RESUMEN
Virus filters are membrane-based devices that remove large viruses (e.g., retroviruses) and/or small viruses (e.g., parvoviruses) from products by a size exclusion mechanism. In 2002, the Parenteral Drug Association (PDA) organized the PDA Virus Filter Task Force to develop a common nomenclature and a standardized test method for classifying and identifying viral-retentive filters. A test method based on bacteriophage PP7 retention was chosen based on developmental studies. The detailed final consensus filter method is published in the 2008 update of PDA Technical Report 41: Virus Filtration. Here, we evaluate the method and find it to be acceptable for testing scaled-down models of small virus-retentive filters from four manufacturers. Three consecutive lots of five filter types were tested (Pegasus SV4, Viresolve NFP, Planova 20N and 15N, Virosart CPV). Each passed the criteria specified in the test method (i.e., >4 log10 PP7 retention, >90% intravenous immunoglobulin passage, and passing integrity/installation testing) and was classified as PP7-LRV4.
Asunto(s)
Levivirus/aislamiento & purificación , Membranas Artificiales , Filtros Microporos , Esterilización/instrumentación , Diseño de Equipo , Guías como Asunto , Inmunoglobulinas Intravenosas/análisis , Ensayo de Materiales , Filtros Microporos/normas , Evaluación de Programas y Proyectos de Salud , Reproducibilidad de los Resultados , Esterilización/normasRESUMEN
Virus filters are membrane-based devices that remove large viruses (e.g., retroviruses) and/or small viruses (e.g., parvoviruses) from products by a size exclusion mechanism. In 2002, the Parenteral Drug Association (PDA) organized the PDA Virus Filter Task Force to develop a common nomenclature and a standardized test method for classifying and identifying viral-retentive filters. One goal of the task force was to develop a test method for small virus-retentive filters. Because small virus-retentive filters present unique technical challenges, the test method development process was guided by laboratory studies to determine critical variables such as choice of bacteriophage challenge, choice of model protein, filtration operating parameters, target log10 reduction value, and filtration endpoint definition. Based on filtration, DLS, electrospray differential mobility analysis, and polymerase chain reaction studies, a final rating based on retention of bacteriophage PP7 was chosen by the PDA Virus Filter Task Force. The detailed final consensus filter method was published in the 2008 update of PDA Technical Report 41. Virus Filtration.