RESUMEN
BACKGROUND: Differential pacing technique to confirm mitral isthmus (MI) block is sometimes challenging due to destroyed tissues after extensive ablation. The purpose of this study is to set an endpoint of MI ablation using conduction time around the mitral annulus (MA). METHODS: Forty-five consecutive patients with persistent atrial fibrillation who received MI linear ablation were included. The geometry and activation times of the left atrium around the MA were collected using a multipolar catheter before ablation. During coronary sinus (CS) pacing, the time between the stimulus and the wave-front collision at the opposite side of the MA (defined as T/2) was calculated, and the doubled value was defined as the estimated perimitral conduction time (E-PMCT). The endpoint for complete MI block was when the stimulus (at distal CS) minus the maximal delayed potential (St-MDP) on the MI interval reached the E-PMCT. RESULTS: St-MDP reached E-PMCT during MI ablation in 44/45 patients. Among these 44 patients, differential pacing revealed bidirectional block in 39/44 (88.6%), whereas in 5/44 (11.4%), the differential pacing was not possible because of the loss of capture of local potentials due to extensive applications around the linear line. In one patient, the St-MDP did not reach E-PMCT (E-PMCT: 148 ms, St-MDP :130 ms) and differential pacing revealed no MI block. E-PMCT values (median 176 ms) correlated strongly with St-MDP (median 185 ms, P < 0.0001, R = 0.98). CONCLUSIONS: Although E-PMCT differs between individuals, the value is significantly correlated with the St-MDP. This technique may be useful in providing an individual endpoint of MI ablation as an alternative to differential pacing.
Asunto(s)
Potenciales de Acción , Fibrilación Atrial/cirugía , Estimulación Cardíaca Artificial , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Frecuencia Cardíaca , Válvula Mitral/cirugía , Venas Pulmonares/cirugía , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/fisiopatología , Valor Predictivo de las Pruebas , Venas Pulmonares/fisiopatología , Factores de Tiempo , Resultado del TratamientoRESUMEN
The aim of this study was to examine the mediating effects of resilience, morale, and sense of coherence on the relationship between physical activity and respondents' perceived physical/mental health and depression among community-dwelling older adults in Japan. The study included 369 participants with an average age of 74 years from Kasuishimohara District in Fukuoka Prefecture, Japan. They completed a survey that included the Resilience Scale, the Sense of Coherence Scale, the Medical Outcomes Short Form 8, the Philadelphia Geriatric Center Morale Scale, the Geriatric Depression Scale (Short Form), and a demographic questionnaire. The results of the path mediation analyses revealed that resilience and morale fully mediated the relationship between physical activity and perceived physical/mental health and depression. However, sense of coherence was not a significant mediator. Some intervention programs are suggested to maximize the effects of physical activity on one's well-being. At-risk populations who need such programs are also discussed.
Asunto(s)
Ejercicio Físico , Estado de Salud , Salud Mental , Moral , Resiliencia Psicológica , Sentido de Coherencia , Anciano , Anciano de 80 o más Años , Estudios Transversales , Femenino , Humanos , Japón , Masculino , Persona de Mediana Edad , Encuestas y CuestionariosRESUMEN
BACKGROUND: Catheter ablation (CA) of paroxysmal atrial fibrillation (PAF) is an effective treatment. However, the frequency of asymptomatic AF recurrence after CA in patients with PAF and sick sinus syndrome (SSS) is not clear. The aim of this study was to elucidate the real AF recurrence after CA in patients with PAF and a pacemaker for SSS. METHODS AND RESULTS: Fifty-one consecutive patients (mean age 66.6 ± 7.0 years, male 34) with PAF and SSS and pacemakers underwent CA. All patients were followed at 1, 3, 6, 9, and 12 months after the CA using a 12-lead ECG, Holter-ECG, and 1-month event recorder as a conventional follow-up. In addition, the pacemakers were interrogated every 12 months. During a 5-year follow-up after the final CA procedure, AF recurrences were observed in 7 patients (13.7%) with a conventional follow-up, including 1 (2.0%) asymptomatic patient. Pacemaker-interrogation revealed another 10 patients (19.6%) with asymptomatic AF recurrences. Ultimately, the conventional follow-up plus pacemaker-interrogation provided a higher incidence of AF recurrences (P = 0.009). Multiple CA procedures contributed to a significant increase in the AF-free survival rate at 5 years: 58.6% after a single CA and 86.0% after multiple CA procedures with a conventional follow-up, but which decreased to 40.6% and 60.9% with a conventional follow-up plus a pacemaker interrogation, respectively. CONCLUSIONS: One-third of PAF patients with SSS and pacemakers recurred after multiple CA sessions. However, 65% of them were asymptomatic and difficult to be identified with conventional follow-up. Pacemaker interrogation significantly increased the detection rate of AF-recurrence.
RESUMEN
INTRODUCTION: The mapping of atrial tachycardia (AT) can often be challenging and time-consuming, especially in patients with ATs that develop following cardiac surgery or are concomitant with atrial fibrillation. Recently, a new multielectrode basket catheter (MBC) has become available; we hypothesized that the MBC could be utilized to diagnose AT circuits. METHODS AND RESULTS: This study included 51 consecutive patients undergoing catheter ablation of clinically documented right-sided ATs (including 17 cases following cardiac surgery). Using a NavX system, 2 activation maps of the ATs were created, one using the new MBC (32 mm, 31 poles) and the other using a circular catheter. The time needed to complete the activation maps and the points acquired with both mapping catheters were compared. In all 64 ATs, including 34 non-cavotricuspid isthmus-dependent ATs, the AT activation maps created by both catheters were essentially identical. The number of points acquired to complete the activation maps did not differ significantly between the MBC and the circular catheter (387 [285-511] vs. 374 [269-533], P = 0.19), but the mapping time was significantly shorter using the MBC (4.0 [3.0-6.0] minutes vs. 8.0 [6.5-10.0] minutes, P < 0.0001). Inadvertent mechanical AT termination (n = 6) was observed only during mapping with the circular catheter. CONCLUSION: In patients with right-sided ATs, the use of an MBC could save mapping time.
Asunto(s)
Función del Atrio Derecho , Cateterismo Cardíaco/instrumentación , Catéteres Cardíacos , Técnicas Electrofisiológicas Cardíacas/instrumentación , Atrios Cardíacos/fisiopatología , Frecuencia Cardíaca , Taquicardia Supraventricular/diagnóstico , Potenciales de Acción , Anciano , Estimulación Cardíaca Artificial , Ablación por Catéter/instrumentación , Diseño de Equipo , Femenino , Atrios Cardíacos/cirugía , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Taquicardia Supraventricular/fisiopatología , Taquicardia Supraventricular/cirugíaRESUMEN
BACKGROUND: Paroxysmal atrial fibrillation (AF) is primarily triggered by pulmonary veins (PVs). However, non-PV AF foci may also trigger AF. METHODS: We examined 207 patients (mean age, 62 ± 11 years; 166 men) who underwent a second catheter ablation (CA) and evaluated the clinical significance of non-PV AF foci on the outcomes. RESULTS: Electrical reconnections between the PVs and left atrium (LA) were observed in 162 patients (78.3%). Non-PV AF foci were identified in 95 patients (45.9%, 60 patients with successfully ablated non-PV AF foci and 35 with unmappable non-PV AF foci). During a median follow-up period of 22.7 months, 61 patients (29.5%; 18/112 [16.1%] without non-PV AF foci vs. 20/60 [33.3%] with successfully ablated non-PV AF foci vs. 23/35 [65.7%] with unmappable non-PV AF foci, P < 0.0001) developed AF recurrence; 52 (85.2%) developed recurrence within 1 year. The presence of non-PV AF foci was a significant clinical predictor of AF recurrence after the second CA; successfully ablated non-PV AF foci increased the AF recurrence risk by 2.24 times (95% confidence interval [CI], 1.12-4.54; P = 0.02), and unmappable AF foci increased this risk by 5.58 times (95% CI, 2.73-11.63; P < 0.0001). CONCLUSION: Nearly half of the patients had non-PV AF foci at the second CA session. AF recurred after the second CA session in approximately 30%, with most recurrences happening within 1 year. The presence of non-PV AF foci significantly increased the AF recurrence risk after a second CA. When non-PV AF foci were unmappable, the AF recurrence rate was extremely high.
Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Sistema de Conducción Cardíaco/cirugía , Venas Pulmonares/cirugía , Potenciales de Acción , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Técnicas Electrofisiológicas Cardíacas , Femenino , Sistema de Conducción Cardíaco/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/fisiopatología , Recurrencia , Reoperación , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del TratamientoRESUMEN
AIMS: This study investigated whether disappearance patterns of pulmonary vein (PV) potentials (PVPs) during PV isolation (PVI) affect the outcome of catheter ablation (CA) in patients with paroxysmal atrial fibrillation (PAF). METHODS AND RESULTS: Extensive PVI was performed in 1149 PAF patients (age, 61 ± 10 years). Clinical and demographic characteristics, ablation data, and follow-up outcomes were prospectively collected. During an initial CA, simultaneous disappearance of superior and inferior PVPs in both right and left PVs was observed in 464 (40.4%) patients (Group S). Atrial fibrillation-recurrence free rates at 1, 3, and 5 years after the initial CA in Group S were 78.9, 71.9, and 68.1%, respectively, which were higher than those in Group Non-S (P = 0.004). However, those were similar after the final CA between both groups. The incidence of PV-left atrium (LA) electrical reconnection was significantly lower in Group S than in Group Non-S in the second (Group S, 65.6% vs. Group Non-S, 82.1%; P = 0.004) and third (Group S, 8.3% vs. Group Non-S, 47.6%; P = 0.03) CAs. Furthermore, the reconnections more frequently occurred on the side of PVs where simultaneous PVP elimination had not been achieved at the initial CA. Simultaneous disappearance of superior and inferior PVPs in both right and left PVs independently reduced the risk of AF recurrence after the initial CA by 26%. CONCLUSIONS: The simultaneous disappearance of superior and inferior PVPs in both right and left PVs is associated with less frequent PV-left atrium reconnection and may yield a better clinical outcome after the initial CA.
Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Sistema de Conducción Cardíaco/cirugía , Venas Pulmonares/cirugía , Potenciales de Acción , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Supervivencia sin Enfermedad , Técnicas Electrofisiológicas Cardíacas , Femenino , Sistema de Conducción Cardíaco/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/fisiopatología , Recurrencia , Estudios Retrospectivos , Factores de Tiempo , Resultado del TratamientoRESUMEN
AIM: Atrial fibrillation (AF) ablation can result in oesophageal injuries that lead to atrio-oesophageal fistulae, a life-threatening complication. This study aimed to evaluate whether oesophageal cooling could prevent oesophageal lesions complicating AF ablation. METHODS AND RESULTS: We randomly assigned 100 patients with drug-resistant AF to an oesophageal cooling group or a control group. In the oesophageal cooling group, we injected 5 mL of ice water into the oesophagus prior to radiofrequency (RF) energy delivery adjacent to the oesophagus. If the oesophageal temperature reached 42°C, the RF energy delivery was stopped, and the ice water injection was repeated. In the control group, oesophageal cooling was not applied. Oesophageal endoscopy was performed 1 day after the catheter ablation, and lesions were qualitatively assessed as mild, moderate, or severe. The numbers of ablation sites with an oesophageal temperature of >42°C were 1.7 ± 1.4 and 2.6 ± 1.7 in the oesophageal cooling group and the control group, respectively (P = 0.04), and the maximal oesophageal temperature at those sites was 43.0 ± 0.6 and 44.7 ± 0.9°C (P < 0.0001). Oesophageal lesions occurred almost equally between the oesophageal cooling group [10 of 50 patients (20%)] and the control group [11 of 50 patients (22%)]. However, the severity of the oesophageal lesions was slightly milder in the oesophageal cooling group (three moderate, seven mild) than in the control group (three severe, one moderate, seven mild). CONCLUSION: Oesophageal cooling may alleviate the severity of oesophageal lesions but does not reduce the incidence of this complication under the specific protocol evaluated here.
Asunto(s)
Fibrilación Atrial/cirugía , Fibrilación Atrial/terapia , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Enfermedades del Esófago/etiología , Enfermedades del Esófago/prevención & control , Hipotermia Inducida/métodos , Fibrilación Atrial/complicaciones , Terapia Combinada/métodos , Femenino , Humanos , Hielo , Incidencia , Masculino , Persona de Mediana Edad , Medición de Riesgo , Irrigación Terapéutica/métodos , Resultado del TratamientoRESUMEN
BACKGROUND: The aim of this study was to investigate the incidence and predictors (which have not previously been fully elucidated) of late-phase thromboembolism (TE) after catheter ablation (CA) for paroxysmal atrial fibrillation (AF). METHODS AND RESULTS: We studied 1,156 consecutive patients (61±10 years; 891 men; CHADS2score, 0.8±1.0) after CA for symptomatic paroxysmal AF and examined the details of late-phase TE. During a follow-up of 49.5±21.9 months (median, 47 months; range, 6-113 months) after CA, 9 patients (0.78%) developed late-phase TE, all of which were ischemic stroke. Of these, 5 patients with AF recurrence experienced cardioembolism; the AF was asymptomatic at recurrence. The remaining 4 without AF recurrence experienced cardioembolism (n=1), small-vessel occlusion (n=1), large-artery atherosclerosis (n=1), and stroke of other determined etiology (n=1). On Kaplan-Meier analysis patients with structural heart disease (P=0.003), AF recurrence after the final CA (P=0.01), prior stroke (P=0.002), CHADS2score ≥2 (P=0.0002), left ventricular ejection fraction <50% (P<0.0001), and spontaneous echo contrast on transesophageal echocardiogram (P=0.0004) had a significantly higher risk of late-phase TE. Multivariate analysis indicated that CHADS2score ≥2 (HR, 4.49; 95% CI: 1.08-22.56; P=0.04) independently predicted late-phase TE. CONCLUSIONS: The incidence of TE was low after CA for paroxysmal AF, but CHADS2score ≥2 independently increased the risk of late-phase TE.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter/efectos adversos , Complicaciones Posoperatorias , Tromboembolia , Anciano , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/mortalidad , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Supervivencia sin Enfermedad , Ecocardiografía Transesofágica , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/fisiopatología , Factores de Riesgo , Volumen Sistólico , Tasa de Supervivencia , Tromboembolia/diagnóstico por imagen , Tromboembolia/etiología , Tromboembolia/mortalidad , Tromboembolia/fisiopatología , Factores de TiempoRESUMEN
BACKGROUND: Bidirectional mitral isthmus (MI) block is conventionally verified by differential pacing from the coronary sinus (CS) and its sequence change. This study aimed to evaluate the ability of differential pacing from the vein of Marshall (VOM) to detect epicardial MI connections. METHODS: Radiofrequency and VOM ethanol MI ablation were performed with a VOM electrode catheter inserted to the septal side of the ablation line. MI block was verified using conventional CS pacing. To perform differential VOM pacing analysis, initial pacing was delivered from a distal VOM bipole closer to the block line, and then from a proximal VOM bipole. The intervals from pacing stimulus during different VOM pacing sites to the electrogram recorded through the CS catheter on the opposite side of the line were compared. When the interval during distal VOM pacing was longer than that during proximal VOM pacing, it indicated a VOM connection block; however, if the former interval was shorter, the connection through the VOM was considered persistent. RESULTS: Overall, 50 patients were evaluated. According to CS pacing, MI ablation was incomplete in 9 patients, in whom the analysis indicated persistent VOM connection. Among 41 patients with complete MI block, confirmed by CS finding, in 30 (73%) patients, the interval during distal VOM pacing was longer than that during proximal VOM pacing by 11±5 ms. However, in 11 patients (27%) the former interval was revealed to be shorter than the latter by 16±8 ms, indicating residual VOM connection. Conduction time across the line was significantly shorter in 11 patients than in the other 30 (166±21 versus 197±36 ms; P<0.01). Ten successful reevaluated analyses after VOM ethanol and further radiofrequency ablation of the connection indicated VOM block achievement. CONCLUSIONS: Differential VOM pacing maneuver reflects the VOM conduction status. This maneuver can uncover residual epicardial connections that are missing with CS pacing.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Venas/cirugía , Frecuencia Cardíaca , EtanolRESUMEN
BACKGROUND: Kidney function is a known predictor of cardiovascular morbidity and mortality. Although patients with atrial fibrillation (AF) often have kidney dysfunction, less is known about the association between AF and kidney function. We sought to assess changes in kidney function after catheter ablation of AF. METHODS AND RESULTS: Patients who underwent catheter ablation of AF were recruited for the present prospective study. Estimated glomerular filtration rate (eGFR) was evaluated before and 1 year after the ablation. Three hundred eighty-six patients (paroxysmal AF, 135; persistent AF, 106; longstanding persistent AF, 145) were studied. Their baseline eGFR was 68 ± 14 mL · min(-1) · 1.73 m(-2). Sixty-six percent and 26% of patients had eGFR of 60 to 89 and 30 to 59 mL · min(-1) · 1.73 m(-2), respectively. Overall, 278 patients (72%) were arrhythmia free over a 1-year follow-up. In patients free from arrhythmia, eGFR increased 3 months later and was maintained until 1 year, whereas in patients with recurrences, eGFR had decreased over 1 year. Changes in eGFR over 1 year in patients free from arrhythmia differed significantly compared with those with recurrences (3 ± 8 versus -2 ± 8 mL · min(-1) · 1.73 m(-2); P<0.0001). In all quartiles of baseline eGFR, changes in eGFR over 1 year after the ablation were greater in patients free from arrhythmia compared with those with recurrences. CONCLUSION: Elimination of AF by catheter ablation was associated with improvement of kidney function over a 1-year follow-up in patients with mild to moderate kidney dysfunction.
Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Tasa de Filtración Glomerular/fisiología , Riñón/fisiopatología , Anciano , Fibrilación Atrial/complicaciones , Fibrilación Atrial/fisiopatología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Insuficiencia Renal/epidemiología , Factores de Riesgo , Nodo Sinoatrial/fisiopatología , Resultado del TratamientoRESUMEN
PURPOSE: The LUMIPOINT™ software module was developed to aid the physician in determining the mechanism of individual atrial tachycardias (ATs). The purpose of this study was to assess the clinical utility of the SKYLINE™ histogram that is a part of LUMIPOINT™. METHODS: This study included consecutive patients with iatrogenic sustained AT who underwent catheter ablation using conventional mapping (RHYTHMIA™). SKYLINE™ patterns were analyzed offline and classified into two types: (1) focal type (type-F) exhibiting a low-amplitude (relative activating surface area < 10%) plateau period and (2) reentrant type (type-R) showing no plateau period. How well the two patterns distinguished between focal and macroreentrant ATs as determined by conventional mapping was evaluated. RESULTS: We studied 101 iatrogenic ATs in 91 patients (female: 24, mean age: 67.3 ± 9.1 years). Activation mapping revealed 79 (78.2%) macroreentrant, 6 (5.9%) localized reentrant, and 16 (15.8%) focal ATs. Among the 72 type-R ATs, the mechanism was truly a macroreentry in 70 ATs. However, one focal AT and one localized reentrant AT displayed a type-R pattern (pseudo-reentry pattern). In the 29 type-F ATs, nine macroreentrant ATs were recognized (pseudo-focal pattern). Using SKYLINE™ type-R to differentiate macroreentrant AT from AT with centrifugal activation (focal or localized reentry), the sensitivity and specificity were 88.6% and 90.9%, respectively. Even when the SKYLINE™ type did not match the mapping-based AT mechanism, all discrepancies were electrophysiologically explicable using the SKYLINE™ histograms. CONCLUSIONS: SKYLINE™ histograms are a useful tool for the intuitive diagnosis of AT mechanisms.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Taquicardia Atrial Ectópica , Taquicardia Supraventricular , Anciano , Fibrilación Atrial/cirugía , Femenino , Humanos , Enfermedad Iatrogénica , Persona de Mediana Edad , Taquicardia Atrial Ectópica/cirugía , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirugía , Resultado del TratamientoRESUMEN
BACKGROUND: The vein of Marshall (VOM), which is surrounded by the Marshall bundle (MB), behaves as an epicardial connection bypassing the mitral isthmus. The influence of radiofrequency ablation and VOM ethanol infusion (VOM-EI) on epicardial MB conduction remains unclear. OBJECTIVE: The purpose of this study was to evaluate MB conduction status during mitral isthmus ablation. METHODS: Of 57 consecutive patients undergoing mitral isthmus ablation, 50 with electrode catheter cannulation into the VOM were analyzed. MB conduction was investigated by evaluating electrograms inside the VOM. Endocardial ablation was initially performed, followed by ablation inside the coronary sinus (CS), if required. Selective VOM-EI was performed if the MB potentials still exhibited early activation after radiofrequency ablation, suggesting the presence of MB connection bridging the mitral isthmus. RESULTS: VOM electrograms composed of near-field MB and far-field left atrial potentials were recorded in all patients. Solely with endocardial ablation, 33 patients (66%) achieved entire mitral isthmus block, and 43 patients (86%) achieved an epicardial MB conduction block. MB potentials exhibited early activation in the remaining 7 (14%), even after requiring CS ablation. VOM-EI then was performed. Elimination of MB potentials was verified by electrode catheter reinsertion after VOM-EI. Mitral isthmus conduction was successfully blocked during VOM-EI in 4 patients and during additional radiofrequency ablation in the remaining 3. All patients finally achieved entire mitral isthmus block. CONCLUSION: MB is effectively ablated by radiofrequency ablation. Continuous evaluation of MB conduction can reveal epicardial conduction and ablation effect. A residual MB epicardial connection is relatively rare but can be ablated by VOM-EI.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Etanol/farmacología , Atrios Cardíacos , Frecuencia Cardíaca , HumanosRESUMEN
The tails of core histones (H2A, H2B, H3 and H4) are critical for the regulation of chromatin dynamics. Each core histone tail is specifically recognized by various tail binding proteins. Here we screened for budding yeast histone H4-tail binding proteins in a protein differential display approach by two-dimensional gel electrophoresis (2DGE). To obtain highly enriched chromatin proteins, we used a Mg2+-dependent chromatin oligomerization technique. The Mg2+-dependent oligomerized chromatin from H4-tail deleted cells was compared with that from wild-type cells. We used mass spectrometry to identify 22 candidate proteins whose amounts were reduced in the oligomerized chromatin from the H4-tail deleted cells. A Saccharomyces Genome Database search revealed 10 protein complexes, each of which contained more than two candidate proteins. Interestingly, 7 out of the 10 complexes have the potential to associate with the H4-tail. We obtained in vivo evidence, by a chromatin immunoprecipitation assay, that one of the candidate proteins, Pwp1p, associates with the 25S ribosomal DNA (rDNA) chromatin in an H4-tail-dependent manner. We propose that the complex containing Pwp1p regulates the transcription of rDNA. Our results demonstrate that the protein differential display approach by 2DGE, using a histone-tail mutant, is a powerful method to identify histone-tail binding proteins.
Asunto(s)
Cromatina/metabolismo , Proteínas Cromosómicas no Histona/metabolismo , Histonas/metabolismo , ARN Ribosómico/genética , Proteínas de Saccharomyces cerevisiae/metabolismo , Saccharomyces cerevisiae/genética , Cromatina/aislamiento & purificación , Proteínas Cromosómicas no Histona/análisis , Proteínas Cromosómicas no Histona/aislamiento & purificación , Electroforesis en Gel Bidimensional , Histonas/genética , Magnesio/química , Nucleasa Microcócica , Estructura Terciaria de Proteína , Saccharomyces cerevisiae/metabolismo , Proteínas de Saccharomyces cerevisiae/análisis , Proteínas de Saccharomyces cerevisiae/aislamiento & purificación , Eliminación de SecuenciaRESUMEN
PURPOSE: Achieving complete mitral isthmus (MI) conduction block for atrial fibrillation (AF) ablation remains challenging. We hypothesized that transseptal puncture (TSP) at the anteroinferior aspect of the atrial septum (anteroinferior TSP) could shorten the distance to the MI and improve catheter contact and stability, enabling complete MI block. This study investigated the efficacy of anteroinferior TSP for MI ablation in AF patients. METHODS: Three hundred and twenty consecutive patients (mean age: 62 ± 9 years, 84 % male) with persistent AF undergoing AF ablation, including MI ablation, were enrolled. MI ablation was performed through the conventional (posterior) TSP site (group C, n = 170) or the anteroinferior TSP site (group A, n = 150). RESULTS: Left atrial diameter (LAD) enlargement was greater in group A than in group C (45.8 ± 5.3 mm vs. 44.1 ± 5.0 mm, p = 0.002). Complete MI block at the initial session was significantly higher in group A than in group C (141/150 [94 %] vs. 144/170 [85 %], p = 0.011). At the repeat session for AF recurrence, the rate of persistent complete MI block was significantly higher in group A than in group C (36/48 [75 %] vs. 28/67 [42 %], p < 0.001). LAD (p = 0.011) and left ventricular diastolic dimension (p = 0.037) were significant predictors of failed MI block, while anteroinferior TSP was significantly associated with successful MI block (p < 0.001). CONCLUSION: Anteroinferior TSP could improve the initial success rate and long-term persistence of complete MI block for AF ablation.
Asunto(s)
Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Ablación por Catéter/estadística & datos numéricos , Sistema de Conducción Cardíaco/cirugía , Punciones/estadística & datos numéricos , Terapia Combinada/métodos , Supervivencia sin Enfermedad , Femenino , Tabiques Cardíacos/cirugía , Humanos , Japón/epidemiología , Masculino , Persona de Mediana Edad , Prevalencia , Factores de Riesgo , Resultado del TratamientoRESUMEN
BACKGROUND: The present study aimed to elucidate the safety and effectiveness of a noble and unique airway management technique in which a pediatric intubation tube is used in adult patients with atrial fibrillation (AF) undergoing catheter ablation (CA) under continuous deep sedation. METHODS: In total, 246 consecutive patients with AF (mean age, 65±10 years; 60 women) underwent CA under dexmedetomidine-based continuous deep sedation. A 4-mm pediatric intubation tube guided by a 10-French intratracheal suction tube was inserted smoothly, and the tip of the tube was located at the base of the epiglottis. The maximum shifting distance of the heart (MSDH) was measured with the 3D mapping system (Ensite NavX system) before and after inserting the pediatric intubation tube. RESULTS: At baseline, the MSDH of patients under continuous deep sedation was 23±14 mm. The pediatric intubation tube reduced the MSDH to 13±6 mm (mean reduction from baseline, 38.4±21.7%; P<0.0001). In contrast, oxygen saturation was significantly increased from 89±8% to 95±3% (P<0.0001). The mean distance between the nostril and base of the epiglottis was 16.6±0.5 mm. Major periprocedural complications occurred in 9 (3.6%) patients including 3 (1.2%) cardiac tamponade and 6 (2.4%) phrenic nerve injury cases. Larger MSDH (odds ratio, 1.13; 95% confidence interval, 1.04-1.25; P=0.007) was a significant predictor of major periprocedural complications. No major airway complications occurred, except in 3 patients (1.2%) who had minor nasal bleeding. CONCLUSION: This unique airway management technique using a pediatric intubation tube for CA procedures performed in adult patients with AF under continuous deep sedation was easy, safe, and effective.
RESUMEN
BACKGROUND: We aimed to determine whether differing foci in paroxysmal atrial fibrillation (PAF) affected the long-term outcome of catheter ablation (CA). METHODS: A total of 865 consecutive PAF patients (age, 61±10years; 670 male) undergoing initial AF ablation were included. After pulmonary vein (PV) isolation, superior vena cava (SVC) isolation was performed for SVC foci; other non-PV foci were focally ablated. Long-term outcomes were compared among patients with SVC foci (Group SVC), other non-PV foci (Group Non-PV), and those without these foci (Group PV). RESULTS: Groups PV, SVC, and Non-PV contained 740 (85.8%), 57 (6.6%), and 68 (7.6%) patients, respectively. Structural heart disease (P=0.01) and duration of AF history (P=0.04) were significantly associated with Group Non-PV, and female sex (P=0.0002) was significantly associated with Group SVC. AF recurrence-free rates at 5years in Group PV, SVC, and Non-PV were 62.0%, 66.3%, and 49.3%, respectively (P=0.03), after the initial CA, and 84.7%, 83.9%, and 77.0%, respectively (P=0.02), after the final CA. The duration of AF history (HR, 1.04, P<0.0001) and left atrial dimension (HR, 1.37 per 10mm increase, P=0.0003) were significant predictors of AF recurrence after the initial CA. Although Group Non-PV was weakly associated (HR 1.38, P=0.08) with AF recurrence, Group SVC was not associated with AF recurrence. CONCLUSIONS: Long-term outcome of CA of PAF was significantly worse in patients with non-PV foci other than SVC foci. These foci may affect the outcome not independently but as an aspect of atrial remodeling.
Asunto(s)
Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter , Venas Pulmonares , Vena Cava Superior , Anciano , Fibrilación Atrial/mortalidad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Factores de Tiempo , Resultado del TratamientoRESUMEN
Capecitabine is an oral fluoropyrimidine which can prolong QT interval. However, there have been no reports that capecitabine induced ventricular fibrillation (VF) due to secondary QT prolongation in patients with no structural heart disease. A 39-year-old woman developed VF during the chemotherapy of capecitabine for colon cancer. At the administration, corrected QT interval (QTc) was prolonged to 559 ms despite no evidence of organic heart disease. Discontinuation of capecitabline normalized the QTc (414 ms). During the follow-up of eight years, neither the QTc prolongation nor the recurrent VF has been detected. We report the rare case of capecitabine-related VF without any organic heart disease.
RESUMEN
BACKGROUND: Although several studies have reported an association between atrial fibrillation (AF) and alcohol, the impact of alcohol consumption on the outcome after catheter ablation (CA) for AF has not been discussed. We aimed to elucidate the effect of alcohol consumption on the outcome of CA for paroxysmal AF. METHODS AND RESULTS: We examined 1361 consecutive patients with paroxysmal AF (mean age, 61±11 years, 334 women) who underwent CA, including 623 (45.8%) patients who consumed alcohol. The clinical characteristics and outcomes of CA were compared between patients who did and did not consume alcohol. No significant differences were seen in the left atrial size, duration of AF history, and incidence of nonpulmonary vein foci between 2 groups (P=NS). Although the AF recurrence-free rate after the initial CA was higher in patients who did not consume alcohol (261/623 [41.9%] versus 252/738 [34.1%]; mean follow-up, 44.4±30.7 months; P=0.003), the outcome after the final CA was similar between 2 groups (patients who consumed alcohol: 111/628 [17.7%] versus patients who did not consume alcohol: 138/738 [18.7%]; mean follow-up, 53.1±25.8 months; P=0.67). The frequency (hazard ratio 1.07 per 1 day/week increase, CI 1.00-1.15, P=0.04) of alcohol consumption was significantly associated with AF recurrence after CA. CONCLUSIONS: The frequency of alcohol consumption may be associated with AF recurrence after the initial CA for paroxysmal AF, but it may not affect the outcome after the final CA.
Asunto(s)
Consumo de Bebidas Alcohólicas/epidemiología , Fibrilación Atrial/cirugía , Ablación por Catéter , Anciano , Fibrilación Atrial/epidemiología , Técnicas Electrofisiológicas Cardíacas , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Modelos de Riesgos Proporcionales , Recurrencia , Resultado del TratamientoRESUMEN
BACKGROUND: Mitral regurgitation (MR) is generally classified as either primary (organic) or secondary (functional). Although patients with atrial fibrillation (AF) often exhibit MR, the relation between the etiology of MR and the outcome of catheter ablation (CA) remains unknown. We conducted this study in order to elucidate this association. METHODS: Among 1330 consecutive paroxysmal AF patients who underwent initial catheter ablation in our institution, 92 patients (62 men, mean age 65 ± 7 years) who had moderate or severe MR were included in this study; 46 were classified to have primary and the remaining 46 to have secondary MR by preoperative echocardiography. These patients were prospectively monitored after the CA. RESULTS: During a mean follow-up period of 27.9 ± 28.8 months, AF recurred in 26/46 (56.6 %) of primary MR patients and in 15/46 (32.6 %) of those with secondary MR (P < 0.02). Although univariate analysis found that diabetes, left atrial volume indexed by body surface area (LAVI), and primary MR were significantly associated with AF recurrence, primary MR (hazard ratio (HR), 2.47; 95 % confidence interval (CI), 1.30-4.88; P = 0.006) and LAVI (HR, 1.03/1 mL/m(2) increase; 95 % CI, 1.00-1.06; P = 0.03) remained significant predictors on multivariate analysis. The AF recurrence-free rate was lower in patients with primary MR after both the initial and final CA. CONCLUSION: In patients with paroxysmal AF and moderate or severe MR, primary MR may increase the risk of AF recurrence after the initial and final CA.