Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
J Synchrotron Radiat ; 26(Pt 2): 406-412, 2019 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-30855249

RESUMEN

Serial synchrotron crystallography allows low X-ray dose, room-temperature crystal structures of proteins to be determined from a population of microcrystals. Protein production and crystallization is a non-trivial procedure and it is essential to have X-ray-compatible sample environments that keep sample consumption low and the crystals in their native environment. This article presents a fast and optimized manufacturing route to metal-polyimide microfluidic flow-focusing devices which allow for the collection of X-ray diffraction data in flow. The flow-focusing conditions allow for sample consumption to be significantly decreased, while also opening up the possibility of more complex experiments such as rapid mixing for time-resolved serial crystallography. This high-repetition-rate experiment allows for full datasets to be obtained quickly (∼1 h) from crystal slurries in liquid flow. The X-ray compatible microfluidic chips are easily manufacturable, reliable and durable and require sample-flow rates on the order of only 30 µl h-1.

2.
Biochemistry ; 56(37): 4931-4939, 2017 09 19.
Artículo en Inglés | MEDLINE | ID: mdl-28832133

RESUMEN

The antimetabolite pentyl pantothenamide has broad spectrum antibiotic activity but exhibits enhanced activity against Escherichia coli. The PanDZ complex has been proposed to regulate the pantothenate biosynthetic pathway in E. coli by limiting the supply of ß-alanine in response to coenzyme A concentration. We show that formation of such a complex between activated aspartate decarboxylase (PanD) and PanZ leads to sequestration of the pyruvoyl cofactor as a ketone hydrate and demonstrate that both PanZ overexpression-linked ß-alanine auxotrophy and pentyl pantothenamide toxicity are due to formation of this complex. This both demonstrates that the PanDZ complex regulates pantothenate biosynthesis in a cellular context and validates the complex as a target for antibiotic development.


Asunto(s)
Acetilcoenzima A/metabolismo , Carboxiliasas/metabolismo , Escherichia coli K12/metabolismo , Proteínas de Escherichia coli/metabolismo , Glutamato Descarboxilasa/metabolismo , Modelos Moleculares , Acetilcoenzima A/análogos & derivados , Acetilcoenzima A/química , Sustitución de Aminoácidos , Antibacterianos/farmacología , Antimetabolitos/farmacología , Sitios de Unión , Calorimetría , Carboxiliasas/química , Carboxiliasas/genética , Coenzima A/síntesis química , Coenzima A/química , Coenzima A/metabolismo , Cristalografía por Rayos X , Activación Enzimática/efectos de los fármacos , Escherichia coli K12/efectos de los fármacos , Escherichia coli K12/crecimiento & desarrollo , Proteínas de Escherichia coli/química , Proteínas de Escherichia coli/genética , Eliminación de Gen , Glutamato Descarboxilasa/antagonistas & inhibidores , Glutamato Descarboxilasa/química , Glutamato Descarboxilasa/genética , Cinética , Mutación , Ácido Pantoténico/análogos & derivados , Ácido Pantoténico/farmacología , Conformación Proteica , Multimerización de Proteína , Proteínas Recombinantes/química , Proteínas Recombinantes/metabolismo , Volumetría
3.
Biochem Biophys Res Commun ; 426(3): 350-5, 2012 Sep 28.
Artículo en Inglés | MEDLINE | ID: mdl-22940551

RESUMEN

The existence of a fifth essential protein for pantothenate biosynthesis in some enteric bacteria has recently been reported by Stuecker et al. [10] and Nozaki et al. (in press) [9]. This protein, PanZ, catalyses the activation of the PanD zymogen to form ADC and is essential for prototrophic growth. In this paper, we characterise the interaction of PanZ with coenzyme A and a constitutively inactive mutant of PanD using a combination of isothermal titration calorimetry and mass spectrometry. These approaches reveal that the two proteins interact with nanomolar affinity in a CoA-dependent fashion to form a heterooctameric complex.


Asunto(s)
Coenzima A/química , Precursores Enzimáticos/química , Glutamato Descarboxilasa/química , Calorimetría , Multimerización de Proteína
4.
IUCrJ ; 9(Pt 5): 610-624, 2022 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-36071813

RESUMEN

Room-temperature macromolecular crystallography allows protein structures to be determined under close-to-physiological conditions, permits dynamic freedom in protein motions and enables time-resolved studies. In the case of metalloenzymes that are highly sensitive to radiation damage, such room-temperature experiments can present challenges, including increased rates of X-ray reduction of metal centres and site-specific radiation-damage artefacts, as well as in devising appropriate sample-delivery and data-collection methods. It can also be problematic to compare structures measured using different crystal sizes and light sources. In this study, structures of a multifunctional globin, dehaloperoxidase B (DHP-B), obtained using several methods of room-temperature crystallographic structure determination are described and compared. Here, data were measured from large single crystals and multiple microcrystals using neutrons, X-ray free-electron laser pulses, monochromatic synchrotron radiation and polychromatic (Laue) radiation light sources. These approaches span a range of 18 orders of magnitude in measurement time per diffraction pattern and four orders of magnitude in crystal volume. The first room-temperature neutron structures of DHP-B are also presented, allowing the explicit identification of the hydrogen positions. The neutron data proved to be complementary to the serial femtosecond crystallography data, with both methods providing structures free of the effects of X-ray radiation damage when compared with standard cryo-crystallography. Comparison of these room-temperature methods demonstrated the large differences in sample requirements, data-collection time and the potential for radiation damage between them. With regard to the structure and function of DHP-B, despite the results being partly limited by differences in the underlying structures, new information was gained on the protonation states of active-site residues which may guide future studies of DHP-B.

5.
Nat Commun ; 13(1): 4708, 2022 08 11.
Artículo en Inglés | MEDLINE | ID: mdl-35953469

RESUMEN

The European X-ray Free Electron Laser (XFEL) and Linac Coherent Light Source (LCLS) II are extremely intense sources of X-rays capable of generating Serial Femtosecond Crystallography (SFX) data at megahertz (MHz) repetition rates. Previous work has shown that it is possible to use consecutive X-ray pulses to collect diffraction patterns from individual crystals. Here, we exploit the MHz pulse structure of the European XFEL to obtain two complete datasets from the same lysozyme crystal, first hit and the second hit, before it exits the beam. The two datasets, separated by <1 µs, yield up to 2.1 Å resolution structures. Comparisons between the two structures reveal no indications of radiation damage or significant changes within the active site, consistent with the calculated dose estimates. This demonstrates MHz SFX can be used as a tool for tracking sub-microsecond structural changes in individual single crystals, a technique we refer to as multi-hit SFX.


Asunto(s)
Electrones , Rayos Láser , Cristalografía por Rayos X , Radiografía , Rayos X
6.
Acta Crystallogr D Struct Biol ; 77(Pt 10): 1218-1232, 2021 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-34605426

RESUMEN

Careful selection of photocaging approaches is critical to achieve fast and well synchronized reaction initiation and perform successful time-resolved structural biology experiments. This review summarizes the best characterized and most relevant photocaging groups previously described in the literature. It also provides a walkthrough of the essential factors to consider in designing a suitable photocaged molecule to address specific biological questions, focusing on photocaging groups with well characterized spectroscopic properties. The relationships between decay rates (k in s-1), quantum yields (ϕ) and molar extinction coefficients (ϵmax in M-1 cm-1) are highlighted for different groups. The effects of the nature of the photocaged group on these properties is also discussed. Four main photocaging scaffolds are presented in detail, o-nitrobenzyls, p-hydroxyphenyls, coumarinyls and nitrodibenzofuranyls, along with three examples of the use of this technology. Furthermore, a subset of specialty photocages are highlighted: photoacids, molecular photoswitches and metal-containing photocages. These extend the range of photocaging approaches by, for example, controlling pH or generating conformationally locked molecules.


Asunto(s)
Luz , Procesos Fotoquímicos , Proteínas/química , Difracción de Rayos X/métodos , Animales , Humanos , Conformación Proteica
7.
Acta Crystallogr D Struct Biol ; 77(Pt 2): 194-204, 2021 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-33559608

RESUMEN

The emergence of X-ray free-electron lasers has led to the development of serial macromolecular crystallography techniques, making it possible to study smaller and more challenging crystal systems and to perform time-resolved studies on fast time scales. For most of these studies the desired crystal size is limited to a few micrometres, and the generation of large amounts of nanocrystals or microcrystals of defined size has become a bottleneck for the wider implementation of these techniques. Despite this, methods to reliably generate microcrystals and fine-tune their size have been poorly explored. Working with three different enzymes, L-aspartate α-decarboxylase, copper nitrite reductase and copper amine oxidase, the precipitating properties of ammonium sulfate were exploited to quickly transition from known vapour-diffusion conditions to reproducible, large-scale batch crystallization, circumventing the tedious determination of phase diagrams. Furthermore, the specific ammonium sulfate concentration was used to fine-tune the crystal size and size distribution. Ammonium sulfate is a common precipitant in protein crystallography, making these findings applicable to many crystallization systems to facilitate the production of large amounts of microcrystals for serial macromolecular crystallography experiments.


Asunto(s)
Cristalografía por Rayos X/métodos , Sustancias Macromoleculares/química , Proteínas/química , Sulfato de Amonio/química
8.
Lab Chip ; 21(24): 4831-4845, 2021 12 07.
Artículo en Inglés | MEDLINE | ID: mdl-34821226

RESUMEN

The practice of serial X-ray crystallography (SX) depends on efficient, continuous delivery of hydrated protein crystals while minimizing background scattering. Of the two major types of sample delivery devices, fixed-target devices offer several advantages over widely adopted jet injectors, including: lower sample consumption, clog-free delivery, and the ability to control on-chip crystal density to improve hit rates. Here we present our development of versatile, inexpensive, and robust polymer microfluidic chips for routine and reliable room temperature serial measurements at both synchrotrons and X-ray free electron lasers (XFELs). Our design includes highly X-ray-transparent enclosing thin film layers tuned to minimize scatter background, adaptable sample flow layers tuned to match crystal size, and a large sample area compatible with both raster scanning and rotation based serial data collection. The optically transparent chips can be used both for in situ protein crystallization (to eliminate crystal handling) or crystal slurry loading, with prepared samples stable for weeks in a humidified environment and for several hours in ambient conditions. Serial oscillation crystallography, using a multi-crystal rotational data collection approach, at a microfocus synchrotron beamline (SSRL, beamline 12-1) was used to benchmark the performance of the chips. High-resolution structures (1.3-2.7 Å) were collected from five different proteins - hen egg white lysozyme, thaumatin, bovine liver catalase, concanavalin-A (type VI), and SARS-CoV-2 nonstructural protein NSP5. Overall, our modular fabrication approach enables precise control over the cross-section of materials in the X-ray beam path and facilitates chip adaption to different sample and beamline requirements for user-friendly, straightforward diffraction measurements at room temperature.


Asunto(s)
COVID-19 , Microfluídica , Animales , Bovinos , Cristalografía por Rayos X , Diseño de Equipo , Humanos , Polímeros , SARS-CoV-2 , Temperatura
9.
Acta Crystallogr D Struct Biol ; 76(Pt 4): 340-349, 2020 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-32254058

RESUMEN

Despite the great strides made in the field of single-particle cryogenic electron microscopy (cryo-EM) in microscope design, direct electron detectors and new processing suites, the area of sample preparation is still far from ideal. Traditionally, sample preparation involves blotting, which has been used to achieve high resolution, particularly for well behaved samples such as apoferritin. However, this approach is flawed since the blotting process can have adverse effects on some proteins and protein complexes, and the long blot time increases exposure to the damaging air-water interface. To overcome these problems, new blotless approaches have been designed for the direct deposition of the sample on the grid. Here, different methods of producing droplets for sample deposition are compared. Using gas dynamic virtual nozzles, small and high-velocity droplets were deposited on cryo-EM grids, which spread sufficiently for high-resolution cryo-EM imaging. For those wishing to pursue a similar approach, an overview is given of the current use of spray technology for cryo-EM grid preparation and areas for enhancement are pointed out. It is further shown how the broad aspects of sprayer design and operation conditions can be utilized to improve grid quality reproducibly.


Asunto(s)
Microscopía por Crioelectrón/métodos , Manejo de Especímenes/métodos
10.
Rev Sci Instrum ; 91(8): 085108, 2020 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-32872940

RESUMEN

Free liquid jets are a common sample delivery method in serial femtosecond x-ray (SFX) crystallography. Gas dynamic virtual nozzles (GDVNs) use an outer gas stream to focus a liquid jet down to a few micrometers in diameter. Such nozzles can be fabricated through various methods (capillary grinding, soft lithography, digital light processing, and two-photon polymerization) and materials, such as glass, polydimethylsiloxane, and photosensitive polyacrylates. Here, we present a broadly accessible, rapid prototyping laser ablation approach to micromachine solvent-resistant and inert Kapton polyimide foils with highly reproducible geometric features that result in 3D flow-focused GDVNs suitable for crystallography experiments at synchrotrons and free-electron laser facilities.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA