Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
J Synchrotron Radiat ; 31(Pt 1): 17-27, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-37947304

RESUMEN

In the energy production and transportation industries, numerous metallic structures may be subjected to at least several billions of cycles, i.e. loaded in the very high cycle fatigue domain (VHCF). Therefore, to design structures in the VHCF domain, a reliable methodology is necessary. One useful quantity to characterize plastic activity at the microscopic scale and fatigue damage evolution is the mechanical work supplied to a material. However, the estimation of this mechanical work in a metal during ultrasonic fatigue tests remains challenging. This paper aims to present an innovative methodology to quantify this. An experimental procedure was developed to estimate the mechanical work from stress and total strain evolution measurements during one loading cycle with a time accuracy of about 50 ns. This was achieved by conducting time-resolved X-ray diffraction coupled to strain gauge measurements at a synchrotron facility working in pulsed mode (single-bunch mode).

2.
J Synchrotron Radiat ; 29(Pt 1): 180-193, 2022 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-34985435

RESUMEN

One of the challenges of all synchrotron facilities is to offer the highest performance detectors for all their specific experiments, in particular for X-ray diffraction imaging and its high throughput data collection. In that context, the DiffAbs beamline, the Detectors and the Design and Engineering groups at Synchrotron SOLEIL, in collaboration with ImXPAD and Cegitek companies, have developed an original and unique detector with a circular shape. This detector is based on the hybrid pixel photon-counting technology and consists of the specific assembly of 20 hybrid pixel array detector (XPAD) modules. This article aims to demonstrate the main characteristics of the CirPAD (for Circular Pixel Array Detector) and its performance - i.e. excellent pixel quality, flat-field correction, high-count-rate performance, etc. Additionally, the powder X-ray diffraction pattern of an LaB6 reference sample is presented and refined. The obtained results demonstrate the high quality of the data recorded from the CirPAD, which allows the proposal of its use to all scientific communities interested in performing experiments at the DiffAbs beamline.

3.
Proc Natl Acad Sci U S A ; 113(34): 9521-6, 2016 08 23.
Artículo en Inglés | MEDLINE | ID: mdl-27503887

RESUMEN

In nature, biomolecules are often organized as functional thin layers in interfacial architectures, the most prominent examples being biological membranes. Biomolecular layers play also important roles in context with biotechnological surfaces, for instance, when they are the result of adsorption processes. For the understanding of many biological or biotechnologically relevant phenomena, detailed structural insight into the involved biomolecular layers is required. Here, we use standing-wave X-ray fluorescence (SWXF) to localize chemical elements in solid-supported lipid and protein layers with near-Ångstrom precision. The technique complements traditional specular reflectometry experiments that merely yield the layers' global density profiles. While earlier work mostly focused on relatively heavy elements, typically metal ions, we show that it is also possible to determine the position of the comparatively light elements S and P, which are found in the most abundant classes of biomolecules and are therefore particularly important. With that, we overcome the need of artificial heavy atom labels, the main obstacle to a broader application of high-resolution SWXF in the fields of biology and soft matter. This work may thus constitute the basis for the label-free, element-specific structural investigation of complex biomolecular layers and biological surfaces.


Asunto(s)
Membrana Dobles de Lípidos/química , Proteolípidos/química , Espectrometría por Rayos X/métodos , Antraquinonas/química , Glicósidos/química , Humanos , Fosfatidilcolinas/química , Albúmina Sérica Humana/química , Soluciones , Espectrometría por Rayos X/instrumentación
4.
Small ; 14(24): e1704514, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29761644

RESUMEN

Van der Waals layered GeTe/Sb2 Te3 superlattices (SLs) have demonstrated outstanding performances for use in resistive memories in so-called interfacial phase-change memory (iPCM) devices. GeTe/Sb2 Te3 SLs are made by periodically stacking ultrathin GeTe and Sb2 Te3 crystalline layers. The mechanism of the resistance change in iPCM devices is still highly debated. Recent experimental studies on SLs grown by molecular beam epitaxy or pulsed laser deposition indicate that the local structure does not correspond to any of the previously proposed structural models. Here, a new insight is given into the complex structure of prototypical GeTe/Sb2 Te3 SLs deposited by magnetron sputtering, which is the used industrial technique for SL growth in iPCM devices. X-ray diffraction analysis shows that the structural quality of the SL depends critically on its stoichiometry. Moreover, high-angle annular dark-field-scanning transmission electron microscopy analysis of the local atomic order in a perfectly stoichiometric SL reveals the absence of GeTe layers, and that Ge atoms intermix with Sb atoms in, for instance, Ge2 Sb2 Te5 blocks. This result shows that an alternative structural model is required to explain the origin of the electrical contrast and the nature of the resistive switching mechanism observed in iPCM devices.

5.
J Synchrotron Radiat ; 25(Pt 1): 204-213, 2018 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-29271769

RESUMEN

This paper describes a method for rapid measurements of the specular X-ray reflectivity signal using an area detector and a monochromatic, well collimated X-ray beam (divergence below 0.01°), combined with a continuous data acquisition mode during the angular movements of the sample and detector. In addition to the total integrated (and background-corrected) reflectivity signal, this approach yields a three-dimensional mapping of the reciprocal space in the vicinity of its origin. Grazing-incidence small-angle scattering signals are recorded simultaneously. Measurements up to high momentum transfer values (close to 0.1 nm-1, also depending on the X-ray beam energy) can be performed in total time ranges as short as 10 s. The measurement time can be reduced by up to 100 times as compared with the classical method using monochromatic X-ray beams, a point detector and rocking scans (integrated reflectivity signal).

6.
J Synchrotron Radiat ; 24(Pt 5): 991-999, 2017 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-28862621

RESUMEN

The new rapid scan method, Flyscan mode, implemented on the DiffAbs beamline at Synchrotron SOLEIL, allows fast micro-X-ray fluorescence data acquisition. It paves the way for applications in the biomedical field where a large amount of data is needed to generate meaningful information for the clinician. This study presents a complete set of data acquired after injection of gold-cluster-enriched mesoporous silica nanospheres, used as potential theranostic vectors, into rats. While classical X-ray fluorescence investigations (using step-by-step acquisitions) are based on a limited number of samples (approximately one per day at the DiffAbs beamline), the Flyscan mode has enabled gathering information on the interaction of nanometer-scale vectors in different organs such as liver, spleen and kidney at the micrometer scale, for five rats, in only a single five-day synchrotron shift. Moreover, numerous X-ray absorption near-edge structure spectra, which are beam-time-consuming taking into account the low concentration of these theranostic vectors, were collected.

7.
Phys Chem Chem Phys ; 19(1): 167-174, 2016 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-27929155

RESUMEN

Ion-surface interactions are of high practical importance in a wide range of technological, environmental and biological problems. In particular, they ultimately control the electric double layer structure, hence the interaction between particles in aqueous solutions. Despite numerous achievements, progress in their understanding is still limited by the lack of experimental determination of the surface composition with appropriate resolution. Tackling this challenge, we have developed a method based on X-ray standing waves coupled to nano-confinement which allows the determination of ion concentrations at a solid-solution interface with a sub-nm resolution. We have investigated mixtures of KCl/CsCl and KCl/KI in 0.1 mM to 10 mM concentrations on silica surfaces and obtained quantitative information on the partition of ions between bulk and Stern layer as well as their distribution in the Stern layer. Regarding partition of potassium ions, our results are in agreement with a recent AFM study. We show that in a mixture of KCl and KI, chloride ions exhibit a higher surface propensity than iodide ions, having a higher concentration within the Stern layer and being on average closer to the surface by ≈1-2 Å, in contrast to the solution water interface. Confronting such data with molecular simulations will lead to a precise understanding of ionic distributions at aqueous interfaces.

8.
Anal Chem ; 87(17): 8827-36, 2015 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-26239283

RESUMEN

Patterns in rare earth element (REE) concentrations are essential instruments to assess geochemical processes in Earth and environmental sciences. Excursions in the "cerium anomaly" are widely used to inform on past redox conditions in sediments. This proxy resources to the specificity of cerium to adopt both the +III and +IV oxidation states, while most rare earths are purely trivalent and share very similar reactivity and transport properties. In practical terms, the level of cerium anomaly is established through elemental point quantification and profiling. All these models rely on a supposed homogeneity of the cerium oxidation state within the samples. However, this has never been demonstrated, whereas the cerium concentration can significantly vary within a sample, as shown for fossils, which would vastly complicate interpretation of REE patterns. Here, we report direct micrometric mapping of Ce speciation through synchrotron X-ray absorption spectroscopy and production of local rare earth patterns in paleontological fossil tissues through X-ray fluorescence mapping. The sensitivity of the approach is demonstrated on well-preserved fishes and crustaceans from the Late Cretaceous (ca. 95 million years (Myr) old). The presence of Ce under the +IV form within the fossil tissues is attributed to slightly oxidative local conditions of burial and agrees well with the limited negative cerium anomaly observed in REE patterns. The [Ce(IV)]/[Ce(tot)] ratio appears remarkably stable at the microscale within each fossil and is similar between fossils from the locality. Speciation maps were obtained from an original combination of synchrotron microbeam X-ray fluorescence, absorption spectroscopy, and diffraction, together with light and electron microscopy. This work also highlights the need for more systematic studies of cerium geochemistry at the microscale in paleontological contexts, in particular across fossil histologies.


Asunto(s)
Cerio/análisis , Fósiles , Animales , Peces , Oxidación-Reducción , Sincrotrones , Espectroscopía de Absorción de Rayos X
9.
Small ; 11(48): 6377-83, 2015 Dec 22.
Artículo en Inglés | MEDLINE | ID: mdl-26540591

RESUMEN

Laterally ordered sub-10 nm features are produced from the directed self-assembly of poly(1,1-dimethyl silacyclo-butane)-block-poly(methyl methacrylate) (PDMSB-b-PMMA) thin films on sinusoidal azobenzene-containing patterns. The use of sinusoidal surface relief grating enables the formation of very large grain areas (over several µm(2) ) consisting of out-of-plane PMMA cylinders.

10.
J Synchrotron Radiat ; 20(Pt 1): 181-9, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23254672

RESUMEN

The newly built MagSAXS (magnetic small-angle X-ray scattering) set-up dedicated to the direct two-dimensional measurement of magnetic scattering using polarized synchrotron radiation in extreme sample environments is presented. Pure optical transport of the image is used to record the magnetic scattering with a two-dimensional CCD visible-light camera. The set-up is able to probe magnetic correlation lengths from the micrometer down to the nanometer scale. A detailed layout is presented along with preliminary results obtained at several beamlines at Synchrotron SOLEIL. The presented examples underline the wide range of possible applications spanning from correlation lengths determination to Fourier transform holography.

11.
J Synchrotron Radiat ; 20(Pt 2): 355-65, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23412494

RESUMEN

X-ray diffraction techniques are used in imaging mode in order to characterize micrometre-sized objects. The samples used as models are metal-oxide tunnel junctions made by optical lithography, with lateral sizes ranging from 150 µm down to 10 µm and various shapes: discs, squares and rectangles. Two approaches are described and compared, both using diffraction contrast: full-field imaging (topography) and raster imaging (scanning probe) using a micrometre-sized focused X-ray beam. It is shown that the full-field image gives access to macroscopic distortions (e.g. sample bending), while the local distortions, at the micrometre scale (e.g. tilts of the crystalline planes in the vicinity of the junction edges), can be accurately characterized only using focused X-ray beams. These local defects are dependent on the junction shape and larger by one order of magnitude than the macroscopic curvature of the sample.

12.
J Synchrotron Radiat ; 20(Pt 1): 105-9, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23254662

RESUMEN

Natural rubber exhibits remarkable mechanical fatigue properties usually attributed to strain-induced crystallization. To investigate this phenomenon, an original experimental set-up that couples synchrotron radiation with a homemade fatigue machine has been developed. Diffraction-pattern recording is synchronized with cyclic loading in order to obtain spatial distributions of crystallinity in the sample at prescribed times of the mechanical cycles. Then, real-time measurement of crystallinity is permitted during uninterrupted fatigue experiments. First results demonstrate the relevance of the method: the set-up is successfully used to measure the crystallinity distribution around a fatigue crack tip in a carbon black filled natural rubber for different loading conditions.

13.
Micron ; 173: 103507, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37478722

RESUMEN

The microstructure and texture of the intermetallics in Al/Mg/Al multi-layer composite fabricated by Accumulative Roll Bonding (ARB) at 400 °C up to 6 cycles were investigated using Electron BackScatter Diffraction (EBSD) and Synchrotron X-ray Diffraction (SXRD). EBSD and SXRD analysis have shown that ARB processing leads to the formation of Al3Mg2 and Mg17Al12 intermetallics soon after the second ARB cycle with a global thickness of 12 (N = 2) to 22 µm (N = 6). The polycrystalline intermetallics plates growth was columnar and normal to the bonding interface. A constitutional liquefaction region was depicted ahead of the plates with an unusual rugged migration front. The Al3Mg2 and Mg17Al12 intermetallic compounds which formed after 2 ARB cycles have approximately the same average grain size (1.0 µm) at this cycle. After 4 ARB cycles, the grain refinement of Al3Mg2 is more than 4 times higher than in Mg17Al12. The average grain size of Al3Mg2 and Mg17Al12 reach 0.2 and 0.9 µm, respectively. After 6 cycles of ARB, the average grain size of both Al3Mg2 and Mg17Al12 increased to 1.5 µm and 2.8 µm, respectively. The dislocation density obeyed a ρAl3Mg2 > ρAZ31 > ρAl 1050 ∼ ρMg17Al12 hierarchy after N = 4 and 6 ARB cycles and the Al3Mg2 was shown to store more dislocations. Through the ARB processing, a usual strong basal (0002) texture was depicted in AZ31 layers and a weak rolling texture was shown in Al 1050 layers with a dominant Rotated Cube (001) 110 > component that vanished after upon increasing ARB cycles. The Al3Mg2 and Mg17Al12 intermetallics were characterized by a random texture.

14.
Adv Sci (Weinh) ; 9(32): e2203834, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36116124

RESUMEN

Transient liquid assisted growth (TLAG) is an ultrafast non-equilibrium growth process mainly governed by kinetic parameters, which are only accessible through fast in situ characterizations. In situ synchrotron X-ray diffraction (XRD) analysis and in situ electrical resistivity measurements are used to derive kinetic diagrams of YBa2 Cu3 O7- x (YBCO) superconducting films prepared via TLAG and to reveal the unique peculiarities of the process. In particular, diagrams for the phase evolution and the YBCO growth rates have been built for the two TLAG routes. It is shown that TLAG transient liquids can be obtained upon the melting of two barium cuprate phases (and not just one), differentiated by their copper oxidation state. This knowledge serves as a guide to determine the processing conditions to reach high performance films at high growth rates. With proper control of these kinetic parameters, films with critical current densities of 2-2.6 MA cm-2 at 77 K and growth rates between 100-2000 nm s-1 are reached. These growth rates are 1.5-3 orders of magnitude higher than those of conventional methods.

15.
J Synchrotron Radiat ; 18(Pt 6): 907-11, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21997916

RESUMEN

An in situ tensile-shear loading device has been designed to study elastomer crystallization using synchrotron X-ray scattering at the Synchrotron Soleil on the DiffAbs beamline. Elastomer tape specimens of thickness 2 mm can be elongated by up to 500% in the longitudinal direction and sheared by up to 200% in the transverse direction. The device is fully automated and plugged into the TANGO control system of the beamline allowing synchronization between acquisition and loading sequences. Experimental results revealing the evolution of crystallization peaks under load are presented for several tension/shear loading sequences.


Asunto(s)
Cristalización , Elastómeros/química , Goma/química , Dispersión de Radiación , Estrés Mecánico , Sincrotrones , Resistencia a la Tracción , Difracción de Rayos X , Rayos X
16.
ACS Appl Mater Interfaces ; 13(7): 9101-9112, 2021 Feb 24.
Artículo en Inglés | MEDLINE | ID: mdl-33576610

RESUMEN

Combinatorial and high-throughput experimentation (HTE) is achieving more relevance in material design, representing a turning point in the process of accelerated discovery, development, and optimization of materials based on data-driven approaches. The versatility of drop-on-demand inkjet printing (IJP) allows performing combinatorial studies through fabrication of compositionally graded materials with high spatial precision, here by mixing superconducting REBCO precursor solutions with different rare earth (RE) elements. The homogeneity of combinatorial Y1-xGdxBa2Cu3O7 samples was designed with computational methods and confirmed by energy-dispersive X-ray spectroscopy (EDX) and high-resolution X-ray diffraction (XRD). We reveal the advantages of this strategy in the optimization of the epitaxial growth of high-temperature REBCO superconducting films using the novel transient liquid-assisted growth method (TLAG). Advanced characterization methods, such as in situ synchrotron growth experiments, are tailored to suit the combinatorial approach and demonstrated to be essential for HTE schemes. The experimental strategy presented is key for the attainment of large datasets for the implementation of machine learning backed material design frameworks.

17.
J Synchrotron Radiat ; 17(3): 299-307, 2010 May.
Artículo en Inglés | MEDLINE | ID: mdl-20400826

RESUMEN

A study of the coherence and wavefront properties of a pseudo-channel-cut monochromator in comparison with a double-crystal monochromator is presented. Using a double-grating interferometer designed for the hard X-ray regime, the complex coherence factor was measured and the wavefront distortions at the sample position were analyzed. A transverse coherence length was found in the vertical direction that was a factor of two larger for the channel-cut monochromator owing to its higher mechanical stability. The wavefront distortions after different optical elements in the beam, such as monochromators and mirrors, were also quantified. This work is particularly relevant for coherent diffraction imaging experiments with synchrotron sources.

18.
Materials (Basel) ; 13(18)2020 Sep 11.
Artículo en Inglés | MEDLINE | ID: mdl-32932785

RESUMEN

Ni and Ni(W) solid solution of bulk Ni and Ni-W alloys (Ni-10W, Ni-30W, and Ni-50W) (wt%) were mechanically compared through the evolution of their {111} X-ray diffraction peaks during in situ tensile tests on the DiffAbs beamline at the Synchrotron SOLEIL. A significant difference in terms of strain heterogeneities and lattice strain evolution occurred as the plastic activity increased. Such differences are attributed to the number of brittle W clusters and the hardening due to the solid solution compared to the single-phase bulk Ni sample.

19.
Materials (Basel) ; 13(15)2020 Jul 27.
Artículo en Inglés | MEDLINE | ID: mdl-32727047

RESUMEN

The piezoelectric properties of lanthanum-modified lead zirconate titanate Pb1-xLax(Zr0.52Ti0.48)1-x/4O3 thin films, with x = 0, 3 and 12 mol% La, were studied by in situ synchrotron X-ray diffraction under direct (DC) and alternating (AC) electric fields, with AC frequencies covering more than four orders of magnitude. The Bragg reflections for thin films with low lanthanum concentration exhibit a double-peak structure, indicating two contributions, whereas thin films with 12% La possess a well-defined Bragg peak with a single component. In addition, built-in electric fields are revealed for low La concentrations, while they are absent for thin films with 12% of La. For static and low frequency AC electric fields, all lanthanum-modified lead zirconate titanate thin films exhibit butterfly loops, whereas linear piezoelectric behavior is found for AC frequencies larger than 1 Hz.

20.
J R Soc Interface ; 17(169): 20200216, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32842887

RESUMEN

Fossils, including those that occasionally preserve decay-prone soft tissues, are mostly made of minerals. Accessing their chemical composition provides unique insight into their past biology and/or the mechanisms by which they preserve, leading to a series of developments in chemical and elemental imaging. However, the mineral composition of fossils, particularly where soft tissues are preserved, is often only inferred indirectly from elemental data, while X-ray diffraction that specifically provides phase identification received little attention. Here, we show the use of synchrotron radiation to generate not only X-ray fluorescence elemental maps of a fossil, but also mineralogical maps in transmission geometry using a two-dimensional area detector placed behind the fossil. This innovative approach was applied to millimetre-thick cross-sections prepared through three-dimensionally preserved fossils, as well as to compressed fossils. It identifies and maps mineral phases and their distribution at the microscale over centimetre-sized areas, benefitting from the elemental information collected synchronously, and further informs on texture (preferential orientation), crystallite size and local strain. Probing such crystallographic information is instrumental in defining mineralization sequences, reconstructing the fossilization environment and constraining preservation biases. Similarly, this approach could potentially provide new knowledge on other (bio)mineralization processes in environmental sciences. We also illustrate that mineralogical contrasts between fossil tissues and/or the encasing sedimentary matrix can be used to visualize hidden anatomies in fossils.


Asunto(s)
Fósiles , Sincrotrones , Radiografía , Difracción de Rayos X , Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA