Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Knee Surg Sports Traumatol Arthrosc ; 31(4): 1247-1266, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34601628

RESUMEN

PURPOSE: Metallic resurfacing implants have been developed for the treatment of early, small, condylar and trochlear osteoarthritis (OA) lesions. They represent an option for patients who do not fulfill the criteria for unicompartmental knee arthroplasty (UKA) or total knee arthroplasty (TKA) or are too old for biological treatment. Although clinical evidence has been collected for different resurfacing types, the in vivo post-operative knee kinematics remain unknown. The present study aims to analyze the knee kinematics in subjects with patient-specific episealer implants. This study hypothesized that patient-specific resurfacing implants would lead to knee kinematics close to healthy knees, resulting in medial pivot and a high degree of femoral rollback during flexion. METHODS: Retrospective study design. Fluoroscopic analysis during unloaded flexion-extension and loaded lunge was conducted at > 12 months post-surgery in ten episealer knees, and compared to ten healthy knees. Pre- and post-operative clinical data of the episealer knees were collected using a visual analog scale (VAS), the EQ 5d Health, and the Knee Injury and Osteoarthritis Outcome Score (KOOS) questionnaires. RESULTS: A consistent medial pivot was observed in both episealer and healthy knees. Non-significant differences were found in the unloaded (p = 0.15) and loaded (p = 0.51) activities. Although lateral rollback was observed in both groups, it was significantly higher for the episealer knees in both the unloaded (p = 0.02) and loaded (p = 0.01) activities. Coupled axial rotation was significantly higher in the unloaded (p = 0.001) but not in the loaded (p = 0.06) activity in the episealer knees. Improved scores were observed at 1-year post-surgery in the episealer subjects for the VAS (p = 0.001), KOOS (p = 0.001) and EQ Health (p = 0.004). CONCLUSION: At 12 month follow-up, a clear physiological knee kinematics pattern of medial pivot, lateral femoral rollback and coupled axial external femoral rotation during flexion was observed in patients treated with an episealer resurfacing procedure. However, higher femoral rollback and axial external rotation in comparison to healthy knees was observed, suggesting possible post-operative muscle weakness and consequent insufficient stabilization at high flexion.


Asunto(s)
Prótesis de la Rodilla , Osteoartritis de la Rodilla , Humanos , Estudios Retrospectivos , Proyectos Piloto , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/fisiología , Osteoartritis de la Rodilla/cirugía , Rango del Movimiento Articular/fisiología , Fenómenos Biomecánicos
2.
Knee Surg Sports Traumatol Arthrosc ; 26(6): 1645-1655, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28656456

RESUMEN

PURPOSE: As the aims of changes in total knee arthroplasty (TKA) designs are to reinstate more natural kinematics, the current study evaluated the in vivo kinematics in patients who underwent a cruciate retaining gradually changing femoral radius ("G-CURVE") against a cruciate retaining conventional changing femoral radius ("J-CURVE") geometry TKA design. The hypothesis of the study is that the G-CURVE design would allow a substantial increase in the femoral rollback compared to the J-CURVE design. METHODS: Retrospective study design. Thirty patients were included (G-CURVE, n = 20; J-CURVE, n = 10). Single-plane fluoroscopic analysis and marker-based motion capture gait analysis was performed to analyse dynamic tibiofemoral motion during weight-bearing and unloaded activities at 24 month after index surgery. RESULTS: The analysis of the medial and lateral points on the tibia plateau during the unloaded flexion-extension and the weight-bearing lunge activities revealed a significant difference in femoral rollback in G-CURVE TKA above 60° (p = 0.001) and 30° (p = 0.02) of knee flexion, respectively. Moreover, the lateral condyle of the G-CURVE showed a higher extent of femoral rollback while the lateral condyle of the J-CURVE rolled forward. CONCLUSION: At 2 years post-operative, the G-CURVE TKA showed significant differences in femoro-tibial translation in comparison with the J-CURVE system, in vivo. The G-CURVE resulted in an increased lateral rollback and simultaneously in an elimination of the paradoxical medial roll-forward present in the J-CURVE design. Moreover, knee kinematics analysis showed significant differences between unloaded and weight-bearing conditions revealing the impact of load and muscle force. The analysis conducted in this study contributes to further understand the principal movement characteristics in widely used older designs in comparison with recently developed concepts to get a better overview on their potential benefits on in vivo kinematics. LEVEL OF EVIDENCE: III.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/instrumentación , Fémur/cirugía , Articulación de la Rodilla/cirugía , Osteoartritis de la Rodilla/cirugía , Tibia/cirugía , Anciano , Artroplastia de Reemplazo de Rodilla/métodos , Fenómenos Biomecánicos , Femenino , Fémur/diagnóstico por imagen , Fémur/fisiopatología , Fluoroscopía , Humanos , Imagenología Tridimensional , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/fisiopatología , Prótesis de la Rodilla , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/diagnóstico por imagen , Osteoartritis de la Rodilla/fisiopatología , Diseño de Prótesis , Rango del Movimiento Articular/fisiología , Estudios Retrospectivos , Análisis y Desempeño de Tareas , Tibia/diagnóstico por imagen , Tibia/fisiopatología
3.
Front Bioeng Biotechnol ; 12: 1322136, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38352697

RESUMEN

Purpose: Passive tibiofemoral anterior-posterior (AP) laxity has been extensively investigated after posterior cruciate ligament (PCL) single-bundle reconstruction. However, the PCL also plays an important role in providing rotational stability in the knee. Little is known in relation to the effects of PCL single-bundle reconstruction on passive tibiofemoral rotational laxity. Gait biomechanics after PCL reconstruction are even less understood. The aim of this study was a comprehensive prospective biomechanical in vivo analysis of the effect of PCL single-bundle reconstruction on passive tibiofemoral rotational laxity, passive anterior-posterior laxity, and gait pattern. Methods: Eight patients undergoing PCL single-bundle reconstruction (seven male, one female, mean age 35.6 ± 6.6 years, BMI 28.0 ± 3.6 kg/m2) were analyzed preoperatively and 6 months postoperatively. Three of the eight patients received additional posterolateral corner (PLC) reconstruction. Conventional stress radiography was used to evaluate passive translational tibiofemoral laxity. A previously established rotometer device with a C-arm fluoroscope was used to assess passive tibiofemoral rotational laxity. Functional gait analysis was used to examine knee kinematics during level walking. Results: The mean side-to-side difference (SSD) in passive posterior translation was significantly reduced postoperatively (12.1 ± 4.4 mm vs. 4.3 ± 1.8 mm; p < 0.01). A significant reduction in passive tibiofemoral rotational laxity at 90° knee flexion was observed postoperatively (27.8° ± 7.0° vs. 19.9° ± 7.5°; p = 0.02). The range of AP tibiofemoral motion during level walking was significantly reduced in the reconstructed knees when compared to the contralateral knees at 6-month follow-up (16.6 ± 2.4 mm vs. 13.5 ± 1.6 mm; p < 0.01). Conclusion: PCL single-bundle reconstruction with optional PLC reconstruction reduces increased passive tibiofemoral translational and rotational laxity in PCL insufficient knees. However, increased passive tibiofemoral translational laxity could not be fully restored and patients showed altered knee kinematics with a significantly reduced range of tibiofemoral AP translation during level walking at 6-month follow-up. The findings of this study indicate a remaining lack of restoration of biomechanics after PCL single-bundle reconstruction in the active and passive state, which could be a possible cause for joint degeneration after PCL single-bundle reconstruction.

4.
Front Bioeng Biotechnol ; 12: 1352794, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38686117

RESUMEN

As a solution to restore knee function and reduce pain, the demand for Total Knee Arthroplasty (TKA) has dramatically increased in recent decades. The high rates of dissatisfaction and revision makes it crucially important to understand the relationships between surgical factors and post-surgery knee performance. Tibial implant alignment in the sagittal plane (i.e., posterior tibia slope, PTS) is thought to play a key role in quadriceps muscle forces and contact conditions of the joint, but the underlying mechanisms and potential consequences are poorly understood. To address this biomechanical challenge, we developed a subject-specific musculoskeletal model based on the bone anatomy and precise implantation data provided within the CAMS-Knee datasets. Using the novel COMAK algorithm that concurrently optimizes joint kinematics, together with contact mechanics, and muscle and ligament forces, enabled highly accurate estimations of the knee joint biomechanics (RMSE <0.16 BW of joint contact force) throughout level walking and squatting. Once confirmed for accuracy, this baseline modelling framework was then used to systematically explore the influence of PTS on knee joint biomechanics. Our results indicate that PTS can greatly influence tibio-femoral translations (mainly in the anterior-posterior direction), while also suggesting an elevated risk of patellar mal-tracking and instability. Importantly, however, an increased PTS was found to reduce the maximum tibio-femoral contact force and improve efficiency of the quadriceps muscles, while also reducing the patellofemoral contact force (by approximately 1.5% for each additional degree of PTS during walking). This study presents valuable findings regarding the impact of PTS variations on the biomechanics of the TKA joint and thereby provides potential guidance for surgically optimizing implant alignment in the sagittal plane, tailored to the implant design and the individual deficits of each patient.

5.
J Biomech ; 151: 111549, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36948000

RESUMEN

Patellar complications frequently limit the success of total knee arthroplasty. In addition to the musculoskeletal forces themselves, patellar tendon elastic properties are essential for driving patellar loading. Elastic properties reported in the literature exhibit high variability and appear to differ according to the methodologies used. Specifically in total knee arthroplasty patients, only limited knowledge exists on in vivo elastic properties and their corresponding loads. For the first time, we report stiffness, Young's modulus, and forces of the patellar tendon, derived from four patients with telemetric total knee arthroplasties using a combined imaging and measurement approach. To achieve this, synchronous in vivo telemetric assessment of tibio-femoral contact forces and fluoroscopic assessment of knee kinematics, along with full body motion capture and ground reaction forces, fed musculoskeletal multi-body models to quantify patellar tendon loading and elongation. Mechanical patellar tendon properties were calculated during a squat and a sit-stand-sit activity, with resulting tendon stiffness and Young's modulus ranging from 511 to 1166 N/mm and 259 to 504 MPa, respectively. During these activities, the patellar tendon force reached peak values between 1.31 and 2.79 bodyweight, reaching levels of just âˆ¼0.5 bodyweight below the tibio-femoral forces. The results of this study provide valuable input data for mechanical simulations of the patellar tendon and the whole resurfaced knee.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Ligamento Rotuliano , Humanos , Fenómenos Biomecánicos , Articulación de la Rodilla , Tendones , Artroplastia de Reemplazo de Rodilla/métodos , Módulo de Elasticidad
6.
Sci Rep ; 12(1): 13232, 2022 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-35918487

RESUMEN

Passive translational tibiofemoral laxity has been extensively examined in posterior cruciate ligament (PCL) insufficient patients and belongs to the standard clinical assessment. However, objective measurements of passive rotational knee laxity, as well as range of tibiofemoral motion during active movements, are both not well understood. None of these are currently quantified in clinical evaluations of patients with PCL insufficiency. The objective of this study was to quantify passive translational and rotational knee laxity as well as range of anterior-posterior and rotational tibiofemoral motion during level walking in a PCL insufficient patient cohort as a basis for any later clinical evaluation and therapy. The laxity of 9 patient knees with isolated PCL insufficiency or additionally posterolateral corner (PLC) insufficiency (8 males, 1 female, age 36.78 ± 7.46 years) were analysed and compared to the contralateral (CL) knees. A rotometer device with a C-arm fluoroscope was used to assess the passive tibiofemoral rotational laxity while stress radiography was used to evaluate passive translational tibiofemoral laxity. Functional gait analysis was used to examine the range of anterior-posterior and rotational tibiofemoral motion during level walking. Passive translational laxity was significantly increased in PCL insufficient knees in comparison to the CL sides (15.5 ± 5.9 mm vs. 3.7 ± 1.9 mm, p < 0.01). Also, passive rotational laxity was significantly higher compared to the CL knees (26.1 ± 8.2° vs. 20.6 ± 5.6° at 90° knee flexion, p < 0.01; 19.0 ± 6.9° vs. 15.5 ± 5.9° at 60° knee flexion, p = 0.04). No significant differences were observed for the rotational (16.3 ± 3.7° vs. 15.2 ± 3.6°, p = 0.43) and translational (17.0 ± 5.4 mm vs. 16.1 ± 2.8 mm, p = 0.55) range of anterior-posterior and rotational tibiofemoral motion during level walking conditions for PCL insufficient knees compared to CL knees respectively. The present study illustrates that patients with PCL insufficiency show a substantial increased passive tibiofemoral laxity, not only in tibiofemoral translation but also in tibiofemoral rotation. Our data indicate that this increased passive multiplanar knee joint laxity can be widely compensated during level walking. Further studies should investigate progressive changes in knee joint laxity and kinematics post PCL injury and reconstruction to judge the individual need for therapy and effects of physiotherapy such as quadriceps force training on gait patterns in PCL insufficient patients.


Asunto(s)
Inestabilidad de la Articulación , Ligamento Cruzado Posterior , Adulto , Fenómenos Biomecánicos , Femenino , Humanos , Articulación de la Rodilla , Masculino , Rango del Movimiento Articular , Rotación , Tibia/cirugía , Caminata
7.
J Biomech ; 141: 111171, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35803037

RESUMEN

Knowledge of both tibio-femoral kinematics and kinetics is necessary for fully understanding knee joint biomechanics, guiding implant design and testing, and driving and validating computational models. In 2017, the CAMS-Knee datasets were presented, containing synchronized in vivo implant kinematics measured using a moving fluoroscope and tibio-femoral contact loads measured using instrumented implants from six subjects. However, to date, no representative summary of kinematics and kinetics obtained from measurements at the joint level of the same cohort of subjects exists. In this study, we present the CAMS-Knee standardized subject "Stan", whose reference data include tibio-femoral kinematics and loading scenarios from all six subjects for level and downhill walking, stair descent, squat and sit-to-stand-to-sit. Using the peak-preserving averaging method by Bergmann and co-workers, we derived scenarios for generally high (CAMS-HIGH100), peak, and extreme loading. The CAMS-HIGH100 axial forces reached peaks between 3022 and 3856 N (3.08-3.93 body weight) for the five investigated activities. Anterior-posterior forces were about a factor of ten lower. The axial moment around the tibia was highest for level walking and squatting with peaks of 9.4 Nm and 10.5 Nm acting externally. Internal tibial rotations of up to 8.4° were observed during squat and sitting, while the walking activities showed approximately half the internal rotation. The CAMS-HIGH100 loads were comparable to Bergmann and co-workers', but have the additional benefit of synchronized kinematics. Stan's loads are +11 to +56% higher than the ISO 14243 wear testing standard loads, while the kinematics exhibit markedly different curve shapes. Along with the original CAMS-Knee datasets, Stan's data can be requested at cams-knee.orthoload.com.


Asunto(s)
Distinciones y Premios , Prótesis de la Rodilla , Fenómenos Biomecánicos , Fémur , Humanos , Articulación de la Rodilla , Tibia
8.
J Bone Joint Surg Am ; 103(2): 146-154, 2021 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-33060427

RESUMEN

BACKGROUND: The apparently physiological kinematics of the bicruciate-stabilized total knee arthroplasty (BCS TKA) systems have been attributed to the anterior and posterior post-cam mechanism. Although comparisons between TKA designs with either a retained or a sacrificed cruciate ligament have been conducted, we are not aware of any analyses of 2 implants with identical bearing geometry but different cruciate-ligament strategies under equal loading conditions. Knowledge about the kinematic effect of the different cruciate ligament strategies would potentially be valuable to facilitate preoperative planning and decision-making with regard to selecting the most appropriate implant for a patient. METHODS: This retrospective study included 20 patients: 10 treated with a BCS and 10 treated with a cruciate retaining (CR) TKA. Fluoroscopic analyses during high-flexion activities (unloaded flexion-extension and loaded lunge) were conducted at 24 months postsurgery. All patients completed the Knee Society Score, Forgotten Joint Score, and High-Flexion Knee Score questionnaires preoperatively and postoperatively. RESULTS: The BCS cohort showed greater femoral lateral rollback as well as a medial pivot in both activities. In contrast, the CR cohort showed a significant increase in anterior translation on the medial compartment as well as almost absent femoral lateral rollback. Higher clinical scores were observed in the BCS cohort. CONCLUSIONS: At 24 months postsurgery, despite equal bearing geometry, retention of the posterior cruciate ligament in the CR cohort apparently was insufficient to reduce anterior shift. The BCS cohort showed expected knee joint kinematics; however, the kinematics in this cohort could eventually benefit from a smooth transition between the interchanging surfaces. Further investigation should be focused on the surgical technique and its interaction with the TKA design. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Traumatismos de la Rodilla/fisiopatología , Articulación de la Rodilla/fisiopatología , Osteoartritis de la Rodilla/cirugía , Ligamento Cruzado Posterior/cirugía , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Rodilla/efectos adversos , Fenómenos Biomecánicos , Femenino , Humanos , Traumatismos de la Rodilla/cirugía , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla/efectos adversos , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/fisiopatología , Ensayos Clínicos Controlados Aleatorios como Asunto , Estudios Retrospectivos
9.
Front Bioeng Biotechnol ; 9: 754715, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34820363

RESUMEN

Some approaches in total knee arthroplasty aim for an oblique joint line to achieve an even medio-lateral load distribution across the condyles during the stance phase of gait. While there is much focus on the angulation of the joint line in static frontal radiographs, precise knowledge of the associated dynamic joint line orientation and the internal joint loading is limited. The aim of this study was to analyze how static alignment in frontal radiographs relates to dynamic alignment and load distribution, based on direct measurements of the internal joint loading and kinematics. A unique and novel combination of telemetrically measured in vivo knee joint loading and simultaneous internal joint kinematics derived from mobile fluoroscopy ("CAMS-Knee dataset") was employed to access the dynamic alignment and internal joint loading in 6 TKA patients during level walking. Static alignment was measured in standard frontal postoperative radiographs while external adduction moments were computed based on ground reaction forces. Both static and dynamic parameters were analyzed to identify correlations using linear and non-linear regression. At peak loading during gait, the joint line was tilted laterally by 4°-7° compared to the static joint line in most patients. This dynamic joint line tilt did not show a strong correlation with the medial force (R 2: 0.17) or with the mediolateral force distribution (pseudo R 2: 0.19). However, the external adduction moment showed a strong correlation with the medial force (R 2: 0.85) and with the mediolateral force distribution (pseudo R 2: 0.78). Alignment measured in static radiographs has only limited predictive power for dynamic kinematics and loading, and even the dynamic orientation of the joint line is not an important factor for the medio-lateral knee load distribution. Preventive and rehabilitative measures should focus on the external knee adduction moment based on the vertical and horizontal components of the ground reaction forces.

10.
Sci Rep ; 10(1): 759, 2020 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-31937883

RESUMEN

An amendment to this paper has been published and can be accessed via a link at the top of the paper.

11.
Sci Rep ; 9(1): 9148, 2019 06 24.
Artículo en Inglés | MEDLINE | ID: mdl-31235890

RESUMEN

The knee joint center of rotation is altered in the absence of the anterior cruciate ligament, which leads to substantially higher variance in kinematic patterns. To overcome this, total knee arthroplasty (TKA) designs with a high congruency in the lateral compartment have been proposed. The purpose of this study was to analyze the influence of a lateral pivot TKA-design on in-vivo knee joint kinematics. Tibiofemoral motion was retrospectively addressed in 10 patients during unloaded flexion-extension and loaded lunge using single plane fluoroscopy. During the unloaded flexion-extension movement, the lateral condyle remained almost stationary with little rollback at maximum flexion. The medial condyle exhibited anterior translation during the whole flexion cycle. During the loaded lunge movement, a higher degree of rollback compared to the unloaded activity was observed on the lateral condyle, whereas the medial condyle remained almost stationary. The results showed a clear lateral pivot during the unloaded activity, reflective of the implant's geometric characteristics, and a change to a medial pivot and a higher lateral rollback during the weight-bearing conditions, revealing the impact of load and muscle force. It remains unclear if the kinematics with a lateral TKA design could be considered as physiological, due to the limited knowledge available on native knee joint kinematics.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Articulación de la Rodilla/fisiología , Articulación de la Rodilla/cirugía , Rango del Movimiento Articular , Adulto , Fenómenos Biomecánicos , Femenino , Humanos , Masculino , Estudios Retrospectivos , Soporte de Peso
12.
PLoS One ; 13(2): e0192225, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29401510

RESUMEN

Mechanical and kinematical aligning techniques are the usual positioning methods during total knee arthroplasty. However, alteration of the physiological joint line and unbalanced medio-lateral load distribution are considered disadvantages in the mechanical and kinematical techniques, respectively. The aim of this study was to analyse the influence of the joint line on the strain and stress distributions in an implanted knee and their sensitivity to rotational mal-alignment. Finite element calculations were conducted to analyse the stresses in the PE-Inlay and the mechanical strains at the bone side of the tibia component-tibia bone interface during normal positioning of the components and internal and external mal-rotation of the tibial component. Two designs were included, a horizontal and a physiological implant. The loading conditions are based on internal knee joint loads during walking. A medialization of the stresses on the PE-Inlay was observed in the physiological implant in a normal position, accompanied by higher stresses in the mal-rotated positions. Within the tibia component-tibia bone interface, similar strain distributions were observed in both implant geometries in the normal position. However, a medialization of the strains was observed in the physiological implant in both mal-rotated conditions with greater bone volume affected by higher strains. Although evident changes due to mal-rotation were observed, the stresses do not suggest a local plastic deformation of the PE-Inlay. The strains values within most of the tibia component-tibia bone interface were in the physiological strain zone and no significant bone changes would be expected. The physiological cut on the articular aspect showed no detrimental effect compared to the horizontal implant.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Análisis de Elementos Finitos , Humanos , Estrés Mecánico
13.
PLoS One ; 11(7): e0159600, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27467744

RESUMEN

While the anterior cruciate ligament (ACL) is considered one of the most important ligaments for providing knee joint stability, its influence on rotational laxity is not fully understood and its role in resisting rotation at different flexion angles in vivo remains unknown. In this prospective study, we investigated the relationship between in vivo passive axial rotational laxity and knee flexion angle, as well as how they were altered with ACL injury and reconstruction. A rotometer device was developed to assess knee joint rotational laxity under controlled passive testing. An axial torque of ±2.5Nm was applied to the knee while synchronised fluoroscopic images of the tibia and femur allowed axial rotation of the bones to be accurately determined. Passive rotational laxity tests were completed in 9 patients with an untreated ACL injury and compared to measurements at 3 and 12 months after anatomical single bundle ACL reconstruction, as well as to the contralateral controls. Significant differences in rotational laxity were found between the injured and the healthy contralateral knees with internal rotation values of 8.7°±4.0° and 3.7°±1.4° (p = 0.003) at 30° of flexion and 9.3°±2.6° and 4.0°±2.0° (p = 0.001) at 90° respectively. After 3 months, the rotational laxity remained similar to the injured condition, and significantly different to the healthy knees. However, after 12 months, a considerable reduction of rotational laxity was observed towards the levels of the contralateral controls. The significantly greater laxity observed at both knee flexion angles after 3 months (but not at 12 months), suggests an initial lack of post-operative rotational stability, possibly due to reduced mechanical properties or fixation stability of the graft tissue. After 12 months, reduced levels of rotational laxity compared with the injured and 3 month conditions, both internally and externally, suggests progressive rotational stability of the reconstruction with time.


Asunto(s)
Reconstrucción del Ligamento Cruzado Anterior/métodos , Fémur/cirugía , Tibia/cirugía , Adulto , Femenino , Fémur/fisiopatología , Humanos , Inestabilidad de la Articulación , Masculino , Tibia/fisiopatología , Adulto Joven
14.
Am J Sports Med ; 41(5): 1051-7, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23492824

RESUMEN

BACKGROUND: Although instability of the knee joint is known to modify gait patterns, the amount that patients compensate for joint laxity during active movements remains unknown. PURPOSE: By developing a novel technique to allow the assessment of tibiofemoral kinematics, this study aimed to elucidate the role of passive joint laxity on active tibiofemoral kinematics during walking. STUDY DESIGN: Controlled laboratory study. METHODS: Using motion capture, together with combinations of advanced techniques for assessing skeletal kinematics (including the symmetrical axis of rotation approach [SARA], symmetrical center of rotation estimation [SCoRE], and optimal common shape technique [OCST]), a novel noninvasive approach to evaluate dynamic tibiofemoral motion was demonstrated as both reproducible and repeatable. Passive and active anterior-posterior translations of the tibiofemoral joint were then examined in 13 patients with anterior cruciate ligament (ACL) ruptures that were confirmed by magnetic resonance imaging and compared with those in their healthy contralateral limbs. RESULTS: Passive tibial anterior translation was significantly greater in the ACL-ruptured knees than in the contralateral healthy controls. However, the femora of the ACL-ruptured knees generally remained more posterior (~3 mm) relative to the tibia within a gait cycle of walking compared with the healthy limbs. Surprisingly, the mean range of tibiofemoral anterior-posterior translation over an entire gait cycle was significantly lower in ACL-ruptured knees than in the healthy joints (P = .026). A positive correlation was detected between passive laxity and active joint mobility, but with a consistent reduction in the range of tibiofemoral anterior-posterior translation of approximately 3 mm in the ACL-deficient knees. CONCLUSION: It seems that either active stabilization of tibiofemoral kinematics or anterior subluxation of the tibia reduces joint translation in lax knees. This implies that either a muscular overcompensation mechanism or a physical limitation due to secondary passive stabilizers occurs within the joint and thus produces a situation that has a reduced range of active motion compared with knees with physiological stability. CLINICAL RELEVANCE: The reduced range of active tibiofemoral translation suggests overloading of the passive structures in passively lax knees, either through excessive muscular action or joint subluxation, and could provide a plausible mechanism for explaining posttraumatic degeneration of cartilage in the joint.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Ligamento Cruzado Anterior/fisiopatología , Marcha/fisiología , Inestabilidad de la Articulación/fisiopatología , Articulación de la Rodilla/fisiopatología , Rango del Movimiento Articular , Adaptación Fisiológica , Adulto , Análisis de Varianza , Fenómenos Biomecánicos , Femenino , Fémur/fisiopatología , Humanos , Inestabilidad de la Articulación/etiología , Imagen por Resonancia Magnética , Masculino , Rotura/complicaciones , Rotura/fisiopatología , Tibia/fisiopatología , Caminata/fisiología , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA