Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Eur Heart J ; 45(14): 1255-1265, 2024 Apr 07.
Artículo en Inglés | MEDLINE | ID: mdl-38445836

RESUMEN

BACKGROUND AND AIMS: Available data on continuous rhythm monitoring by implantable loop recorders (ILRs) in patients with Brugada syndrome (BrS) are scarce. The aim of this multi-centre study was to evaluate the diagnostic yield and clinical implication of a continuous rhythm monitoring strategy by ILRs in a large cohort of BrS patients and to assess the precise arrhythmic cause of syncopal episodes. METHODS: A total of 370 patients with BrS and ILRs (mean age 43.5 ± 15.9, 33.8% female, 74.1% symptomatic) from 18 international centers were included. Patients were followed with continuous rhythm monitoring for a median follow-up of 3 years. RESULTS: During follow-up, an arrhythmic event was recorded in 30.7% of symptomatic patients [18.6% atrial arrhythmias (AAs), 10.2% bradyarrhythmias (BAs), and 7.3% ventricular arrhythmias (VAs)]. In patients with recurrent syncope, the aetiology was arrhythmic in 22.4% (59.3% BAs, 25.0% VAs, and 15.6% AAs). The ILR led to drug therapy initiation in 11.4%, ablation procedure in 10.9%, implantation of a pacemaker in 2.5%, and a cardioverter-defibrillator in 8%. At multivariate analysis, the presence of symptoms [hazard ratio (HR) 2.5, P = .001] and age >50 years (HR 1.7, P = .016) were independent predictors of arrhythmic events, while inducibility of ventricular fibrillation at the electrophysiological study (HR 9.0, P < .001) was a predictor of VAs. CONCLUSIONS: ILR detects arrhythmic events in nearly 30% of symptomatic BrS patients, leading to appropriate therapy in 70% of them. The most commonly detected arrhythmias are AAs and BAs, while VAs are detected only in 7% of cases. Symptom status can be used to guide ILR implantation.


Asunto(s)
Síndrome de Brugada , Desfibriladores Implantables , Marcapaso Artificial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Arritmias Cardíacas/complicaciones , Arritmias Cardíacas/diagnóstico , Síndrome de Brugada/complicaciones , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/terapia , Electrocardiografía/métodos , Electrocardiografía Ambulatoria/métodos , Adulto
2.
Europace ; 25(3): 896-904, 2023 03 30.
Artículo en Inglés | MEDLINE | ID: mdl-36738245

RESUMEN

AIMS: The multielectrode radiofrequency balloon catheter (RFB) has been developed to achieve safe and effective pulmonary vein isolation (PVI) for atrial fibrillation (AF) ablation. This single-centre study aimed to evaluate the midterm clinical outcome and predictors of single-shot PVI with the novel RFB. METHODS AND RESULTS: All consecutive patients with symptomatic paroxysmal or persistent AF undergoing first-time PVI with the RFB were prospectively included. Clinical and procedural parameters were systematically collected. The primary safety endpoint was defined as any major periprocedural complications. The primary efficacy endpoint consisted of freedom from any atrial tachyarrhythmias (ATas) lasting >30 s during the follow-up after a 3-month blanking period. Persistent single-shot PVI was defined as PVI achieved with a single RFB application without acute reconnection. A total of 104 consecutive patients (mean age 64.3 ± 11.4 years, 56.7% males) were included. 15 patients (14.4%) presented with persistent AF. The procedure time was 59.0 min with a dwell time of 20.0 min. One major complication occurred in one patient. At a mean follow-up of 10.1 ± 5.3 months, freedom from ATas was 82.9%. ATas occurred in 14 patients, 11/69 patients (15.9%) with paroxysmal AF and 3/13 (23.1%) with persistent AF. The best cut-offs to predict persistent single-shot PVI were impedance drop >19.2 Ω [area under the receiver operator characteristic curve (AUC) 0.74] and temperature rise >11.1° C (AUC 0.77). CONCLUSION: In a large cohort of patients undergoing PVI with the RFB, the complication rate was 1%. At a mid-term follow-up of 10.1 ± 5.3 months, freedom from ATas was 82.9%. Specific cut-offs of impedance drop and temperature rise may be useful to predict persistent single-shot isolation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Masculino , Humanos , Persona de Mediana Edad , Anciano , Femenino , Resultado del Tratamiento , Estudios de Seguimiento , Estudios Prospectivos , Venas Pulmonares/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Taquicardia/cirugía , Catéteres , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia
3.
Europace ; 25(5)2023 05 19.
Artículo en Inglés | MEDLINE | ID: mdl-37246904

RESUMEN

AIMS: Hybrid atrial fibrillation (AF) ablation is a promising approach in non-paroxysmal AF. The aim of this study is to assess the long-term outcomes of hybrid ablation in a large cohort of patients after both an initial and as a redo procedure. METHODS AND RESULTS: All consecutive patients undergoing hybrid AF ablation at UZ Brussel from 2010 to 2020 were retrospectively evaluated. Hybrid AF ablation was performed in a one-step procedure: (i) thoracoscopic ablation followed by (ii) endocardial mapping and eventual ablation. All patients received PVI and posterior wall isolation. Additional lesions were performed based on clinical indication and physician judgement. Primary endpoint was freedom from atrial tachyarrhythmias (ATas). A total of 120 consecutive patients were included, 85 patients (70.8%) underwent hybrid AF ablation as first procedure (non-paroxysmal AF 100%), 20 patients (16.7%) as second procedure (non-paroxysmal AF 30%), and 15 patients (12.5%) as third procedure (non-paroxysmal AF 33.3%). After a mean follow-up of 62.3 months ± 20.3, a total of 63 patients (52.5%) experienced ATas recurrence. Complications occurred in 12.5% of patients. There was no difference in ATas between patients undergoing hybrid as first vs. redo procedure (P = 0.53). Left atrial volume index and recurrence during blanking period were independent predictors of ATas recurrence. CONCLUSION: In a large cohort of patients undergoing hybrid AF ablation, the survival from ATas recurrence was 47.5% at ≈5 years follow-up. There was no difference in clinical outcomes between patients undergoing hybrid AF ablation as first procedure or as a redo.


Asunto(s)
Técnicas de Ablación , Fibrilación Atrial , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Estudios de Seguimiento , Atrios Cardíacos , Estudios Retrospectivos , Taquicardia , Resultado del Tratamiento
4.
Europace ; 26(1)2023 12 28.
Artículo en Inglés | MEDLINE | ID: mdl-38155611

RESUMEN

AIMS: A novel sinus node (SN) sparing hybrid ablation for inappropriate sinus node tachycardia (IST)/postural orthostatic tachycardia syndrome (POTS) has been demonstrated to be an effective and safe therapeutic option in patients with symptomatic drug-resistant IST/POTS. The aim of this study was to evaluate the long-term rate of redo procedures after hybrid IST ablation and procedural strategy, outcomes and safety of redo procedures. METHODS AND RESULTS: All consecutive patients from 2015 to 2023 were prospectively enrolled in the UZ Brussel monocentric IST/POTS registry. They were analysed if the following inclusion criteria were fulfilled: 1) diagnosis of IST or POTS, 2) symptomatic IST/POTS refractory or intolerant to drugs, and 3) hybrid SN sparing ablation performed. The primary endpoint was redo procedure. The primary safety endpoint was pacemaker (PM) implantation. A total of 220 patients undergone to hybrid IST ablation were included, 185 patients (84.1%) were treated for IST and 61 patients (27.7%) for POTS.After a follow-up of 73.3 ± 16.2 months, 34 patients (15.4%) underwent a redo. A total of 23 patients (67.6%) had a redo for IST recurrence and 11 patients (32.4%) for other arrhythmias. Pacemaker implantation was performed in 21 patients (9.5%). Nine patients (4.1%) had no redo procedure and experienced sick sinus syndrome requiring a PM. Twelve patients (5.4%) received a PM as a shared therapeutic choice combined with SN ablation procedure. CONCLUSION: In a large cohort of patients the long-term free survival from redo procedure after hybrid IST ablation was 84.6% with a low PM implantation rate.


Asunto(s)
Ablación por Catéter , Taquicardia Sinusal , Humanos , Taquicardia Sinusal/diagnóstico , Taquicardia Sinusal/cirugía , Taquicardia Sinusal/tratamiento farmacológico , Nodo Sinoatrial , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Frecuencia Cardíaca
5.
Europace ; 25(5)2023 05 19.
Artículo en Inglés | MEDLINE | ID: mdl-37061847

RESUMEN

AIMS: A pathogenic/likely pathogenic (P/LP) variant in SCN5A is found in 20-25% of patients with Brugada syndrome (BrS). However, the diagnostic yield and prognosis of gene panel testing in paediatric BrS is unclear. The aim of this study is to define the diagnostic yield and outcomes of SCN5A gene testing with ACMG variant classification in paediatric BrS patients compared with adults. METHODS AND RESULTS: All consecutive patients diagnosed with BrS, between 1992 and 2022, were prospectively enrolled in the UZ Brussel BrS registry. Inclusion criteria were: (i) BrS diagnosis; (ii) genetic analysis performed with a large gene panel; and (iii) classification of gene variants following ACMG guidelines. Paediatric patients were defined as ≤16 years of age. The primary endpoint was ventricular arrhythmias (VAs). A total of 500 BrS patients were included, with 63 paediatric patients and 437 adult patients. Among children with BrS, 29 patients (46%) had a P/LP variant (P+) in SCN5A and no variants were found in 34 (54%) patients (P-). After a mean follow-up of 125.9 months, 8 children (12.7%) experienced a VA, treated with implanted cardioverter defibrillator shock. At survival analysis, P- paediatric patients had higher VA-free survival during the follow-up, compared with P+ paediatric patients. P+ status was an independent predictor of VA. There was no difference in VA-free survival between paediatric and adult BrS patients for both P- and P+. CONCLUSION: In a large BrS cohort, the diagnostic yield for P/LP variants in the paediatric population is 46%. P+ children with BrS have a worse arrhythmic prognosis.


Asunto(s)
Síndrome de Brugada , Adulto , Humanos , Niño , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/genética , Síndrome de Brugada/terapia , Pruebas Genéticas , Arritmias Cardíacas/genética , Cardioversión Eléctrica , Pronóstico , Electrocardiografía/métodos , Canal de Sodio Activado por Voltaje NAV1.5/genética
6.
Clin Auton Res ; 33(1): 51-62, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36645559

RESUMEN

PURPOSE: Drug-induced type I Brugada syndrome (BrS) is associated with a ventricular arrhythmia (VA) rate of 1 case per 100 person-years. This study aims to evaluate changes in electrocardiographic (ECG) parameters such as microvolt T wave alternans (mTWA) and heart rate variability (HRV) at baseline and during ajmaline testing for BrS diagnosis. METHODS: Consecutive patients diagnosed with BrS during ajmaline testing with 5-year follow-up were included in this study. For comparison, a negative ajmaline control group and an isoproterenol control group were also included. ECG recordings during ajmaline or isoproterenol test were divided in two timeframes from which ECG parameters were calculated: a 5-min baseline timeframe and a 5-min drug timeframe. RESULTS: A total of 308 patients with BrS were included, 22 (0.7%) of which suffered VAs during follow-up. One hundred patients were included in both isoproterenol and negative ajmaline control groups. At baseline, there was no difference in ECG parameters between control groups and patients with BrS, nor between BrS with and without VAs. During ajmaline testing, BrS with VAs presented longer QRS duration [159 ± 34 ms versus 138 (122-155) ms, p = 0.006], higher maximum mTWA [33.8 (14.0-114) µV versus 8.00 (3.67-28.2) µV, p = 0.001], and lower power in low frequency band [25.6 (5.8-53.8) ms2 versus 129.5 (52.7-286) ms2, p < 0.0001] when compared to BrS without VAs. CONCLUSIONS: Ajmaline induced important HRV changes similar to those observed during isoproterenol. Increased mTWA was observed only in patients with BrS. BrS with VAs during follow-up presented worse changes during ajmaline test, including lower LF power and higher maximum mTWA which were independent predictors of events.


Asunto(s)
Ajmalina , Síndrome de Brugada , Humanos , Ajmalina/farmacología , Síndrome de Brugada/diagnóstico , Frecuencia Cardíaca , Isoproterenol , Arritmias Cardíacas , Electrocardiografía , Pronóstico
7.
Curr Cardiol Rep ; 25(6): 535-542, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37115434

RESUMEN

PURPOSE OF REVIEW: Imaging plays a crucial role in the therapy of ventricular tachycardia (VT). We offer an overview of the different methods and provide information on their use in a clinical setting. RECENT FINDINGS: The use of imaging in VT has progressed recently. Intracardiac echography facilitates catheter navigation and the targeting of moving intracardiac structures. Integration of pre-procedural CT or MRI allows for targeting the VT substrate, with major expected impact on VT ablation efficacy and efficiency. Advances in computational modeling may further enhance the performance of imaging, giving access to pre-operative simulation of VT. These advances in non-invasive diagnosis are increasingly being coupled with non-invasive approaches for therapy delivery. This review highlights the latest research on the use of imaging in VT procedures. Image-based strategies are progressively shifting from using images as an adjunct tool to electrophysiological techniques, to an integration of imaging as a central element of the treatment strategy.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/cirugía , Arritmias Cardíacas , Corazón , Frecuencia Cardíaca , Ablación por Catéter/métodos , Resultado del Tratamiento
8.
Pacing Clin Electrophysiol ; 45(5): 605-611, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35352363

RESUMEN

BACKGROUND: Left atrial posterior wall isolation (LAPWI) is often performed in addition to pulmonary vein isolation (PVI) in the setting of persistent atrial fibrillation (AF) ablation. The aim of this study was to evaluate the feasibility and safety of a new cryoballoon ablation system in achieving PVI + LAPWI isolation. METHODS: The study was a prospective, non-randomized, single center study. Forty consecutive patients, undergoing PVI + LAPWI with the novel POLARx™, were compared to 40 consecutive patients who underwent the same procedure with the established Arctic Front Advance PRO™. RESULTS: Acute isolation was achieved in all PVs in both groups and left posterior wall isolation (LAPWI) was achieved in 38 patients (95%) in the POLARx group and in 36 patients (90%) in Arctic Front group. Procedural outcomes were similar between both groups, except for lower temperatures during cryoenergy in the POLARx group, for both pulmonary vein isolation (PVI) and LAPWI. CONCLUSION: LAPWI + PVI with the novel POLARx™ Cryoballoon is feasible and safe; the results are comparable with the Arctic Front Advance PRO™ system.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Fibrilación Atrial/cirugía , Criocirugía/métodos , Estudios de Factibilidad , Humanos , Estudios Prospectivos , Venas Pulmonares/cirugía , Recurrencia , Tecnología , Resultado del Tratamiento
9.
Pacing Clin Electrophysiol ; 44(12): 2075-2083, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34773413

RESUMEN

BACKGROUND: Pulmonary vein (PV) isolation is an established treatment for paroxysmal drug-refractory atrial fibrillation (AF). High parasympathetic tone and reconnection of PVs have demonstrated to be possible culprits of AF recurrence after ablation. Our aim was to investigate the association between parasympathetic tone and reconnected PVs in patients with paroxysmal AF. METHODS: Consecutive patients who underwent a redo catheter ablation procedure for atrial tachyarrhythmia recurrence by means of 3D electroanatomic mapping with documentation of presence or absence of PVs reconnection following an initial procedure of cryoballoon (CB) ablation for symptomatic drug-refractory paroxysmal AF were screened for the study. RESULTS: A total of 92 patients were included, of whom 50 (54.35%) were males. Reconnected PVs were found in 64 (69%) patients. PVs reconnection could be predicted by DC (C-statistic = .770), by SDNNI (C-statistic = .714) and by absolute VLF power (C-statistic = .722), while right-sided PVs reconnection could be better predicted by DC (C-statistic = .848) and by SDNNI (C-statistic = .761). In multivariate binary logistic regression analysis, a DC value ≥6.45 ms and an absolute VLF power value ≥160 ms2 were associated with three times and five times higher odds of PVs reconnection, respectively. On a vein-per-vein analysis, absolute VLF power ≥160 ms2 was associated with three times higher odds, while reaching of -40°C within 60 s was associated with three times lower odds of PVs reconnection. CONCLUSION: High parasympathetic tonus accurately predicts PVs reconnection. On a vein-per-vein analysis, parasympathetic markers along with biophysical parameters predicted PVs reconnection. On a case-by-case analysis, parasympathetic markers were the only predictors of PVs reconnection, thus being a robust PVs reconnection prediction tool.


Asunto(s)
Fibrilación Atrial/cirugía , Sistema Nervioso Autónomo/fisiopatología , Criocirugía/métodos , Venas Pulmonares/cirugía , Nervio Vago/fisiopatología , Adulto , Mapeo Epicárdico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Reoperación
10.
J Viral Hepat ; 27(11): 1214-1221, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32593212

RESUMEN

Hepatitis C virus (HCV)-related chronic infection has been associated with a higher incidence of cardiovascular diseases. An altered morphology and function of both left and right heart have been described in HCV patients; however, the causality of the association is still debated. Ninety-eight nonobese and nondiabetic HCV patients (59.5 ± 12.0 years; males 52%) with Fibroscan-Transient Elastography assessed low-moderate liver fibrosis that achieved sustained viral response at 12 and 24 weeks after DAAs (direct-acting antivirals) participated. 56 were matched with 52 control subjects for age, sex and cardiovascular risk factors at baseline. A trans-thoracic echocardiography was performed in each subject at baseline (T0) and repeated in all HCV patients after eradication (6 months later eligibility, T1). TNF-α and IL-10 were measured at baseline and at T1. A concentric remodelling of the left heart in HCV participants was identified, whereas tricuspidal annular plane systolic excursion, right indexed atrial volume, right basal ventricular diameter, inferior vena cava diameter and pulmonary arterial pressure were higher in HCV participants compared to matched controls. After virus eradication, left indexed atrial volume and all right cardiac chambers measures were lower than baseline. A significant reduction of TNF-α was shown at T1, while IL-10 did not change. This study shows a concentric remodelling of the left ventricle and structural modifications in the right sections in HCV patients compared to controls. Virus eradication with DAAs was associated with a reduction of the main right atrioventricular parameters indicating a direct involvement of the HCV in cardiac changes.


Asunto(s)
Antivirales , Hepacivirus , Hepatitis C Crónica , Antivirales/uso terapéutico , Hepatitis C Crónica/tratamiento farmacológico , Humanos , Cirrosis Hepática/tratamiento farmacológico , Masculino
12.
Prof Inferm ; 70(2): 66-75, 2017.
Artículo en Italiano | MEDLINE | ID: mdl-28763180

RESUMEN

AIM: The management of operating rooms (ORs) is a complex process which requires an effective organizational scheme. In order to amore convinient allocation of resources a rigorous monitoring plan is needed to ensure operating rooms performances. All the necessary actions should be taken to improve the quality of the planning and scheduling procedure. METHODS: Between April-December, 2016 an organizational analysis has been carried out on the performances of the A.O. S. Camillo-Forlanini Hospital Operating Block applying the "process management" approach to the ORs efficiency. The project involved two different surgical areas of the same operating block the multi-specialist and elective surgery and cardio-vascular surgery . The analyses of the processes was made through the product, patient and safety approach and from different points of view: the "asis", process and stakeholder perspectives. Descriptive statistics was used to process raw data and Student's t-distribution was used to assess the difference between the two means (significant p value ˂0,05). The Coefficient of Variation (CV) was used to describe the variabilityamong data. RESULTS: The asis approach allowed us to describe the ORs inbound activities. For both operating block the most demanding weekly commitments in terms of time turned out to be the inventory management procedures of controlling and stocking medicines, general medical supplies and instruments (130[DS=±14] for BOE and 30[DS=±18] for CCH. The average time spent on preparing the operating room, separately calculated starting from the first surgical case, was of 27 minutes (SD=± 17) while for the following surgical procedures preparation time decreased to 15 minutes (SD= ± 10), which highlighted a meaningful difference of 12 minutes. A great variability was registered in CCH due to the unpredictability of these operations (CV 82%). The stakeholders' perspective revealed a reasonable level of satisfaction among nurses and surgeons (2.9 vs 2.3, respectively) and in anesthesiologist (2.8-BOE vs 2.4 CCH).Being brought to the surgical suite from an "external Unit" seems to have negatively influenced the patient's perception: preparation time turned out to be significantly lower for CCH patients rather than BOE ones (p˂0,001).The results of the safety procedure approach highlighted a moderate criticality in terms of cleaning up time and delay in the starting time of the first surgical case. CONCLUSION: More effort should be made to avoid any slowdown during the whole process. It is advisable to implement a lean system that may improve efficiency and quality of the service to reduce wastes and unproductive times. This would inevitably generate a more positive outcomes.


Asunto(s)
Eficiencia Organizacional , Hospitales , Quirófanos/organización & administración , Humanos , Quirófanos/normas , Mejoramiento de la Calidad , Ciudad de Roma
14.
J Interv Card Electrophysiol ; 67(2): 273-283, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37103590

RESUMEN

BACKGROUND: Posterior wall (PW) isolation is an important adjunctive ablation target in patients with non-paroxysmal atrial fibrillation (AF). Traditionally performed with point-by-point radiofrequency (RF) ablation, PW isolation has also been performed with different cryoballoon technologies. We aimed at assessing the feasibility of PW isolation with the novel RF balloon catheter Heliostar™ (Biosense Webster, CA, USA). METHODS: We prospectively enrolled 32 consecutive patients with persistent AF scheduled for first-time ablation with the Heliostar™ device. Procedural data were compared with those from 96 consecutive persistent AF patients undergoing pulmonary vein (PV) plus PW isolation with a cryoballoon device. The ratio RF balloon/cryoballoon was 1:3 for each operator involved in the study, aiming at avoiding any imbalance related to different experience. RESULTS: Single-shot PV isolation was documented in a significantly higher number of cases with the RF balloon technology compared to cryoballoon ablation (89.8% vs. 81.0%; p = 0.02, respectively). PW isolation was achieved with a similar number of balloon applications between the two groups (11 ± 4 with the RF balloon versus 11 ± 2 with the cryoballoon; p = 0.16), but in a significantly shorter time among RF balloon patients (228 ± 72 s versus 1274 ± 277 s with cryoballoon; p < 0.001). Primary safety endpoint occurred in none of the RF balloon patients versus 5 (5.2%) patients in the cryoballoon group (p = 0.33). Primary efficacy endpoint was achieved in all (100%) RF balloon patients versus 93 (96.9%) cryoballoon ones (p = 0.57). Oesophageal endoscopy did not show any signs of thermal lesions in RF balloon patients with luminal temperature rise. CONCLUSIONS: RF balloon-based PW isolation was safe and promoted shorter procedure times compared to similar cryoballoon-based ablation procedures.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Criocirugía/métodos , Estudios de Factibilidad , Resultado del Tratamiento , Ablación por Catéter/métodos , Recurrencia , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Venas Pulmonares/cirugía , Catéteres
15.
J Am Heart Assoc ; 13(10): e033148, 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38726893

RESUMEN

BACKGROUND: Brugada syndrome (BrS) has been associated with sudden cardiac death in otherwise healthy subjects, and drug-induced BrS accounts for 55% to 70% of all patients with BrS. This study aims to develop a deep convolutional neural network and evaluate its performance in recognizing and predicting BrS diagnosis. METHODS AND RESULTS: Consecutive patients who underwent ajmaline testing for BrS following a standardized protocol were included. ECG tracings from baseline and during ajmaline were transformed using wavelet analysis and a deep convolutional neural network was separately trained to (1) recognize and (2) predict BrS type I pattern. The resultant networks are referred to as BrS-Net. A total of 1188 patients were included, of which 361 (30.3%) patients developed BrS type I pattern during ajmaline infusion. When trained and evaluated on ECG tracings during ajmaline, BrS-Net recognized a BrS type I pattern with an AUC-ROC of 0.945 (0.921-0.969) and an AUC-PR of 0.892 (0.815-0.939). When trained and evaluated on ECG tracings at baseline, BrS-Net predicted a BrS type I pattern during ajmaline with an AUC-ROC of 0.805 (0.845-0.736) and an AUC-PR of 0.605 (0.460-0.664). CONCLUSIONS: BrS-Net, a deep convolutional neural network, can identify BrS type I pattern with high performance. BrS-Net can predict from baseline ECG the development of a BrS type I pattern after ajmaline with good performance in an unselected population.


Asunto(s)
Ajmalina , Síndrome de Brugada , Aprendizaje Profundo , Electrocardiografía , Humanos , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/fisiopatología , Síndrome de Brugada/inducido químicamente , Electrocardiografía/efectos de los fármacos , Masculino , Femenino , Ajmalina/efectos adversos , Persona de Mediana Edad , Adulto , Valor Predictivo de las Pruebas , Estudios Retrospectivos
16.
Heart Rhythm O2 ; 5(2): 137-144, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38545325

RESUMEN

Background: Pericarditis is the most common complication following hybrid sinus node-sparing ablation for inappropriate sinus tachycardia (IST)/postural orthostatic tachycardia syndrome (POTS). Objective: The study sought to evaluate the association of prophylaxis therapy on the risk of symptomatic pericarditis following hybrid IST/POTS ablation. Methods: All consecutive patients undergoing to hybrid ablation of symptomatic IST/POTS refractory or intolerant to drugs were retrospectively analyzed. Pharmacological prophylaxis therapy was based on acetylsalicylic acid and colchicine started on the day of the ablation and continued for at least 3 months. The primary endpoint was occurrence of symptomatic pericarditis. The secondary endpoint was occurrence of pericarditis-related complications, including the following: duration of pericarditis >3 months, hospitalization for pericarditis, postpericardiectomy pleuro-pericarditis, and pericardiectomy. Results: A total of 220 patients undergone to hybrid IST/POTS ablation were included and 44 (20%) underwent prophylaxis therapy. Pericarditis occurred in 101 (45.9%) patients, with 97 (96%) in the first 5 days. At survival analysis, prophylaxis was associated with higher rate of freedom from pericarditis (81.9% vs 47.2%, log-rank P < .001). Pericarditis-related complications were low, occurring in 7 (3.2%) patients. There was no difference in pericarditis-related complications between the patients who underwent prophylaxis therapy and patients who did not. At Cox multivariate analysis, predictors of pericarditis were IST (vs POTS) (hazard ratio 0.61, 95% confidence interval0.39-0.99, P = .04) and prophylaxis therapy (hazard ratio 0.27, 95% confidence interval 0.13-0.55, P < .001). Conclusion: In a large cohort of patients undergoing hybrid ablation for IST/POTS, a prophylaxis therapy with acetylsalicylic acid and colchicine was associated with a lower rate of symptomatic pericarditis.

17.
Biomedicines ; 12(4)2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38672223

RESUMEN

To date, studies assessing the safety profile of 3D printing materials for application in cardiac ablation are sparse. Our aim is to evaluate the safety and feasibility of two biocompatible 3D printing materials, investigating their potential use for intra-procedural guides to navigate surgical cardiac arrhythmia ablation. Herein, we 3D printed various prototypes in varying thicknesses (0.8 mm-3 mm) using a resin (MED625FLX) and a thermoplastic polyurethane elastomer (TPU95A). Geometrical testing was performed to assess the material properties pre- and post-sterilization. Furthermore, we investigated the thermal propagation behavior beneath the 3D printing materials during cryo-energy and radiofrequency ablation using an in vitro wet-lab setup. Moreover, electron microscopy and Raman spectroscopy were performed on biological tissue that had been exposed to the 3D printing materials to assess microparticle release. Post-sterilization assessments revealed that MED625FLX at thicknesses of 1 mm, 2.5 mm, and 3 mm, along with TPU95A at 1 mm and 2.5 mm, maintained geometrical integrity. Thermal analysis revealed that material type, energy source, and their factorial combination with distance from the energy source significantly influenced the temperatures beneath the 3D-printed material. Electron microscopy revealed traces of nitrogen and sulfur underneath the MED625FLX prints (1 mm, 2.5 mm) after cryo-ablation exposure. The other samples were uncontaminated. While Raman spectroscopy did not detect material release, further research is warranted to better understand these findings for application in clinical settings.

18.
Heart Rhythm ; 21(6): 780-787, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38290688

RESUMEN

BACKGROUND: Pulsed field ablation (PFA) is selective for the myocardium. However, vagal responses and reversible effects on ganglionated plexi (GP) are observed during pulmonary vein isolation (PVI). Anterior-right GP ablation has been proven to effectively prevent vagal responses during radiofrequency-based PVI. OBJECTIVE: The purpose of this study was to test the hypothesis that PFA-induced transient anterior-right GP modulation when targeting the right superior pulmonary vein (RSPV) before any other pulmonary veins (PVs) may effectively prevent intraprocedural vagal responses. METHODS: Eighty consecutive paroxysmal atrial fibrillation patients undergoing PVI with PFA were prospectively included. In the first 40 patients, PVI was performed first targeting the left superior pulmonary vein (LSPV-first group). In the last 40 patients, RSPV was targeted first, followed by left PVs and right inferior PV (RSPV-first group). Heart rate (HR) and extracardiac vagal stimulation (ECVS) were evaluated at baseline, during PVI, and postablation to assess GP modulation. RESULTS: Vagal responses occurred in 31 patients (78%) in the LSPV-first group and 5 (13%) in the RSPV-first group (P <.001). Temporary pacing was needed in 14 patients (35%) in the LSPV-first group and 3 (8%) in the RSPV-first group (P = .003). RSPV isolation was associated with similar acute HR increase in the 2 groups (13 ± 11 bpm vs 15 ± 12 bpm; P = .3). No significant residual changes in HR or ECVS response were documented in both groups at the end of the procedure compared to baseline (all P >.05). CONCLUSION: PVI with PFA frequently induced vagal responses when initiated from the LSPV. Nevertheless, an RSPV-first approach promoted transient HR increase and reduced vagal response occurrence.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Frecuencia Cardíaca , Venas Pulmonares , Nervio Vago , Humanos , Venas Pulmonares/cirugía , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Masculino , Femenino , Ablación por Catéter/métodos , Persona de Mediana Edad , Frecuencia Cardíaca/fisiología , Nervio Vago/fisiopatología , Nervio Vago/fisiología , Estudios Prospectivos , Sistema de Conducción Cardíaco/fisiopatología , Anciano , Resultado del Tratamiento , Ganglios Autónomos/fisiopatología , Ganglios Autónomos/cirugía , Estudios de Seguimiento
19.
Circ Arrhythm Electrophysiol ; 17(4): e012374, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38426305

RESUMEN

BACKGROUND: A pathogenic/likely pathogenic variant can be found in 20% to 25% of patients with Brugada syndrome (BrS) and a pathogenic/likely pathogenic variant in SCN5A is associated with a worse prognosis. The aim of this study is to define the diagnostic yield of a large gene panel with American College of Medical Genetics and Genomics variant classification and to assess prognosis of SCN5A and non-SCN5A variants. METHODS: All patients with BrS, were prospectively enrolled in the Universitair Ziekenhuis Brussel registry between 1992 and 2022. Inclusion criteria for the study were (1) BrS diagnosis; (2) genetic analysis performed with a large gene panel; (3) classification of variants following American College of Medical Genetics and Genomics guidelines. Patients with a pathogenic/likely pathogenic variant in SCN5A were defined as SCN5A+. Patients with a reported variant in a non-SCN5A gene or with no reported variants were defined as patients with SCN5A-. All variants were classified as missense or predicted loss of function. RESULTS: A total of 500 BrS patients were analyzed. A total of 104 patients (20.8%) were SCN5A+ and 396 patients (79.2%) were SCN5A-. A non-SCN5A gene variant was found in 75 patients (15.0%), of whom, 58 patients (77.3%) had a missense variant and 17 patients (22.7%) had a predicted loss of function variant. At a follow-up of 84.0 months, 48 patients (9.6%) experienced a ventricular arrhythmia (VA). Patients without any variant had higher VA-free survival, compared with carriers of a predicted loss of function variant in SCN5A+ or non-SCN5A genes. There was no difference in VA-free survival between patients without any variant and missense variant carriers in SCN5A+ or non-SCN5A genes. At Cox analysis, SCN5A+ or non-SCN5A predicted loss of function variant was an independent predictor of VA. CONCLUSIONS: In a large BrS cohort, the yield for SCN5A+ is 20.8%. A predicted loss of function variant carrier is an independent predictor of VA.


Asunto(s)
Síndrome de Brugada , Humanos , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/genética , Pruebas Genéticas , Arritmias Cardíacas/genética , Mutación Missense , Canal de Sodio Activado por Voltaje NAV1.5/genética , Mutación
20.
Front Bioeng Biotechnol ; 11: 1044647, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36714012

RESUMEN

Background: In the field of medicine, photogrammetry has played for long time a marginal role due to the significant amount of work required that made it impractical for an extended medical use. Developments in digital photogrammetry occurred in the recent years, that have steadily increased the interest and application of this technique. The present study aims to compare photogrammetry reconstruction of heart with computed tomography (CT) as a reference. Methods: The photogrammetric reconstructions of digital images from ECG imaging derived images were performed. In particular, the ventricles of 15 patients with Brugada syndrome were reconstructed by using the free Zephyr Lite software. In order to evaluate the accuracy of the technique, measurements on the reconstructions were compared to patient-specific CT scan imported in ECG imaging software UZBCIT. Result: The results showed that digital photogrammetry in the context of ventricle reconstruction is feasible. The photogrammetric derived measurements of ventricles were not statistically different from CT scan measurements. Furthermore, the analysis showed high correlation of photogrammetry reconstructions with CT scan and a correlation coefficient close to 1. Conclusion: It is possible to reproduce digital objects by photogrammetry if the process described in this study is performed. The reconstruction of the ventricles from CT scan was very close to the values of the respective photogrammetric reconstruction.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA