Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Endovasc Ther ; : 15266028241253133, 2024 May 26.
Artículo en Inglés | MEDLINE | ID: mdl-38798060

RESUMEN

CLINICAL IMPACT: Based on our study, no antithrombotic therapy is significantly associated with bridging stent occlusion, and no evidence of the superiority of other antithrombotic therapy exists. Nevertehless, due to the low number of bridging stent occlusions, this study can neither support nor reject the PRINCE2SS recommendations. Further studies with larger cohorts are needed to determine clear guideliness of the best antithrombotic treatment regimen after complex enfovascular aortic repair.

2.
Ann Vasc Surg ; 108: 179-186, 2024 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38950853

RESUMEN

OBJECTIVE: To investigate the role of the Omniflow II prosthesis in the prevention of vascular graft infection (VGI) in patients with peripheral arterial disease and to report on short-and mid-term graft-related morbidity. MATERIAL AND METHODS: Patients were included in prospective registry between October 2019 and March 2023. The primary endpoint was to report infection-related problems, operation-related wound problems, and short- and mid-term graft-related morbidity. Secondary endpoint was to report the bypass patency rates and limb salvage rates. RESULTS: A total of 146 Omniflow II grafts were implanted in 125 patients. Sixty-seven patients (45.9%) received a femoral interposition graft, and 77 patients (52.7%) underwent ipsilateral bypass surgery (femoropopliteal or femorocrural). Forty-one patients (28.1%) underwent crural bypass surgery. Seventy-six patients (52.1%) had previous vascular operation in the groin. The mean follow-up time was 352 days (range 0-1108 days). 3.4% of the patients suffered a wound infection limited to the dermis, and in 8.2%, the subcutaneous tissue was involved. Five early VGI (3.4%) and one late VGI (0.7%) occurred. One year primary patency rate of above-the-knee bypass was significantly better compared to the bypass below the knee (74.5% ± 0.131 versus 54% ± 0.126 (P = 0.049)). This difference was not significantly different when below-the-knee bypass surgery was compared with crural bypass surgery (54% ± 0.126 versus 23.8% ± 0.080 (P = 0.098)). CONCLUSIONS: The performance of the Omniflow II prosthesis in the preventive setting is highly influenced by the anatomic location of the distal anastomosis. No influence on the incidence of postoperative wound problems could be observed. The rate of Omniflow II VGI in a high-risk population is similar to reported outcomes in other prosthetic grafts.


Asunto(s)
Implantación de Prótesis Vascular , Prótesis Vascular , Recuperación del Miembro , Extremidad Inferior , Enfermedad Arterial Periférica , Infecciones Relacionadas con Prótesis , Sistema de Registros , Infección de la Herida Quirúrgica , Grado de Desobstrucción Vascular , Humanos , Masculino , Femenino , Anciano , Estudios Prospectivos , Enfermedad Arterial Periférica/cirugía , Enfermedad Arterial Periférica/fisiopatología , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular/efectos adversos , Factores de Tiempo , Resultado del Tratamiento , Persona de Mediana Edad , Extremidad Inferior/irrigación sanguínea , Infección de la Herida Quirúrgica/diagnóstico , Infecciones Relacionadas con Prótesis/cirugía , Infecciones Relacionadas con Prótesis/microbiología , Infecciones Relacionadas con Prótesis/diagnóstico , Factores de Riesgo , Anciano de 80 o más Años , Diseño de Prótesis , Cicatrización de Heridas
3.
J Surg Res ; 284: 6-16, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36527768

RESUMEN

INTRODUCTION: To assess the safety and efficacy of an experimental large-diameter vascular graft externally sealed with an elastomeric polymer when used as an interposition graft in the descending aorta of sheep. METHODS: The experimental vascular grafts as well as control gelatin sealed interposition grafts were inserted into the descending aorta of juvenile sheep. The grafts were assessed by time to hemostasis and blood loss during surgery and hematology and biochemistry panels at distinct time points. Magnetic resonance imaging (MRI) was performed at 3 and at 6 mo after surgery, after which the animals were euthanized and necropsies were carried out including macroscopic and microscopic examination of the grafts, anastomoses, and distal organs. RESULTS: All animals survived the study period. There was no perceivable difference in the surgical handling of the grafts. The median intraoperative blood loss was 27.5 mL (range 10.0-125.0 mL) in the experimental group and 50.0 mL (range 10.0-75.0 mL) in the control group. The median time to hemostasis was 5.0 min (range 2.0-16.0 min) minutes in the experimental group versus 6.0 min (range 4.0-6.0 min) in the control group. MRI showed normal flow and graft patency in both groups. Healing and perianastomotic endothelialization was similar in both groups. CONCLUSIONS: The experimental graft has a similar safety and performance profile and largely comparable necropsy results, in comparison to a commonly used prosthetic vascular graft, with the experimental grafts eliciting a nonadherent external fibrous capsule as the major difference compared to the control grafts that were incorporated into the periadventitia. Survival, hemostatic sealing, and hematologic and radiologic results were comparable between the study groups.


Asunto(s)
Implantación de Prótesis Vascular , Prótesis Vascular , Animales , Ovinos , Implantación de Prótesis Vascular/efectos adversos , Elastómeros , Hemorragia , Grado de Desobstrucción Vascular , Oclusión de Injerto Vascular
4.
Artículo en Inglés | MEDLINE | ID: mdl-37995960

RESUMEN

OBJECTIVE: Current guidelines recommend diameter monitoring of small and asymptomatic abdominal aortic aneurysms (AAAs) due to the low risk of rupture. Elective AAA repair is recommended for diameters ≥ 5.5 cm in men and ≥ 5.0 cm in women. However, data supporting the efficacy of elective treatment for all patients above these thresholds are diverging. For a subgroup of patients, life expectancy might be very short, and elective AAA repair at the current threshold may not be justified. This study aimed to externally validate a predictive model for survival of patients with an asymptomatic AAA treated by endovascular aneurysm repair (EVAR). METHODS: This was a multicentre international retrospective observational cohort study. Data were collected from four European aortic centres treating patients between 2001 and 2021. The initial model included age, estimated glomerular filtration rate (eGFR), and chronic obstructive pulmonary disease (COPD) as independent predictors for survival. Model performance was measured by discrimination and calibration. RESULTS: The validation cohort included 1 500 patients with a median follow up of 65 months, during which 54.6% of the patients died. The external validation showed slightly decreased discrimination ability and signs of overfitting in model calibration. However, a high risk subgroup of patients with impaired survival rates was identified: octogenarians with eGFR < 60 OR COPD, septuagenarians with eGFR < 30, and septuagenarians with eGFR < 60 and COPD having survival rates of only 55.2% and 15.5% at five and 10 years, respectively. CONCLUSION: EVAR is a valuable treatment option for AAA, especially for patients unsuitable for open repair. Nonetheless, not all these patients will benefit from EVAR, and an individualised treatment recommendation should include considerations on life expectancy. This study provides a risk stratification to identify patients who may not benefit from EVAR using the present diameter thresholds.

5.
J Vasc Surg ; 75(6): 1882-1889.e2, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-34627959

RESUMEN

OBJECTIVE: To report the long-term outcome of patients presenting with an aortic, aortoiliac, or isolated common iliac aneurysm treated with the bifurcated EXCLUDER Endoprosthesis. Furthermore, potential differences in late outcome results between the original- and low-permeability endoprosthesis were analyzed. METHODS: A retrospective analysis of prospectively collected data of 182 patients who underwent endovascular aneurysm repair with the EXCLUDER Endoprosthesis between June 1998 and October 2015 in an academic, tertiary care center for aortic disease was performed. Patient follow-up was from 3 to 20 years (mean follow-up of 6.9 years). Primary end points were overall survival and reintervention-free survival. Secondary end points were device-related complications, endoleaks, and reinterventions. RESULTS: Overall survival at 5, 10, and 15 years was 72.8%, 42.1%, and 12.2%, respectively, with no aneurysm-related mortality and no difference in overall survival between the original- vs low-permeability endoprosthesis group (P = .617). Freedom from type I endoleak at 5 years was 94.8%. No new type I endoleak was detected beyond the 5-year follow-up mark. No type III endoleak was identified. Reintervention-free survival was 83.6%, 66.7%, and 66.7% at 5-, 10-, and 15-year follow-up, respectively. There was a significant difference in intervention-free survival between the original- vs low-permeability endoprosthesis group (P = .029) and after the 5-year follow-up mark. In addition, patients with the low-permeability endoprosthesis showed significantly fewer device-related complications (P = .002) and endoleaks (P = .005). CONCLUSIONS: Endovascular aneurysm repair using the EXCLUDER Endoprosthesis is effective and durable on long-term follow-up, with acceptably low device-related complications and reinterventions. The low-permeability endoprosthesis was associated with significantly fewer new device-related complications and endoleaks after 5 years of follow-up.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Aneurisma de la Aorta Abdominal/complicaciones , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/efectos adversos , Endofuga/etiología , Endofuga/cirugía , Procedimientos Endovasculares/efectos adversos , Humanos , Diseño de Prótesis , Estudios Retrospectivos , Stents/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
6.
Eur J Vasc Endovasc Surg ; 63(1): 112-118, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34801385

RESUMEN

OBJECTIVE: The aim of this study was to investigate the efficacy of vascular graft coatings used in the aortic position to prevent vascular graft infection (VGI). METHODS: A systematic review was conducted in accordance with the Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) guidelines using a pre-registered protocol (CRD42020206436). Eligible studies used a vascular graft coating in the aortic position and reported on VGI. A search was performed in MEDLINE (PubMed), Embase, Web of Science, and the Cochrane Library. Primary outcome parameters were VGI, patency, and mortality. Pooled estimates of VGI were calculated using odds ratio (OR) and 95% confidence intervals (CIs) wherever possible. Quality assessment was performed with the Newcastle-Ottawa Assessment Scale and the Revised Cochrane risk of bias tool for randomised trials. RESULTS: In total, 6 873 papers were identified. Only eight studies were included. Six of eight studies (75%) reported on known antimicrobial coating strategies such as antibiotics (n = 3) and silver (n = 3). In the other two studies, polymer coated grafts were used. Only three of eight studies compared coated with uncoated grafts (two antibiotic and one silver). Two randomised controlled trials reported on the effect of rifampicin soaked (1 mg/mL) grafts and showed no significant effect in the early (2 months; OR 0.69, 95% CI 0.29 - 1.62) or late (2 years; OR 0.73, 95% CI 0.23 - 2.32) post-operative periods. A retrospective cohort study focusing on the effect of silver coated grafts did not reveal any advantage (OR 0.19, 95% CI 0.02 - 1.64). Two polymer coated grafts were not considered to have a potential benefit in the prevention of VGIs. CONCLUSION: Clinical studies reporting on the antibacterial effect of vascular graft coatings in the aortic position to prevent VGI are scarce. For silver and antibiotic coatings, no significant protection for VGI was observed. New types of grafts or long acting coating strategies are mandatory to prevent this complication in the future.


Asunto(s)
Antibacterianos/administración & dosificación , Aorta/cirugía , Prótesis Vascular/efectos adversos , Diseño de Prótesis , Infecciones Relacionadas con Prótesis/prevención & control , Plata/administración & dosificación , Injerto Vascular/efectos adversos , Enfermedades de la Aorta/cirugía , Humanos , Polímeros/administración & dosificación
7.
Eur J Vasc Endovasc Surg ; 63(1): 119-137, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34674936

RESUMEN

OBJECTIVE: Vascular graft infection (VGI) is a feared complication. Prevention is of the utmost importance and vascular graft coatings (VGCs) could offer a potential to do this, with in vitro research a first crucial step. The aim of this study was to summarise key features of in vitro models investigating coating strategies to prevent VGI in order to provide guidance for the setup of future translational research. DATA SOURCES: A comprehensive search was performed in MEDLINE, Embase, and Web of Science. METHODS: A systematic review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines. For each database, a specific search strategy was developed. Quality was assessed with the Toxicological data Reliability Assessment Tool (ToxRTool). In vitro models using a VGC and inoculation of the graft with a pathogen were included. The type of graft, coating, and pathogen were summarised. The outcome assessment in each study was evaluated. RESULTS: In total, 4 667 studies were identified, of which 45 papers met the inclusion criteria. The majority used polyester grafts (68.2%). Thirty-one studies (68.9%) included antibiotics, and nine studies (20%) used a commercial silver graft in their protocol. New antibacterial strategies (e.g., proteolytic enzymes) were investigated. A variety of testing methods was found and focused mainly on bacterial adherence, coating adherence and dilution, biofilm formation, and cytotoxicity. Ninety-three per cent of the studies (n = 41) were considered unreliable. CONCLUSION: Polyester is the preferred type of graft to coat on. The majority of coating studies are based on antibiotics; however, new coating strategies (e.g., antibiofilm coating) are coming. Many in vitro setups are available. In vitro studies have great potential, they can limit the use, but cannot replace in vivo studies completely. This paper can be used as a guidance document for future in vitro research.


Asunto(s)
Prótesis Vascular , Diseño de Prótesis , Infecciones Relacionadas con Prótesis/prevención & control , Antibacterianos/administración & dosificación , Humanos , Técnicas In Vitro , Poliésteres , Infecciones Relacionadas con Prótesis/microbiología , Plata/administración & dosificación
8.
Ann Vasc Surg ; 82: 206-211, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34902469

RESUMEN

BACKGROUND: The empiric antibiotic regimen started after deep cultures and explantation of the graft mostly do not cover antifungals. We retrospectively studied the outcome of candida compared to non-candida VGI and assessed whether these results could justify the addition of antifungals to the empiric antibiotics in the early postoperative period. METHODS: All patients treated for infected aorto(ilio)femoral graft with excision and reconstruction at the vascular department of University Hospitals Leuven between January 2010 and 2017 (n = 56) were studied retrospectively. Patients were allocated to the candida group (n = 10) or non-candida group (n = 46) according to the presence of Candida in deep culture isolates. RESULTS: All-cause mortality was significantly higher in the candida group compared to the non-candida group. All-cause 30-day mortality was 40% and 13% for both groups respectively (P = 0.066). At 5 years this was 90% and 46% respectively (P = 0.014). In the candida group 6 patients (60%) had to be revised in the operating room due to bleeding, compared to 5 patients (11%) in the non-candida group (P = 0.002).  Two patients (20%) and 5 patients (11%) had to be readmitted to the ICU, respectively. CONCLUSION: Survival of candida related VGI is significantly worse, especially in the first 5 postoperative months. This could justify the addition of an antifungal to the early empiric postoperative antibiotic cocktail, especially in patients with an aorto-enteric fistula. A cost-benefit analysis could be useful to evaluate the yield.


Asunto(s)
Infecciones Relacionadas con Prótesis , Enfermedades Vasculares , Antibacterianos/efectos adversos , Antifúngicos/uso terapéutico , Prótesis Vascular/efectos adversos , Candida , Humanos , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/microbiología , Infecciones Relacionadas con Prótesis/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Enfermedades Vasculares/etiología
9.
J Vasc Surg ; 74(4): 1386-1393.e1, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34019984

RESUMEN

OBJECTIVE: Vascular graft infection (VGI) is a serious complication with high mortality and morbidity rates. Several measures could be taken to decrease this risk, including the use of silver-containing vascular grafts. However, to date, no clinical advantages have been reported. This study reviews the outcome of preclinical studies focusing on the role of commercially available silver-coated grafts in the prevention of VGI. METHODS: A systematic review was performed with a focus on the preclinical role of commercially available silver-coated vascular grafts in the prevention and treatment of VGI. A comprehensive search was conducted in Medline, Embase, and Web of Science. RESULTS: Nine in vitro and five in vivo studies were included. Two commercial grafts were used (INTERGARD SILVER and Silver Graft). In vitro studies used both gram-positive and gram-negative strains. A positive antimicrobial effect was observed in seven of nine studies (77.8%). A delayed antifungal effect against Candida species was observed in vitro, but disappeared when adding serum proteins. In vivo studies witnessed a microbicidal effect in two out of five studies (40%), but only tested a single causative pathogen (ie, Staphylococcus aureus). CONCLUSIONS: Both in vitro and in vivo studies demonstrated conflicting and mixed results concerning the antimicrobial efficacy of commercially available silver-containing grafts in the prevention of VGI. In general, the study setup was heterogeneous in the different articles. Given the lack of convincing preclinical evidence and their poor performance in clinical studies, more data are needed at this time to guide the appropriate use of silver grafts.


Asunto(s)
Antibacterianos/administración & dosificación , Antifúngicos/administración & dosificación , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Materiales Biocompatibles Revestidos , Procedimientos Endovasculares/instrumentación , Infecciones Relacionadas con Prótesis/prevención & control , Compuestos de Plata/administración & dosificación , Animales , Antibacterianos/toxicidad , Antifúngicos/toxicidad , Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Análisis de Falla de Equipo , Humanos , Modelos Animales , Diseño de Prótesis , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/microbiología , Compuestos de Plata/toxicidad
10.
Eur J Vasc Endovasc Surg ; 62(1): 99-118, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33840577

RESUMEN

OBJECTIVE: Vascular graft infection (VGI) remains an important complication with a high mortality and morbidity rate. Currently, studies focusing on the role of vascular graft coatings in the prevention of VGI are scarce. Therefore, the aims of this study were to survey and summarise key features of pre-clinical in vivo models that have been used to investigate coating strategies to prevent VGI and to set up an ideal model that can be used in future preclinical research. DATA SOURCES: A systematic review was conducted in accordance with the Preferred reporting items for Systematic Reviews and Meta-Analysis guidelines. A comprehensive search was performed in MEDLINE (PubMed), Embase, and Web of Science. REVIEW METHODS: For each database, a specific search strategy was developed. Quality was assessed with the Toxicological data Reliability Assessment Tool (ToxRTool). The type of animal model, graft, coating, and pathogen were summarised. The outcome assessment in each study was evaluated. RESULTS: In total, 4 667 studies were identified, of which 94 papers focusing on in vivo testing were included. Staphylococcus aureus was the organism most used (n = 65; 67.7%). Most of the graft types were polyester grafts. Rifampicin was the most frequently used antibiotic coating (n = 43, 48.3%). In the outcome assessment, most studies mentioned colony forming unit count (n = 88; 91.7%) and clinical outcome (n = 72; 75%). According to the ToxRTool, 21 (22.3%, n = 21/94) studies were considered to be not reliable. CONCLUSION: Currently published in vivo models are very miscellaneous. More attention should be paid to the methodology of these pre-clinical reports when transferring novel graft coatings into clinical practice. Variables used in pre-clinical reports (bacterial strain, duration of activity coating) do not correspond well to current clinical studies. Based on the results of this review, a proposal for a complete and comprehensive set up for pre-clinical invivo testing of anti-infectious properties of vascular graft coatings was defined.


Asunto(s)
Implantación de Prótesis Vascular/efectos adversos , Prótesis Vascular/efectos adversos , Modelos Animales de Enfermedad , Infecciones Relacionadas con Prótesis/prevención & control , Infecciones Estafilocócicas/prevención & control , Animales , Prótesis Vascular/microbiología , Implantación de Prótesis Vascular/instrumentación , Recuento de Colonia Microbiana , Estudios de Factibilidad , Humanos , Pruebas de Sensibilidad Microbiana , Infecciones Relacionadas con Prótesis/microbiología , Reproducibilidad de los Resultados , Rifampin/administración & dosificación , Infecciones Estafilocócicas/microbiología , Staphylococcus aureus/efectos de los fármacos , Staphylococcus aureus/aislamiento & purificación
11.
Ann Vasc Surg ; 71: 437-443, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32890644

RESUMEN

BACKGROUND: Aneurysmal degeneration of medically managed type B aortic dissection (TBAD) can be a life-threatening condition. Preventive thoracic endovascular aorta repair (TEVAR) in patients at risk could potentially be beneficial. The aim of this study was to examine the predictors for late aneurysmal dilatation after TBAD. METHODS: A retrospective study was conducted on 82 patients with medically managed acute TBAD for a minimum of 14 days. Relevant demographic, biochemical, and radiographic variables at presentation were studied. The aortic dissection risk calculator tool developed by Sailer et al., predicting the risk of adverse events after aortic dissection based on demographic and radiographic variables at presentation, was tested retrospectively. RESULTS: With a median follow-up of 36 months (range 13-68), 25 (30.5%) patients underwent surgery (92% TEVAR). A larger initial aortic and false lumen diameter as well as a greater distal extension of the dissection was associated with higher need for surgery (respectively, P = 0.003, P = 0.004, and P = 0.001). We observed higher growth rates of maximum aortic diameter in patients with a greater distal extension of the dissection, larger false lumen diameters and false lumen outflow, and entry tears located at the inner aortic arch (respectively, P = 0.001, P = 0.005, P = 0.001 and P = 0.014). No significant correlations could be found for the risks provided by the calculator tool. CONCLUSIONS: The initial maximum aortic diameter of TBAD is a key predictor for aortic growth. Furthermore, the distal extension of the dissection also seems to play an important role in late aneurysmal degeneration. However, we were not able to confirm the added value of the risk calculator tool in our study group.


Asunto(s)
Aorta Torácica/cirugía , Aneurisma de la Aorta/terapia , Disección Aórtica/terapia , Implantación de Prótesis Vascular , Fármacos Cardiovasculares/uso terapéutico , Procedimientos Endovasculares , Anciano , Disección Aórtica/diagnóstico por imagen , Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta/diagnóstico por imagen , Fármacos Cardiovasculares/efectos adversos , Toma de Decisiones Clínicas , Técnicas de Apoyo para la Decisión , Progresión de la Enfermedad , Procedimientos Endovasculares/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
12.
Ann Vasc Surg ; 75: 445-454, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33823248

RESUMEN

BACKGROUND: This study analyses limb occlusion rates after endovascular aneurysm repair (EVAR) with a strategy including stent-graft limb selection and liberal primary stenting (relining) in anatomies at higher risk for occlusion with uncovered self-expandable or balloon-expandable stents. METHODS: All patients undergoing elective EVAR with a bifurcated stent-graft between January 2010-August 2018 were included. A protocol involving personalized stent-graft selection and liberal primary relining based on preoperative imaging was followed during the whole period. Primary endpoints were technical success and primary limb patency during follow-up. Secondary endpoints included mortality and limb reintervention rates. Risk factors associated to limb patency and reintervention rates were analyzed. RESULTS: Six hundred and fifteen patients (548 males; mean age 72.9 ± 9 years) were included. Overall technical success was 98.5% (606/615). One (0.16%) patient died during the first 30 days. Of the 1230 limbs, 96 (8%) were deemed at risk for occlusion in view of the anatomy, and primarily relined in 62 patients. Estimated primary limb patency at 6 months, 1 year and 3 years was 99.5 ± 0.2%, 99.2 ± 0.3% and 98.5 ± 0.5%, respectively. Freedom from limb-related reintervention at 6 months, 1 year and 3 years was 98.1 ± 0.4%, 97.4 ± 0.5% and 95.6 ± 0.7%, respectively. Only one (1%) of the 96 relined limbs occluded during follow-up. No differences were found in terms of patency or freedom from reintervention between limbs at risk that were primary stented and limbs without adjunctive stents. Gore Excluder stent-grafts presented better patency (Breslow P = 0.005) and lower reintervention rates (Breslow P = 0.001) than other devices during follow-up. Peripheral artery disease was also a risk factor for reintervention (Breslow P = 0.015). CONCLUSION: Liberal use of primary limb relining in patients with iliac anatomy at higher risk for occlusion appears to be a safe and effective strategy to preserve limb patency after EVAR. Gore Excluder graft limbs present better patency and lower reintervention rates than other stent-graft types.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Oclusión de Injerto Vascular/cirugía , Arteria Ilíaca/cirugía , Stents , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/fisiopatología , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Femenino , Oclusión de Injerto Vascular/diagnóstico por imagen , Oclusión de Injerto Vascular/etiología , Oclusión de Injerto Vascular/fisiopatología , Humanos , Arteria Ilíaca/diagnóstico por imagen , Arteria Ilíaca/fisiopatología , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Reoperación , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular
13.
Vascular ; 29(5): 720-722, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33241775

RESUMEN

INTRODUCTION: Omniflow II is promoted as an infection-resistant vascular graft. It is used to treat vascular graft infection; nevertheless, early graft infection has been reported.Report: A 71-year-old patient was treated with an Omniflow II bypass for a non-healing diabetic foot ulcer. Seven months postoperatively, late infection occurred secondary to hematogenous spread from a persistent foot infection. CONCLUSION: We report on the first case of late infection of an Omniflow II vascular graft caused by hematogenous spread. Despite promising results of the Omniflow II graft in the treatment of vascular graft infection, late infection may not be avoided.


Asunto(s)
Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular/efectos adversos , Arteria Femoral/cirugía , Enfermedad Arterial Periférica/cirugía , Arteria Poplítea/cirugía , Infecciones Relacionadas con Prótesis/microbiología , Infecciones Estafilocócicas/microbiología , Staphylococcus aureus/aislamiento & purificación , Anciano , Amputación Quirúrgica , Humanos , Masculino , Diseño de Prótesis , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/cirugía , Infecciones Estafilocócicas/diagnóstico , Infecciones Estafilocócicas/cirugía , Factores de Tiempo , Resultado del Tratamiento
14.
Acta Chir Belg ; 121(5): 333-339, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32644007

RESUMEN

OBJECTIVE: Endoleaks remains a major determinant of outcome after endovascular aortic repair (EVAR) for infrarenal abdominal aortic aneurysms. The objective of this study is to evaluate the long-term impact of proximal type 1 endoleak encountered at the case end of the EVAR procedure or during follow-up. METHODS: All patients treated with EVAR between February 2001 and August 2017 in our institution were included. Data were collected retrospectively. A descriptive analysis of subgroups with type 1a endoleak at case end or with type 1a endoleak first encountered during follow-up was performed. RESULTS: In total, 468 patients were included for analysis. At the case end of the EVAR procedure, in 5.3% (25/468) of patients, a type 1a endoleak was seen. In 72% of cases (18/25) the type 1a endoleak spontaneously disappeared on the first follow-up computed tomography angiography and never recurred. At the end of the follow-up period, no patient in this subgroup died with a type 1a endoleak on follow-up. In 3.4% (16/468) of all cases, a type 1a endoleak was encountered for the first time during follow-up. In 87.5% (14/16) of these cases, reintervention was performed. Two patients died with a persisting type 1a endoleak during follow-up. CONCLUSIONS: Clinicians should differentiate between the type 1a endoleak at the case end and the type 1a endoleak first occurring during follow-up. For type 1a endoleak at the case end, expectant management can be adopted. Delayed type 1a endoleak seen during follow-up rarely seals spontaneously and needs reintervention in the majority of cases.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Aortografía , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Endofuga/diagnóstico por imagen , Endofuga/epidemiología , Endofuga/etiología , Procedimientos Endovasculares/efectos adversos , Humanos , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
15.
J Surg Res ; 252: 37-46, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32222592

RESUMEN

BACKGROUND: Abdominal aortic aneurysm (AAA) is a permanent and irreversible dilation of the lower region of the aorta. It is typically an asymptomatic condition that if left untreated can expand to the point of rupture. In simple mechanical terms, rupture of an artery occurs when the local wall stress exceeds the local wall strength. It is therefore understandable that numerous studies have attempted to estimate the AAA wall stress and investigate the relationship between the AAA wall stress and AAA symptoms. MATERIALS AND METHODS: We conducted computational biomechanics analysis for 19 patients with AAA (a proportion of these patients were classified as symptomatic) to investigate whether the AAA wall stress fields (both the patterns and magnitude) correlate with the clinical definition of symptomatic and asymptomatic AAAs. For computation of AAA wall stress, we used a very efficient method recently presented by the Intelligent Systems for Medicine Laboratory. The Intelligent Systems for Medicine Laboratory's method uses geometry from computed tomography images and mean arterial pressure as the applied load. The method is embedded in the software platform BioPARR-Biomechanics based Prediction of Aneurysm Rupture Risk, freely available from http://bioparr.mech.uwa.edu.au/. The uniqueness of our stress computation approach is three-fold: i) the results are insensitive to unknown patient-specific mechanical properties of arterial wall tissue; ii) the residual stress is accounted for, according to Y.C. Fung's Uniform Stress Hypothesis; and iii) the analysis is automated and quick, making our approach compatible with clinical workflows. RESULTS: Symptomatic patients could not be identified from the plots (pattern) of AAA wall stress and stress magnitude. Although the largest stress was predicted for a patient who suffered from AAA symptoms, the three patients with the smallest stress were also symptomatic. CONCLUSIONS: The results demonstrate, contrary to the common view, that neither the wall stress magnitude nor the stress distribution appears to be associated with the presence of clinical symptoms.


Asunto(s)
Aorta Abdominal/fisiopatología , Aneurisma de la Aorta Abdominal/diagnóstico , Rotura de la Aorta/prevención & control , Modelos Cardiovasculares , Estrés Mecánico , Anciano , Anciano de 80 o más Años , Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/complicaciones , Aneurisma de la Aorta Abdominal/fisiopatología , Rotura de la Aorta/etiología , Rotura de la Aorta/fisiopatología , Enfermedades Asintomáticas , Simulación por Computador , Femenino , Análisis de Elementos Finitos , Humanos , Masculino , Persona de Mediana Edad , Modelación Específica para el Paciente , Estudios Retrospectivos , Medición de Riesgo/métodos , Programas Informáticos , Tomografía Computarizada por Rayos X
16.
Ann Vasc Surg ; 63: 129-135, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31536793

RESUMEN

BACKGROUND: To report mid-term to long-term outcome data for endovascular aortic repair using the Ovation stent-graft system (Endologix, Santa Rosa, CA) in a single university center. METHODS: All patients treated with the Ovation stent graft between February 2012 and January 2019 were included. Patient demographics, anatomical and operative details, as well as follow-up data including complications, need for further interventions, and mortality were analyzed. RESULTS: A total of 74 patients (93% males; mean age, 74.5 years) were treated with the Ovation stent graft. The median maximal aortic diameter was 60 mm (range, 36-100). Sixty-two of 74 patients (83.8%) were considered to have a hostile neck. About 33% had a (reversed) conical neck, 59% had circumferential neck calcification (>50%), and 39% had significant neck thrombus (>50%). Technical success rate was 91.89%. Despite additional measures, 4 patients had a persistent type Ia endoleak on completion angiography, of which 3 disappeared on the first postoperative computed tomography angiography. Mean follow-up duration was 31.62 months ± 21.3 (range, 0-72.74 months). Twenty-four patients had a follow-up time of at least 36 months. Freedom from reintervention at 1, 2, 3, and 5 years was 92.7%, 90.8%, 80.1%, and 80.1%, respectively. Estimated freedom from mortality at 1, 2, 3, and 5 years was 96.8%, 95.0%, 87.3%, and 68.5%, respectively. No late type Ia or type III endoleak was detected during follow-up. No aneurysm-related mortality was seen. CONCLUSIONS: Our mid- to long-term experience with the Ovation stent-graft system demonstrates safe and durable results without late type Ia or type III endoleak.


Asunto(s)
Aneurisma de la Aorta/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Stents , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta/diagnóstico por imagen , Aneurisma de la Aorta/mortalidad , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Endofuga/etiología , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Femenino , Humanos , Masculino , Supervivencia sin Progresión , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo
18.
Ann Vasc Surg ; 56: 340-344, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30476607

RESUMEN

Endovascular treatment of both type A and type B aortic dissections complicated by organ malperfusion is gaining increasing interest and evidence. Different fenestration techniques of the dissection membrane have already been described. We present a 53-year-old patient with complicated type A aortic dissection after previous repair of the ascending aorta. The patient was treated with dissection membrane fenestration and "cheese-wire" technique. Owing to the mobility of the dissection flap, we encountered problems to perforate the dissection membrane with the use of a needle. Finally, on transesophageal echocardiography (TEE), a small dynamic dissection flap was visualized in the aortic arch, which could be catheterized by TEE for guidance. Downward traction of the through-wire caused infrarenal intima accumulation. Iliac outflow obstruction could be solved by placement of a bare-metal stent. Extensive screening for dynamic dissection of (re)-entry holes with the use of TEE is a valuable auxiliary in case needle perforation is difficult to achieve in complicated type A or B dissections.


Asunto(s)
Aneurisma de la Aorta/cirugía , Disección Aórtica/cirugía , Implantación de Prótesis Vascular/métodos , Cateterismo Periférico/métodos , Ecocardiografía Doppler en Color , Ecocardiografía Transesofágica , Procedimientos Endovasculares/métodos , Isquemia/etiología , Vísceras/irrigación sanguínea , Disección Aórtica/complicaciones , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/fisiopatología , Aneurisma de la Aorta/complicaciones , Aneurisma de la Aorta/diagnóstico por imagen , Aneurisma de la Aorta/fisiopatología , Aortografía/métodos , Implantación de Prótesis Vascular/efectos adversos , Cateterismo Periférico/efectos adversos , Angiografía por Tomografía Computarizada , Procedimientos Endovasculares/efectos adversos , Resultado Fatal , Humanos , Isquemia/diagnóstico por imagen , Isquemia/fisiopatología , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Flujo Sanguíneo Regional , Daño por Reperfusión/etiología , Daño por Reperfusión/fisiopatología , Resultado del Tratamiento
19.
Eur J Vasc Endovasc Surg ; 65(3): 413, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36464222
20.
Eur J Vasc Endovasc Surg ; 55(5): 640-646, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29545020

RESUMEN

OBJECTIVES: Visceral arteries in fenestrated and branched endovascular repair (F/BEVAR) have been addressed by fenestrations or directional side branches. Inner branches, as used in the arch branched device, could provide an extra option for visceral arteries "unsuitable" for fenestrations or directional side branches. Early experience with the use of inner branches for visceral arteries in F/BEVAR is described. METHODS: All consecutive patients treated by F/BEVAR for complex abdominal aortic aneurysm (AAA) or thoraco-abdominal aneurysm (TAAA) using stent grafts with inner branches were included. Data were collected prospectively. RESULTS: Thirty-two patients (28 male, mean age 71.6 ± 8.3 years) were included. Seven (21.9%) patients had a complex AAA and 25 (78.1%) had a TAAA. A stent graft with inner branches only was used in four (12.5%) patients. The remaining 28 (87.5%) patients received a stent graft with fenestrations and inner branches. In total 52 vessels were targeted with inner branches. Technical success was achieved in all 32 (100%) patients. All 38 inner branch target vessels in grafts including fenestrations and inner branches were instantly catheterised (<1 minute), whereas catheterisation of target vessels in "inner branch only" grafts proved more difficult (<1 minute, n = 3; 1-3 min, n = 4; and >3 min, n = 7). The 30 day operative mortality was 3.1% (1/32). Estimated survival at 1 year was 80.0% ± 8.3%. During follow-up, four renal inner branches occluded in three patients. The estimated inner branch target vessel stent patency at 1 year was 91.9 ± 4.5%. The estimated freedom from re-intervention at 1 year was 78.4% ± 8.9%. CONCLUSIONS: Early data suggest that visceral inner branches might represent a feasible third option to address selected target vessels in F/BEVAR. Stent grafts with inner branch(es) in combination with fenestrations seem to be a better configuration than stent grafts with inner branches alone. Durability of the inner branch design needs further investigation.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Torácica/cirugía , Stents , Injerto Vascular/métodos , Anciano , Aneurisma de la Aorta Abdominal/mortalidad , Aneurisma de la Aorta Torácica/mortalidad , Prótesis Vascular , Arteria Celíaca/cirugía , Femenino , Estudios de Seguimiento , Humanos , Tiempo de Internación , Masculino , Arteria Mesentérica Superior/cirugía , Complicaciones Posoperatorias , Arteria Renal/cirugía , Estudios Retrospectivos , Injerto Vascular/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA