Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 75
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
BMC Musculoskelet Disord ; 25(1): 352, 2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38702633

RESUMEN

BACKGROUND: Recent advancements in and the proliferation of autonomous mobility technology, such as intelligent wheelchairs, have made it possible to provide mobility services for patients with reduced mobility due to musculoskeletal disorders. In the present study, we conducted a preliminary clinical study to assess the safety and feasibility of in-hospital autonomous transportation using a driverless mobility (wheelchair) for patients with musculoskeletal disorders. METHODS: From January to February 2022, 51 patients with musculoskeletal disorders exhibiting gait disturbance who presented to our institution were included in the present study. Driverless mobility rides were conducted over a straight-line distance of 100 m from the orthopaedic outpatient reception to the payment counter after the outpatient consultation. We assessed the quality of life using an EQ-5D-5 L index and pain using a VAS score before riding the mobility to investigate the patient's condition. After the ride, a questionnaire survey was conducted to assess patient satisfaction on a 5-point scale. In addition, adverse events during the mobility ride were investigated. RESULTS: Overall satisfaction levels showed that 44 out of 51 (86%) patients rated the level as 3 or higher. There were no significant differences in the level of satisfaction based on the cause of disorders or EQ-5D-5 L Index. Among 19 patients who rated the level of satisfaction as 2-3, the ratio of postoperative patients and those with pain tended to be higher (p < 0.05). While 26 of 51 (51%) patients reported moments of feeling unsafe during the mobility ride, no actual adverse events, such as collisions, were observed. CONCLUSIONS: An in-hospital autonomous transportation service using a driverless mobility for patients with musculoskeletal disorders demonstrated high satisfaction levels and was safe with no severe adverse events observed. The expansion of autonomous mobility deployment is expected to achieve mobility as a service in medical care.


Asunto(s)
Estudios de Factibilidad , Enfermedades Musculoesqueléticas , Satisfacción del Paciente , Humanos , Masculino , Enfermedades Musculoesqueléticas/terapia , Enfermedades Musculoesqueléticas/fisiopatología , Enfermedades Musculoesqueléticas/diagnóstico , Femenino , Persona de Mediana Edad , Adulto , Anciano , Calidad de Vida , Silla de Ruedas , Transporte de Pacientes/métodos , Limitación de la Movilidad , Encuestas y Cuestionarios , Anciano de 80 o más Años
2.
Eur J Orthop Surg Traumatol ; 33(2): 441-447, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35103855

RESUMEN

PURPOSE: This study evaluated the efficacy and safety of a novel treatment for osteonecrosis, in which concentrated autologous bone marrow aspirate transplantation (CABMAT) is followed by low-intensity pulsed ultrasound (LIPUS) stimulation for 3 months. The study was designed as a prospective, uncontrolled, open-label phase II clinical study. METHODS: This study included 16 cases of osteonecrosis of the femoral head (ONFH), including 26 hips. Patients were transplanted with concentrated bone marrow and periodically evaluated for infection and neoplasm development. Moreover, clinical and radiological examinations were conducted to confirm the treatment efficacy. RESULTS: No infections were observed during the course of this study nor tumours developed at the treatment site 24 months after transplantation. At a mean 48 (30-56) months post-transplantation, the onset or progression of collapse was noted in four hips, of which one hip underwent total hip arthroplasty. CONCLUSION: Treatment with CABMAT combined with 3-month LIPUS stimulation was safe, and further randomised clinical studies are needed to determine the efficacy and feasibility of this treatment. TRIAL REGISTRATION: UMIN Clinical Trials Registry (UMIN000020940, 9/2/2016).


Asunto(s)
Médula Ósea , Necrosis de la Cabeza Femoral , Humanos , Médula Ósea/patología , Trasplante de Médula Ósea , Cabeza Femoral/cirugía , Cabeza Femoral/patología , Necrosis de la Cabeza Femoral/cirugía , Necrosis de la Cabeza Femoral/patología , Estudios Prospectivos , Trasplante Autólogo , Resultado del Tratamiento
3.
BMC Musculoskelet Disord ; 20(1): 410, 2019 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-31488133

RESUMEN

BACKGROUND: Idiopathic osteonecrosis of the femoral head (ONFH) occurs at a relatively younger age. It is therefore important to prevent the resultant femoral head collapse and requirement of total hip arthroplasty in these patients. In 2003, we initiated concentrated autologous bone marrow aspirate transplantation (CABMAT), a joint-preserving treatment for ONFH, at our institution. Here, we report the long-term results of CABMAT treatment. METHODS: We retrospectively collated and analyzed the demographic and treatment data of 69 patients (109 hips) with idiopathic ONFH treated with CABMAT between April 2003 and April 2008. RESULTS: Totally, 44 patients (21 men, 23 women, 80 hips) completed the 10-year follow-up. The follow-up rate was 73.4%, and the mean follow-up period was 12.0 (range, 10.0-15.4) years. The mean age of the patients was 42.2 (range, 16.3-70.5) years. Using the Association Research Circulation Osseous (ARCO) classification system for preoperative analysis, 12, 31, 32, and 5 hips were classified as stages 1, 2, 3, and 4, respectively. The overall rate of conversion to total hip arthroplasty (THA) was 34% (27/80 hips). In a multivariate regression analysis, the preoperative stage of ONFH and the body mass index were found to correlate significantly with conversion to THA. Totally, 43 hips (of 80) were classified as belonging to the pre-collapse stage (i.e., stages 1 or 2). The overall collapse rate and the THA-conversion rate of these hips were estimated to be 49% (21/43) and 14% (6/43), respectively. CONCLUSIONS: On the basis of our long-term findings, the minimally invasive and feasible CABMAT therapy can be utilized as one of a joint-preserving treatment for ONFH.


Asunto(s)
Artroplastia de Reemplazo de Cadera/estadística & datos numéricos , Trasplante de Médula Ósea , Necrosis de la Cabeza Femoral/cirugía , Articulación de la Cadera/cirugía , Tratamientos Conservadores del Órgano , Adolescente , Adulto , Anciano , Índice de Masa Corporal , Femenino , Cabeza Femoral/patología , Cabeza Femoral/cirugía , Necrosis de la Cabeza Femoral/complicaciones , Necrosis de la Cabeza Femoral/patología , Estudios de Seguimiento , Articulación de la Cadera/patología , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Trasplante Autólogo , Resultado del Tratamiento , Adulto Joven
4.
Int Orthop ; 42(7): 1623-1630, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29705871

RESUMEN

PURPOSE: We had previously established concentrated autologous bone marrow aspirate transplantation (CABMAT), a one-step, low-invasive, joint-preserving surgical technique for treating osteonecrosis of the femoral head (ONFH). This study aimed to evaluate the effects of CABMAT as a hip-preserving surgical approach, preventing conversion to total hip arthroplasty (THA) and femoral head collapse in patients with systemic lupus erythematosus (SLE). METHODS: Since 2003, 52 SLE patients (8 male, 44 female, 92 hips, mean age 35.3 (16-77) (years) were treated with CABMAT. The mean follow-up period was 5.5 (0.7-14) years. Conversion rate to THA and its predicting factors were analyzed. RESULTS: The overall conversion rate to THA was 29% (27/92). Conversion rate to THA was 0% (0/3), 0% (0/4), 22% (9/41), and 41% (18/44) in types A, B, C1, and C2, respectively. Conversion rate to THA was 26% (5/19), 26% (6/23), 28% (11/39), 44% (4/9), and 50% (1/2) in stages 1, 2, 3A, 3B, and 4, respectively. In multivariate logistic regression analysis, sex, body mass index (BMI), pre-operative type, and pre-operative stage were significantly correlated with conversion to THA. CONCLUSION: The conversion rate to THA was lower than that in the natural course and core decompression, but was higher than that seen in other bone marrow transplantation and osteotomy. Since sex, pre-operative type, and pre-operative stage were significantly correlated with conversion to THA, it is suggested that the higher proportion of women, advanced stage (stage 3A or above), and advanced type (type C or above) in this study affected the THA conversion rate.


Asunto(s)
Trasplante de Médula Ósea/métodos , Necrosis de la Cabeza Femoral/terapia , Glucocorticoides/efectos adversos , Lupus Eritematoso Sistémico/complicaciones , Adolescente , Adulto , Anciano , Artroplastia de Reemplazo de Cadera/estadística & datos numéricos , Trasplante de Médula Ósea/efectos adversos , Conversión a Cirugía Abierta/estadística & datos numéricos , Femenino , Necrosis de la Cabeza Femoral/inducido químicamente , Glucocorticoides/uso terapéutico , Articulación de la Cadera/patología , Articulación de la Cadera/cirugía , Humanos , Lupus Eritematoso Sistémico/tratamiento farmacológico , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Trasplante Autólogo , Resultado del Tratamiento , Adulto Joven
5.
Biochem Biophys Res Commun ; 493(2): 1010-1017, 2017 11 18.
Artículo en Inglés | MEDLINE | ID: mdl-28942150

RESUMEN

Glucocorticoids cause the delayed wound healing by suppressing inflammation that is required for wound healing process. Adipose tissue-derived mesenchymal stem cells (AT-MSCs) play an important role for wound healing by their cytokine productions including stromal derived factor 1 (SDF-1). However, it has not been clear how glucocorticoids affect the wound healing ability of AT-MSCs. In this study, we found that glucocorticoid downregulated SDF-1 expression in AT-MSCs. In addition, glucocorticoid-treated AT-MSCs induced less migration of inflammatory cells and impaired wound healing capacity compared with glucocorticoid-untreated AT-MSCs. Of note, prostaglandin E2 (PGE2) synthesis-related gene expression was downregulated by glucocorticoid and PGE2 treatment rescued not only SDF-1 expression in the presence of glucocorticoid but also their wound healing capacity in vivo. Furthermore, we found SDF-1-overexpressed AT-MSCs restored wound healing capacity even after treatment of glucocorticoid. Consistent with the results obtained from glucocorticoid-treated AT-MSCs, we found that AT-MSCs isolated from steroidal osteonecrosis donors (sAT-MSCs) who received chronic glucocorticoid therapy showed less SDF-1 expression and impaired wound healing capacity compared with traumatic osteonecrosis donor-derived AT-MSCs (nAT-MSCs). Moreover, the SDF-1 level was also reduced in plasma derived from steroidal osteonecrosis donors compared with traumatic osteonecrosis donors. These results provide the evidence that concomitant application of AT-MSCs with glucocorticoid shows impaired biological modulatory effects that induce impaired wound healing.


Asunto(s)
Tejido Adiposo/citología , Quimiocina CXCL12/genética , Regulación hacia Abajo/efectos de los fármacos , Glucocorticoides/farmacología , Trasplante de Células Madre Mesenquimatosas , Células Madre Mesenquimatosas/efectos de los fármacos , Cicatrización de Heridas , Tejido Adiposo/efectos de los fármacos , Animales , Células Cultivadas , Quimiocina CXCL12/análisis , Humanos , Células Madre Mesenquimatosas/citología , Ratones Endogámicos C57BL , Cicatrización de Heridas/efectos de los fármacos
6.
J Bone Miner Metab ; 35(2): 209-214, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27026435

RESUMEN

The purpose of this study was to determine fracture location and the characteristics of patients with atypical femoral fractures (AFFs). We studied 38 AFFs in 34 patients admitted to our institution between November 2007 and July 2013. The diagnostic criteria for the AFFs were based on 2014 American Society of Bone and Mineral Research guidelines. We classified the fracture location as proximal, middle, or distal to trisect the femoral diaphysis from just distal to the lesser trochanter to just proximal to the supracondylar flare. Bowing was defined as a line through the inside of the tip of the great trochanter and a condylar center that was outside the medullary cavity. We investigated the fracture's location, existence of coronal bowing, and bisphosphonates (BPs), glucocorticoids (GCs), and proton pump inhibitors therapy. We analyzed associations between fracture location and demographic and clinical factors. Twelve fractures were proximal, 25 were middle, and one was distal. Nineteen limbs showed femoral bowing. Thirty-one patients received BP treatment-20 patients received alendronic acid, eight risedronic acid, and three minodronic acid. Fourteen patients received a GC, and 16 received a proton pump inhibitor. There was a significant association between coronal bowing and middle fracture locations, GC therapy and proximal fracture locations, and older age and middle fracture locations. Tall height and heavy weight had an association with proximal fracture location, and short height and light weight had an association with middle fracture location. In conclusion, we provide evidence supporting a causal relationship between BP-related severely suppressed bone turnover and AFFs. We also provide evidence supporting additional influences from altered distribution of mechanical stress with femoral bowing and various factors, such as GC therapy, age, body weight, and height, which might negatively affect bone intensity and quality and result in fracture.


Asunto(s)
Conservadores de la Densidad Ósea/efectos adversos , Difosfonatos/efectos adversos , Fracturas del Fémur/diagnóstico , Fémur/patología , Anciano , Anciano de 80 o más Años , Alendronato/efectos adversos , Alendronato/uso terapéutico , Pueblo Asiatico , Conservadores de la Densidad Ósea/uso terapéutico , Remodelación Ósea , Difosfonatos/uso terapéutico , Femenino , Fracturas del Fémur/patología , Glucocorticoides/efectos adversos , Glucocorticoides/uso terapéutico , Humanos , Imidazoles/efectos adversos , Imidazoles/uso terapéutico , Japón , Masculino , Persona de Mediana Edad , Inhibidores de la Bomba de Protones/efectos adversos , Inhibidores de la Bomba de Protones/uso terapéutico , Estudios Retrospectivos , Ácido Risedrónico/efectos adversos , Ácido Risedrónico/uso terapéutico
7.
BMC Musculoskelet Disord ; 18(1): 292, 2017 Jul 06.
Artículo en Inglés | MEDLINE | ID: mdl-28683795

RESUMEN

BACKGROUND: We had previously established concentrated autologous bone marrow aspirate transplantation (CABMAT), a one-step, low-invasive, joint-preserving surgical technique for treating osteonecrosis of the femoral head (ONFH). The present study aimed to evaluate the effects of CABMAT as a hip preserving surgical approach, preventing femoral head collapse in asymptomatic ONFH. METHODS: In total, 222 patients (341 hips) with ONFH were treated with CABMAT between April 2003 and March 2013. Based on magnetic resonance imaging, we determined that 119 of these patients had bilateral asymptomatic ONFH (238 hips), and 38 further patients had unilateral asymptomatic ONFH (38 hips). In this series, we retrospectively examined 31 hips in 31 patients with unilateral asymptomatic ONFH treated surgically between 2003 and 2012 and followed up for more than 2 years. Clinical and radiological evaluation were performed immediately before the procedure and at the final follow-up. The two-year follow-up rate among patients with unilateral ONFH was 82% (31/38). Therefore, the present study included 31 patients (19 males and 12 females), with a mean age and follow-up period of 40 and 5.8 years, respectively. Of the 31 asymptomatic hips, 5, 6, 10, and 10 had osteonecrosis of types A, B, C1, and C2, respectively. The diagnosis, classification, and staging of ONFH were based on the 2001 Japanese Orthopaedic Association (JOA) classification. RESULTS: Secondary collapse of the femoral head was observed in 6/10 hips and 5/10 hips with osteonecrosis of types C1 and C2, respectively. Total hip arthroplasty was performed in 9.6% of patients (3/31 hips), at an average of 33 months after surgery. Clinical symptoms improved after surgery, and the secondary collapse rate at a mean of 5.8 years after CABMAT was lower than that reported in several previous studies on the natural course of asymptomatic ONFH. CONCLUSIONS: Early diagnosis of ONFH (i.e., before femoral head collapse) and early intervention with CABMAT could improve the clinical outcome of corticosteroid and alcohol-induced ONFH.


Asunto(s)
Artroplastia de Reemplazo de Cadera/tendencias , Trasplante de Médula Ósea/tendencias , Necrosis de la Cabeza Femoral/diagnóstico por imagen , Necrosis de la Cabeza Femoral/terapia , Imagen por Resonancia Magnética/tendencias , Adulto , Anciano , Artroplastia de Reemplazo de Cadera/métodos , Trasplante de Médula Ósea/métodos , Femenino , Estudios de Seguimiento , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Tiempo , Trasplante Autólogo/métodos , Trasplante Autólogo/tendencias , Resultado del Tratamiento
8.
J Phys Ther Sci ; 29(6): 1102-1107, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28626336

RESUMEN

[Purpose] The convalescent rehabilitation ward (CRW) plays an important role for hip fracture patients in Japanese super-aged society. The purpose of this study is to clarify the usefulness of the CRW concomitant with acute wards in a single hospital. [Subjects and Methods] 110 hip fracture patients were evaluated; 63 patients were moved from acute wards to the CRW in the same hospital (Group C) and 47 patients were treated in acute wards only (Group A). Patient selection was determined by each attending doctor. The outcomes were examined from medical records. [Results] 90.5% of patients in the group C were discharged to home and 57.4% in the group A. 92.9% of patients in the group C had regained their ambulatory ability at discharge and 88.9% in the group A. The average total functional independence measure scores at discharge were 96.4 in the group C and 85.0 in the group A. The one-year mortality was 2.4% in the group C and 8.3% in the group A. [Conclusion] Using a CRW concomitant with acute wards in a single hospital could achieve a high home-discharge rate, good functional recovery, and low mortality in hip fracture patients.

9.
Cytotherapy ; 18(2): 198-204, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26794712

RESUMEN

BACKGROUND AIMS: Internalizing quantum dots (i-QDs) are a useful tool for tracking cells in vivo in models of tissue regeneration. We previously synthesized i-QDs by conjugating QDs with a unique internalizing antibody against a heat shock protein 70 family stress chaperone. In the present study, i-QDs were used to label rabbit mesenchymal stromal cells (MSCs) that were then transplanted into rabbits to assess differentiation potential in an osteonecrosis model. METHODS: The i-QDs were taken up by bone marrow-derived MSCs collected from the iliac of 12-week-old Japanese white rabbits that were positive for cluster of differentiation (CD)81 and negative for CD34 and human leukocyte antigen DR. The average rate of i-QD internalization was 93.3%. At 4, 8, 12, and 24 weeks after transplantation, tissue repair was evaluated histologically and by epifluorescence and electron microscopy. RESULTS: The i-QDs were detected at the margins of the drill holes and in the necrotized bone trabecular. There was significant colocalization of the i-QD signal in transplanted cells and markers of osteoblast and mineralization at 4, 8, and 12 weeks post-transplantation, while i-QDs were detected in areas of mineralization at 12 and 24 weeks post-transplantation. Moreover, i-QDs were observed in osteoblasts in regenerated tissue by electron microscopy, demonstrating that the tissue was derived from transplanted cells. CONCLUSION: These results indicate that transplanted MSCs can differentiate into osteoblasts and induce tissue repair in an osteonecrosis model and can be tracked over the long term by i-QD labeling.


Asunto(s)
Rastreo Celular/métodos , Trasplante de Células Madre Mesenquimatosas/métodos , Células Madre Mesenquimatosas/citología , Osteoblastos/citología , Osteonecrosis/terapia , Puntos Cuánticos/metabolismo , Animales , Antígenos CD34/metabolismo , Médula Ósea , Células de la Médula Ósea/citología , Huesos/citología , Diferenciación Celular/fisiología , Humanos , Conejos , Tetraspanina 28/metabolismo , Trasplante Autólogo
10.
J Orthop Sci ; 21(3): 342-7, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26970833

RESUMEN

BACKGROUND: The Harris-Galante total hip arthroplasty (THA) is a first-generation cementless THA with a porous coating for biological fixation of the implant. Many studies report excellent long-term results for the acetabular cup, but few long-term studies exist for the femoral stem because of relatively poor short-term and midterm results. Here we present the 21- to 27-year results of the cup and the stem of the Harris-Galante THA. METHODS: From 1985 to 1991, 102 Harris-Galante THAs were inserted in 82 patients. At the time of the THA, the mean patient age was 54 years (range, 20-78 years). The primary diagnosis was secondary osteoarthritis due to developmental hip dysplasia (69 [68%] hips). The Japanese Orthopaedic Association (JOA) hip score and thigh pain were measures of clinical outcome. Radiographic review was performed retrospectively. Implant survival was evaluated by Kaplan-Meier analysis. RESULTS: Of 102 hips, 35 hips were from 31 deceased patients, 5 patients (6 hips) were lost to follow-up, 12 hips were revised, and 49 hips were from patients living at the latest follow-up. Among the living patients, 36 hips had a clinical evaluation and 42 hips had a radiograph obtained more than 21 years. The JOA hip score improved from 42 points preoperatively to 83.5 points at the latest follow-up. Thigh pain was reported in 13 hips. One cup and four stems were loose at the latest radiographic review. Most cup revisions were related to acetabular osteolysis. Fifteen hips showed severe stress shielding. Kaplan-Meier analysis of survivorship with any revision, acetabular reoperation, stem revision, and stem loosening as the end point was 87.0%, 90.3%, 95.7% and 86.4%, respectively, at 24.6 years. CONCLUSIONS: Long-term implant survival and clinical results of the Harris-Galante THA were good. Acetabular osteolysis-related cup loosening was a problem of the cup. Loosening, thigh pain, and stress shielding were problems of the stem.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Articulación de la Cadera/fisiopatología , Articulación de la Cadera/cirugía , Prótesis de Cadera , Diseño de Prótesis , Falla de Prótesis , Adulto , Factores de Edad , Anciano , Artroplastia de Reemplazo de Cadera/efectos adversos , Cementos para Huesos , Distribución de Chi-Cuadrado , Estudios de Cohortes , Intervalos de Confianza , Bases de Datos Factuales , Estudios de Seguimiento , Articulación de la Cadera/diagnóstico por imagen , Humanos , Japón , Estimación de Kaplan-Meier , Persona de Mediana Edad , Radiografía/métodos , Estudios Retrospectivos , Medición de Riesgo , Factores Sexuales , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
11.
Eur J Orthop Surg Traumatol ; 26(3): 293-8, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26920362

RESUMEN

Osteonecrosis of the femoral head (ONFH) is commonly treated with total hip arthroplasty; however, the disadvantages of this form of treatment, especially in young patients, include the need for revision arthroplasty. Here we describe a novel, combined approach to the treatment of ONFH based on autologous concentrated bone marrow grafting and low-intensity pulsed ultrasound (LIPUS). The 7 male and 7 female patients (mean age: 40 years; 22 hips) underwent autologous concentrated bone marrow grafting followed by 6 months of continuous LIPUS. The mean follow-up period was 26 months. We evaluated site-specific bacterial infection of the grafted bone marrow concentrate microbiologically and site-specific cancer by magnetic resonance imaging 24 months after grafting. All patients were assessed using the visual analogue scale (VAS) for pain and the Japanese Orthopedic Association (JOA) hip score. Clinical and plain radiographic evaluations were performed before grafting and at the most recent follow-up. Computed tomography (CT) scans were obtained before and 12 months after grafting. None of the grafted bone marrow concentrates were infected, and none of the patients developed a tumor at the treatment site. The VAS and JOA scores improved in all patients. Collapse progressed in 8 of the 22 hips, but none required total hip arthroplasty. The mean volume of new bone formation 12 months post-grafting as seen on CT was 1256 mm(3). New bone formation was observed in all patients. Our study demonstrates the safety and efficacy of autologous concentrated bone marrow grafting and LIPUS as a joint-preserving procedure for patients with ONFH.


Asunto(s)
Trasplante de Médula Ósea , Necrosis de la Cabeza Femoral/terapia , Ondas Ultrasónicas , Adulto , Trasplante de Médula Ósea/efectos adversos , Trasplante de Médula Ósea/métodos , Terapia Combinada , Femenino , Cabeza Femoral/diagnóstico por imagen , Cabeza Femoral/patología , Necrosis de la Cabeza Femoral/diagnóstico por imagen , Necrosis de la Cabeza Femoral/patología , Humanos , Masculino , Persona de Mediana Edad , Ondas Ultrasónicas/efectos adversos , Adulto Joven
12.
Eur J Orthop Surg Traumatol ; 24(5): 671-8, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24275891

RESUMEN

The purpose of this study was to evaluate the clinical and radiographic treatment effects of percutaneous autologous concentrated bone marrow grafting in nonunion cases and to evaluate the effectiveness of this grafting procedure. We enrolled 17 cases those had atrophic changes due to continuous nonunion for over 9 months after injury and had undergone low-intensity pulsed ultrasound treatment for more than 3 months. The site of nonunion was the femur in 10 cases, the tibia in 5 cases, the humerus in 1 case, and the ulna in 1 case. They underwent percutaneous autologous concentrated bone marrow grafting and continued low-intensity pulsed ultrasound stimulation treatment after grafting. Patients were evaluated using the visual analogue scale for pain at immediately before the procedure, 3, 6, and 12 months after grafting. Plain radiographs of the affected site were taken and evaluated about the healing of the nonunion site at each clinical evaluation. As quantitative assessment, CT scans were undertaken before the procedure and 6 months after grafting. The visual analogue scale pain score was reduced consistently after grafting in all patients. About the healing at the nonunion site, 11 and 13 cases of bone union were observed at 6 and 12 months after grafting. The mean volume of callus formation based on CT images was 4,147 (262-27,392) mm3 total between grafting and 6 months. Percutaneous autologous concentrated bone marrow grafting is an effective procedure for the treatment of patients with nonunion.


Asunto(s)
Trasplante de Médula Ósea/métodos , Fracturas no Consolidadas/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Trasplante de Médula Ósea/rehabilitación , Terapia Combinada , Femenino , Fracturas del Fémur/diagnóstico por imagen , Fracturas del Fémur/rehabilitación , Fracturas del Fémur/cirugía , Fracturas no Consolidadas/diagnóstico por imagen , Fracturas no Consolidadas/rehabilitación , Humanos , Fracturas del Húmero/diagnóstico por imagen , Fracturas del Húmero/rehabilitación , Fracturas del Húmero/cirugía , Inyecciones Intralesiones , Masculino , Persona de Mediana Edad , Dimensión del Dolor , Dolor Postoperatorio/etiología , Cuidados Posoperatorios/métodos , Estudios Retrospectivos , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/rehabilitación , Fracturas de la Tibia/cirugía , Tomografía Computarizada por Rayos X , Trasplante Autólogo/métodos , Trasplante Autólogo/rehabilitación , Resultado del Tratamiento , Fracturas del Cúbito/diagnóstico por imagen , Fracturas del Cúbito/rehabilitación , Fracturas del Cúbito/cirugía , Terapia por Ultrasonido/métodos , Adulto Joven
13.
Int J Surg Case Rep ; 123: 110287, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39299197

RESUMEN

INTRODUCTION: In treating nonunion, the removal of a broken nail is often difficult. We report a technique for removing a broken Kuntscher intramedullary nail. In this technique, a chisel is inserted into the lumen of the intramedullary nail, and the nail is rotated. CASE PRESENTATION: A 57-year-old man presented to our hospital with femoral diaphyseal nonunion lasting 17 years after injury. The patient suffered a right femoral diaphyseal fracture at 40 years old and was treated with a Kuntscher intramedullary nail. The patient underwent two additional surgeries at another hospital for the nonunion; however, the nonunion did not heal, and the intramedullary nail broke. The patient was diagnosed with noninfectious hypertrophic nonunion and underwent surgery. We resected part of the lateral cortex of the femoral diaphyseal nonunion and reached the proximal end of the broken Kuntscher intramedullary nail. We inserted a chisel into the lumen of the intramedullary nail, held the chisel using pliers, and rotated the nail to separate it from the surrounding tissue. The proximal side of the broken intramedullary nail was easily removable. One year after surgery, the right femoral pseudarthrosis was healed with a bony callus. DISCUSSION: This procedure was possible because of the structural characteristics of the intramedullary nail, which is straight without curvature but has grooves. CONCLUSION: We removed a broken Kuntscher intramedullary nail without causing an iatrogenic fracture by fenestration of the cortex and rotation of the nail.

14.
J Clin Med ; 13(19)2024 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-39407932

RESUMEN

Background: Owing to the risk of atypical femoral fractures, total hip arthroplasty presents unique challenges for patients with ipsilateral osteoarthritis and localized periosteal thickening in the femoral subtrochanteric region. Stem length selection is critical for minimizing stress concentration in the thickened cortex to avoid such fractures. Herein, we report the case of a 78-year-old woman with ipsilateral hip osteoarthritis and localized subtrochanteric periosteal thickening. Methods: Preoperative planning included a finite element analysis to assess the stress distribution across various stem lengths. A simulation was conducted to determine the optimal stem length to span the cortical thickening and reduce the risk of postoperative complications. Results: The finite element analysis indicated that a stem length of >150 mm was required to effectively reduce the stress at the site of cortical thickening. A 175 mm stem was selected for total hip arthroplasty, which provided a favorable stress distribution and avoided the risk of stress concentration. Conclusions: In cases of ipsilateral osteoarthritis with localized subtrochanteric periosteal thickening, finite element analysis can be valuable for preoperative planning to determine the optimal stem length, thereby reducing the risk of atypical femoral fractures. Further studies with multiple cases are recommended to validate these findings and improve surgical outcomes.

15.
Cureus ; 16(5): e60479, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38882985

RESUMEN

BACKGROUND: We developed a 3D camera system to track motion in a surgical field. This system has the potential to introduce augmented reality (AR) systems non-invasively, eliminating the need for the invasive AR markers conventionally required. The present study was performed to verify the real-time tracking accuracy of this system, assess the feasibility of integrating this system into the surgical workflow, and establish its potential to enhance the accuracy and efficiency of orthopedic procedures. METHODS: To evaluate the accuracy of AR technology using a 3D camera, a forearm bone model was created. The forearm model was depicted using a 3D camera, and its accuracy was verified in terms of the positional relationship with a 3D bone model created from previously imaged CT data. Images of the surgical field (capturing the actual forearm) were taken and saved in nine poses by rotating the forearm from pronation to supination. The alignment of the reference points was computed at the three points of CT versus the three points of the 3D camera, yielding a 3D rotation matrix representing the positional relationship. In the original system, a stereo vision-based 3D camera, with a depth image resolution of 1280×720 pixels, 30 frames per second, and a lens field of view of 64 specifications, with a baseline of 3 cm, capable of optimally acquiring real-time 3D data at a distance of 40-60 cm from the subject was used. In the modified system, the following modifications were made to improve tracking performance: (1) color filter processing was changed from HSV to RGB, (2) positional detection accuracy was modified with supporting marker sizes of 8 mm in diameter, and (3) the detection of marker positions was stabilized by calculating the marker position for each frame. Tracking accuracy was examined with the original system and modified system for the following parameters: differences in the rotation matrix, maximum and minimum inter-reference point errors between CT-based and camera-based 3D data, and the average error for the three reference points. RESULTS: In the original system, the average difference in rotation matrices was 5.51±2.68 mm. Average minimum and maximum errors were 1.10±0.61 and 15.53±12.51 mm, respectively. The average error of reference points was 6.26±4.49 mm. In the modified system, the average difference in rotation matrices was 4.22±1.73 mm. Average minimum and maximum errors were 0.79±0.49 and 1.94±0.87 mm, respectively. The average error of reference points was 1.41±0.58 mm. In the original system, once tracking failed, it was difficult to recover tracking accuracy. This resulted in a large maximum error in supination positions. These issues were resolved by the modified system. Significant improvements were achieved in maximum errors and average errors using the modified system (P<0.05). CONCLUSION: AR technology using a 3D camera was developed. This system allows direct comparisons of 3D data from preoperative CT scans with 3D data acquired from the surgical field using a 3D camera. This method has the advantage of introducing AR into the surgical field without invasive markers.

16.
J Exp Orthop ; 11(3): e12031, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38741903

RESUMEN

Purpose: Thermoelastic stress analysis (TSA) was used to evaluate stress changes over the entire surface of a specimen. This study aimed to assess the relationship between femoral stress distribution, analysed using TSA and changes in bone mineral density (BMD) after total hip arthroplasty (THA). Methods: Stress changes in the simulated bone before and after taper-wedge stem insertion were measured using the TSA. Stress changes were compared with BMD changes around the stem 1 year after surgery in a THA patient (58 hips) with the same taper-wedge stem. Subsequently, we compared the correlation between stress changes and BMD changes. Results: TSA revealed significant stress changes before and after stem insertion, with prominent alterations in the proximal medial region. The BMD changes at 1 year post-THA exhibited a 15%-25% decrease in the proximal zones, while Zones 2-6 showed a -6% to 3% change. Notably, a strong positive correlation (0.886) was found between the stress change rate and BMD change rate. Conclusions: This study demonstrated a high correlation between femoral stress distribution assessed using TSA and subsequent BMD changes after THA. The TSA method offers the potential to predict stress distribution and BMD alterations postsurgery, aiding in implant development and clinical assessment. Combining TSA with finite element analysis could provide even more detailed insights into stress distribution. Level of Evidence: Case series (with or without comparison).

18.
J Arthroplasty ; 28(10): 1736-40, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23540537

RESUMEN

Synergy stems are tapered stems featuring a proximal porous coating, grid blasting below the proximal third to the distal end. This study included 41 patients (50 hips) who underwent total hip arthroplasty with follow-ups for 10 years or more. No stem reimplantations were performed. Spot welds were observed in the distal stem in Gruen zones 3 and 5 in 35 and 32 hips, respectively. First-degree stress shielding occurred in 8 hips; 2nd-degree, 20 hips; 3rd-degree, 13 hips; and 4th-degree, 9 hips. Because of bone fixation to the distal grit-blasted section of the stem, severe stress shielding was observed in nearly half of the cases. Multiple regression analysis of stress shielding determinants revealed a correlation between stem size and short patient height, showing the cause of stress shielding to be a mismatch in size between the stem and the femoral bone.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Resorción Ósea/etiología , Fémur/diagnóstico por imagen , Articulación de la Cadera/cirugía , Prótesis de Cadera/efectos adversos , Artropatías/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Densidad Ósea , Resorción Ósea/diagnóstico por imagen , Femenino , Fémur/fisiopatología , Estudios de Seguimiento , Articulación de la Cadera/diagnóstico por imagen , Humanos , Japón , Artropatías/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Radiografía , Resultado del Tratamiento
19.
Orthop Surg ; 15(6): 1664-1669, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37092528

RESUMEN

OBJECTIVE: During total hip arthroplasty (THA), both pelvic and femur positions affect leg length (LL) and offset (OS) measurements because LL and OS calipers depend on the fixed reference points on the pelvis and femur, respectively. However, LL and OS measurement errors because of pelvic positional changes have not been described. This study aimed to clarify the effects of pelvic positional changes on LL and OS measurements in relation to the pelvic reference using a THA simulator. METHODS: We developed an experimental THA simulator using Sawbones models of the hemipelvis and femur that facilitated modification of the obliquity, tilt, and rotation of the pelvis. Using an LL and OS caliper, LL and OS measurement errors due to pelvic positional changes were determined with the femoral position fixed. Measurements were performed from two pelvic reference positions: the iliac tubercle (P1) and the top of the iliac crest intersecting the line of the femoral long axis (P2). RESULTS: Concerning pelvic obliquity, the total error of LL was 25.0 mm in P1 and 26.5 mm in P2, while the total error of OS was 13.0 mm in P1 and 10.9 mm in P2. For pelvic tilt, the total error of LL was 9.0 mm in P1 and 3.8 mm in P2, while the total error of OS was 0.5 mm in P1 and 1.0 mm in P2. Regarding pelvic rotation, the total error of LL was 13.8 mm in P1 and 3.2 mm in P2, while the total error of OS was 3.8 mm in P1 and 4.0 mm in P2. CONCLUSIONS: Pelvic positional changes alter LL and OS measurements. The acceptable range (error <2 mm) on LL and OS measurement errors of pelvic obliquity was only 2°, regardless of the pelvic reference position. The pelvic reference position should be at the top of the iliac crest intersecting the line of the long axis of the femur because of a small LL measurement error with pelvic tilt and rotation.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Enfermedades Óseas , Humanos , Pierna/cirugía , Pelvis , Extremidad Inferior/cirugía , Fémur/cirugía , Enfermedades Óseas/cirugía
20.
J Orthop Surg Res ; 18(1): 664, 2023 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-37674224

RESUMEN

BACKGROUND: In nerve transfer for peripheral nerve injury, it is sometimes necessary to suture size-mismatched nerves. In 1993, a favorable suture method called the Ochiai suture method for size-mismatched nerve transfer was reported. However, there is currently a lack of substantial evidence beyond the original report. Therefore, this study aimed to verify the advantages of using the Ochiai suture method for size-mismatched nerve transfer. METHODS: A total of 18 rats were evaluated in this study and randomly divided into two groups. All rats underwent femoral to sciatic nerve transfer. Specifically, group A (n = 10) underwent the Ochiai suture method, while group B (n = 8) underwent the perineural suture method. After 12 weeks postoperatively, we conducted the sciatic functional index (SFI) test, measured muscle wet-weight, and performed histological evaluations. All data were compared between the two groups, with Welch's t test for normally distributed data and Mann-Whitney's U test for non-normally distributed data. Statistical significance was set at p < 0.05. RESULTS: The mean number of axons was significantly greater in group A than in group B at 5 mm distal to the stump (p = 0.04). Additionally, the average axonal diameter was significantly greater in group A than in group B at 5 mm and 10 mm distal to the stump (p < 0.01 and p < 0.01, respectively). However, the SFI test and measured muscle wet-weight values showed no significant differences between the two groups. CONCLUSIONS: Our study revealed that the Ochiai suture method for size-mismatched nerve transfer in rats increases the regenerative axon numbers and diameters. These findings suggest that the Ochiai suture method could be a valuable approach for achieving effective motor function restoration in cases of size-mismatched nerve transfer.


Asunto(s)
Transferencia de Nervios , Animales , Ratas , Procedimientos Neuroquirúrgicos , Suturas , Fémur , Músculos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA