Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 73
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Magn Reson Med ; 92(1): 43-56, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38303151

RESUMEN

PURPOSE: To introduce universal modes by applying the universal pulse concept to time-interleaved acquisition of modes (TIAMO), thereby achieving calibration-free B 1 + $$ {B}_1^{+} $$ inhomogeneity mitigation for body imaging at ultra-high fields. METHODS: Two databases of different RF arrays were used to demonstrate the feasibility of universal modes. The first comprised 31 cardiac in vivo data sets acquired at 7T while the second consisted of 6 simulated 10.5T pelvic data sets. Subject-specific solutions and universal modes were computed and subsequently evaluated alongside predefined default modes. For the cardiac database, subdivision into subpopulations was investigated. The optimization was performed using least-squares (LS) TIAMO and acquisition modes optimized for refocused echoes (AMORE). Finally, universal modes based on simulated pelvis data were applied in vivo at 10.5T. RESULTS: In all studied cases, the universal modes yield improvements over the predefined default modes of up to 51% (cardiac) and 30% (pelvic) in terms of median excitation error when using two modes. The subpopulation-specific cardiac solutions revealed a further improvement of universal modes at the expense of increased errors when applied outside the appropriate subpopulation. Direct application of simulation-based universal modes in vivo resulted in up to a 14% reduction in excitation error compared to default modes and up to a 34% reduction in peak 10 g local specific absorption rate (SAR) compared to subject-specific solutions. CONCLUSIONS: Universal modes are feasible for calibration-free B 1 + $$ {B}_1^{+} $$ inhomogeneity mitigation at ultra-high fields. In addition, simulation-based solutions can be applied directly in vivo, eliminating the need for large in vivo databases.


Asunto(s)
Algoritmos , Corazón , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Pelvis , Humanos , Corazón/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Pelvis/diagnóstico por imagen , Calibración , Masculino , Adulto , Simulación por Computador , Fantasmas de Imagen , Femenino , Análisis de los Mínimos Cuadrados , Bases de Datos Factuales
2.
Magn Reson Med ; 91(2): 513-529, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37705412

RESUMEN

PURPOSE: To increase the RF coil performance and RF management for body imaging at 10.5 T by validating and evaluating a high-density 16-channel transceiver array, implementing virtual observation points (VOPs), and demonstrating specific absorption rate (SAR) constrained imaging in vivo. METHODS: The inaccuracy of the electromagnetic model of the array was quantified based on B1 + and SAR data. Inter-subject variability was estimated using a new approach based on the relative SAR deviation of different RF shims between human body models. The pTx performance of the 16-channel array was assessed in simulation by comparison to a previously demonstrated 10-channel array. In vivo imaging of the prostate was performed demonstrating SAR-constrained static RF shimming and acquisition modes optimized for refocused echoes (AMORE). RESULTS: The model inaccuracy of 29% and the inter-subject variability of 85% resulted in a total safety factor of 1.91 for pelvis studies. For renal and cardiac imaging, inter-subject variabilities of 121% and 141% lead to total safety factors of 2.25 and 2.45, respectively. The shorter wavelength at 10.5 T supported the increased element density of the 16-channel array which in turn outperformed the 10-channel version for all investigated metrics. Peak 10 g local SAR reduction of more than 25% without a loss of image quality was achieved in vivo, allowing a theoretical improvement in measurement efficiency of up to 66%. CONCLUSIONS: By validating and characterizing a 16-channel dipole transceiver array, this work demonstrates, for the first time, a VOP-enabled RF coil for human torso imaging enabling increased pTx performance at 10.5 T.


Asunto(s)
Imagen por Resonancia Magnética , Próstata , Masculino , Humanos , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Diseño de Equipo , Simulación por Computador , Ondas de Radio
3.
Magn Reson Med ; 91(3): 1099-1114, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37997011

RESUMEN

PURPOSE: To evaluate the influence of skeletal maturation on sodium (23 Na) MRI relaxation parameters and the accuracy of tissue sodium concentration (TSC) quantification in human knee cartilage. METHODS: Twelve pediatric knee specimens were imaged with whole-body 10.5 T MRI using a density-adapted 3D radial projection sequence to evaluate 23 Na parameters: B1 + , T1 , biexponential T 2 * $$ {\mathrm{T}}_2^{\ast } $$ , and TSC. Water, collagen, and sulfated glycosaminoglycan (sGAG) content were calculated from osteochondral biopsies. The TSC was corrected for B1 + , relaxation, and water content. The literature-based TSC (TSCLB ) used previously published values for corrections, whereas the specimen-specific TSC (TSCSP ) used measurements from individual specimens. 23 Na parameters were evaluated in eight cartilage compartments segmented on proton images. Associations between 23 Na parameters, TSCLB - TSCSP difference, biochemical content, and age were determined. RESULTS: From birth to 12 years, cartilage water content decreased by 18%; collagen increased by 59%; and sGAG decreased by 36% (all R2 ≥ 0.557). The short T 2 * $$ {\mathrm{T}}_2^{\ast } $$ ( T 2 * S $$ {{\mathrm{T}}_2^{\ast}}_{\mathrm{S}} $$ ) decreased by 72%, and the signal fraction relaxing with T 2 * S $$ {{\mathrm{T}}_2^{\ast}}_{\mathrm{S}} $$ ( fT 2 * S $$ {{\mathrm{fT}}_2^{\ast}}_{\mathrm{S}} $$ ) increased by 55% during the first 5 years but remained relatively stable after that. TSCSP was significantly correlated with sGAG content from biopsies (R2 = 0.739). Depending on age, TSCLB showed higher or lower values than TSCSP . The TSCLB - TSCSP difference was significantly correlated with T 2 * S $$ {{\mathrm{T}}_2^{\ast}}_{\mathrm{S}} $$ (R2 = 0.850), fT 2 * S $$ {{\mathrm{fT}}_2^{\ast}}_{\mathrm{S}} $$ (R2 = 0.651), and water content (R2 = 0.738). CONCLUSION: TSC and relaxation parameters measured with 23 Na MRI provide noninvasive information about changes in sGAG content and collagen matrix during cartilage maturation. Cartilage TSC quantification assuming fixed relaxation may be feasible in children older than 5 years.


Asunto(s)
Cartílago Articular , Cartílago , Humanos , Niño , Preescolar , Imagen por Resonancia Magnética/métodos , Sodio , Colágeno , Agua , Cartílago Articular/diagnóstico por imagen
4.
Magn Reson Med ; 2024 Oct 16.
Artículo en Inglés | MEDLINE | ID: mdl-39415477

RESUMEN

PURPOSE: Toward pushing the boundaries of ultrahigh fields for human brain imaging, we wish to evaluate experimentally achievable SNR relative to ultimate intrinsic SNR (uiSNR) at 10.5T, develop design strategies toward approaching the latter, quantify magnetic field-dependent SNR gains, and demonstrate the feasibility of whole-brain, high-resolution human brain imaging at this uniquely high field strength. METHODS: A dual row 16-channel self-decoupled transmit (Tx) and receive (Rx) array was developed for 10.5T using custom Tx/Rx switches. A 64-channel receive-only array was built to fit into the 16-channel Tx/Rx array. Electromagnetic modeling and experiments were used to define safe operational power limits. Experimental SNR was evaluated relative to uiSNR at 10.5T and 7T. RESULTS: The 64-channel Rx array alone captured approximately 50% of the central uiSNR at 10.5T, while an identical array developed for 7T captured about 76% of uiSNR at 7T. The 16-channel Tx/80-channel Rx configuration brought the fraction of uiSNR captured at 10.5T to levels comparable to the 64-channel Rx array at 7T. SNR data displayed an approximate B 0 2 $$ {\mathrm{B}}_0^2 $$ dependence over a large central region when evaluated in the context of uiSNR. Whole-brain, high-resolution T 2 * $$ {\mathrm{T}}_2^{\ast } $$ -weighted and T1-weighted anatomical and gradient-recalled-echo BOLD-EPI functional MRI images were obtained at 10.5T for the first time with such an advanced array. CONCLUSION: We demonstrated the ability to approach the uiSNR at 10.5T over the human brain, achieving large SNR gains over 7T, currently the most commonly used ultrahigh-field platform. Whole-brain, high-resolution anatomical and EPI-based functional MRI data were obtained at 10.5T, illustrating the promise of greater than 10T fields in studying the human brain.

5.
NMR Biomed ; : e5228, 2024 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-39169274

RESUMEN

Quantitative maps of rotating frame relaxation (RFR) time constants are sensitive and useful magnetic resonance imaging tools with which to evaluate tissue integrity in vivo. However, to date, only moderate image resolutions of 1.6 x 1.6 x 3.6 mm3 have been used for whole-brain coverage RFR mapping in humans at 3 T. For more precise morphometrical examinations, higher spatial resolutions are desirable. Towards achieving the long-term goal of increasing the spatial resolution of RFR mapping without increasing scan times, we explore the use of the recently introduced Transform domain NOise Reduction with DIstribution Corrected principal component analysis (T-NORDIC) algorithm for thermal noise reduction. RFR acquisitions at 3 T were obtained from eight healthy participants (seven males and one female) aged 52 ± 20 years, including adiabatic T1ρ, T2ρ, and nonadiabatic Relaxation Along a Fictitious Field (RAFF) in the rotating frame of rank n = 4 (RAFF4) with both 1.6 x 1.6 x 3.6 mm3 and 1.25 x 1.25 x 2 mm3 image resolutions. We compared RFR values and their confidence intervals (CIs) obtained from fitting the denoised versus nondenoised images, at both voxel and regional levels separately for each resolution and RFR metric. The comparison of metrics obtained from denoised versus nondenoised images was performed with a two-sample paired t-test and statistical significance was set at p less than 0.05 after Bonferroni correction for multiple comparisons. The use of T-NORDIC on the RFR images prior to the fitting procedure decreases the uncertainty of parameter estimation (lower CIs) at both spatial resolutions. The effect was particularly prominent at high-spatial resolution for RAFF4. Moreover, T-NORDIC did not degrade map quality, and it had minimal impact on the RFR values. Denoising RFR images with T-NORDIC improves parameter estimation while preserving the image quality and accuracy of all RFR maps, ultimately enabling high-resolution RFR mapping in scan times that are suitable for clinical settings.

6.
MAGMA ; 37(4): 721-735, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39042205

RESUMEN

OBJECTIVE: Quantitative parameter mapping conventionally relies on curve fitting techniques to estimate parameters from magnetic resonance image series. This study compares conventional curve fitting techniques to methods using neural networks (NN) for measuring T2 in the prostate. MATERIALS AND METHODS: Large physics-based synthetic datasets simulating T2 mapping acquisitions were generated for training NNs and for quantitative performance comparisons. Four combinations of different NN architectures and training corpora were implemented and compared with four different curve fitting strategies. All methods were compared quantitatively using synthetic data with known ground truth, and further compared on in vivo test data, with and without noise augmentation, to evaluate feasibility and noise robustness. RESULTS: In the evaluation on synthetic data, a convolutional neural network (CNN), trained in a supervised fashion using synthetic data generated from naturalistic images, showed the highest overall accuracy and precision amongst the methods. On in vivo data, this best performing method produced low-noise T2 maps and showed the least deterioration with increasing input noise levels. DISCUSSION: This study showed that a CNN, trained with synthetic data in a supervised manner, may provide superior T2 estimation performance compared to conventional curve fitting, especially in low signal-to-noise regions.


Asunto(s)
Algoritmos , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Redes Neurales de la Computación , Próstata , Relación Señal-Ruido , Humanos , Masculino , Próstata/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Reproducibilidad de los Resultados
7.
NMR Biomed ; 36(5): e4874, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36368912

RESUMEN

The purpose of this work is to propose a tier-based formalism for safety assessment of custom-built radio-frequency (RF) coils that balances validation effort with the effort put in determinating the safety factor. The formalism has three tier levels. Higher tiers require increased effort when validating electromagnetic simulation results but allow for less conservative safety factors. In addition, we propose a new method to calculate modeling uncertainty between simulations and measurements and a new method to propagate uncertainties in the simulation into a safety factor that minimizes the risk of underestimating the peak specific absorption rate (SAR). The new safety assessment procedure was completed for all tier levels for an eight-channel dipole array for prostate imaging at 7 T and an eight-channel dipole array for head imaging at 10.5 T, using data from two different research sites. For the 7 T body array, the validation procedure resulted in a modeling uncertainty of 77% between measured and simulated local SAR distributions. For a situation where RF shimming is performed on the prostate, average power limits of 2.4 and 4.5 W/channel were found for tiers 2 and 3, respectively. When the worst-case peak SAR among all phase settings was calculated, power limits of 1.4 and 2.7 W/channel were found for tiers 2 and 3, respectively. For the 10.5 T head array, a modeling uncertainty of 21% was found based on B1 + mapping. For the tier 2 validation, a power limit of 2.6 W/channel was calculated. The demonstrated tier system provides a strategy for evaluating modeling inaccuracy, allowing for the rapid translation of novel coil designs with conservative safety factors and the implementation of less conservative safety factors for frequently used coil arrays at the expense of increased validation effort.


Asunto(s)
Imagen por Resonancia Magnética , Ondas de Radio , Masculino , Humanos , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Simulación por Computador , Próstata/diagnóstico por imagen
8.
Biometrics ; 79(2): 604-615, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-34806765

RESUMEN

Spatial partitioning methods correct for nonstationarity in spatially related data by partitioning the space into regions of local stationarity. Existing spatial partitioning methods can only estimate linear partitioning boundaries. This is inadequate for detecting an arbitrarily shaped anomalous spatial region within a larger area. We propose a novel Bayesian functional spatial partitioning (BFSP) algorithm, which estimates closed curves that act as partitioning boundaries around anomalous regions of data with a distinct distribution or spatial process. Our method utilizes transitions between a fixed Cartesian and moving polar coordinate system to model the smooth boundary curves using functional estimation tools. Using adaptive Metropolis-Hastings, the BFSP algorithm simultaneously estimates the partitioning boundary and the parameters of the spatial distributions within each region. Through simulation we show that our method is robust to shape of the target zone and region-specific spatial processes. We illustrate our method through the detection of prostate cancer lesions using magnetic resonance imaging.


Asunto(s)
Neoplasias de la Próstata , Masculino , Humanos , Teorema de Bayes , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Imagen por Resonancia Magnética , Algoritmos , Simulación por Computador
9.
AJR Am J Roentgenol ; 221(6): 788-804, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37377363

RESUMEN

The first commercially available 7-T MRI scanner (Magnetom Terra) was approved by the FDA in 2017 for clinical imaging of the brain and knee. After initial protocol development and sequence optimization efforts in volunteers, the 7-T system, in combination with an FDA-approved 1-channel transmit/32-channel receive array head coil, can now be routinely used for clinical brain MRI examinations. The ultrahigh field strength of 7-T MRI has the advantages of improved spatial resolution, increased SNR, and increased CNR but also introduces an array of new technical challenges. The purpose of this article is to describe an institutional experience with the use of the commercially available 7-T MRI scanner for routine clinical brain imaging. Specific clinical indications for which 7-T MRI may be useful for brain imaging include brain tumor evaluation with possible perfusion imaging and/or spectroscopy, radiotherapy planning; evaluation of multiple sclerosis and other demyelinating diseases, evaluation of Parkinson disease and guidance of deep brain stimulator placement, high-detail intracranial MRA and vessel wall imaging, evaluation of pituitary pathology, and evaluation of epilepsy. Detailed protocols, including sequence parameters, for these various indications are presented, and implementation challenges (including artifacts, safety, and side effects) and potential solutions are explored.


Asunto(s)
Neoplasias Encefálicas , Epilepsia , Humanos , Imagen por Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagen , Neuroimagen/métodos , Neoplasias Encefálicas/diagnóstico por imagen
10.
Magn Reson Med ; 88(4): 1702-1719, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35692053

RESUMEN

PURPOSE: To develop and evaluate a novel RF shimming optimization strategy tailored to improve the transmit efficiency in turbo spin echo imaging when performing time-interleaved acquisition of modes (TIAMO) at ultrahigh fields. THEORY AND METHODS: A nonlocalized efficiency shimming cost function is proposed and extended to perform TIAMO using acquisition modes optimized for refocused echoes (AMORE). The nonlocalized efficiency shimming was demonstrated in brain and knee imaging at 7 Tesla. Phantom and in vivo torso imaging studies were performed to compare the performance between AMORE and previously proposed TIAMO mode optimizations with and without localized constraints in turbo spin echo and gradient echo acquisitions. RESULTS: The proposed nonlocalized efficiency RF shimming produced a circularly polarized-like field with fewer signal dropouts in the brain and knee. For larger targets, AMORE was used and required a significantly lower transmitter voltage to produce a similar contrast to existing TIAMO mode design approaches for turbo spin echo as well as gradient echo acquisitions. In vivo, AMORE effectively reduced signal dropout in the interior torso while providing more uniform contrast with reduced transmit power. A local constraint further improved performance for a target region while maintaining performance in the larger FOV. CONCLUSION: AMORE based on the presented nonlocalized efficiency shimming cost function demonstrated improved contrast and SNR uniformity as well as increased transmit efficiency for both gradient echo and turbo spin echo acquisitions.


Asunto(s)
Interpretación de Imagen Asistida por Computador , Imagen por Resonancia Magnética , Algoritmos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen
11.
Magn Reson Med ; 88(6): 2645-2661, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35906923

RESUMEN

PURPOSE: To present electromagnetic simulation setups for detailed analyses of respiration's impact on B 1 + $$ {B}_1^{+} $$ and E-fields, local specific absorption rate (SAR) and associated safety-limits for 7T cardiac imaging. METHODS: Finite-difference time-domain electromagnetic field simulations were performed at five respiratory states using a breathing body model and a 16-element 7T body transceiver RF-coil array. B 1 + $$ {B}_1^{+} $$ and SAR are analyzed for fixed and moving coil configurations. SAR variations are investigated using phase/amplitude shimming considering (i) a local SAR-controlled mode (here SAR calculations consider RF amplitudes and phases) and (ii) a channel-wise power-controlled mode (SAR boundary calculation is independent of the channels' phases, only dependent on the channels' maximum amplitude). RESULTS: Respiration-induced variations of both B 1 + $$ {B}_1^{+} $$ amplitude and phase are observed. The flip angle homogeneity depends on the respiratory state used for B 1 + $$ {B}_1^{+} $$ shimming; best results were achieved for shimming on inhale and exhale simultaneously ( | Δ C V | < 35 % $$ \mid \Delta CV\mid <35\% $$ ). The results reflect that respiration impacts position and amplitude of the local SAR maximum. With the local-SAR-control mode, a safety factor of up to 1.4 is needed to accommodate for respiratory variations while the power control mode appears respiration-robust when the coil moves with respiration (SAR peak decrease: 9% exhale→inhale). Instead, a spatially fixed coil setup yields higher SAR variations with respiration. CONCLUSION: Respiratory motion does not only affect the B 1 + $$ {B}_1^{+} $$ distribution and hence the image contrast, but also location and magnitude of the peak spatial SAR. Therefore, respiration effects may need to be included in safety analyses of RF coils applied to the human thorax.


Asunto(s)
Campos Electromagnéticos , Imagen por Resonancia Magnética , Simulación por Computador , Humanos , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Ondas de Radio
12.
Magn Reson Med ; 87(4): 2074-2088, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34825735

RESUMEN

PURPOSE: The purpose of this study is to introduce a new antenna element with improved transmit performance, named the nonuniform dielectric substrate (NODES) antenna, for building transmit arrays at ultrahigh-field. METHODS: We optimized a dipole antenna at 10.5 Tesla by maximizing the B1+ -SAR efficiency in a phantom for a human spine target. The optimization parameters included permittivity variation in the substrate, substrate thickness, antenna length, and conductor geometry. We conducted electromagnetic simulations as well as phantom experiments to compare the transmit/receive performance of the proposed NODES antenna design with existing coil elements from the literature. RESULTS: Single NODES element showed up to 18% and 30% higher B1+ -SAR efficiency than the fractionated dipole and loop elements, respectively. The new element is substantially shorter than a commonly used dipole, which enables z-stacked array formation; it is additionally capable of providing a relatively uniform current distribution along its conductors. The nine-channel transmit/receive NODES array achieved 7.5% higher B1+ homogeneity than a loop array with the same number of elements. Excitation with the NODES array resulted in 33% lower peak 10g-averaged SAR and required 34% lower input power than the loop array for the target anatomy of the spine. CONCLUSION: In this study, we introduced a new RF coil element: the NODES antenna. NODES antenna outperformed the widely used loop and dipole elements and may provide improved transmit/receive performance for future ultrahigh field MRI applications.


Asunto(s)
Imagen por Resonancia Magnética , Ondas de Radio , Diseño de Equipo , Humanos , Fantasmas de Imagen , Columna Vertebral/diagnóstico por imagen
13.
Stat Med ; 41(3): 483-499, 2022 02 10.
Artículo en Inglés | MEDLINE | ID: mdl-34747059

RESUMEN

Multi-parametric magnetic resonance imaging (mpMRI) has been playing an increasingly important role in the detection of prostate cancer (PCa). Various computer-aided detection algorithms were proposed for automated PCa detection by combining information in multiple mpMRI parameters. However, there are specific features of mpMRI, including between-voxel correlation within each prostate and heterogeneity across patients, that have not been fully explored but could potentially improve PCa detection if leveraged appropriately. This article proposes novel Bayesian approaches for voxel-wise PCa classification that accounts for spatial correlation and between-patient heterogeneity in the mpMRI data. Modeling the spatial correlation is challenging due to the extreme high dimensionality of the data, and we propose three scalable approaches based on Nearest Neighbor Gaussian Process (NNGP), reduced-rank approximation, and a conditional autoregressive (CAR) model that approximates a Gaussian Process with the Matérn covariance, respectively. Our simulation study shows that properly modeling the spatial correlation and between-patient heterogeneity can substantially improve PCa classification. Application to in vivo data illustrates that classification is improved by all three spatial modeling approaches considered, while modeling the between-patient heterogeneity does not further improve our classifiers. Among the proposed models, the NNGP-based model is recommended given its high classification accuracy and computational efficiency.


Asunto(s)
Próstata , Neoplasias de la Próstata , Algoritmos , Teorema de Bayes , Humanos , Imagen por Resonancia Magnética , Masculino , Próstata/patología , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología
14.
MAGMA ; 35(4): 631-644, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35579785

RESUMEN

Multiparametric MRI of the prostate at clinical magnetic field strengths (1.5/3 Tesla) has emerged as a reliable noninvasive imaging modality for identifying clinically significant cancer, enabling selective sampling of high-risk regions with MRI-targeted biopsies, and enabling minimally invasive focal treatment options. With increased sensitivity and spectral resolution, ultra-high-field (UHF) MRI (≥ 7 Tesla) holds the promise of imaging and spectroscopy of the prostate with unprecedented detail. However, exploiting the advantages of ultra-high magnetic field is challenging due to inhomogeneity of the radiofrequency field and high local specific absorption rates, raising local heating in the body as a safety concern. In this work, we review various coil designs and acquisition strategies to overcome these challenges and demonstrate the potential of UHF MRI in anatomical, functional and metabolic imaging of the prostate and pelvic lymph nodes. When difficulties with power deposition of many refocusing pulses are overcome and the full potential of metabolic spectroscopic imaging is used, UHF MR(S)I may aid in a better understanding of the development and progression of local prostate cancer. Together with large field-of-view and low-flip-angle anatomical 3D imaging, 7 T MRI can be used in its full strength to characterize different tumor stages and help explain the onset and spatial distribution of metastatic spread.


Asunto(s)
Imagen por Resonancia Magnética , Neoplasias de la Próstata , Estudios de Factibilidad , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Próstata/metabolismo , Neoplasias de la Próstata/metabolismo , Ondas de Radio
15.
Magn Reson Med ; 86(1): 17-32, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33497006

RESUMEN

PURPOSE: To develop a 3D composite adiabatic spectral-spatial pulse for refocusing in spin-echo spectroscopy acquisitions and to compare its performance against standard acquisition methods. METHODS: A 3D composite adiabatic pulse was designed by modulating a train of parallel transmit-optimized 2D subpulses with an adiabatic envelope. The spatial and spectral profiles were simulated and validated by experiments to demonstrate the feasibility of the design in both single and double spin-echo spectroscopy acquisitions. Phantom and in vivo studies were performed to evaluate the pulse performance and compared with semi-LASER with respect to localization performance, sequence timing, signal suppression, and specific absorption rate. RESULTS: Simultaneous 2D spatial localization with water and lipid suppression was achieved with the designed refocusing pulse, allowing high-quality spectra to be acquired with shorter minimum TE/TR, reduced SAR, as well as adaptation to spatially varying B0 and B1+ field inhomogeneities in both prostate and brain studies. CONCLUSION: The proposed composite pulse can serve as a more SAR efficient alternative to conventional localization methods such as semi-LASER at ultrahigh field for spin echo-based spectroscopy studies. Subpulse parallel-transmit optimization provides the flexibility to manage the tradeoff among multiple design criteria to accommodate different field strengths and applications.


Asunto(s)
Algoritmos , Encéfalo , Encéfalo/diagnóstico por imagen , Espectroscopía de Resonancia Magnética , Masculino , Fantasmas de Imagen , Próstata
16.
Magn Reson Med ; 86(3): 1544-1559, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33821502

RESUMEN

PURPOSE: The primary goal of this study was to investigate whether chronic exposures to ultra-high B0 fields can induce long-term cognitive, behavioral, or biological changes in C57BL/6 mice. METHODS: C57BL/6 mice were chronically exposed to 10.5-T or 16.4-T magnetic fields (3-h exposures, two exposure sessions per week, 4 or 8 weeks of exposure). In vivo single-voxel 1 H magnetic resonance spectroscopy was used to investigate possible neurochemical changes in the hippocampus. In addition, a battery of behavioral tests, including the Morris water-maze, balance-beam, rotarod, and fear-conditioning tests, were used to examine long-term changes induced by B0 exposures. RESULTS: Hippocampal neurochemical profile, cognitive, and basic motor functions were not impaired by chronic magnetic field exposures. However, the balance-beam-walking test and the Morris water-maze testing revealed B0 -induced changes in motor coordination and balance. The tight-circling locomotor behavior during Morris water-maze tests was found as the most sensitive factor indexing B0 -induced changes. Long-term behavioral changes were observed days or even weeks subsequent to the last B0 exposure at 16.4 T but not at 10.5 T. Fast motion of mice in and out of the 16.4-T magnet was not sufficient to induce such changes. CONCLUSION: Observed results suggest that the chronic exposure to a magnetic field as high as 16.4 T may result in long-term impairment of the vestibular system in mice. Although observation of mice may not directly translate to humans, nevertheless, they indicate that studies focused on human safety at very high magnetic fields are necessary.


Asunto(s)
Condicionamiento Psicológico , Actividad Motora , Animales , Conducta Animal , Campos Magnéticos , Ratones , Ratones Endogámicos C57BL
17.
AJR Am J Roentgenol ; 217(4): 919-920, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-33852359

RESUMEN

This study compared prostate multiparametric MRI (mpMRI) performed using an 18-French rectal tube in place throughout the examination after initial placement by a technologist (n = 97) with mpMRI performed without rectal tube placement (n = 99). Acquisition parameters were otherwise identical. Two radiologists scored subjective image quality and measured rectal diameter. For both readers, rectal tube placement was associated (p < .001) with improved ADC map quality, decreased DWI distortion, decreased rectal gas, and decreased rectal diameter. Findings support routine rectal tube placement for prostate mpMRI.


Asunto(s)
Aumento de la Imagen , Imágenes de Resonancia Magnética Multiparamétrica/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Anciano , Artefactos , Flatulencia/prevención & control , Humanos , Masculino , Persona de Mediana Edad , Imágenes de Resonancia Magnética Multiparamétrica/instrumentación , Recto
18.
Magn Reson Med ; 84(1): 289-303, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-31846121

RESUMEN

PURPOSE: To investigate the feasibility of imaging the human torso and to evaluate the performance of several radiofrequency (RF) management strategies at 10.5T. METHODS: Healthy volunteers were imaged on a 10.5T whole-body scanner in multiple target anatomies, including the prostate, hip, kidney, liver, and heart. Phase-only shimming and spoke pulses were used to demonstrate their performance in managing the B1+ inhomogeneity present at 447 MHz. Imaging protocols included both qualitative and quantitative acquisitions to show the feasibility of imaging with different contrasts. RESULTS: High-quality images were acquired and demonstrated excellent overall contrast and signal-to-noise ratio. The experimental results matched well with predictions and suggested good translational capabilities of the RF management strategies previously developed at 7T. Phase-only shimming provided increased efficiency, but showed pronounced limitations in homogeneity, demonstrating the need for the increased degrees of freedom made possible through single- and multispoke RF pulse design. CONCLUSION: The first in-vivo human imaging was successfully performed at 10.5T using previously developed RF management strategies. Further improvement in RF coils, transmit chain, and full integration of parallel transmit functionality are needed to fully realize the benefits of 10.5T.


Asunto(s)
Interpretación de Imagen Asistida por Computador , Imagen por Resonancia Magnética , Corazón , Humanos , Masculino , Ondas de Radio , Relación Señal-Ruido
19.
Magn Reson Med ; 84(1): 484-496, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-31751499

RESUMEN

PURPOSE: The purpose of this study is to safely acquire the first human head images at 10.5T. METHODS: To ensure safety of subjects, we validated the electromagnetic simulation model of our coil. We obtained quantitative agreement between simulated and experimental B1+ and specific absorption rate (SAR). Using the validated coil model, we calculated radiofrequency power levels to safely image human subjects. We conducted all experiments and imaging sessions in a controlled radiofrequency safety lab and the whole-body 10.5T scanner in the Center for Magnetic Resonance Research. RESULTS: Quantitative agreement between the simulated and experimental results was obtained including S-parameters, B1+ maps, and SAR. We calculated peak 10 g average SAR using 4 different realistic human body models for a quadrature excitation and demonstrated that the peak 10 g SAR variation between subjects was less than 30%. We calculated safe power limits based on this set and used those limits to acquire T2 - and T2∗ -weighted images of human subjects at 10.5T. CONCLUSIONS: In this study, we acquired the first in vivo human head images at 10.5T using an 8-channel transmit/receive coil. We implemented and expanded a previously proposed workflow to validate the electromagnetic simulation model of the 8-channel transmit/receive coil. Using the validated coil model, we calculated radiofrequency power levels to safely image human subjects.


Asunto(s)
Imagen por Resonancia Magnética , Ondas de Radio , Simulación por Computador , Humanos , Fantasmas de Imagen
20.
Magn Reson Med ; 84(6): 3485-3493, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32767392

RESUMEN

PURPOSE: In this study, we investigate a strategy to reduce the local specific absorption rate (SAR) while keeping B1+ constant inside the region of interest (ROI) at the ultra-high field (B0 ≥ 7T) MRI. METHODS: Locally raising the resonance structure under the discontinuity (i.e., creating a bump) increases the distance between the accumulated charges and the tissue. As a result, it reduces the electric field and local SAR generated by these charges inside the tissue. The B1+ at a point that is sufficiently far from the coil, however, is not affected by this modification. In this study, three different resonant elements (i.e., loop coil, snake antenna, and fractionated dipole [FD]) are investigated. For experimental validation, a bumped FD is further investigated at 10.5T. After the validation, the transmit performances of eight-channel arrays of each element are compared through electromagnetic (EM) simulations. RESULTS: Introducing a bump reduced the peak 10g-averaged SAR by 21, 26, 23% for the loop and snake antenna at 7T, and FD at 10.5T, respectively. In addition, eight-channel bumped FD array at 10.5T had a 27% lower peak 10g-averaged SAR in a realistic human body simulation (i.e., prostate imaging) compared to an eight-channel FD array. CONCLUSION: In this study, we investigated a simple design strategy based on adding bumps to a resonant element to reduce the local SAR while maintaining B1+ inside an ROI. As an example, we modified an FD and performed EM simulations and phantom experiments with a 10.5T scanner. Results show that the peak 10g-averaged SAR can be reduced more than 25%.


Asunto(s)
Imagen por Resonancia Magnética , Ondas de Radio , Diseño de Equipo , Humanos , Masculino , Fantasmas de Imagen , Próstata
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA