Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Clin Sleep Med ; 13(2): 283-290, 2017 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-27784415

RESUMEN

STUDY OBJECTIVES: Autotitrating continuous positive airway pressure (CPAP) devices adjust pressure in response to changes in airflow and are an alternative to attended in-laboratory titration polysomnography (PSG) to determine optimal pressure levels. The aim of this study was to compare the performance of the System One RemStar Auto A-Flex (Philips Respironics, Murrysville, PA, USA) automatically adjusted positive airway pressure (APAP) mode to manually titrated, fixed pressure CPAP and to validate the device's breathing event detection capabilities against attended in-laboratory PSG. METHODS: Sixty-one patients investigated in five centers for moderate to severe obstructive sleep apnea between May 2012 and June 2013 were invited to participate. Participants underwent two full-night attended polysomnograms in random order with manually titrated, fixed pressure CPAP versus APAP. RESULTS: Fifty-three participants with a mean apnea-hypopnea index (AHI) of 45.9 ± 23 completed two sleep studies and were included in the analysis. There were significant but not clinically relevant differences between APAP and CPAP respectively: Apnea index [1.0 (2.8 ± 0.8), median (mean ± standard deviation)] versus [1.8 (5.3 ± 11.5)], p = 0.004; percentage of N1 sleep [12.3 (15.9 ± 0.5)] versus [14.3 (18.9 ± 12.7)], p = 0.028. AHI values differed between PSG [2.8 (5.5. ± 9.3)] and device [3.7 (6.0 ± 8.6)], p = 0.003). Regarding residual events detection, intraclass correlation coefficients for AHI were strong (0.956, p < 0.001) and the area under the curve was 0.988 (AHI cut-off value of 10). CONCLUSIONS: The new APAP modality was effective and residual apnea-hypopnea indices calculated by the device strongly correlated to those assessed by PSG. COMMENTARY: A commentary on this article appears in this issue on page 167.


Asunto(s)
Presión de las Vías Aéreas Positiva Contínua/instrumentación , Presión de las Vías Aéreas Positiva Contínua/métodos , Apnea Obstructiva del Sueño/terapia , Apnea/fisiopatología , Estudios Cruzados , Método Doble Ciego , Europa (Continente) , Femenino , Humanos , Masculino , Persona de Mediana Edad , Polisomnografía , Reproducibilidad de los Resultados , Apnea Obstructiva del Sueño/fisiopatología
2.
ESC Heart Fail ; 3(3): 212-219, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28834663

RESUMEN

AIMS: At least 50% of patients with heart failure (HF) may have sleep-disordered breathing (SDB). Overnight in-hospital polysomnography (PSG) is considered the gold standard for diagnosis, but a lack of access to such testing contributes to under-diagnosis of SDB. Therefore, there is a need for simple and reliable validated methods to aid diagnosis in patients with HF. The aim of this study was to investigate the accuracy of a non-contact type IV screening device, SleepMinderTM (SM), compared with in-hospital PSG for detecting SDB in patients with HF. METHODS AND RESULTS: The study included 75 adult patients with systolic HF and suspected SDB who underwent simultaneous PSG and SM recordings. An algorithm was developed from the SM signals, using digital signal processing and pattern recognition techniques to calculate the SM apnoea-hypopnoea index (AHI). This was then compared with expert-scored PSGAHI . The SM algorithm had 70% sensitivity and 89% specificity for identifying patients with clinically significant SDB (AHI ≥ 15/h). At this threshold, it had a positive likelihood ratio of 6.3 and a negative likelihood ratio of 0.16. The overall accuracy of the SMAHI algorithm was 85.8% as shown by the area under a receiver operator characteristic curve. The mean AHI with SM was 3.8/h (95% confidence interval 0.5-7.1) lower than that with PSG. CONCLUSIONS: The accuracy of the non-contact type IV screening device SM is good for clinically significant SDB in patients with systolic HF and could be considered as a simple first step in the diagnostic pathway.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA