Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 35(6): 1101-1111, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38519418

RESUMEN

INTRODUCTION: Limited data exist on pulsed-field ablation (PFA) in patients with persistent atrial fibrillation (PeAF) undergoing left atrial posterior wall isolation (LAPWI). METHODS: The Advanced TecHnologies For SuccEssful AblatioN of AF in Clinical Practice (ATHENA) prospective registry included consecutive patients referred for PeAF catheter ablation at 9 Italian centers, treated with the FARAPULSETM-PFA system. The primary efficacy and safety study endpoints were the acute LAPWI rate, freedom from arrhythmic recurrences and the incidence of major periprocedural complications. Patients undergoing pulmonary vein isolation (PVI) alone, PWI + LAPWI and redo procedures were compared. RESULTS: Among 249 patients, 21.7% had long-standing PeAF, 79.5% were male; mean age was 63 ± 9 years. LAPWI was performed in 57.6% of cases, with 15.3% being redo procedures. Median skin-to-skin times (PVI-only 68 [60-90] vs. PVI + LAPWI 70 [59-88] mins) did not differ between groups. 45.8% LAPWI cases were approached with a 3D-mapping system, and 37.3% with intracardiac echocardiography. LAPWI was achieved in all patients by means of PFA alone, in 88.8% cases at first pass. LAPWI was validated either by an Ultrahigh-density mapping system or by recording electrical activity + pacing maneuvers. No major complications occurred, while 2.4% minor complications were detected. During a median follow-up of 273 [191-379] days, 41 patients (16.5%) experienced an arrhythmic recurrence after the 90-day blanking period, with a mean time to recurrence of 223 ± 100 days and no differences among ablation strategies. CONCLUSION: LAPWI with PFA demonstrates feasibility, rapidity, and safety in real-world practice, offering a viable alternative for PeAF patients. LAPWI is achievable even with a fluoroscopy-only method and does not significantly extend overall procedural times.


Asunto(s)
Potenciales de Acción , Fibrilación Atrial , Ablación por Catéter , Frecuencia Cardíaca , Venas Pulmonares , Recurrencia , Sistema de Registros , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Masculino , Femenino , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología , Persona de Mediana Edad , Ablación por Catéter/efectos adversos , Anciano , Estudios Prospectivos , Factores de Tiempo , Italia , Factores de Riesgo , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/cirugía , Resultado del Tratamiento , Supervivencia sin Progresión
2.
Artículo en Inglés | MEDLINE | ID: mdl-37708328

RESUMEN

Pulmonary vein isolation and left atrial posterior wall ablation using the Farapulse system, followed by left atrial appendage occlusion, have been achieved as single combined procedure to treat long-standing persistent atrial fibrillation in a patient at high hemorrhagic risk.

3.
Pacing Clin Electrophysiol ; 46(11): 1302-1309, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37846769

RESUMEN

INTRODUCTION: Recently, a new cryoballoon (CB) technology (POLARx; Boston Scientific) has come onto the market. Preliminary data have shown that its acute safety and efficacy are similar to those of the first-generation CB. The aim of this study was to assess the medium-term outcome of pulmonary vein isolation (PVI) with the POLARxTM CB in a large multicenter registry. METHODS: We prospectively collected data on 125 consecutive patients with paroxysmal atrial fibrillation (AF) who underwent PVI by means of a novel CB system. Two cases of transient phrenic nerve palsy occurred, with full recovery in the 48h post procedure; no major procedure-related adverse events were reported. During the 90-day blanking period, 4 (3.2%) patients experienced an early recurrence. After the blanking period, over a mean follow-up of 411 ± 62 days, 19 patients (15.2%) suffered an AF/atrial tachycardia (AT) recurrence. The 1-year freedom from AF/AT recurrence was 86.4% (n = 17): 10 (8%) patients had an AF recurrence, 6 (4.8%) had an AT occurrence and 1 (0.8%) suffered both events. Patients with AF/AT recurrences had both a shorter deflation time and total deflation time. Moreover, CB ablations with measured TTI < 90 s and TTI < 60 s were more frequent in patients without AF/AT recurrence (88.5% and 77.4%, respectively) than in those who experienced at least one AF/AT recurrence (67.5% and 55.0%, p = .001 and p = .005, respectively). CONCLUSION: The novel POLARx cryo-balloon system is safe and effective for PV isolation, displaying a 1-year freedom from atrial arrhythmia recurrence of 86.4%, which is in line to that reported with AFA-Pro CB or RF ablation. CLINICAL TRIAL REGISTRATION: Catheter Ablation of Arrhythmias with a High-Density Mapping System in Real-World Practice (CHARISMA). URL: http://clinicaltrials.gov/ Identifier: NCT03793998. Registration date: January 4, 2019.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Venas Pulmonares/cirugía , Resultado del Tratamiento , Criocirugía/métodos , Italia/epidemiología , Sistema de Registros , Ablación por Catéter/métodos , Recurrencia
4.
Eur Heart J Suppl ; 24(Suppl C): C243-C247, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35602257

RESUMEN

The rate of post-vaccine myocarditis is being studied from the beginning of the massive vaccination campaign against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Although a direct cause-effect relationship has been described, in most cases, the vaccine pathophysiological role is doubtful. Moreover, it is not quite as clear as having had a previous myocarditis could be a risk factor for a post-vaccine disease relapse. A 27-year-old man presented to the emergency department for palpitations and pericardial chest pain radiated to the upper left limb, on the 4th day after the third dose of BNT162b2 vaccine. He experienced a previous myocarditis 3 years before, with full recovery and no other comorbidities. Electrocardiogram showed normal atrioventricular conduction, incomplete right bundle branch block, and diffuse ST-segment elevation. A cardiac echo showed lateral wall hypokinesis with preserved ejection fraction. Troponin-T was elevated (160 ng/L), chest X-ray was normal, and the SARS-CoV-2 molecular buffer was negative. High-dose anti-inflammatory therapy with ibuprofen and colchicine was started; in the 3rd day high-sensitivity Troponin I reached a peak of 23000 ng/L. No heart failure or arrhythmias were observed. A cardiac magnetic resonance was performed showing normal biventricular systolic function and abnormal tissue characterization suggestive for acute non-ischaemic myocardial injury (increased native T1 and T2 values, increased signal intensity at T2-weighted images and late gadolinium enhancement, all findings with matched subepicardial distribution) at the level of mid to apical septal, anterior, and anterolateral walls. A left ventricular electroanatomic voltage mapping was negative (both unipolar and bipolar), while the endomyocardial biopsy showed a picture consistent with active myocarditis. The patient was discharged in good clinical condition, on bisoprolol 1.25 mg, ramipril 2.5 mg, ibuprofen 600 mg three times a day, colchicine 0.5 mg twice a day. We presented the case of a young man with history of previous myocarditis, admitted with a non-complicated acute myopericarditis relapse occurred 4 days after SARS-CoV-2 vaccination (3rd dose). Despite the observed very low incidence of cardiac complications following BNT162b2 administration, and the lack of a clear proof of a direct cause-effect relationship, we think that in our patient this link can be more than likely. In the probable need for additional SARS-CoV-2 vaccine doses in the next future, studies addressing the risk-benefit balance of this subset of patient are warranted. We described a multidisciplinary management of a case of myocarditis recurrence after the third dose of SARS-CoV-2 BNT162b2 vaccine.

5.
Medicina (Kaunas) ; 59(1)2022 Dec 28.
Artículo en Inglés | MEDLINE | ID: mdl-36676690

RESUMEN

Background. Data on leadless pacemaker (LPM) implantation in an emergency setting are currently lacking. Objective. We aimed to investigate the feasibility of LPM implantation for emergency bradyarrhythmia, in patients referred for urgent PM implantation, in a large, multicenter, real-world cohort of LPM recipients. Methods. Two cohorts of LPM patients, stratified according to the LPM implantation scenario (patients admitted from the emergency department (ED+) vs. elective patients (ED−)) were retrieved from the iLEAPER registry. The primary outcome of the study was a comparison of the peri-procedural complications between the groups. The rates of peri-procedural characteristics (overall procedural and fluoroscopic duration) were deemed secondary outcomes. Results. A total of 1154 patients were enrolled in this project, with patients implanted due to an urgent bradyarrhythmia (ED+) representing 6.2% of the entire cohort. Slow atrial fibrillation and complete + advanced atrioventricular blocks were more frequent in the ED+ cohort (76.3% for ED+ vs. 49.7% for ED−, p = 0.025; 37.5% vs. 27.3%, p = 0.027, respectively). The overall procedural times were longer in the ED+ cohort (60 (45−80) mins vs. 50 (40−65) mins, p < 0.001), showing higher rates of temporary pacing (94.4% for ED+ vs. 28.9% for ED−, p < 0.001). Emergency LPM implantation was not correlated with an increase in the rate of major complications compared to the control group (6.9% ED+ vs. 4.2% ED−, p = 0.244). Conclusion. LPM implantation is a feasible procedure for the treatment of severe bradyarrhythmia in an urgent setting. Urgent LPM implantation was not correlated with an increase in the rate of major complications compared to the control group, but it was associated with longer procedural times.


Asunto(s)
Fibrilación Atrial , Marcapaso Artificial , Humanos , Bradicardia/terapia , Fibrilación Atrial/terapia , Resultado del Tratamiento
6.
J Cardiovasc Electrophysiol ; 32(3): 588-594, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33537996

RESUMEN

INTRODUCTION: Catheter ablation is superior to drugs regarding atrial fibrillation (AF) recurrence, symptoms improvement, and mortality reduction in heart failure. POLARx™ is a novel cryoballoon, with technical improvements seeking to improve outcomes. So far, its clinical evidence is restricted to a case report. METHODS: To compare the POLARx™ cryoballoon procedural safety and efficacy to the already established Arctic Front Advance PRO™ (AFAP) in a single-center cohort study, consecutive patients undergoing AF cryoablation with the POLARx™ were enrolled. Data were prospectively gathered. POLARx™ patients were compared with a historical cohort of patients submitted to AF cryoablation with the AFAP. RESULTS: Seventy patients were analyzed, 20 in POLARx™, and 50 in the AFAP group. They all underwent first-time pulmonary vein isolation, 77% were male, 94% had paroxysmal AF, median age was 62.5 years, median CHA2 DS2 -VASc 1, left-atrium size 34 ml/m², and 65% were receiving anticoagulation. The primary end-point, all pulmonary veins isolation, was 100% in both groups. The complication rate was similar (0% POLARx™ vs. 5.7% AFAP, p = .39). The median total procedural time was longer in the POLARx™ group (90 min vs. 60 min, p < .001), but the overall time-to-isolation (TTI; 44.8 s vs. 39 s, p = .253) and ablation time (15 min vs. 13.7 min, p = .122) was similar between POLARx™ and AFAP groups, respectively. Despite equal TTI, the POLARx™ had a lower minimal temperature reached (-57°C vs -47°C, p < .001). CONCLUSION: The novel POLARx™ cryoballoon had similar efficacy and safety compared with the AFAP. It was also associated with longer procedural times, similar TTI, and lower minimum temperature reached.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Estudios de Cohortes , Criocirugía/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Recurrencia , Tecnología , Resultado del Tratamiento
7.
J Cardiovasc Electrophysiol ; 31(12): 3318-3321, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32905654

RESUMEN

Cryoballoon ablation is a recognized and widespread method for pulmonary vein isolation. For many years the impossibility of using it to create additional lines was considered a drawback of this approach. However, recently, the technique was adapted to allow the creation of rooflines, and potentially also inferior lines. In this article, we present the first reported case of a patient submitted to pulmonary vein isolation plus posterior wall isolation using the novel Boston POLAR X™ cryoballoon exclusively. To confirm the quality of the lesions, the patient underwent pre and postablation high-density mapping.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Boston , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Humanos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Resultado del Tratamiento
8.
Pacing Clin Electrophysiol ; 42(5): 553-556, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30515856

RESUMEN

Cryoballoon ablation was developed as a new treatment for pulmonary vein (PV) isolation and has demonstrated high procedural success and comforting long-term clinical outcome. However, some improvements are necessary for real-time visualization of PV signals that appeared important to increase the efficacy and reduce ineffective cryoapplications. We report, for the first time, a cryoablation procedure using the fourth-generation cryoballoon, describing betterment in vein signal recording and acute procedural success.


Asunto(s)
Fibrilación Atrial/cirugía , Criocirugía/instrumentación , Venas Pulmonares/cirugía , Fibrilación Atrial/diagnóstico por imagen , Diseño de Equipo , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Tomografía Computarizada por Rayos X
9.
Pacing Clin Electrophysiol ; 42(7): 890-896, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-31046130

RESUMEN

BACKGROUND: The novel fourth-generation cryoballoon (CB4) potentially allows for enhanced catheter maneuverability and more frequent capture of pulmonary vein (PV) potentials which can be used to monitor real-time PV isolation (PVI). The aim of our study is to compare the acute procedural endpoints between the CB4 and second-generation cryoballoon (CB2). METHODS: A single-center retrospective chart review was used to examine 50 consecutive patients with drug-refractory atrial fibrillation undergoing CB4-based PVI. Procedural data and acute success of these patients were compared to 50 propensity-matched controls who underwent cryoballoon ablation procedure using CB2. RESULTS: Procedures performed with the CB4 showed significant shorter fluoroscopy time (14.8 ± 5.5 vs 18.0 ± 6.5 minutes, P = .04), shorter procedure time (58.3 ± 15.7 vs 65.3 ± 21 minutes, P = .13), and shorter total ablation time (10.8 ± 1.5 vs 13.8 ± 1.9 minutes, P = .42). The real-time PVI visualization rate was 33.3% in the CB2 group and 74.7% in the CB4 group (P < .001). CB4 was correlated to significant increase of acute real-time recordings with regard to all the single PV (left superior PV: 58% vs 84%, P = .02; left inferior PV: 26% vs 71%, P = .001; right superior PV 29% vs 61%, P = .01; and right inferior PV 19% vs 58%, P = .002). CONCLUSION: The CB4 was more often able to capture real-time recordings of PV potentials and the subsequent acute PV isolation.


Asunto(s)
Fibrilación Atrial/cirugía , Oclusión con Balón/instrumentación , Criocirugía/instrumentación , Venas Pulmonares/cirugía , Femenino , Fluoroscopía , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Puntaje de Propensión , Estudios Retrospectivos
10.
Pacing Clin Electrophysiol ; 40(2): 217-218, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27747883

RESUMEN

Cryoballoon ablation is a widely diffuse technology to perform paroxysmal atrial fibrillation ablation. The new generation cryoballoon catheters have been redesigned in order to improve the cooling capability. During cryoballoon ablation, it is not unusual to observe the formation of a contrast dye ice cap on top of the balloon itself. The automated balloon deflation before dissolution of the ice cap may increase the risk of embolization of large ice-mixed-contrast crystals in the systemic circulation. In the case hereby reported, we describe an uneventful embolization of this contrast dye ice cap in the systemic circulation.


Asunto(s)
Fibrilación Atrial/cirugía , Oclusión con Balón/efectos adversos , Medios de Contraste/efectos adversos , Crioterapia/efectos adversos , Embolia/inducido químicamente , Extravasación de Materiales Terapéuticos y Diagnósticos/etiología , Anciano , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Oclusión con Balón/instrumentación , Oclusión con Balón/métodos , Crioterapia/instrumentación , Crioterapia/métodos , Embolia/diagnóstico , Extravasación de Materiales Terapéuticos y Diagnósticos/diagnóstico , Humanos , Masculino , Radiografía Intervencional/efectos adversos , Resultado del Tratamiento
11.
Europace ; 18(11): 1705-1710, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27402623

RESUMEN

AIMS: Pulmonary veins (PVs) isolation is the cornerstone of atrial fibrillation (AF) ablation and can be achieved either by conventional radiofrequency ablation or by cryoenergy. Left atrial appendage (LAA) closure has been proposed as alternative treatment to vitamin K antagonists (VKA). We aimed to evaluate the feasibility of combining cryoballoon (CB) ablation and LAA occlusion in patients with AF and a high thromboembolic risk or contraindication to antithrombotic therapy. METHODS AND RESULTS: Thirty-five patients (28 males, 74 ± 2 years) underwent CB ablation. Left atrial appendage occlusion was carried out by using two occluder devices (Amplatz Cardiac Plug, ACP, St. Jude Medical, MN, USA, in 25 patients; Watchman, Boston Scientific, MA, USA, in 10 patients). Thirty patients (86%) had previous stroke/TIA episodes, 6 patients (17%) had major bleeding while on VKA therapy, and 7 patients (20%) had inherited bleeding disorders. Over the follow-up (24 ± 12 months), atrial arrhythmias recurred in 10 (28%) patients. Thirty patients (86%) had complete sealing; 5 patients (14%) showed a residual flow (<5 mm) at first transoesophageal echocardiography (TEE) check, while at 1-year TEE residual flow was detected in 3 patients. In 13 patients (37%), VKA therapy was immediately discontinued. Six patients (17%) received novel oral anticoagulants treatment and then discontinued 3 months thereafter. No device-related complications or clinical thromboembolic events occurred. CONCLUSION: Combined CB ablation and LAA closure using different devices appears to be feasible in patients with non-valvular AF associated with high risk of stroke or contraindication to antithrombotic treatment.


Asunto(s)
Apéndice Atrial/cirugía , Fibrilación Atrial/terapia , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Dispositivo Oclusor Septal , Anciano , Anticoagulantes/administración & dosificación , Ecocardiografía Tridimensional , Femenino , Estudios de Seguimiento , Hemorragia/etiología , Humanos , Masculino , Estudios Prospectivos , Recurrencia , Accidente Cerebrovascular/etiología , Resultado del Tratamiento , Estados Unidos
13.
J Clin Med ; 13(5)2024 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-38592089

RESUMEN

(1) Background/Objective Balloon-guided catheter ablation (CA) has emerged as an alternative option for atrial fibrillation (AF) management. The recent introduction of a novel-size adjustable second-generation cryoballoon (CB) system offers innovations, but clinical outcomes remain unexplored. This study aims to assess the acute performance of the POLARx FIT™ CB system in AFCA. (2) Methods: Consecutive patients undergoing AF ablation with the POLARx FIT™ CB system in our center were included. The primary outcome was the rate of 31 mm balloon-size utilization, with secondary outcomes including acute pulmonary vein isolation (PVI) rate, periprocedural complications, and in-hospital AF recurrences. (3) Results: Twenty-four patients with a mean age of 59.5 years, predominantly male (87.5%), and exhibiting paroxysmal AF (91.7%) were enrolled. Procedural characteristics demonstrated a high acute success rate (100% PV isolation) with a favorable safety profile. Notably, the 31 mm CB configuration was utilized in 51% of applications, showcasing its adaptability in challenging anatomies. No major complications occurred, with two patients experiencing in-hospital self-limiting AF recurrences. (4) Conclusions: This study represents the first comprehensive assessment of the POLARx FIT™ CB system in AF ablation. While acknowledging the study's limitations, this novel CB emerges as a promising tool, warranting further exploration in larger studies with extended follow-up periods.

14.
JACC Case Rep ; 29(15): 102424, 2024 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-39157554

RESUMEN

We present the first worldwide case of a hybrid surgical-percutaneous procedure involving transvenous lead extraction, concomitant tricuspid valve repair, implantation of an atrioventricular (AV) leadless pacemaker, and extravascular implantable cardioverter-defibrillator placement with suturing of the defibrillation lead to the heart wall. Multiple interventions were necessary as a result of active endocarditis, congenital complete AV block, and ventricular arrhythmia secondary prevention.

15.
JACC Clin Electrophysiol ; 10(7 Pt 2): 1700-1710, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39084744

RESUMEN

BACKGROUND: Hybrid-convergent radiofrequency (RF) ablation targeting pulmonary veins (PVs) and left atrial posterior wall (LAPW) has shown better arrhythmic outcomes than an endocardial-only RF strategy, despite higher rates of complications. Comparisons with extensive pulsed field ablation (PFA) are currently lacking. OBJECTIVES: This study aimed to compare the efficacy and safety of the hybrid-convergent RF vs PFA of PVs and LAPW in long-standing persistent atrial fibrillation (LSPAF). METHODS: Ninety-three consecutive LSPAF patients, treated with 2-step hybrid-convergent RF ablation (hybrid group, n = 49) or with PFA of PVs and LAPW (PFA group, n = 44) were enrolled. Primary efficacy endpoint was defined as any atrial tachyarrhythmias (ATA) recurrence after the 3-month blanking period, over a follow-up time of 12 months. Periprocedural adverse events and late complications during follow-up were deemed primary safety outcomes. RESULTS: The hybrid and PFA groups had similar baseline characteristics; mean age was hybrid 63.8 ± 10.6 years vs PFA 66.0 ± 7.4 years; P = 0.105. PV and LAPW ablation were acutely successful in all patients. Step 1 hybrid-epicardial procedures were longer than PFA (166 [Q1-Q3: 140-205] minutes vs 107.5 [Q1-Q3: 82.5-12] minutes; P < 0.01). At 12-month follow-up, there was no difference in ATA recurrences between groups (hybrid 36.7% vs PFA 40.9%; P = 0.680; log-rank at survival analysis P = 0.539). After adjusting for confounders, a larger left atrial volume and recurrences during the blanking-period were predictors of ATA recurrences after ablation, regardless of procedural technique employed. PFA showed a better safety profile with a lower rate of major periprocedural complications compared with hybrid ablation (12% vs 0%; P = 0.028). CONCLUSIONS: Hybrid-convergent and PFA share comparable arrhythmic outcomes in LSPAF, but hybrid-convergent ablation carries higher periprocedural risks.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/cirugía , Masculino , Persona de Mediana Edad , Femenino , Anciano , Ablación por Catéter/métodos , Ablación por Catéter/efectos adversos , Venas Pulmonares/cirugía , Resultado del Tratamiento , Recurrencia , Atrios Cardíacos/cirugía , Atrios Cardíacos/fisiopatología
16.
Heart Rhythm ; 2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38908459

RESUMEN

BACKGROUND: Studies evaluating the systematic use of cardiac computed tomography (CCT) for the preprocedural assessment of myocardial fibrosis are limited. Their implementation in the electrophysiology workflow has not been extensively described. OBJECTIVE: This study aimed to explore the degree of concordance between CCT and electroanatomic mapping (EAM) for the evaluation of cardiac fibrosis in patients undergoing endo-epicardial ventricular tachycardia (VT) ablation. METHODS: From November 2017 to December 2021, patients undergoing endo-epicardial VT catheter ablation with CCT as the only source of preprocedural scar assessment were prospectively enrolled. After image integration, myocardial fibrosis detected with CCT was compared with low-voltage areas identified by endo-epicardial EAM. Postprocedural VT recurrences of this approach were evaluated after at least 1 year of follow-up. RESULTS: The study enrolled 35 patients (mean age, 60.7 ± 13.2 years; 94.2% male). The most common underlying arrhythmic substrate was dilated cardiomyopathy (48.6%). CCT was employed for contraindications to cardiac magnetic resonance, such as unstable VTs (31.4%) or nonconditional implantable cardioverter-defibrillators (28.6%), but also for patients' and operators' preferences (14.3%-25.7%). Myocardial fibrosis was correctly identified by CCT and EAM, with strong agreement between these techniques both overall (Cohen κ for agreement, 0.933) and in per-segment analysis (κ ranging from 0.796 to 1.0). Ischemic patients showed the best correlation (κ = 1.000), whereas myocarditis showed the worst (κ = 0.750). After a median follow-up of 14 (12-24) months, 1-year freedom from recurrences was achieved in 74.3% patients; overall freedom from recurrences was 60.0%. CONCLUSION: A CCT-based preprocedural assessment before VT ablation is feasible, showing high diagnostic concordance with EAM in detecting myocardial fibrosis.

17.
Heart Rhythm ; 2024 Aug 22.
Artículo en Inglés | MEDLINE | ID: mdl-39181485

RESUMEN

BACKGROUND: No data have been reported on cooling characteristics and the impact of variant pulmonary vein (PV) anatomy on atrial fibrillation (AF) recurrences after POLARx cryoballoon (CB) ablation. OBJECTIVE: The purpose of this study was to analyze the impact of PV anatomy variants and cooling characteristics after CB ablation from a large multicenter prospective registry. METHODS: The primary end point was defined as 1-year absence of any atrial tachyarrhythmias (ATAs: AF/atrial flutter/atrial tachycardia). Correlation between ATA recurrences and anatomy variants/cooling characteristics were evaluated. The secondary outcome was the rate of major periprocedural complications. RESULTS: A total of 429 consecutive patients diagnosed with paroxysmal AF (83.4%) or persistent AF (peAF; 16.6%) were enrolled. Twenty-eight patients (6.6%) exhibited an anatomical variant (common ostium: 4.0%; adjunctive PV: 2.6%). Nadir temperature, thaw time, and total deflation time were different between standard PVs and PV variants. After the blanking period, over a mean of 431 ± 99 days of follow-up, 63 patients (14.7%) suffered an ATA recurrence. Patients with recurrences had both a shorter thaw time (18.5 ± 7 seconds vs 19.8 ± 7 seconds; P = .0012) and a shorter total deflation time, whereas time to isolation was longer (57.4 ± 42 seconds vs 49.1 ± 33 seconds; P = .04). Patients with anatomy variants showed a similar ATA recurrence rate (5 of 28 [17.9%]) to the standard PV anatomy group (58 of 401 [14.5%]) (P = .584), with a hazard ratio (HR) of 1.43 (95% confidence interval [CI] 0.49-4.13; log-rank, P = .4384). After adjusting for confounders, heart failure (HR 4.12; 95% CI 1.75-9.73; P = .0013) and peAF (HR 1.81; 95% CI 1.03-3.18; P = .0433) remained associated with ATA recurrence during follow-up. CONCLUSION: The POLARx CB system demonstrated long-term efficacy, along with a safe profile, in both patients with paroxysmal AF and those with peAF, regardless of the presence PV variants. Time to isolation was longer in patients with ATA recurrences during follow-up. CLINICAL TRIAL REGISTRATION: Catheter Ablation of Arrhythmias with a High-Density Mapping System in Real-World Practice (CHARISMA). CLINICALTRIALS: gov identifier: NCT03793998. Registration date: January 4, 2019.

18.
Heart Rhythm ; 2024 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-39029882

RESUMEN

BACKGROUND: Limited data are available on leadless pacemaker (LPM) outcomes according to different stages of chronic kidney disease (CKD). OBJECTIVE: The purpose of this study was to investigate differences in the safety and efficacy of LPMs among patients stratified per different stages of renal function. METHODS: Consecutive patients enrolled in the multicenter international i-LEAPER registry (International LEAdless PacemakEr Registry) were analyzed. Patients were divided into 3 groups according to CKD stage. The primary end point was the comparison of LPM-related major complication rate at implantation and during follow-up. Differences in electrical performance were deemed secondary outcomes. RESULTS: Of the 1748 patients enrolled, 33% were in CKD stage G3a/G3b and 9.4% were in CKD stage G4/G5. Patients with CKD presented cardiovascular comorbidities more frequently. During a median follow-up of 39 months (interquartile range [IQR] 18-59 months), major complication rate did not differ between groups (normal kidney function [NKF] group 1.8% vs CKD stage G3a/G3b group 2.9% vs CKD stage G4/G5 group 2.4%; P = .418). All-cause mortality resulted higher in the CKD stage G4/G5 group than in the NKF group (19.5% vs 9.8%; adjusted hazard ratio 1.9; 95% confidence interval 1.25-2.89; P = .003). LPM electrical performance was comparable between groups, except for patients with CKD who showed a slightly higher pacing threshold during 1-month follow-up (NKF group 0.50 V [IQR 0.35-0.70 V] vs G3a/G3b group 0.56 V [IQR 0.38-0.81 V] vs G4/G5 group 0.51 V [0.38-0.84 V] @ 0.24 ms; P < .001). CONCLUSION: In a real-world setting, patients with advanced CKD who underwent LPM implantation were underrepresented. Although all-cause mortality was higher in end-stage CKD, periprocedural complications and LPM performance were overall comparable between NKF and different stages of CKD, except for higher values of pacing threshold in patients with CKD up to first-month follow-up.

19.
Int J Cardiol ; 371: 197-203, 2023 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-36115442

RESUMEN

BACKGROUND: Age-related differences on leadless pacemaker (LP) are poorly described. Aim of this study was to compare clinical indications, periprocedural and mid-term device-associated outcomes in a large real-world cohort of LP patients, stratified by age at implantation. METHODS: Two cohorts of younger and older patients (≤50 and > 50 years old) were retrieved from the iLEAPER registry. The primary outcome was to compare the underlying indication why a LP was preferred over a transvenous PM across the two cohorts. Rates of peri-procedural and mid-term follow-up major complications as well as LP electrical performance were deemed secondary outcomes. RESULTS: 1154 patients were enrolled, with younger patients representing 6.2% of the entire cohort. Infective and vascular concerns were the most frequent characteristics that led to a LP implantation in the older cohort (45.8% vs 67.7%, p < 0.001; 4.2% vs 16.4%, p = 0.006), while patient preference was the leading cause to choose a LP in the younger (47.2% vs 5.6%, p < 0.001). Median overall procedural (52 [40-70] vs 50 [40-65] mins) and fluoroscopy time were similar in both groups. 4.3% of patients experienced periprocedural complications, without differences among groups. Threshold values were higher in the younger, both at discharge and at last follow-up (0.63 [0.5-0.9] vs 0.5 [0.38-0-7] V, p = 0.004). CONCLUSION: When considering LP indications, patient preference was more common in younger, while infective and vascular concerns were more frequent in the older cohort. Rates of device-related complications did not differ significantly. Younger patients tended to have a slightly higher pacing threshold at mid-term follow-up.


Asunto(s)
Marcapaso Artificial , Humanos , Persona de Mediana Edad , Resultado del Tratamiento , Diseño de Equipo , Marcapaso Artificial/efectos adversos , Factores de Tiempo , Estimulación Cardíaca Artificial/efectos adversos
20.
Europace ; 14(2): 209-16, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21933801

RESUMEN

AIMS: Chest computed tomography (CT) scanning is increasingly used as an imaging technique in patients undergoing atrial fibrillation (AF) catheter ablation. Chest CT scans visualize organs other than the heart and collateral findings may be identified incidentally. Our study aims to assess the prevalence and clinical relevance of such collateral findings in patients undergoing AF ablation. METHODS AND RESULTS: One hundred and seventy-three patients (127 males, age 59 ± 10 years) underwent chest CT scan for image integration in AF ablation. Collateral findings from visualized thoracic and upper abdominal organs were collected. Findings that required further investigations or treatment according to current guidelines were considered as clinically significant. A total of 164 collateral findings were identified in 97 (56%) patients, and most patients showed abnormalities of the lungs (67 patients, 39%). Forty-nine (28%) patients had clinically significant findings needing further investigation and 17 (10%) of them required specific treatments, including three cases (1.7 %) of lung malignancy. CONCLUSIONS: Chest CT images acquired for integration in AF ablation should be read thoroughly as they may serve as a screening tool for otherwise unrecognized clinically significant conditions of the heart, lungs, or other visualized organs.


Asunto(s)
Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Hepatopatías/epidemiología , Enfermedades Pulmonares/epidemiología , Radiografía Torácica/estadística & datos numéricos , Tomografía Computarizada por Rayos X/estadística & datos numéricos , Fibrilación Atrial/diagnóstico por imagen , Comorbilidad , Femenino , Humanos , Italia/epidemiología , Hepatopatías/diagnóstico por imagen , Enfermedades Pulmonares/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Prevalencia , Medición de Riesgo , Factores de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA