting on a series of head/neck/jaw maneuvers. A random sample of 12 individuals who screened positive and five who screened negative attended an in-person visit to confirm the presence/absence of ST. RESULTS: Of the 304 Veterans, 12 could not complete the screening maneuvers, 205 screened positive, and 87 screened negative. A Bayesian estimator that combines phone screening and in-person exam results establishes the prevalence of ST among Veterans with tinnitus at 56% with a 90% Bayesian confidence interval of 45% to 65%. CONCLUSIONS: At least half of Veterans with tinnitus have ST, suggesting that a sizable at-need population exists. Treatment addressing the biomechanical component has the potential to improve tinnitus symptoms.


Asunto(s)
Acúfeno , Veteranos , Teorema de Bayes , Humanos , Cuello , Prevalencia , Acúfeno/epidemiología , Acúfeno/terapia
2.
J Acoust Soc Am ; 151(1): 561, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-35105019

RESUMEN

Aging, noise exposure, and ototoxic medications lead to cochlear synapse loss in animal models. As cochlear function is highly conserved across mammalian species, synaptopathy likely occurs in humans as well. Synaptopathy is predicted to result in perceptual deficits including tinnitus, hyperacusis, and difficulty understanding speech-in-noise. The lack of a method for diagnosing synaptopathy in living humans hinders studies designed to determine if noise-induced synaptopathy occurs in humans, identify the perceptual consequences of synaptopathy, or test potential drug treatments. Several physiological measures are sensitive to synaptopathy in animal models including auditory brainstem response (ABR) wave I amplitude. However, it is unclear how to translate these measures to synaptopathy diagnosis in humans. This work demonstrates how a human computational model of the auditory periphery, which can predict ABR waveforms and distortion product otoacoustic emissions (DPOAEs), can be used to predict synaptic loss in individual human participants based on their measured DPOAE levels and ABR wave I amplitudes. Lower predicted synapse numbers were associated with advancing age, higher noise exposure history, increased likelihood of tinnitus, and poorer speech-in-noise perception. These findings demonstrate the utility of this modeling approach in predicting synapse counts from physiological data in individual human subjects.


Asunto(s)
Pérdida Auditiva Provocada por Ruido , Animales , Umbral Auditivo , Cóclea , Simulación por Computador , Potenciales Evocados Auditivos del Tronco Encefálico/fisiología , Humanos , Emisiones Otoacústicas Espontáneas/fisiología , Sinapsis
3.
Int J Audiol ; 61(12): 1035-1044, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-34851208

RESUMEN

OBJECTIVE: Compare the relative efficacy of DesyncraTM and Cognitive Behavioural Therapy (CBT). DESIGN AND STUDY SAMPLE: Sixty-one participants were randomly assigned to receive either DesyncraTM (n = 29) or CBT (n = 32). Randomisation included stratification regarding current hearing aid (HA) use. Depending on group assignment, participants attended approximately 7-12 visits. Tinnitus distress was measured using the Tinnitus Questionnaire (TQ). RESULTS: Mean TQ scores decreased post-baseline from 5-15 points across treatment arms and strata. Model-based findings for the no-HA stratum showed a difference of -2.0 TQ points favouring Desyncra at 24-weeks, with a 90% posterior interval varying from -5.4 points favouring Desyncra to 0.8 TQ points favouring CBT. For the HA stratum, results show a difference of -1.0 TQ points favouring Desyncra, with a 90% posterior interval ranging from -4.7 points favouring Desyncra to 2.9 points favouring CBT. CONCLUSIONS: The difference between Desyncra and CBT on average showed greater improvement with Desyncra in the no-HA stratum by about 2 TQ points. To the extent that the study sample represents a clinical population and recognising the assumptions in the design and analysis, these results suggest Desyncra is just as effective or more so than CBT in reducing tinnitus distress.


Asunto(s)
Terapia Cognitivo-Conductual , Audífonos , Acúfeno , Humanos , Acúfeno/terapia , Acúfeno/psicología , Resultado del Tratamiento , Terapia Cognitivo-Conductual/métodos , Encuestas y Cuestionarios
4.
Ear Hear ; 42(5): 1163-1172, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33974789

RESUMEN

OBJECTIVES: Auditory impairments, particularly those resulting from hazardous occupational noise exposures, are pressing concerns for the US Departments of Defense (DoD) and Veterans Affairs (VA). However, to date, no studies have estimated the rate of hearing threshold change that occurs during service or how changes may vary by military occupation. Hearing threshold changes during military service have historically been reported as the proportion of Service members demonstrating a significant threshold shift. This approach does not capture the rate of the hearing threshold change or the specific audiometric frequencies impacted. Determining the rate of hearing threshold change, and factors that affect the rate of change, is important to elucidate the impact of military service on hearing and to guide prevention strategies and subsequent hearing health care. Our primary objective was to estimate the annual rate of hearing threshold change during military service as a consequence of military occupational noise exposure ranking. DESIGN: We linked audiometric data, collected from military personnel as part of a DoD hearing conservation program, to data describing demographic and military-service characteristics obtained from individuals enrolled in the Noise Outcomes In Service members Epidemiology Study. The analytic cohort included Veterans who enlisted in military service after September 2001 (n = 246). We examined the longitudinal association between military occupations categorized as having a low, moderate, or high noise exposure ranking and pure-tone hearing thresholds (500 to 6000 Hz) using a hierarchical linear model. The average annual rate of hearing threshold change and their 95% confidence intervals were estimated by service branch, military occupational noise exposure ranking, and audiometric test frequency. RESULTS: On average, hearing threshold change ranged between -0.5 and 1.1 dB/year and changes over time varied by service branch, audiometric test frequency, and military occupation noise ranking. Generally, higher test frequencies (3000 to 6000 Hz) and military occupations with moderate or high noise exposure rankings had the greatest average annual rates of hearing threshold change; however, no dose-response relationship was observed. Among Marine Corps personnel, those exposed to occupations with high noise rankings demonstrated the greatest average annual rate of change (1.1 dB/year at 6000 Hz). Army personnel exposed to occupations with moderate noise rankings demonstrated the greatest average annual rate of change (0.6 dB/year at 6000 Hz). CONCLUSIONS: This study (1) demonstrates the unique use of DoD hearing conservation program data, (2) is the first analysis of hearing threshold changes over time using such data, and (3) adds to the limited literature on longitudinal changes in hearing. The difference in hearing threshold changes across military branches is likely indicative of their varying noise exposures, hearing protection device use and enforcement, and surveillance practices. Results suggest Marine Corps and Army personnel are at risk for hearing threshold changes and that, among Army personnel, this is most pronounced among those exposed to moderate levels of occupational noise exposure. Estimates of the rate of hearing threshold change by frequency and factors that impact hearing are useful to inform the DoD's efforts to protect the hearing of their Service members and to the Veterans Affairs's efforts to identify and rehabilitate those most likely to experience hearing threshold change.


Asunto(s)
Pérdida Auditiva Provocada por Ruido , Personal Militar , Ruido en el Ambiente de Trabajo , Exposición Profesional , Audiometría de Tonos Puros , Umbral Auditivo , Audición , Pérdida Auditiva Provocada por Ruido/epidemiología , Pérdida Auditiva Provocada por Ruido/etiología , Humanos , Ruido en el Ambiente de Trabajo/efectos adversos
5.
Ear Hear ; 41(2): 239-253, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-29280917

RESUMEN

OBJECTIVE: Distortion-product otoacoustic emissions (DPOAEs) provide a rapid, noninvasive measure of outer hair cell damage associated with chemotherapy and are a key component of pediatric ototoxicity monitoring. Serial monitoring of DPOAE levels in reference to baseline measures is one method for detecting ototoxic damage. Interpreting DPOAE findings in this context requires that test-retest differences be considered in relation to normal variability, data which are lacking in children. This study sought to (1) characterize normal test-retest variability in DPOAE level over the long time periods reflective of pediatric chemotherapy regimens for a variety of childhood ages and f2 primary frequencies using common clinical instrumentation and stimulus parameters; (2) develop level-shift reference intervals; and (3) account for any age-related change in DPOAE level or measurement error that may occur as the auditory system undergoes maturational change early in life. DESIGN: Serial DPOAE measurements were obtained in 38 healthy children (25 females and 13 males) with normal hearing and ranging in age from one month to 10 years at the initial (baseline) visit. On average, children were tested 5.2 times over an observation period of 6.5 months. Data were collected in the form of DP grams, in which DPOAE level was measured for f2 ranging from 1.4 to 10 kHz, using a fixed f2/f1 ratio of 1.22 and stimulus level of 65/55 dB SPL for L1/L2. Age effects on DPOAE level and measurement error were estimated using Bayesian regression of the longitudinal data. The raw and model-based distribution of DPOAE test-retest differences were characterized using means and standard error of the measurement for several ages and f2's. RESULTS: DPOAE test-retest differences for the children in this study are at the high end of those previously observed in adults, as reflected in the associated shift reference intervals. Further, although we observe substantial child-specific variation in DPOAE level, the pattern of age-related changes is highly consistent across children. Across a wide range of f2's, DPOAE level decreases by 3 to 4 dB from 1 to 13 months of age followed by a more gradual decline of <1 dB/year. An f2 of 6 kHz shows the smallest decrease during the early rapid maturation period. DPOAE measurement error is fairly constant with age. It is 3 to 4 dB at most f2's and is greater (indicating poorer reliability) at 1.5, 8, and 10 kHz. CONCLUSIONS: DPOAE level decreases with childhood age, with the greatest changes observed in the first year of life. Maturational effects during infancy and greater measurement error at very low and high f2's affect test-retest variability in children. An f2 of 6 kHz shows minimal maturation and measurement error, suggesting it may be an optimal sentinel frequency for ototoxicity monitoring in pediatric patients. Once validated with locally developed normative data, reference intervals provided herein could be used to determine screen fail criteria for serial monitoring using DPOAEs. Employing state-of-the-art calibration techniques might reduce variability, allowing for more sensitive screen fail criteria.


Asunto(s)
Ototoxicidad , Adulto , Teorema de Bayes , Niño , Femenino , Humanos , Masculino , Emisiones Otoacústicas Espontáneas , Valores de Referencia , Reproducibilidad de los Resultados
6.
J Acoust Soc Am ; 147(2): EL201, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-32113282

RESUMEN

Measures of signal-in-noise neural encoding may improve understanding of the hearing-in-noise difficulties experienced by many individuals in everyday life. Usually noise results in weaker envelope following responses (EFRs); however, some studies demonstrate EFR enhancements. This experiment tested whether noise-induced enhancements in EFRs are demonstrated with simple 500- and 1000-Hz pure tones amplitude modulated at 110 Hz. Most of the 12 young normal-hearing participants demonstrated enhanced encoding of the 110-Hz fundamental in a noise background compared to quiet; in contrast, responses at the harmonics were decreased in noise relative to quiet conditions. Possible mechanisms of such an enhancement are discussed.


Asunto(s)
Potenciales Evocados Auditivos , Ruido , Estimulación Acústica , Adulto , Audición , Humanos , Ruido/efectos adversos
7.
Ear Hear ; 40(4): 1035-1038, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30407937

RESUMEN

OBJECTIVES: The objective of this study was to develop a framework for investigating the roles of neural coding and cognition in speech perception. DESIGN: N1 and P3 auditory evoked potentials, QuickSIN speech understanding scores, and the Digit Symbol Coding cognitive test results were used to test the accuracy of either a compensatory processing model or serial processing model. RESULTS: The current dataset demonstrated that neither the compensatory nor the serial processing model were well supported. An additive processing model may best represent the relationships in these data. CONCLUSIONS: With the outcome measures used in this study, it is apparent that an additive processing model, where exogenous neural coding and higher order cognition contribute independently, best describes the effects of neural coding and cognition on speech perception. Further testing with additional outcome measures and a larger number of subjects is needed to confirm and further clarify the relationships between these processing domains.


Asunto(s)
Cognición/fisiología , Potenciales Relacionados con Evento P300/fisiología , Potenciales Evocados Auditivos/fisiología , Percepción del Habla/fisiología , Adulto , Anciano , Comprensión , Femenino , Humanos , Masculino , Persona de Mediana Edad , Relación Señal-Ruido
8.
Ear Hear ; 40(2): 227-242, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-29847413

RESUMEN

OBJECTIVES: This randomized controlled trial evaluated the efficacy of delivering coping skills education from Progressive Tinnitus Management (PTM) by telephone (Tele-PTM). The trial followed a previous pilot study that showed positive results for Tele-PTM. DESIGN: Participants included individuals with bothersome tinnitus (N = 205) located anywhere within the United States. A special emphasis was given to including individuals who had experienced one or more traumatic brain injuries (TBIs). Participants were randomized to either Tele-PTM intervention or 6-month wait-list control (WLC). The Tele-PTM intervention involved five telephone appointments-two led by an audiologist (teaching how to use therapeutic sound) and three by a psychologist (teaching coping skills derived from cognitive-behavioral therapy). It was hypothesized that Tele-PTM would be more effective than WLC in reducing functional effects of tinnitus as measured with the Tinnitus Functional Index. Additional outcome measures included the Self-Efficacy for Managing Reactions to Tinnitus questionnaire and the Hospital Anxiety and Depression Scale. The effect of Tele-PTM on outcomes was estimated using linear mixed models. RESULTS: Overall results showed convincingly that the Tele-PTM group had significantly better outcomes than the WLC group. These results were consistent across all outcome measures, indicating not only a reduction of tinnitus functional distress but also increased self-efficacy. Improvements in measures of anxiety and depression were also observed. Tele-PTM participants in all TBI categories showed significant improvement. CONCLUSIONS: Results provide strong support for use of Tele-PTM methodology for persons with bothersome tinnitus, regardless of whether the person also has TBI symptoms. The effect size for Tele-PTM was high for the primary outcome measure, the Tinnitus Functional Index, and all other outcome measures showed significant improvement. Combined with our previous pilot study, the Tele-PTM method is validated for potential nationwide provision of tinnitus services.


Asunto(s)
Estimulación Acústica/métodos , Adaptación Psicológica , Lesiones Traumáticas del Encéfalo/psicología , Terapia Cognitivo-Conductual/métodos , Educación del Paciente como Asunto , Teléfono , Acúfeno/rehabilitación , Adulto , Anciano , Anciano de 80 o más Años , Ansiedad/psicología , Audiólogos , Lesiones Traumáticas del Encéfalo/complicaciones , Estudios de Casos y Controles , Depresión/psicología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Psicología , Autoeficacia , Telemedicina , Acúfeno/complicaciones , Acúfeno/psicología , Resultado del Tratamiento , Listas de Espera
9.
J Acoust Soc Am ; 146(5): 3849, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31795660

RESUMEN

Tinnitus is one of the predicted perceptual consequences of cochlear synaptopathy, a type of age-, noise-, or drug-induced auditory damage that has been demonstrated in animal models to cause homeostatic changes in central auditory gain. Although synaptopathy has been observed in human temporal bones, assessment of this condition in living humans is limited to indirect non-invasive measures such as the auditory brainstem response (ABR). In animal models, synaptopathy is associated with a reduction in ABR wave I amplitude at suprathreshold stimulus levels. Several human studies have explored the relationship between wave I amplitude and tinnitus, with conflicting results. This study investigates the hypothesis that reduced peripheral auditory input due to synaptic/neuronal loss is associated with tinnitus. Wave I amplitude data from 193 individuals [43 with tinnitus (22%), 150 without tinnitus (78%)], who participated in up to 3 out of 4 different studies, were included in a logistic regression analysis to estimate the relationship between wave I amplitude and tinnitus at a variety of stimulus levels and frequencies. Statistical adjustment for sex and distortion product otoacoustic emissions (DPOAEs) was included. The results suggest that smaller wave I amplitudes and/or lower DPOAE levels are associated with an increased probability of tinnitus.


Asunto(s)
Nervio Coclear/fisiopatología , Potenciales Evocados Auditivos del Tronco Encefálico , Acúfeno/fisiopatología , Adulto , Percepción Auditiva , Autoevaluación Diagnóstica , Femenino , Humanos , Masculino , Persona de Mediana Edad , Ruido , Transmisión Sináptica , Acúfeno/diagnóstico
10.
Ear Hear ; 39(5): 881-894, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29337762

RESUMEN

OBJECTIVES: To determine whether auditory brainstem response (ABR) wave I amplitude is associated with measures of auditory perception in young people with normal distortion product otoacoustic emissions (DPOAEs) and varying levels of noise exposure history. DESIGN: Tinnitus, loudness tolerance, and speech perception ability were measured in 31 young military Veterans and 43 non-Veterans (19 to 35 years of age) with normal pure-tone thresholds and DPOAEs. Speech perception was evaluated in quiet using Northwestern University Auditory Test (NU-6) word lists and in background noise using the words in noise (WIN) test. Loudness discomfort levels were measured using 1-, 3-, 4-, and 6-kHz pulsed pure tones. DPOAEs and ABRs were collected in each participant to assess outer hair cell and auditory nerve function. RESULTS: The probability of reporting tinnitus in this sample increased by a factor of 2.0 per 0.1 µV decrease in ABR wave I amplitude (95% Bayesian confidence interval, 1.1 to 5.0) for males and by a factor of 2.2 (95% confidence interval, 1.0 to 6.4) for females after adjusting for sex and DPOAE levels. Similar results were obtained in an alternate model adjusted for pure-tone thresholds in addition to sex and DPOAE levels. No apparent relationship was found between wave I amplitude and either loudness tolerance or speech perception in quiet or noise. CONCLUSIONS: Reduced ABR wave I amplitude was associated with an increased risk of tinnitus, even after adjusting for DPOAEs and sex. In contrast, wave III and V amplitudes had little effect on tinnitus risk. This suggests that changes in peripheral input at the level of the inner hair cell or auditory nerve may lead to increases in central gain that give rise to the perception of tinnitus. Although the extent of synaptopathy in the study participants cannot be measured directly, these findings are consistent with the prediction that tinnitus may be a perceptual consequence of cochlear synaptopathy.


Asunto(s)
Percepción Auditiva/fisiología , Nervio Coclear/fisiología , Potenciales Evocados Auditivos del Tronco Encefálico/fisiología , Ruido/efectos adversos , Acúfeno/fisiopatología , Adulto , Umbral Auditivo , Femenino , Células Ciliadas Auditivas Internas/fisiología , Humanos , Hiperacusia/fisiopatología , Masculino , Factores Sexuales , Acúfeno/etiología , Veteranos , Adulto Joven
11.
Ear Hear ; 39(1): 69-84, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-28708814

RESUMEN

OBJECTIVES: The goal of this study was to investigate the use of transient-evoked otoacoustic emissions (TEOAEs) and middle ear absorbance measurements to monitor auditory function in patients with cystic fibrosis (CF) receiving ototoxic medications. TEOAEs were elicited with a chirp stimulus using an extended bandwidth (0.71 to 8 kHz) to measure cochlear function at higher frequencies than traditional TEOAEs. Absorbance over a wide bandwidth (0.25 to 8 kHz) provides information on middle ear function. The combination of these time-efficient measurements has the potential to identify early signs of ototoxic hearing loss. DESIGN: A longitudinal study design was used to monitor the hearing of 91 patients with CF (median age = 25 years; age range = 15 to 63 years) who received known ototoxic medications (e.g., tobramycin) to prevent or treat bacterial lung infections. Results were compared to 37 normally hearing young adults (median age = 32.5 years; age range = 18 to 65 years) without a history of CF or similar treatments. Clinical testing included 226-Hz tympanometry, pure-tone air-conduction threshold testing from 0.25 to 16 kHz and bone conduction from 0.25 to 4 kHz. Experimental testing included wideband absorbance at ambient and tympanometric peak pressure and TEOAEs in three stimulus conditions: at ambient pressure and at tympanometric peak pressure using a chirp stimulus with constant incident pressure level across frequency and at ambient pressure using a chirp stimulus with constant absorbed sound power across frequency. RESULTS: At the initial visit, behavioral audiometric results indicated that 76 of the 157 ears (48%) from patients with CF had normal hearing, whereas 81 of these ears (52%) had sensorineural hearing loss for at least one frequency. Seven ears from four patients had a confirmed behavioral change in hearing threshold for ≥3 visits during study participation. Receiver operating characteristic curve analyses demonstrated that all three TEOAE conditions were useful for distinguishing CF ears with normal hearing from ears with sensorineural hearing loss, with an area under the receiver operating characteristic curve values ranging from 0.78 to 0.92 across methods for frequency bands from 2.8 to 8 kHz. Case studies are presented to illustrate the relationship between changes in audiometric thresholds, TEOAEs, and absorbance across study visits. Absorbance measures permitted identification of potential middle ear dysfunction at 5.7 kHz in an ear that exhibited a temporary hearing loss. CONCLUSIONS: The joint use of TEOAEs and absorbance has the potential to explain fluctuations in audiometric thresholds due to changes in cochlear function, middle ear function, or both. These findings are encouraging for the joint use of TEOAE and wideband absorbance objective tests for monitoring ototoxicity, particularly, in patients who may be too ill for behavioral hearing tests. Additional longitudinal studies are needed in a larger number of CF patients receiving ototoxic drugs to further evaluate the clinical utility of these measures in an ototoxic monitoring program.


Asunto(s)
Aminoglicósidos/efectos adversos , Antibacterianos/efectos adversos , Fibrosis Quística/complicaciones , Citotoxinas/efectos adversos , Pérdida Auditiva Sensorineural/diagnóstico , Emisiones Otoacústicas Espontáneas , Adolescente , Adulto , Aminoglicósidos/uso terapéutico , Antibacterianos/uso terapéutico , Audiometría , Umbral Auditivo , Fibrosis Quística/tratamiento farmacológico , Oído Medio/fisiopatología , Femenino , Pérdida Auditiva Sensorineural/inducido químicamente , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Adulto Joven
12.
Int J Audiol ; 57(2): 143-149, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29022411

RESUMEN

OBJECTIVE: This study obtained preliminary data using two types of sound therapy to suppress tinnitus and/or reduce its functional effects: (1) Notched noise (1000-12,000 Hz notched within a 1-octave range centred around the tinnitus pitch match [PM] frequency); and (2) Matched noise (1-octave wide band of noise centred around the PM frequency). A third (Placebo) group listened to low frequency noise (250-700 Hz). DESIGN: Participants with bothersome tinnitus were randomised into one of the three groups and instructed to listen to the acoustic stimulus for 6 hours a day for 2 weeks. Stimuli were delivered using an iPod Nano, and tinnitus counselling was not performed. Outcome measures were recorded at the 0, 2 and 4 week study visits. STUDY SAMPLE: Thirty participants with constant and bothersome tinnitus were recruited and randomised. RESULTS: All groups showed, on average, overall improvement, both immediately post-treatment and 2 weeks following treatment. Outcomes varied between groups on the different measures and at the two outcome points. CONCLUSION: This study showed improvement for all of the groups, lending support to the premise that any type of sound stimulation is beneficial for relieving effects of tinnitus. These results may serve as a preliminary evidence for a larger study.


Asunto(s)
Estimulación Acústica/métodos , Acúfeno/terapia , Adulto , Anciano , Percepción Auditiva , Femenino , Humanos , Reproductor MP3 , Masculino , Persona de Mediana Edad , Ruido , Sonido , Acúfeno/fisiopatología , Resultado del Tratamiento
13.
Biometrics ; 73(1): 334-343, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-27332505

RESUMEN

Distortion product otoacoustic emissions (DPOAE) testing is a promising alternative to behavioral hearing tests and auditory brainstem response testing of pediatric cancer patients. The central goal of this study is to assess whether significant changes in the DPOAE frequency/emissions curve (DP-gram) occur in pediatric patients in a test-retest scenario. This is accomplished through the construction of normal reference charts, or credible regions, that DP-gram differences lie in, as well as contour probabilities that measure how abnormal (or in a certain sense rare) a test-retest difference is. A challenge is that the data were collected over varying frequencies, at different time points from baseline, and on possibly one or both ears. A hierarchical structural equation Gaussian process model is proposed to handle the different sources of correlation in the emissions measurements, wherein both subject-specific random effects and variance components governing the smoothness and variability of each child's Gaussian process are coupled together.


Asunto(s)
Técnicas de Diagnóstico Otológico/estadística & datos numéricos , Pruebas Auditivas/estadística & datos numéricos , Distribución Normal , Análisis de Varianza , Niño , Preescolar , Femenino , Humanos , Lactante , Masculino , Valores de Referencia , Factores de Tiempo
14.
Ear Hear ; 38(1): e1-e12, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-27992391

RESUMEN

OBJECTIVES: Recent animal studies demonstrated that cochlear synaptopathy, a partial loss of inner hair cell-auditory nerve fiber synapses, can occur in response to noise exposure without any permanent auditory threshold shift. In animal models, this synaptopathy is associated with a reduction in the amplitude of wave I of the auditory brainstem response (ABR). The goal of this study was to determine whether higher lifetime noise exposure histories in young people with clinically normal pure-tone thresholds are associated with lower ABR wave I amplitudes. DESIGN: Twenty-nine young military Veterans and 35 non Veterans (19 to 35 years of age) with normal pure-tone thresholds were assigned to 1 of 4 groups based on their self-reported lifetime noise exposure history and Veteran status. Suprathreshold ABR measurements in response to alternating polarity tone bursts were obtained at 1, 3, 4, and 6 kHz with gold foil tiptrode electrodes placed in the ear canal. Wave I amplitude was calculated from the difference in voltage at the positive peak and the voltage at the following negative trough. Distortion product otoacoustic emission input/output functions were collected in each participant at the same four frequencies to assess outer hair cell function. RESULTS: After controlling for individual differences in sex and distortion product otoacoustic emission amplitude, the groups containing participants with higher reported histories of noise exposure had smaller ABR wave I amplitudes at suprathreshold levels across all four frequencies compared with the groups with less history of noise exposure. CONCLUSIONS: Suprathreshold ABR wave I amplitudes were reduced in Veterans reporting high levels of military noise exposure and in non Veterans reporting any history of firearm use as compared with Veterans and non Veterans with lower levels of reported noise exposure history. The reduction in ABR wave I amplitude in the groups with higher levels of noise exposure cannot be accounted for by sex or variability in outer hair cell function. This change is similar to the decreased ABR wave I amplitudes observed in animal models of noise-induced cochlear synaptopathy. However, without post mortem examination of the temporal bone, no direct conclusions can be drawn concerning the presence of synaptopathy in the study groups with higher noise exposure histories.


Asunto(s)
Potenciales Evocados Auditivos del Tronco Encefálico/fisiología , Células Ciliadas Auditivas Externas/fisiología , Pérdida Auditiva Provocada por Ruido/fisiopatología , Enfermedades del Nervio Vestibulococlear/fisiopatología , Veteranos , Adulto , Audiometría de Tonos Puros , Umbral Auditivo , Estudios de Casos y Controles , Femenino , Humanos , Masculino , Ruido , Emisiones Otoacústicas Espontáneas , Adulto Joven
15.
Ear Hear ; 38(4): 507-520, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28437273

RESUMEN

OBJECTIVES: An important clinical application of transient-evoked otoacoustic emissions (TEOAEs) is to evaluate cochlear outer hair cell function for the purpose of detecting sensorineural hearing loss (SNHL). Double-evoked TEOAEs were measured using a chirp stimulus, in which the stimuli had an extended frequency range compared to clinical tests. The present study compared TEOAEs recorded using an unweighted stimulus presented at either ambient pressure or tympanometric peak pressure (TPP) in the ear canal and TEOAEs recorded using a power-weighted stimulus at ambient pressure. The unweighted stimulus had approximately constant incident pressure magnitude across frequency, and the power-weighted stimulus had approximately constant absorbed sound power across frequency. The objective of this study was to compare TEOAEs from 0.79 to 8 kHz using these three stimulus conditions in adults to assess test performance in classifying ears as having either normal hearing or SNHL. DESIGN: Measurements were completed on 87 adult participants. Eligible participants had either normal hearing (N = 40; M F = 16 24; mean age = 30 years) or SNHL (N = 47; M F = 20 27; mean age = 58 years), and normal middle ear function as defined by standard clinical criteria for 226-Hz tympanometry. Clinical audiometry, immittance, and an experimental wideband test battery, which included reflectance and TEOAE tests presented for 1-min durations, were completed for each ear on all participants. All tests were then repeated 1 to 2 months later. TEOAEs were measured by presenting the stimulus in the three stimulus conditions. TEOAE data were analyzed in each hearing group in terms of the half-octave-averaged signal to noise ratio (SNR) and the coherence synchrony measure (CSM) at frequencies between 1 and 8 kHz. The test-retest reliability of these measures was calculated. The area under the receiver operating characteristic curve (AUC) was measured at audiometric frequencies between 1 and 8 kHz to determine TEOAE test performance in distinguishing SNHL from normal hearing. RESULTS: Mean TEOAE SNR was ≥8.7 dB for normal-hearing ears and ≤6 dB for SNHL ears for all three stimulus conditions across all frequencies. Mean test-retest reliability of TEOAE SNR was ≤4.3 dB for both hearing groups across all frequencies, although it was generally less (≤3.5 dB) for lower frequencies (1 to 4 kHz). AUCs were between 0.85 and 0.94 for all three TEOAE conditions at all frequencies, except for the ambient TEOAE condition at 2 kHz (0.82) and for all TEOAE conditions at 5.7 kHz with AUCs between 0.78 and 0.81. Power-weighted TEOAE AUCs were significantly higher (p < 0.05) than ambient TEOAE AUCs at 2 and 2.8 kHz, as was the TPP TEOAE AUC at 2.8 kHz when using CSM as the classifier variable. CONCLUSIONS: TEOAEs evaluated in an ambient condition, at TPP and in a power-weighted stimulus condition, had good test performance in identifying ears with SNHL based on SNR and CSM in the frequency range from 1 to 8 kHz and showed good test-retest reliability. Power-weighted TEOAEs showed the best test performance at 2 and 2.8 kHz. These findings are encouraging as a potential objective clinical tool to identify patients with cochlear hearing loss.


Asunto(s)
Células Ciliadas Auditivas Externas , Pérdida Auditiva Sensorineural/fisiopatología , Emisiones Otoacústicas Espontáneas , Estimulación Acústica/métodos , Adulto , Área Bajo la Curva , Estudios de Casos y Controles , Femenino , Pérdida Auditiva Sensorineural/diagnóstico , Humanos , Masculino , Persona de Mediana Edad , Curva ROC , Reproducibilidad de los Resultados , Relación Señal-Ruido
16.
Ear Hear ; 38(3): e142-e160, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28045835

RESUMEN

OBJECTIVES: Wideband acoustic immittance (WAI) measures such as pressure reflectance, parameterized by absorbance and group delay, equivalent admittance at the tympanic membrane (TM), and acoustic stapedius reflex threshold (ASRT) describe middle ear function across a wide frequency range, compared with traditional tests employing a single frequency. The objective of this study was to obtain normative data using these tests for a group of normal-hearing adults and investigate test-retest reliability using a longitudinal design. DESIGN: A longitudinal prospective design was used to obtain normative test and retest data on clinical and WAI measures. Subjects were 13 males and 20 females (mean age = 26 years). Inclusion criteria included normal audiometry and clinical immittance. Subjects were tested on two separate visits approximately 1 month apart. Reflectance and equivalent admittance at the TM were measured from 0.25 to 8.0 kHz under three conditions: at ambient pressure in the ear canal and with pressure sweeps from positive to negative pressure (downswept) and negative to positive pressure (upswept). Equivalent admittance at the TM was calculated using admittance measurements at the probe tip that were adjusted using a model of sound transmission in the ear canal and acoustic estimates of ear-canal area and length. Wideband ASRTs were measured at tympanometric peak pressure (TPP) derived from the average TPP of downswept and upswept tympanograms. Descriptive statistics were obtained for all WAI responses, and wideband and clinical ASRTs were compared. RESULTS: Mean absorbance at ambient pressure and TPP demonstrated a broad band-pass pattern typical of previous studies. Test-retest differences were lower for absorbance at TPP for the downswept method compared with ambient pressure at frequencies between 1.0 and 1.26 kHz. Mean tympanometric peak-to-tail differences for absorbance were greatest around 1.0 to 2.0 kHz and similar for positive and negative tails. Mean group delay at ambient pressure and at TPP were greatest between 0.32 and 0.6 kHz at 200 to 300 µsec, reduced at frequencies between 0.8 and 1.5 kHz, and increased above 1.5 kHz to around 150 µsec. Mean equivalent admittance at the TM had a lower level for the ambient method than at TPP for both sweep directions below 1.2 kHz, but the difference between methods was only statistically significant for the comparison between the ambient method and TPP for the upswept tympanogram. Mean equivalent admittance phase was positive at all frequencies. Test-retest reliability of the equivalent admittance level ranged from 1 to 3 dB at frequencies below 1.0 kHz, but increased to 8 to 9 dB at higher frequencies. The mean wideband ASRT for an ipsilateral broadband noise activator was 12 dB lower than the clinical ASRT, but had poorer reliability. CONCLUSIONS: Normative data for the WAI test battery revealed minor differences for results at ambient pressure compared with tympanometric methods at TPP for reflectance, group delay, and equivalent admittance level at the TM for subjects with middle ear pressure within ±100 daPa. Test-retest reliability was better for absorbance at TPP for the downswept tympanogram compared with ambient pressure at frequencies around 1.0 kHz. Large peak-to-tail differences in absorbance combined with good reliability at frequencies between about 0.7 and 3.0 kHz suggest that this may be a sensitive frequency range for interpreting absorbance at TPP. The mean wideband ipsilateral ASRT was lower than the clinical ASRT, consistent with previous studies. Results are promising for the use of a wideband test battery to evaluate middle ear function.


Asunto(s)
Cóclea/fisiología , Oído Medio/fisiología , Estapedio/fisiología , Membrana Timpánica/fisiología , Pruebas de Impedancia Acústica , Acústica , Adulto , Audiometría , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Valores de Referencia , Reflejo/fisiología , Reproducibilidad de los Resultados , Adulto Joven
17.
Ear Hear ; 37(3): e173-87, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26656318

RESUMEN

OBJECTIVES: (1) To characterize the influence of type 2 diabetes mellitus (DM) on cortical auditory-evoked potentials (CAEPs) separate from the effects of normal aging, and (2) to determine whether the disease-related effects are modified by insulin dependence. DESIGN: A cross-sectional study was conducted in a large cohort of Veterans to investigate the relationships among type 2 DM, age, and CAEPs in randomly selected participants with (N = 108) and without (N = 114) the disease and who had no more than a moderate hearing loss. Participants with DM were classified as insulin-dependent (IDDM, N = 47) or noninsulin-dependent (NIDDM, N = 61). Other DM measures included concurrent serum glucose, HbA1c, and duration of disease. CAEPs were evoked using a passive homogeneous paradigm (single repeating stimulus) by suprathreshold tones presented to the right ear, left ear, or both ears. Outcome measures were adjusted for the pure-tone threshold average for frequencies of 0.5, 1, and 2 kHz and analyzed for differences in age effects between participant groups using multiple regression. RESULTS: There is little variation across test ear conditions (left, right, binaural) on any CAEP peak in any of the groups. Among no-DM controls, P2 latency increases about 9 msec per decade of life. DM is associated with an additional delay in the P2 latency of 7 and 9 msec for the IDDM and NIDDM groups, respectively. Moreover, the slope of the function relating P2 latency with age is similar across participant groups and thus the DM effect appears constant across age. Effects on N1 latency are considerably weaker, with age effects of less than 4 msec per decade across all groups, and DM effects of only 2 (IDDM) or 3 msec (NIDDM). In the NIDDM group, the slope relating N1 latency to age is steeper relative to that observed for the no-DM group, providing some evidence of accelerated "aging" for this CAEP peak. DM does not substantially reduce N1-P2 amplitude and age relationships with N1-P2 amplitude are effectively absent. There is no association between pure-tone average at 0.5, 1, and 2 kHz and any aspect of CAEPs in this cohort. CONCLUSIONS: In a large cohort of Veterans, we found that type 2 DM is associated with prolonged N1 and P2 latencies regardless of whether insulin is required to manage the disease and independent of peripheral hearing thresholds. The DM-related effects on CAEP latencies are threefold greater for P2 compared with N1, and there is little support that at the cortical level, IDDM participants had poorer responses compared with NIDDM participants, although their responses were more variable. Overall, these results indicate that DM is associated with slowed preattentive neural conduction. Moreover, the observed 7 to 9 msec P2 latency delay due to DM is substantial compared with normal age changes in P2, which are 9 msec per decade of life in this cohort. Results also suggest that whereas N1 latency changes with age are more pronounced among individuals with DM versus without DM, there was no evidence for more rapid aging of P2 among patients with DM. Thus, the damage responsible for the major DM-related differences may occur early in the DM disease process. These cross-sectional results should be verified using a longitudinal study design.


Asunto(s)
Envejecimiento/fisiología , Diabetes Mellitus Tipo 2/fisiopatología , Potenciales Evocados Auditivos/fisiología , Anciano , Glucemia/metabolismo , Estudios de Casos y Controles , Estudios de Cohortes , Estudios Transversales , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Diabetes Mellitus Tipo 2/metabolismo , Electroencefalografía , Femenino , Hemoglobina Glucada/metabolismo , Humanos , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Masculino , Persona de Mediana Edad , Índice de Severidad de la Enfermedad , Factores de Tiempo , Veteranos
18.
Ear Hear ; 36(6): 710-22, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26502191

RESUMEN

OBJECTIVES: Speech perception in background noise is difficult for many individuals, and there is considerable performance variability across listeners. The combination of physiological and behavioral measures may help to understand sources of this variability for individuals and groups and prove useful clinically with hard-to-test populations. The purpose of this study was threefold: (1) determine the effect of signal-to-noise ratio (SNR) and signal level on cortical auditory evoked potentials (CAEPs) and sentence-level perception in older normal-hearing (ONH) and older hearing-impaired (OHI) individuals, (2) determine the effects of hearing impairment and age on CAEPs and perception, and (3) explore how well CAEPs correlate with and predict speech perception in noise. DESIGN: Two groups of older participants (15 ONH and 15 OHI) were tested using speech-in-noise stimuli to measure CAEPs and sentence-level perception of speech. The syllable /ba/, used to evoke CAEPs, and sentences were presented in speech-spectrum background noise at four signal levels (50, 60, 70, and 80 dB SPL) and up to seven SNRs (-10, -5, 0, 5, 15, 25, and 35 dB). These data were compared between groups to reveal the hearing impairment effect and then combined with previously published data for 15 young normal-hearing individuals to determine the aging effect. RESULTS: Robust effects of SNR were found for perception and CAEPs. Small but significant effects of signal level were found for perception, primarily at poor SNRs and high signal levels, and in some limited instances for CAEPs. Significant effects of age were seen for both CAEPs and perception, while hearing impairment effects were only found with perception measures. CAEPs correlate well with perception and can predict SNR50s to within 2 dB for ONH. However, prediction error is much larger for OHI and varies widely (from 6 to 12 dB) depending on the model that was used for prediction. CONCLUSIONS: When background noise is present, SNR dominates both perception-in-noise testing and cortical electrophysiological testing, with smaller and sometimes significant contributions from signal level. A mismatch between behavioral and electrophysiological results was found (hearing impairment effects were primarily only seen for behavioral data), illustrating the possible contributions of higher order cognitive processes on behavior. It is interesting that the hearing impairment effect size was more than five times larger than the aging effect size for CAEPs and perception. Sentence-level perception can be predicted well in normal-hearing individuals; however, additional research is needed to explore improved prediction methods for older individuals with hearing impairment.


Asunto(s)
Corteza Auditiva/fisiopatología , Potenciales Evocados Auditivos/fisiología , Pérdida Auditiva Sensorineural/fisiopatología , Ruido , Percepción del Habla/fisiología , Factores de Edad , Anciano , Anciano de 80 o más Años , Audiometría de Tonos Puros , Electroencefalografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Relación Señal-Ruido
19.
Ear Hear ; 36(5): e251-60, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25985018

RESUMEN

OBJECTIVE: Distortion product otoacoustic emissions (DPOAEs) have long been heralded as a means to objectively monitor cochlear function and increasingly are becoming a key component in hearing surveillance programs for individuals at risk for ototoxic- and occupational noise-related hearing loss. Yet clinicians are unsure how to define clinically meaningful shifts in DPOAE level. In this study, a meta-analysis approach is used to synthesize the DPOAE level test-retest literature to construct a set of DPOAE level shift reference limits that can be used clinically to define a statistically significant emission change. DESIGN: The authors reviewed all published articles identified through a Medline search using the terms "Otoacoustic Emission Variability," "Otoacoustic Emission Reliability," "Otoacoustic Emission Repeatability," and "Otoacoustic Emission Test Retest" restricted to DPOAEs, adults, and English language. Articles with DPOAE level data elicited by moderate stimulus levels for f2 frequencies of 1000, 2000, 4000, or 6000 Hz were selected because these stimulus parameters were relatively well represented in the literature. The authors only included articles that reported the standard error of the measurement (SEM) or from which the SEM could be calculated. Meta-analysis was used to estimate the population mean SEM over the included studies. Models were fit separately for each f2 primary and included days since baseline and study-specific random effects. RESULTS: Ten DPOAE test-retest studies met inclusion criteria for this meta-analysis. The SEM values varied widely across published studies (0.57 to 3.9 dB) and were provided for relatively short time intervals (less than 15 days on average). Time, or days since baseline, was statistically significant at higher f2 frequencies (4000 and 6000 Hz). From the model results, 90% reference limits specific to the f2 and elapsed time between baseline and follow-up measurements were established. Reference limits provided correspond to negative (emission decrement) and positive (emission enhancement) shifts indicative of the amount of measurement variability that, using this approach, must be tolerated as "normal" fluctuations over time. Changes larger than the reference limits are considered significant and warrant follow-up testing. CONCLUSIONS: The meta-analysis presented provides reference limits that are appropriate for a set of specific f2 frequencies and time intervals. The meta-analysis concerns the SEM statistic directly, so that any preferred reference limit can be computed from the results and should be predicated upon the screening application. The presumed advantage of this meta-analytic approach is increased precision relative to limits suggested by any of the individual studies included in the analysis.


Asunto(s)
Cóclea/fisiopatología , Pérdida Auditiva Sensorineural/diagnóstico , Emisiones Otoacústicas Espontáneas , Adulto , Humanos , Reproducibilidad de los Resultados
20.
Hum Factors ; 57(8): 1443-58, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26224085

RESUMEN

OBJECTIVE: This study assessed listeners' ability to localize spatially differentiated virtual audio signals delivered by bone conduction (BC) vibrators and circumaural air conduction (AC) headphones. BACKGROUND: Although the skull offers little intracranial sound wave attenuation, previous studies have demonstrated listeners' ability to localize auditory signals delivered by a pair of BC vibrators coupled to the mandibular condyle bones. The current study extended this research to other BC vibrator locations on the skull. METHOD: Each participant listened to virtual audio signals originating from 16 different horizontal locations using circumaural headphones or BC vibrators placed in front of, above, or behind the listener's ears. The listener's task was to indicate the signal's perceived direction of origin. RESULTS: Localization accuracy with the BC front and BC top positions was comparable to that with the headphones, but responses for the BC back position were less accurate than both the headphones and BC front position. CONCLUSION: This study supports the conclusion of previous studies that listeners can localize virtual 3D signals equally well using AC and BC transducers. Based on these results, it is apparent that BC devices could be substituted for AC headphones with little to no localization performance degradation. APPLICATION: BC headphones can be used when spatial auditory information needs to be delivered without occluding the ears. Although vibrator placement in front of the ears appears optimal from the localization standpoint, the top or back position may be acceptable from an operational standpoint or if the BC system is integrated into headgear.


Asunto(s)
Conducción Ósea/fisiología , Localización de Sonidos/fisiología , Percepción Espacial/fisiología , Vibración , Adolescente , Adulto , Femenino , Humanos , Masculino , Cráneo/fisiología , Análisis y Desempeño de Tareas , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA