Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Magn Reson Imaging ; 53(6): 1926-1937, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33368773

RESUMEN

Current contrast-enhanced magnetic resonance angiography (MRA) and non-contrast-enhanced balanced steady-state free precession (bSSFP) MRA cause susceptibility artifacts from metallic devices in assessing endovascular visceral-artery interventions. The aims of this study are to investigate and compare image quality (IQ) and susceptibility artifacts of three-dimensional (3D) ultrashort echo time (UTE) time-spatial labeling inversion pulse (Time-SLIP) with those of 3D bSSFP Time-SLIP and to assess denoising deep learning reconstruction (dDLR) for the improvement of the signal-to-noise ratio (SNR) in 3D UTE with sparse sampling in phantoms and human subjects. This is a prospective type of study. Pulsatile glycerin-water flow phantom with platinum-tungsten-alloy coil, stainless-steel, nitinol, and cobalt-alloy stents were used. Ten healthy volunteers (seven males) and three patients (two males) were included in this study. 3D UTE Time-SLIP and 3D bSSFP Time-SLIP at 3T were used. The phantom-based study compared the signal-intensity ratio of the device levels (SRdevice ) and distal segments (SRdistal ) to the proximal segments. The volunteer-based study measured SNR, contrast ratio (CR), and IQ. The patient study evaluated local artifacts from metallic devices. Statistical tests included paired t-tests, Wilcoxon-signed rank tests, and Kruskal-Wallis tests. In the phantom-based study, SRdevice was small with UTE Time-SLIP, except the stainless-steel stent. SRdistal was greater (49.1%-90.4%) on bSSFP images than UTE images (-11.1% to 9.6%). Among volunteers, dDLR in UTE images improved SNR (p < 0.05) and IQ (p < 0.05), but CR was unaffected. UTE Time-SLIP showed inferior SNR and IQ than bSSFP Time-SLIP in images with and without dDLR (p < 0.05 for each). However, among patients, UTE Time-SLIP showed reduced metal artifacts compared to bSSFP Time-SLIP. Irrespective of the lower SNR and IQ of 3D UTE Time-SLIP than those of 3D bSSFP Time-SLIP, the former appeared to better depict flow after stenting or coiling. This indicates the potential of 3D UTE Time-SLIP to provide suitable diagnostic images of target vessels. dDLR improved SNR with reducing artifacts related to radial sampling, while maintaining the contrast. LEVEL OF EVIDENCE: 2. TECHNICAL EFFICACY STAGE: 2.


Asunto(s)
Aprendizaje Profundo , Angiografía por Resonancia Magnética , Arterias , Artefactos , Humanos , Imagenología Tridimensional , Imagen por Resonancia Magnética , Masculino , Estudios Prospectivos
2.
Org Biomol Chem ; 18(2): 230-236, 2020 01 02.
Artículo en Inglés | MEDLINE | ID: mdl-31681919

RESUMEN

Calix[3]aramide-based cylindrical macrocycles were synthesized by the one-step amide coupling reaction of a monomer containing two meta-alkylaminobenzoic acid units linked by para-phenylene bridges. The major products included a meso-form and an enantiomeric pair, with stereochemistry derived from the direction of the amide bonds and their fixed conformation. Mirror-image ECD, VCD, and CPL spectra were observed in the enantiomeric pair and the absolute structure was determined by comparing measured and calculated ECD and VCD spectra.

3.
RSC Adv ; 10(57): 34549-34555, 2020 Sep 16.
Artículo en Inglés | MEDLINE | ID: mdl-35514401

RESUMEN

Calix[3]aramide-based macrocycles 1 were successfully synthesized by a Glaser coupling reaction of two meta-calix[3]aramide moieties that have three ethynyl groups. The obtained macrocycles have stereoisomers: an enantiomeric pair and a meso form based on a combination of amide bond directions in the calix[3]aramide moieties at both ends of the molecule. Characteristic absorption spectra derived from the 1,4-diphenylbutadiyne structure were observed, while their ECD spectra were mirror-images. Single-crystal X-ray analysis revealed that each stereoisomer had a cylindrical rigid shape, and the absolute structure of the chiral-form was also assigned by comparing the Flack parameters. Mirror-image VCD spectra were observed for the enantiomeric chiral forms, and a VCD signal pattern of one enantiomer corresponded to that predicted by the relationship between the dihedral angle of the pair of C[double bond, length as m-dash]O groups.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA