Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Asunto de la revista
Intervalo de año de publicación
1.
Eur J Orthop Surg Traumatol ; 34(1): 353-361, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37530905

RESUMEN

BACKGROUND: The management of failed tibial fracture fixation remains a challenge for orthopaedic surgeons. This study investigate the utility and outcomes of circular external fixation in the management of failed internal fixation of tibial fractures. METHODS: Retrospective review of a prospectively collected database of a complex limb reconstruction unit at a major trauma centre was done during December 2022. Patients with failed internal fixation of tibial fracture who underwent revision surgery with circular external fixation frame were included. RESULTS: 20 patients with a mean age of 47.8 ± 16.5 years (range: 15-69) were included. Fourteen (70.0%) patients had failed plate and screws fixations, and the remaining six (30.0%) failed intramedullary nail fixation. The most common indication for revision surgery was development of early postoperative surgical site infection (5 patients; 25.0%). The mean duration of frame treatment was 199.5 ± 80.1 days (range = 49-364), while the mean follow-up duration following frame removal was 3.2 ± 1.8 years (range = 2-8). The overall union rate in this series was 100%; and all infected cases had complete resolution from infection. The total number of complications was 11, however, only two complications required surgical intervention. The most common complications reported were pin site infection (6; 30.0%) and limb length discrepancy of 2 cm (2; 10.0%). CONCLUSIONS: Circular external fixation is a reliable surgical option in the treatment of failed internal fixation of tibia fractures. This technique can provide limb salvage in complex infected and noninfected cases with a high union rate and minimal major complications.


Asunto(s)
Tibia , Fracturas de la Tibia , Humanos , Adulto , Persona de Mediana Edad , Tibia/cirugía , Fijación de Fractura/efectos adversos , Fijación de Fractura/métodos , Fijadores Externos , Resultado del Tratamiento , Fijación Interna de Fracturas/efectos adversos , Fijación Interna de Fracturas/métodos , Fracturas de la Tibia/cirugía , Estudios Retrospectivos
2.
Eur J Orthop Surg Traumatol ; 33(6): 2625-2632, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36774409

RESUMEN

PURPOSE: Reconstructive surgery for complex knee problems is limited and challenging. The aim of this study is to report the technique, outcomes and complications of circular external fixation for knee fusion in complex indications. METHODS: Retrospective review of a prospectively collected database of a complex limb reconstruction unit was done during December 2022. Patients with complex knee problems who underwent knee fusion with circular external fixator were included. RESULTS: Fourteen patients met the inclusion criteria. The mean age of the patients was 63 ± 16.8 years. Deep infection was the indication for surgery in 11 patients (78.5%), of which 10 cases were related to previously failed revision arthroplasty. The mean duration of treatment in frame was 13 ± 4.1 months, while the mean follow-up duration following frame removal was 7.1 ± 4.2 years. Fusion was achieved in 13 patients (92.9%). The most common complication was pin site infection (6; 42.9%), of which three (21.4%) required pin/wire revision. One (7.1%) patient had fracture at the fusion site following frame removal that was treated with reapplication of the frame. CONCLUSION: Knee fusion using circular external fixation is a reliable surgical option for complex knee problems especially in infected failed revision total knee replacements.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Infecciones Relacionadas con Prótesis , Humanos , Persona de Mediana Edad , Anciano , Articulación de la Rodilla/cirugía , Fijadores Externos/efectos adversos , Infecciones Relacionadas con Prótesis/etiología , Infecciones Relacionadas con Prótesis/cirugía , Fijación de Fractura/efectos adversos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Estudios Retrospectivos , Artrodesis/efectos adversos , Artrodesis/métodos , Resultado del Tratamiento
3.
Strategies Trauma Limb Reconstr ; 19(1): 40-44, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38752187

RESUMEN

Introduction: The decision to use circular frame fixation for lower limb trauma, or elective deformity correction, often accompanies the assertion that the patient will be able to fully weight-bear through the limb immediately following surgery. Materials and methods: About 53 patients underwent retrospective review. Included in the study were current attendees of adult specialist physiotherapy, following circular frame application to the lower leg at our Institution between August 2018 and January 2020. Cases with incomplete data, cases given postoperative status of non-weight-bearing, those with physiotherapy follow-up conducted elsewhere, or cases of polytrauma were excluded from the study.Weight-bearing assessment and rehabilitation supervision were at the discretion of the physiotherapy team. The clinical concept of 'full weight-bearing' is poorly defined, but was documented in the context of displaying a stable gait using elbow crutches and subsequently without walking aids. Comparative data was analysed using an unpaired, two-tailed Welch's t-test. Results: Mean postoperative time to full weight-bearing using crutches was 28.3 days (0-159) (n = 40).Mean postoperative time to independent full weight-bearing with no walking aids was 230.6 days (35-393), or 7.1 months (0-12) (n= 34).No significant differences were seen between:Frames for open injuries (n= 5) vs closed injuries (n = 17; p > 0.4).Joint-spanning constructs (n= 18) vs non-spanning constructs (n = 21; p > 0.6), orTreatment of intra-articular injuries (n = 14) vs extra-articular injuries (n = 17; p > 0.2).Interpretation of these results should be made with caution due to sample size. Conclusion: The ability to permit patients to fully weight-bear immediately after surgery is often a distinct advantage of the circular frame over other fixation modalities, for a variety of indications. However, it does not follow that patients are capable of doing so; there is a long dependency on walking aids. This would appear to be the case irrespective of open/closed injuries, intra-/extra-articular injuries, or the use of a spanning construct across the knee or ankle. How to cite this article: Craig A, Barron E, Sharma H, et al. Do Patients Achieve "Full Weight-bearing" Immediately Following Application of Circular Frame Fixation of the Lower Limb? Strategies Trauma Limb Reconstr 2024;19(1):40-44.

4.
J Orthop ; 54: 148-157, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38586600

RESUMEN

Background: Varus deformity is common in medial compartment knee osteoarthritis (OA). This coronal plane malalignment is compensated for by static and dynamic adjustments in the position of the adjacent joints, principally in the hindfoot & ankle. Varus knee OA can be treated in selected patients with high tibial osteotomy (HTO) and stabilised with a fixed angle plate or circular frame, which may reverse these compensatory adjustments. The aim of this systematic review is to determine the evidence available for static and dynamic compensations with the main objectives being to improve deformity planning and optimise patient outcomes. Method: A systematic review with meta-analysis was designed using the PRISMA template to meet the research aims & objectives. Results: A total of 1006 patients (1020 knees) with acombined mean age of 54.5 years, female:male ratio of 0.9:1 were extracted from 19 included studies. The methodologies of the majority of studies were at high risk of bias according to the Newcastle-Ottawa Scale demonstrating significant heterogeneity. The combined mean change in the HKA axis was 7.7°; MPTA 7.4°; TT, 0.21°; TI 4.56° & AJLO 4° valgus. Preoperative hindfoot valgus compensation reverts towards neutral post-HTO. There is limited evidence available for a direct relationship between static alignment and dynamic gait parameters. Conclusions: An inverse relationship between ankle and hindfoot alignment in varus deformity of the knee forms the basis of this compensation theory. In cases with a stiff hindfoot which may not revert postoperatively, the reconstructive orthopaedic surgeon may consider angulation with translation HTO, in order to optimise joint alignment and minimise transference of symptoms to the foot and ankle.

5.
Injury ; 54(3): 996-1003, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36682926

RESUMEN

INTRODUCTION: Traditional Ilizarov and hexapod frames have different biomechanical properties and there is limited literature regarding their effect on time to fracture union or time to frame removal. METHODS: Tibial fractures managed with a circular frame at a tertiary limb reconstruction referral centre between 2011 and 2018 were retrospectively identified from a prospectively maintained database. They were classified into three treatment groups; Ilizarov style, Taylor Spatial Frame (TSF) and TrueLok Hex (TL-Hex). Data were extracted from electronic patient records and digital radiographs. The primary outcome was time to frame removal, which was seen as an indicator of clinical and radiological fracture union. Odds ratios were calculated with the clinical significance set at 30 days. RESULTS: 274 patients (median age 49 years, 36% female) were included in the analysis. 8.4% Ilizarov, 10.5% TSF and 13.5% TL-Hex frames required further surgery to aid fracture healing (p = 0.38). 30% of patients had open fractures. Median time to removal for Ilizarov, TSF & TL Hex frames was 167, 198 and 185 days respectively. There was a significant difference between Ilizarov and hexapod frames. Both TSF (OR 2.2, p<0.003) and TL-Hex (OR 1.8, p<0.04) had a significantly increased time to removal of 30 days or more compared with Ilizarov frames.The time to frame removal in metaphyseal fractures was significantly shorter for Ilizarov frame fixation than hexapod frames (p = 0.04). Open fractures were significantly more likely to require at least 30 days extra time to removal than closed fractures (OR 3.3, p<0.001). There was no significant difference in the time to frame removal between fracture location, age or sex. CONCLUSION: Ilizarov frames have demonstrated a reduced time to frame removal in the management of tibial fractures than hexapod frames. Differences in the time to frame removal, an indicator of time to fracture union, may be due to the different mechanical properties of the frame, or early disruption of the fracture haematoma through secondary frame manipulation and fracture reduction, increased proportion of metaphyseal fractures treated with Ilizarov, or patient selection. The healing time was comparable across the tibia. Pooled meta-analyses may be able to further quantify these associations.


Asunto(s)
Fracturas Abiertas , Técnica de Ilizarov , Fracturas de la Tibia , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fijadores Externos , Fracturas Abiertas/cirugía , Estudios Retrospectivos , Tibia , Fracturas de la Tibia/cirugía , Resultado del Tratamiento
6.
Foot Ankle Int ; 44(5): 403-414, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36942403

RESUMEN

BACKGROUND: Circular frames for ankle fusion are reserved for complex clinical scenarios. The literature is heterogenous and conflicting. We aim to present the indications and outcomes of this procedure. METHODS: A retrospective cohort study based on a prospective database of frame surgeries performed in a tertiary institution. Inclusion criteria were patients undergoing complex ankle fusion with circular frames between 2005 and 2020, with a minimum 12-month follow-up. Data were collected on patient demographics, surgical indications, comorbidities, surgical procedures, external fixator time (EFT), length of stay (LOS), radiologic and clinical outcomes, and adverse events. Factors influencing radiologic and clinical outcomes were analyzed. RESULTS: 47 patients were included, with a median follow-up of 30 months (interquartile range [IQR] 20-40). The median age at time of surgery was 63.5 years (IQR 58-71). Patients had a median of 2 previous surgeries (IQR 1-3). The median LOS was 8.5 days, and median EFT was 237 days (IQR 166-280). Simultaneous limb lengthening (median 3.3 cm, IQR 1.9-3.5) was performed in 11 patients, increasing the EFT by a mean of 4 months. Primary and final union rates were 91.5% and 95.7%, respectively. At last follow-up, ASAMI bone scores were excellent or good in 87.2%. ASAMI functional scores were good in 79.1%. Patient satisfaction was 83.7%. In addition, 97.7% of patients experienced adverse events, most commonly pin-site related, with major complications in 30.2% and reoperations in 60.5%. There were 3 amputations. Adverse events were associated with increased age, poor soft tissue condition, severe deformities, subtalar fusions, peripheral neuropathy, peripheral vascular disease, and prolonged EFT. CONCLUSION: Complex ankle fusion using circular frames can achieve good outcomes, however time in frame may be prolonged with a high rate of adverse events. Identified risk factors for poorer outcomes should be considered in patient counselling and prognostication. LEVEL OF EVIDENCE: Level III, prognostic.


Asunto(s)
Articulación del Tobillo , Satisfacción del Paciente , Humanos , Persona de Mediana Edad , Anciano , Estudios Retrospectivos , Articulación del Tobillo/cirugía , Tobillo/cirugía , Comorbilidad , Artrodesis/métodos , Resultado del Tratamiento
7.
Strategies Trauma Limb Reconstr ; 17(2): 88-91, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35990185

RESUMEN

Aim: Superficial pin site infection is a common problem associated with external fixation, which has been extensively reported. However, the incidence and risk factors with regard to deep infection are rarely reported in the literature. In this study, we investigate and explore the incidence and risk factors of deep infection following circular frame surgery. For the purpose of this study, deep infection was defined as persistent discharge or collection for which surgical intervention was recommended. Materials and methods: This study is retrospective review of all patients who underwent frame surgery between April 1, 2015 and April 1, 2019 in our unit with a minimum of 1 year follow-up following frame removal. We recorded patient demographics, patient risk factors, trauma or elective procedure, number of days the frame was in situ, location of infection and fracture pattern. Results: Three-hundred and four patients were identified. Twenty-seven patients were excluded as they were lost to follow-up or had their primary frame surgery as a treatment for infection. This provided us with 277 patients for analysis. The mean age was 47 years (range: 9-89 years), the male to female ratio was 1.5:1, and 80% were trauma frames. Thirteen patients (4.69%) developed deep infection, and all occurred in trauma patients. Of the 13 patients who developed deep infection, 4 had infection before frame removal, and infection occurred in 9 after frame removal. Deep infections occurred in 8 patients within a year of frame removal and in one patient between 1 and 2 years of frame removal.Within the 13 frame procedures for trauma, 12 were periarticular multi-fragmentary fractures, 3 of which were open, and the remaining were an open diaphyseal fracture. The periarticular fractures were more likely to develop deep infection than diaphyseal fractures (p = 0.033). Twelve patients (out of 13) also had concurrent minimally invasive internal fixation with screws in very close proximity of the wires. Conclusion: The rate of deep infection following circular frame surgery appears to be low. Pooled, multi-centre data would be required to analyse risk factors; however, multi-fragmentary, periarticular fracture and the requirement for additional internal fixation appear to be an associated factor. How to cite this article: Ting J, Moulder E, Muir R, et al. The Incidence of Deep Infection Following Lower Leg Circular Frame Fixation with Minimum of 1-year Follow-up from Frame Removal. Strategies Trauma Limb Reconstr 2022;17(2):88-91.

8.
Bone Jt Open ; 3(5): 359-366, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35491551

RESUMEN

AIMS: The timing of when to remove a circular frame is crucial; early removal results in refracture or deformity, while late removal increases the patient morbidity and delay in return to work. This study was designed to assess the effectiveness of a staged reloading protocol. We report the incidence of mechanical failure following both single-stage and two stage reloading protocols and analyze the associated risk factors. METHODS: We identified consecutive patients from our departmental database. Both trauma and elective cases were included, of all ages, frame types, and pathologies who underwent circular frame treatment. Our protocol is either a single-stage or two-stage process implemented by defunctioning the frame, in order to progressively increase the weightbearing load through the bone, and promote full loading prior to frame removal. Before progression, through the process we monitor patients for any increase in pain and assess radiographs for deformity or refracture. RESULTS: There were 244 frames (230 patients) included in the analyses, of which 90 were Ilizarov type frames and 154 were hexapods. There were 149 frames which underwent single-stage reloading and 95 frames which underwent a two-stage reloading protocol. Mechanical failure occurred after frame removal in 13 frames (5%), which suffered refracture. There were no cases of change in alignment. There was no difference between refracture patients who underwent single-stage or two-stage reloading protocols (p = 0.772). In all, 14 patients had failure prevented through identification with the reloading protocol. CONCLUSION: Our reloading protocol is a simple and effective way to confirm the timing of frame removal and minimize the rate of mechanical failure. Similar failure rates occurred between patients undergoing single-stage and two-stage reloading protocols. If the surgeon is confident with clinical and radiological assessment, it may be possible to progress directly to stage two and decrease frame time and patient morbidity. Cite this article: Bone Jt Open 2022;3(5):359-366.

9.
J Orthop Res ; 39(12): 2615-2637, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33527485

RESUMEN

Surgical site infection in the presence of orthopedic implants poses significant healthcare and socioeconomic burden. To assess the potential of various prevention strategies against Staphylococcus-induced stainless steel-associated infections, a review of animal evidence was designed. The databases of PubMed, Embase, and CENTRAL were searched until March 10, 2020, for articles including animal models with stainless steel instrumentation and techniques to prevent Staphylococcus infection. We conducted a random-effects meta-analysis of standardized mean differences (SMD) with subgroup analysis linked to various protection strategies and we recorded complications. Quality was assessed with the SYRCLE's risk of bias tool. Twenty-five studies were included. Combined active coating (featuring organic antibacterial compound release) and degradable passive finishing (lipid- or polymer-based structure modification reducing bacterial adhesion) was favored over untreated controls (SMDs for methicillin-sensitive Staphylococcus aureus [MSSA] and methicillin-resistant Staphylococcus aureus [MRSA] were -3.46, 95% CI [-4.53 to -2.4], p < .001 [n = 4 head-to-head comparisons]; and -6.67, 95% CI [-10.53 to -3], p < .001 [n = 5 head-to-head comparisons], respectively). Systemic vitamin D supplementation and systemic antibiotic administration with or without local antibiotics demonstrated favorable outcomes against MSSA infection. On the contrary, no benefit was seen following vaccination. Of note, no side effects were documented. On the basis of data gathered from eight studies, which comprised 294 animals, a bioresorbable polymer- or lipid-based surface modification supplemented with organic coating yielded improved infection-related outcomes against MSSA and MRSA stainless steel infections, and therefore, this strategy could be further investigated in human research.


Asunto(s)
Staphylococcus aureus Resistente a Meticilina , Ortopedia , Infecciones Estafilocócicas , Animales , Antibacterianos/farmacología , Antibacterianos/uso terapéutico , Lípidos , Polímeros , Acero Inoxidable , Infecciones Estafilocócicas/tratamiento farmacológico , Staphylococcus aureus
10.
Strategies Trauma Limb Reconstr ; 16(3): 161-167, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-35111255

RESUMEN

INTRODUCTION: High-energy grade III open fractures of tibia are associated with significant complications and generate debate over the ideal fixation method. This study compares the clinical outcomes for circular frame fixation (CFF) vs intramedullary nail fixation (IMF) in grade III open tibial fractures. MATERIALS AND METHODS: Single-centre retrospective study of patients admitted from January 2008 to December 2016. All patients with grade III open diaphyseal tibial fractures (AO 42 A, B, C), treated with either CFF or IMF, were included. The primary outcome was deep bone infection (DBI). Secondary outcomes were delayed or non-union, secondary intervention, and amputation. RESULTS: A total of 48 limbs in 47 patients had CFF, and 25 limbs in 23 patients had IMF. Median time to definitive fixation was significantly longer for CFF at 9 days (IQR 3-13) compared to IMF at 1 day (IQR 0-3.5) (p <0.001). The DBI rate was significantly lower (2 vs 16%) in the CFF group (p = 0.04). There were 14 limbs (29%) with delayed or non-union in the CFF group vs 5 limbs (20%) in the IMF group. In the CFF group, significantly more limbs required bone grafting for delayed or non-union (p = 0.03). However, there was a greater proportion of limbs in the CFF group with segmental fractures or bone loss (46 vs 4%) and these high-energy fracture patterns were associated with secondary bone grafting (p = 0.005), and with delayed or non-union (p = 0.03). A subgroup analysis of patients without segmental fractures or bone loss treated with either CFF or IMF showed no significant difference in secondary bone grafting (p >0.99) and delayed or non-union rates (p = 0.72). Overall, one patient in each group went on to have an amputation. CONCLUSION: Our study found that CFF had a lower rate of DBI compared to IMF. Injuries with high-energy fracture patterns (segmental fractures or bone loss) were more likely to have delayed or non-union and require secondary bone grafting. These factors should be considered when selecting the appropriate method of definitive fixation. HOW TO CITE THIS ARTICLE: Natalwala I, Chuo CB, Shariatmadari I, et al. Outcomes and Incidence of Deep Bone Infection in Grade III Diaphyseal Open Tibial Fractures: Circular Fixator vs Intramedullary Nail. Strategies Trauma Limb Reconstr 2021;16(3):161-167.

11.
Bone Joint J ; 103-B(2): 279-285, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33517738

RESUMEN

AIMS: Pin-site infection remains a significant problem for patients treated by external fixation. A randomized trial was undertaken to compare the weekly use of alcoholic chlorhexidine (CHX) for pin-site care with an emollient skin preparation in patients with a tibial fracture treated with a circular frame. METHODS: Patients were randomized to use either 0.5% CHX or Dermol (DML) 500 emollient pin-site care. A skin biopsy was taken from the tibia during surgery to measure the dermal and epidermal thickness and capillary, macrophage, and T-cell counts per high-powered field. The pH and hydration of the skin were measured preoperatively, at follow-up, and if pin-site infection occurred. Pin-site infection was defined using a validated clinical system. RESULTS: Out of 116 patients who were enrolled in the study, 23 patients (40%) in the CHX group and 26 (44%) in the DML group had at least one bad or ugly pin-site infection. This difference was not statistically significant (p = 0.71). There was no significant relationship between pH or hydration of the skin and pin-site infection. The epidermal thickness was found to be significantly greater in patients who had a pin-site infection compared with those who did not (p = 0.01). Skin irritation requiring a change of treatment occurred in four patients (7%) using CHX, and none using DML. CONCLUSION: We found no significant difference in the incidence of pin-site infection between the CHX and DML treatment groups. Dermol appeared to offer a small but significant advantage in terms of tolerability. We did not find a significant association between patient or treatment related factors and pin-site infection. It is therefore difficult to make specific recommendations based upon these results. The use of either cleaning agent appears to be appropriate. Cite this article: Bone Joint J 2021;103-B(2):279-285.


Asunto(s)
Clavos Ortopédicos/efectos adversos , Emolientes/uso terapéutico , Fijadores Externos/efectos adversos , Fijación de Fractura/instrumentación , Cuidados Posoperatorios/métodos , Infecciones Relacionadas con Prótesis/prevención & control , Fracturas de la Tibia/cirugía , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Antiinfecciosos Locales/uso terapéutico , Clorhexidina/uso terapéutico , Femenino , Estudios de Seguimiento , Fijación de Fractura/métodos , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Infecciones Relacionadas con Prótesis/epidemiología , Método Simple Ciego , Resultado del Tratamiento , Adulto Joven
12.
J Arthroplasty ; 25(5): 692-9, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-19577886

RESUMEN

We report the outcome of 58 consecutive polished tapered stems in 47 patients younger than 50 years, with a minimum of 10 years of follow-up. No stems were revised for aseptic loosening or osteolysis. The Harris hip scores were good or excellent in 76% of the patients. There was excellent preservation of proximal bone. Despite higher patient weight and frequent previous surgery, the outcome of polished tapered stems in patients younger than 50 years is comparable to the general population undergoing total hip arthroplasty and superior to other non-polished tapered stem designs in young patients. Cup wear and cup failure were significantly worse in this group, with a higher incidence of periarticular osteolysis. Polished tapered stem designs are the benchmark for comparison to other arthroplasty options in young patients.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Cementos para Huesos , Prótesis de Cadera , Osteoartritis de la Cadera/cirugía , Adolescente , Adulto , Artroplastia de Reemplazo de Cadera/métodos , Estudios de Cohortes , Falla de Equipo , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Estimación de Kaplan-Meier , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Osteoartritis de la Cadera/diagnóstico por imagen , Osteólisis/epidemiología , Radiografía , Reoperación , Resultado del Tratamiento , Adulto Joven
13.
Knee ; 13(5): 395-6, 2006 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-16837199

RESUMEN

Melorheostosis is a rare condition which can cause soft tissue joint contractures. We present a case of melorheostosis causing disabling knee joint contracture, treated successfully by total knee arthroplasty.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Contractura/cirugía , Articulación de la Rodilla/cirugía , Melorreostosis/cirugía , Adulto , Contractura/fisiopatología , Femenino , Humanos , Articulación de la Rodilla/fisiopatología , Melorreostosis/fisiopatología
14.
J Coll Physicians Surg Pak ; 25(7): 531-3, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26208560

RESUMEN

This article outlines some of the key concepts in leadership (both styles and theories) to provide a platform for further learning and to help the modern day orthopaedic surgeons to apply these concepts to their current practice. It is focused on two major aspects: management of medical organizations and effective twenty-first century care by surgeons through proper leadership guide and aimed in improving patient care outcomes. Practicing proper leadership skills based on evidence resulted in effective management of organization. Thus achieving patient's satisfaction.


Asunto(s)
Atención a la Salud/organización & administración , Liderazgo , Ortopedia , Cirujanos , Humanos , Relaciones Interprofesionales , Competencia Profesional , Reino Unido
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA