Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Neuroimage ; 240: 118367, 2021 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-34237442

RESUMEN

Diffusion MRI (dMRI) has become an invaluable tool to assess the microstructural organization of brain tissue. Depending on the specific acquisition settings, the dMRI signal encodes specific properties of the underlying diffusion process. In the last two decades, several signal representations have been proposed to fit the dMRI signal and decode such properties. Most methods, however, are tested and developed on a limited amount of data, and their applicability to other acquisition schemes remains unknown. With this work, we aimed to shed light on the generalizability of existing dMRI signal representations to different diffusion encoding parameters and brain tissue types. To this end, we organized a community challenge - named MEMENTO, making available the same datasets for fair comparisons across algorithms and techniques. We considered two state-of-the-art diffusion datasets, including single-diffusion-encoding (SDE) spin-echo data from a human brain with over 3820 unique diffusion weightings (the MASSIVE dataset), and double (oscillating) diffusion encoding data (DDE/DODE) of a mouse brain including over 2520 unique data points. A subset of the data sampled in 5 different voxels was openly distributed, and the challenge participants were asked to predict the remaining part of the data. After one year, eight participant teams submitted a total of 80 signal fits. For each submission, we evaluated the mean squared error, the variance of the prediction error and the Bayesian information criteria. The received submissions predicted either multi-shell SDE data (37%) or DODE data (22%), followed by cartesian SDE data (19%) and DDE (18%). Most submissions predicted the signals measured with SDE remarkably well, with the exception of low and very strong diffusion weightings. The prediction of DDE and DODE data seemed more challenging, likely because none of the submissions explicitly accounted for diffusion time and frequency. Next to the choice of the model, decisions on fit procedure and hyperparameters play a major role in the prediction performance, highlighting the importance of optimizing and reporting such choices. This work is a community effort to highlight strength and limitations of the field at representing dMRI acquired with trending encoding schemes, gaining insights into how different models generalize to different tissue types and fiber configurations over a large range of diffusion encodings.


Asunto(s)
Encéfalo/diagnóstico por imagen , Bases de Datos Factuales , Imagen de Difusión por Resonancia Magnética/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Redes Neurales de la Computación , Animales , Encéfalo/fisiología , Humanos , Ratones
2.
Neuroimage ; 243: 118502, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34433094

RESUMEN

White matter bundle segmentation using diffusion MRI fiber tractography has become the method of choice to identify white matter fiber pathways in vivo in human brains. However, like other analyses of complex data, there is considerable variability in segmentation protocols and techniques. This can result in different reconstructions of the same intended white matter pathways, which directly affects tractography results, quantification, and interpretation. In this study, we aim to evaluate and quantify the variability that arises from different protocols for bundle segmentation. Through an open call to users of fiber tractography, including anatomists, clinicians, and algorithm developers, 42 independent teams were given processed sets of human whole-brain streamlines and asked to segment 14 white matter fascicles on six subjects. In total, we received 57 different bundle segmentation protocols, which enabled detailed volume-based and streamline-based analyses of agreement and disagreement among protocols for each fiber pathway. Results show that even when given the exact same sets of underlying streamlines, the variability across protocols for bundle segmentation is greater than all other sources of variability in the virtual dissection process, including variability within protocols and variability across subjects. In order to foster the use of tractography bundle dissection in routine clinical settings, and as a fundamental analytical tool, future endeavors must aim to resolve and reduce this heterogeneity. Although external validation is needed to verify the anatomical accuracy of bundle dissections, reducing heterogeneity is a step towards reproducible research and may be achieved through the use of standard nomenclature and definitions of white matter bundles and well-chosen constraints and decisions in the dissection process.


Asunto(s)
Imagen de Difusión Tensora/métodos , Disección/métodos , Sustancia Blanca/diagnóstico por imagen , Algoritmos , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Vías Nerviosas/diagnóstico por imagen
3.
Magn Reson Med ; 86(6): 3304-3320, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34270123

RESUMEN

PURPOSE: Diffusion-weighted imaging allows investigators to identify structural, microstructural, and connectivity-based differences between subjects, but variability due to session and scanner biases is a challenge. METHODS: To investigate DWI variability, we present MASiVar, a multisite data set consisting of 319 diffusion scans acquired at 3 T from b = 1000 to 3000 s/mm2 across 14 healthy adults, 83 healthy children (5 to 8 years), three sites, and four scanners as a publicly available, preprocessed, and de-identified data set. With the adult data, we demonstrate the capacity of MASiVar to simultaneously quantify the intrasession, intersession, interscanner, and intersubject variability of four common DWI processing approaches: (1) a tensor signal representation, (2) a multi-compartment neurite orientation dispersion and density model, (3) white-matter bundle segmentation, and (4) structural connectomics. Respectively, we evaluate region-wise fractional anisotropy, mean diffusivity, and principal eigenvector; region-wise CSF volume fraction, intracellular volume fraction, and orientation dispersion index; bundle-wise shape, volume, fractional anisotropy, and length; and whole connectome correlation and maximized modularity, global efficiency, and characteristic path length. RESULTS: We plot the variability in these measures at each level and find that it consistently increases with intrasession to intersession to interscanner to intersubject effects across all processing approaches and that sometimes interscanner variability can approach intersubject variability. CONCLUSIONS: This study demonstrates the potential of MASiVar to more globally investigate DWI variability across multiple levels and processing approaches simultaneously and suggests harmonization between scanners for multisite analyses should be considered before inference of group differences on subjects.


Asunto(s)
Imagen de Difusión Tensora , Sustancia Blanca , Adulto , Anisotropía , Encéfalo/diagnóstico por imagen , Niño , Imagen de Difusión por Resonancia Magnética , Humanos , Neuritas
4.
Magn Reson Med ; 86(1): 456-470, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33533094

RESUMEN

PURPOSE: Diffusion weighted MRI imaging (DWI) is often subject to low signal-to-noise ratios (SNRs) and artifacts. Recent work has produced software tools that can correct individual problems, but these tools have not been combined with each other and with quality assurance (QA). A single integrated pipeline is proposed to perform DWI preprocessing with a spectrum of tools and produce an intuitive QA document. METHODS: The proposed pipeline, built around the FSL, MRTrix3, and ANTs software packages, performs DWI denoising; inter-scan intensity normalization; susceptibility-, eddy current-, and motion-induced artifact correction; and slice-wise signal drop-out imputation. To perform QA on the raw and preprocessed data and each preprocessing operation, the pipeline documents qualitative visualizations, quantitative plots, gradient verifications, and tensor goodness-of-fit and fractional anisotropy analyses. RESULTS: Raw DWI data were preprocessed and quality checked with the proposed pipeline and demonstrated improved SNRs; physiologic intensity ratios; corrected susceptibility-, eddy current-, and motion-induced artifacts; imputed signal-lost slices; and improved tensor fits. The pipeline identified incorrect gradient configurations and file-type conversion errors and was shown to be effective on externally available datasets. CONCLUSIONS: The proposed pipeline is a single integrated pipeline that combines established diffusion preprocessing tools from major MRI-focused software packages with intuitive QA.


Asunto(s)
Artefactos , Imagen de Difusión por Resonancia Magnética , Anisotropía , Encéfalo/diagnóstico por imagen , Imagen por Resonancia Magnética , Movimiento (Física)
5.
Neuroimage ; 221: 117128, 2020 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-32673745

RESUMEN

Cross-scanner and cross-protocol variability of diffusion magnetic resonance imaging (dMRI) data are known to be major obstacles in multi-site clinical studies since they limit the ability to aggregate dMRI data and derived measures. Computational algorithms that harmonize the data and minimize such variability are critical to reliably combine datasets acquired from different scanners and/or protocols, thus improving the statistical power and sensitivity of multi-site studies. Different computational approaches have been proposed to harmonize diffusion MRI data or remove scanner-specific differences. To date, these methods have mostly been developed for or evaluated on single b-value diffusion MRI data. In this work, we present the evaluation results of 19 algorithms that are developed to harmonize the cross-scanner and cross-protocol variability of multi-shell diffusion MRI using a benchmark database. The proposed algorithms rely on various signal representation approaches and computational tools, such as rotational invariant spherical harmonics, deep neural networks and hybrid biophysical and statistical approaches. The benchmark database consists of data acquired from the same subjects on two scanners with different maximum gradient strength (80 and 300 â€‹mT/m) and with two protocols. We evaluated the performance of these algorithms for mapping multi-shell diffusion MRI data across scanners and across protocols using several state-of-the-art imaging measures. The results show that data harmonization algorithms can reduce the cross-scanner and cross-protocol variabilities to a similar level as scan-rescan variability using the same scanner and protocol. In particular, the LinearRISH algorithm based on adaptive linear mapping of rotational invariant spherical harmonics features yields the lowest variability for our data in predicting the fractional anisotropy (FA), mean diffusivity (MD), mean kurtosis (MK) and the rotationally invariant spherical harmonic (RISH) features. But other algorithms, such as DIAMOND, SHResNet, DIQT, CMResNet show further improvement in harmonizing the return-to-origin probability (RTOP). The performance of different approaches provides useful guidelines on data harmonization in future multi-site studies.


Asunto(s)
Algoritmos , Encéfalo/diagnóstico por imagen , Aprendizaje Profundo , Imagen de Difusión por Resonancia Magnética/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Neuroimagen/métodos , Adulto , Imagen de Difusión por Resonancia Magnética/instrumentación , Imagen de Difusión por Resonancia Magnética/normas , Humanos , Procesamiento de Imagen Asistido por Computador/normas , Neuroimagen/instrumentación , Neuroimagen/normas , Análisis de Regresión
6.
J Magn Reson Imaging ; 51(1): 234-249, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31179595

RESUMEN

BACKGROUND: Fiber tracking with diffusion-weighted MRI has become an essential tool for estimating in vivo brain white matter architecture. Fiber tracking results are sensitive to the choice of processing method and tracking criteria. PURPOSE: To assess the variability for an algorithm in group studies reproducibility is of critical context. However, reproducibility does not assess the validity of the brain connections. Phantom studies provide concrete quantitative comparisons of methods relative to absolute ground truths, yet do no capture variabilities because of in vivo physiological factors. The ISMRM 2017 TraCED challenge was created to fulfill the gap. STUDY TYPE: A systematic review of algorithms and tract reproducibility studies. SUBJECTS: Single healthy volunteers. FIELD STRENGTH/SEQUENCE: 3.0T, two different scanners by the same manufacturer. The multishell acquisition included b-values of 1000, 2000, and 3000 s/mm2 with 20, 45, and 64 diffusion gradient directions per shell, respectively. ASSESSMENT: Nine international groups submitted 46 tractography algorithm entries each consisting 16 tracts per scan. The algorithms were assessed using intraclass correlation (ICC) and the Dice similarity measure. STATISTICAL TESTS: Containment analysis was performed to assess if the submitted algorithms had containment within tracts of larger volume submissions. This also serves the purpose to detect if spurious submissions had been made. RESULTS: The top five submissions had high ICC and Dice >0.88. Reproducibility was high within the top five submissions when assessed across sessions or across scanners: 0.87-0.97. Containment analysis shows that the top five submissions are contained within larger volume submissions. From the total of 16 tracts as an outcome relatively the number of tracts with high, moderate, and low reproducibility were 8, 4, and 4. DATA CONCLUSION: The different methods clearly result in fundamentally different tract structures at the more conservative specificity choices. Data and challenge infrastructure remain available for continued analysis and provide a platform for comparison. LEVEL OF EVIDENCE: 5 Technical Efficacy Stage: 1 J. Magn. Reson. Imaging 2020;51:234-249.


Asunto(s)
Encéfalo/anatomía & histología , Imagen de Difusión Tensora/métodos , Imagen de Difusión por Resonancia Magnética , Humanos , Valores de Referencia , Reproducibilidad de los Resultados
7.
Neuroimage ; 185: 1-11, 2019 01 15.
Artículo en Inglés | MEDLINE | ID: mdl-30317017

RESUMEN

Diffusion MRI fiber tractography is widely used to probe the structural connectivity of the brain, with a range of applications in both clinical and basic neuroscience. Despite widespread use, tractography has well-known pitfalls that limits the anatomical accuracy of this technique. Numerous modern methods have been developed to address these shortcomings through advances in acquisition, modeling, and computation. To test whether these advances improve tractography accuracy, we organized the 3-D Validation of Tractography with Experimental MRI (3D-VoTEM) challenge at the ISBI 2018 conference. We made available three unique independent tractography validation datasets - a physical phantom and two ex vivo brain specimens - resulting in 176 distinct submissions from 9 research groups. By comparing results over a wide range of fiber complexities and algorithmic strategies, this challenge provides a more comprehensive assessment of tractography's inherent limitations than has been reported previously. The central results were consistent across all sub-challenges in that, despite advances in tractography methods, the anatomical accuracy of tractography has not dramatically improved in recent years. Taken together, our results independently confirm findings from decades of tractography validation studies, demonstrate inherent limitations in reconstructing white matter pathways using diffusion MRI data alone, and highlight the need for alternative or combinatorial strategies to accurately map the fiber pathways of the brain.


Asunto(s)
Mapeo Encefálico/métodos , Encéfalo/anatomía & histología , Imagen de Difusión Tensora/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Vías Nerviosas/anatomía & histología , Humanos
8.
Magn Reson Med ; 80(4): 1666-1675, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-29411435

RESUMEN

PURPOSE: The bias and variance of high angular resolution diffusion imaging methods have not been thoroughly explored in the literature and may benefit from the simulation extrapolation (SIMEX) and bootstrap techniques to estimate bias and variance of high angular resolution diffusion imaging metrics. METHODS: The SIMEX approach is well established in the statistics literature and uses simulation of increasingly noisy data to extrapolate back to a hypothetical case with no noise. The bias of calculated metrics can then be computed by subtracting the SIMEX estimate from the original pointwise measurement. The SIMEX technique has been studied in the context of diffusion imaging to accurately capture the bias in fractional anisotropy measurements in DTI. Herein, we extend the application of SIMEX and bootstrap approaches to characterize bias and variance in metrics obtained from a Q-ball imaging reconstruction of high angular resolution diffusion imaging data. RESULTS: The results demonstrate that SIMEX and bootstrap approaches provide consistent estimates of the bias and variance of generalized fractional anisotropy, respectively. The RMSE for the generalized fractional anisotropy estimates shows a 7% decrease in white matter and an 8% decrease in gray matter when compared with the observed generalized fractional anisotropy estimates. On average, the bootstrap technique results in SD estimates that are approximately 97% of the true variation in white matter, and 86% in gray matter. CONCLUSION: Both SIMEX and bootstrap methods are flexible, estimate population characteristics based on single scans, and may be extended for bias and variance estimation on a variety of high angular resolution diffusion imaging metrics.


Asunto(s)
Encéfalo/diagnóstico por imagen , Imagen de Difusión Tensora/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Sesgo , Análisis por Conglomerados , Humanos , Modelos Estadísticos , Reproducibilidad de los Resultados
9.
J Digit Imaging ; 31(3): 304-314, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29725960

RESUMEN

High-throughput, large-scale medical image computing demands tight integration of high-performance computing (HPC) infrastructure for data storage, job distribution, and image processing. The Vanderbilt University Institute for Imaging Science (VUIIS) Center for Computational Imaging (CCI) has constructed a large-scale image storage and processing infrastructure that is composed of (1) a large-scale image database using the eXtensible Neuroimaging Archive Toolkit (XNAT), (2) a content-aware job scheduling platform using the Distributed Automation for XNAT pipeline automation tool (DAX), and (3) a wide variety of encapsulated image processing pipelines called "spiders." The VUIIS CCI medical image data storage and processing infrastructure have housed and processed nearly half-million medical image volumes with Vanderbilt Advanced Computing Center for Research and Education (ACCRE), which is the HPC facility at the Vanderbilt University. The initial deployment was natively deployed (i.e., direct installations on a bare-metal server) within the ACCRE hardware and software environments, which lead to issues of portability and sustainability. First, it could be laborious to deploy the entire VUIIS CCI medical image data storage and processing infrastructure to another HPC center with varying hardware infrastructure, library availability, and software permission policies. Second, the spiders were not developed in an isolated manner, which has led to software dependency issues during system upgrades or remote software installation. To address such issues, herein, we describe recent innovations using containerization techniques with XNAT/DAX which are used to isolate the VUIIS CCI medical image data storage and processing infrastructure from the underlying hardware and software environments. The newly presented XNAT/DAX solution has the following new features: (1) multi-level portability from system level to the application level, (2) flexible and dynamic software development and expansion, and (3) scalable spider deployment compatible with HPC clusters and local workstations.


Asunto(s)
Diagnóstico por Imagen/métodos , Procesamiento de Imagen Asistido por Computador/instrumentación , Procesamiento de Imagen Asistido por Computador/métodos , Sistemas de Información Radiológica/instrumentación , Humanos , Almacenamiento y Recuperación de la Información
10.
J Med Imaging (Bellingham) ; 11(1): 014005, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38188934

RESUMEN

Purpose: Diffusion-weighted magnetic resonance imaging (DW-MRI) is a critical imaging method for capturing and modeling tissue microarchitecture at a millimeter scale. A common practice to model the measured DW-MRI signal is via fiber orientation distribution function (fODF). This function is the essential first step for the downstream tractography and connectivity analyses. With recent advantages in data sharing, large-scale multisite DW-MRI datasets are being made available for multisite studies. However, measurement variabilities (e.g., inter- and intrasite variability, hardware performance, and sequence design) are inevitable during the acquisition of DW-MRI. Most existing model-based methods [e.g., constrained spherical deconvolution (CSD)] and learning-based methods (e.g., deep learning) do not explicitly consider such variabilities in fODF modeling, which consequently leads to inferior performance on multisite and/or longitudinal diffusion studies. Approach: In this paper, we propose a data-driven deep CSD method to explicitly constrain the scan-rescan variabilities for a more reproducible and robust estimation of brain microstructure from repeated DW-MRI scans. Specifically, the proposed method introduces a three-dimensional volumetric scanner-invariant regularization scheme during the fODF estimation. We study the Human Connectome Project (HCP) young adults test-retest group as well as the MASiVar dataset (with inter- and intrasite scan/rescan data). The Baltimore Longitudinal Study of Aging dataset is employed for external validation. Results: From the experimental results, the proposed data-driven framework outperforms the existing benchmarks in repeated fODF estimation. By introducing the contrastive loss with scan/rescan data, the proposed method achieved a higher consistency while maintaining higher angular correlation coefficients with the CSD modeling. The proposed method is assessing the downstream connectivity analysis and shows increased performance in distinguishing subjects with different biomarkers. Conclusion: We propose a deep CSD method to explicitly reduce the scan-rescan variabilities, so as to model a more reproducible and robust brain microstructure from repeated DW-MRI scans. The plug-and-play design of the proposed approach is potentially applicable to a wider range of data harmonization problems in neuroimaging.

11.
Med Image Anal ; 95: 103207, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38776843

RESUMEN

The lack of annotated datasets is a major bottleneck for training new task-specific supervised machine learning models, considering that manual annotation is extremely expensive and time-consuming. To address this problem, we present MONAI Label, a free and open-source framework that facilitates the development of applications based on artificial intelligence (AI) models that aim at reducing the time required to annotate radiology datasets. Through MONAI Label, researchers can develop AI annotation applications focusing on their domain of expertise. It allows researchers to readily deploy their apps as services, which can be made available to clinicians via their preferred user interface. Currently, MONAI Label readily supports locally installed (3D Slicer) and web-based (OHIF) frontends and offers two active learning strategies to facilitate and speed up the training of segmentation algorithms. MONAI Label allows researchers to make incremental improvements to their AI-based annotation application by making them available to other researchers and clinicians alike. Additionally, MONAI Label provides sample AI-based interactive and non-interactive labeling applications, that can be used directly off the shelf, as plug-and-play to any given dataset. Significant reduced annotation times using the interactive model can be observed on two public datasets.


Asunto(s)
Inteligencia Artificial , Imagenología Tridimensional , Humanos , Imagenología Tridimensional/métodos , Algoritmos , Programas Informáticos
12.
Artículo en Inglés | MEDLINE | ID: mdl-37228707

RESUMEN

Diffusion weighted magnetic resonance imaging (DW-MRI) captures tissue microarchitecture at millimeter scale. With recent advantages in data sharing, large-scale multi-site DW-MRI datasets are being made available for multi-site studies. However, DW-MRI suffers from measurement variability (e.g., inter- and intra-site variability, hardware performance, and sequence design), which consequently yields inferior performance on multi-site and/or longitudinal diffusion studies. In this study, we propose a novel, deep learning-based method to harmonize DW-MRI signals for a more reproducible and robust estimation of microstructure. Our method introduces a data-driven scanner-invariant regularization scheme to model a more robust fiber orientation distribution function (FODF) estimation. We study the Human Connectome Project (HCP) young adults test-retest group as well as the MASiVar dataset (with inter- and intra-site scan/rescan data). The 8th order spherical harmonics coefficients are employed as data representation. The results show that the proposed harmonization approach maintains higher angular correlation coefficients (ACC) with the ground truth signals (0.954 versus 0.942), while achieves higher consistency of FODF signals for intra-scanner data (0.891 versus 0.826), as compared with the baseline supervised deep learning scheme. Furthermore, the proposed data-driven framework is flexible and potentially applicable to a wider range of data harmonization problems in neuroimaging.

13.
Magn Reson Imaging ; 90: 1-16, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35341904

RESUMEN

Diffusion MRI (dMRI) is one of the most popular techniques for studying the brain structure, mainly the white matter region. Among several sampling methods in dMRI, the high angular resolution diffusion imaging (HARDI) technique has attracted researchers due to its more accurate fiber orientation estimation. However, the current single-shell HARDI makes the intravoxel structure challenging to estimate accurately. While multi-shell acquisition can address this problem, it takes a longer scanning time, restricting its use in clinical applications. In addition, most existing dMRI scanners with low gradient-strengths often acquire single-shell up to b=1000s/mm2 because of signal-to-noise ratio issues and severe image artefacts. Hence, we propose a novel generative adversarial network, VRfRNet, for the reconstruction of multi-shell multi-tissue fiber orientation distribution function from single-shell HARDI volumes. Such a transformation learning is performed in the spherical harmonics (SH) space, as raw input HARDI volume is transformed to SH coefficients to soften gradient directions. The proposed VRfRNet consists of several modules, such as multi-context feature enrichment module, feature level attention, and softmax level attention. In addition, three loss functions have been used to optimize network learning, including L1, adversarial, and total variation. The network is trained and tested using standard qualitative and quantitative performance metrics on the publicly available HCP data-set.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Sustancia Blanca , Algoritmos , Encéfalo/diagnóstico por imagen , Difusión , Imagen de Difusión por Resonancia Magnética/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Sustancia Blanca/diagnóstico por imagen
14.
IEEE Trans Med Imaging ; 40(10): 2534-2547, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-33373298

RESUMEN

Active learning is a unique abstraction of machine learning techniques where the model/algorithm could guide users for annotation of a set of data points that would be beneficial to the model, unlike passive machine learning. The primary advantage being that active learning frameworks select data points that can accelerate the learning process of a model and can reduce the amount of data needed to achieve full accuracy as compared to a model trained on a randomly acquired data set. Multiple frameworks for active learning combined with deep learning have been proposed, and the majority of them are dedicated to classification tasks. Herein, we explore active learning for the task of segmentation of medical imaging data sets. We investigate our proposed framework using two datasets: 1.) MRI scans of the hippocampus, 2.) CT scans of pancreas and tumors. This work presents a query-by-committee approach for active learning where a joint optimizer is used for the committee. At the same time, we propose three new strategies for active learning: 1.) increasing frequency of uncertain data to bias the training data set; 2.) Using mutual information among the input images as a regularizer for acquisition to ensure diversity in the training dataset; 3.) adaptation of Dice log-likelihood for Stein variational gradient descent (SVGD). The results indicate an improvement in terms of data reduction by achieving full accuracy while only using 22.69% and 48.85% of the available data for each dataset, respectively.


Asunto(s)
Imagen por Resonancia Magnética , Algoritmos , Procesamiento de Imagen Asistido por Computador , Tomografía Computarizada por Rayos X , Incertidumbre
15.
Med Image Anal ; 69: 101894, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33421919

RESUMEN

Deep learning for three dimensional (3D) abdominal organ segmentation on high-resolution computed tomography (CT) is a challenging topic, in part due to the limited memory provide by graphics processing units (GPU) and large number of parameters and in 3D fully convolutional networks (FCN). Two prevalent strategies, lower resolution with wider field of view and higher resolution with limited field of view, have been explored but have been presented with varying degrees of success. In this paper, we propose a novel patch-based network with random spatial initialization and statistical fusion on overlapping regions of interest (ROIs). We evaluate the proposed approach using three datasets consisting of 260 subjects with varying numbers of manual labels. Compared with the canonical "coarse-to-fine" baseline methods, the proposed method increases the performance on multi-organ segmentation from 0.799 to 0.856 in terms of mean DSC score (p-value < 0.01 with paired t-test). The effect of different numbers of patches is evaluated by increasing the depth of coverage (expected number of patches evaluated per voxel). In addition, our method outperforms other state-of-the-art methods in abdominal organ segmentation. In conclusion, the approach provides a memory-conservative framework to enable 3D segmentation on high-resolution CT. The approach is compatible with many base network structures, without substantially increasing the complexity during inference. Given a CT scan with at high resolution, a low-res section (left panel) is trained with multi-channel segmentation. The low-res part contains down-sampling and normalization in order to preserve the complete spatial information. Interpolation and random patch sampling (mid panel) is employed to collect patches. The high-dimensional probability maps are acquired (right panel) from integration of all patches on field of views.


Asunto(s)
Imagenología Tridimensional , Redes Neurales de la Computación , Abdomen/diagnóstico por imagen , Humanos , Procesamiento de Imagen Asistido por Computador , Tomografía Computarizada por Rayos X
16.
IEEE Trans Med Imaging ; 40(5): 1499-1507, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33560981

RESUMEN

Body part regression is a promising new technique that enables content navigation through self-supervised learning. Using this technique, the global quantitative spatial location for each axial view slice is obtained from computed tomography (CT). However, it is challenging to define a unified global coordinate system for body CT scans due to the large variabilities in image resolution, contrasts, sequences, and patient anatomy. Therefore, the widely used supervised learning approach cannot be easily deployed. To address these concerns, we propose an annotation-free method named blind-unsupervised-supervision network (BUSN). The contributions of the work are in four folds: (1) 1030 multi-center CT scans are used in developing BUSN without any manual annotation. (2) the proposed BUSN corrects the predictions from unsupervised learning and uses the corrected results as the new supervision; (3) to improve the consistency of predictions, we propose a novel neighbor message passing (NMP) scheme that is integrated with BUSN as a statistical learning based correction; and (4) we introduce a new pre-processing pipeline with inclusion of the BUSN, which is validated on 3D multi-organ segmentation. The proposed method is trained on 1,030 whole body CT scans (230,650 slices) from five datasets, as well as an independent external validation cohort with 100 scans. From the body part regression results, the proposed BUSN achieved significantly higher median R-squared score (=0.9089) than the state-of-the-art unsupervised method (=0.7153). When introducing BUSN as a preprocessing stage in volumetric segmentation, the proposed pre-processing pipeline using BUSN approach increases the total mean Dice score of the 3D abdominal multi-organ segmentation from 0.7991 to 0.8145.


Asunto(s)
Cuerpo Humano , Tomografía Computarizada por Rayos X , Humanos , Procesamiento de Imagen Asistido por Computador
17.
Magn Reson Imaging ; 76: 69-78, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33221421

RESUMEN

BACKGROUND: Achieving inter-site / inter-scanner reproducibility of diffusion weighted magnetic resonance imaging (DW-MRI) metrics has been challenging given differences in acquisition protocols, analysis models, and hardware factors. PURPOSE: Magnetic field gradients impart scanner-dependent spatial variations in the applied diffusion weighting that can be corrected if the gradient nonlinearities are known. However, retrieving manufacturer nonlinearity specifications is not well supported and may introduce errors in interpretation of units or coordinate systems. We propose an empirical approach to mapping the gradient nonlinearities with sequences that are supported across the major scanner vendors. STUDY TYPE: Prospective observational study. SUBJECTS: A spherical isotropic diffusion phantom, and a single human control volunteer. FIELD STRENGTH/SEQUENCE: 3 T (two scanners). Stejskal-Tanner spin echo sequence with b-values of 1000, 2000 s/mm2 with 12, 32, and 384 diffusion gradient directions per shell. ASSESSMENT: We compare the proposed correction with the prior approach using manufacturer specifications against typical diffusion pre-processing pipelines (i.e., ignoring spatial gradient nonlinearities). In phantom data, we evaluate metrics against the ground truth. In human and phantom data, we evaluate reproducibility across scans, sessions, and hardware. STATISTICAL TESTS: Wilcoxon rank-sum test between uncorrected and corrected data. RESULTS: In phantom data, our correction method reduces variation in mean diffusivity across sessions over uncorrected data (p < 0.05). In human data, we show that this method can also reduce variation in mean diffusivity across scanners (p < 0.05). CONCLUSION: Our method is relatively simple, fast, and can be applied retroactively. We advocate incorporating voxel-specific b-value and b-vector maps should be incorporated in DW-MRI harmonization preprocessing pipelines to improve quantitative accuracy of measured diffusion parameters.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Procesamiento de Imagen Asistido por Computador/métodos , Dinámicas no Lineales , Voluntarios Sanos , Humanos , Masculino , Fantasmas de Imagen , Reproducibilidad de los Resultados , Adulto Joven
18.
Artículo en Inglés | MEDLINE | ID: mdl-34531615

RESUMEN

Diffusion-weighted magnetic resonance imaging (DW-MRI) is the only non-invasive approach for estimation of intra-voxel tissue microarchitecture and reconstruction of in vivo neural pathways for the human brain. With improvement in accelerated MRI acquisition technologies, DW-MRI protocols that make use of multiple levels of diffusion sensitization have gained popularity. A well-known advanced method for reconstruction of white matter microstructure that uses multi-shell data is multi-tissue constrained spherical deconvolution (MT-CSD). MT-CSD substantially improves the resolution of intra-voxel structure over the traditional single shell version, constrained spherical deconvolution (CSD). Herein, we explore the possibility of using deep learning on single shell data (using the b=1000 s/mm2 from the Human Connectome Project (HCP)) to estimate the information content captured by 8th order MT-CSD using the full three shell data (b=1000, 2000, and 3000 s/mm2 from HCP). Briefly, we examine two network architectures: 1.) Sequential network of fully connected dense layers with a residual block in the middle (ResDNN), 2.) Patch based convolutional neural network with a residual block (ResCNN). For both networks an additional output block for estimation of voxel fraction was used with a modified loss function. Each approach was compared against the baseline of using MT-CSD on all data on 15 subjects from the HCP divided into 5 training, 2 validation, and 8 testing subjects with a total of 6.7 million voxels. The fiber orientation distribution function (fODF) can be recovered with high correlation (0.77 vs 0.74 and 0.65) and low root mean squared error ResCNN:0.0124, ResDNN:0.0168 and sCSD:0.0323 as compared to the ground truth of MT-CST, which was derived from the multi-shell DW-MRI acquisitions. The mean squared error between the MT-CSD estimates for white matter tissue fraction and for the predictions are ResCNN:0.0249 vs ResDNN:0.0264. We illustrate the applicability of high definition fiber tractography on a single testing subject with arcuate and corpus callosum Tractography. In summary, the proposed approach provides a promising framework to estimate MT-CSD with limited single shell data. Source code and models have been made publicly available.

19.
Lect Notes Monogr Ser ; 12446: 112-121, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-34456459

RESUMEN

Semi-supervised methods have an increasing impact on computer vision tasks to make use of scarce labels on large datasets, yet these approaches have not been well translated to medical imaging. Of particular interest, the MixMatch method achieves significant performance improvement over popular semi-supervised learning methods with scarce labels in the CIFAR-10 dataset. In a complementary approach, Nullspace Tuning on equivalence classes offers the potential to leverage multiple subject scans when the ground truth for the subject is unknown. This work is the first to (1) explore MixMatch with Nullspace Tuning in the context of medical imaging and (2) characterize the impacts of the methods with diminishing labels. We consider two distinct medical imaging domains: skin lesion diagnosis and lung cancer prediction. In both cases we evaluate models trained with diminishing labeled data using supervised, MixMatch, and Nullspace Tuning methods as well as MixMatch with Nullspace Tuning together. MixMatch with Nullspace Tuning together is able to achieve an AUC of 0.755 in lung cancer diagnosis with only 200 labeled subjects on the National Lung Screening Trial and a balanced multi-class accuracy of 77% with only 779 labeled examples on HAM10000. This performance is similar to that of the fully supervised methods when all labels are available. In advancing data driven methods in medical imaging, it is important to consider the use of current state-of-the-art semi-supervised learning methods from the greater machine learning community and their impact on the limitations of data acquisition and annotation.

20.
Magn Reson Imaging ; 58: 82-89, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30682379

RESUMEN

PURPOSE: The diffusion MRI "b-vector" table describing the diffusion sensitization direction can be flipped and permuted in dimension due to different orientation conventions used in scanners and incorrect or improperly utilized file formats. This can lead to incorrect fiber orientation estimates and subsequent tractography failure. Here, we present an automated quality control procedure to detect when the b-table is flipped and/or permuted incorrectly. METHODS: We define a "fiber coherence index" to describe how well fibers are connected to each other, and use it to automatically detect the correct configuration of b-vectors. We examined the performance on 3981 research subject scans (Baltimore Longitudinal Study of Aging), 1065 normal subject scans of high image quality (Human Connectome Project), and 202 patient scans (Vanderbilt University Medical Center), as well as 9 in-vivo and 9 ex-vivo animal data. RESULTS: The coherence index resulted in a 99.9% (3979/3981) and 100% (1065/1065) success rate in normal subject scans, 98% (198/202) in patient scans, and 100% (18/18) in both in-vivo and ex-vivo animal data in detecting the correct gradient table in datasets without severe image artifacts. The four failing cases (4/202) in patient scans, and two failures in healthy subject scans (2/3981), all showed prominent motion or signal dropout artifacts. CONCLUSIONS: The fiber coherence measure can be used as an automatic quality assurance check in any diffusion analysis pipeline. Additionally, the success of this fiber coherence measure suggests potential broader applications, including evaluating data quality, or even providing diagnostic value as a biomarker of white matter integrity.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Procesamiento de Imagen Asistido por Computador/métodos , Sustancia Blanca/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Envejecimiento , Animales , Biomarcadores , Encéfalo , Conectoma , Femenino , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Movimiento (Física) , Control de Calidad , Reproducibilidad de los Resultados , Saimiri , Programas Informáticos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA