Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Opt Express ; 30(6): 8734-8741, 2022 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-35299319

RESUMEN

We demonstrated sub-10 fs pulse generation by the post-compression of a 100 TW Ti:Sapphire laser to enhance the peak-power. In the post-compression, the laser spectrum was widely broadened by self-phase modulation in thin fused silica plate(s), and the induced spectral phase was compensated with a set of chirped mirrors. A spatial filter stage, consisting of two cylindrical lenses and a spherical lens, was employed to reduce the intensity modulation existing in the laser beam, which effectively suppressed intensity spikes induced by self-focusing. The laser beam was post-compressed from 23 fs to 9.7 fs after propagating through a 1.5 mm fused silica plate, resulting in the peak-power enhancement by a factor of 2.1.

2.
Opt Express ; 30(15): 26212-26219, 2022 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-36236816

RESUMEN

We analyzed and corrected the wavefront distortion induced during the post-compression of a 100-TW Ti:Sapphire laser and achieved the intensity enhancement. In the post-compression, the spectral broadening of the laser was obtained by propagating through three 0.5 mm-thick fused silica plates and the laser pulse duration was post-compressed from 24 fs to 11 fs using a set of chirped mirrors. We measured the wavefront aberrations due to the intensity-dependent nonlinear process during the post-compression of femtosecond high-power laser pulses. By compensating for the wavefront aberrations with an adaptive optics system, the Strehl ratio of the post-compressed beam was improved from 0.37 to 0.52 and the focused intensity of the post-compressed beam could be enhanced by a factor of 1.5, while the enhancement without the wavefront correction was only a factor of 1.1 in spite of the peak-power enhancement by a factor of 1.8.

3.
Phys Rev Lett ; 127(17): 175003, 2021 Oct 22.
Artículo en Inglés | MEDLINE | ID: mdl-34739265

RESUMEN

Ultrafast optical excitation of matter leads to highly excited states that are far from equilibrium. In this study, femtosecond x-ray absorption spectroscopy was used to visualize the ultrafast dynamics in photoexcited warm dense Cu. The rich dynamical features related to d vacancies are observed on femtosecond timescales. Despite the success in explaining x-ray absorption data in the picosecond regime, the new femtosecond data are poorly understood through the traditional two-temperature model based on the fast thermalization concept and the static electronic structure for high-temperature metals. An improved understanding can be achieved by including the recombination dynamics of nonthermal electrons and changes in the screening of the excited d block. The population balance between the 4sp and 3d bands is mainly determined by the recombination rate of nonthermal electrons, and the underpopulated 3d block is initially strongly downshifted and recovered in several hundreds of femtoseconds.

4.
Opt Express ; 28(26): 38842-38856, 2020 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-33379444

RESUMEN

Angular dispersion observed in a nanosecond optical parametric chirped-pulse amplification (ns-OPCPA) amplifier adopted in the frontend of a multi-PW laser was analyzed. The theory on the angular dispersion, extended by including the wavefront rotation and the pulse front tilt of a strongly chirped laser pulse, revealed that the wavefront rotation is a major contributor to the angular dispersion, as compared to the pulse front tilt, in a ns-OPCPA amplifier. It was also shown that the wavefront rotation could be introduced by the phase mismatch and the noncollinear propagation angle in the noncollinear ns-OPCPA amplifier. The theoretical prediction was experimentally verified by measuring the angular dispersion of the ns-OPCPA frontend installed in the 20-fs, 4-PW Ti:Sapphire laser. We emphasize the importance of the proper characterization and control of the angular dispersion in the ns-OPCPA amplifier since the focus intensity of an ultrahigh power laser could be significantly reduced due to the spatiotemporal effect even for small induced angular dispersion.

5.
Opt Lett ; 45(23): 6342-6345, 2020 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-33258807

RESUMEN

We present a highly efficient double plasma mirror (DPM) that provides ultrahigh-contrast multi-petawatt (PW) laser pulses with a temporal contrast ratio reaching 1017 up to 160 ps and 1012 up to 2 ps before the main pulse. The high reflectivity of 70%, along with the high-contrast enhancement factor of 700,000, was achieved from the DPM installed after the final stage of a 4 PW Ti:sapphire laser. The 4 PW laser was equipped with cross-polarized wave generation and optical parametric chirped-pulse amplification stages for initial high-contrast operation. The DPM operation was undertaken with conditions that did not modify the spatiotemporal profiles of incident multi-PW laser pulses. This highly efficient DPM with the high-contrast enhancement promises the utilization of multiple PMs as a practical rear end for upcoming tens of petawatt lasers to achieve ultrahigh temporal contrast.

6.
Opt Express ; 27(15): 20412-20420, 2019 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-31510135

RESUMEN

The generation of ultrahigh intensity laser pulses was investigated by tightly focusing a wavefront-corrected multi-petawatt Ti:sapphire laser. For the wavefront correction of the PW laser, two stages of deformable mirrors were employed. The multi-PW laser beam was tightly focused by an f/1.6 off-axis parabolic mirror and the focal spot profile was measured. After the wavefront correction, the Strehl ratio was about 0.4, and the spot size in full width at half maximum was 1.5×1.8 µm2, close to the diffraction-limited value. The measured peak intensity was 5.5×1022 W/cm2, achieving the highest laser intensity ever reached.

7.
Phys Rev Lett ; 122(1): 014803, 2019 Jan 11.
Artículo en Inglés | MEDLINE | ID: mdl-31012707

RESUMEN

We report the experimental generation of highly energetic carbon ions up to 48 MeV per nucleon by shooting double-layer targets composed of well-controlled slightly underdense plasma and ultrathin foils with ultraintense femtosecond laser pulses. Particle-in-cell simulations reveal that carbon ions are ejected from the ultrathin foils due to radiation pressure and then accelerated in an enhanced sheath field established by the superponderomotive electron flow. Such a cascaded acceleration is especially suited for heavy ion acceleration with femtosecond laser pulses. The breakthrough of heavy ion energy up to many tens of MeV/u at a high repetition rate would be able to trigger significant advances in nuclear physics, high energy density physics, and medical physics.

8.
Opt Express ; 26(19): 24775-24783, 2018 Sep 17.
Artículo en Inglés | MEDLINE | ID: mdl-30469589

RESUMEN

We developed an OPCPA preamplifier with an actively shaped output spectrum to obtain a sub-20-fs-duration pulse for a 4-PW laser. The active spectral shaping was facilitated by controlling the temporal profile of a pump pulse in the OPCPA preamplifier. By optimizing the output spectrum of the OPCPA to compensate for the gain-depletion effect in the 4-PW laser, a final laser pulse with a broad spectrum of 101-nm in width (FWHM), resulting in a short pulse duration of 17 fs, was achieved.

9.
Opt Lett ; 42(11): 2058-2061, 2017 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-28569844

RESUMEN

We demonstrated the generation of 4.2 PW laser pulses at 0.1 Hz from a chirped-pulse amplification Ti:sapphire laser. The cross-polarized wave generation and the optical parametric chirped-pulse amplification stages were installed for the prevention of the gain narrowing and for the compensation of the spectral narrowing in the amplifiers, obtaining the spectral width of amplified laser pulses of 84 nm (FWHM), and enhancing the temporal contrast. The amplified laser pulses of 112 J after the final booster amplifier were compressed to the pulses with 83 J at 19.4 fs with a shot-to-shot energy stability of 1.5% (RMS). This 4.2 PW laser will be a workhorse for exploring high field science.

10.
Phys Rev Lett ; 119(7): 075002, 2017 Aug 18.
Artículo en Inglés | MEDLINE | ID: mdl-28949680

RESUMEN

A nonlinear absorber in which the excited state absorption is larger than the ground state can undergo a process called reverse saturable absorption. It is a well-known phenomenon in laser physics in the optical regime, but is more difficult to generate in the x-ray regime, where fast nonradiative core electron transitions typically dominate the population kinetics during light matter interactions. Here, we report the first observation of decreasing x-ray transmission in a solid target pumped by intense x-ray free electron laser pulses. The measurement has been made below the K-absorption edge of aluminum, and the x-ray intensity ranges are 10^{16} -10^{17} W/cm^{2}. It has been confirmed by collisional radiative population kinetic calculations, underscoring the fast spectral modulation of the x-ray pulses and charge states relevant to the absorption and transmission of x-ray photons. The processes shown through detailed simulations are consistent with reverse saturable absorption, which would be the first observation of this phenomena in the x-ray regime. These light matter interactions provide a unique opportunity to investigate optical transport properties in the extreme state of matters, as well as affording the potential to regulate ultrafast x-ray free-electron laser pulses.

11.
Phys Rev Lett ; 114(15): 153901, 2015 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-25933315

RESUMEN

High-harmonic radiation emitted from molecules in a strong laser field contains information on molecular structure and dynamics. When multiple molecular orbitals participate in high-harmonic generation, resolving the contribution of each orbital is crucial for understanding molecular dynamics and for extending high-harmonic spectroscopy to more complicated molecules. We show that two-dimensional high-harmonic spectroscopy can resolve high-harmonic radiation emitted from the two highest-occupied molecular orbitals, HOMO and HOMO-1, of aligned molecules. By the application of an orthogonally polarized two-color laser field that consists of the fundamental and its second-harmonic fields to aligned CO2 molecules, the characteristics attributed to the two orbitals are found to be separately imprinted in odd and even harmonics. Two-dimensional high-harmonic spectroscopy may open a new route to investigate ultrafast molecular dynamics during chemical processes.

12.
Opt Express ; 22(3): 3684-90, 2014 Feb 10.
Artículo en Inglés | MEDLINE | ID: mdl-24663660

RESUMEN

Carrier-envelope-phase (CEP)-dependent modulation was measured in above-threshold ionization of xenon driven with 30-fs laser pulses. We showed the dependence from the asymmetry map obtained using a velocity map imaging spectrometer, up to 17 eV in photoelectron energy. The dependence appeared to be linear with a slope of one photon energy increase per CEP change of 2π and did not rely on the sign or the amount of laser chirp. Our results indicated the existence of the quantum interference between different multiphoton ionization paths.

13.
Opt Lett ; 38(8): 1253-5, 2013 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-23595449

RESUMEN

We have demonstrated ultrafast direct soft x-ray microscopy imaging. Microscopy images were acquired using an objective zone plate and a single strong high harmonic burst generated from He in a two-color laser field. This zone-plate-based microscopy system delivered real-space images directly without any data processing. The spatial resolution of the microscope was estimated to be about 140 nm from the image of nanoscale grating patterns.

14.
Sci Rep ; 13(1): 310, 2023 Jan 06.
Artículo en Inglés | MEDLINE | ID: mdl-36609530

RESUMEN

The characterization of an electron-positron beam generated from the interaction of a multi-GeV electron beam with a lead plate is performed using GEANT4 simulations. The dependence of the positron beam size on driver electron beam energy and lead converter thickness is investigated in detail. A pancake-like positron beam structure is generated with a monoenergetic multi-GeV driver electron beam, with the results indicating that a 5 GeV driver electron beam with 1 nC charge can generate a positron beam with a density of 1015-1016 cm-3 at one radiation length of lead. In addition, we find that electron-positron beams generated using above-GeV electron beams have neutralities greater than 0.3 at one radiation length of lead, whereas neutralities of 0.2 are observed when using a 200 MeV electron beam. The possibility of observing plasma instabilities in experiments is also examined by comparing the plasma skin depth with the electron-positron beam size. A quasi-neutral electron-positron plasma can be produced in the interaction between a 1 nC, 5 GeV electron beam and lead with a thickness of five radiation lengths. Our findings will aid in analyzing and interpreting laser-produced electron-positron plasma for laboratory astrophysics research.

15.
Nat Commun ; 14(1): 2328, 2023 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-37087465

RESUMEN

High-harmonic radiation can be generated when an ultra-intense laser beam is reflected from an over-dense plasma, known as a plasma mirror. It is considered a promising technique for generating intense attosecond pulses in the extreme ultraviolet and X-ray wavelength ranges. However, a solid target used for the formation of the over-dense plasma is completely damaged by the interaction. Thus, it is challenging to use a solid target for applications such as time-resolved studies and attosecond streaking experiments that require a large amount of data. Here we demonstrate that high-harmonic radiation can be continuously generated from a liquid plasma mirror in both the coherent wake emission and relativistic oscillating mirror regimes. These results will pave the way for the development of bright, stable, and high-repetition-rate attosecond light sources, which can greatly benefit the study of ultrafast laser-matter interactions.

16.
Phys Rev Lett ; 108(9): 093001, 2012 Mar 02.
Artículo en Inglés | MEDLINE | ID: mdl-22463629

RESUMEN

Ultrafast atomic processes, such as excitation and ionization occurring on the femtosecond or shorter time scale, were explored by employing attosecond high-harmonic pulses. With the absorption of a suitable high-harmonic photon a He atom was ionized, or resonantly excited with further ionization by absorbing a number of infrared photons. The electron wave packets liberated by the two processes generated an interference containing the information on ultrafast atomic dynamics. The attosecond electron wave packet, including the phase, from the ground state was reconstructed first and, subsequently, that from the 1s3p state was retrieved by applying the holographic technique to the photoelectron spectra comprising the interference between the two ionization paths. The reconstructed electron wave packet revealed details of the ultrafast photoionization dynamics, such as the instantaneous two-photon ionization rate.

17.
Rev Sci Instrum ; 93(11): 113001, 2022 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-36461441

RESUMEN

In all-optical Compton scattering driven by a multi-petawatt laser, it is critical to have accurate spatiotemporal synchronization between the ultrarelativistic electron bunch and the ultrahigh-intensity laser beam. Such a synchronization was realized by using two complementary optical setups. The first setup, used for the initial synchronization, recorded the spatial interferogram between the two femtosecond lasers used for a GeV electron beam production and an ultrahigh scattering laser beam. The second one, consisting of spatial and spectral interferometers, measured the time delay between the two laser beams in the range of 0-200 fs in real time. These monitoring systems played an essential role in conducting Compton scattering experiments.

18.
Sci Rep ; 12(1): 11128, 2022 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-35778463

RESUMEN

A localized nanoparticle insertion scheme is developed to decouple electron injection from laser evolution in laser wakefield acceleration. Here we report the experimental realization of a controllable electron injection by the nanoparticle insertion method into a plasma medium, where the injection position is localized within the short range of 100 µm. Nanoparticles were generated by the laser ablation process of a copper blade target using a 3-ns 532-nm laser pulse with fluence above 100 J/cm2. The produced electron bunches with a beam charge above 300 pC and divergence of around 12 mrad show the injection probability over 90% after optimizing the ablation laser energy and the temporal delay between the ablation and the main laser pulses. Since this nanoparticle insertion method can avoid the disturbing effects of electron injection process on laser evolution, the stable high-charge injection method can provide a suitable electron injector for multi-GeV electron sources from low-density plasmas.

19.
Rev Sci Instrum ; 93(11): 113311, 2022 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-36461536

RESUMEN

The absolute response of a real-time proton detector, composed of a microchannel plate (MCP) assembly, an imaging lens, and a charge-coupled device (CCD) camera, is calibrated for the spectral characterization of laser-accelerated protons, using a Thomson parabola spectrometer (TPS). A slotted CR-39 plate was used as an absolute particle-counting detector in the TPS, simultaneously with the MCP-CCD detector to obtain a calibration factor (count/proton). In order to obtain the calibration factor as a function of proton energy for a wide range of proton numbers, the absolute response was investigated for different operation parameters of the MCP-CCD detector, such as MCP voltage, phosphor voltage, and CCD gain. A theoretical calculation for the net response of the MCP was in good agreement with the calibrated response of the MCP-CCD detector, and allows us to extend the response to higher proton energies. The response varies in two orders of magnitude, showing an exponential increase with the MCP voltage and almost linear increase with the phosphor voltage and the CCD gain. The calibrated detector enabled characterization of a proton energy spectrum in a wide dynamic range of proton numbers. Moreover, two MCP assemblies having different structures of MCP, phosphor screen, and optical output window have been calibrated, and the difference in the absolute response was highlighted. The highly-sensitive detector operated with maximum values of the parameters enables measuring a single proton particle and evaluating an absolute spectrum at high proton energies in a single laser shot. The absolute calibrations can be applied for the spectral measurement of protons using different operating voltages and gains for optimized response in a large range of proton energy and number.

20.
Opt Lett ; 36(22): 4443-5, 2011 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-22089591

RESUMEN

We demonstrate sub-100-as timing jitter optical pulse trains generated from free-running, 77.6 MHz repetition-rate, mode-locked Er-fiber lasers. At -0.002(±0.001) ps2 net cavity dispersion, the rms timing jitter is 70 as (224 as) integrated from 10 kHz (1 kHz) to 38.8 MHz offset frequency, when measured by a 24 as resolution balanced optical cross correlator. To our knowledge, this result corresponds to the lowest rms timing jitter measured from any mode-locked fiber lasers so far. The measured result also agrees fairly well with the Namiki-Haus analytic model of quantum-limited timing jitter in stretched-pulse fiber lasers.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA