Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
BMC Pregnancy Childbirth ; 21(1): 317, 2021 Apr 21.
Artículo en Inglés | MEDLINE | ID: mdl-33882864

RESUMEN

BACKGROUND: Obstetric haemorrhage is the leading cause of maternal death worldwide, 99% of which occur in low and middle income countries. The majority of deaths and adverse events are associated with delays in identifying compromise and escalating care. Management of severely compromised pregnant women may require transfer to tertiary centres for specialised treatment, therefore early recognition is vital for efficient management. The CRADLE vital signs alert device accurately measures blood pressure and heart rate, calculates the shock index (heart rate divided by systolic blood pressure) and alerts the user to compromise through a traffic light system reflecting previously validated shock index thresholds. METHODS: This is a planned secondary analysis of data from the CRADLE-3 trial from ten clusters across Africa, India and Haiti where the device and training package were randomly introduced. Referral data were prospectively collected for a 4-week period before, and a 4-week period 3 months after implementation. Referrals from primary or secondary care facilities to higher level care for any cause were recorded. The denominator was the number of women seen for maternity care in these facilities. RESULTS: Between April 1 2016 and Nov 30th, 2017 536,223 women attended maternity care facilities. Overall, 3.7% (n = 2784/74,828) of women seen in peripheral maternity facilities were referred to higher level care in the control period compared to 4.4% (n = 3212/73,371) in the intervention period (OR 0.89; 0.39-2.05) (data for nine sites that were able to collect denominator). Of these 0.29% (n = 212) pre-intervention and 0.16% (n = 120) post-intervention were referred to higher-level facilities for maternal haemorrhage. Although overall referrals did not significantly reduce there was a significant reduction in referrals for obstetric haemorrhage (OR 0.56 (0.39-0.65) following introduction of the device with homogeneity (i-squared 26.1) between sites. There was no increase in any bleeding-related morbidity (maternal death or emergency hysterectomy). CONCLUSIONS: Referrals for obstetric haemorrhage reduced following implementation of the CRADLE Vital Signs Alert Device, occurring without an increase in maternal death or emergency hysterectomy. This demonstrates the potential benefit of shock index in management pathways for obstetric haemorrhage and targeting limited resources in low- middle- income settings. TRIAL REGISTRATION: This study is registered with the ISRCTN registry, number ISRCTN41244132 (02/02/2016).


Asunto(s)
Vías Clínicas/organización & administración , Servicios de Salud Materna , Sistemas de Entrada de Órdenes Médicas/estadística & datos numéricos , Hemorragia Posparto , Derivación y Consulta/estadística & datos numéricos , Adulto , Países en Desarrollo , Diagnóstico Precoz , Femenino , Humanos , Servicios de Salud Materna/normas , Servicios de Salud Materna/estadística & datos numéricos , Mortalidad Materna , Evaluación de Procesos y Resultados en Atención de Salud , Hemorragia Posparto/diagnóstico , Hemorragia Posparto/mortalidad , Hemorragia Posparto/prevención & control , Embarazo , Tiempo de Tratamiento/normas , Tiempo de Tratamiento/estadística & datos numéricos , Signos Vitales
2.
Cochrane Database Syst Rev ; 8: CD012739, 2020 07 23.
Artículo en Inglés | MEDLINE | ID: mdl-32748394

RESUMEN

BACKGROUND: Regular blood pressure (BP) measurement is crucial for the diagnosis and management of hypertensive disorders in pregnancy, such as pre-eclampsia. BP can be measured in various settings, such as conventional clinics or self-measurement at home, and with different techniques, such as using auscultatory or automated BP devices. It is important to understand the impact of different settings and techniques of BP measurement on important outcomes for pregnant women. OBJECTIVES: To assess the effects of setting and technique of BP measurement for diagnosing hypertensive disorders in pregnancy on subsequent maternal and perinatal outcomes, women's quality of life, or use of health service resources. SEARCH METHODS: We searched Cochrane Pregnancy and Childbirth's Trials Register, ClinicalTrials.gov, the WHO International Clinical Trials Registry Platform (ICTRP) on 22 April 2020, and reference lists of retrieved studies. SELECTION CRITERIA: Randomised controlled trials (RCTs) involving pregnant women, using validated BP devices in different settings or using different techniques. DATA COLLECTION AND ANALYSIS: Two authors independently extracted data, assessed risk of bias, and used the GRADE approach to assess the certainty of the evidence. MAIN RESULTS: Of the 21 identified studies, we included three, and excluded 11; seven were ongoing. Of the three included RCTs (536,607 women), one was a cluster-RCT, with a substantially higher number of participants (536,233 deliveries) than the other two trials, but did not provide data for most of our outcomes. We generally judged the included studies at low risk of bias, however, the certainty of the evidence was low, due to indirectness and imprecision. Meta-analysis was not possible because each study investigated a different comparison. None of the included studies reported our primary outcome of systolic BP greater than or equal to 150 mmHg. None of the studies reported any of these important secondary outcomes: antenatal hospital admissions, neonatal unit length of stay, or neonatal endotracheal intubation and use of mechanical ventilation. Setting of BP measurement: self-measurement versus conventional clinic measurement (one study, 154 women) There were no maternal deaths in either the self-monitoring group or the usual care group. The study did not report perinatal mortality. Self-monitoring may lead to slightly more diagnoses of pre-eclampsia compared with usual care (risk ratio (RR) 1.49, 95% confidence interval (CI) 0.87 to 2.54; 154 women; 1 study; low-certainty evidence) but the wide 95% CI is consistent with possible benefit and possible harm. Self-monitoring may have little to no effect on the likelihood of induction of labour compared with usual care (RR 1.09, 95% CI 0.82 to 1.45; 154 women; 1 study; low-certainty evidence). We are uncertain if self-monitoring BP has any effect on maternal admission to intensive care (RR 1.54, 95% CI 0.06 to 37.25; 154 women; 1 study; low-certainty evidence), stillbirth (RR 2.57, 95% CI 0.13 to 52.63; 154 women; 1 study; low-certainty evidence), neonatal death (RR 1.54, 95% CI 0.06 to 37.25; 154 women; 1 study; low-certainty evidence) or preterm birth (RR 1.15, 95% CI 0.37 to 3.55; 154 women; 1 study; low-certainty evidence), compared with usual care because the certainty of evidence is low and the 95% CI is consistent with appreciable harms and appreciable benefits. Self-monitoring may lead to slightly more neonatal unit admissions compared with usual care (RR 1.53, 95% CI 0.65 to 3.62; 154 women; 1 study; low-certainty evidence) but the wide 95% CI includes the possibility of slightly fewer admissions with self-monitoring. Technique of BP measurement: Korotkoff phase IV (K4, muffling sound) versus Korotkoff phase V (K5, disappearance of sound) to represent diastolic BP (one study, 220 women) There were no maternal deaths in either the K4 or K5 group. There may be little to no difference in the diagnosis of pre-eclampsia between using K4 or K5 for diastolic BP (RR 1.16; 95% CI 0.89 to 1.49; 1 study; 220 women; low-certainty evidence), since the wide 95% CI includes the possibility of more diagnoses with K4. We are uncertain if there is a difference in perinatal mortality between the groups because the quality of evidence is low and the 95% CI is consistent with appreciable harm and appreciable benefit (RR 1.14, 95% CI 0.16 to 7.92; 1 study, 220 women; low-certainty evidence). The trial did not report data on maternal admission to intensive care, induction of labour, stillbirth, neonatal death, preterm birth, or neonatal unit admissions. Technique of BP measurement: CRADLE intervention (CRADLE device, a semi-automated BP monitor with additional features, and an education package) versus usual care (one study, 536,233 deliveries) There may be little to no difference between the use of the CRADLE device and usual care in the number of maternal deaths (adjusted RR 0.80, 95% CI 0.30 to 2.11; 536,233 women; 1 study; low-certainty evidence), but the 95% CI is consistent with appreciable harm and appreciable benefit. The trial did not report pre-eclampsia, induction of labour, perinatal mortality, preterm birth, or neonatal unit admissions. Maternal admission to intensive care and perinatal outcomes (stillbirths and neonatal deaths) were only collected for a small proportion of the women, identified by an outcome not by baseline characteristics, thereby breaking the random allocation. Therefore, any differences between the groups could not be attributed to the intervention, and we did not extract data for these outcomes. AUTHORS' CONCLUSIONS: The benefit, if any, of self-monitoring BP in hypertensive pregnancies remains uncertain, as the evidence is limited to one feasibility study. Current practice of using K5 to measure diastolic BP is supported for women with pregnancy hypertension. The benefit, if any, of using the CRADLE device to measure BP in pregnancy remains uncertain, due to the limitations and instability of the trial study design.


Asunto(s)
Determinación de la Presión Sanguínea/métodos , Complicaciones Cardiovasculares del Embarazo/diagnóstico , Monitoreo Ambulatorio de la Presión Arterial/métodos , Femenino , Humanos , Preeclampsia/diagnóstico , Preeclampsia/epidemiología , Embarazo , Complicaciones Cardiovasculares del Embarazo/epidemiología , Nacimiento Prematuro/epidemiología , Ensayos Clínicos Controlados Aleatorios como Asunto , Autocuidado/métodos
3.
PLoS Med ; 16(4): e1002783, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30978179

RESUMEN

BACKGROUND: Most pregnancy hypertension estimates in less-developed countries are from cross-sectional hospital surveys and are considered overestimates. We estimated population-based rates by standardised methods in 27 intervention clusters of the Community-Level Interventions for Pre-eclampsia (CLIP) cluster randomised trials. METHODS AND FINDINGS: CLIP-eligible pregnant women identified in their homes or local primary health centres (2013-2017). Included here are women who had delivered by trial end and received a visit from a community health worker trained to provide supplementary hypertension-oriented care, including standardised blood pressure (BP) measurement. Hypertension (BP ≥ 140/90 mm Hg) was defined as chronic (first detected at <20 weeks gestation) or gestational (≥20 weeks); pre-eclampsia was gestational hypertension plus proteinuria or a pre-eclampsia-defining complication. A multi-level regression model compared hypertension rates and types between countries (p < 0.05 considered significant). In 28,420 pregnancies studied, women were usually young (median age 23-28 years), parous (53.7%-77.3%), with singletons (≥97.5%), and enrolled at a median gestational age of 10.4 (India) to 25.9 weeks (Mozambique). Basic education varied (22.8% in Pakistan to 57.9% in India). Pregnancy hypertension incidence was lower in Pakistan (9.3%) than India (10.3%), Mozambique (10.9%), or Nigeria (10.2%) (p = 0.001). Most hypertension was diastolic only (46.4% in India, 72.7% in Pakistan, 61.3% in Mozambique, and 63.3% in Nigeria). At first presentation with elevated BP, gestational hypertension was most common diagnosis (particularly in Mozambique [8.4%] versus India [6.9%], Pakistan [6.5%], and Nigeria [7.1%]; p < 0.001), followed by pre-eclampsia (India [3.8%], Nigeria [3.0%], Pakistan [2.4%], and Mozambique [2.3%]; p < 0.001) and chronic hypertension (especially in Mozambique [2.5%] and Nigeria [2.8%], compared with India [1.2%] and Pakistan [1.5%]; p < 0.001). Inclusion of additional diagnoses of hypertension and related complications, from household surveys or facility record review (unavailable in Nigeria), revealed higher hypertension incidence: 14.0% in India, 11.6% in Pakistan, and 16.8% in Mozambique; eclampsia was rare (<0.5%). CONCLUSIONS: Pregnancy hypertension is common in less-developed settings. Most women in this study presented with gestational hypertension amenable to surveillance and timed delivery to improve outcomes. TRIAL REGISTRATION: This study is a secondary analysis of a clinical trial - ClinicalTrials.gov registration number NCT01911494.


Asunto(s)
Hipertensión Inducida en el Embarazo/epidemiología , Preeclampsia/epidemiología , Adulto , Estudios Transversales , Femenino , Humanos , Hipertensión/epidemiología , Incidencia , India/epidemiología , Mozambique/epidemiología , Nigeria/epidemiología , Pakistán/epidemiología , Embarazo , Complicaciones del Embarazo/epidemiología , Atención Prenatal , Adulto Joven
4.
Acta Obstet Gynecol Scand ; 98(9): 1178-1186, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31001814

RESUMEN

INTRODUCTION: Shock index (SI) is a predictor of hemodynamic compromise in obstetric patients. The SI threshold for action is not well understood. We aimed to evaluate SI thresholds as predictors of outcomes in obstetric patients. MATERIAL AND METHODS: We undertook a prospective cohort study at three South African hospitals of women with postpartum hemorrhage (n = 283) or maternal sepsis (n = 126). The "first" and "worst" SI following diagnosis were recorded. SI was compared with conventional vital signs as predictors of outcomes. The performance of SI <.9, SI .9-1.69 and SI ≥1.7 to predict outcomes (maternal death; Critical Care Unit admission; major procedure; hysterectomy) and hemorrhage-specific outcomes (lowest hemoglobin <70 g/l; blood transfusion ≥4 IU) were evaluated. RESULTS: "First" SI was one of two best performing vital signs for every outcome in postpartum hemorrhage and sepsis. In hemorrhage, risk of all outcomes increased with increasing "first" SI; for blood transfusion ≥4 IU odds ratio was 4.24 (95% confidence interval 1.25-14.36) for SI ≥1.7 vs SI .9-1.69. In sepsis, risk of all outcomes increased with increasing "worst" SI. Sensitivity, specificity, positive and negative predictive values of "first" SI <.9 vs SI ≥.9 for maternal death were 100.0%, 55.2%, 4.6% and 100.0%, respectively, in hemorrhage and 80.0%, 50.4%, 12.3% and 96.7%, respectively, in sepsis. CONCLUSIONS: The shock index was a consistent predictor of outcomes compared with conventional vital signs in postpartum hemorrhage and sepsis. SI <.9 performed well as a rule-out test and SI .9-1.69 and SI ≥1.7 indicated increased risk of all outcomes in both cohorts. These thresholds may alert to the need for urgent intervention and prevent maternal deaths.


Asunto(s)
Hemorragia Posparto , Sepsis/complicaciones , Choque/etiología , Adulto , Femenino , Hemodinámica , Humanos , Mortalidad Materna , Hemorragia Posparto/mortalidad , Valor Predictivo de las Pruebas , Embarazo , Estudios Prospectivos , Sepsis/mortalidad , Choque/mortalidad , Sudáfrica , Signos Vitales
5.
BMC Pregnancy Childbirth ; 18(1): 115, 2018 04 27.
Artículo en Inglés | MEDLINE | ID: mdl-29703254

RESUMEN

BACKGROUND: The CRADLE-3 trial is a stepped-wedge randomised controlled trial aiming to reduce maternal mortality and morbidity by implementing a novel vital sign device (CRADLE Vital Sign Alert) and training package into routine maternity care in 10 low-income sites. The MRC Guidance on complex interventions proposes that interventions and implementation strategies be shaped by early phase piloting and development work. We present the findings of a three-month mixed-methodology feasibility study for this trial, describe how this was informed by the MRC guidance and the study design was refined. METHODS: The fidelity, dose, feasibility and acceptability of implementation and training materials were assessed in three representative non-trial sites (Zimbabwe, Ethiopia, India) using multiple-choice questionnaires, evaluation of clinical management (action log), healthcare provider (HCP) semi-structured interviews and focus groups 4-10 weeks after implementation. Simultaneously, the 10 sites included in the main trial (eight countries) collected primary outcome data to inform the power calculation and randomisation allocation and assess the feasibility of data collection. RESULTS: The package was implemented with high fidelity (85% of HCP trained, n = 204). The questionnaires indicated a good understanding of device use with 75% of participants scoring > 75% (n = 97; 90% of those distributed). Action logs were inconsistently completed but indicated that the majority of HCP responded appropriately to abnormal results. From 18 HCP interviews and two focus groups it was widely reported that the intervention improved capacity to make clinical decisions, escalate care and make appropriate referrals. Nine of the ten main trial sites achieved ethical approval for pilot data collection. Intensive care was an inconsistent marker of morbidity and stroke an infrequent outcome and therefore they were removed from the main trial composite outcome. Tools and methods of data collection were optimized and event rates used to inform randomisation. CONCLUSIONS: This feasibility study demonstrates that the components of the intervention were acceptable, methods of implementing were successful and the main trial design would be feasible. Qualitative work identified key moderators that informed the main trial process evaluation. Changes to the training package, implementation strategy, study design and processes were identified to refine the implementation in the main trial. TRIAL REGISTRATION: ISRCTN41244132 ; Registered 24/11/2015.


Asunto(s)
Técnicas de Diagnóstico Obstétrico y Ginecológico/instrumentación , Personal de Salud/psicología , Implementación de Plan de Salud , Muerte Materna/prevención & control , Ensayos Clínicos Controlados Aleatorios como Asunto , Sistemas de Apoyo a Decisiones Clínicas , Etiopía , Estudios de Factibilidad , Femenino , Grupos Focales , Recursos en Salud , Humanos , India , Monitoreo Fisiológico , Embarazo , Investigación Cualitativa , Derivación y Consulta , Proyectos de Investigación , Encuestas y Cuestionarios , Signos Vitales , Zimbabwe
6.
Reprod Health ; 15(Suppl 1): 92, 2018 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-29945641

RESUMEN

Approximately 820 women die in pregnancy and childbirth every day worldwide, with 99% of these occurring in low-resource settings. The most common causes of maternal mortality are haemorrhage, sepsis and hypertensive disorders. There are established, effective solutions to these complications, however challenges remain in identifying who is at greatest risk and ensuring that interventions are delivered early when they have the greatest potential to benefit. Measuring vital signs is the first step in identifying women at risk. Overstretched or poorly trained staff and inadequate access to accurate, reliable equipment to measure vital signs can potentially result in delayed treatment initiation. Early warning systems may help alert users to identify patients at risk, especially where novel technologies can improve usability by automating calculations and alerting users to abnormalities. This may be of greatest benefit in under-resourced settings where task-sharing is common and early identification of complications can allow for prioritisation of life-saving interventions. This paper highlights the challenges of accurate vital sign measurement in pregnancy and identifies innovations which may improve detection of pregnancy complications.


Asunto(s)
Diseño de Equipo , Hipertensión/diagnóstico , Monitoreo Fisiológico/instrumentación , Complicaciones del Embarazo/diagnóstico , Medición de Riesgo/métodos , Choque/diagnóstico , Signos Vitales , Difusión de Innovaciones , Equipos y Suministros , Femenino , Humanos , Hipertensión Inducida en el Embarazo , Mortalidad Materna , Embarazo , Atención Primaria de Salud
7.
Reprod Health ; 15(1): 5, 2018 Jan 05.
Artículo en Inglés | MEDLINE | ID: mdl-29304812

RESUMEN

BACKGROUND: Vital signs measurement can identify pregnant and postpartum women who require urgent treatment or referral. In low-resource settings, healthcare workers have limited access to accurate vital signs measuring devices suitable for their environment and training. The CRADLE Vital Signs Alert (VSA) is a novel device measuring blood pressure and pulse that is accurate in pregnancy and designed for low-resource settings. Its traffic light early warning system alerts healthcare workers to the need for escalation of care for women with hypertension, haemorrhage or sepsis. This study evaluated the usability and acceptability of the CRADLE VSA device. METHODS: Evaluation was conducted in community and primary care settings in India, Mozambique and Nigeria and tertiary hospitals in South Africa. Purposeful sampling was used to convene 155 interviews and six focus groups with healthcare workers using the device (n = 205) and pregnant women and their family members (n = 41). Interviews and focus groups were conducted in the local language and audio-recorded, transcribed and translated into English for analysis. Thematic analysis was undertaken using an a priori thematic framework, as well as an inductive approach. RESULTS: Most healthcare workers perceived the CRADLE device to be easy to use and accurate. The traffic lights early warning system was unanimously reported positively, giving healthcare workers confidence with decision-making and a sense of professionalism. However, a minority in South Africa described manual inflation as tiring, particularly when measuring vital signs in obese and hypertensive women (n = 4) and a few South African healthcare workers distrusted the device's accuracy (n = 7). Unanimously, pregnant women liked the CRADLE device. The traffic light early warning system gave women and their families a better understanding of the importance of vital signs in pregnancy and during the postpartum period. CONCLUSION: The CRADLE device was well accepted by healthcare workers from a range of countries and levels of facility, including those with no previous vital signs measurement experience. The device motivated women to attend primary care and encouraged them to accept treatment and referral.


Asunto(s)
Equipos y Suministros/economía , Servicios de Salud Materna , Monitoreo Fisiológico/instrumentación , Complicaciones del Embarazo/diagnóstico , Signos Vitales , Adulto , Servicios de Salud Comunitaria , Agentes Comunitarios de Salud , Diagnóstico Precoz , Diseño de Equipo/economía , Estudios de Factibilidad , Femenino , Humanos , India , Servicios de Salud Materna/economía , Monitoreo Fisiológico/economía , Mozambique , Nigeria , Áreas de Pobreza , Embarazo , Atención Primaria de Salud/economía , Atención Primaria de Salud/métodos , Investigación Cualitativa , Sudáfrica , Recursos Humanos
8.
Lancet Glob Health ; 9(8): e1119-e1128, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34237265

RESUMEN

BACKGROUND: Blood pressure measurement is a marker of antenatal care quality. In well resourced settings, lower blood pressure cutoffs for hypertension are associated with adverse pregnancy outcomes. We aimed to study the associations between blood pressure thresholds and adverse outcomes and the diagnostic test properties of these blood pressure cutoffs in low-resource settings. METHODS: We did a secondary analysis of data from 22 intervention clusters in the Community-Level Interventions for Pre-eclampsia (CLIP) cluster randomised trials (NCT01911494) in India (n=6), Mozambique (n=6), and Pakistan (n=10). We included pregnant women aged 15-49 years (12-49 years in Mozambique), identified in their community by trained community health workers, who had data on blood pressure measurements and outcomes. The trial was unmasked. Maximum blood pressure was categorised as: normal blood pressure (systolic blood pressure [sBP] <120 mm Hg and diastolic blood pressure [dBP] <80 mm Hg), elevated blood pressure (sBP 120-129 mm Hg and dBP <80 mm Hg), stage 1 hypertension (sBP 130-139 mm Hg or dBP 80-89 mm Hg, or both), non-severe stage 2 hypertension (sBP 140-159 mm Hg or dBP 90-109 mm Hg, or both), or severe stage 2 hypertension (sBP ≥160 mm Hg or dBP ≥110 mm Hg, or both). We classified women according to the maximum blood pressure category reached across all visits for the primary analyses. The primary outcome was a maternal, fetal, or neonatal mortality or morbidity composite. We estimated dose-response relationships between blood pressure category and adverse outcomes, as well as diagnostic test properties. FINDINGS: Between Nov 1, 2014, and Feb 28, 2017, 21 069 women (6067 in India, 4163 in Mozambique, and 10 839 in Pakistan) contributed 103 679 blood pressure measurements across the three CLIP trials. Only women with non-severe or severe stage 2 hypertension, as discrete diagnostic categories, experienced more adverse outcomes than women with normal blood pressure (risk ratios 1·29-5·88). Using blood pressure categories as diagnostic thresholds (women with blood pressure within the category or any higher category vs those with blood pressure in any lower category), dose-response relationships were observed between increasing thresholds and adverse outcomes, but likelihood ratios were informative only for severe stage 2 hypertension and maternal CNS events (likelihood ratio 6·36 [95% CI 3·65-11·07]) and perinatal death (5·07 [3·64-7·07]), particularly stillbirth (8·53 [5·63-12·92]). INTERPRETATION: In low-resource settings, neither elevated blood pressure nor stage 1 hypertension were associated with maternal, fetal, or neonatal mortality or morbidity adverse composite outcomes. Only the threshold for severe stage 2 hypertension met diagnostic test performance standards. Current diagnostic thresholds for hypertension in pregnancy should be retained. FUNDING: University of British Columbia, the Bill & Melinda Gates Foundation.


Asunto(s)
Presión Sanguínea/fisiología , Preeclampsia/epidemiología , Embarazo/fisiología , Adolescente , Adulto , Niño , Servicios de Salud Comunitaria , Femenino , Humanos , India/epidemiología , Persona de Mediana Edad , Mozambique/epidemiología , Pakistán/epidemiología , Valores de Referencia , Medición de Riesgo/métodos , Adulto Joven
9.
Pregnancy Hypertens ; 25: 179-184, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34175582

RESUMEN

OBJECTIVES: To evaluate community-based health workers' ability to identify cases of hypertension in pregnancy, safely deliver methyldopa and magnesium sulphate and make referrals when appropriate. STUDY DESIGN: This was part of Nigeria Community-Level Interventions for Pre-eclampsia (CLIP) cluster randomized controlled trial (NCT01911494). Community-based Health Workers (CHW) recruited pregnant women from five Local Government Areas (clusters) and used mobile health aid for clinical assessment of pre-eclampsia. MAIN OUTCOME MEASURES: The primary outcome was the number of adverse events that occurred after the administration of magnesium sulphate and/or methyldopa to pregnant women by CHWs. FINDINGS: Of 8790 women receiving mobile health-guided care, community-based health workers in Nigeria provided 309 women with hypertension (4.2% of delivered women), and safely administered 142 doses of intramuscular magnesium sulphate. Community Heath Extension Workers (CHEWs) and nurses gave fifty-two and sixty-seven doses of intramuscular magnesium sulphate respectively, twenty-three doses were given by other health care workers (midwives, community health officers, health assistants). The high rate of administration by nurses can be explained by turf protection as well as their seniority within the health system. Also, CHEWs and nurses gave 124 doses of oral methyldopa and 126 urgent referrals were completed. There were no complications related to administration of treatment or referral. INTERPRETATION: These findings demonstrate the ability of community-based health workers to safely administer methyldopa and intramuscular magnesium sulphate. The use of task-sharing, therefore, could drastically reduce the three delays (triage, transport and treatment) associated with high maternal mortality and morbidity in rural communities in low- and middle-income countries.


Asunto(s)
Antihipertensivos/uso terapéutico , Competencia Clínica , Servicios de Salud Comunitaria/normas , Preeclampsia/prevención & control , Adolescente , Adulto , Antihipertensivos/administración & dosificación , Benchmarking , Femenino , Humanos , Sulfato de Magnesio/administración & dosificación , Sulfato de Magnesio/uso terapéutico , Metildopa/efectos adversos , Metildopa/uso terapéutico , Persona de Mediana Edad , Nigeria , Embarazo , Adulto Joven
11.
Pregnancy Hypertens ; 22: 109-118, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32777710

RESUMEN

OBJECTIVES: To reduce all-cause maternal and perinatal mortality and major morbidity through Lady Health Worker (LHW)-facilitated community engagement and early diagnosis, stabilization and referral of women with preeclampsia, an important contributor to adverse maternal and perinatal outcomes given delays in early detection and initial management. STUDY DESIGN: In the Pakistan Community-Level Interventions for Pre-eclampsia (CLIP) cluster randomized controlled trial (NCT01911494), LHWs engaged the community, recruited pregnant women from 20 union councils (clusters), undertook mobile health-guided clinical assessment for preeclampsia, and referral to facilities after stabilization. MAIN OUTCOME MEASURES: The primary outcome was a composite of maternal, fetal and newborn mortality and major morbidity. FINDINGS: We recruited 39,446 women in intervention (N = 20,264) and control clusters (N = 19,182) with minimal loss to follow-up (3∙7% vs. 4∙5%, respectively). The primary outcome did not differ between intervention (26·6%) and control (21·9%) clusters (adjusted odds ratio, aOR, 1∙20 [95% confidence interval 0∙84-1∙72]; p = 0∙31). There was reduction in stillbirths (0·89 [0·81-0·99]; p = 0·03), but no impact on maternal death (1·08 [0·69, 1·71]; p = 0·74) or morbidity (1·12 [0·57, 2·16]; p = 0·77); early (0·95 [0·82-1·09]; p = 0·46) or late neonatal deaths (1·23 [0·97-1·55]; p = 0·09); or neonatal morbidity (1·22 [0·77, 1·96]; p = 0·40). Improvements in outcome rates were observed with 4-7 (p = 0·015) and ≥8 (p < 0·001) (vs. 0) CLIP contacts. INTERPRETATION: The CLIP intervention was well accepted by the community and implemented by LHWs. Lack of effects on adverse outcomes could relate to quality care for mothers with pre-eclampsia in health facilities. Future strategies for community outreach must also be accompanied by health facility strengthening. FUNDING: The University of British Columbia (PRE-EMPT), a grantee of the Bill & Melinda Gates Foundation (OPP1017337).


Asunto(s)
Agentes Comunitarios de Salud/organización & administración , Preeclampsia/terapia , Resultado del Embarazo/epidemiología , Atención Prenatal/estadística & datos numéricos , Adulto , Análisis por Conglomerados , Femenino , Humanos , Lactante , Recién Nacido , Mortalidad Materna , Pakistán , Embarazo , Adulto Joven
12.
Pregnancy Hypertens ; 21: 166-175, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32554291

RESUMEN

OBJECTIVES: Pregnancy hypertension is associated with 7.1% of maternal deaths in India. The objective of this trial was to assess whether task-sharing care might reduce adverse pregnancy outcomes related to delays in triage, transport, and treatment. STUDY DESIGN: The Indian Community-Level Interventions for Pre-eclampsia (CLIP) open-label cluster randomised controlled trial (NCT01911494) recruited pregnant women in 12 clusters (initial four-cluster internal pilot) in Belagavi and Bagalkote, Karnataka. The CLIP intervention (6 clusters) consisted of community engagement, community health workers (CHW) provided mobile health (mHeath)-guided clinical assessment, initial treatment, and referral to facility either urgently (<4 h) or non-urgently (<24 h), dependent on algorithm-defined risk. Treatment effect was estimated by multi-level logistic regression modelling, adjusted for prognostically-significant baseline variables. Predefined secondary analyses included safety and evaluation of the intensity of mHealth-guided CHW-provided contacts. MAIN OUTCOME MEASURES: 20% reduction in composite of maternal, fetal, and newborn mortality and major morbidity. RESULTS: All 14,783 recruited pregnancies (7839 intervention, 6944 control) were followed-up. The primary outcome did not differ between intervention and control arms (adjusted odds ratio (aOR) 0.92 [95% confidence interval 0.74, 1.15]; p = 0.47; intraclass correlation coefficient 0.013). There were no intervention-related safety concerns following administration of either methyldopa or MgSO4, and 401 facility referrals. Compared with intervention arm women without CLIP contacts, those with ≥8 contacts suffered fewer stillbirths (aOR 0.19 [0.10, 0.35]; p < 0.001), at the probable expense of survivable neonatal morbidity (aOR 1.39 [0.97, 1.99]; p = 0.072). CONCLUSIONS: As implemented, solely community-level interventions focussed on pre-eclampsia did not improve outcomes in northwest Karnataka.


Asunto(s)
Servicios de Salud Comunitaria/organización & administración , Preeclampsia/terapia , Resultado del Embarazo/epidemiología , Adolescente , Adulto , Femenino , Humanos , India/epidemiología , Recién Nacido , Persona de Mediana Edad , Preeclampsia/mortalidad , Embarazo , Adulto Joven
13.
Pregnancy Hypertens ; 21: 96-105, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32464527

RESUMEN

OBJECTIVES: Pregnancy hypertension is the third leading cause of maternal mortality in Mozambique and contributes significantly to fetal and neonatal mortality. The objective of this trial was to assess whether task-sharing care might reduce adverse pregnancy outcomes related to delays in triage, transport, and treatment. STUDY DESIGN: The Mozambique Community-Level Interventions for Pre-eclampsia (CLIP) cluster randomised controlled trial (NCT01911494) recruited pregnant women in 12 administrative posts (clusters) in Maputo and Gaza Provinces. The CLIP intervention (6 clusters) consisted of community engagement, community health worker-provided mobile health-guided clinical assessment, initial treatment, and referral to facility either urgently (<4hrs) or non-urgently (<24hrs), dependent on algorithm-defined risk. Treatment effect was estimated by multi-level logistic regression modelling, adjusted for prognostically-significant baseline variables. Predefined secondary analyses included safety and evaluation of the intensity of CLIP contacts. MAIN OUTCOME MEASURES: 20% reduction in composite of maternal, fetal, and newborn mortality and major morbidity. RESULTS: 15,013 women (15,123 pregnancies) were recruited in intervention (N = 7930; 2·0% loss to follow-up (LTFU)) and control (N = 7190; 2·8% LTFU) clusters. The primary outcome did not differ between intervention and control clusters (adjusted odds ratio (aOR) 1·31, 95% confidence interval (CI) [0·70, 2·48]; p = 0·40). Compared with intervention arm women without CLIP contacts, those with ≥8 contacts experienced fewer primary outcomes (aOR 0·79 (95% CI 0·63, 0·99); p = 0·041), primarily due to improved maternal outcomes (aOR 0·72 (95% CI 0·53, 0·97); p = 0·033). INTERPRETATION: As generally implemented, the CLIP intervention did not improve pregnancy outcomes; community implementation of the WHO eight contact model may be beneficial. FUNDING: The University of British Columbia (PRE-EMPT), a grantee of the Bill & Melinda Gates Foundation (OPP1017337).


Asunto(s)
Servicios de Salud Comunitaria/organización & administración , Preeclampsia/terapia , Atención Prenatal/organización & administración , Análisis por Conglomerados , Femenino , Humanos , Mortalidad Materna , Mozambique/epidemiología , Mortalidad Perinatal , Preeclampsia/mortalidad , Embarazo
14.
Lancet Glob Health ; 7(3): e347-e356, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30784635

RESUMEN

BACKGROUND: In 2015, an estimated 303 000 women died in pregnancy and childbirth. Obstetric haemorrhage, sepsis, and hypertensive disorders of pregnancy account for more than 50% of maternal deaths worldwide. There are effective treatments for these pregnancy complications, but they require early detection by measurement of vital signs and timely administration to save lives. The primary aim of this trial was to determine whether implementation of the CRADLE Vital Sign Alert and an education package into community and facility maternity care in low-resource settings could reduce a composite of all-cause maternal mortality or major morbidity (eclampsia and hysterectomy). METHODS: We did a pragmatic, stepped-wedge, cluster-randomised controlled trial in ten clusters across Africa, India, and Haiti, introducing the device into routine maternity care. Each cluster contained at least one secondary or tertiary hospital and their main referral facilities. Clusters crossed over from existing routine care to the CRADLE intervention in one of nine steps at 2-monthly intervals, with CRADLE devices replacing existing equipment at the randomly allocated timepoint. A computer-generated randomly allocated sequence determined the order in which the clusters received the intervention. Because of the nature of the intervention, this trial was not masked. Data were gathered monthly, with 20 time periods of 1 month. The primary composite outcome was at least one of eclampsia, emergency hysterectomy, and maternal death. This study is registered with the ISRCTN registry, number ISRCTN41244132. FINDINGS: Between April 1, 2016, and Nov 30, 2017, among 536 223 deliveries, the primary outcome occurred in 4067 women, with 998 maternal deaths, 2692 eclampsia cases, and 681 hysterectomies. There was an 8% decrease in the primary outcome from 79·4 per 10 000 deliveries pre-intervention to 72·8 per 10 000 deliveries post-intervention (odds ratio [OR] 0·92, 95% CI 0·86-0·97; p=0·0056). After planned adjustments for variation in event rates between and within clusters over time, the unexpected degree of variability meant we were unable to judge the benefit or harms of the intervention (OR 1·22, 95% CI 0·73-2·06; p=0·45). INTERPRETATION: There was an absolute 8% reduction in primary outcome during the trial, with no change in resources or staffing, but this reduction could not be directly attributed to the intervention due to variability. We encountered unanticipated methodological challenges with this trial design, which can provide valuable learning for future research and inform the trial design of future international stepped-wedge trials. FUNDING: Newton Fund Global Research Programme: UK Medical Research Council; Department of Biotechnology, Ministry of Science & Technology, Government of India; and UK Department of International Development.


Asunto(s)
Determinación de la Presión Sanguínea/instrumentación , Eclampsia/epidemiología , Personal de Salud/educación , Determinación de la Frecuencia Cardíaca/instrumentación , Histerectomía/estadística & datos numéricos , Mortalidad Materna , Complicaciones del Embarazo/diagnóstico , África/epidemiología , Determinación de la Presión Sanguínea/métodos , Diagnóstico Precoz , Intervención Médica Temprana , Femenino , Haití/epidemiología , Recursos en Salud , Determinación de la Frecuencia Cardíaca/métodos , Humanos , Hipertensión Inducida en el Embarazo/diagnóstico , Hipertensión Inducida en el Embarazo/terapia , India/epidemiología , Servicios de Salud Materna , Hemorragia Posparto/diagnóstico , Hemorragia Posparto/terapia , Embarazo , Complicaciones del Embarazo/terapia , Complicaciones Infecciosas del Embarazo/diagnóstico , Complicaciones Infecciosas del Embarazo/terapia , Sepsis/diagnóstico , Sepsis/terapia , Signos Vitales
15.
Hypertension ; 74(5): 1144-1151, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31564161

RESUMEN

Preeclampsia is a common cause of acute kidney injury (AKI) in low- and middle-income countries, but AKI incidence in preeclampsia, its risk factors, and renal outcomes are unknown. A prospective observational multicenter study of women admitted with preeclampsia in South Africa was conducted. Creatinine concentrations were extracted from national laboratory databases for women with maximum creatinine of ≥90 µmol/L (≥1.02 mg/dL). Renal injury and recovery were defined by Kidney Disease Improving Global Outcomes creatinine criteria. Predefined risk factors, maternal outcomes, and neonatal outcomes were compared between AKI stages. Of 1547 women admitted with preeclampsia 237 (15.3%) met AKI criteria: 6.9% (n=107) stage 1, 4.3% (n=67) stage 2, and 4.1% (n=63) stage 3. There was a higher risk of maternal death (n=7; relative risk, 4.3; 95% CI, 1.6-11.4) and stillbirth (n=80; relative risk, 2.2; 95% CI, 1.8-2.8) in women with AKI compared with those without. Perinatal mortality was also increased (89 of 240; 37.1%). Hypertension in a previous pregnancy was the strongest predictor of AKI stage 2 or 3 (odds ratio, 2.24; 95% CI, 1.21-4.17). Renal recovery rate reduced with increasing AKI stage. A third of surviving women (76 of 230 [33.0%]) had not recovered baseline renal function by discharge. Approximately half (39 of 76; 51.3%) of these women had no further creatinine testing post-discharge. In summary, AKI was common in women with preeclampsia and had high rates of associated maternal and perinatal mortality. Only two-thirds of women had confirmed renal recovery. History of a previous hypertensive pregnancy was an important risk factor.


Asunto(s)
Lesión Renal Aguda/epidemiología , Muerte Materna/tendencias , Muerte Perinatal , Preeclampsia/epidemiología , Mortinato/epidemiología , Lesión Renal Aguda/diagnóstico , Lesión Renal Aguda/terapia , Adolescente , Adulto , Comorbilidad , Intervalos de Confianza , Creatinina/sangre , Países en Desarrollo , Femenino , Estudios de Seguimiento , Hospitalización/estadística & datos numéricos , Humanos , Recién Nacido , Pruebas de Función Renal , Oportunidad Relativa , Pobreza , Preeclampsia/diagnóstico , Preeclampsia/terapia , Embarazo , Prevalencia , Estudios Prospectivos , Medición de Riesgo , Índice de Severidad de la Enfermedad , Sudáfrica , Análisis de Supervivencia
16.
Pregnancy Hypertens ; 12: 183-188, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29175171

RESUMEN

OBJECTIVES: To evaluate the association between blood pressure (BP) measurements and adverse outcomes in women with pre-eclampsia. STUDY DESIGN: A prospective cohort study of women with pre-eclampsia admitted to three South African tertiary facilities. BP was measured using the CRADLE Vital Signs Alert (VSA), incorporated with a traffic light early warning system; green: systolic BP <140 mmHg and diastolic BP <90 mmHg, yellow: systolic BP 140-159 and/or diastolic BP 90-109 mmHg (but neither is above the upper threshold), red: systolic BP ≥160 mmHg and/or diastolic BP ≥110 mmHg. MAIN OUTCOME MEASURES: Maternal: death, eclampsia, stroke, kidney injury; process measures: magnesium sulfate use, Critical Care Unit (CCU) admission; perinatal: stillbirth, neonatal death, preterm delivery. RESULTS: Of 1547 women with pre-eclampsia (including 42 twin pregnancies), 33.0% of women triggered a red light on admission and 78.6% at their highest BP. Severe hypertension and adverse outcomes were common across yellow and red categories. Comparing admission red to yellow lights, there was a significant increase in kidney injury (OR 1.74, CI 1.31-2.33, trend test p = .003), magnesium sulfate use (OR 3.40, CI 2.24-5.18, p < .001) and CCU admission (OR 1.50, CI 1.18-1.91, p < .001), but not for maternal death, eclampsia, extended perinatal death or preterm delivery. CONCLUSION: The CRADLE VSA, with integrated traffic light early warning system, can identify women who are hypertensive, at increased risk of severe pre-eclampsia complications and in need of escalation of care. Women who triggered a red light were at increased risk of kidney injury, magnesium sulfate use and CCU admission.


Asunto(s)
Determinación de la Presión Sanguínea/instrumentación , Presión Sanguínea , Alarmas Clínicas , Preeclampsia/diagnóstico , Adulto , Determinación de la Presión Sanguínea/métodos , Progresión de la Enfermedad , Diagnóstico Precoz , Femenino , Humanos , Modelos Logísticos , Muerte Materna , Oportunidad Relativa , Muerte Perinatal , Preeclampsia/mortalidad , Preeclampsia/fisiopatología , Preeclampsia/terapia , Valor Predictivo de las Pruebas , Embarazo , Pronóstico , Estudios Prospectivos , Medición de Riesgo , Factores de Riesgo , Sudáfrica , Centros de Atención Terciaria , Factores de Tiempo , Adulto Joven
17.
J Glob Health ; 8(2): 020401, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30140431

RESUMEN

BACKGROUND: Hypertensive disorders of pregnancy contribute to 14% of all maternal deaths, the majority of which occur in low- and middle-income countries. The aim of the study was to describe the maternal and perinatal clinical outcomes of women with pre-eclampsia living in middle- and low-income countries. METHODS: The study was a prospective observational study of women with pre-eclampsia (n = 1547, 42 twin pregnancies) at three South African tertiary facilities. Using stepwise logistic regression model area under the receiver operating characteristic curve (AUROC) values, the association between maternal baseline and admission characteristics and risk of adverse outcomes was evaluated. Main outcome measures were eclampsia, kidney injury and perinatal death. RESULTS: In 1547 women with pre-eclampsia, 16 (1%) died, 147 (9.5%) had eclampsia, four (0.3%) had a stroke and 272 (17.6%) had kidney injury. Of the 1589 births, there were 332 (21.0%) perinatal deaths; of these, 281 (84.5%) were stillbirths. Of 1308 live births, 913 (70.0%) delivered <37 completed weeks and 544 (41.7%) delivered <34 weeks' gestation. Young maternal age (AUROC = 0.76, 95% confidence interval (CI) = 0.71-0.80) and low Body Mass Index BMI (AUROC 0.65, 95% CI = 0.59-0.69) were significant predictors of eclampsia. Highest systolic blood pressure had the strongest association with kidney injury, (AUROC = 0.64, 95% CI = 0.60-0.68). Early gestation at admission was most strongly associated with perinatal death (AUROC = 0.81, 95% CI = 0.77-0.84). CONCLUSIONS: The incidence of pre-eclampsia complications, perinatal death and preterm delivery in women referred to tertiary care in South Africa was much higher than reported in other low- and middle-income studies and despite access to tertiary care interventions. Teenage mothers and those with low BMI were at highest risk of eclampsia. This information could be used to inform guidelines, the research agenda and policy.


Asunto(s)
Lesión Renal Aguda/epidemiología , Eclampsia/epidemiología , Muerte Perinatal , Preeclampsia/terapia , Adolescente , Adulto , Índice de Masa Corporal , Femenino , Humanos , Recién Nacido , Edad Materna , Embarazo , Resultado del Embarazo , Estudios Prospectivos , Factores de Riesgo , Sudáfrica/epidemiología , Atención Terciaria de Salud , Adulto Joven
18.
Trials ; 19(1): 206, 2018 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-29587875

RESUMEN

BACKGROUND: Obstetric haemorrhage, sepsis and pregnancy hypertension account for more than 50% of maternal deaths worldwide. Early detection and effective management of these conditions relies on vital signs. The Microlife® CRADLE Vital Sign Alert (VSA) is an easy-to-use, accurate device that measures blood pressure and pulse. It incorporates a traffic-light early warning system that alerts all levels of healthcare provider to the need for escalation of care in women with obstetric haemorrhage, sepsis or pregnancy hypertension, thereby aiding early recognition of haemodynamic instability and preventing maternal mortality and morbidity. The aim of the trial was to determine whether implementation of the CRADLE intervention (the Microlife® CRADLE VSA device and CRADLE training package) into routine maternity care in place of existing equipment will reduce a composite outcome of maternal mortality and morbidity in low- and middle-income country populations. METHODS: The CRADLE-3 trial was a stepped-wedge cluster-randomised controlled trial of the CRADLE intervention compared to routine maternity care. Each cluster crossed from routine maternity care to the intervention at 2-monthly intervals over the course of 20 months (April 2016 to November 2017). All women identified as pregnant or within 6 weeks postpartum, presenting for maternity care in cluster catchment areas were eligible to participate. Primary outcome data (composite of maternal death, eclampsia and emergency hysterectomy per 10,000 deliveries) were collected at 10 clusters (Gokak, Belgaum, India; Harare, Zimbabwe; Ndola, Zambia; Lusaka, Zambia; Free Town, Sierra Leone; Mbale, Uganda; Kampala, Uganda; Cap Haitien, Haiti; South West, Malawi; Addis Ababa, Ethiopia). This trial was informed by the Medical Research Council guidance for complex interventions. A process evaluation was undertaken to evaluate implementation in each site and a cost-effectiveness evaluation will be undertaken. DISCUSSION: All aspects of this protocol have been evaluated in a feasibility study, with subsequent optimisation of the intervention. This trial will demonstrate the potential impact of the CRADLE intervention on reducing maternal mortality and morbidity in low-resource settings. It is anticipated that the relatively low cost of the intervention and ease of integration into existing health systems will be of significant interest to local, national and international health policy-makers. TRIAL REGISTRATION: ISCRTN41244132. Registered on 2 February 2016. Prospective protocol modifications have been recorded and were communicated to the Ethics Committees and Trials Committees. The adapted Standard Protocol Items: Recommendations for Interventional Trials (SPIRIT) Checklist and the SPIRIT Checklist are attached as Additional file 1.


Asunto(s)
Determinación de la Presión Sanguínea/instrumentación , Presión Sanguínea , Alarmas Clínicas , Países en Desarrollo , Hipertensión Inducida en el Embarazo/diagnóstico , Choque Cardiogénico/diagnóstico , África , Determinación de la Presión Sanguínea/economía , Alarmas Clínicas/economía , Análisis Costo-Beneficio , Países en Desarrollo/economía , Diseño de Equipo , Femenino , Haití , Costos de la Atención en Salud , Humanos , Hipertensión Inducida en el Embarazo/mortalidad , Hipertensión Inducida en el Embarazo/fisiopatología , Hipertensión Inducida en el Embarazo/terapia , India , Mortalidad Materna , Estudios Multicéntricos como Asunto , Ensayos Clínicos Pragmáticos como Asunto , Valor Predictivo de las Pruebas , Embarazo , Factores de Riesgo , Choque Cardiogénico/mortalidad , Choque Cardiogénico/fisiopatología , Choque Cardiogénico/terapia , Resultado del Tratamiento
19.
BMJ Innov ; 4(4): 192-198, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30319784

RESUMEN

OBJECTIVES: Haemorrhage, hypertension, sepsis and abortion complications (often from haemorrhage or sepsis) contribute to 60% of all maternal deaths. Each is associated with vital signs (blood pressure (BP) and pulse) abnormalities, and the majority of deaths are preventable through simple and timely intervention. This paper presents the development and evaluation of the CRADLE Vital Signs Alert (VSA), an accurate, low-cost and easy-to-use device measuring BP and pulse with an integrated traffic light early warning system. The VSA was designed to be used by all cadres of healthcare providers for pregnant women in low-resource settings with the aim to prevent avoidable maternal mortality and morbidity. METHODS: The development and the mixed-methods clinical evaluation of the VSA are described. RESULTS: Preliminary fieldwork identified that introduction of BP devices to rural clinics improved antenatal surveillance of BP in pregnant women. The aesthetics of the integrated traffic light system were developed through iterative qualitative evaluation. The traffic lights trigger according to evidence-based vital sign thresholds in hypertension and haemodynamic compromise from haemorrhage and sepsis. The VSA can be reliably used as an auscultatory device, as well as its primary semiautomated function, and is suitable as a self-monitor used by pregnant women. CONCLUSION: The VSA is an accurate device incorporating an evidence-based traffic light early warning system. It is designed to ensure suitability for healthcare providers with limited training and may improve care for women in pregnancy, childbirth and in the postnatal period.

20.
Obstet Med ; 10(3): 113-119, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-29051778

RESUMEN

Reverse innovation, defined as the flow of ideas from low- to high-income settings, is gaining traction in healthcare. With an increasing focus on value, investing in low-cost but effective and innovative solutions can be of mutual benefit to both high- and low-income countries. Reverse innovation has a role in addressing maternal health challenges in high-income countries by harnessing these innovative solutions for vulnerable populations especially in rural and remote regions. In this paper, we present three examples of 'reverse innovation' for maternal health: a low-cost, easy-to-use blood pressure device (CRADLE), a diagnostic algorithm (mini PIERS) and accompanying mobile app (PIERS on the Move), and a novel method for mapping maternal outcomes (MOM).

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA