Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Transl Med ; 5: 15, 2007 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-17359531

RESUMEN

BACKGROUND: Treatment records and follow-up data on 40 patients with primary and metastatic liver malignancies who underwent a single whole-liver treatment with Y-90 resin microspheres (SIR-Spheres Sirtex Medical, Lake Forest, IL) were retrospectively reviewed. The objective of the study was to evaluate the anatomic and physiologic determinants of radiation dose distribution, and the dose response of tumor and liver toxicity in patients with liver malignancies who underwent hepatic arterial Y-90 resin microsphere treatment. METHODS: Liver and tumor volume calculations were performed on pre-treatment CT scans. Fractional tumor and liver flow characteristics and lung shunt fractions were determined using hepatic arterial Tc-99m MAA imaging. Absorbed dose calculations were performed using the MIRD equations. Liver toxicity was assessed clinically and by liver function tests. Tumor response to therapy was assessed by CT and/or tumor markers. RESULTS: Of the 40 patients, 5 had hepatocellular cancer (HCC), and 35 had metastatic liver tumors (15 colorectal cancer, 10 neuroendocrine tumors, 4 breast cancer, 2 lung cancer, 1 ovarian cancer, 1 endometrial cancer, and 2 unknown primary adenocarcinoma). All patients were treated in a salvage setting with a 3 to 80 week follow-up (mean: 19 weeks). Tumor volumes ranged from 15.0 to 984.2 cc (mean: 294.9 cc) and tumor to normal liver uptake ratios ranged from 2.8 to 15.4 (mean: 5.4). Average administered activity was 1.2 GBq (0.4 to 2.4 GBq). Liver absorbed doses ranged from 0.7 to 99.5 Gy (mean: 17.2 Gy). Tumor absorbed doses ranged from 40.1 to 494.8 Gy (mean: 121.5 Gy). None of the patients had clinical venoocclusive disease or therapy-induced liver failure. Seven patients (17.5 %) had transient and 7 patients (17.5 %) had persistent LFT abnormalities. There were 27 (67.5%) responders (complete response, partial response, and stable disease). Tumor response correlated with higher tumor flow ratio as measured by Tc-99m MAA imaging. CONCLUSION: Doses up to 99.5 Gy to uninvolved liver are tolerated with no clinical venoocclusive disease or liver failure. The lowest tumor dose producing a detectable response is 40.1 Gy. The utilization of MAA-based imaging techniques to determine tumor and liver blood flow for clinical treatment planning and the calculation of administered activity may improve clinical outcomes.


Asunto(s)
Neoplasias Hepáticas/terapia , Hígado/metabolismo , Hígado/patología , Microesferas , Itrio/efectos adversos , Adulto , Anciano , Anciano de 80 o más Años , Relación Dosis-Respuesta a Droga , Femenino , Humanos , Neoplasias Hepáticas/patología , Masculino , Persona de Mediana Edad , Metástasis de la Neoplasia , Receptores Toll-Like/metabolismo , Resultado del Tratamiento , Radioisótopos de Itrio
2.
Int Semin Surg Oncol ; 4: 17, 2007 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-17623095

RESUMEN

BACKGROUND: Accurate determination of the extrahepatic extent and intrahepatic distribution of disease is very important in patients with primary and metastatic liver disease for deciding whether a patient receives potentially curable surgery or palliative treatment. Our objective was to evaluate the efficacy of delayed phase FDG-PET/CT imaging in lesion detection and to define its clinical impact compared to triple-phase contrast enhanced CT (CECT). METHODS: 30 patients underwent delayed phase FDG-PET/CT imaging (90 min whole body scan followed by a delayed abdominal scan at 120 min). Maximum standard uptake values (SUVs) and SUV ratios between tumor and normal liver parenchyma (T/N) were evaluated. In addition, comparison was made to CECT obtained within 10 days of the FDG-PET/CT to evaluate for lesion concordance within individual liver segments (Couinaud designation). RESULTS: Sites of primary malignancies included: colorectal (19), breast (3), pancreas (2), lung (2), carcinoid (2), cholangiocarcinoma (1), and hepatocellular carcinoma (1). There was a significant increase in SUV value of liver lesions between early and delayed acquisition (P < 0.001). Although there was not a significant reduction in liver background activity between the two studies, there was a strong increase in T/N ratio (P < 0.001) allowing better lesion detection by visual inspection. New lesions were identified in 5 of the 30 patients, which were not appreciated on the early scan. Delayed phase FDG-PET/CT identified one lesion which was not present on the corresponding CECT. Delayed phase FDG-PET/CT revealed extrahepatic sites of metastases not appreciated on CECT in 6 patients. CONCLUSION: Delayed phase FDG-PET/CT protocol improved lesion detectability in primary and metastatic liver disease, revealing new lesions in 17% of the patients. Moreover, FDG-PET/CT identified extrahepatic disease not seen on CECT in 20% of the patients.

3.
Med Phys ; 33(7): 2479-90, 2006 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-16898451

RESUMEN

Scattered neutron dose equivalent to a representative point for a fetus is evaluated in an anthropomorphic phantom of the mother undergoing proton radiotherapy. The effect on scattered neutron dose equivalent to the fetus of changing the incident proton beam energy, aperture size, beam location, and air gap between the beam delivery snout and skin was studied for both a small field snout and a large field snout. Measurements of the fetus scattered neutron dose equivalent were made by placing a neutron bubble detector 10 cm below the umbilicus of an anthropomorphic Rando phantom enhanced by a wax bolus to simulate a second trimester pregnancy. The neutron dose equivalent in milliSieverts (mSv) per proton treatment Gray increased with incident proton energy and decreased with aperture size, distance of the fetus representative point from the field edge, and increasing air gap. Neutron dose equivalent to the fetus varied from 0.025 to 0.450 mSv per proton Gray for the small field snout and from 0.097 to 0.871 mSv per proton Gray for the large field snout. There is likely to be no excess risk to the fetus of severe mental retardation for a typical proton treatment of 80 Gray to the mother since the scattered neutron dose to the fetus of 69.7 mSv is well below the lower confidence limit for the threshold of 300 mGy observed for the occurrence of severe mental retardation in prenatally exposed Japanese atomic bomb survivors. However, based on the linear no threshold hypothesis, and this same typical treatment for the mother, the excess risk to the fetus of radiation induced cancer death in the first 10 years of life is 17.4 per 10,000 children.


Asunto(s)
Neutrones , Protones , Radioterapia de Alta Energía/métodos , Femenino , Humanos , Lactante , Recién Nacido , Discapacidad Intelectual/etiología , Exposición Materna , Neoplasias Inducidas por Radiación/etiología , Fantasmas de Imagen , Embarazo , Segundo Trimestre del Embarazo , Protección Radiológica , Radiometría
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA