Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Interv Cardiol ; 31(3): 391-399, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29696693

RESUMEN

OBJECTIVES: We sought to compare using serial CMR, the quantity of AR and associated valve hemodynamics, following the first-generation CoreValve (Medtronic, Minneapolis, MN) and the second-generation Lotus valve (Boston Scientific, Natick, MA). BACKGROUND: Aortic regurgitation (AR) following Transcatheter Aortic Valve Replacement (TAVR) confers a worse prognosis and can be accurately quantified using cardiovascular magnetic resonance (CMR). Second generation valves have been specifically designed to reduce paravalvular AR and improve clinical outcomes. METHODS: Fifty-one patients (79.0 ± 7.7 years, 57% male) were recruited and imaged at three time points: immediately pre- and post-TAVR, and at 6 months. RESULTS: CMR-derived AR fraction immediately post-TAVR was greater in the CoreValve compared to Lotus group (11.7 ± 8.4 vs. 4.3 ± 3.4%, P = 0.001), as was the frequency of ≥moderate AR (9/24 (37.5%) versus 0/27, P < 0.001). However, at 6 months AR fraction had improved significantly in the CoreValve group such that the two valve designs were comparable (6.4 ± 5.0 vs 5.6 ± 5.3%, P = 0.623), with no patient in either group having ≥moderate AR. The residual peak pressure gradient immediately following TAVR was significantly lower with CoreValve compared to Lotus (14.1 ± 5.6 vs 25.4 ± 11.6 mmHg, P = 0.001), but again by 6 months the two valve designs were comparable (16.5 ± 9.4 vs 19.7 ± 10.5 mmHg, P = 0.332). There was no difference in the degree of LV reverse remodeling between the two valves at 6 months. CONCLUSION: Immediately post-TAVR, there was significantly less AR but a higher residual peak pressure gradient with the Lotus valve compared to CoreValve. However, at 6 months both devices had comparable valve hemodynamics and LV reverse remodeling.


Asunto(s)
Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Imagen por Resonancia Magnética , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/complicaciones , Femenino , Hemodinámica , Humanos , Masculino , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Resultado del Tratamiento
2.
J Cardiovasc Magn Reson ; 19(1): 13, 2017 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-28173819

RESUMEN

BACKGROUND: It is unknown whether circumferential strain is associated with prognosis after treatment of aortic stenosis (AS). We aimed to characterise strain in severe AS, using myocardial tagging cardiovascular magnetic resonance (CMR), prior to and following Transcatheter Aortic Valve Implantation (TAVI) and Surgical Aortic Valve Replacement (SAVR), and determine whether abnormalities in strain were associated with outcome. METHODS: CMR was performed pre- and 6 m post-intervention in 98 patients (52 TAVI, 46 SAVR; 77 ± 8 years) with severe AS. TAVI patients were older (80.9 ± 6.4 vs. 73.0 ± 7.0 years, p < 0.01) with a higher STS score (2.06 ± 0.6 vs. 6.03 ± 3.4, p < 0.001). Tagged cine images were acquired at the basal, mid and apical LV levels with a complementary spatial modulation of magnetization (CSPAMM) pulse sequence. Circumferential strain, strain rate and rotation were calculated using inTag© software. RESULTS: No significant change in basal or mid LV circumferential strain, or of diastolic strain rate, was seen following either intervention. However, a significant and comparable decline in LV torsion and twist was observed (SAVR: torsion 14.08 ± 8.40 vs. 7.81 ± 4.51, p < 0.001, twist 16.17 ± 7.01 vs.12.45 ± 4.78, p < 0.01; TAVI: torsion 14.43 ± 4.66 vs. 11.20 ± 4.62, p < 0.001, twist 16.08 ± 5.36 vs. 12.36 ± 5.21, p < 0.001) which likely reflects an improvement towards normal physiology following relief of AS. Over a maximum 6.0y follow up, there were 23 (16%) deaths following valve intervention. On multivariable Cox analysis, baseline mid LV circumferential strain was significantly associated with all-cause mortality (hazard ratio, 1.03; 1.01-1.05; p = 0.009) independent of age, LV ejection fraction and STS mortality risk score. ROC analysis indicated a mid LV circumferential strain > -18.7% was associated with significantly reduced survival. CONCLUSION: TAVI and SAVR procedures are associated with comparable declines in rotational LV mechanics at 6 m, with largely unchanged strain and strain rates. Pre-operative peak mid LV circumferential strain is associated with post-operative mortality.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Imagen por Resonancia Cinemagnética , Contracción Miocárdica , Función Ventricular Izquierda , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Área Bajo la Curva , Fenómenos Biomecánicos , Distribución de Chi-Cuadrado , Inglaterra , Femenino , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Interpretación de Imagen Asistida por Computador , Estimación de Kaplan-Meier , Masculino , Análisis Multivariante , Valor Predictivo de las Pruebas , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Curva ROC , Recuperación de la Función , Factores de Riesgo , Índice de Severidad de la Enfermedad , Programas Informáticos , Estrés Mecánico , Volumen Sistólico , Torsión Mecánica , Reemplazo de la Válvula Aórtica Transcatéter , Resultado del Tratamiento
3.
Curr Heart Fail Rep ; 14(5): 365-375, 2017 10.
Artículo en Inglés | MEDLINE | ID: mdl-28762172

RESUMEN

PURPOSE OF REVIEW: Cardiogenic shock from decompensated heart failure is associated with significant morbidity and mortality. Mechanical circulatory support (MCS) improves haemodynamics and reverses organ dysfunction in critically ill patients with cardiogenic shock. This paper summarises the main modalities of mechanical support and their physiological impact, practical considerations, advantages and disadvantages to facilitate a holistic approach in managing a potentially lethal pathology. RECENT FINDINGS: To date, there remains a lack of large randomised controlled trials to support the use of any mechanical support strategy. Consequently, meta-analyses, registry data and expert consensus in the form of society guidelines are relied upon. Currently, randomised trials are in progress to assess the efficacy of a percutaneous assist device (Impella) and extracorporeal membrane oxygenation. Mechanical support options are centred around the use of counter pulsation and percutaneous assist devices and the use of an extracorporeal pump and are hence varied in means of application, degree of haemodynamic benefit and potential complications. Regardless of future innovations, a timely multidisciplinary approach that incorporates both patient and institutional considerations will always be crucial to a successful outcome.


Asunto(s)
Oxigenación por Membrana Extracorpórea/métodos , Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Hemodinámica/fisiología , Insuficiencia Cardíaca/fisiopatología , Humanos
4.
J Cardiovasc Magn Reson ; 18(1): 37, 2016 06 10.
Artículo en Inglés | MEDLINE | ID: mdl-27287000

RESUMEN

BACKGROUND: Aortic stiffness is increasingly used as an independent predictor of adverse cardiovascular outcomes. We sought to compare the impact of transcatheter aortic valve implantation (TAVI) and surgical aortic valve replacement (SAVR) upon aortic vascular function using cardiovascular magnetic resonance (CMR) measurements of aortic distensibility and pulse wave velocity (PWV). METHODS AND RESULTS: A 1.5 T CMR scan was performed pre-operatively and at 6 m post-intervention in 72 patients (32 TAVI, 40 SAVR; age 76 ± 8 years) with high-risk symptomatic severe aortic stenosis. Distensibility of the ascending and descending thoracic aorta and aortic pulse wave velocity were determined at both time points. TAVI and SAVR patients were comparable for gender, blood pressure and left ventricular ejection fraction. The TAVI group were older (81 ± 6.3 vs. 72.8 ± 7.0 years, p < 0.05) with a higher EuroSCORE II (5.7 ± 5.6 vs. 1.5 ± 1.0 %, p < 0.05). At 6 m, SAVR was associated with a significant decrease in distensibility of the ascending aorta (1.95 ± 1.15 vs. 1.57 ± 0.68 × 10(-3)mmHg(-1), p = 0.044) and of the descending thoracic aorta (3.05 ± 1.12 vs. 2.66 ± 1.00 × 10(-3)mmHg(-1), p = 0.018), with a significant increase in PWV (6.38 ± 4.47 vs. 11.01 ± 5.75 ms(-1), p = 0.001). Following TAVI, there was no change in distensibility of the ascending aorta (1.96 ± 1.51 vs. 1.72 ± 0.78 × 10(-3)mmHg(-1), p = 0.380), descending thoracic aorta (2.69 ± 1.79 vs. 2.21 ± 0.79 × 10(-3)mmHg(-1), p = 0.181) nor in PWV (8.69 ± 6.76 vs. 10.23 ± 7.88 ms(-1), p = 0.301) at 6 m. CONCLUSIONS: Treatment of symptomatic severe aortic stenosis by SAVR but not TAVI was associated with an increase in aortic stiffness at 6 months. Future work should focus on the prognostic implication of these findings to determine whether improved patient selection and outcomes can be achieved.


Asunto(s)
Aorta Torácica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas , Imagen por Resonancia Cinemagnética , Reemplazo de la Válvula Aórtica Transcatéter , Rigidez Vascular , Anciano , Anciano de 80 o más Años , Aorta Torácica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Inglaterra , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Masculino , Valor Predictivo de las Pruebas , Estudios Prospectivos , Análisis de la Onda del Pulso , Índice de Severidad de la Enfermedad , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
5.
J Am Coll Cardiol ; 75(3): 304-316, 2020 01 28.
Artículo en Inglés | MEDLINE | ID: mdl-31976869

RESUMEN

BACKGROUND: Myocardial fibrosis is a key mechanism of left ventricular decompensation in aortic stenosis and can be quantified using cardiovascular magnetic resonance (CMR) measures such as extracellular volume fraction (ECV%). Outcomes following aortic valve intervention may be linked to the presence and extent of myocardial fibrosis. OBJECTIVES: This study sought to determine associations between ECV% and markers of left ventricular decompensation and post-intervention clinical outcomes. METHODS: Patients with severe aortic stenosis underwent CMR, including ECV% quantification using modified Look-Locker inversion recovery-based T1 mapping and late gadolinium enhancement before aortic valve intervention. A central core laboratory quantified CMR parameters. RESULTS: Four-hundred forty patients (age 70 ± 10 years, 59% male) from 10 international centers underwent CMR a median of 15 days (IQR: 4 to 58 days) before aortic valve intervention. ECV% did not vary by scanner manufacturer, magnetic field strength, or T1 mapping sequence (all p > 0.20). ECV% correlated with markers of left ventricular decompensation including left ventricular mass, left atrial volume, New York Heart Association functional class III/IV, late gadolinium enhancement, and lower left ventricular ejection fraction (p < 0.05 for all), the latter 2 associations being independent of all other clinical variables (p = 0.035 and p < 0.001). After a median of 3.8 years (IQR: 2.8 to 4.6 years) of follow-up, 52 patients had died, 14 from adjudicated cardiovascular causes. A progressive increase in all-cause mortality was seen across tertiles of ECV% (17.3, 31.6, and 52.7 deaths per 1,000 patient-years; log-rank test; p = 0.009). Not only was ECV% associated with cardiovascular mortality (p = 0.003), but it was also independently associated with all-cause mortality following adjustment for age, sex, ejection fraction, and late gadolinium enhancement (hazard ratio per percent increase in ECV%: 1.10; 95% confidence interval [1.02 to 1.19]; p = 0.013). CONCLUSIONS: In patients with severe aortic stenosis scheduled for aortic valve intervention, an increased ECV% is a measure of left ventricular decompensation and a powerful independent predictor of mortality.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Líquido Extracelular/fisiología , Volumen Sistólico/fisiología , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/fisiopatología , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/mortalidad , Femenino , Estudios de Seguimiento , Humanos , Estudios Longitudinales , Imagen por Resonancia Cinemagnética/métodos , Masculino , Persona de Mediana Edad , Mortalidad/tendencias , Miocardio/patología , Estudios Prospectivos , Disfunción Ventricular Izquierda/mortalidad
6.
Heart ; 105(23): 1818-1824, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31467152

RESUMEN

OBJECTIVES: To investigate sex differences in left ventricular remodelling and outcome in patients undergoing surgical or transcatheter aortic valve replacement (SAVR/TAVR). METHODS: In this multicentre, observational, outcome study with imaging core-lab analysis, patients with severe aortic stenosis (AS) listed for intervention at one of six UK centres were prospectively recruited and underwent cardiovascular magnetic resonance imaging. The primary endpoint was all-cause mortality and secondary endpoint was cardiovascular mortality. RESULTS: 674 patients (425 men, 249 women, age 75±14 years) were included: 399 SAVR, 275 TAVR. Women were older, had higher surgical risk scores and underwent TAVR more frequently (53% vs 33.6%, p<0.001). More men had bicuspid aortic valves (BAVs) (26.7% vs 14.9%, p<0.001) and demonstrated more advanced remodelling than women. During a median follow-up of 3.6 years, 145 (21.5%) patients died, with no significant sex difference in all-cause mortality (23.3% vs 20.5%, p=0.114), but higher cardiovascular mortality in women (13.7% vs 8.5%, p=0.012). There were no significant sex-related differences in outcome in the SAVR or TAVR subgroups, or after excluding those with BAV. Factors independently associated with all-cause mortality were age, left ventricular ejection fraction (LVEF), BAV (better) and myocardial fibrosis detected with late gadolinium enhancement (LGE) in men, and age, LVEF and LGE in women. Age and LGE were independently associated with cardiovascular mortality in both sexes. CONCLUSIONS: Men demonstrate more advanced remodelling in response to a similar severity of AS. The higher cardiovascular mortality observed in women following AVR is accounted for by women having less BAV and higher risk scores resulting in more TAVR. LGE is associated with a worse prognosis in both sexes.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Miocardio/patología , Caracteres Sexuales , Remodelación Ventricular/fisiología , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Ecocardiografía , Femenino , Fibrosis , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Estimación de Kaplan-Meier , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Periodo Posoperatorio , Pronóstico , Reino Unido/epidemiología
7.
BMJ Open ; 9(1): e022329, 2019 01 21.
Artículo en Inglés | MEDLINE | ID: mdl-30670503

RESUMEN

OBJECTIVE: To compare the incidence of silent cerebral infarction and impact on cognitive function following transcatheter aortic valve implantation (TAVI) with the first-generation CoreValve (Medtronic, Minneapolis, Minnesota, USA) and second-generation Lotus valve (Boston Scientific, Natick Massachusetts, USA). DESIGN: A prospective observational study comprising a 1.5 T cerebral MRI scan, performed preoperatively and immediately following TAVI, and neurocognitive assessments performed at baseline, 30 days and 1 year follow-up. SETTING: University hospitals of Leeds and Leicester, UK. PATIENTS: 66 (80.6±8.0 years, 47% male) patients with high-risk severe symptomatic aortic stenosis recruited between April 2012 and May 2015. MAIN OUTCOME MEASURES: Incidence of new cerebral microinfarction and objective decline in neurocognitive performance. RESULTS: All underwent cerebral MRI at baseline and immediately following TAVI, and 49 (25 Lotus, 24 CoreValve) completed neurocognitive assessments at baseline, 30 days and 1 year. There was a significantly greater incidence of new cerebral microinfarction observed following the Lotus TAVI (23 (79%) vs 22 (59%), p=0.025) with a greater number of new infarcts per patient (median 3.5 (IQR 7.0) vs 2.0 (IQR 3.0), p=0.002). The mean volume of infarcted cerebral tissue per patient was equivalent following the two prostheses (p=0.166). More patients suffered new anterior (14 (48%) vs 2 (5%), p=0.001) and vertebrobasilar (15 (52%) vs 7 (19%), p=0.005) lesions following Lotus. Lotus was associated with a decline in verbal memory and psychomotor speed at 30 days. However, performance longitudinally at 1 year was preserved in all neurocognitive domains. CONCLUSIONS: There was a higher incidence of silent cerebral microinfarction and a greater number of lesions per patient following Lotus compared with CoreValve. However, there was no objective decline in neurocognitive function discernible at 1 year following TAVI with either prosthesis.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Infarto Cerebral/fisiopatología , Cognición , Prótesis Valvulares Cardíacas/clasificación , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Infarto Cerebral/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética , Femenino , Humanos , Masculino , Pruebas de Estado Mental y Demencia , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento , Reino Unido
8.
Eur Heart J Cardiovasc Imaging ; 19(7): 816-823, 2018 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-29029139

RESUMEN

Aims: To test the hypothesis that patients with ischaemic cardiomyopathy (ICM) and non-ischaemic cardiomyopathy (NICM) have different torsion and strain parameters, and compare to healthy, age-matched controls. VINDICATE investigated efficacy of high-dose vitamin D on patients with heart failure (HF) secondary to left ventricular (LV) systolic dysfunction of any aetiology. It is important to differentiate ICM and NICM as treatment and prognosis varies significantly. Cardiovascular magnetic resonance (CMR) reliably determines aetiology of HF and tissue tagging techniques are recognized as the reference standard measures of strain and torsion. Methods and results: Fifty three patients (31 ICM, 22 NICM) from VINDICATE and 25 controls underwent CMR at 3.0T, including cine imaging in multiple planes and tissue tagging by spatial modulation of magnetization. CMR data were analysed blinded, by quantitatively reporting circumferential strain and torsion from tagged images and global longitudinal strain from feature tracking. HF patients had larger ventricles indexed to body surface area, lower left ventricular ejection fraction (LVEF), LV torsion, twist, and strain parameters compared to controls. There were no significant differences between ICM and NICM in age, blood pressure, heart rhythm, or NYHA status. There was no significant difference in LV dimensions, EF, and strain parameters between ICM and NICM. NICM patients had significantly lower LV twist (6.0 ± 3.7° vs. 8.8 ± 4.3°, P = 0.023) and torsion (5.9 ± 3.5° vs. 8.8 ± 4.7°, P = 0.017) compared to ICM. Conclusion: Twist, torsion, and strain are reduced in HF patients compared to controls. Torsion and twist are significantly lower in patients with NICM compared to ICM, despite similar volumetric dimensions, circumferential and longitudinal strain parameters, and LVEF.


Asunto(s)
Cardiomiopatías/diagnóstico por imagen , Insuficiencia Cardíaca/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador , Imagen por Resonancia Cinemagnética/métodos , Isquemia Miocárdica/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Cardiomiopatías/etiología , Cardiomiopatías/fisiopatología , Estudios de Casos y Controles , Estudios de Evaluación como Asunto , Femenino , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/complicaciones , Isquemia Miocárdica/fisiopatología , Pronóstico , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Torsión Mecánica , Remodelación Ventricular/fisiología
9.
JACC Cardiovasc Imaging ; 10(9): 989-999, 2017 09.
Artículo en Inglés | MEDLINE | ID: mdl-27771398

RESUMEN

OBJECTIVES: In the setting of reperfused acute myocardial infarction (AMI), the authors sought to compare prediction of contractile recovery by infarct extracellular volume (ECV), as measured by T1-mapping cardiac magnetic resonance (CMR), with late gadolinium enhancement (LGE) transmural extent. BACKGROUND: The transmural extent of myocardial infarction as assessed by LGE CMR is a strong predictor of functional recovery, but accuracy of the technique may be reduced in AMI. ECV mapping by CMR can provide a continuous measure associated with the severity of tissue damage within infarcted myocardium. METHODS: Thirty-nine patients underwent acute (day 2) and convalescent (3 months) CMR scans following AMI. Cine imaging, tissue tagging, T2-weighted imaging, modified Look-Locker inversion T1 mapping natively and 15 min post-gadolinium-contrast administration, and LGE imaging were performed. The ability of acute infarct ECV and acute transmural extent of LGE to predict convalescent wall motion, ejection fraction (EF), and strain were compared per-segment and per-patient. RESULTS: Per-segment, acute ECV and LGE transmural extent were associated with convalescent wall motion score (p < 0.01; p < 0.01, respectively). ECV had higher accuracy than LGE extent to predict improved wall motion (area under receiver-operating characteristics curve 0.77 vs. 0.66; p = 0.02). Infarct ECV ≤0.5 had sensitivity 81% and specificity 65% for prediction of improvement in segmental function; LGE transmural extent ≤0.5 had sensitivity 61% and specificity 71%. Per-patient, ECV and LGE correlated with convalescent wall motion score (r = 0.45; p < 0.01; r = 0.41; p = 0.02, respectively) and convalescent EF (p < 0.01; p = 0.04). ECV and LGE extent were not significantly correlated (r = 0.34; p = 0.07). In multivariable linear regression analysis, acute infarct ECV was independently associated with convalescent infarct strain and EF (p = 0.03; p = 0.04), whereas LGE was not (p = 0.29; p = 0.24). CONCLUSIONS: Acute infarct ECV in reperfused AMI can complement LGE assessment as an additional predictor of regional and global LV functional recovery that is independent of transmural extent of infarction.


Asunto(s)
Imagen por Resonancia Cinemagnética , Contracción Miocárdica , Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST/diagnóstico por imagen , Infarto del Miocardio con Elevación del ST/terapia , Función Ventricular Izquierda , Anciano , Área Bajo la Curva , Medios de Contraste/administración & dosificación , Femenino , Humanos , Modelos Lineales , Masculino , Persona de Mediana Edad , Análisis Multivariante , Valor Predictivo de las Pruebas , Estudios Prospectivos , Curva ROC , Recuperación de la Función , Reproducibilidad de los Resultados , Infarto del Miocardio con Elevación del ST/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
10.
Quant Imaging Med Surg ; 6(3): 259-73, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27429910

RESUMEN

Degenerative aortic stenosis (AS) is the most common valvular disease in the western world with a prevalence expected to double within the next 50 years. International guidelines advocate the use of cardiovascular magnetic resonance (CMR) as an investigative tool, both to guide diagnosis and to direct optimal treatment. CMR is the reference standard for quantifying both left and right ventricular volumes and mass, which is essential to assess the impact of AS upon global cardiac function. Given the ability to image any structure in any plane, CMR offers many other diagnostic strengths including full visualisation of valvular morphology, direct planimetry of orifice area, the quantification of stenotic jets and in particular, accurate quantification of valvular regurgitation. In addition, CMR permits reliable and accurate measurements of the aortic root and arch which can be fundamental to appropriate patient management. There is a growing evidence base to indicate tissue characterisation using CMR provides prognostic information, both in asymptomatic AS patients and those undergoing intervention. Furthermore, a number of current clinical trials will likely raise the importance of CMR in routine patient management. This article will focus on the incremental value of CMR in the assessment of severe AS and the insights it offers following valve replacement.

11.
Open Heart ; 3(1): e000337, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27175286

RESUMEN

BACKGROUND: Microvascular obstruction (MVO) and intramyocardial haemorrhage (IMH) are associated with adverse prognosis, independently of infarct size after reperfused ST-elevation myocardial infarction (STEMI). Mitral annular plane systolic excursion (MAPSE) is a well-established parameter of longitudinal function on echocardiography. OBJECTIVE: We aimed to investigate how acute MAPSE, assessed by a four-chamber cine-cardiovascular MR (CMR), is associated with MVO, IMH and convalescent left ventricular (LV) remodelling. METHODS: 54 consecutive patients underwent CMR at 3T (Intera CV, Philips Healthcare, Best, The Netherlands) within 3 days of reperfused STEMI. Cine, T2-weighted, T2* and late gadolinium enhancement (LGE) imaging were performed. Infarct and MVO extent were measured from LGE images. The presence of IMH was investigated by combined analysis of T2w and T2* images. Averaged-MAPSE (medial-MAPSE+lateral-MAPSE/2) was calculated from 4-chamber cine imaging. RESULTS: 44 patients completed the baseline scan and 38 patients completed 3-month scans. 26 (59%) patients had MVO and 25 (57%) patients had IMH. Presence of MVO and IMH were associated with lower averaged-MAPSE (11.7±0.4 mm vs 9.3±0.3 mm; p<0.001 and 11.8±0.4 mm vs 9.2±0.3 mm; p<0.001, respectively). IMH (ß=-0.655, p<0.001) and MVO (ß=-0.567, p<0.001) demonstrated a stronger correlation to MAPSE than other demographic and infarct characteristics. MAPSE ≤10.6 mm demonstrated 89% sensitivity and 72% specificity for the detection of MVO and 92% sensitivity and 74% specificity for IMH. LV remodelling in convalescence was not associated with MAPSE (AUC 0.62, 95% CI 0.44 to 0.77, p=0.22). CONCLUSIONS: Postreperfused STEMI, LV longitudinal function assessed by MAPSE can independently predict the presence of MVO and IMH.

12.
Int J Cardiol ; 223: 639-644, 2016 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-27565842

RESUMEN

OBJECTIVE: The response of the RV following treatment of aortic stenosis is poorly defined, reflecting the challenge of accurate RV assessment. Cardiovascular magnetic resonance (CMR) is the established reference for imaging of RV volumes, mass and function. We sought to define the impact of transcatheter aortic valve implantation (TAVI) and surgical aortic valve replacement (SAVR) upon RV function in patients treated for severe aortic stenosis using CMR. METHODS: A 1.5T CMR scan was performed preoperatively and 6months postoperatively in 112 (56 TAVI, 56 SAVR; 76±8years) high-risk severe symptomatic aortic stenosis patients across two UK cardiothoracic centres. RESULTS: TAVI patients were older (80.4±6.7 vs. 72.8±7.2years, p<0.05) with a higher STS score (2.13±0.73 vs. 5.54±3.41%, p<0.001). At 6months, SAVR was associated with a significant increase in RV end systolic volume (33±10 vs. 37±10ml/m2, p=0.008), and decrease in RV ejection fraction (58±8 vs. 53±8%, p=0.005) and tricuspid annular plane systolic excursion (22±5 vs. 14±3mm, p<0.001). Only 4 (7%) SAVR patients had new RV late gadolinium hyper-enhancement with no new cases seen in the TAVI patients at 6months. Longer surgical cross-clamp time was the only predictor of increased RV end systolic volume at 6months. Post-TAVI, there was no observed change in RV volumes or function. Over a maximum 6.3year follow-up, 18(32%) of TAVI patients and 1(1.7%) of SAVR patients had died (p=0.001). On multivariable Cox analysis, the RV mass at 6m post-TAVI was independently associated with all-cause mortality (HR 1.359, 95% CI 1.108-1.666, p=0.003). CONCLUSIONS: SAVR results in a deterioration in RV systolic volumes and function associated with longer cross-clamp times and is not fully explained by suboptimal RV protection during cardiopulmonary bypass. TAVI had no adverse impact upon RV volumes or function.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Imagen por Resonancia Cinemagnética/tendencias , Reemplazo de la Válvula Aórtica Transcatéter/tendencias , Función Ventricular Derecha/fisiología , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/mortalidad , Femenino , Estudios de Seguimiento , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Implantación de Prótesis de Válvulas Cardíacas/tendencias , Humanos , Imagen por Resonancia Cinemagnética/mortalidad , Masculino , Mortalidad/tendencias , Estudios Prospectivos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad
13.
Circ Cardiovasc Interv ; 8(3): e001913, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25737407

RESUMEN

BACKGROUND: Incidence of cerebral microinfarcts is higher after transcatheter aortic valve implantation (TAVI) compared with surgical aortic valve replacement (SAVR). It is unknown whether these lesions persist and what direct impact they have on health-related quality of life. The objective was to identify predictors of cerebral microinfarction and measure their effect on health-related quality of life during 6 months after TAVI when compared with SAVR. METHODS AND RESULTS: Cerebral MRI was conducted at baseline, post procedure, and 6 months using diffusion-weighted imaging. Health-related quality of life was measured at baseline, 30 days, and 6 months with short form-12 health outcomes and EuroQol 5 dimensions questionnaires. One hundred eleven patients (TAVI, n=71; SAVR, n=40) were studied. The incidence (54 [77%] versus 17 [43%]; P=0.001) and number (3.4±4.9 versus 1.2±1.8; P=0.001) of new microinfarcts were greater after TAVI than after SAVR. The total volume per microinfarct was smaller in TAVI than in SAVR (0.23±0.24 versus 0.76±1.8 mL; P=0.04). The strongest associations for microinfarction were: TAVI (arch atheroma grade: r=0.46; P=0.0001) and SAVR (concomitant coronary artery bypass grafting: r=-0.33; P=0.03). Physical component score in TAVI increased after 30 days (32.1±6.6 versus 38.9±7.0; P<0.0001) and 6 months (40.4±9.3; P<0.0001); the improvement occurred later in SAVR (baseline: 34.9±10.6; 30 days: 35.9±10.2; 6 months: 42.8±11.2; P<0.001). After TAVI, there were no differences in the short form-12 health outcome scores according to the presence or size of new cerebral infarction. CONCLUSIONS: Cerebral microinfarctions are more common after TAVI compared with SAVR but seem to have no negative effect on early (30 days) or medium term (6 months) health-related quality of life. Aortic atheroma (TAVI) and concomitant coronary artery bypass grafting (SAVR) are independent risk factors for cerebral microinfarction.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Embolia Intracraneal/etiología , Anciano , Anciano de 80 o más Años , Femenino , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Calidad de Vida
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA