Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Eur J Orthop Surg Traumatol ; 33(5): 1841-1847, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35984517

RESUMEN

PURPOSE: Surgical trauma may confer additional infectious risk after operative fixation for high energy tibial plateau fractures. This study aims to determine the impact of plate number and location on infection rates after these injuries. METHODS: This retrospective cohort study completed at two level one trauma centers included patients who underwent staged fixation for a tibial plateau fracture between 2015 and 2019. Plate number and location (lateral, medial, posteromedial, and anterior quadrants) used in the definitive fixation construct were collected from post-operative radiographs. Deep infection rate was primary the outcome. RESULTS: A total of 244 patients met inclusion criteria. The overall infection rate was 13.9% (34/244). Infection rates increased with each additional quadrant utilized (8.0% one quadrant, 13.0% two quadrants, 27.3% three quadrants, 100% four quadrants; p < 0.001), independent of plate number, fracture severity, operative time, number of incisions, external fixator pin and plate construct overlap, and days in the external fixator on multivariate analysis. CONCLUSIONS: Infection risk increases with each quadrant utilized in the fixation of high energy tibial plateau fractures. Providers should attempt to limit the dissection of soft tissue for hardware placement in the fixation of these injuries to limit infection risk. LEVEL OF EVIDENCE: Level III, retrospective therapeutic study.


Asunto(s)
Herida Quirúrgica , Fracturas de la Tibia , Fracturas de la Meseta Tibial , Humanos , Estudios Retrospectivos , Fracturas de la Tibia/cirugía , Fijación de Fractura , Fijadores Externos/efectos adversos , Fijación Interna de Fracturas/efectos adversos , Placas Óseas/efectos adversos , Resultado del Tratamiento
2.
Eur J Orthop Surg Traumatol ; 33(5): 1929-1935, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36036821

RESUMEN

PURPOSE: The treatment of nonunion of long bones is difficult particularly in the presence of infection, which often involves staged surgical management. There is limited literature to compare the post operative course and outcomes of patients treated for septic versus aseptic nonunion. Thus, the purpose of this study was to determine if a difference exists between the number of surgical procedures, time to union, and rate of successful union for these two groups. METHODS: A retrospective cohort study was performed at a single tertiary care center. Patients suffering nonunion of the humerus, tibia and femur were included. Patient demographic data and characteristics of the post operative course were collected to include number and reason for repeat operations, antibiotic course, time to union, and development of a successful union. RESULTS: About 28 of 122 patients had septic nonunion. After diagnosis of nonunion, the septic group averaged 3.9 surgeries compared to 1.5 in the aseptic group (p < 0.001). There was no difference in the rate of successful union (79.8% versus 85.7%; p = 0.220), though the septic group took 129 days longer on average for successful union. (376 versus 247; p = 0.018). CONCLUSION: Septic nonunion of long bones is associated with the need for significantly more operations as well as time to union, though union rates remain similar. The identification of infection is critical for both the appropriate treatment as well as counseling patients on the expected post operative course.


Asunto(s)
Fracturas no Consolidadas , Humanos , Fracturas no Consolidadas/cirugía , Estudios Retrospectivos , Tibia/cirugía , Fémur , Húmero/cirugía , Resultado del Tratamiento , Curación de Fractura
3.
Eur J Orthop Surg Traumatol ; 33(5): 1827-1833, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35982192

RESUMEN

PURPOSE: External fixator pin site overlap with definitive fixation implants (pin-plate overlap) has been identified as a risk factor for surgical site infection in tibial plateau fractures. Despite this, pin-plate overlap occurs in 24-38% of patients. This study sought to identify radiographic characteristics associated with pin-plate overlap to help minimize occurrences. METHODS: 283 patients at two Level I trauma centers were retrospectively reviewed. Radiographic measurements were recorded including fracture length, distance from fracture to proximal tibial pin site, and pin site distance-to-fracture (PSF) ratio. RESULTS: 70 (24.7%) cases of pin-plate overlap were identified. Pin-plate overlap was associated with increased fracture length (81.5 ± 32.1 mm vs 56.9 ± 26.1 mm, p < 0.001) and decreased distance from fracture to proximal tibial pin site (84.5 ± 37.1 mm vs 126.9 ± 35.8 mm). Pins placed greater than 100 mm and 150 mm from the fracture eliminated 36/70 (51%) and 67/70 (96%) pin-plate overlaps, respectively. Pins placed with a PSF ratio greater than 1.5 and 2.0 eliminated 47/70 (67%), and 57/70 (81%) of pin-plate overlaps, respectively. CONCLUSIONS: Longer fractures, pins closer to the fracture, and decreased PSF ratio were associated with overlap. Placing proximal tibial pins more than 100 mm from the fracture eliminated most pin-plate overlaps.


Asunto(s)
Fracturas de la Tibia , Fracturas de la Meseta Tibial , Humanos , Estudios Retrospectivos , Fijadores Externos , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/cirugía , Fijación de Fractura/efectos adversos
4.
J Pediatr Orthop ; 39(3): 119-124, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30730415

RESUMEN

BACKGROUND: Factors including obesity and morphologic parameters around the hip that increase physeal stress are associated with an increased risk of slipped capital femoral epiphysis (SCFE). Recent evidence suggests that superior epiphyseal extension may confer stability to the physis and help protect against SCFE. The purpose of this study is to investigate the relationship between epiphyseal extension and SCFE using an age-matched and sex-matched cohort study. METHODS: We generated 2 separate cohorts for comparison: 89 patients with unilateral SCFE and 89 healthy subjects with no evidence of hip disease or deformity. We utilized the anterior-posterior and lateral films of the hip to measure the Southwick angle and the epiphyseal extension ratio (EER), defined as the ratio of extension of the capital femoral epiphysis down the femoral neck relative to the diameter of the femoral head. We then compared these measurements between cohorts and in subgroup analysis based on slip stability and whether subjects progressed to a contralateral slip. RESULTS: The SCFE cohort demonstrated a decreased superior epiphyseal extension ratio compared with control (superior EER 0.71 vs. 0.68, P=0.002). There was also a significant downward trend in superior EER from the control subjects (0.71±0.07) to the stable slips (0.69±0.06) to the unstable slips (0.65±0.04) with an overall difference between the groups (P=0.001). Eighteen of 44 (41%) subjects with unilateral stable slips and at least 6 months of follow-up went on to develop SCFE of the contralateral limb. The subjects who developed contralateral slips were younger (11.6±1.2 vs. 12.7±1.4 y, P=0.008); however, there was no difference in superior or anterior epiphyseal extension (P=0.75 and 0.23, respectively). There was no significant linear correlation between Southwick angle and superior or anterior EER (r=0.13 and 0.17, respectively, P>0.05 for both). CONCLUSIONS: Increasing capital femoral epiphyseal extension may confer physeal stability in the setting of SCFE. We propose that this epiphyseal extension reflects an adaptive response to limit physeal stress and reduce the risk for progression to SCFE. LEVEL OF EVIDENCE: Level III-prognostic study.


Asunto(s)
Cabeza Femoral , Cuello Femoral , Placa de Crecimiento , Articulación de la Cadera , Epífisis Desprendida de Cabeza Femoral/diagnóstico , Adolescente , Pesos y Medidas Corporales/métodos , Niño , Estudios de Cohortes , Progresión de la Enfermedad , Femenino , Cabeza Femoral/diagnóstico por imagen , Cabeza Femoral/fisiopatología , Cuello Femoral/diagnóstico por imagen , Cuello Femoral/fisiopatología , Placa de Crecimiento/diagnóstico por imagen , Placa de Crecimiento/fisiopatología , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/fisiopatología , Humanos , Masculino , Pronóstico , Medición de Riesgo/métodos , Factores de Riesgo , Epífisis Desprendida de Cabeza Femoral/etiología , Epífisis Desprendida de Cabeza Femoral/fisiopatología
5.
J Pediatr Orthop ; 38(4): 202-207, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27261970

RESUMEN

BACKGROUND: Unstable slipped capital femoral epiphysis (SCFE) has an increased incidence of avascular necrosis (AVN). Early identification and surgical intervention for AVN may help preserve the femoral head. METHODS: We retrospectively reviewed 48 patients (50 hips) with unstable SCFE managed between 2000 and 2014. AVN was diagnosed based on 2 different postoperative protocols. Seventeen patients (17 hips) had a scheduled magnetic resonance imaging (MRI) between 1 and 6 months from initial surgery, and the remaining 31 patients (33 hips) were evaluated by plain radiographs alone. If AVN was diagnosed, we offered core decompression and closed bone graft epiphysiodesis (CBGE) to mitigate its affects. At final follow-up, we assessed progression of AVN using the Steinberg classification. RESULTS: Overall 13 hips (26%) with unstable SCFEs developed AVN. MRI revealed AVN in 7 of 17 hips (41%) at a mean of 2.5 months postoperatively (range, 1.0 to 5.2 mo). Six hips diagnosed by MRI received surgical intervention (4 CBGE, 1 free vascularized fibula graft, and 1 repinning due to screw cutout) at a mean of 4.1 months (range, 1.3 to 7.2 mo) postoperatively. None of the 4 patients treated with CBGE within 2 months postoperatively progressed to stage IVC AVN. The 2 patients treated after 4 months postoperatively both progressed to stage VC AVN.Plain radiographs demonstrated AVN in 6 of 33 hips (18%) at a mean of 6.8 months postoperatively (range, 2.1 to 21.1 mo). One patient diagnosed with stage IVB AVN at 2.4 months had screw cutout and received CBGE at 2.5 months from initial pinning. The remaining 5 were not offered surgical intervention. Five of the 6 radiographically diagnosed AVN, including the 1 treated with CBGE, progressed to stage IVC AVN or greater. CONCLUSIONS: Although all patients with positive MRI scans developed radiographic AVN, none of the 4 patients treated with CBGE within 2 months after pinning developed grade IVC or greater AVN. Early MRI detection and CBGE may mitigate the effects of AVN after SCFE. LEVEL OF EVIDENCE: Level III-retrospective comparative study.


Asunto(s)
Artrodesis/métodos , Trasplante Óseo/métodos , Necrosis de la Cabeza Femoral/diagnóstico por imagen , Epífisis Desprendida de Cabeza Femoral/diagnóstico , Epífisis Desprendida de Cabeza Femoral/cirugía , Adolescente , Niño , Diagnóstico Precoz , Femenino , Cabeza Femoral/cirugía , Necrosis de la Cabeza Femoral/etiología , Necrosis de la Cabeza Femoral/fisiopatología , Necrosis de la Cabeza Femoral/cirugía , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/cirugía , Humanos , Imagen por Resonancia Magnética , Masculino , Radiografía , Estudios Retrospectivos , Medición de Riesgo , Epífisis Desprendida de Cabeza Femoral/complicaciones , Epífisis Desprendida de Cabeza Femoral/fisiopatología
7.
Clin Orthop Relat Res ; 474(6): 1453-8, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26847454

RESUMEN

BACKGROUND: Knee dislocations are rare injuries with potentially devastating vascular complications. An expeditious and accurate diagnosis is necessary, as failing to diagnose vascular injury can result in amputation; however, the best diagnostic approach remains controversial. QUESTIONS/PURPOSES: We asked: (1) What patient factors are predictors of vascular injury after knee dislocation? (2) What are the diagnostic utilities of palpable dorsalis pedis or posterior tibial pulses, and the presence of an ankle-brachial index (ABI) of 0.9 or greater? METHODS: A database at a Level I trauma center was queried for patients with evidence of knee dislocation, demographic information (age at the time of injury, sex, Injury Severity Score, BMI, mechanism of injury), and the presence of open injury were recorded. One-hundred forty-one patients underwent screening at initial presentation, of whom 26 (24%) underwent early vascular exploration based on an abnormal physical examination. One-hundred five (91%) of the remaining 115 patients were available at a minimum followup of 6 months (mean, 19 ± 10 months). In total, 31 unique patients were excluded, including 10 patients (7%) who were lost to followup before 6 months. Among the 110 patients who met inclusion criteria, the mean age and SD was 37 ± 13 years, and the Injury Severity Score was 15 ± 9. There were 71 males (65%). Logistic regression was used to determine independent correlates of vascular injury. The vascular examination was reviewed for the presence of a palpable pulse in the dorsalis pedis artery, the presence of a palpable pulse in the posterior tibial artery, and whether the ABI in the dorsalis pedis was 0.9 or greater. Contingency tables were generated to assess the sensitivity, specificity, and accuracy of physical examination maneuvers. The physical examination was collectively regarded as "normal" when both pulses were palpable and the ABI was 0.9 or greater. The initial physical examination as just described was considered the diagnostic test being evaluated in this study; "positive" tests were evaluated by and confirmed at vascular surgery, and 6 months clinical followup without symptoms or progressive signs of vascular injury confirmed the absence of injury in the remainder of the patients. Contingency tables were generated again to assess the sensitivity, specificity, and accuracy of the combined physical examination. RESULTS: Increased BMI (odds ratio [OR], 1.077; 95% CI, 1.008-1.155; p = 0.033) and open injuries (OR, 3.366; 95% CI, 1.008-11.420; p = 0.048) were associated with vascular injury. No single physical examination maneuver had a 100% sensitivity for ruling out vascular injury. A normal physical examination (palpable pulses and ABI ≥ 0.9) had 100% sensitivity for ruling out vascular injury. CONCLUSIONS: Increased BMI and the presence of open dislocation are associated with a greater risk for vascular injury after knee dislocation. The combination of a palpable dorsalis pedis and posterior tibial pulse combined with an ABI of 0.9 or greater was 100% sensitive for the detection of vascular injury based on clinical followup at 6 months. LEVEL OF EVIDENCE: Level III, diagnostic study.


Asunto(s)
Índice Tobillo Braquial , Luxación de la Rodilla/complicaciones , Traumatismos de la Rodilla/complicaciones , Palpación , Lesiones del Sistema Vascular/diagnóstico , Adulto , Femenino , Humanos , Puntaje de Gravedad del Traumatismo , Luxación de la Rodilla/diagnóstico , Traumatismos de la Rodilla/diagnóstico , Modelos Logísticos , Masculino , Persona de Mediana Edad , Oportunidad Relativa , Valor Predictivo de las Pruebas , Sistema de Registros , Reproducibilidad de los Resultados , Factores de Riesgo , Centros Traumatológicos , Lesiones del Sistema Vascular/etiología , Adulto Joven
8.
J Orthop Trauma ; 37(4): 195-199, 2023 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-36730006

RESUMEN

OBJECTIVES: To determine if patients suffering simple, posterior hip dislocations are more likely to display dysplastic characteristics of their acetabulum as compared with those suffering fracture dislocations. DESIGN: Retrospective cohort study. SETTING: Level 1 trauma center. PATIENTS/PARTICIPANTS: Eighty-six patients suffering posterior, native hip dislocations over a 5-year period. MAIN OUTCOME MEASUREMENT: The primary outcome was measurement of the lateral center edge angle (LCEA), acetabular index (AI), acetabular version, and femoro-epiphyseal acetabular roof (FEAR) index. RESULTS: Eighteen patients (20.9%) sustained simple dislocations, whereas 68 patients (79.1%) suffered fracture dislocations. Patients with simple dislocations had decreased LCEA (25.7 vs. 34.3; P < 0.001), increased AI (7.4 vs. 5.8; P = 0.019), and decreased acetabular anteversion (14.02 vs. 18.45; P = 0.011). Additionally, patients with simple dislocations had higher rates of dysplasia and borderline dysplasia (61.1% vs. 7.3%; P < 0.001). Patients with fracture dislocations had higher rates of concomitant injuries (60.9% vs. 29.4%; P = 0.039) and higher injury severity scores (8.1 vs. 12.3; P = 0.022). CONCLUSION: Patients who sustain simple hip dislocations are more likely to have undercoverage of the femoral head by the acetabulum as compared with patients suffering fracture dislocations. In addition, the simple dislocation group had a lower ISS and fewer concomitant injuries, which likely relates to a lower energy required for dislocation in the setting of lesser bony constraint. Surgeons treating these complicated injuries should consider measurements of LCE and AI when counseling patients on treatment strategies. LEVEL OF EVIDENCE: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.


Asunto(s)
Fractura-Luxación , Luxación de la Cadera , Humanos , Luxación de la Cadera/epidemiología , Luxación de la Cadera/cirugía , Estudios Retrospectivos , Acetábulo/cirugía , Cabeza Femoral/cirugía , Articulación de la Cadera/cirugía
9.
Cureus ; 15(5): e38561, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37284362

RESUMEN

Introduction Postoperative stiffness is a common complication after high-energy tibial plateau fractures. Investigation into reported surgical techniques for the prevention of postoperative stiffness is limited. The purpose of this study was to compare the rates of postoperative stiffness after second-stage definitive surgery for high-energy tibial plateau fractures between groups of patients who had the external fixator prepped into the surgical field and those who did not. Methods Two hundred forty-four patients met the inclusion criteria between the two academic Level I trauma centers, representing the retrospective observational cohort. Patients were separated based on prepping of the external fixator into the surgical field during second-stage definitive open reduction and internal fixation. One hundred sixty-two patients were in the prepped group and 82 were in the non-prepped group. Post-operative stiffness was determined by the need to return to the operating room for subsequent procedures. Results At the final follow-up (mean = 14.6 months), patients in the non-prepped group had an increased rate of stiffness post-operatively (18.3% non-prepped versus 6.8% prepped; p = 0.006). No other investigated variables were associated with increased post-operative stiffness, including the number of days spent in the fixator and operative time. The relative risk for post-operative stiffness associated with complete fixator removal was 2.54 (95% CI 1.26-4.41; p = 0.008 on binary logistic regression; absolute risk reduction 11.5%). Conclusion At the final follow-up, maintenance of an intraoperative external fixator as a reduction aid was associated with a clinically significant decrease in post-operative stiffness after definitive management of high-energy tibial plateau fractures, when compared with complete removal prior to prepping.

10.
Injury ; 54(7): 110754, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37188588

RESUMEN

INTRODUCTION: Distal femur fractures are common injuries that remain difficult for orthopedic surgeons to treat. High complication rates, including nonunion rates as high as 24% and infection rates of 8%, can lead to increased morbidity for these patients. Allogenic blood transfusions have previously been identified as risk factors for infection in total joint arthroplasty and spinal fusion surgeries. No studies have explored the relationship between blood transfusions and fracture related infection (FRI) or nonunion in distal femur fractures. METHODS: 418 patients with operatively treated distal femur fractures at two level I trauma centers were retrospectively reviewed. Patient demographics were collected including age, gender, BMI, medical comorbidities, and smoking. Injury and treatment information was also collected including open fracture, polytrauma status, implant, perioperative transfusions, FRI, and nonunion. Patients with less than three months of follow up were excluded. RESULTS: 366 patients were included in final analysis. One hundred thirty-nine (38%) patients received a perioperative blood transfusion. Forty-seven (13%) nonunions and 30 (8%) FRI were identified. Allogenic blood transfusion was not associated with nonunion (13% vs 12%, P = 0.87), but was associated with FRI (15% vs 4%, P<0.001). Binary logistic regression analysis identified a dose dependent relationship between number of perioperative blood transfusions and FRI: total transfusion ≥2 U PRBC RR= 3.47(1.29, 8.10, P = 0.02), ≥3 RR= 6.99 (3.01, 12.40, P<0.001), and ≥4 RR= 8.94 (4.03, 14.42, P<0.001). DISCUSSION: In patients undergoing operative treatment of distal femur fractures, perioperative blood transfusions are associated with increased risk of fracture related infection, but not the development of a nonunion. This risk association increases in a dose-dependent relationship with increasing total blood transfusions received.


Asunto(s)
Fracturas Femorales Distales , Fracturas del Fémur , Humanos , Estudios Retrospectivos , Resultado del Tratamiento , Fracturas del Fémur/epidemiología , Fracturas del Fémur/cirugía , Fracturas del Fémur/etiología , Fémur/cirugía , Fijación Interna de Fracturas/efectos adversos , Curación de Fractura
11.
JBJS Case Connect ; 13(1)2023 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-36928114

RESUMEN

CASE: A 53-year-old woman with a history of transfemoral amputation presented to the emergency department with an ipsilateral intertrochanteric femur fracture. Standard fracture tables that use a boot to pull traction are not helpful in these cases, which makes achieving adequate traction for reduction difficult. CONCLUSION: We describe a unique technique to manipulate an amputated extremity using 2 Schanz pins attached to a weight through a traction rope. This practical technique provided adequate skeletal traction for reduction and internal fixation in our case and can be performed on a standard radiolucent table without the need for special table attachments.


Asunto(s)
Fracturas de Cadera , Tracción , Femenino , Humanos , Persona de Mediana Edad , Tracción/métodos , Fracturas de Cadera/cirugía , Fijación Interna de Fracturas , Amputación Quirúrgica , Fémur/cirugía
12.
Injury ; 54(7): 110759, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37156699

RESUMEN

INTRODUCTION: High energy tibial plateau fractures are fraught with complications, particularly fracture-related infection (FRI). Previous studies have evaluated patient demographics, fracture classification, and injury characteristics as risk factors for FRI in patients with these injuries. This study evaluated the relationship between radiographic parameters (fracture length relative to femoral condyle width (FLF ratio), initial femoral displacement (FD ratio), and tibial widening (TW ratio)) and fracture-related infection following internal fixation in high energy bicondylar tibial plateau fractures. METHODS: 225 patients treated for bicondylar tibial plateau fractures at two level I trauma centers were retrospectively reviewed. Patient characteristics, fracture classification, and radiographic measurements were analyzed to determine association with FRI. RESULTS: The rate of FRI was 13.8%. Increased fracture length, FLF ratio, FD ratio, TW ratio, and fibula fracture were each associated with FRI on regression analysis, independent of clinical variables. Cutoff values were identified for each parameter and patients were risk stratified based on these radiographic parameters. High-risk patients had a 2.68- and 12.36-times risk of FRI compared to medium and low-risk patients, respectively. DISCUSSION: This study is the first to examine the relationship between radiographic parameters and FRI in high energy bicondylar tibial plateau fractures. Fracture length, FLF ratio, FD ratio, TW ratio, and fibula fracture were identified as radiographic parameters associated with FRI. More importantly, risk stratifying patients based on these parameters accurately identified patients at increased risk of FRI. Not all bicondylar tibial plateau fractures are created equal and radiographic parameters can be utilized to help identify the bad actors.


Asunto(s)
Fracturas de la Tibia , Fracturas de la Meseta Tibial , Humanos , Estudios Retrospectivos , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/cirugía , Fijación Interna de Fracturas/efectos adversos , Tibia
13.
Strategies Trauma Limb Reconstr ; 17(3): 189-194, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36756295

RESUMEN

Aim: To describe the surgical technique of performing an all-internal lengthening to address a large diaphyseal femur defect in the sarcoma patient. Background: Various strategies exist to address large intercalary bone defects with various biomechanical and biological implications. Case description: A 23-year-old female with high-grade osteosarcoma of her left femur underwent wide resection and an internal reconstruction of a 12.5-cm femoral defect using dual magnetic lengthening intramedullary nails resulting in restoration of leg lengths, and pre-resection function with minimal residual disability. Conclusion: Preoperative chemotherapy, wide resection and post-operative chemotherapy for osteosarcoma are the current standard of care. Resection often leads to large bone defects requiring complex reconstruction. Following intercalary bone resection, biological reconstruction is a consideration. An all-inside technique was developed in an effort to minimise complications of long-term external fixation for distraction osteogenesis, or extensile secondary grafting procedures for induced membrane strategy. Clinical significance: This previously unreported surgical technique allows for an all-internal lengthening of large diaphyseal bone defects. While specifically used in an oncologic post-resection setting, this technique is applicable to the broader limb reconstruction and lengthening practice and overcomes some inherent limitations to previously described techniques. How to cite this article: Copp J, Magister S, Napora J, et al. Dual Magnetically Expandable Intramedullary Nails for Treatment of a Large Bony Defect in a Patient with Sarcoma: A Case Report. Strategies Trauma Limb Reconstr 2022;17(3):189-194.

14.
J Orthop Trauma ; 36(10): 530-534, 2022 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-35470324

RESUMEN

OBJECTIVES: To compare infection rates after second-stage definitive surgery for high-energy tibial plateau fractures between groups of patients who had the external fixator prepped into the surgical field and those who did not. DESIGN: Retrospective cohort study. SETTING: Two academic Level 1 trauma centers. PATIENTS/PARTICIPANTS: Two hundred forty-four patients met inclusion and exclusion criteria between the 2 institutions. INTERVENTION: Prepping of the external fixator into the surgical field during second-stage definitive open reduction and internal fixation. 162 patients were in the prepped group, and 82 patients were in the nonprepped group. MAIN OUTCOME MEASUREMENTS: The primary outcome was the rate of deep infection after definitive fixation. Secondary outcome was operative time. RESULTS: There were no significant differences in infection rates between prepped (11.7%) and nonprepped (18.3%) groups ( P = 0.162). Patients in the prepped groups had significantly decreased operative time (168.2 minutes vs. 221.9 minutes, P < 0.001) even after controlling for confounders in regression analysis. CONCLUSIONS: There is no increased risk of infection associated with prepping and maintenance of the external fixator during definitive internal fixation for high-energy tibial plateau fractures. These data suggest that this practice may lead to shorter operative times as well. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.


Asunto(s)
Fracturas de la Tibia , Fijadores Externos , Fijación Interna de Fracturas/efectos adversos , Humanos , Estudios Retrospectivos , Esterilización , Fracturas de la Tibia/epidemiología , Fracturas de la Tibia/etiología , Fracturas de la Tibia/cirugía , Resultado del Tratamiento
15.
Injury ; 53(4): 1504-1509, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35067341

RESUMEN

INTRODUCTION: Despite advances in the treatment of high energy proximal tibia fractures, including the utilization of staged management with external fixation, the infection rate remains high. Overlap between external fixator pin sites and definitive internal fixation has been proposed as a risk factor for infection. METHODS: This retrospective study reviews 244 patients with staged knee-spanning external fixation followed by delayed definitive internal fixation at two separate level one trauma centers. Presence of pin-plate overlap as well as several other known risk factors for infection were recorded and measured to include open fractures, compartment syndrome, operative time and number of incisions. Development of deep infection was the primary outcome. Both univariate and multivariate statistics were applied to determine differences in rates of infection. RESULTS: 65 (26.6%) patients had presence of pin-plate overlap while 179 (73.4%) patients had no overlap. There were no differences between overlapping and non-overlapping groups with respect to other infectious risk factors. Deep infection occurred in 34 (13.9%) total patients, 18 (27.7%) were in patients with pin-plate overlap and 16 (8.9%) in those without overlap. (P = 0.003; RR 3.01, 95% CI 1.51-4.76). DISCUSSION: This large, multicenter study demonstrated a statistically significant association between pin-plate overlap and the development of deep infection in tibial plateau fractures. On multivariate analysis, pin-plate overlap was identified as an independent risk factor for infection. When treating these complex injuries, surgeons should consider the definitive fixation construct when placing external fixation pins.


Asunto(s)
Infección de la Herida Quirúrgica , Fracturas de la Tibia , Fijadores Externos/efectos adversos , Fijación de Fractura/métodos , Fijación Interna de Fracturas/efectos adversos , Fijación Interna de Fracturas/métodos , Humanos , Estudios Retrospectivos , Infección de la Herida Quirúrgica/etiología , Fracturas de la Tibia/complicaciones , Fracturas de la Tibia/cirugía , Resultado del Tratamiento
16.
J Orthop Trauma ; 35(6): 289-295, 2021 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-33967224

RESUMEN

OBJECTIVE: To analyze the correlation between surgical timing and outcomes for calcaneus fractures treated using a sinus tarsi approach (STA). SETTING: Single Level-1 trauma center. DESIGN: Retrospective. PATIENTS/PARTICIPANTS: Seventy consecutive intra-articular calcaneus fractures (OTA/AO 82C; Sanders II-IV) treated operatively using STA with a minimum of 1-year follow-up. INTERVENTION: Open management using STA. MAIN OUTCOME MEASUREMENT: Surgery timing, wound complications, American Orthopaedic Foot and Ankle Society ankle and hindfoot and Patient-reported Outcomes Measurement System scores. RESULTS: Patients were primarily men (68.6%) averaging 46 years (range, 18-77 years). Nineteen (27%) were obese, 27 (38.6%) were smokers, and 3 (4.3%) were diabetic, and 10 (14.3%) had open fractures. Sanders III fracture patterns were most common (45.7%). Mean time to surgery was 4.9 days (range, 0-23 days). Three patients (4.2%) developed postoperative infections requiring surgical debridement and antibiotics. Forty patients (57%) underwent operative repair within 72 hours of injury, 9 (22.5%) of which had open fractures. Of this group, only one patient developed wound necrosis. Restoration of Bohler angle and angle of Gissane and reductions in calcaneal varus angle and heel width were achieved (all P < 0.001). No differences in Ankle Society ankle and hindfoot or Patient-reported Outcomes Measurement System scores were noted between patients treated within or beyond 72 hours from injury. CONCLUSION: Intra-articular calcaneus fractures can be treated acutely within 72 hours of injury using STA with minimal wound complications and without compromising short-term functional outcome. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.


Asunto(s)
Calcáneo , Fracturas Óseas , Fracturas Intraarticulares , Calcáneo/diagnóstico por imagen , Calcáneo/cirugía , Fijación Interna de Fracturas , Fracturas Óseas/cirugía , Talón , Humanos , Fracturas Intraarticulares/diagnóstico por imagen , Fracturas Intraarticulares/cirugía , Masculino , Estudios Retrospectivos , Resultado del Tratamiento
17.
OTA Int ; 4(4): e159, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34805774

RESUMEN

OBJECTIVES: To compare the number of patients with gunshot wounds presenting to our level 1 trauma center before and during the COVID-19 pandemic with a focus on volume trends after the lifting of stay-at-home directives through August 2020. DESIGN: Retrospective. SETTING: Level 1 trauma center. PATIENTS/PARTICIPANTS: Seven hundred six gunshot wound patients between 2016 and 2020 (months March to September only). INTERVENTION: COVID-19 pandemic and resultant stay at home directives. MAIN OUTCOME MEASUREMENTS: Number of patients presenting with gunshot wounds per time period. RESULTS: The number of patients with gunshot wounds presenting to our institution increased by 11.7% in March-April 2020 and by 67% in May-August 2020 when compared to previous years. Length of stay significantly decreased in 2020 compared to 2018 and 2019. In 2020, significantly fewer patients had orthopaedic procedures than in 2018. CONCLUSIONS: Patients presenting with gunshot wounds increased during the initial "stay-at-home" portion of the pandemic in March to April and increased significantly more after the restrictions were relaxed during May to August.Level of Evidence: Therapeutic Level III.

18.
Orthopedics ; 44(2): 92-97, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33561873

RESUMEN

The standard treatment of stable slipped capital femoral epiphysis (SCFE) is generally accepted to be in situ pinning. Controversy exists regarding the treatment of unstable SCFE, including the role of a purposeful closed reduction or open reduction. The objective of this study was to investigate the rate of avascular necrosis (AVN) with purposeful closed reduction and in situ pinning of unstable SCFE. The authors retrospectively reviewed 221 patients with 302 SCFE hips treated with in situ pinning between 2000 and 2014. Forty-eight patients (50 hips) presented with an unstable SCFE. All unstable SCFEs were treated by a gentle reduction method with traction and hip internal rotation followed by pinning. Southwick angles were measured prior to reduction and at the first postoperative visit. No stable SCFEs developed AVN. Thirteen (26%) unstable SCFEs developed AVN. Avascular necrosis developed in 7 of 17 (41%) hips screened with magnetic resonance imaging vs 6 of 33 (18%) hips screened with plain radiographs alone. Mean change in Southwick angle was 28°±8° in the AVN group vs 18°±18° in the no AVN group (P=.18). Despite potentially inflating the rate with the use of early detection magnetic resonance imaging, the authors found an AVN rate comparable to that in the published literature with the use of gentle purposeful reduction on a fracture table, and no statistical differences in reduction amount between patients with and without AVN. Gentle purposeful reduction appears to be a reasonable low morbidity option in the treatment of unstable SCFE without a clear increase in risk of AVN. [Orthopedics. 2021;44(2):92-97.].


Asunto(s)
Necrosis de la Cabeza Femoral/etiología , Procedimientos de Cirugía Plástica/efectos adversos , Epífisis Desprendida de Cabeza Femoral/cirugía , Adolescente , Niño , Humanos , Imagen por Resonancia Magnética , Masculino , Complicaciones Posoperatorias/etiología , Radiografía , Estudios Retrospectivos , Epífisis Desprendida de Cabeza Femoral/diagnóstico por imagen
19.
J Orthop Trauma ; 35(5): 239-244, 2021 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-32956208

RESUMEN

OBJECTIVES: To assess the reliability of the current computed tomography (CT)-based technique for determining femoral anteversion and quantify the prevalence and magnitude of side-to-side differences. DESIGN: Cross-sectional cohort study. SETTING: Academic trauma center. PATIENTS: We reviewed CT scans from 120 patients with bilateral full-length axial cuts of both femurs. Two hundred forty femurs with no fractures or other identifying features in their femora were included. Ten unique data sets were created to measure anteversion of the left and right sides. MAIN OUTCOME MEASUREMENTS: Intraobserver and interobserver reliability were calculated using intraclass correlation coefficients (ICCs) and pooled absolute differences. The mean absolute difference between the sides was determined using a fixed-effects model. RESULTS: Interobserver reliability was high (ICC: 0.85, 95% confidence interval [CI]: 0.83-0.88). The pooled mean absolute magnitude of variation between reviewers was small at 1.6 degrees (95% CI: 1.4-1.8 degrees) per scan. The intraobserver reproducibility was high (ICC: 0.91, 95% CI: 0.88-0.93) with a mean error of 2.7 degrees (95% CI: 2.2-3.1 degrees) per repeat viewing of the same scan by the same person. The magnitude of side-to-side variation was 2.0 degrees (95% CI: 1.5-2.6 degrees). Twenty-one subjects (18%, 95% CI: 12%-25%) had a mean side-to-side calculated femoral anteversion difference of ≥10 degrees, whereas 6 (5%, 95% CI: 2-10) subjects had a calculated mean side-to-side difference of ≥15 degrees. CONCLUSIONS: CT based femoral anteversion measurement techniques demonstrate good precision. Only 1 in 20 patients had side-to-side differences of 15 degrees or more.


Asunto(s)
Fémur , Tomografía Computarizada por Rayos X , Estudios Transversales , Fémur/diagnóstico por imagen , Fémur/cirugía , Humanos , Reproducibilidad de los Resultados , Rotación
20.
Tech Hand Up Extrem Surg ; 24(3): 119-125, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31923043

RESUMEN

Treatment of ulnar diaphyseal fractures can range broadly from nonoperative with immobilization to surgical intervention with a variety of implants or approaches. At a Level 1 trauma center, a series of ulnar shaft fractures have been treated using a percutaneous plating technique that is base beneath the extensor carpi ulnaris. This technique description illustrates relevant anatomy, important patient and injury characteristics, implant considerations, and potential outcomes and complications. The described treatment option provides an effective way of spanning comminuted fracture patterns without disrupting the surrounding biology while providing stable fixation. An associated patient series is included which enumerates associated injuries and describes limited follow-up. In the multiply injured trauma patient, such a fixation method also had potential benefits for their overall care and rehabilitation.


Asunto(s)
Placas Óseas , Fijación Interna de Fracturas/métodos , Fracturas del Cúbito/cirugía , Adolescente , Adulto , Anciano , Contraindicaciones de los Procedimientos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Cúbito/anatomía & histología , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA