1.
Clin Chem Lab Med ; 60(4): 469-478, 2022 03 28.
Artículo en Inglés | MEDLINE | ID: mdl-32970605

RESUMEN

OBJECTIVES: Kidney markers are some of the most frequently used laboratory tests in patient care, and correct clinical decision making depends upon knowledge and correct application of biological variation (BV) data. The aim of this study was to review available BV data and to provide updated BV estimates for the following kidney markers in serum and plasma; albumin, creatinine, cystatin C, chloride, potassium, sodium and urea. CONTENT: Relevant studies were identified from a historical BV database as well as by systematic literature searches. Retrieved publications were appraised by the Biological Variation Data Critical Appraisal Checklist (BIVAC). Meta-analyses of BIVAC compliant studies with similar design were performed to deliver global estimates of within-subject (CVI) and between-subject (CVG) BV estimates. Out of the 61 identified papers, three received a BIVAC grade A, four grade B, 48 grade C, five grade D grade and one was not appraised as it did not report numerical BV estimates. Most studies were identified for creatinine (n=48). BV estimates derived from the meta-analysis were in general lower than previously reported estimates for all analytes except urea. For some measurands, BV estimates may be influenced by age or states of health, but further data are required. SUMMARY: This review provides updated global BV estimates for kidney related measurands. For all measurands except for urea, these estimates were lower than previously reported. OUTLOOK: For the measurands analyzed in this review, there are sufficient well-designed studies available to publish a trustworthy estimate of BV. However, for a number of newly appearing kidney markers no suitable data is available and additional studies are required.


Asunto(s)
Riñón , Urea , Biomarcadores , Creatinina , Humanos
2.
Clin Chem Lab Med ; 58(1): 25-32, 2019 Dec 18.
Artículo en Inglés | MEDLINE | ID: mdl-31503541

RESUMEN

Background Interpretation of the complete blood count (CBC) parameters requires reliable biological variation (BV) data. The aims of this study were to appraise the quality of publications reporting BV data for CBC parameters by applying the BV Data Critical Appraisal Checklist (BIVAC) and to deliver global BV estimates based on BIVAC compliant studies. Methods Relevant publications were identified by a systematic literature search and evaluated for their compliance with the 14 BIVAC criteria, scored as A, B, C or D, indicating decreasing compliance. Global CVI and CVG estimates with 95% CI were delivered by a meta-analysis approach using data from BIVAC compliant papers (grades A-C). Results In total, 32 studies were identified; four received a BIVAC grade A, 2 B, 20 C and 6 D. Meta-analysis derived CVI and CVG estimates were generally lower or in line with those published in a historical BV database available online. Except for reticulocytes, CVI estimates of erythrocyte related parameters were below 3%, whereas platelet (except MPV and PDW) and leukocyte related parameters ranged from 5% to 15%. Conclusions A systematic review of CBC parameters has provided updated, global estimates of CVI and CVG that will be included in the newly published European Federation of Clinical Chemistry and Laboratory Medicine BV Database.


Asunto(s)
Pruebas Hematológicas/estadística & datos numéricos , Humanos
3.
Clin Chem ; 64(3): 501-514, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29222339

RESUMEN

BACKGROUND: Concern has been raised about the quality of available biological variation (BV) estimates and the effect of their application in clinical practice. A European Federation of Clinical Chemistry and Laboratory Medicine Task and Finish Group has addressed this issue. The aim of this report is to (a) describe the Biological Variation Data Critical Appraisal Checklist (BIVAC), which verifies whether publications have included all essential elements that may impact the veracity of associated BV estimates, (b) use the BIVAC to critically appraise existing BV publications on enzymes, lipids, kidney, and diabetes-related measurands, and (c) apply metaanalysis to deliver a global within-subject BV (CVI) estimate for alanine aminotransferase (ALT). METHODS: In the BIVAC, publications were rated as A, B, C, or D, indicating descending compliance for 14 BIVAC quality items, focusing on study design, methodology, and statistical handling. A D grade indicated that associated BV estimates should not be applied in clinical practice. Systematic searches were applied to identify BV studies for 28 different measurands. RESULTS: In total, 128 publications were identified, providing 935 different BV estimates. Nine percent achieved D scores. Outlier analysis and variance homogeneity testing were scored as C in >60% of 847 cases. Metaanalysis delivered a CVI estimate for ALT of 15.4%. CONCLUSIONS: Application of BIVAC to BV publications identified deficiencies in required study detail and delivery, especially for statistical analysis. Those deficiencies impact the veracity of BV estimates. BV data from BIVAC-compliant studies can be combined to deliver robust global estimates for safe clinical application.


Asunto(s)
Alanina Transaminasa/sangre , Química Clínica/normas , Lista de Verificación , Química Clínica/métodos , Humanos , Valores de Referencia
4.
Clin Chem Lab Med ; 56(3): 403-412, 2018 02 23.
Artículo en Inglés | MEDLINE | ID: mdl-29055937

RESUMEN

BACKGROUND: There is no consensus in the literature about what analytes or values should be informed as critical results and how they should be communicated. The main aim of this project is to establish consensual standards of critical results for the laboratories participating in the study. Among the project's secondary objectives, establishing consensual procedures for communication can be highlighted. METHODS: Consensus was reached among all participating laboratories establishing the basis for the construction of the initial model put forward for consensus in conjunction with the clinicians. A real-time Delphi, methodology "health consensus" (HC), with motivating and participative questions was applied. The physician was expected to choose a numeric value within a scale designed for each analyte. RESULTS: The medians of critical results obtained represent the consensus on critical results for outpatient and inpatient care. Both in primary care and in hospital care a high degree of consensus was observed for critical values proposed in the analysis of creatinine, digoxin, phosphorus, glucose, international normalized ratio (INR), leukocytes, magnesium, neutrophils, chloride, sodium, calcium and lithium. For the rest of critical results the degree of consensus obtained was "medium high". The results obtained showed that in 72% of cases the consensual critical value coincided with the medians initially proposed by the laboratories. CONCLUSIONS: The real-time Delphi has allowed obtaining consensual standards for communication of critical results among the laboratories participating in the study, which can serve as a basis for other organizations.


Asunto(s)
Técnicas de Laboratorio Clínico , Técnica Delphi , Inteligencia , Consenso , Humanos , Relación Normalizada Internacional
5.
Clin Chem Lab Med ; 53(6): 863-70, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25928757

RESUMEN

The aims of this study are: 1) to use the data included in the biological variation (BV) database to address the usability of BV estimates; and 2) to use different examples from the authors' laboratories to illustrate the use and the usefulness of BV data in laboratory medicine. The BV database is an essential tool for laboratory management. Examples of application of data derived from BV are given in this paper, such as analytical performance specifications that have been included in various quality control software designed to optimize operative rules; also they have been incorporated as acceptability limits in external quality assurance reports. BV data from pathological status are of utmost interest for monitoring patients and differences between the intra-individual coefficients of variation (CVI) estimated from healthy and patients are shown. However, for a number of analytes there are limited data available and for many there are no data, consequently new studies should be encouraged at an international level. In addition, developing international criteria to evaluate publications dealing with the estimation of BV components would be of the utmost interest. We are ready and willing to collaborate with such worthy initiatives. The first EFLM strategic conference on analytical performance specifications is an excellent opportunity for debating these ideas.


Asunto(s)
Bioensayo/normas , Análisis de Varianza , Creatinina/sangre , Bases de Datos Factuales , Humanos , Variaciones Dependientes del Observador , Control de Calidad , Valores de Referencia
6.
Clin Chem Lab Med ; 53(2): 299-305, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25415636

RESUMEN

BACKGROUND: Numerical data on the components of biological variation (BV) have many uses in laboratory medicine, including in the setting of analytical quality specifications, generation of reference change values and assessment of the utility of conventional reference values. METHODS: Generation of a series of up-to-date comprehensive database of components of BV was initiated in 1997, integrating the more relevant information found in publications concerning BV. A scoring system was designed to evaluate the robustness of the data included. The database has been updated every 2 years, made available on the Internet and derived analytical quality specifications for imprecision, bias and total allowable error included in the tabulation of data. RESULTS AND CONCLUSIONS: Our aim here is to document, in detail, the methodology we used to evaluate the reliability of the included data compiled from the published literature. To date, our approach has not been explicitly documented, although the principles have been presented at many symposia, courses and conferences.


Asunto(s)
Calcio/sangre , Bases de Datos Factuales , Humanos , Internet , Valores de Referencia
7.
Clin Chem Lab Med ; 52(11): 1557-68, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24897397

RESUMEN

BACKGROUND: Hemolysis is the main cause of non-quality samples in clinical laboratories, producing the highest percentage of rejections in the external assurance programs of preanalytical quality. The objective was to: 1) study the agreement between the detection methods and quantification of hemolysis; 2) establish comparable hemolysis interference limits for a series of tests and analytical methods; and 3) study the preanalytical variables which most influence hemolysis production. METHODS: Different hemoglobin concentration standards were prepared using the reference method. Agreement was studied between automated methods [hemolytic indexes (HI)] and reference method, as well as the interference according to hemolysis degree in various biochemical tests was measured. Preanalytical variables which could influence hemolysis production were studied: type of extraction, type of tubes, transport time, temperature and centrifugation conditions. RESULTS: Good agreement was obtained between hemoglobin concentrations measured using the reference method and HI, for the most of studied analyzers, particularly those giving quantitative HI. The hemolysis interference cut-off points obtained for the majority of tests studied (except LDH, K) are dependent on the method/analyzer utilized. Furthermore, discrepancies have been observed between interference limits recommended by the manufacturer. The preanalytical variables which produce a lower percentage of hemolysis rejections were: centrifugation at the extraction site, the use of lower volume tubes and a transport time under 15 min at room temperature. CONCLUSIONS: The setting of interference limits (cut-off) for each used test/method, and the study of preanalytical variability will assist to the results harmonization for this quality indicator.


Asunto(s)
Pruebas Hematológicas/métodos , Hemoglobinas/análisis , Laboratorios/normas , Automatización , Pruebas Hematológicas/instrumentación , Hemólisis , Humanos , Oportunidad Relativa
8.
Clin Chem Lab Med ; 49(3): 463-70, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21275807

RESUMEN

BACKGROUND: The results of 5 years of experience (2004-2008) with process-based quality management using quality indicators for key laboratory processes (analytic and extra-analytic) in a group of clinical laboratories affiliated with the Catalan Health Institute are presented. Our purpose was to analyze the evolution of the indicators, identify processes that require corrective measures, and obtain specifications that are more robust than the preliminary ones proposed in a previous study by the same group. METHODS: The yearly average was recorded for each indicator in each laboratory, the yearly interlaboratory median was calculated, and the changes occurring were studied to determine their continuity in the 5-year period. For each indicator, the average of the yearly medians was calculated and the results transformed to the Six Sigma scale to estimate the degree of control over the related process. It was suggested to establish the yearly interlaboratory median as the desirable specification for each indicator. RESULTS: The medians for most indicators were stable during the period studied. Thus, the specifications proposed in the first study were considered robust in these cases. The Six Sigma statistic provided added value in this study because it enabled detection of processes that should be improved, in which case the specifications proposed were considered provisional despite their stability. After identifying processes that have the greatest impact on patient safety, the group set a specification of 0%, regardless of the actual specification obtained, although the members are conscious of the difficulty in attaining this level of quality. Certain processes that are in a period of change obtained specifications that are considered in a phase of consolidation. CONCLUSIONS: The results for indicators related with sample collection indicate that the process is stable and well controlled. However, based on the results for Hemolyzed serum sample, the group saw the need for installing centrifuges in all phlebotomy centers and established a recommendation to unify the system for measuring hemolysis. The indicator External control exceeds acceptance limit clearly highlighted the need to rigorously monitor the analytic phase of the clinical laboratory. The values obtained for the indicator Reports from referred tests exceed delivery time show that there is considerable deviation regarding the expected report delivery time, whereas for in-house laboratory reports, delivery time is satisfactory.


Asunto(s)
Técnicas de Laboratorio Clínico/normas , Indicadores de Calidad de la Atención de Salud , Control de Calidad
9.
Clin Chem Lab Med ; 48(7): 1015-9, 2010 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-20491599

RESUMEN

BACKGROUND: Quality specifications for indicators of the key analytic processes have been defined by international consensus. However, only preliminary specifications for laboratory-related strategic and support processes have been developed. The present study attempts to increase the robustness of the preliminary proposed specifications. METHODS: Recovering records and incidences occurred over a 4-year follow-up period, for 12 indicators, used in all laboratories from this group regarding strategic and support processes. RESULTS AND CONCLUSIONS: The results obtained indicate that it is better to establish an interval rather than a fixed value for the majority of indicators. Longer studies are needed to properly assess some quality specifications, and data recording system must be standardized in others. Additional, multicenter studies are needed to establish more robust specifications and determine the state of the art of laboratories in other settings.


Asunto(s)
Técnicas de Laboratorio Clínico/normas , Indicadores de Calidad de la Atención de Salud , Humanos , Satisfacción del Paciente
10.
Adv Lab Med ; 1(3): 20200029, 2020 Oct.
Artículo en Inglés, Español | MEDLINE | ID: mdl-37361503

RESUMEN

Objectives: Numerous biological variation (BV) studies have been performed over the years, but the quality of these studies vary. The objectives of this study were to perform a systematic review and critical appraisal of BV studies on glycosylated albumin and to deliver updated BV estimates for glucose and HbA1c, including recently published high-quality studies such as the European Biological Variation study (EuBIVAS). Methods: Systematic literature searches were performed to identify BV studies. Nine publications not included in a previous review were identified; four for glycosylated albumin, three for glucose, and three for HbA1c. Relevant studies were appraised by the Biological Variation Data Critical Appraisal Checklist (BIVAC). Global BV estimates were derived by meta-analysis of BIVAC-compliant studies in healthy subjects with similar study design. Results: One study received BIVAC grade A, 2B, and 6C. In most cases, the C-grade was associated with deficiencies in statistical analysis. BV estimates for glycosylated albumin were: CVI=1.4% (1.2-2.1) and CVG=5.7% (4.7-10.6), whereas estimates for HbA1c, CVI=1.2% (0.3-2.5), CVG=5.4% (3.3-7.3), and glucose, CVI=5.0% (4.1-12.0), CVG=8.1% (2.7-10.8) did not differ from previously published global estimates. Conclusions: The critical appraisal and rating of BV studies according to their methodological quality, followed by a meta-analysis, generate robust, and reliable BV estimates. This study delivers updated and evidence-based BV estimates for glycosylated albumin, glucose and HbA1c.

11.
Adv Lab Med ; 1(2): 20200019, 2020 Jun.
Artículo en Inglés, Español | MEDLINE | ID: mdl-37363776

RESUMEN

The purpose of this study is to understand the evolution of the analytical performance of the laboratories participating in the Spanish society of laboratory medicine (SEQCML) external quality assurance (EQA) programmes during its 30 years of operation and to compare it with the performance of other EQA programmes to establish whether the results are similar. The results obtained during this period are evaluated by applying the biological variability (BV) and state of the art-derived quality specifications. In addition, the results are compared with those obtained by other EQA programme organisations. It is noted that the laboratories participating in the EQA-SEQCML programmes have improved their performance over 30 years of experience and that the specifications derived from biological variation are achievable. It is difficult to compare EQA programmes, due to lack of accessibility and the differences in the design of these programmes (control materials, calculations used and analytical specifications established). The data from this study show that for some biological magnitudes the results obtained by the programmes are not yet harmonised, although efforts are being made to achieve this. Organisers of EQA programmes should also join the harmonisation effort by providing information on their results to enable comparison.

12.
Adv Lab Med ; 1(1): 20200008, 2020 Mar.
Artículo en Inglés, Español | MEDLINE | ID: mdl-37362553

RESUMEN

Background: The objective of the present study was to examine the evolution of the analytical performance specifications (APS) used in External Quality Assurance (EQA) schemes, as well as the efficacy of a category 1 EQA scheme in monitoring the harmonization of clinical laboratory results in Spain. Methods: A review of the literature on the types of quality specifications used in schemes in other countries and their evolution was performed. In addition, a comparative analysis of the potential impact that different APS from eight countries had on clinical decision-making was made based on three measurands: sodium, thyroid-stimulating hormone (TSH), and activated partial thromboplastin time (aPTT). Results: Harmonization of analytical methods was demonstrated by assessing whether average results deviated from the certified reference value of control materials within the APS derived from biological variation (BV). The APS used in EQA have evolved from state-of-the-art models to BV. Poor clinical decision-making would occur if the results accepted by some APS were applied. Conclusions: In Spain, only 2 of the 18 measurands studied are considered to be well harmonized. Closer collaboration between laboratories and analytical system providers would be required to resolve discrepancies.

13.
Biochem Med (Zagreb) ; 29(1): 010701, 2019 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-30591811

RESUMEN

INTRODUCTION: Standardization is the ability to obtain interchangeable results leading to same medical interpretation. External quality assessment (EQA) is the main support of the on-going harmonization initiatives. Aim of study was to evaluate results obtained from two years category 1 EQA program experience in Spain and determine the impact of applying this type of EQA program on the analytical standardization. MATERIALS AND METHODS: According to the analytical method, traceability and instrument different groups were established which results were evaluated by calculating mean, coefficient of variation and percent of deviation to the reference value. Analytical performance specifications used to the results' evaluation were derived from biological variation for bias and from the inter-laboratory coefficients of variation found in a previous pilot study. RESULTS: Only creatinine measured by enzymatic methods gave excellent results, although few laboratories used this method. Creatine kinase and GGT gave good precision and bias in all, but one instrument studied. For the remaining analytes (ALT, ALP, AST, bilirubin, calcium, chloride, glucose, magnesium, potassium, sodium, total protein and urate) some improvement is still necessary to achieve satisfactory standardization in our setting. CONCLUSIONS: The two years of category 1 EQA program experience in Spain have manifested a lack of standardization of 17 most frequent biochemistry tests used in our laboratories. The impact of the information obtained on the lack of standardization is to recommend abandoning methods such as ALT, AST without exogenous pyridoxal phosphate, Jaffe method for creatinine, and do not use non-commutable calibrators, such as aqueous solutions for calcium and sodium.


Asunto(s)
Técnicas de Laboratorio Clínico/normas , Creatina Quinasa/sangre , Creatinina/sangre , gamma-Glutamiltransferasa/sangre , Humanos , Garantía de la Calidad de Atención de Salud , España
14.
Clin Chim Acta ; 495: 467-475, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31103621

RESUMEN

BACKGROUND: Biological variation (BV) data can be used to set analytical performance specifications (APS) for lipid assays. Poor performance will impact upon the efficacy of international guidelines for cardiovascular risk assessment (CVR) and relevant clinical decision limits. This systematic review applies the Biological Variation Data Critical Appraisal Checklist (BIVAC) to published studies of BV of CVR biomarkers enabling metanalysis of the data. METHODS: Studies of BV of total cholesterol, HDL-cholesterol, LDL-cholesterol, triglycerides and apolipoproteins A1 and B, retrieved using a systematic literature search, were evaluated and graded using the BIVAC. Meta-analysis of CVI and CVG estimates were performed utilizing weightings based upon BIVAC grades and the width of the data confidence intervals. RESULTS: Applying the BIVAC, ten publications were graded as D, 43 as C, 5 as B and 1 as A (fully compliant). A total of 196 CVI and 87 CVG estimates were available for the different lipid measurands. The meta-analysis-derived BV data estimates were generally concordant with those in the online 2014 BV database. CONCLUSIONS: Application of BIVAC identifies BV data suitable for many important applications including setting APS. Additionally, this review identifies a need for new BIVAC compliant studies to deliver BV reference data in different subpopulations.


Asunto(s)
Enfermedades Cardiovasculares/sangre , Lípidos/sangre , Biomarcadores/sangre , Enfermedades Cardiovasculares/epidemiología , Lista de Verificación , Humanos , Medición de Riesgo
15.
Ann Transl Med ; 5(6): 133, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28462213

RESUMEN

BACKGROUND: The Commission of Analytical Quality and the Committee of External Quality Programs of Spanish Society of Laboratory Medicine (SEQC) in collaboration with the Dutch Foundation for the Quality organized the first national category 1 External Quality Assessment Programs (EQAP) pilot study. The aim is to evaluate the standardization of serum creatinine measurements in the Spanish laboratories through a category 1 external quality assurance program with commutable material and reference method assigned values. METHODS: A total of 87 Spanish laboratories were involved in this program in 2015. Each day a sample control was measured by duplicate during 6 consecutive days. Percentage deviations and coefficients of variation obtained were compared with quality specifications derived from biological variation. RESULTS: A total of 1044 creatinine results were obtained. Laboratories were coded in 11 different method-traceability combinations. Only enzymatic methods get all results within the acceptability limits. DISCUSSION: To participate in a category 1 EQAP is a valuable tool to assess the standardization degree in our country; a big effort should be made to promote laboratories to change their procedures and to use enzymatic creatinine methods, in order to achieve a satisfactory standardization degree for this important analyte.

16.
Clin Lab Med ; 37(1): 47-56, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28153369

RESUMEN

Biological variation gives valuable information about how the living organism regulates its constituents within and between subjects; this information on the behavior of body components allows us to derive consequences concerning reference populations and intervals. With a more pragmatic approach biological variation has three uses: setting the appropriate analytical performance specification for each analyte to limit the amount of error that laboratory could introduce in its measurements, to help distinguish health from disease, and to implement internal quality control with the automatic verification of results.


Asunto(s)
Líquidos Corporales/química , Técnicas de Laboratorio Clínico/métodos , Laboratorios/normas , Líquidos Corporales/fisiología , Errores Diagnósticos , Humanos , Control de Calidad , Valores de Referencia
17.
Clin Chim Acta ; 346(1): 13-8, 2004 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-15234631

RESUMEN

BACKGROUND: [corrected] Data on within- and between-subject biological variation are available for around 250 analytes commonly used in medical laboratories. METHODS: Integration of this data into the quality system occurs at all three levels of laboratory activity: (a) Preanalytic process: biological variation provides the basis for selecting the most appropriate specimen for analysis, for defining sample stability and for deciding suitable timing between samplings; (b) analytic process: biological variation-derived goals are fundamental for designing internal quality control procedures, and for evaluating laboratory performance; and (c) postanalytic process: delta checks based on within-subject biological variation values are used for validating results and for interpreting serial results from a patient. CONCLUSION: The biological variation is a pillar for managing quality in laboratory medicine.


Asunto(s)
Sistemas de Información en Laboratorio Clínico/normas , Técnicas de Laboratorio Clínico/normas , Recolección de Datos/normas , Análisis Químico de la Sangre , Humanos , Laboratorios de Hospital , Ciencia del Laboratorio Clínico , Control de Calidad , Reproducibilidad de los Resultados , Manejo de Especímenes , Análisis de Sistemas
18.
Rev. lab. clín ; 9(4): 147-158, oct.-dic. 2016. tab
Artículo en Inglés | IBECS (España) | ID: ibc-158431

RESUMEN

Introduction. The selection and definition of quality indicators is essential for proper control of processes. This is not always easy, particularly with extra-analytical indicators, due to the complexity and degree of comparison of processes between laboratories, and the fact that data collection is not always automated. For this reason, the indicators and specifications need to be dynamic and re-designed in accordance with changes in the system. The aim of this paper is to describe the methodology used in the selection and definition of quality indicators, and their specifications for extra-analytical processes in public laboratories in Catalonia. Material and methods. During the study period (2004-2013), the members of the working group reported the mean annual value for each indicator, and the overall yearly mean of all participants was calculated. These results were compared and analyzed during periodic meetings, with regards to the pre-established specifications of the different laboratories. Results. Quality indicators and their specifications are presented. The evaluation of the validity of each quality indicator was made taking into account aspects including usefulness of the indicator in process monitoring, a clear definition, and a precise and reliable quantification. This methodology has made it possible to contrast the validity of the indicators or to reconsider the specification. Conclusions. The last 10 years’ experience of the Catalonian Health Institute Working Group on Quality Indicators in designing indicators and establishing quality specifications has proved very useful for improving the monitoring of processes in clinical laboratories included in the group (AU)


Introducción. La selección y definición de los indicadores de la calidad es imprescindible para controlar adecuadamente un proceso. Ello no siempre es fácil, sobre todo en el caso de los indicadores extraanalíticos, dada la complejidad y grado de comparabilidad de los procesos entre laboratorios y la necesaria recogida de datos que en muchas ocasiones no está automatizada. Asimismo, los indicadores y especificaciones deben ser dinámicos y rediseñarse en función de los cambios del sistema. El objetivo de este trabajo es describir la metodología utilizada en la selección y definición de indicadores de calidad y especificaciones para los procesos extraanalíticos en los laboratorios públicos de Cataluña. Material y métodos. Durante el período de estudio (2004-2013), los miembros del grupo han informado del valor medio anual para cada indicador, y se ha calculado la media anual de todos los participantes para cada uno de ellos. Estos resultados se han comparado y analizado a través de reuniones periódicas, con respecto a las especificaciones preestablecidas de los diferentes laboratorios. Resultados. Se presentan los indicadores de calidad y sus especificaciones. La evaluación de la validez de cada indicador de calidad se llevó a cabo teniendo en cuenta los aspectos incluyendo la utilidad del indicador en la supervisión de procesos, una definición clara y una cuantificación precisa y fiable. Esta metodología ha permitido contrastar la validez de los indicadores o reconsiderar la especificación. Conclusiones. Los últimos 10 años de experiencia del Grupo de Trabajo del Instituto Catalán de la Salud de Indicadores de Calidad en el diseño de indicadores y en establecer especificaciones de calidad ha demostrado ser muy útil para mejorar el seguimiento de los procesos en los laboratorios clínicos integrados en el grupo (AU)


Asunto(s)
Humanos , Masculino , Femenino , Ciencia del Laboratorio Clínico/métodos , Técnicas de Laboratorio Clínico/métodos , Prueba de Laboratorio/métodos , Indicadores de Calidad de la Atención de Salud/organización & administración , Indicadores de Calidad de la Atención de Salud/normas , Indicadores de Calidad de la Atención de Salud , Garantía de la Calidad de Atención de Salud/organización & administración , Garantía de la Calidad de Atención de Salud/normas , Control de Calidad , Calidad de la Atención de Salud/organización & administración , Calidad de la Atención de Salud/normas
19.
Clin Chem Lab Med ; 46(8): 1189-94, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18605959

RESUMEN

BACKGROUND: This work is the second part of a study regarding indicators and quality specifications for the non-analytical processes in laboratory medicine. Five primary care and five hospital laboratories agreed on the indicators for two strategic processes (quality planning and project development) and various support processes (client relationships, instrument and infrastructure maintenance, safety and risk prevention, purchases and storage, personnel training). METHODS: In the majority of cases, the median values recorded over 1 year is considered to be the state-of-the-art in our setting and proposed as the quality specification for the indicators stated. Values have been stratified according to primary care and hospital laboratory for referred tests and group of personnel for training. In some cases, the specifications have been set equal to zero events, such as serious incidents in the infrastructure maintenance process and number of work accidents in the safety and risk prevention process. RESULTS AND CONCLUSIONS: In light of this study, an effort is needed to optimize decisions regarding corrective actions and to move from a subjective individual criterion to systematic and comparative management. This preliminary study provides a comprehensive vision of a subject that could motivate further research and advances in the quality of laboratory services.


Asunto(s)
Química Clínica/normas , Laboratorios , Indicadores de Calidad de la Atención de Salud , Humanos , Mantenimiento , Satisfacción del Paciente , Administración de Personal , Gestión de Riesgos
20.
Rev. lab. clín ; 3(4): 192-200, oct.-dic. 2010. tab, ilus
Artículo en Español | IBECS (España) | ID: ibc-85214

RESUMEN

Los autores realizan una revisión exhaustiva sobre la variación biológica, con el objeto de resaltar su aplicación práctica en la rutina diaria del laboratorio clínico. Se describe brevemente el método de estimación de los componentes de la variación biológica y se detalla la base de datos actualizada bianualmente y disponible para los profesionales del sector. Se pormenoriza el uso práctico en el control interno del proceso analítico, en la evaluación de los datos del control interno y externo, así como en la detección de errores analíticos y extraanalíticos. Finalmente, se explica con claridad cómo notificar la posibilidad de un cambio significativo en el estado de salud del paciente en el informe analítico (AU)


This is an exhaustive review on biological variation, which aims to highlight its practical application in daily routine of clinical laboratories. The methodology to estimate the components of biological variation is summarised and a database, which is updated every two years and available to professionals of the area, is explained in detail. Daily application of data derived from biological variation in daily practice in internal and external quality control, as well as, in the detection of analytical and non-analytical errors is clearly explained. Last, but not least, examples are given on how to notify to clinicians on possible changes in patients health status (AU)


Asunto(s)
Humanos , Masculino , Femenino , Valores de Referencia , Técnicas de Laboratorio Clínico/normas , Técnicas de Laboratorio Clínico/tendencias , Técnicas de Laboratorio Clínico , Biomarcadores/análisis , Equipo de Laboratorio , Sistemas de Información en Laboratorio Clínico/ética , Sistemas de Información en Laboratorio Clínico/organización & administración , Sistemas de Información en Laboratorio Clínico/normas , Tecnología Biomédica/ética , Tecnología Biomédica/métodos , Tecnología Biomédica/normas , Personal de Laboratorio/ética , Personal de Laboratorio/organización & administración