Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
J Endovasc Ther ; : 15266028241270861, 2024 Aug 27.
Artículo en Inglés | MEDLINE | ID: mdl-39188184

RESUMEN

PURPOSE: Endovascular aortic repair (EVAR) is currently expanding its feasibility thanks to design innovations, but hostile proximal necks and narrow iliac arteries are still a constraint, as expressed by the Instructions for Use (IFU) of most devices. Our aim is to report the preliminary results of the E-Tegra endograft in infrarenal abdominal aortic aneurysms (AAAs) performed in 15 high-volume centers. MATERIALS AND METHODS: The e-Tegra Italian endoGraft REgistry (TIGRE) is a prospectively maintained database of consecutive EVAR with the E-Tegra stent-graft across 15 participating centers between March 2021 and March 2023. The registry records baseline clinical data, anatomic measurements of the abdominal aorta, perioperative and postoperative outcomes, with a scheduled follow-up period of 3 years for all patients. This is a preliminary analysis of the first results updated to January 2024. The primary endpoints are technical and clinical success, perioperative mortality, freedom from endograft rupture, and aortic-related mortality. The secondary endpoints are freedom from reintervention, and any type of endoleak (EL). The results were analyzed in relation with the anatomic characteristics of the AAAs, namely, iliac axes tortuosity and proximal neck hostility. RESULTS: The registry included 147 consecutive EVAR (138 elective and 9 in emergent setting), 7 of which were associated with an iliac branch implantation. Ninety patients had at least 1 criterion of anatomical hostility, and 25 were treated outside the device IFU. Primary technical success was achieved in 146 cases (99.3%) and assisted success in 147 (100%), with no perioperative mortality. After a median follow-up period of 20 months, no aneurysm-related mortality occurred. Reinterventions were 5: 2 for type IB EL and 3 for type II ELs with aneurysm sac increase. Five more type II ELs with aneurysm sac stability are under observation. No differences in terms of reinterventions were noted between aneurysms with standard and hostile anatomy. CONCLUSION: The E-Tegra endograft is safe and effective in treating AAAs with standard and hostile anatomy, with a low rate of complications and reinterventions, although longer-term outcomes and larger numbers are needed to compare its performances related to specific anatomic criteria. CLINICAL IMPACT: This multi-center nationwide Registry reports a real-world experience of EVAR performed with the E-Tegra abdominal endograft across 15 high-volume Centers, providing early- and mid-term device-specific results, which will help vascular surgeons in endograft selection. In particular, this study focuses on clinical results obtained in treating aneurysms with hostile anatomy, analyzing the performances of the E-Tegra endograft in cases of hostile proximal necks and narrow or tortuous iliac axes.

2.
Radiol Med ; 127(7): 743-753, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35680773

RESUMEN

PURPOSES: Radiomics is a quantitative method able to analyze a high-throughput extraction of minable imaging features. Herein, we aim to develop a CT angiography-based radiomics analysis and machine learning model for carotid plaques to discriminate vulnerable from no vulnerable plaques. MATERIALS AND METHODS: Thirty consecutive patients with carotid atherosclerosis were enrolled in this pilot study. At surgery, a binary classification of plaques was adopted ("hard" vs "soft"). Feature extraction was performed using the R software package Moddicom. Pairwise feature interdependencies were evaluated using the Spearman rank correlation coefficient. A univariate analysis was performed to assess the association between each feature and the plaque classification and chose top-ranked features. The feature predictive value was investigated using binary logistic regression. A stepwise backward elimination procedure was performed to minimize the Akaike information criterion (AIC). The final significant features were used to build the models for binary classification of carotid plaques, including logistic regression (LR), support vector machine (SVM), and classification and regression tree analysis (CART). All models were cross-validated using fivefold cross validation. Class-specific accuracy, precision, recall and F-measure evaluation metrics were used to quantify classifier output quality. RESULTS: A total of 230 radiomics features were extracted from each plaque. Pairwise Spearman correlation between features reported a high level of correlations, with more than 80% correlating with at least one other feature at |ρ|> 0.8. After a stepwise backward elimination procedure, the entropy and volume features were found to be the most significantly associated with the two plaque groups (p < 0.001), with AUCs of 0.92 and 0.96, respectively. The best performance was registered by the SVM classifier with the RBF kernel, with accuracy, precision, recall and F-score equal to 86.7, 92.9, 81.3 and 86.7%, respectively. The CART classification tree model for the entropy and volume features model achieved 86.7% well-classified plaques and an AUC of 0.987. CONCLUSION: This pilot study highlighted the potential of CTA-based radiomics and machine learning to discriminate plaque composition. This new approach has the potential to provide a reliable method to improve risk stratification in patients with carotid atherosclerosis.


Asunto(s)
Enfermedades de las Arterias Carótidas , Placa Aterosclerótica , Algoritmos , Arterias Carótidas , Enfermedades de las Arterias Carótidas/diagnóstico por imagen , Angiografía por Tomografía Computarizada , Humanos , Proyectos Piloto , Placa Aterosclerótica/diagnóstico por imagen
3.
J Endovasc Ther ; 21(3): 410-3, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24915590

RESUMEN

PURPOSE: To describe the successful management of a symptomatic persistent sciatic artery (PSA) aneurysm using the Multilayer Aneurysm Repair System (MARS). CASE REPORT: A 50-year-old man with history of smoking, hypertension, and hypercholesterolemia suddenly developed pain in the buttock radiating to the left lower limb, mimicking sciatica. The ∼57×54-mm incomplete type PSA aneurysm was treated with two 14×80- and 14×60-mm MARS devices through a surgical left axillary artery access. There were no periprocedural complications. Thirty-day imaging documented patency of the stents and a minor reduction (∼47×55 mm) in the aneurysm, with slightly hyperdense content and no signs of perfusion. At 6 months, duplex and computed tomographic angiography showed complete thrombosis of the sac, patency of the multilayer stents, and further aneurysm shrinkage (40×37 mm). CONCLUSION: The multilayer stent can alter the hemodynamics inside a peripheral aneurysm to promote sac thrombosis and redirect flow to collaterals originating from the sac.


Asunto(s)
Aneurisma/terapia , Arterias/anomalías , Procedimientos Endovasculares/instrumentación , Extremidad Inferior/irrigación sanguínea , Stents , Aneurisma/diagnóstico , Aneurisma/fisiopatología , Arterias/diagnóstico por imagen , Arterias/fisiopatología , Hemodinámica , Humanos , Angiografía por Resonancia Magnética , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Ultrasonografía Doppler Dúplex , Grado de Desobstrucción Vascular
4.
SAGE Open Med Case Rep ; 12: 2050313X241236328, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38784242

RESUMEN

Thoracic endovascular aortic repair is nowadays the preferred option to manage descending thoracic aorta diseases. However, despite feasibility and safety of the procedures, several complications may occur. We report the case of an 83-year-old female patient with inadvertent iliac rupture occurred during thoracic endovascular aortic repair. To limit massive bleeding, considering the patient's comorbidities contraindicating open surgical repair and the morphology of the arterial injury (circumferential rupture of the artery from its origin), we chose to perform a homolateral hypogastric and common iliac artery embolization and an aorto-uniliac balloon expandable stent graft deployment from the distal aorta to the contralateral common iliac artery. A femoro-femoral crossover bypass graft was performed to restore both lower limbs perfusion. Final angiography documented correct positioning and regular patency of the implanted grafts and bypass with no blood loss from the right iliac vessels. Despite careful preoperative assessment, iliac artery injury can represent a challenging complication of thoracic endovascular aortic repair, particularly in the setting of inadequate iliac diameter, calcification and vessel tortuosity, or when large-caliber introducers are required. The hybrid approach we describe is a valid and effective solution to minimize blood loss and avoid major consequences in the management of iatrogenic iliac artery rupture during endovascular procedures.

5.
Angiology ; : 33197231190512, 2023 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-37728082

RESUMEN

We evaluated the use of autologus bone marrow stem cells transplantation in patients with critical limb ischaemia (CLI) not eligible for revascularization. Eighty consecutive patients candidate to amputation were enrolled in a single-centre retrospective study. The primary endpoint was defined as the amputation-free rate from stem cells transplantation. Secondary endpoints were the evaluation of transcutaneous oximetry and its predictive potential for probability of amputation and the evaluation of rest pain. Ankle brachial index, transcutaneous oxygen (TcpO2) and radiological imaging were performed at the enrolment and during the follow-up times. All patients were treated with auto transplant of bone marrow stem cells. Two patients died due to acute renal and acute respiratory failures. 19 patients were amputated from the thigh or leg. In total, 59 of 80 patients intended to thigh amputation saved the limb, preserving the plantar support. TcpO2 was found a predictive metric with an AUC equal to .763, and a threshold for a risk of amputation of 10% and 5% at the values ≤22.7 and ≤26.9 mmHg, respectively. Auto transplant of bone marrow stem cells seems to be a safe and an efficient option for CLI not eligible to revascularizzation.

7.
Life (Basel) ; 12(11)2022 Oct 22.
Artículo en Inglés | MEDLINE | ID: mdl-36362834

RESUMEN

We aimed to perform an anatomical evaluation of the carotid bulb using CT-angiography, implement a new reliable index for carotid stenosis quantification and to assess the accuracy of relationship between NASCET and ECST methods in a large adult population. The cross-sectional areas of the healthy carotid at five levels were measured by two experienced radiologists. A regression analysis was performed in order to quantify the relationship between the areas of the carotid bulb at different carotid bulbar level. A new index (Regression indeX, RegX) for carotid stenosis quantification was proposed. Five different stenoses with different grade in three bulbar locations were simulated for all patients for a total of 1365 stenoses and were used for a direct comparison of the RegX, NASCET, and ECST methods. The results of this study demonstrated that the RegX index provided a consistent and accurate measure of carotid stenosis through the application of the ECST method, avoiding the limitations of NASCET method. Furthermore, our results strongly depart from the consolidated relationships between NASCET and ECST values used in clinical practice and reported in extensive medical literature. In particular, we highlighted that a major misdiagnosis in patient selection for CEA could be introduced because of the large underestimation of real stenosis degree provided by the NASCET method. A reappraisal of carotid stenosis patients' work-up is evoked by the effectiveness of state-of-the-art noninvasive contemporary carotid imaging.

8.
SAGE Open Med Case Rep ; 10: 2050313X221109973, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35899246

RESUMEN

Chronic-contained rupture of an aortic aneurysm is a rare subset of ruptured aneurysms. The presentation is unusual, and the diagnosis is frequently delayed. Here, we describe a case of contained rupture of abdominal aortic aneurysm that presented with signs and symptoms of femoral neuropathy. Clinical and radiological findings were initially misinterpreted. The correct diagnosis was formulated belatedly, causing a progressively increased risk of fatal events. Surgical aortic repair was performed and the postoperative course was uneventful. In conclusion, in the presence of a retroperitoneal mass, a diagnosis of chronic-contained rupture of an abdominal aortic aneurysm should be considered.

9.
Vasc Endovascular Surg ; 56(6): 566-570, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35499500

RESUMEN

INTRODUCTION: Carotid atherosclerotic disease is a known independent risk factor of post operative stroke after coronary artery bypass grafting (CABG). The best management of concomitant coronary artery disease and carotid artery disease remains debated. Current strategies include simultaneous carotid endoarterectomy (CEA) and CABG, staged CEA followed by CABG, staged CABG followed by CEA, staged transfemoral carotid artery stenting (TF-CAS) followed by CABG, simultaneous TF-CAS and CABG and transcarotid artery stenting. METHODS: We report our experience based on a cohort of 222 patients undergoing combined CEA and CABG surgery who come to our observation from 2004 to 2020. All patients with >70% carotid stenosis and severe multivessel or common truncal coronary artery disease underwent combined CEA and CABG surgery at our instituion. 30% of patients had previously remote neurological symptoms or a cerebral CT-scan with ischemic lesions. Patients with carotid stenosis >70%, either asymptomatic or symptomatic, underwent CT-scan without contrast media to assess ischemic brain injury, and in some cases, if necessary, CT-angiography of the neck and intracranial vessels. RESULTS: The overall perioperative mortality rate was 4.1% (9/222 patients). Two patients (.9%) had periprocedural ipsilateral transient ischemic attack (TIA) which completely resolved by the second postoperative day. Two patients (.9%) had an ipsilateral stroke, while 7 patients (3.2%) had a stroke of the controlateral brain hemisphere. Two patients (.9%) patients were affected by periprocedural coma caused by cerebral hypoperfusion due to perioperative heart failure. There were no statistically significant differences between patients in Extracorporeal Circulation (ECC) and Off-pump patients in the onset of perioperative stroke. CONCLUSION: Our experience reported that combined surgical treatment of CEA and CABG, possibly Off-Pump, is a feasible treatment procedure, able to minimize the risk of post-operative stroke and cognitive deficits.


Asunto(s)
Enfermedades de las Arterias Carótidas , Estenosis Carotídea , Enfermedad de la Arteria Coronaria , Endarterectomía Carotidea , Accidente Cerebrovascular , Enfermedades de las Arterias Carótidas/complicaciones , Estenosis Carotídea/complicaciones , Estenosis Carotídea/diagnóstico por imagen , Estenosis Carotídea/cirugía , Puente de Arteria Coronaria/efectos adversos , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Endarterectomía Carotidea/efectos adversos , Humanos , Stents/efectos adversos , Accidente Cerebrovascular/complicaciones , Accidente Cerebrovascular/etiología , Resultado del Tratamiento
10.
SAGE Open Med Case Rep ; 9: 2050313X20983207, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33456776

RESUMEN

We reported four cases of intramural haematoma of the descending thoracic aorta. Four patients, aged 55-82 years, hypertensive, were transferred from the emergency room of other hospitals due to the appearance of epigastric pain and left thorax pain. All patients underwent computed tomography angiography reporting the presence of intramural haematoma. Three patients underwent a drug therapy to maintain a controlled hypotension. A computed tomography revaluation was performed documenting (1) an increase in the thickness of the intramural haematoma, (2) the appearance of a penetrating ulcer within the haematoma and (3) the appearance of several penetrating lesions throughout the thoracic aorta. Patients required the placement of one or two thoracic aorta endoprosthesis. For the fourth patient, the hyperdense appearance of the intramural haematoma and the presence of pleural effusion suggested an urgent treatment intervention. All patients underwent a placement of cerebrospinal fluid catheter and drainage before treatment. All patients were treated with endovascular intervention with 100% technical success and absence of migration or retrograde type A dissection. There were no complications related to femoral surgical access or access routes. Perioperative mortality was null; no patient had paraplegia. No strokes, transient ischemic attack or perioperative myocardial infarction were observed. The average hospitalization was 5 days. After 3 months, angio-computed tomography reported for all patients a complete reabsorption of the intramural haematoma and a complete exclusion of the penetrating ulcer of the aortic wall present at the time of the intervention. There have been no cases of distant thoracic aortic tears. Endovascular treatment must be considered the preeminent treatment for thoracic aortic haematoma. Best timing to perform the endovascular procedure depends on the patient clinical picture and on stability of hemodynamic parameters.

11.
Biomedicines ; 9(4)2021 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-33917851

RESUMEN

Atherosclerotic plaque instability and rupture in patients with asymptomatic carotid artery stenosis (ACAS) is a leading cause of major adverse cardiac events (MACE). This could be mainly evidenced in patients with pre-diabetes. Indeed, the altered glucose homeostasis and insulin resistance could cause over-inflammation of atherosclerotic plaque, favoring its conversion to unstable phenotype with rupture and MACE. Notably, metformin therapy reducing the metabolic distress and the inflammatory burden could reduce MACE in ACAS patients with pre-diabetes. In this setting, the microRNAs (miRs) could be used as molecular biomarkers of atherosclerosis progression, plaque rupture, and worse prognosis in normoglycemics (NG) versus pre-diabetics metformin users (PDMU) versus pre-diabetics non-metformin users (PDNMU). However, our study aimed to investigate a wide miRNA panel in peripheral blood exosomes from patients with ACAS divided in NG versus PDMU versus PDNMU, and to associate the circulating miRNA expression profiles with MACE at 2 years of follow-up after endarterectomy. The study included 234 patients with ACAS divided into NG (n = 125), PDNMU (n = 73), and PDMU (n = 36). The miRs' expression profiles of circulating exosomes were determined at baseline and at 2 years of follow-up by Affymetrix microarrays from the patients' plasma samples from any study cohort. Then we collected and analyzed MACE at 2 years of follow-up in NG versus PDMU versus PDNMU. Prediabetics versus NG had over-inflammation (p < 0.05) and over expressed miR-24 and miR-27 at baseline. At 2 years of follow-up, PDNMU versus NG, PDMU versus NG, and PDNMU versus PDMU over-expressed inflammatory markers and miR-24, miR-27, miR-100, miR-126, and miR-133 (p < 0.05). Finally, at the end of follow-up, we observed a significant difference about MACE comparing PDNMU versus NG (n = 27 (36.9%) versus n = 8 (6.4%); p < 0.05), PDNMU versus PDMU (n = 27 (36.9%) versus n = 6 (16.6%); p < 0.05); and PDMU versus NG (n = 6 (16.6%) versus n = 8 (6.4%); p < 0.05). Admission glucose values (HR (hazard ratio) 1.020, CI (confidence of interval) 95% (1.001-1.038), p = 0.029), atheromatous carotid plaque (HR 5.373, CI 95% (1.251-11.079), p = 0.024), and miR-24 (HR 3.842, CI 95% (1.768-19.222), p = 0.011) predicted MACE at 2 years of follow-up. Specific circulating miRs could be over-expressed in pre-diabetics and specifically in PDNMU versus PDMU after endarterectomy. MiR24, hyperglycemia, and atheromatous plaque could predict MACE at 2 years of follow-up.

12.
Radiol Case Rep ; 13(2): 328-332, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29904466

RESUMEN

We described the utility of computed tomography (CT) angiography in detection of bleeding vessels for a rapid percutaneous arterial embolization of the spontaneous rectus sheath hematoma. A 70-year-old woman comes to our attention with acute abdominal pain and a low hemoglobin level. An unenhanced CT was performed demonstrating a large rectus sheath hematoma. A conservative management was initially established. Despite this therapy, the abdominal pain increased together with a further decrease of hemoglobin values. A CT angiography was then performed, demonstrating an active bleeding within the hematoma and addressing the patient to a rapid percutaneous arterial embolization.

13.
Vasc Endovascular Surg ; 41(5): 448-51, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17942861

RESUMEN

The purpose of this report is to present the case of a 59-year-old man affected by multivessel coronary artery disease and sterile pseudoaneurysm of the right carotid bifurcation presenting as a pulsating neck mass 1 month after patch-free carotid endarterectomy. The surgical approach included median sternotomy and incision parallel to the anterior margin of the right sternocleidomastoid muscle. The pseudoaneurysm was excised after control of the brachiocefalic trunk and insertion of a Pruit-Inahara shunt, and the carotid vessels were directly sutured without using any prosthetic or autologous material. Concomitant coronary bypass grafting was performed. The postoperative course was uneventful and there was no evidence of recurrence of pseudoaneurysm at 6-month follow-up. On the basis of this experience and of pertinent literature, the options for the management of such rare entities are discussed.


Asunto(s)
Traumatismos de las Arterias Carótidas/etiología , Estenosis Carotídea/cirugía , Endarterectomía Carotidea/efectos adversos , Anastomosis Quirúrgica , Traumatismos de las Arterias Carótidas/complicaciones , Traumatismos de las Arterias Carótidas/patología , Traumatismos de las Arterias Carótidas/cirugía , Puente de Arteria Coronaria , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/cirugía , Humanos , Angiografía por Resonancia Magnética , Masculino , Persona de Mediana Edad , Técnicas de Sutura , Resultado del Tratamiento
14.
J Clin Imaging Sci ; 7: 30, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28852580

RESUMEN

The presence of simultaneous two ectopic foci of thyroid tissue (dual ectopic thyroid) is rare, and few cases have been reported in the literature. The ectopic thyroid tissue is an extremely uncommon embryological aberration due to the alterations occurring during the embryological development with incomplete migration of thyroid precursors. Commonly ectopic thyroid tissue is a midline structures, but the lateral location is possible but very rare. Ectopic thyroid is common in women and can vary in size from a microscopic focus to a few centimeters. The normal process of migration of the thyroid can be interrupted at various levels determining a lingual ectopy, a sublingual ectopic, prelaryngeal ectopy, or mediastinic ectopy. Intrathoracic and subdiaphragmatic organs are other sites where the ectopic thyroid tissue may be present. In most of the cases, ectopic tissue is a lingual thyroid and this condition can be totally asymptomatic, discovered incidentally, or occurs with symptoms such as dysphonia, dysphagia, dyspnea, and hemoptysis. Sublingual or suprahyoid ectopia is rare and even rarer are the cases of two foci of ectopic thyroid tissue simultaneously present. On imaging, the ectopic tissue shows the same characteristics of orthotopic thyroid tissue and similarly can undergo goiterous and cancerous transformation. We report a case of incidental dual ectopic thyroid in lingual and suprahyoid level in a 72-year-old female patient, asymptomatic and with normal thyroid function, who underwent computed tomography (CT) angiography before vascular surgery for the treatment of carotid stenosis. The presence of a lingual thyroid can lead to a difficult and dangerous intubation, with possible fatal consequences. For this reason, the discovery of these abnormalities has totally changed the patient management who has been subjected to endovascular treatment, instead to the classical surgery.

15.
Chest ; 128(3): 1587-92, 2005 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-16162762

RESUMEN

INTRODUCTION AND BACKGROUND: Myocardial revascularization using internal thoracic arteries (ITAs) has been associated with superior clinical outcome. This study addresses the question of whether internal mammary arteries are unsuitable for grafting due to radiation-based damage in patients with history of thoracic radiation therapy. We review our experience in this subset of surgical candidates. PATIENTS AND METHODS: Forty-nine patients undergoing elective coronary artery bypass grafting with use of at least one ITA were enrolled and matched to 49 comparable nonirradiated individuals by propensity scoring system. Preoperative and postoperative data were collected and compared. A 18-month clinical follow-up was performed. RESULTS: Intraoperative mammary artery flow was assessed by transthoracic Doppler echocardiography probe, and there was no significant difference between irradiated and nonirradiated individuals (36 +/- 8.3 mL/min vs 39 +/- 7.2 mL/min, p = 0.15). The two study groups were also comparable in terms of survival (overall mortality, 2%) and recurrence of angina and perfusion defect at control stress perfusion nuclear scan (p = 0.99 and p = 0.77, respectively). One arterial graft showed stenosis at postoperative angiography. The dose of radiation therapy administered did not correlate with graft flow values after anastomosis. CONCLUSION: Our data suggest that the use of a monolateral or bilateral ITA is not associated with early graft failure in patients with history of chest/mediastinal irradiation. Skeletonization harvesting technique might be recommended because of the frequent presence of fibrous tissue around the in situ vessel. Arterial graft stenosis in thorax-irradiated patients should be attributed to the primary atherosclerotic disease rather than to irradiation itself.


Asunto(s)
Oclusión de Injerto Vascular/etiología , Anastomosis Interna Mamario-Coronaria/efectos adversos , Arterias Mamarias/efectos de la radiación , Radioterapia/efectos adversos , Anciano , Anciano de 80 o más Años , Ecocardiografía Doppler , Femenino , Estudios de Seguimiento , Oclusión de Injerto Vascular/diagnóstico por imagen , Humanos , Masculino , Arterias Mamarias/diagnóstico por imagen , Persona de Mediana Edad , Tórax
16.
Chir Ital ; 56(2): 229-38, 2004.
Artículo en Inglés | MEDLINE | ID: mdl-15152515

RESUMEN

This study is a retrospective analysis of the impact of intravascular ultrasound in addiction to conventional angiography in 36 patients with 55 stenotic peripheral arterial lesions treated with angioplasty and/or stenting. Before treatment, intravascular ultrasound imaging showed that the vessel diameter was underestimated with angiography in 6 cases. The correlation index between angiography and intravascular ultrasound measurements, however, was significant in 27 arterial lesions. After endovascular treatment, angiography showed 3 vessel dissections and no incomplete stent deployment, whereas intravascular ultrasound showed 15 dissections and 5 instances of stent underdeployment. If we consider the intravascular ultrasound data as the gold standard, the specificity of angiography is 100%, while its sensitivity is 56% for vessel dissection and 75% for stent deployment. In the follow up of the 16 patients treated for iliac lesions with intravascular ultrasound control, re-stenosis occurred in 5% (primary patency 94.7%); in a control group of 15 patients treated in the same period without intravascular ultrasound control, re-stenosis occurred in 15.8% (primary patency 83.4%, difference not statistically significant). In conclusion, in the peripheral arteries intravascular ultrasound is more accurate than arteriography in evaluating dissection and stent deployment, but the routine use of intravascular ultrasound in every case of iliac PTA or stenting would not appear justified.


Asunto(s)
Angioplastia de Balón , Arteriosclerosis/diagnóstico por imagen , Arteriosclerosis/cirugía , Ultrasonografía Intervencional , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Stents
17.
Chir Ital ; 54(5): 693-8, 2002.
Artículo en Italiano | MEDLINE | ID: mdl-12469467

RESUMEN

This study reports on 10 years of experience in observing diverticular disease. The study considers 77 patients, 41 males and 36 females, aged from 50 to 88 years (mean age: 70 years), observed from January 1991 to December 2001. Sixty-two patients were admitted from the Accident and Emergency Unit and 15 were elected patients. Five patients underwent emergency surgery, while 72 received only antibiotic therapy. The overall mortality rate was 0. The morbidity rate was 22% in those patients undergoing emergency surgery. In only one of the elected patients was wound suppuration detected. Diverticular disease, in most cases, is treated by antibiotic therapy alone, but in 30% of cases surgery is necessary. Colon resection and immediate anastomosis are the first choice operation also in the emergency setting, provided local conditions (inflammation, septic contamination) make anastomosis safe. In patients with major peritoneal contamination, Hartman's operation and subsequent recanalization after 6 months are to be preferred.


Asunto(s)
Divertículo del Colon , Anciano , Anciano de 80 o más Años , Antibacterianos/uso terapéutico , Diverticulitis del Colon/diagnóstico , Diverticulitis del Colon/etiología , Diverticulitis del Colon/cirugía , Diverticulitis del Colon/terapia , Divertículo del Colon/complicaciones , Divertículo del Colon/tratamiento farmacológico , Divertículo del Colon/cirugía , Urgencias Médicas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Enfermedades del Sigmoide/complicaciones , Enfermedades del Sigmoide/diagnóstico , Enfermedades del Sigmoide/tratamiento farmacológico , Enfermedades del Sigmoide/cirugía
18.
Chir Ital ; 54(4): 569-72, 2002.
Artículo en Inglés | MEDLINE | ID: mdl-12239771

RESUMEN

The aim of this study is to report the experience of a case of benign multicystic mesothelioma of the peritoneum presented with acute appendicitis symptomatology. A 28 years old man with right lower and upper abdominal pain was admitted into hospital. Because of the clinical picture, the symptomatology and the leukocytosis a diagnosis of acute appendicitis was made and the patient underwent appendicectomy according to Mc Burney. At laparotomy some cc of purulent fluid were sucked and a cystic mass that contained clear fluid was revealed. In consequence of the incidental diagnosis a following middle laparotomy was made with a careful surgical excision of the mass and of the appendix. Macroscopically the lesion was identified like a neoplastic mass 25 centimeters in diameter, with a multicystic and fibrous-adipose aspect, with cysts 5 centimeters in diameter. The cystic spaces were lined by a layer of eptelial cells which presented positive reaction for cytokeratin and EMA, whereas endothelium markers were absent. The ultrastructural, morphological and immunohistochemical findings were diagnostic of a benign multicystic mesothelioma.


Asunto(s)
Mesotelioma/diagnóstico , Neoplasias Peritoneales/diagnóstico , Dolor Abdominal/etiología , Enfermedad Aguda , Adulto , Apendicitis/diagnóstico , Diagnóstico Diferencial , Estudios de Seguimiento , Humanos , Inmunohistoquímica , Masculino , Mesotelioma/patología , Mesotelioma/cirugía , Neoplasias Peritoneales/patología , Neoplasias Peritoneales/cirugía , Peritoneo/patología , Factores de Tiempo
19.
Clin J Gastroenterol ; 4(2): 60-3, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26190706

RESUMEN

Celiomesenteric ischemia has an insidious onset and the non-specific symptoms are often misdiagnosed as cholecystitis or peptic ulcer disease with a consequential delay between the onset of symptoms and radiological evidence of vascular occlusive disease. A elderly man was hospitalized after a 2-3 week history of acute abdominal pain, frequent vomiting, and chronic diarrhea associated with bloody stools. Upper gastrointestinal endoscopy showed a cobblestone gastric pattern with multiple ulcerated areas and the specimens indicated focal full thickness coagulative necrosis of the mucosa. A magnetic resonance angiography (MRA) revealed a widespread and severe atheromatous disease characterized by a hemodynamically significant stenosis of the celiac tripod, pre-occlusive stenosis of the superior mesenteric artery and complete occlusion of the inferior mesenteric artery. MRA is now the best and most accessible noninvasive examination to help establish a diagnosis, providing high-quality three-dimensional images of the celiac axis and mesenteric arteries. However, the various features observed in this case such as the clinical history, the presence of a cobblestone pattern with multiple ulcerated areas in the stomach, the coagulative-type necrosis and ischemic atrophy of the adjacent mucosa were considered diagnostic of gastric ischemia.

20.
J Card Surg ; 22(2): 139-41, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17338749

RESUMEN

BACKGROUND: The Ultracision Harmonic Scalpel is associated with several advantages in radial artery (RA) harvesting. It allows fewer hemostatic clips to close the collateral branches, less thermal injury of the conduit, and reduced time of harvesting in comparison with the conventional RA harvesting technique with electrocautery and hemostatic clips. We recently started open RA harvesting with the harmonic shears (HSH). In this study, we aimed at evaluating the feasibility of this simplified ultrasonically activated harvesting technique, and report the results of RA harvesting with HSH. METHODS: The RA harvesting with HSH was performed in 20 patients operated on for myocardial revascularization from July 2004 to December 2005. RESULTS: The harvest of the RA was completed in little time, without any complication. Neither bleeding from the collateral branches nor spasm alongside the entire length of the RA was observed. No bleeding occurred from the muscles of the forearm. CONCLUSION: This technique of RA harvesting with HSH is impressive in terms of short time of harvest, complete absence of clips for the collateral branches, and no thermal injury of the conduit.


Asunto(s)
Arteria Radial/trasplante , Recolección de Tejidos y Órganos/instrumentación , Terapia por Ultrasonido , Anciano , Estenosis Coronaria/fisiopatología , Estenosis Coronaria/cirugía , Estudios de Factibilidad , Femenino , Antebrazo/irrigación sanguínea , Hemostasis Quirúrgica/instrumentación , Hemostasis Quirúrgica/métodos , Humanos , Anastomosis Interna Mamario-Coronaria , Masculino , Persona de Mediana Edad , Arteria Radial/fisiopatología , Recolección de Tejidos y Órganos/métodos , Resultado del Tratamiento , Grado de Desobstrucción Vascular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA