Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Int J Psychol ; 56(4): 566-576, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33236341

RESUMEN

Using data from a computer-based formative feedback system, we compare learning gains in the 8 weeks of school closures related to the COVID-19 pandemic in Switzerland with learning gains in the 8 weeks before these school closures. The school performance in mathematics and language of N = 28,685 pupils is modelled in second-order piecewise latent growth models with strict measurement invariance for the two periods under investigation. While secondary school pupils remain largely unaffected by the school closures in terms of learning gains, for primary school pupils learning slows down and at the same time interindividual variance in learning gains increases. Distance learning arrangements seem an effective means to substitute for in-person learning, at least in an emergency situation, but not all pupils benefit to the same degree.


Asunto(s)
COVID-19/epidemiología , COVID-19/psicología , Educación a Distancia/tendencias , Escolaridad , Aprendizaje , Instituciones Académicas/tendencias , Rendimiento Académico/psicología , Rendimiento Académico/tendencias , Adolescente , COVID-19/prevención & control , Niño , Educación a Distancia/métodos , Femenino , Humanos , Aprendizaje/fisiología , Masculino , Pandemias , Suiza/epidemiología
2.
Child Dev ; 90(6): e745-e762, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31710094

RESUMEN

Thriving is a developmental process that is shaped by previous and current interactions within developmental contexts. We hypothesized that academic performance in the school context will positively predict thriving in young adulthood. Data of N = 2,043 students from Zurich were assessed with standardized tests in Grades 1, 3, 6, and 9. Results showed that a stronger increase in academic performance significantly predicted thriving at age 20, even after statistically controlling for various covariates. Further analyses showed that school bonding might represent a mediating link between the academic performance and thriving. We argue that although schools can be considered the most widespread and intensive "youth development program" of sorts, their role for thriving has been largely neglected in developmental science.


Asunto(s)
Rendimiento Académico/estadística & datos numéricos , Desarrollo Humano , Apego a Objetos , Instituciones Académicas , Estudiantes/estadística & datos numéricos , Adolescente , Adulto , Niño , Femenino , Humanos , Estudios Longitudinales , Masculino , Adulto Joven
3.
BMC Health Serv Res ; 18(1): 183, 2018 03 15.
Artículo en Inglés | MEDLINE | ID: mdl-29544484

RESUMEN

BACKGROUND: In Switzerland, the issue of young carers and young adult carers - young people under the age of 18 and 24 respectively, who take on significant or substantial caring tasks and levels of responsibility that would usually be associated with an adult - has not been researched before. The number of these younger carers is unknown, as is the extent and kind of their caring activities and the outcomes for their health, well-being, psycho-social development, education, transitions to adulthood, future employability and economic participation. METHODS: The project is comprised of three stages: 1. A national Swiss-wide online survey to examine awareness of the issue of younger carers amongst professional populations in the education, health and social services sectors; 2. An online survey of 4800 Swiss pupils in schools using standardised instruments to identify the proportion and characteristics of pupils who are carers; and 3. Semi-structured interviews with 20 families comprising family members with care needs and younger carers, to consolidate and validate the other stages of the study; and to hear directly from care-dependent family members and younger carers about their experiences of the issues identified in the surveys and in previous published research. DISCUSSION: The needs of younger carers and their ill and disabled family members in Switzerland have not been systematically investigated. This will be the first study in the country to investigate these issues and to develop evidence-based recommendations for policy and practice, drawing also on international research. The present study therefore fills an important national and international research gap. It will collect important data on the awareness, extent, kind and impact of caring amongst children and young people in Switzerland, and cross-link these findings with robust evidence from other countries. The study will reveal (a) the extent of awareness of the issue of young carers amongst medical, social, health, educational, and other groups in Switzerland; (b) the proportion and number of young carers amongst a normative child population, and what these young carers 'do' in terms of their caring roles; and


Asunto(s)
Cuidadores/estadística & datos numéricos , Adolescente , Factores de Edad , Niño , Humanos , Investigación Cualitativa , Encuestas y Cuestionarios , Suiza , Adulto Joven
4.
IEEE Trans Med Imaging ; 39(4): 997-1007, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31484112

RESUMEN

In magnetic resonance imaging, the use of array detection and the number of detector elements have seen a steady increase over the past two decades. As a result, per-channel analog connection via long coaxial cable, as commonly used, poses an increasing challenge in terms of handling, safety, and coupling among cables. This situation is exacerbated when complementary recording of radiofrequency transmission or NMR-based magnetic field sensing further add to channel counts. A generic way of addressing this trend is the transition to digital signal transmission, enabled by digitization and first-level digital processing close to detector coils and sensors in the magnet bore. The foremost challenge that comes with this approach is to achieve high dynamic range, linearity, and phase stability despite interference by strong static, audiofrequency, and radiofrequency fields. The present work reports implementation of a 16-channel in-bore receiver, performing signal digitization and processing with subsequent optical transmission over fiber. Along with descriptions of the system design and construction, performance evaluation is reported. The resulting device is fully MRI compatible providing practically equal performance and signal quality compared to state-of-the-art RF digitizers operating outside the magnet. Its use is demonstrated by examples of head imaging and magnetic field recording.


Asunto(s)
Imagen por Resonancia Magnética/instrumentación , Procesamiento de Señales Asistido por Computador/instrumentación , Encéfalo/diagnóstico por imagen , Diseño de Equipo , Humanos , Campos Magnéticos , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen
5.
Ultrasound Med Biol ; 34(7): 1186-90, 2008 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-18294756

RESUMEN

Quantitative ultrasound (QUS) measurements can be used to estimate osteoporotic fracture risk. The commonly used variables are the speed of sound (SOS) and the frequency dependent sound attenuation (broadband ultrasound attenuation, [BUA]) of a wave propagating through the bone, preferably the calcaneus. The technology, so far, is less suitable for direct measurement in vivo at the spine or the femur for prediction of bone mineral density (BMD) or fracture risk at the main osteoporotic fracture sites. To improve the clinical performance of QUS, we built a device for direct QUS measurements at the human femur in vivo. In vivo images of ultrasound transmission at one of the main fracture sites, the proximal femur, could be acquired. The estimated precision of SOS measurements of 0.5% achieved at the femur is comparable with the precision of peripheral QUS devices.


Asunto(s)
Fémur/diagnóstico por imagen , Osteoporosis/diagnóstico por imagen , Densidad Ósea , Estudios de Factibilidad , Fémur/fisiopatología , Fracturas de Cadera/etiología , Humanos , Osteoporosis/complicaciones , Osteoporosis/fisiopatología , Medición de Riesgo , Transductores , Ultrasonografía
6.
Front Psychol ; 9: 2245, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30515119

RESUMEN

Formative assessments in schools have the potential to improve students' learning outcomes and self-regulation skills; they make learning visible and provide evidence-based guidelines for setting up and pursuing individual learning goals. With the recent introduction of the computer-based formative assessment systems for the educational contexts, there is much hope that such systems will provide teachers and students with valuable information to guide the learning process without taking much time from teaching and learning to spend on generating, evaluating and interpreting assessments. In this paper, we combine the theoretical and applied perspectives by addressing (a) the epistemological aspects of the formative assessment, with an emphasis on data collection, model building, and interpretation; (b) the methodological challenges of providing feedback in the context of instruction in the classroom; and (c) practical requirements for and related challenges of setting up and delivering the assessment system to a large number of students. In the epistemological section, we develop and explicate the interpretive argument of formative assessment and discuss the challenges of obtaining data with high validity. From the methodological perspective, we argue that computer-based formative assessment systems are generally superior to the traditional methods of providing feedback in the classroom, as they better allow supporting inferences of the interpretive argument. In the section on practical requirements, we first introduce an existing computer-based formative assessment system, as a case in point, for discussing related practical challenges. Topics covered in this section comprise the specifications of assessment content, the calibration and maintenance of the item bank, challenges concerning teachers' and students' assessment literacy, as well as ethical and data-protection requirements. We conclude with an outlook on possible future directions for computer-based formative assessment systems and the field in general.

7.
Am J Intellect Dev Disabil ; 122(6): 476-491, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-29115877

RESUMEN

The phonological awareness skills of 7- to 8-year-old children with intellectual disability (ID) were compared to those of 4- to 5-year-old typically developing children who were matched for early reading skills, vocabulary, and gender. Globally, children with ID displayed a marked weakness in phonological awareness. Syllable blending, syllable segmentation, and first phoneme detection appeared to be preserved. In contrast, children with ID showed a marked weakness in rhyme detection and a slight weakness in phoneme blending. Two school years later, these deficits no longer remained. Marked weaknesses appeared in phoneme segmentation and first/last phoneme detection. The findings suggest that children with ID display an atypical pattern in phonological awareness that changes with age. The implications for practice and research are discussed.


Asunto(s)
Discapacidad Intelectual/fisiopatología , Desarrollo del Lenguaje , Fonética , Lectura , Factores de Edad , Niño , Preescolar , Femenino , Estudios de Seguimiento , Humanos , Masculino
8.
Swiss Med Wkly ; 143: w13861, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24363082

RESUMEN

Ultrasound (US) has become a useful tool in the detection of early disease, differential diagnosis, guidance of treatment decisions and treatment monitoring of rheumatoid arthritis (RA). In 2008, the Swiss Sonography in Arthritis and Rheumatism (SONAR) group was established to promote the use of US in inflammatory arthritis in clinical practice. A scoring system was developed and taught to a large number of Swiss rheumatologists who already contributed to the Swiss Clinical Quality Management (SCQM) database, a national patient register. This paper intends to give a Swiss consensus about best clinical practice recommendations for the use of US in RA on the basis of the current literature knowledge and experience with the Swiss SONAR score. Literature research was performed to collect data on current evidence. The results were discussed among specialists of the Swiss university centres and private practice, following a structured procedure. Musculoskelatal US was found to be very helpful in establishing the diagnosis and monitoring the evolution of RA, and to be a reliable tool if used by experienced examiners. It influences treatment decisions such as continuing, intensifying or stepping down therapy. The definite modalities of integrating US into the diagnosis and monitoring of RA treatments will be defined within a few years. There are, however, strong arguments to use US findings as of today in daily clinical care. Some practical recommendations about the use of US in RA, focusing on the diagnosis and the use of the SONAR score, are proposed.


Asunto(s)
Artritis Reumatoide/diagnóstico por imagen , Articulaciones/diagnóstico por imagen , Sinovitis/diagnóstico por imagen , Antirreumáticos/uso terapéutico , Artritis Gotosa/diagnóstico , Artritis Gotosa/diagnóstico por imagen , Artritis Reumatoide/diagnóstico , Artritis Reumatoide/tratamiento farmacológico , Diagnóstico Diferencial , Humanos , Guías de Práctica Clínica como Asunto , Suiza , Sinovitis/diagnóstico , Resultado del Tratamiento , Ultrasonografía
9.
Artículo en Inglés | MEDLINE | ID: mdl-18599408

RESUMEN

Quantitative ultrasound (QUS) at the calcaneus has similar power as a bone mineral density (BMD)- measurement using DXA for the prediction of osteoporotic fracture risk. Ultrasound equipment is less expensive than DXA and free of ionizing radiation. As a mechanical wave, QUS has the potential of measuring different bone properties than dual X-ray absorptiometry (DXA,) which depends on X-ray attenuation and might be developed into a tool of comprehensive assessment of bone strength. However, site-specific DXA at the proximal femur shows best performance in the prediction of hip fractures. To combine the potential of QUS with measurements directly at the femur, we developed a device for in vivo QUS measurements at this site. Methods comprise ultrasound transmission through the bone, reflection from the bone surface, and backscatter from the inner trabecular structure. The complete area of the proximal femur can be scanned except at the femoral head, which interferes with the ilium. To avoid edge artifacts, a subregion of the proximal femur in the trochanteric region was selected as measurement region. First, in vivo measurements demonstrate a good signal to noise ratio and proper depiction of the proximal femur on an attenuation image. Our results demonstrate the feasibility of in vivo measurements. Further improvements can be expected by refinement of the scanning technique and data evaluation method to enhance the potential of the new method for the estimation of bone strength.


Asunto(s)
Densidad Ósea , Densitometría/instrumentación , Fémur/diagnóstico por imagen , Fémur/fisiopatología , Ultrasonografía/instrumentación , Densitometría/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Interpretación de Imagen Asistida por Computador/instrumentación , Interpretación de Imagen Asistida por Computador/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Evaluación de la Tecnología Biomédica , Ultrasonografía/métodos
10.
J Am Coll Cardiol ; 48(10): 2070-6, 2006 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-17112996

RESUMEN

OBJECTIVES: The purpose of this study was to develop a transesophageal probe that: 1) enables on-line representation of the spatial structures of the heart, and 2) enables navigation of medical instruments. BACKGROUND: Whereas transthoracic real-time 3-dimensional (3D) echocardiography could recently be implemented, there is still no corresponding transesophageal system. Transesophageal real-time 3D echocardiography would have great potential for numerous clinical applications, such as navigation of catheters. METHODS: The newly developed real-time 3D system is based on a transesophageal probe in which multiple transducers are arranged in an interlaced pattern on a rotating cylinder. This enables continuous recording of a large echo volume of 70 mm in length and a sector angle of 120 degrees . The presentation of the volume-reconstructed data is made with a time lag of <100 ms. The frame rate is up to 20 Hz. In addition to conventional imaging, the observer can obtain a stereoscopic image of the structures examined with red/blue goggles. RESULTS: It was shown in vitro on ventricle- and aorta-form agar models and in vivo that the system enables excellent visualization of the 3D structures. Shape, spatial orientation, and the navigation of various catheters (e.g., EPS-catheter, Swan-Ganz-catheter), stents, or atrial septal defect occluders could be recorded on-line and stereoscopically depicted. The size of the echo sector enables a wide field of view without changing the position of the probe. CONCLUSIONS: Transesophageal real-time 3D echocardiography can be technically realized with the system presented here. The in vitro and in vivo studies show particularly the potential for navigation in the heart and large vessels on the basis of stereoscopic images.


Asunto(s)
Sistemas de Computación , Ecocardiografía Tridimensional/métodos , Ecocardiografía Transesofágica/métodos , Aorta/diagnóstico por imagen , Ecocardiografía Tridimensional/instrumentación , Ecocardiografía Transesofágica/instrumentación , Ventrículos Cardíacos , Humanos , Técnicas In Vitro , Modelos Cardiovasculares
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA