Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
BMC Res Notes ; 11(1): 818, 2018 Nov 16.
Artículo en Inglés | MEDLINE | ID: mdl-30446000

RESUMEN

OBJECTIVE: Dried blood spots (DBS) offer multiple benefits for collecting, storing and shipping whole blood samples. Our objective was to compare, for the first time in Africa, the performance of DBS with respect to plasma in the detection of Hepatitis B surface antigen (HBsAg) and antibodies to Hepatitis C Virus (anti-HCV) using Architect, Abbott Diagnostics. RESULTS: DBS had a sensitivity of 99%, a specificity of 100%, a positive predictive value of 99%, a negative predictive value of 100% and a kappa index of 0.99 for the detection of HBsAg. For anti-HCV detection, the sensitivity, specificity, positive predictive value, negative predictive value and kappa index were 99%, 98%, 98%, 99%, and 0.97, respectively. This study confirms that DBS may be a reliable alternative specimen type for HBV and HCV diagnosis.


Asunto(s)
Pruebas con Sangre Seca , Antígenos de Superficie de la Hepatitis B/sangre , Hepatitis B/diagnóstico , Anticuerpos contra la Hepatitis C/sangre , Hepatitis C/diagnóstico , Camerún/epidemiología , Estudios Transversales , Anticuerpos contra la Hepatitis B/sangre , Virus de la Hepatitis B , Antígenos de la Hepatitis C/sangre , Humanos , Sensibilidad y Especificidad
2.
J Virol Methods ; 243: 158-163, 2017 05.
Artículo en Inglés | MEDLINE | ID: mdl-28219762

RESUMEN

According to the WHO/UNAIDS recommendations, an acceptable HIV rapid diagnostic tests (RDTs) has to perform a sensitivity≥99% and a specificity≥98%. Given the constant release of new RDTs for HIV testing in the market and the high HIV genetic diversity in Cameroon, it is interesting to monitor their performances in that setting. A total of 240 HIV positive (including 219 HIV-1 M, 15 HIV-1 O, 1 HIV-1 N, 1 HIV-1 M/O recombinant and 4 HIV-2) and 240 HIV negative plasma samples were used to evaluate twelve routinely used RDTs in Cameroon. A reference algorithm combining Enzyme Immunoassays and nucleic acid testing was used as gold standard. The sensitivity, specificity, positive predictive value, and negative predictive value of the twelve RDTs evaluated varied between 93.7 and 100%; 95.8 and 100%; 96.0 and 100%, and 94.1 and 100%, respectively. Five out of the twelve RDTs could not detect some HIV-1 O variants, one of them failed to detect an HIV-2 variant while all them efficiently detected HIV-1 N and HIV M/O recombinant. Our findings underscore the need to monitor the performances of RDTs to be used for HIV testing in Cameroon using locally obtained well-characterized samples panels.


Asunto(s)
Pruebas Diagnósticas de Rutina/métodos , Infecciones por VIH/diagnóstico , Camerún , Humanos , Tamizaje Masivo/métodos , Plasma/virología , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA