Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 156
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
J Immunol ; 212(12): 1922-1931, 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38683124

RESUMEN

Although high titers of neutralizing Abs in human serum are associated with protection from reinfection by SARS-CoV-2, there is considerable heterogeneity in human serum-neutralizing Abs against SARS-CoV-2 during convalescence between individuals. Standard human serum live virus neutralization assays require inactivation of serum/plasma prior to testing. In this study, we report that the SARS-CoV-2 neutralization titers of human convalescent sera were relatively consistent across all disease states except for severe COVID-19, which yielded significantly higher neutralization titers. Furthermore, we show that heat inactivation of human serum significantly lowered neutralization activity in a live virus SARS-CoV-2 neutralization assay. Heat inactivation of human convalescent serum was shown to inactivate complement proteins, and the contribution of complement in SARS-CoV-2 neutralization was often >50% of the neutralizing activity of human sera without heat inactivation and could account for neutralizing activity when standard titers were zero after heat inactivation. This effect was also observed in COVID-19 vaccinees and could be abolished in individuals who were undergoing treatment with therapeutic anti-complement Abs. Complement activity was mainly dependent on the classical pathway with little contributions from mannose-binding lectin and alternative pathways. Our study demonstrates the importance of the complement pathway in significantly increasing viral neutralization activity against SARS-CoV-2 in spike seropositive individuals.


Asunto(s)
Anticuerpos Neutralizantes , Anticuerpos Antivirales , Vacunas contra la COVID-19 , COVID-19 , Vía Clásica del Complemento , Pruebas de Neutralización , SARS-CoV-2 , Humanos , SARS-CoV-2/inmunología , Anticuerpos Neutralizantes/inmunología , Anticuerpos Neutralizantes/sangre , COVID-19/inmunología , Anticuerpos Antivirales/inmunología , Anticuerpos Antivirales/sangre , Vía Clásica del Complemento/inmunología , Vacunas contra la COVID-19/inmunología , Masculino , Femenino , Persona de Mediana Edad , Adulto , Convalecencia , Anciano , Proteínas del Sistema Complemento/inmunología
2.
PLoS Pathog ; 18(8): e1010724, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35998203

RESUMEN

A dysregulated proinflammatory cytokine response is characteristic of severe coronavirus infections caused by SARS-CoV-2, yet our understanding of the underlying mechanism responsible for this imbalanced immune response remains incomplete. Processing bodies (PBs) are cytoplasmic membraneless ribonucleoprotein granules that control innate immune responses by mediating the constitutive decay or suppression of mRNA transcripts, including many that encode proinflammatory cytokines. PB formation promotes turnover or suppression of cytokine RNAs, whereas PB disassembly corresponds with the increased stability and/or translation of these cytokine RNAs. Many viruses cause PB disassembly, an event that can be viewed as a switch that rapidly relieves cytokine RNA repression and permits the infected cell to respond to viral infection. Prior to this submission, no information was known about how human coronaviruses (CoVs) impacted PBs. Here, we show SARS-CoV-2 and the common cold CoVs, OC43 and 229E, induced PB loss. We screened a SARS-CoV-2 gene library and identified that expression of the viral nucleocapsid (N) protein from SARS-CoV-2 was sufficient to mediate PB disassembly. RNA fluorescent in situ hybridization revealed that transcripts encoding TNF and IL-6 localized to PBs in control cells. PB loss correlated with the increased cytoplasmic localization of these transcripts in SARS-CoV-2 N protein-expressing cells. Ectopic expression of the N proteins from five other human coronaviruses (OC43, MERS, 229E, NL63 and SARS-CoV) did not cause significant PB disassembly, suggesting that this feature is unique to SARS-CoV-2 N protein. These data suggest that SARS-CoV-2-mediated PB disassembly contributes to the dysregulation of proinflammatory cytokine production observed during severe SARS-CoV-2 infection.


Asunto(s)
COVID-19 , Coronavirus Humano OC43 , Citocinas , Humanos , Hibridación Fluorescente in Situ , Cuerpos de Procesamiento , ARN , SARS-CoV-2
3.
Br J Clin Pharmacol ; 2024 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-38817198

RESUMEN

AIM: Understanding how COVID-19 impacts the expression of clinically relevant drug metabolizing enzymes and membrane transporters (DMETs) is vital for addressing potential safety and efficacy concerns related to systemic and peripheral drug concentrations. This study investigates the impact of COVID-19 severity on DMETs expression and the underlying mechanisms to inform the design of precise clinical dosing regimens for affected patients. METHODS: Transcriptomics analysis of 102 DMETs, 10 inflammatory markers, and 12 xenosensing regulatory genes was conducted on nasopharyngeal swabs from 50 SARS-CoV-2 positive (17 outpatients, 16 non-ICU, and 17 ICU) and 13 SARS-CoV-2 negative individuals, clinically tested through qPCR, in the Greater Toronto area from October 2020 to October 2021. RESULTS: We observed a significant differential gene expression for 42 DMETs, 6 inflammatory markers, and 9 xenosensing regulatory genes. COVID-19 severity was associated with the upregulation of AKR1C1, MGST1, and SULT1E1, and downregulation of ABCC10, CYP3A43, and SLC29A4 expressions. Altogether, SARS-CoV-2-positive patients showed an upregulation in CYP2C9, CYP2C19, AKR1C1, SULT1B1, SULT2B1, and SLCO4A1 and downregulation in FMO5, MGST3, ABCC5, and SLCO4C1 compared with SARS-CoV-2 negative individuals. These dysregulations were associated with significant changes in the expression of inflammatory and xenosensing regulatory genes driven by the disease. GSTM3, PPARA, and AKR1C1 are potential biomarkers of the observed DMETs dysregulation pattern in nasopharyngeal swabs of outpatients, non-ICU, and ICU patients, respectively. CONCLUSION: The severity of COVID-19 is associated with the dysregulation of DMETs involved in processing commonly prescribed drugs, suggesting potential disease-drug interactions, especially for narrow therapeutic index drugs.

4.
J Immunol ; 208(2): 429-443, 2022 01 15.
Artículo en Inglés | MEDLINE | ID: mdl-34903642

RESUMEN

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) induces T cell, B cell, and Ab responses that are detected for several months in recovered individuals. Whether this response resembles a typical respiratory viral infection is a matter of debate. In this study, we followed T cell and Ab responses in 24 mainly nonhospitalized human subjects who had recovered from PCR-confirmed SARS-CoV-2 infection at two time points (median of 45 and 145 d after symptom onset). Ab responses were detected in 95% of subjects, with a strong correlation between plasma and salivary anti-spike (anti-S) and anti-receptor binding domain IgG, as well as a correlation between circulating T follicular helper cells and the SARS-CoV-2-specific IgG response. T cell responses to SARS-CoV-2 peptides were determined using intracellular cytokine staining, activation markers, proliferation, and cytokine secretion. All study subjects had a T cell response to at least one SARS-CoV-2 Ag based on at least one T cell assay. CD4+ responses were largely of the Th1 phenotype, but with a lower ratio of IFN-γ- to IL-2-producing cells and a lower frequency of CD8+:CD4+ T cells than in influenza A virus (IAV)-specific memory responses within the same subjects. Analysis of secreted molecules also revealed a lower ratio of IFN-γ to IL-2 and an altered cytotoxic profile for SARS-CoV-2 S- and nucleocapsid-specific responses compared with IAV-specific responses. These data suggest that the memory T cell phenotype after a single infection with SARS-CoV-2 persists over time, with an altered cytokine and cytotoxicity profile compared with long-term memory to whole IAV within the same subjects.


Asunto(s)
Formación de Anticuerpos , COVID-19/inmunología , Inmunidad Celular , Inmunoglobulina G/inmunología , SARS-CoV-2/inmunología , Glicoproteína de la Espiga del Coronavirus/inmunología , Células TH1/inmunología , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Factores de Tiempo
5.
J Infect Dis ; 2023 Nov 29.
Artículo en Inglés | MEDLINE | ID: mdl-38029414

RESUMEN

BACKGROUND: Randomized trials conducted in low- and middle-income settings demonstrated efficacy of influenza vaccination during pregnancy against influenza infection among infants <6 months of age. However, vaccine effectiveness (VE) estimates from settings with different population characteristics and influenza seasonality remain limited. METHODS: We conducted a test-negative study in Ontario, Canada. All influenza virus tests among infants <6 months from 2010-2019 were identified and linked with health databases to ascertain information on maternal-infant dyads. VE was estimated from the odds ratio for influenza vaccination during pregnancy among cases versus controls, computed using logistic regression with adjustment for potential confounders. RESULTS: Among 23,806 infants tested for influenza, 1,783 (7.5%) were positive and 1,708 (7.2%) were born to mothers vaccinated against influenza during pregnancy. VE against laboratory-confirmed infant influenza infection was 64% (95% confidence interval [CI]: 50%-74%). VE was similar by trimester of vaccination (1st/2nd: 66%, 40%-80%; 3rd: 63%, 46%-74%), infant age at testing (0-<2 months: 63%, 46%-75%; 2-<6 months: 64%, 36%-79%), and gestational age at birth (≥37 weeks: 64%, 50%-75%; < 37 weeks: 61%, 4%-86%). VE against influenza hospitalization was 67% (95%CI: 50%-78%). CONCLUSIONS: Influenza vaccination during pregnancy offers effective protection to infants <6 months, for whom vaccines are not currently available.

6.
Clin Infect Dis ; 77(2): 303-311, 2023 07 26.
Artículo en Inglés | MEDLINE | ID: mdl-36942534

RESUMEN

BACKGROUND: Older adults are recommended to receive influenza vaccination annually, and many use statins. Statins have immunomodulatory properties that might modify influenza vaccine effectiveness (VE) and alter influenza infection risk. METHODS: Using the test-negative design and linked laboratory and health administrative databases in Ontario, Canada, we estimated VE against laboratory-confirmed influenza among community-dwelling statin users and nonusers aged ≥66 years during the 2010-2011 to 2018-2019 influenza seasons. We also estimated the odds ratio for influenza infection comparing statin users and nonusers by vaccination status. RESULTS: Among persons tested for influenza across the 9 seasons, 54 243 had continuous statin exposure before testing and 48 469 were deemed unexposed. The VE against laboratory-confirmed influenza was similar between statin users and nonusers (17% [95% confidence interval, 13%-20%] and 17% [13%-21%] respectively; test for interaction, P = .87). In both vaccinated and unvaccinated persons, statin users had higher odds of laboratory-confirmed influenza than nonusers (odds ratios for vaccinated and unvaccinated persons 1.15 [95% confidence interval, 1.10-1.21] and 1.15 [1.10-1.20], respectively). These findings were consistent by mean daily dose and statin type. VE did not differ between users and nonusers of other cardiovascular drugs, except for ß-blockers. We did not observe that vaccinated and unvaccinated users of these drugs had increased odds of influenza, except for unvaccinated ß-blocker users. CONCLUSIONS: Influenza VE did not differ between statin users and nonusers. Statin use was associated with increased odds of laboratory-confirmed influenza in vaccinated and unvaccinated persons, but these associations might be affected by residual confounding.


Asunto(s)
Inhibidores de Hidroximetilglutaril-CoA Reductasas , Vacunas contra la Influenza , Gripe Humana , Humanos , Anciano , Gripe Humana/epidemiología , Gripe Humana/prevención & control , Inhibidores de Hidroximetilglutaril-CoA Reductasas/uso terapéutico , Eficacia de las Vacunas , Vacunación , Ontario/epidemiología , Estaciones del Año
7.
Emerg Infect Dis ; 29(7): 1386-1396, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37308158

RESUMEN

Isolating and characterizing emerging SARS-CoV-2 variants is key to understanding virus pathogenesis. In this study, we isolated samples of the SARS-CoV-2 R.1 lineage, categorized as a variant under monitoring by the World Health Organization, and evaluated their sensitivity to neutralizing antibodies and type I interferons. We used convalescent serum samples from persons in Canada infected either with ancestral virus (wave 1) or the B.1.1.7 (Alpha) variant of concern (wave 3) for testing neutralization sensitivity. The R.1 isolates were potently neutralized by both the wave 1 and wave 3 convalescent serum samples, unlike the B.1.351 (Beta) variant of concern. Of note, the R.1 variant was significantly more resistant to type I interferons (IFN-α/ß) than was the ancestral isolate. Our study demonstrates that the R.1 variant retained sensitivity to neutralizing antibodies but evolved resistance to type I interferons. This critical driving force will influence the trajectory of the pandemic.


Asunto(s)
COVID-19 , Interferón Tipo I , Humanos , SARS-CoV-2/genética , Interferón Tipo I/genética , Anticuerpos Neutralizantes , Sueroterapia para COVID-19 , Canadá/epidemiología , Anticuerpos Antivirales , Glicoproteína de la Espiga del Coronavirus
8.
Anal Chem ; 95(14): 5877-5885, 2023 04 11.
Artículo en Inglés | MEDLINE | ID: mdl-37000033

RESUMEN

Designing diagnostic assays to genotype rapidly mutating viruses remains a challenge despite the overall improvements in nucleic acid detection technologies. RT-PCR and next-generation sequencing are unsuitable for genotyping during outbreaks or in point-of-care detection due to their infrastructure requirements and longer turnaround times. We developed a quantum dot barcode multiplexing system to genotype mutated viruses. We designed multiple quantum dot barcodes to target conserved, wildtype, and mutated regions of SARS-CoV-2. We calculated ratios of the signal output from different barcodes that enabled SARS-CoV-2 detection and identified SARS-CoV-2 variant strains from a sample. We detected different sequence types, including conserved genes, nucleotide deletions, and single nucleotide substitutions. Our system detected SARS-CoV-2 patient specimens with 98% sensitivity and 94% specificity across 91 patient samples. Further, we leveraged our barcoding and ratio system to track the emergence of the N501Y SARS-CoV-2 mutation from December 2020 to May 2021 and demonstrated that the more transmissible N501Y mutation started to dominate infections by April 2021. Our barcoding and signal ratio approach can genotype viruses and track the emergence of viral mutations in a single diagnostic test. This technology can be extended to tracking other viruses. Combined with smartphone detection technologies, this assay can be adapted for point-of-care tracking of viral mutations in real time.


Asunto(s)
COVID-19 , Ácidos Nucleicos , Humanos , SARS-CoV-2/genética , COVID-19/diagnóstico , Genotipo , Nucleótidos , Mutación
9.
J Virol ; 96(13): e0050922, 2022 07 13.
Artículo en Inglés | MEDLINE | ID: mdl-35699447

RESUMEN

Cell-mediated immunity is critical for long-term protection against most viral infections, including coronaviruses. We studied 23 severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2)-infected survivors over a 1-year post-symptom onset (PSO) interval by ex vivo cytokine enzyme-linked immunosorbent spot assay (ELISpot) assay. All subjects demonstrated SARS-CoV-2-specific gamma interferon (IFN-γ), interleukin 2 (IL-2), and granzyme B (GzmB) T cell responses at presentation, with greater frequencies in severe disease. Cytokines, mainly produced by CD4+ T cells, targeted all structural proteins (nucleocapsid, membrane, and spike) except envelope, with GzmB and IL-2 greater than IFN-γ. Mathematical modeling predicted that (i) cytokine responses peaked at 6 days for IFN-γ, 36 days for IL-2, and 7 days for GzmB, (ii) severe illness was associated with reduced IFN-γ and GzmB but increased IL-2 production rates, and (iii) males displayed greater production of IFN-γ, whereas females produced more GzmB. Ex vivo responses declined over time, with persistence of IL-2 in 86% and of IFN-γ and GzmB in 70% of subjects at a median of 336 days PSO. The average half-life of SARS-CoV-2-specific cytokine-producing cells was modeled to be 139 days (~4.6 months). Potent T cell proliferative responses persisted throughout observation, were CD4 dominant, and were capable of producing all 3 cytokines. Several immunodominant CD4 and CD8 epitopes identified in this study were shared by seasonal coronaviruses or SARS-CoV-1 in the nucleocapsid and membrane regions. Both SARS-CoV-2-specific CD4+ and CD8+ T cell clones were able to kill target cells, though CD8 tended to be more potent. IMPORTANCE Our findings highlight the relative importance of SARS-CoV-2-specific GzmB-producing T cell responses in SARS-CoV-2 control and shared CD4 and CD8 immunodominant epitopes in seasonal coronaviruses or SARS-CoV-1, and they indicate robust persistence of T cell memory at least 1 year after infection. Our findings should inform future strategies to induce T cell vaccines against SARS-CoV-2 and other coronaviruses.


Asunto(s)
COVID-19 , Citocinas , Inmunidad , SARS-CoV-2 , Linfocitos T CD4-Positivos , Linfocitos T CD8-positivos , COVID-19/inmunología , Vacunas contra la COVID-19 , Citocinas/inmunología , Femenino , Humanos , Memoria Inmunológica , Interferón gamma/metabolismo , Interleucina-2/inmunología , Masculino , Índice de Severidad de la Enfermedad , Factores de Tiempo
10.
Biol Lett ; 19(11): 20230358, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37964576

RESUMEN

Africa experiences frequent emerging disease outbreaks among humans, with bats often proposed as zoonotic pathogen hosts. We comprehensively reviewed virus-bat findings from papers published between 1978 and 2020 to evaluate the evidence that African bats are reservoir and/or bridging hosts for viruses that cause human disease. We present data from 162 papers (of 1322) with original findings on (1) numbers and species of bats sampled across bat families and the continent, (2) how bats were selected for study inclusion, (3) if bats were terminally sampled, (4) what types of ecological data, if any, were recorded and (5) which viruses were detected and with what methodology. We propose a scheme for evaluating presumed virus-host relationships by evidence type and quality, using the contrasting available evidence for Orthoebolavirus versus Orthomarburgvirus as an example. We review the wording in abstracts and discussions of all 162 papers, identifying key framing terms, how these refer to findings, and how they might contribute to people's beliefs about bats. We discuss the impact of scientific research communication on public perception and emphasize the need for strategies that minimize human-bat conflict and support bat conservation. Finally, we make recommendations for best practices that will improve virological study metadata.


Asunto(s)
Quirópteros , Virus , Animales , Humanos , Reservorios de Enfermedades , África
11.
J Immunol ; 206(1): 37-50, 2021 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-33208459

RESUMEN

There is a pressing need for an in-depth understanding of immunity to SARS-CoV-2. In this study, we investigated human T cell recall responses to fully glycosylated spike trimer, recombinant N protein, as well as to S, N, M, and E peptide pools in the early convalescent phase and compared them with influenza-specific memory responses from the same donors. All subjects showed SARS-CoV-2-specific T cell responses to at least one Ag. Both SARS-CoV-2-specific and influenza-specific CD4+ T cell responses were predominantly of the central memory phenotype; however SARS-CoV-2-specific CD4+ T cells exhibited a lower IFN-γ to TNF ratio compared with influenza-specific memory responses from the same donors, independent of disease severity. SARS-CoV-2-specific T cells were less multifunctional than influenza-specific T cells, particularly in severe cases, potentially suggesting exhaustion. Most SARS-CoV-2-convalescent subjects also produced IFN-γ in response to seasonal OC43 S protein. We observed granzyme B+/IFN-γ+, CD4+, and CD8+ proliferative responses to peptide pools in most individuals, with CD4+ T cell responses predominating over CD8+ T cell responses. Peripheral T follicular helper (pTfh) responses to S or N strongly correlated with serum neutralization assays as well as receptor binding domain-specific IgA; however, the frequency of pTfh responses to SARS-CoV-2 was lower than the frequency of pTfh responses to influenza virus. Overall, T cell responses to SARS-CoV-2 are robust; however, CD4+ Th1 responses predominate over CD8+ T cell responses, have a more inflammatory profile, and have a weaker pTfh response than the response to influenza virus within the same donors, potentially contributing to COVID-19 disease.


Asunto(s)
Antígenos Virales/inmunología , Linfocitos T CD4-Positivos/inmunología , Inflamación/inmunología , Orthomyxoviridae/inmunología , SARS-CoV-2/inmunología , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad
12.
J Infect Dis ; 225(5): 768-776, 2022 03 02.
Artículo en Inglés | MEDLINE | ID: mdl-34850051

RESUMEN

BACKGROUND: We determined the burden of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in air and on surfaces in rooms of patients hospitalized with coronavirus disease 2019 (COVID-19) and investigated patient characteristics associated with SARS-CoV-2 environmental contamination. METHODS: Nasopharyngeal swabs, surface, and air samples were collected from the rooms of 78 inpatients with COVID-19 at 6 acute care hospitals in Toronto from March to May 2020. Samples were tested for SARS-CoV-2 ribonucleic acid (RNA), cultured to determine potential infectivity, and whole viral genomes were sequenced. Association between patient factors and detection of SARS-CoV-2 RNA in surface samples were investigated. RESULTS: Severe acute respiratory syndrome coronavirus 2 RNA was detected from surfaces (125 of 474 samples; 42 of 78 patients) and air (3 of 146 samples; 3 of 45 patients); 17% (6 of 36) of surface samples from 3 patients yielded viable virus. Viral sequences from nasopharyngeal and surface samples clustered by patient. Multivariable analysis indicated hypoxia at admission, polymerase chain reaction-positive nasopharyngeal swab (cycle threshold of ≤30) on or after surface sampling date, higher Charlson comorbidity score, and shorter time from onset of illness to sampling date were significantly associated with detection of SARS-CoV-2 RNA in surface samples. CONCLUSIONS: The infrequent recovery of infectious SARS-CoV-2 virus from the environment suggests that the risk to healthcare workers from air and near-patient surfaces in acute care hospital wards is likely limited.


Asunto(s)
COVID-19 , Nasofaringe/virología , Aerosoles y Gotitas Respiratorias , SARS-CoV-2/aislamiento & purificación , Adulto , Anciano , Microbiología del Aire , COVID-19/epidemiología , COVID-19/prevención & control , COVID-19/transmisión , Prueba de Ácido Nucleico para COVID-19 , Canadá/epidemiología , Exposición a Riesgos Ambientales , Personal de Salud , Humanos , Pacientes Internos , Persona de Mediana Edad , Pandemias/prevención & control , SARS-CoV-2/genética
13.
J Am Chem Soc ; 144(40): 18338-18349, 2022 10 12.
Artículo en Inglés | MEDLINE | ID: mdl-36173381

RESUMEN

The development of robust biosensing strategies that can be easily implemented in everyday life remains a challenge for the future of modern biosensor research. While several reagentless approaches have attempted to address this challenge, they often achieve user-friendliness through sacrificing sensitivity or universality. While acceptable for certain applications, these trade-offs hinder the widespread adoption of reagentless biosensing technologies. Here, we report a novel approach to reagentless biosensing that achieves high sensitivity, rapid detection, and universality using the SARS-CoV-2 virus as a model target. Universality is achieved by using nanoscale molecular pendulums, which enables reagentless electrochemical biosensing through a variable antibody recognition element. Enhanced sensitivity and rapid detection are accomplished by incorporating the coffee-ring phenomenon into the sensing scheme, allowing for target preconcentration on a ring-shaped electrode. Using this approach, we obtained limits of detection of 1 fg/mL and 20 copies/mL for the SARS-CoV-2 nucleoproteins and viral particles, respectively. In addition, clinical sample analysis showed excellent agreement with Ct values from PCR-positive SARS-CoV-2 patients.


Asunto(s)
Técnicas Biosensibles , COVID-19 , COVID-19/diagnóstico , Electrodos , Humanos , Nucleoproteínas , SARS-CoV-2/genética
14.
Am J Respir Crit Care Med ; 203(9): 1112-1118, 2021 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-33534659

RESUMEN

Rationale: Patients with severe coronavirus disease (COVID-19) require supplemental oxygen and ventilatory support. It is unclear whether some respiratory support devices may increase the dispersion of infectious bioaerosols and thereby place healthcare workers at increased risk of infection with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2).Objectives: To quantitatively compare viral dispersion from invasive and noninvasive respiratory support modalities.Methods: This study used a simulated ICU room with a breathing-patient simulator exhaling nebulized bacteriophages from the lower respiratory tract with various respiratory support modalities: invasive ventilation (through an endotracheal tube with an inflated cuff connected to a mechanical ventilator), helmet ventilation with a positive end-expiratory pressure (PEEP) valve, noninvasive bilevel positive-pressure ventilation, nonrebreather face masks, high-flow nasal oxygen (HFNO), and nasal prongs.Measurements and Main Results: Invasive ventilation and helmet ventilation with a PEEP valve were associated with the lowest bacteriophage concentrations in the air, and HFNO and nasal prongs were associated with the highest concentrations. At the intubating position, bacteriophage concentrations associated with HFNO (2.66 × 104 plaque-forming units [PFU]/L of air sampled), nasal prongs (1.60 × 104 PFU/L of air sampled), nonrebreather face masks (7.87 × 102 PFU/L of air sampled), and bilevel positive airway pressure (1.91 × 102 PFU/L of air sampled) were significantly higher than those associated with invasive ventilation (P < 0.05 for each). The difference between bacteriophage concentrations associated with helmet ventilation with a PEEP valve (4.29 × 10-1 PFU/L of air sampled) and bacteriophage concentrations associated with invasive ventilation was not statistically significant.Conclusions: These findings highlight the potential differential risk of dispersing virus among respiratory support devices and the importance of appropriate infection prevention and control practices and personal protective equipment for healthcare workers when caring for patients with transmissible respiratory viral infections such as SARS-CoV-2.


Asunto(s)
Cuidados Críticos/métodos , ADN Viral/análisis , Transmisión de Enfermedad Infecciosa/prevención & control , Insuficiencia Respiratoria/terapia , Ventiladores Mecánicos/efectos adversos , Virosis/virología , Virus/genética , Humanos , Virosis/prevención & control , Virosis/transmisión
15.
Nano Lett ; 21(12): 5209-5216, 2021 06 23.
Artículo en Inglés | MEDLINE | ID: mdl-34110166

RESUMEN

The ability to rapidly diagnose, track, and disseminate information for SARS-CoV-2 is critical to minimize its spread. Here, we engineered a portable smartphone-based quantum barcode serological assay device for real-time surveillance of patients infected with SARS-CoV-2. Our device achieved a clinical sensitivity of 90% and specificity of 100% for SARS-CoV-2, as compared to 34% and 100%, respectively, for lateral flow assays in a head-to-head comparison. The lateral flow assay misdiagnosed ∼2 out of 3 SARS-CoV-2 positive patients. Our quantum dot barcode device has ∼3 times greater clinical sensitivity because it is ∼140 times more analytically sensitive than lateral flow assays. Our device can diagnose SARS-CoV-2 at different sampling dates and infectious severity. We developed a databasing app to provide instantaneous results to inform patients, physicians, and public health agencies. This assay and device enable real-time surveillance of SARS-CoV-2 seroprevalence and potential immunity.


Asunto(s)
COVID-19 , Puntos Cuánticos , Humanos , Inmunoensayo , SARS-CoV-2 , Sensibilidad y Especificidad , Estudios Seroepidemiológicos , Teléfono Inteligente
16.
Air Med J ; 41(1): 109-113, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35248328

RESUMEN

OBJECTIVE: It is unclear whether supplemental oxygen and noninvasive ventilation respiratory support devices increase the dispersion of potentially infectious bioaerosols in a pressurized air medical cabin. This study quantitatively compared particle dispersion from respiratory support modalities in an air medical cabin during flight. METHODS: Dispersion was measured in a fixed wing air ambulance during flight with a breathing medical mannequin simulator exhaling nebulized saline from the lower respiratory tract with the following respiratory support modalities: a nasal cannula with a surgical mask, high-flow nasal oxygen (HFNO) with a surgical mask, and noninvasive bilevel positive airway pressure (BiPAP) ventilation. RESULTS: Nasal cannula oxygen with a surgical mask was associated with the highest particle concentrations. In the absence of mask seal leaks, BiPAP was associated with 1 order of magnitude lower particle concentration compared with a nasal cannula with a surgical mask. Particle concentrations associated with HFNO with a surgical mask were lower than a nasal cannula with a surgical mask but higher than BiPAP. CONCLUSIONS: Particle dispersion associated with the use of BiPAP and HFNO with a surgical mask is lower than nasal cannula oxygen with a surgical mask. These findings may assist air medical organizations with operational decisions where little data exist about respiratory particle dispersion.


Asunto(s)
Servicios Médicos de Urgencia , Ventilación no Invasiva , Aeronaves , Humanos , Oxígeno , Terapia por Inhalación de Oxígeno , Sistema Respiratorio
17.
Clin Infect Dis ; 73(5): e1191-e1199, 2021 09 07.
Artículo en Inglés | MEDLINE | ID: mdl-33354709

RESUMEN

BACKGROUND: Older adults are at increased risk of mortality from influenza infections. We estimated influenza vaccine effectiveness (VE) against mortality following laboratory-confirmed influenza. METHODS: Using a test-negative design study and linked laboratory and health administrative databases in Ontario, Canada, we estimated VE against all-cause mortality following laboratory-confirmed influenza for community-dwelling adults aged >65 years during the 2010-2011 to 2015-2016 influenza seasons. RESULTS: Among 54 116 older adults tested for influenza across the 6 seasons, 6837 died within 30 days of specimen collection. Thirteen percent (925 individuals) tested positive for influenza, and 50.6% were considered vaccinated for that season. Only 23.2% of influenza test-positive cases had influenza recorded as their underlying cause of death. Before and after multivariable adjustment, we estimated VE against all-cause mortality following laboratory-confirmed influenza to be 20% (95% confidence interval [CI], 8%-30%) and 20% (95% CI, 7%-30%), respectively. This estimate increased to 34% after correcting for influenza vaccination exposure misclassification. We observed significant VE against deaths following influenza confirmation during 2014-2015 (VE = 26% [95% CI, 5%-42%]). We also observed significant VE against deaths following confirmation of influenza A/H1N1 and A/H3N2, and against deaths with COPD as the underlying cause. CONCLUSIONS: These results support the importance of influenza vaccination in older adults, who account for most influenza-associated deaths annually.


Asunto(s)
Subtipo H1N1 del Virus de la Influenza A , Vacunas contra la Influenza , Gripe Humana , Anciano , Estudios de Casos y Controles , Humanos , Subtipo H3N2 del Virus de la Influenza A , Virus de la Influenza B , Gripe Humana/epidemiología , Gripe Humana/prevención & control , Laboratorios , Ontario/epidemiología , Estaciones del Año , Vacunación
18.
Clin Infect Dis ; 72(6): 1064-1066, 2021 03 15.
Artículo en Inglés | MEDLINE | ID: mdl-32584972

RESUMEN

We enrolled 91 consecutive inpatients with COVID-19 at 6 hospitals in Toronto, Canada, and tested 1 nasopharyngeal swab/saliva sample pair from each patient using real-time RT-PCR for severe acute respiratory syndrome coronavirus 2. Sensitivity was 89% for nasopharyngeal swabs and 72% for saliva (P = .02). Difference in sensitivity was greatest for sample pairs collected later in illness.


Asunto(s)
COVID-19 , SARS-CoV-2 , Canadá , Humanos , Nasofaringe , Reacción en Cadena en Tiempo Real de la Polimerasa , Saliva
19.
J Am Chem Soc ; 143(4): 1722-1727, 2021 02 03.
Artículo en Inglés | MEDLINE | ID: mdl-33481575

RESUMEN

The development of new methods for direct viral detection using streamlined and ideally reagent-free assays is a timely and important, but challenging, problem. The challenge of combatting the COVID-19 pandemic has been exacerbated by the lack of rapid and effective methods to identify viral pathogens like SARS-CoV-2 on-demand. Existing gold standard nucleic acid-based approaches require enzymatic amplification to achieve clinically relevant levels of sensitivity and are not typically used outside of a laboratory setting. Here, we report reagent-free viral sensing that directly reads out the presence of viral particles in 5 minutes using only a sensor-modified electrode chip. The approach relies on a class of electrode-tethered sensors bearing an analyte-binding antibody displayed on a negatively charged DNA linker that also features a tethered redox probe. When a positive potential is applied, the sensor is transported to the electrode surface. Using chronoamperometry, the presence of viral particles and proteins can be detected as these species increase the hydrodynamic drag on the sensor. This report is the first virus-detecting assay that uses the kinetic response of a probe/virus complex to analyze the complexation state of the antibody. We demonstrate the performance of this sensing approach as a means to detect, within 5 min, the presence of the SARS-CoV-2 virus and its associated spike protein in test samples and in unprocessed patient saliva.


Asunto(s)
Técnicas Biosensibles/métodos , Prueba de COVID-19/métodos , COVID-19/virología , Técnicas Electroquímicas/métodos , SARS-CoV-2/aislamiento & purificación , Virión/aislamiento & purificación , Técnicas Biosensibles/instrumentación , Prueba de COVID-19/instrumentación , Técnicas Electroquímicas/instrumentación , Electrodos , Humanos , Pruebas en el Punto de Atención , Saliva/virología
20.
CMAJ ; 193(13): E439-E446, 2021 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-33782171

RESUMEN

BACKGROUND: Data on the outcomes of noninfluenza respiratory virus (NIRV) infections among hospitalized adults are lacking. We aimed to study the burden, severity and outcomes of NIRV infections in this population. METHODS: We analyzed pooled patient data from 2 hospital-based respiratory virus surveillance cohorts in 2 regions of Canada during 3 consecutive seasons (2015/16, 2016/17, 2017/18; n = 2119). We included patients aged ≥ 18 years who developed influenza-like illness or pneumonia and were hospitalized for management. We included patients confirmed positive for ≥ 1 virus by multiplex polymerase chain reaction assays (respiratory syncytial virus [RSV], human rhinovirus/enterovirus (hRV), human coronavirus (hCoV), metapneumovirus, parainfluenza virus, adenovirus, influenza viruses). We compared patient characteristics, clinical severity conventional outcomes (e.g., hospital length-of stay, 30-day mortality) and ordinal outcomes (5 levels: discharged, receiving convalescent care, acute ward or intensive care unit [ICU] care and death) for patients with NIRV infections and those with influenza. RESULTS: Among 2119 adults who were admitted to hospital, 1156 patients (54.6%) had NIRV infections (hRV 14.9%, RSV 12.9%, hCoV 8.2%) and 963 patients (45.4%) had influenza (n = 963). Patients with NIRVs were younger (mean 66.4 [standard deviation 20.4] yr), and more commonly had immunocompromising conditions (30.3%) and delay in diagnosis (median 4.0 [interquartile range (IQR) 2.0-7.0] days). Overall, 14.6% (12.4%-19.5%) of NIRV infections were acquired in hospital. Admission to ICU (18.2%, median 6.0 [IQR 3.0-13.0] d), hospital length-of-stay (median 5.0 [IQR 2.0-10.0] d) and 30-day mortality (8.4%; RSV 9.5%, hRV 6.6%, hCoV 9.2%) and the ordinal outcomes were similar for patients with NIRV infection and those with influenza. Age > 60 years, immunocompromised state and hospital-acquired viral infection were associated with worse outcomes. The estimated median cost per acute care admission was $6000 (IQR $2000-$16 000). INTERPRETATION: The burden of NIRV infection is substantial in adults admitted to hospital and associated outcomes may be as severe as for influenza, suggesting a need to prioritize therapeutics and vaccines for at-risk people.


Asunto(s)
Costo de Enfermedad , Hospitalización , Infecciones del Sistema Respiratorio/epidemiología , Virosis/epidemiología , Adulto , Anciano , Anciano de 80 o más Años , Canadá , Estudios de Cohortes , Monitoreo Epidemiológico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infecciones del Sistema Respiratorio/virología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA