Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Eur Radiol ; 2024 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-39028375

RESUMEN

OBJECTIVES: Magnetic resonance enterography (MRE) interpretation of Crohn's disease (CD) is subjective and uses 2D analysis. We evaluated the feasibility of volumetric measurement of terminal ileal CD on MRE compared to endoscopy and sMARIA, and the responsiveness of volumetric changes to biologics. METHODS: CD patients with MRE and contemporaneous CD endoscopic index of severity-scored ileocolonoscopy were included. A centreline was placed through the terminal ileum (TI) lumen defining the diseased bowel length on the T2-weighted non-fat saturated sequence, used by two radiologists to independently segment the bowel wall to measure volume (phase 1). In phase 2, we measured disease volume in patients treated with biologics, who had undergone pre- and post-treatment MRE, with treatment response classified via global physician assessment. RESULTS: Phase 1 comprised 30 patients (median age 29 (IQR 24, 34) years). Phase 2 included 12 patients (25 years (22, 38)). In phase 1, the mean of the radiologist-measured volumes was used for analysis. The median disease volume in those with endoscopically active CD was 20.9 cm3 (IQR 11.3, 44.0) compared to 5.7 cm3 (2.9, 9.8) with normal endoscopy. The mean difference in disease volume between the radiologists was 3.0 cm3 (limits of agreement -21.8, 15.9). The median disease volume of patients with active CD by sMARIA was 15.0 cm3 (8.7, 44.0) compared to 2.85 cm3 (2.6, 3.1) for those with inactive CD. Pre- and post-treatment median disease volumes were 28.5 cm3 (26.4, 31.2), 11 cm3 (4.8, 16.6), respectively in biological responders, vs 26.8 cm3 (12.3, 48.7), 40.1 cm3 (10, 56.7) in non-responders. CONCLUSION: Volumetric measurement of terminal ileal CD by MRE is feasible, related to endoscopy and sMARIA activity, and responsive to biologics. CLINICAL RELEVANCE STATEMENT: Measuring the whole volume of diseased bowel on MRE in CD is feasible, related to how biologically active the disease is when assessed by endoscopy and by existing MRE activity scores, and is sensitive to treatment response. KEY POINTS: MRE reporting for CD is subjective and uses 2D images rather than assessing the full disease volume. Volumetric measurement of CD relates to endoscopic activity and shows reduced disease volumes in treatment responders. This technique is an objective biomarker that can assess disease activity and treatment response, warranting validation.

2.
J Magn Reson Imaging ; 53(5): 1422-1431, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33331088

RESUMEN

BACKGROUND: Increased small bowel permeability leads to bacterial translocation, associated with significant morbidity and mortality. Biomarkers are needed to evaluate these changes in vivo, stratify an individual's risk, and evaluate the efficacy of interventions. MRI is an established biomarker of small bowel inflammation. PURPOSE: To characterize changes in the small bowel with quantitative MRI measures associated with increased permeability induced by indomethacin. STUDY TYPE: Prospective single-center, double-blind, two-way crossover provocation study. SUBJECTS: A provocation cohort (22 healthy volunteers) and intrasubject reproducibility cohort (8 healthy volunteers). FIELD STRENGTH/SEQUENCE: 2D balanced turbo field echo sequences to measure small bowel wall thickness, T2 , and motility acquired at 3T. ASSESSMENT: Participants were randomized to receive indomethacin or placebo prior to assessment. After a minimum 2-week washout, measures were repeated with the alternative allocation. MR measures (wall thickness, T2 , motility) at each study visit were compared to the reference standard 2-hour lactulose/mannitol urinary excretion ratio (LMR) test performed by a lab technician. All analyses were performed blind. STATISTICAL TESTS: Normality was tested (Shapiro-Wilk's test). Paired testing (Student's t-test or Wilcoxon) determined the significance of paired differences with indomethacin provocation. Pearson's correlation coefficient compared significant measures with indomethacin provocation to LMR. Intrasubject (intraclass correlation) and interrater variability (Bland-Altman) were assessed. RESULTS: Indomethacin provocation induced a significant increase in LMR compared to placebo (P < 0.05) and a significant increase in small bowel T2 (0.12 seconds compared to placebo 0.07 seconds, P < 0.05). Small bowel wall thickness (P = 0.17) and motility (P = 0.149) showed no significant change. T2 and LMR were positively correlated (r = 0.68, P < 0.05). T2 measurements were robust to interobserver (intraclass correlation 0.89) and intrasubject variability (Bland-Altman bias of 0.005 seconds, 95% confidence interval [CI] -0.04 to +0.05 seconds, and 0.0006 seconds, 95% CI -0.05 to +0.06 seconds). DATA CONCLUSION: MR measures of small bowel wall T2 were significantly increased following indomethacin provocation and correlated with 2-hour LMR test results. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY STAGE: 2.


Asunto(s)
Intestino Delgado , Imagen por Resonancia Magnética , Humanos , Intestino Delgado/diagnóstico por imagen , Permeabilidad , Estudios Prospectivos , Reproducibilidad de los Resultados
3.
Eur Radiol ; 31(2): 775-784, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32833090

RESUMEN

OBJECTIVES: Investigate the relationship between quantified terminal ileal (TI) motility and histopathological activity grading, Crohn Disease MRI Index (CDMI) and faecal calprotectin. METHODS: Retrospective review of children with Crohn disease or unclassified inflammatory bowel disease, who underwent MR enterography. Dynamic imaging for 25 patients (median age 12, range 5 to 16) was analysed with a validated motility algorithm. The TI motility score was derived. The primary reference standard was TI Endoscopic biopsy Assessment of Inflammatory Activity (eAIS) within 40 days of the MR enterography. Secondary reference standards: (1) the Crohn Disease MRI Index (CDMI) and (2) faecal calprotectin levels. RESULTS: MR enterography median motility score was 0.17 a.u. (IQR 0.12 to 0.25; range 0.05 to 0.55), and median CDMI was 3 (IQR 0 to 5.5). Forty-three percent of patients had active disease (eAIS > 0) with a median eAIS score of 0 (IQR 0 to 2; range 0 to 5). The correlation between eAIS and motility was r = - 0.58 (p = 0.004, N = 23). Between CDMI and motility, r = - 0.42 (p = 0.037, N = 25). Motility score was lower in active disease (median 0.12 vs 0.21, p = 0.020) while CDMI was higher (median 5 vs 1, p = 0.04). In a subset of 12 patients with faecal calprotectin within 3 months of MR enterography, correlation with motility was r = - 0.27 (p = 0.4). CONCLUSIONS: Quantified terminal ileum motility decreases with increasing histopathological abnormality in children with Crohn disease, reproducing findings in adults. TI motility showed a negative correlation with an MRI activity score but not with faecal calprotectin levels. KEY POINTS: • It is feasible to perform MRI quantified bowel motility assessment in children using free-breathing techniques. • Bowel motility in children with Crohn disease decreases as the extent of intestinal inflammation increases. • Quantified intestinal motility may be a candidate biomarker for treatment efficacy in children with Crohn disease.


Asunto(s)
Enfermedad de Crohn , Adulto , Niño , Enfermedad de Crohn/diagnóstico por imagen , Estudios de Factibilidad , Humanos , Íleon/diagnóstico por imagen , Imagen por Resonancia Magnética , Estudios Retrospectivos
4.
Radiology ; 289(2): 428-435, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30129901

RESUMEN

Purpose To evaluate the accuracy of MRI-quantified small bowel motility for Crohn disease activity against endoscopic and histopathologic reference standards. Materials and Methods For this prospective study, 82 participants (median age, 31 years; range, 16 to 70 years; 42 males [median age, 31 years; range, 17 to 70 years] and 40 females [median age, 31 years; range, 16 to 63 years) underwent colonoscopy and MR enterography within 14 days (from October 2011 to March 2014) at two centers. The Crohn disease endoscopic index of severity (CDEIS), histopathologic activity score (endoscopic biopsy acute histologic inflammatory score [EAIS]), and MR index of activity (MaRIA) were scored in the terminal ileum. Terminal ileal motility was quantified by using an image registration based-motility assessment algorithm (hereafter, Motility). Sensitivity and specificity of Motility (˂0.3 arbitrary units) and MaRIA (≥7 and ≥11) for disease activity (CDEIS ≥4 or EAIS ≥1) were compared by using the McNemar test. Receiver operating characteristic curves were constructed and areas under the curve were compared. Motility was correlated with reference standards by using Spearman rank estimates. Results Terminal ileal Motility was negatively correlated with EAIS (r =-0.61; 95% confidence interval [CI]: 0.7, -0.5) and CDEIS (r = -0.59; 95% CI: 0.7, -0.4). With CDEIS as the standard of reference, Motility had higher sensitivity than did MaRIA (≥11) (93% vs 78%, respectively; P = .03), but lower specificity (61% vs 81%, respectively; P = .04). With EAIS as the standard of reference, Motility had higher sensitivity than did MaRIA (≥7) (92% vs 75%, respectively; P = .03) but similar specificity (71% vs 74%, respectively; P >.99). The area under the receiver operating characteristic curve for Motility was 0.86 and 0.87 with CDEIS and EAIS as the standard of reference, respectively. Conclusion The terminal ileal Motility score showed good agreement with endoscopic and histopathologic activity in Crohn disease. © RSNA, 2018 Online supplemental material is available for this article.


Asunto(s)
Enfermedad de Crohn/diagnóstico por imagen , Enfermedad de Crohn/fisiopatología , Íleon/diagnóstico por imagen , Íleon/fisiopatología , Imagen por Resonancia Magnética/métodos , Adolescente , Adulto , Anciano , Biomarcadores , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad , Adulto Joven
5.
Eur Radiol ; 27(2): 598-606, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27085701

RESUMEN

OBJECTIVE: Determine feasibility of vocal fold (VF) abduction and adduction assessment by cine magnetic resonance imaging (cine-MRI) METHODS: Cine-MRI of the VF was performed on five healthy and nine unilateral VF paralysis (UVFP) participants using an axial gradient echo acquisition with temporal resolution of 0.7 s. VFs were continuously imaged with cine-MRI during a 10-s period of quiet respiration and phonation. Scanning was repeated twice within an individual session and then once again at a 1-week interval. Asymmetry of VF position during phonation (VF phonation asymmetry, VFPa) and respiration (VF respiration asymmetry, VFRa) was determined. Percentage reduction in total glottal area between respiration and phonation (VF abduction potential, VFAP) was derived to measure overall mobility. An un-paired t-test was used to compare differences between groups. Intra-session, inter-session and inter-reader repeatability of the quantitative metrics was evaluated using intraclass correlation coefficient (ICC). RESULTS: VF position asymmetry (VFPa and VFRa) was greater (p=0.012; p=0.001) and overall mobility (VFAP) was lower (p=0.008) in UVFP patients compared with healthy participants. ICC of repeatability of all metrics was good, ranged from 0.82 to 0.95 except for the inter-session VFPa (0.44). CONCLUSION: Cine-MRI is feasible for assessing VF abduction and adduction. Derived quantitative metrics have good repeatability. KEY POINTS: • Cine-MRI is used to assess vocal folds (VFs) mobility: abduction and adduction. • New quantitative metrics are derived from VF position and abduction potential. • Cine-MRI able to depict the difference between normal and abnormal VF mobility. • Cine-MRI derived quantitative metrics have good repeatability.


Asunto(s)
Imagen por Resonancia Cinemagnética/métodos , Parálisis de los Pliegues Vocales/diagnóstico por imagen , Pliegues Vocales/diagnóstico por imagen , Adulto , Estudios de Factibilidad , Femenino , Humanos , Masculino , Fonación , Reproducibilidad de los Resultados
6.
J Magn Reson Imaging ; 44(2): 277-87, 2016 08.
Artículo en Inglés | MEDLINE | ID: mdl-26801196

RESUMEN

PURPOSE: To study the feasibility and to gauge the potential clinical impact of quantifying small bowel motility using magnetic resonance imaging (MRI) in a larger population with a spectra of gastrointestinal conditions with impaired small bowel motility. MATERIALS AND METHODS: Data were gathered retrospectively from a cohort of 127 patients undergoing MR enterography (1.5 Tesla) in 2011. Cine motility sequences were processed with validated motility analysis software and a parametric motility map was generated. Regions of interests were drawn in the jejunum, ileum, and terminal ileum, and Jacobian standard deviation mean motility index' score (MIS) was calculated. Patients were divided into Crohn's disease (CD), ulcerative colitis, irritable bowel syndrome, and healthy subjects. RESULTS: In CD, terminal ileum motility was lower in comparison to healthy subjects (mean difference: -0.1052 arbitrary units, 95% confidence interval: -0.1981--0.0122, P = 0.018). Subgrouping of CD showed that the difference was recognized in patients with disease limited to the small bowel (mean difference: -0.1440 arbitrary units, 95% confidence interval: -0.2491--0.0389, P = 0.002). Visible dysmotility of terminal ileum on MRI reflected a reduced MIS compared with normal motility (0.22 ± 0.09 and 0.33 ± 0.15 arbitrary units, respectively, P = 0.043). Motility correlated negatively between ileum and age (P = 0.021), and between terminal ileum and C-reactive protein in ulcerative colitis (P = 0.031). CONCLUSION: Motility quantitation revealed a significant difference in motility of terminal ileum in patients with small bowel CD compared with healthy subjects, concording with visible dysmotility and inflammatory changes. J. Magn. Reson. Imaging 2016;44:277-287.


Asunto(s)
Motilidad Gastrointestinal , Interpretación de Imagen Asistida por Computador/métodos , Enfermedades Inflamatorias del Intestino/diagnóstico por imagen , Enfermedades Inflamatorias del Intestino/fisiopatología , Intestino Delgado/diagnóstico por imagen , Intestino Delgado/fisiopatología , Imagen por Resonancia Cinemagnética/métodos , Adulto , Algoritmos , Estudios de Factibilidad , Femenino , Humanos , Aumento de la Imagen/métodos , Síndrome del Colon Irritable/diagnóstico por imagen , Síndrome del Colon Irritable/fisiopatología , Masculino , Proyectos Piloto , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
7.
Radiology ; 269(2): 443-50, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23801770

RESUMEN

PURPOSE: To assess the repeatability in human volunteers of software-quantified small bowel motility captured with magnetic resonance (MR) imaging and to test the ability to detect changes in motility induced by pharmacologic agents. MATERIALS AND METHODS: The study was approved by the Royal Free Research Ethics Committee, and all subjects gave full written informed consent. Twenty-one healthy volunteers (14 men, seven women; mean age, 28 years) underwent cine MR imaging with a three-dimensional balanced turbo field-echo sequence to capture small bowel motility. Volume blocks (15 cm thick) were acquired every second during a 20-second breath hold. A randomized, blinded, placebo-controlled crossover study of either 0.5 mg neostigmine or saline (n = 11) or 20 mg intravenous butylscopolamine or saline (n = 10) was performed with motility MR imaging at baseline and repeated at a mean of 4 weeks (range, 2-7 weeks). Two readers independently drew regions of interest around the small bowel, and motility was quantified by using a registration algorithm that provided a global motility metric in arbitrary units. Repeatability of the motility measurements at baseline was assessed by using Bland-Altman and within-subject coefficient of variation measures. Changes in mean motility measurements after drug administration were compared with those after placebo administration by using paired t testing. RESULTS: The repeatability between baseline measurements of motility was high; the Bland-Altman mean difference was -0.0025 (range, 0.28-0.4), the 95% limit of agreement was ±0.044 arbitrary units (au), and the within-subject coefficient of variation was 4.9%. Measured motility with neostigmine (mean, 0.39 au) was significantly higher than that with placebo (mean, 0.34 au; P < .001), whereas that with butylscopolamine (mean, 0.13 au) was significantly lower than that with placebo (mean, 0.30 au; P < .001). CONCLUSION: Quantification of small bowel motility with use of MR imaging in healthy volunteers is repeatable and sensitive to changes induced by means of pharmacologic manipulation. SUPPLEMENTAL MATERIAL: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.13130151/-/DC1.


Asunto(s)
Bromuro de Butilescopolamonio/farmacología , Motilidad Gastrointestinal/efectos de los fármacos , Intestino Delgado , Imagen por Resonancia Cinemagnética/métodos , Neostigmina/farmacología , Parasimpatolíticos/farmacología , Parasimpaticomiméticos/farmacología , Adulto , Algoritmos , Bromuro de Butilescopolamonio/administración & dosificación , Estudios Cruzados , Femenino , Humanos , Imagenología Tridimensional , Masculino , Neostigmina/administración & dosificación , Parasimpatolíticos/administración & dosificación , Parasimpaticomiméticos/administración & dosificación , Placebos , Reproducibilidad de los Resultados
8.
NIHR Open Res ; 3: 65, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-39139270

RESUMEN

Background: People with cystic fibrosis (CF) can experience recurrent chest infections, pancreatic exocrine insufficiency and gastrointestinal symptoms. New cystic fibrosis transmembrane conductance regulator (CFTR) modulator drugs improve lung function but gastrointestinal effects are unclear. We aimed to see if a CFTR modulator (tezacaftor-ivacaftor,TEZ/IVA) improves gastrointestinal outcomes in CF. Methods: We conducted a randomised, double-blind, placebo-controlled, two-period crossover trial (2019-2020) at Nottingham University Hospitals. The effects of TEZ/IVA on gut physiology were measured using MRI. Participants were randomly assigned to treatment sequences AB or BA (A:TEZ/IVA, B:placebo, each 28 days), with a 28-day washout period. Participants had serial MRI scans at baseline and after 19-23 days of each treatment. Due to the COVID-19 pandemic, a protocol amendment allowed for observer-blind comparisons prior to and during TEZ/IVA. In such cases, participants were not blind to the treatment but researchers remained blind. The primary outcome was oro-caecal transit time (OCTT). Secondary outcomes included MRI metrics, symptoms and stool biomarkers. Results: We randomised 13 participants. Before the COVID-19 pandemic 8 participants completed the full protocol and 1 dropped out. The remaining 4 participants followed the amended protocol. There were no significant differences between placebo and TEZ/IVA for OCTT (TEZ/IVA >360minutes [225,>360] vs. placebo 330minutes [285,>360], p=0.8) or secondary outcomes. There were no adverse events. Conclusions: Our data contribute to a research gap in the extra-pulmonary effects of CFTR modulators. We found no effect after TEZ/IVA on MRI metrics of gut function, GI symptoms or stool calprotectin. Effects might be detectable with larger studies, longer treatment or more effective CFTR modulators. ClinicalTrialsgov registration: NCT04006873 (02/07/2019).

9.
Magn Reson Med ; 68(3): 783-93, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22234983

RESUMEN

Evaluation of small bowel motility from two-dimensional dynamic MRI is of increasing interest for the assessment of segmental diseases such as Crohn's disease. We propose to use nonrigid image registration for automated motility analysis. Registration is particularly difficult when localized intensity changes occur (e.g., due to intraluminal flow or through-plane motion). Therefore, displacements were extracted using a joint registration and modeling of intensity changes. Results were analyzed in 10 patients with known or suspected Crohn's disease. Bowel wall displacements were assessed by tracking bowel cross-sectional markers over time. Automated tracking with the proposed technique was in good agreement with manual tracking (similar bias, improved standard deviations). The ability to quantify different grades of bowel motility was investigated by comparing direct motion measures (i.e., changes in bowel cross-sectional diameter or area) and various parametric maps, e.g., based on the Jacobian of the measured displacements with expert grading. Among these measures, the standard deviation over time of the Jacobian was the best at predicting grades from 1 (moving normally) to 4 (not moving at all) in 50 bowel regions with normal and pathologically reduced motility, yielding 93% correct classification with a 1-class tolerance (i.e., same score as the expert ± 1).


Asunto(s)
Enfermedad de Crohn/patología , Enfermedad de Crohn/fisiopatología , Motilidad Gastrointestinal , Intestino Delgado/patología , Intestino Delgado/fisiopatología , Imagen por Resonancia Magnética/métodos , Técnica de Sustracción , Algoritmos , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
10.
Eur Radiol ; 22(11): 2494-501, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22661057

RESUMEN

OBJECTIVE: To compare quantified terminal ileal (TI) motility during MR enterography (MRE) with histopathological severity of acute inflammation in Crohn's disease. METHODS: A total of 28 Crohn's patients underwent MRE and endoscopic TI biopsy. Axial and coronal TrueFISP, HASTE and post-gadolinium VIBE images were supplemented by multiple coronal TrueFISP cine motility sequences through the small bowel volume. TI motility index (MI) was quantified using validated software; an acute inflammation score (eAIS; 0-6) was assigned to the biopsy. Two observers qualitatively scored mural thickness, T2 signal, contrast enhancement and perimural oedema (0-3) to produce an activity score (aMRIs) based on anatomical MRI. The association among the MI, eAIS and aMRIs was tested using Spearman's rank correlation. Wilcoxon rank sum test compared motility in subjects with and without histopathological inflammation. RESULTS: Mean MI and mean eAIS were 0.27 (range 0.06-0.55) and 1.5 (range 0-5), respectively. There was a significant difference in MI between non-inflamed (mean 0.37, range 0.13-0.55) and inflamed (mean 0.19, range 0.06-0.44) TI, P = 0.002, and a significant negative correlation between MI and both eAIS (Rho = -0.52, P = 0.005) and aMRIs (R = -0.7, P < 0.001). CONCLUSION: Quantified TI motility negatively correlates with histopathological measures of disease activity and existing anatomical MRI activity biomarkers. KEY POINTS: • Magnetic resonance imaging is increasingly used to assess Crohn's disease. • MRI measurements can provide a quantitative assessment of small bowel motility. • MR enterography can grade Crohn's disease. • Small bowel motility can be used as a marker of inflammatory activity.


Asunto(s)
Enfermedad de Crohn/diagnóstico , Enfermedad de Crohn/metabolismo , Intestinos/patología , Imagen por Resonancia Magnética/métodos , Adolescente , Adulto , Anciano , Algoritmos , Biomarcadores/metabolismo , Estudios de Cohortes , Diagnóstico por Imagen/métodos , Endoscopía/métodos , Femenino , Motilidad Gastrointestinal , Humanos , Inflamación , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Programas Informáticos
11.
BJR Open ; 4(1): 20210049, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36105419

RESUMEN

Objectives: To evaluate the effect of bowel dilation on cine-MRI small bowel motility measurements, by comparing a conventional motility score (including bowel wall and lumen) with a bowel wall-specific motility score in healthy and diseased populations. Methods: Four populations were included: 10 Crohn's patients with a stricture and prestricture dilation for segmental motility analysis, and 14 mannitol-prepared healthy subjects, 15 fasted healthy subjects and eight chronic intestinal pseudo-obstruction (CIPO) patients (characterized by dilated bowel loops) for global small bowel motility analysis. All subjects underwent a cine-MRI scan from which two motility scores were calculated: a conventional score (including bowel wall and lumen) and a bowel wall-specific score. The difference between the two scores was calculated per population and compared between groups with a one-way ANOVA and Tukey-Kramer analysis. Results: In Crohn's patients, the median (IQR) change between the conventional and wall-specific motility score was 0% (-2 to +4%) within the stricture and 0% (-1 to +7%) in the prestricture dilation. For the global small bowel, this was -1% (-5 to 0%) in mannitol-prepared healthy subjects, -2% (-6 to +2%) in fasted healthy subjects and +14% (+6 to+20%) in CIPO patients. The difference between the two motility scores in CIPO patients differed significantly from the four other groups (p = 0.002 to p < 0.001). Conclusions: The conventional small bowel motility score seems robust in Crohn's disease patients and healthy subjects. In patients with globally and grossly dilated bowel loops, a bowel-wall specific motility score may give a better representation of small bowel motility. Advances in knowledge: These findings support researchers and clinicians with making informed choices for using cine-MRI motility analysis in different populations.

12.
Neurogastroenterol Motil ; 34(10): e14381, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35438218

RESUMEN

BACKGROUND: Gastrointestinal symptoms in functional gut disorders occur without any discernible structural gut abnormality. Preliminary observations on enteric MRI suggest possible abnormal content and motility of the terminal ileum (TI) in constipation-predominant IBS (IBS-C) with severe bloating, and in functional bloating and distension (FABD) patients. We investigated whether MRI can quantify differences in small bowel (SB) content and motility between patients and healthy controls (HCs). METHODS: 11 IBS-C (mean age 40 [21-52] years; 10 women) and 7 FABD (36 [21-56]; all women) patients with bloating and 20 HCs (28 [22-48]; 6 women) underwent enteric MRI, including dynamic motility and anatomical sequences. Three texture analysis (TA) parameters assessed the homogeneity of the luminal content, with ratios calculated between the TI and (1) the SB and (2) the ascending colon. Four TI motility metrics were derived. Ascending colon diameter (ACD) was measured. A comparison between HCs and patients was performed independently for: (1) three TA parameters, (2) four TI motility metrics, and (3) ACD. KEY RESULTS: Compared with HCs, patients had TI:colon ratios higher for TA contrast (p < 0.001), decreased TI motility (lower mean motility [p = 0.04], spatial motility variation [p = 0.03], and area of motile TI [p = 0.03]), and increased ACD (p = 0.001). CONCLUSIONS AND INFERENCES: IBS-C and FABD patients show reduced TI motility and differences in luminal content compared with HCs. This potentially indicates reflux of colonic contents or delayed clearance of the TI, which alongside increased ACD may contribute to symptoms of constipation and bloating.


Asunto(s)
Enfermedades Gastrointestinales , Síndrome del Colon Irritable , Adulto , Estreñimiento/diagnóstico por imagen , Femenino , Flatulencia , Enfermedades Gastrointestinales/diagnóstico por imagen , Humanos , Intestino Delgado/diagnóstico por imagen , Síndrome del Colon Irritable/diagnóstico por imagen , Imagen por Resonancia Magnética
13.
J Cyst Fibros ; 21(3): 502-505, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34922853

RESUMEN

People with cystic fibrosis (CF) experience digestive symptoms but the mechanisms are incompletely understood. Here we explore causes and consequences of slower gastrointestinal transit using magnetic resonance imaging (MRI). Twelve people with CF and 12 healthy controls, matched for age and gender, underwent MRI scans, both fasted and after standardised meals, over 6.5 h. Fasted small bowel motility scores were lower in CF than in controls. No difference in ascending colon chyme T1 was detected. The difference in texture between small bowel and colon contents, seen in health, was diminished in CF. The ascending colon in CF participants had an abnormal appearance compared to controls. MRI offers unique potential to evaluate gut luminal content, colonic mucosa and intestinal motor activity. These new data support the theoretical cycle of desiccation, dysmotility and delayed transit as a cause of gastrointestinal symptoms in CF.


Asunto(s)
Fibrosis Quística , Motilidad Gastrointestinal , Tracto Gastrointestinal , Tránsito Gastrointestinal , Humanos , Imagen por Resonancia Magnética
14.
Top Magn Reson Imaging ; 30(1): 31-41, 2021 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-33528210

RESUMEN

ABSTRACT: In this review article, we present the latest developments in quantitative imaging biomarkers based on magnetic resonance imaging (MRI), applied to the diagnosis, assessment of response to therapy, and assessment of prognosis of Crohn disease. We also discuss the biomarkers' limitations and future prospects. We performed a literature search of clinical and translational research in Crohn disease using diffusion-weighted MRI (DWI-MRI), dynamic contrast-enhanced MRI (DCE-MRI), motility MRI, and magnetization transfer MRI, as well as emerging topics such as T1 mapping, radiomics, and artificial intelligence. These techniques are integrated in and combined with qualitative image assessment of magnetic resonance enterography (MRE) examinations. Quantitative MRI biomarkers add value to MRE qualitative assessment, achieving substantial diagnostic performance (area under receiver-operating curve = 0.8-0.95). The studies reviewed show that the combination of multiple MRI sequences in a multiparametric quantitative fashion provides rich information that may help for better diagnosis, assessment of severity, prognostication, and assessment of response to biological treatment. However, the addition of quantitative sequences to MRE examinations has potential drawbacks, including increased scan time and the need for further validation before being used in therapeutic drug trials as well as the clinic.


Asunto(s)
Enfermedad de Crohn/diagnóstico por imagen , Enfermedad de Crohn/metabolismo , Imagen por Resonancia Magnética/métodos , Inteligencia Artificial , Biomarcadores/metabolismo , Medios de Contraste , Enfermedad de Crohn/patología , Humanos
15.
Abdom Radiol (NY) ; 46(10): 4660-4670, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34148103

RESUMEN

PURPOSE: MR elastography and magnetization-tagging use liver stiffness (LS) measurements to diagnose fibrosis but require physical drivers, specialist sequences and post-processing. Here we evaluate non-rigid registration of dynamic two-dimensional cine MRI images to measure cardiac-induced liver deformation (LD) as a measure of LS by (i) assessing preclinical proof-of-concept, (ii) clinical reproducibility and inter-reader variability, (iii) the effects of hepatic hemodynamic changes and (iv) feasibility in patients with cirrhosis. METHODS: Sprague-Dawley rats (n = 21 bile duct ligated (BDL), n = 17 sham-operated controls) and fasted patients with liver cirrhosis (n = 11) and healthy volunteers (HVs, n = 10) underwent spoiled gradient-echo short-axis cardiac cine MRI studies at 9.4 T (rodents) and 3.0 T (humans). LD measurements were obtained from intrahepatic sub-cardiac regions-of-interest close to the diaphragmatic margin. One-week reproducibility and prandial stress induced hemodynamic changes were assessed in healthy volunteers. RESULTS: Normalized LD was higher in BDL (1.304 ± 0.062) compared with sham-operated rats (1.058 ± 0.045, P = 0.0031). HV seven-day reproducibility Bland-Altman (BA) limits-of-agreement (LoAs) were ± 0.028 a.u. and inter-reader variability BA LoAs were ± 0.030 a.u. Post-prandial LD increases were non-significant (+ 0.0083 ± 0.0076 a.u., P = 0.3028) and uncorrelated with PV flow changes (r = 0.42, p = 0.2219). LD measurements successfully obtained from all patients were not significantly higher in cirrhotics (0.102 ± 0.0099 a.u.) compared with HVs (0.080 ± 0.0063 a.u., P = 0.0847). CONCLUSION: Cardiac-induced LD is a conceptually reasonable approach from preclinical studies, measurements demonstrate good reproducibility and inter-reader variability, are less likely to be affected by hepatic hemodynamic changes and are feasible in patients with cirrhosis.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Cirrosis Hepática , Animales , Estudios de Factibilidad , Humanos , Hígado/diagnóstico por imagen , Hígado/patología , Cirrosis Hepática/diagnóstico por imagen , Cirrosis Hepática/patología , Ratas , Ratas Sprague-Dawley , Reproducibilidad de los Resultados
16.
Am J Clin Nutr ; 111(1): 131-140, 2020 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-31557279

RESUMEN

BACKGROUND: Crohn's disease (CD) patients suffer postprandial aversive symptoms, which can lead to anorexia and malnutrition. Changes in the regulation of gut hormones and gut dysmotility are believed to play a role. OBJECTIVES: This study aimed to investigate small-bowel motility and gut peptide responses to a standard test meal in CD by using MRI. METHODS: We studied 15 CD patients with active disease (age 36 ± 3 y; BMI 26 ± 1 kg/m 2) and 20 healthy volunteers (HVs; age 31 ± 3 years; BMI 24 ± 1 kg/m 2). They underwent baseline and postprandial MRI scans, symptom questionnaires, and blood sampling following a 400-g soup meal (204 kcal). Small-bowel motility, other MRI parameters, and glucagon-like peptide-1 (GLP-1), polypeptide YY (PYY), and cholecystokinin peptides were measured. Data are presented as means ± SEMs. RESULTS: HVs had significantly higher fasting motility indexes [106 ± 13 arbitrary units (a.u.)], compared with CD participants (70 ± 8 a.u.; P ≤ 0.05). Postprandial small-bowel water content showed a significant time by group interaction (P < 0.05), with CD participants showing higher levels from 210 min postprandially. Fasting concentrations of GLP-1 and PYY were significantly greater in CD participants, compared with HVs [GLP-1, CD 50 ± 8 µg/mL versus HV 13 ± 3 µg/mL (P ≤ 0.0001); PYY, CD 236 ± 16 pg/mL versus HV 118 ± 12 pg/mL (P ≤ 0.0001)]. The meal challenge induced a significant postprandial increase in aversive symptom scores (fullness, distention, bloating, abdominal pain, and sickness) in CD participants compared with HVs (P ≤ 0.05). CONCLUSIONS: The decrease in fasting small-bowel motility noted in CD participants can be ascribed to the increased fasting gut peptides. A better understanding of the etiology of aversive symptoms in CD will facilitate identification of better therapeutic targets to improve nutritional status. This trial was registered at clinicaltrials.gov as NCT03052465.


Asunto(s)
Enfermedad de Crohn/metabolismo , Enfermedad de Crohn/fisiopatología , Hormonas Gastrointestinales/sangre , Intestino Delgado/fisiopatología , Adulto , Anciano , Colecistoquinina/sangre , Enfermedad de Crohn/diagnóstico por imagen , Ayuno/metabolismo , Femenino , Motilidad Gastrointestinal , Péptido 1 Similar al Glucagón/sangre , Humanos , Intestino Delgado/diagnóstico por imagen , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Péptido YY/sangre , Periodo Posprandial , Adulto Joven
17.
Neurogastroenterol Motil ; 32(11): e13942, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32677154

RESUMEN

BACKGROUND: Magnetic resonance imaging (MRI) of the colonic response to a macrogol challenge drink can be used to assess the mechanisms underlying severe constipation. We measured the intrasubject reproducibility of MRI measures of colonic function to aid their implementation as a possible clinical test. METHODS: Healthy participants attended for MRI on two occasions (identical protocols, minimum 1 week apart). They underwent a fasted scan and then consumed the macrogol drink. Subjects were scanned at 60 and 120 minutes, with maximum value reached used for comparison. The colonic volume, water content, mixing of colonic content and the movement of the colon walls were measured. Coefficients of variation and intraclass correlation coefficients (ICC) were calculated. RESULTS: Twelve participants completed the study: nine female, mean age 26 years (SD 5) and body mass index 24.8 kg/m2 (SD 3.2). All measures consistently increased above baseline following provocation with macrogol. The volume, water content and content mixing had good intrasubject reproducibility (ICC volume = 0.84, water content = 0.93, mixing = 0.79, P < .001). With the wall movement, the response to the challenge was generally large, but more variable between visits resulting in a lower ICC overall (ascending colon = 0.65, descending colon = 0.76, P < .001). CONCLUSIONS: The colonic response to the macrogol stimulus as assessed by MRI is heterogeneous but large compared to baseline, with moderate to good reproducibility, making the test suitable to study potential pathologies underlying GI disorders such as constipation. More data are needed to better define the normal range for comparison with patient groups who may have both hypo- and hypermotile responses.


Asunto(s)
Colon/diagnóstico por imagen , Colon/fisiología , Motilidad Gastrointestinal , Polietilenglicoles , Tensoactivos , Adulto , Colon/fisiopatología , Estreñimiento/fisiopatología , Femenino , Voluntarios Sanos , Humanos , Imagen por Resonancia Magnética , Masculino , Tamaño de los Órganos , Proyectos Piloto , Reproducibilidad de los Resultados , Agua , Adulto Joven
18.
Nutrients ; 12(7)2020 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-32707726

RESUMEN

(1) Background: Intestinal failure-associated liver disease (IFALD) in adults is characterized by steatosis with variable progression to fibrosis/cirrhosis. Reference standard liver biopsy is not feasible for all patients, but non-invasive serological and quantitative MRI markers for diagnosis/monitoring have not been previously validated. Here, we examine the potential of serum scores and feasibility of quantitative MRI used in non-IFALD liver diseases for the diagnosis of IFALD steatosis; (2) Methods: Clinical and biochemical parameters were used to calculate serum scores in patients on home parenteral nutrition (HPN) with/without IFALD steatosis. A sub-group underwent multiparameter quantitative MRI measurements of liver fat fraction, iron content, tissue T1, liver blood flow and small bowel motility; (3) Results: Compared to non-IFALD (n = 12), patients with IFALD steatosis (n = 8) demonstrated serum score elevations in Enhanced Liver Fibrosis (p = 0.032), Aspartate transaminase-to-Platelet Ratio Index (p < 0.001), Fibrosis-4 Index (p = 0.010), Forns Index (p = 0.001), Gamma-glutamyl transferase-to-Platelet Ratio Index (p = 0.002) and Fibrosis Index (p = 0.001). Quantitative MRI scanning was feasible in all 10 sub-group patients. Median liver fat fraction was higher in IFALD steatosis patients (10.9% vs 2.1%, p = 0.032); other parameter differences were non-significant; (4) Conclusion: Serum scores used for non-IFALD liver diseases may be useful in IFALD steatosis. Multiparameter MRI is feasible in patients on HPN.


Asunto(s)
Hígado Graso/diagnóstico , Hígado Graso/etiología , Enfermedades Intestinales/complicaciones , Imagen por Resonancia Magnética , Tejido Adiposo/metabolismo , Adulto , Anciano , Aspartato Aminotransferasas/sangre , Biomarcadores/sangre , Estudios de Cohortes , Estudios Transversales , Hígado Graso/patología , Estudios de Factibilidad , Femenino , Humanos , Hígado/diagnóstico por imagen , Hígado/metabolismo , Hígado/patología , Masculino , Persona de Mediana Edad , Nutrición Parenteral en el Domicilio , Recuento de Plaquetas , gamma-Glutamiltransferasa/sangre
19.
PLoS One ; 15(11): e0241441, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33175860

RESUMEN

OBJECTIVE: The gastrointestinal environment in which drug products need to disintegrate before the drug can dissolve and be absorbed has not been studied in detail due to limitations, especially invasiveness of existing techniques. Minimal in vivo data is available on undisturbed gastrointestinal motility to improve relevance of predictive dissolution models and in silico tools such as physiologically-based pharmacokinetic models. Recent advances in magnetic resonance imaging methods could provide novel data and insights that can be used as a reference to validate and, if necessary, optimize these models. The conventional method for measuring gastrointestinal motility is via a manometric technique involving intubation. Nevertheless, it is feasible to measure gastrointestinal motility with magnetic resonance imaging. The aim of this study was is to develop and validate a magnetic resonance imaging method using the most recent semi-automated analysis method against concomitant perfused manometry method. MATERIAL AND METHODS: Eighteen healthy fasted participants were recruited for this study. The participants were intubated with a water-perfused manometry catheter. Subsequently, stomach motility was assessed by cine-MRI acquired at intervals, of 3.5min sets, at coronal oblique planes through the abdomen and by simultaneous water perfused manometry, before and after administration of a standard bioavailability / bioequivalence 8 ounces (~240mL) drink of water. The magnetic resonance imaging motility images were analysed using Spatio-Temporal Motility analysis STMM techniques. The area under the curve of the gastric motility contractions was calculated for each set and compared between techniques. The study visit was then repeated one week later. RESULTS: Data from 15 participants was analysed. There was a good correlation between the MRI antral motility plots area under the curve and corresponding perfused manometry motility area under the curve (r = 0.860) during both antral contractions and quiescence. CONCLUSION: Non-invasive dynamic magnetic resonance imaging of gastric antral motility coupled with recently developed, semi-automated magnetic resonance imaging data processing techniques correlated well with simultaneous, 'gold standard' water perfused manometry. This will be particularly helpful for research purposes related to oral absorption where the absorption of a drug is highly depending on the underlying gastrointestinal processes such as gastric emptying, gastrointestinal motility and availability of residual fluid volumes. CLINICAL TRIAL: This trial was registered at ClinicalTrials.gov as NCT03191045.


Asunto(s)
Ayuno/fisiología , Motilidad Gastrointestinal/fisiología , Voluntarios Sanos , Imagen por Resonancia Magnética , Manometría , Antro Pilórico/diagnóstico por imagen , Antro Pilórico/fisiología , Agua/farmacología , Adulto , Área Bajo la Curva , Disponibilidad Biológica , Femenino , Motilidad Gastrointestinal/efectos de los fármacos , Humanos , Masculino , Persona de Mediana Edad , Contracción Muscular/fisiología , Antro Pilórico/efectos de los fármacos , Equivalencia Terapéutica , Factores de Tiempo , Adulto Joven
20.
Neurogastroenterol Motil ; 31(5): e13557, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30821098

RESUMEN

BACKGROUND: MRI is increasingly used to objectively assess gastrointestinal motility. However, motility metrics often do not offer insights into the nature of contractile action. This study introduces a systematic method of making spatio-temporal measurements of contractions, based on changes in bowel lumen diameter. METHODS: Two heterogeneous cohorts of subjects were selected displaying gastric (n = 15) and colonic motility (n = 20) on which to test the spatio-temporal motility MRI (STMM) technique. STMM involved delineating the bowel lumen along with inner and outer bowel wall along a section of the gastrointestinal tract. A series of diameter measurements were made automatically across the central axis of the lumen. Measurements were automatically propagated through the time series using a previously validated algorithm. Contractions were quantitatively summarized with two methods measuring (a) normalized contraction plot (NCP) and (b) combined velocity distance (CVD) both of which can be visualized as spatio-temporal motility maps. Both metrics were correlated against subjective visual scoring systems. KEY RESULTS: Good correlation was seen between reader scores and both motility metrics (NCP, R = 0.85, P < 0.001, CVD, R = 0.93, R < 0.001) in the gastric data. Good correlation was also seen between the reader scores and the two metrics in the colonic data (NCP, R = 0.82, P < 0.001, CVD, R = 0.78, R < 0.001). CONCLUSIONS AND INFERENCES: Spatio-temporal motility MRI analysis of the stomach and colon correlates well with reader scores in a range of datasets and provides both a quantitative and qualitative means of assessing contractile activity in the gastrointestinal tract.


Asunto(s)
Colon , Motilidad Gastrointestinal , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Estómago , Adulto , Femenino , Humanos , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA