Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
J Med Internet Res ; 22(11): e19180, 2020 11 12.
Artículo en Inglés | MEDLINE | ID: mdl-33180025

RESUMEN

BACKGROUND: Patients with malignant pleural mesothelioma (MPM) have a life-limiting illness and short prognosis and experience many debilitating symptoms from early in the illness. Innovations such as remote symptom monitoring are needed to enable patients to maintain wellbeing and manage symptoms in a proactive and timely manner. The Advanced Symptom Management System (ASyMS) has been successfully used to monitor symptoms associated with cancer. OBJECTIVE: This study aimed to determine the feasibility and acceptability of using an ASyMS adapted for use by patients with MPM, called ASyMSmeso, enabling the remote monitoring of symptoms using a smartphone. METHODS: This was a convergent mixed methods study using patient-reported outcome measures (PROMs) at key time points over a period of 2-3 months with 18 patients. The Sheffield Profile for Assessment and Referral for Care (SPARC), Technology Acceptance Model (TAM) measure for eHealth, and Lung Cancer Symptom Scale-Mesothelioma (LCSS-Meso) were the PROMs used in the study. Patients were also asked to complete a daily symptom questionnaire on a smartphone throughout the study. At the end of the study, semistructured interviews with 11 health professionals, 8 patients, and 3 carers were conducted to collect their experience with using ASyMSmeso. RESULTS: Eighteen patients with MPM agreed to participate in the study (33.3% response rate). The completion rates of study PROMs were high (97.2%-100%), and completion rates of the daily symptom questionnaire were also high, at 88.5%. There were no significant changes in quality of life, as measured by LCSS-Meso. There were statistically significant improvements in the SPARC psychological need domain (P=.049) and in the "Usefulness" domain of the TAM (P=.022). End-of-study interviews identified that both patients and clinicians found the system quick and easy to use. For patients, in particular, the system provided reassurance about symptom experience and the feeling of being listened to. The clinicians largely viewed the system as feasible and acceptable, and areas that were mentioned included the early management of symptoms and connectivity between patients and clinicians, leading to enhanced communication. CONCLUSIONS: This study demonstrates that remote monitoring and management of symptoms of people with MPM using a mobile phone are feasible and acceptable. The evidence supports future trials using remote symptom monitoring to support patients with MPM at home.


Asunto(s)
Mesotelioma Maligno/terapia , Calidad de Vida/psicología , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Mesotelioma Maligno/mortalidad , Mesotelioma Maligno/patología , Persona de Mediana Edad , Pronóstico , Análisis de Supervivencia
2.
BMJ Open Respir Res ; 7(1)2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-33148778

RESUMEN

INTRODUCTION: The COVID-19 pandemic has been characterised by significant in-hospital virus transmission and deaths among healthcare workers. Sources of in-hospital transmission are not fully understood, with special precautions currently reserved for procedures previously shown to generate aerosols (particles <5 µm). Pleural procedures are not currently considered AGPs (Aerosol Generating Procedures), reflecting a lack of data in this area. METHODS: An underwater seal chest drain bottle (R54500, Rocket Medical UK) was set up inside a 60-litre plastic box and connected via an airtight conduit to a medical air supply. A multichannel particle counter (TSI Aerotrak 9310 Aerosol Monitor) was placed inside the box, allowing measurement of particle count/cubic foot (pc/ft3) within six channel sizes: 0.3-0.5, 0.5-1, 1-3, 3-5, 5-10 and >10 µm. Stabilised particle counts at 1, 3 and 5 L/min were compared by Wilcoxon signed rank test; p values were Bonferroni-adjusted. Measurements were repeated with a simple anti-viral filter, designed using repurposed materials by the study team, attached to the drain bottle. The pressure within the bottle was measured to assess any effect of the filter on bottle function. RESULTS: Aerosol emissions increased with increasing air flow, with the largest increase observed in smaller particles (0.3-3 µm). Concentration of the smallest particles (0.3-0.5 µm) increased from background levels by 700, 1400 and 2500 pc/ft3 at 1, 3 and 5 L/min, respectively. However, dispersion of particles of all sizes was effectively prevented by use of the viral filter at all flow rates. Use of the filter was associated with a maximum pressure rise of 0.3 cm H2O after 24 hours of flow at 5 L/min, suggesting minimal impact on drain function. CONCLUSION: A bubbling chest drain is a source of aerosolised particles, but emission can be prevented using a simple anti-viral filter. These data should be considered when designing measures to reduce in-hospital spread of SARS-CoV-2.


Asunto(s)
Betacoronavirus , Tubos Torácicos , Infecciones por Coronavirus/transmisión , Personal de Salud , Transmisión de Enfermedad Infecciosa de Paciente a Profesional/prevención & control , Exposición Profesional/prevención & control , Neumonía Viral/transmisión , Aerosoles , COVID-19 , Drenaje , Filtración/instrumentación , Humanos , Pandemias , Tamaño de la Partícula , Material Particulado , SARS-CoV-2
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA