1.
IEEE Trans Biomed Eng ; 66(6): 1542-1548, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-30307855

RESUMEN

The eGaIn coil on neoprene demonstrated in this paper presents a stretchable radio frequency receive coil for magnetic resonance imaging (MRI). The coil with dimensions [Formula: see text] is tuned to resonate at 128 MHz for 3 T MRI. We investigate the effect of stretching (up to 40% strain) and bending (50 mm radius of curvature) of the coil on the coil's resistance and resonance frequency. Measurements and simulations show a decrease in resonance frequency of 2.5 MHz per 10% strain. The higher resistivity of liquid metal compared to copper reduces the SNR of MRI scans by 34%; therefore, a tradeoff between flexibility and performance remains. Nevertheless, we have successfully performed MRI scans with the liquid metal coil.


Asunto(s)
Imagen por Resonancia Magnética/instrumentación , Metales Pesados/química , Simulación por Computador , Diseño de Equipo , Neopreno/química , Fantasmas de Imagen , Docilidad , Relación Señal-Ruido
2.
Front Neurosci ; 13: 819, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31551666

RESUMEN

Optogenetics provide a potential alternative approach to the treatment of chronic pain, in which complex pathology often hampers efficacy of standard pharmacological approaches. Technological advancements in the development of thin, wireless, and mechanically flexible optoelectronic implants offer new routes to control the activity of subsets of neurons and nerve fibers in vivo. This study reports a novel and advanced design of battery-free, flexible, and lightweight devices equipped with one or two miniaturized LEDs, which can be individually controlled in real time. Two proof-of-concept experiments in mice demonstrate the feasibility of these devices. First, we show that blue-light devices implanted on top of the lumbar spinal cord can excite channelrhodopsin expressing nociceptors to induce place aversion. Second, we show that nocifensive withdrawal responses can be suppressed by green-light optogenetic (Archaerhodopsin-mediated) inhibition of action potential propagation along the sciatic nerve. One salient feature of these devices is that they can be operated via modern tablets and smartphones without bulky and complex lab instrumentation. In addition to the optical stimulation, the design enables the simultaneously wireless recording of the temperature in proximity of the stimulation area. As such, these devices are primed for translation to human patients with implications in the treatment of neurological and psychiatric conditions far beyond chronic pain syndromes.

3.
IEEE Trans Med Imaging ; 38(6): 1420-1426, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-30582533

RESUMEN

Stretchable magnetic resonance (MR) receive coils show shifts in their resonance frequency when stretched. An in-field receiver measures the frequency response of a stretchable coil. The receiver and coil are designed to operate at 128 MHz for a 3T MR scanner. Based on the measured frequency response, we are able to detect the changes of the resonance frequency of the coil. We show a proportional-integral-derivative controller that tracks the changes in resonance frequency and retunes the stretchable coil. The settling time of the control loop is less than 3.8ms. The retuning system reduces the loss in signal-to-noise ratio of phantom images from 1.6 dB to 0.3 dB, when the coil is stretched by 40% and the coil is retuned to 128 MHz.


Asunto(s)
Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/métodos , Metales/química , Diseño de Equipo , Femenino , Humanos , Masculino , Neopreno , Fantasmas de Imagen , Relación Señal-Ruido
4.
Adv Mater ; 29(44)2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29027724

RESUMEN

Stretchable conductors based on eutectic gallium-indium (eGaIn) alloy are patterned on a polychloroprene substrate (neoprene foam) using stencil printing. By tuning the amount of eGaIn on the neoprene substrate, different strain-sensitivity of electrical resistance is achieved. Conductors with a layer of eGaIn, which adsorbs to the walls of 60-100 µm wide neoprene cells, change their electrical resistance for 5% at 100% strain. When the amount of eGaIn is increased, the cells are filled with eGaIn and the strain-sensitivity of the electrical resistance rises to 300% at 100% strain. The developed conductors are patterned as stretchable on-body coils for receiving magnetic signals in a clinical magnetic resonance imaging setup. First images with a stretchable coil are acquired on an orange and compared to the images that are recorded using a rigid copper coil of the same size.