Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Br J Nutr ; 130(9): 1521-1536, 2023 11 14.
Artículo en Inglés | MEDLINE | ID: mdl-36847278

RESUMEN

Only 6 to 8 % of the UK adults meet the daily recommendation for dietary fibre. Fava bean processing lead to vast amounts of high-fibre by-products such as hulls. Bean hull fortified bread was formulated to increase and diversify dietary fibre while reducing waste. This study assessed the bean hull: suitability as a source of dietary fibre; the systemic and microbial metabolism of its components and postprandial events following bean hull bread rolls. Nine healthy participants (53·9 ± 16·7 years) were recruited for a randomised controlled crossover study attending two 3 days intervention sessions, involving the consumption of two bread rolls per day (control or bean hull rolls). Blood and faecal samples were collected before and after each session and analysed for systemic and microbial metabolites of bread roll components using targeted LC-MS/MS and GC analysis. Satiety, gut hormones, glucose, insulin and gastric emptying biomarkers were also measured. Two bean hull rolls provided over 85 % of the daily recommendation for dietary fibre; but despite being a rich source of plant metabolites (P = 0·04 v. control bread), these had poor systemic bioavailability. Consumption of bean hull rolls for 3 days significantly increased plasma concentration of indole-3-propionic acid (P = 0·009) and decreased faecal concentration of putrescine (P = 0·035) and deoxycholic acid (P = 0·046). However, it had no effect on postprandial plasma gut hormones, bacterial composition and faecal short chain fatty acids amount. Therefore, bean hulls require further processing to improve their bioactives systemic availability and fibre fermentation.


Asunto(s)
Fabaceae , Hormonas Gastrointestinales , Adulto , Humanos , Voluntarios Sanos , Putrescina , Pan/análisis , Cromatografía Liquida , Estudios Cruzados , Espectrometría de Masas en Tándem , Fibras de la Dieta/análisis , Fabaceae/metabolismo , Ácido Desoxicólico , Glucemia/análisis
2.
BMC Pregnancy Childbirth ; 23(1): 13, 2023 Jan 09.
Artículo en Inglés | MEDLINE | ID: mdl-36624440

RESUMEN

AIM: This study aimed to evaluate the effects of using the teach-back method among women with limited maternal health literacy (LMHL) on maternal health literacy(MHL), postpartum health behaviours and maternal-infant health outcomes. METHODS: A randomized controlled study was conducted in the obstetrics department of Anhui Provincial Hospital, China. A total of 258 pregnant women with LMHL were recruited at the point of admission to the hospital for birth and randomly assigned to the control group (n = 130), where women received routine education sessions, and the teach-back group (n = 128), where women received routine education sessions plus a teach-back intervention. The two groups were assessed in terms of MHL before and after the intervention, breastfeeding execution, uptake of 42-day postpartum check-ups, complete uptake of one-time recommended vaccines, and physical health outcomes. Statistical tests were employed for data analysis. RESULTS: There was no significant difference between the two groups in terms of MHL and other social, demographic, and medical status at baseline. After the intervention, the teach-back group had a higher level of MHL (p < 0.001), better postpartum health behaviours in terms of exclusive breastfeeding within 24 hours postpartum (x2 = 22.853, p<0.001), exclusive breastfeeding within 42 days postpartum (x2 = 47.735, p<0.001), uptake of 42-day postpartum check-ups (x2 = 9.050, p = 0.003) and vaccination (x2 = 5.586, p = 0.018) and better maternal-infant health outcomes in terms of the incidence of subinvolution of the uterus (x2 = 6.499, p = 0.011), acute mastitis (x2 = 4.884, p = 0.027), postpartum constipation (x2 = 5.986, p = 0.014), overweight (x2 = 4.531, p = 0.033) and diaper dermatitis (x2 = 10.896, p = 0.001). CONCLUSIONS: This study shows that the teach-back method is effective for enhancing MHL, leading to positive postpartum health behaviours, and improving postpartum maternal-infant health outcomes among women with LMHL. The teach-back method may play an important role in improving postpartum maternal-infant health and could be considered in maternal health education. TRIAL REGISTRATION NUMBER: Our trial has been prospectively registered at ClinicalTrials.gov (Ref. No.: NCT04858945) and the enrollment date was 26/04/2021.


Asunto(s)
Alfabetización en Salud , Lactante , Embarazo , Femenino , Humanos , Salud del Lactante , Periodo Posparto , Sobrepeso , Lactancia Materna
3.
Eur Radiol ; 32(8): 5179-5188, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35175380

RESUMEN

OBJECTIVES: To explore downstream management and outcomes of machine learning (ML)-based CT derived fractional flow reserve (FFRCT) strategy compared with an anatomical coronary computed tomography angiography (CCTA) alone assessment in participants with intermediate coronary artery stenosis. METHODS: In this prospective study conducted from April 2018 to March 2019, participants were assigned to either the CCTA or FFRCT group. The primary endpoint was the rate of invasive coronary angiography (ICA) that demonstrated non-obstructive disease at 90 days. Secondary endpoints included coronary revascularization and major adverse cardiovascular events (MACE) at 1-year follow-up. RESULTS: In total, 567 participants were allocated to the CCTA group and 566 to the FFRCT group. At 90 days, the rate of ICA without obstructive disease was higher in the CCTA group (33.3%, 39/117) than that (19.8%, 19/96) in the FFRCT group (risk difference [RD] = 13.5%, 95% confidence interval [CI]: 8.4%, 18.6%; p = 0.03). The ICA referral rate was higher in the CCTA group (27.5%, 156/567) than in the FFRCT group (20.3%, 115/566) (RD = 7.2%, 95% CI: 2.3%, 12.1%; p = 0.003). The revascularization-to-ICA ratio was lower in the CCTA group than that in the FFRCT group (RD = 19.8%, 95% CI: 14.1%, 25.5%, p = 0.002). MACE was more common in the CCTA group than that in the FFRCT group at 1 year (HR: 1.73; 95% CI: 1.01, 2.95; p = 0.04). CONCLUSION: In patients with intermediate stenosis, the FFRCT strategy appears to be associated with a lower rate of referral for ICA, ICA without obstructive disease, and 1-year MACE when compared to the anatomical CCTA alone strategy. KEY POINTS: • In stable patients with intermediate stenosis, ML-based FFRCT strategy was associated with a lower referral ICA rate, a lower normalcy rate of ICA, and higher revascularization-to-ICA ratio than the CCTA strategy. • Compared with the CCTA strategy, ML-based FFRCTshows superior outcome prediction value which appears to be associated with a lower rate of 1-year MACE. • ML-based FFRCT strategy as a non-invasive "one-stop-shop" modality may be the potential to change diagnostic workflows in patients with suspected coronary artery disease.


Asunto(s)
Angiografía por Tomografía Computarizada , Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Angiografía por Tomografía Computarizada/métodos , Constricción Patológica , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Estenosis Coronaria/diagnóstico por imagen , Humanos , Aprendizaje Automático , Valor Predictivo de las Pruebas , Estudios Prospectivos , Tomografía Computarizada por Rayos X
4.
Eur Radiol ; 31(3): 1482-1493, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32929641

RESUMEN

OBJECTIVE: To investigate the effect of coronary calcification morphology and severity on the diagnostic performance of machine learning (ML)-based coronary CT angiography (CCTA)-derived fractional flow reserve (CT-FFR) with FFR as a reference standard. METHODS: A total of 442 patients (61.2 ± 9.1 years, 70% men) with 544 vessels who underwent CCTA, ML-based CT-FFR, and invasive FFR from China multicenter CT-FFR study were enrolled. The effect of calcification arc, calcification remodeling index (CRI), and Agatston score (AS) on the diagnostic performance of CT-FFR was investigated. CT-FFR ≤ 0.80 and lumen reduction ≥ 50% determined by CCTA were identified as vessel-specific ischemia with invasive FFR as a reference standard. RESULTS: Compared with invasive FFR, ML-based CT-FFR yielded an overall sensitivity of 0.84, specificity of 0.94, and accuracy of 0.90 in a total of 344 calcification lesions. There was no statistical difference in diagnostic accuracy, sensitivity, or specificity of CT-FFR across different calcification arc, CRI, or AS levels. CT-FFR exhibited improved discrimination of ischemia compared with CCTA alone in lesions with mild-to-moderate calcification (AUC, 0.89 vs. 0.69, p < 0.001) and lesions with CRI ≥ 1 (AUC, 0.89 vs. 0.71, p < 0.001). The diagnostic accuracy and specificity of CT-FFR were higher than CCTA alone in patients and vessels with mid (100 to 299) or high (≥ 300) AS. CONCLUSION: Coronary calcification morphology and severity did not influence diagnostic performance of CT-FFR in ischemia detection, and CT-FFR showed marked improved discrimination of ischemia compared with CCTA alone in the setting of calcification. KEY POINTS: • CT-FFR provides superior diagnostic performance than CCTA alone regardless of coronary calcification. • No significant differences in the diagnostic performance of CT-FFR were observed in coronary arteries with different coronary calcification arcs and calcified remodeling indexes. • No significant differences in the diagnostic accuracy of CT-FFR were observed in coronary arteries with different coronary calcification score levels.


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , China , Angiografía por Tomografía Computarizada , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Femenino , Humanos , Aprendizaje Automático , Masculino , Valor Predictivo de las Pruebas , Índice de Severidad de la Enfermedad , Tomografía Computarizada por Rayos X
5.
Radiology ; 296(2): E15-E25, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32083985

RESUMEN

In December 2019, an outbreak of severe acute respiratory syndrome coronavirus 2 infection occurred in Wuhan, Hubei Province, China, and spread across China and beyond. On February 12, 2020, the World Health Organization officially named the disease caused by the novel coronavirus as coronavirus disease 2019 (COVID-19). Because most patients infected with COVID-19 had pneumonia and characteristic CT imaging patterns, radiologic examinations have become vital in early diagnosis and the assessment of disease course. To date, CT findings have been recommended as major evidence for clinical diagnosis of COVID-19 in Hubei, China. This review focuses on the etiology, epidemiology, and clinical symptoms of COVID-19 while highlighting the role of chest CT in prevention and disease control.


Asunto(s)
Betacoronavirus , Infecciones por Coronavirus/diagnóstico por imagen , Neumonía Viral/diagnóstico por imagen , COVID-19 , Prueba de COVID-19 , China/epidemiología , Técnicas de Laboratorio Clínico/métodos , Infecciones por Coronavirus/diagnóstico , Infecciones por Coronavirus/epidemiología , Infecciones por Coronavirus/transmisión , Diagnóstico Diferencial , Diagnóstico Precoz , Humanos , Pandemias , Neumonía Viral/epidemiología , Neumonía Viral/transmisión , SARS-CoV-2 , Índice de Severidad de la Enfermedad , Tomografía Computarizada por Rayos X
6.
Eur Radiol ; 30(5): 2525-2534, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-32006167

RESUMEN

OBJECTIVE: To investigate the effect of image quality of coronary CT angiography (CCTA) on the diagnostic performance of a machine learning-based CT-derived fractional flow reserve (FFRCT). METHODS: This nationwide retrospective study enrolled participants from 10 individual centers across China. FFRCT analysis was performed in 570 vessels in 437 patients. Invasive FFR and FFRCT values ≤ 0.80 were considered ischemia-specific. Four-score subjective assessment based on image quality and objective measurement of vessel enhancement was performed on a per-vessel basis. The effects of body mass index (BMI), sex, heart rate, and coronary calcium score on the diagnostic performance of FFRCT were studied. RESULTS: Among 570 vessels, 216 were considered ischemia-specific by invasive FFR and 198 by FFRCT. Sensitivity and specificity of FFRCT for detecting lesion-specific ischemia were 0.82 and 0.93, respectively. Area under the curve (AUC) of high-quality images (0.93, n = 159) was found to be superior to low-quality images (0.80, n = 92, p = 0.02). Objective image quality and heart rate were also associated with diagnostic performance of FFRCT, whereas there was no statistical difference in diagnostic performance among different BMI, sex, and calcium score groups (all p > 0.05, Bonferroni correction). CONCLUSIONS: This retrospective multicenter study supported the FFRCT as a noninvasive test in evaluating lesion-specific ischemia. Subjective image quality, vessel enhancement, and heart rate affect the diagnostic performance of FFRCT. KEY POINTS: • FFRCTcan be used to evaluate lesion-specific ischemia. • Poor image quality negatively affects the diagnostic performance of FFRCT. • CCTA with ≥ score 3, intracoronary enhancement degree of 300-400 HU, and heart rate below 70 bpm at scanning could be of great benefit to more accurate FFRCTanalysis.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico , Reserva del Flujo Fraccional Miocárdico/fisiología , Aprendizaje Automático , Anciano , Estenosis Coronaria/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos
7.
Radiology ; 285(3): 941-952, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28654338

RESUMEN

Purpose To assess the accuracy of computed tomographic (CT) angiography for diagnosis of cerebral aneurysms 5 mm or smaller, with digital subtraction angiography (DSA) as the reference standard, in a large patient cohort Materials and Methods This retrospective study was approved by the local institutional review board with a waiver of written informed consent. A total of 1366 patients who underwent cerebral CT angiography followed by DSA were included. The performance of CT angiography for depiction of aneurysms was evaluated by two readers on a per-patient and per-aneurysm basis and based on size of aneurysm, location, and status of rupture. The performance of CT angiography for diagnosis of aneurysms of different size, location, and rupture status was compared by using χ2 test. κ statistic was used to assess interreader agreement for diagnosis of aneurysms. Results Of 1366 patients, 579 patients had 711 small aneurysms at DSA. By using DSA as the reference standard, the respective sensitivity, specificity, and accuracy of CT angiography for readers 1 and 2 for detection of small aneurysms on a per-patient basis were 97.1% (562 of 579) and 97.4% (564 of 579), 98.5% (451 of 458) and 99.1% (454 of 458), and 97.7% (1013 of 1037) and 98.2% (1018 of 1037) and those on a per-aneurysm basis were 95.2% (677 of 711) and 95.4% (678 of 711), 96.6% (451 of 467) and 97.0% (454 of 468), and 95.8% (1128 of 1178) and 96.0% (1132 of 1179). The sensitivities of CT angiography were lower for detection of aneurysms smaller than 3 mm and unruptured compared with aneurysms that were 3-5 mm and ruptured (P < .001). No difference existed for the sensitivities of CT angiography for diagnosis of aneurysms in the anterior versus posterior circulation (P > .0167). Excellent or good interreader agreement was found for detection of intracranial aneurysms on a per-patient (κ = 0.982) and per-aneurysm (κ = 0.748) basis. Conclusion This large cohort study demonstrated that CT angiography had high accuracy for detection of small cerebral aneurysms, including those smaller than 3 mm. © RSNA, 2017 Online supplemental material is available for this article.


Asunto(s)
Angiografía Cerebral/métodos , Angiografía por Tomografía Computarizada/métodos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/epidemiología , Hemorragias Intracraneales/diagnóstico por imagen , Hemorragias Intracraneales/epidemiología , Adulto , Causalidad , Angiografía Cerebral/estadística & datos numéricos , China/epidemiología , Comorbilidad , Angiografía por Tomografía Computarizada/estadística & datos numéricos , Femenino , Humanos , Aneurisma Intracraneal/patología , Hemorragias Intracraneales/patología , Masculino , Persona de Mediana Edad , Prevalencia , Reproducibilidad de los Resultados , Medición de Riesgo , Sensibilidad y Especificidad
8.
Eur Radiol ; 26(11): 4184-4193, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26852216

RESUMEN

PURPOSE: To evaluate image quality and diagnostic accuracy for acute infarct detection and radiation dose of 70 kVp whole brain CT perfusion (CTP) and CT angiography (CTA) reconstructed from CTP source data. METHODS: Patients were divided into three groups (n = 50 each): group A, 80 kVp, 21 scanning time points; groups B, 70 kVp, 21 scanning time points; group C, 70 kVp, 17 scanning time points. Objective and subjective image quality of CTP and CTA were compared. Diagnostic accuracy for detecting acute infarct and cerebral artery stenosis ≥ 50 % was calculated for CTP and CTA with diffusion weighted imaging and digital subtraction angiography as reference standards. Effective radiation dose was compared. RESULTS: There were no differences in any perfusion parameter value between three groups (P > 0.05). No difference was found in subjective image quality between three groups (P > 0.05). Diagnostic accuracy for detecting acute infarct and vascular stenosis showed no difference between three groups (P > 0.05). Compared with group A, radiation doses of groups B and C were decreased by 28 % and 37 % (both P < 0.001), respectively. CONCLUSION: Compared with 80 kVp protocol, 70 kVp brain CTP allows comparable vascular and perfusion assessment and lower radiation dose while maintaining high diagnostic accuracy in detecting acute infarct. KEY POINTS: • 70 kVp whole brain CTP can provide diagnostic image quality. • 70 kVp CTP diagnostic accuracy was maintained vs. 80 kVp protocol. • 70 kVp CTP radiation doses were lower than 80 kVp protocol.


Asunto(s)
Enfermedades Arteriales Cerebrales/diagnóstico , Infarto Cerebral/diagnóstico , Encéfalo/irrigación sanguínea , Angiografía por Tomografía Computarizada/métodos , Tomografía Computarizada de Haz Cónico/métodos , Constricción Patológica/diagnóstico , Femenino , Humanos , Angiografía por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Imagen de Perfusión/métodos , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada Espiral/métodos
9.
Korean J Radiol ; 20(6): 894-908, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-31132815

RESUMEN

Kidney transplantation is the treatment of choice for patients with end-stage renal disease, as it extends survival and increases quality of life in these patients. However, chronic allograft injury continues to be a major problem, and leads to eventual graft loss. Early detection of allograft injury is essential for guiding appropriate intervention to delay or prevent irreversible damage. Several advanced MRI techniques can offer some important information regarding functional changes such as perfusion, diffusion, structural complexity, as well as oxygenation and fibrosis. This review highlights the potential of multiparametric MRI for noninvasive and comprehensive assessment of renal allograft injury.


Asunto(s)
Diagnóstico por Imagen de Elasticidad/métodos , Trasplante de Riñón/efectos adversos , Riñón/diagnóstico por imagen , Riñón/lesiones , Imágenes de Resonancia Magnética Multiparamétrica/métodos , Adolescente , Adulto , Fibrosis/diagnóstico , Fibrosis/diagnóstico por imagen , Humanos , Fallo Renal Crónico/cirugía , Masculino , Perfusión , Calidad de Vida/psicología
10.
Adv Sci (Weinh) ; 5(5): 1700847, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29876209

RESUMEN

Oxygen (O2) plays a critical role during photodynamic therapy (PDT), however, hypoxia is quite common in most solid tumors, which limits the PDT efficacy and promotes the tumor aggression. Here, a safe and multifunctional oxygen-evolving nanoplatform is costructured to overcome this problem. It is composed of a prussian blue (PB) core and chlorin e6 (Ce6) anchored periodic mesoporous organosilica (PMO) shell (denoted as PB@PMO-Ce6). In the highly integrated nanoplatform, the PB with catalase-like activity can catalyze hydrogen peroxide to generate O2, and the Ce6 transform the O2 to generate more reactive oxygen species (ROS) upon laser irradiation for PDT. This PB@PMO-Ce6 nanoplatform presents well-defined core-shell structure, uniform diameter (105 ± 12 nm), and high biocompatibility. This study confirms that the PB@PMO-Ce6 nanoplatform can generate more ROS to enhance PDT than free Ce6 in cellular level (p < 0.001). In vivo, the singlet oxygen sensor green staining, tumor volume of tumor-bearing mice, and histopathological analysis demonstrate that this oxygen-evolving nanoplatform can elevate singlet oxygen to effectively inhibit tumor growth without obvious damage to major organs. The preliminary results from this study indicate the potential of biocompatible PB@PMO-Ce6 nanoplatform to elevate O2 and ROS for improving PDT efficacy.

11.
Sci Rep ; 6: 26704, 2016 05 25.
Artículo en Inglés | MEDLINE | ID: mdl-27222163

RESUMEN

Aneurysmal subarachnoid hemorrhages have extremely high case fatality in clinic. Early and rapid identifications of ruptured intracranial aneurysms seem to be especially important. Here we evaluate clinical value of single phase contrast-enhanced dual-energy CT angiograph (DE-CTA) as a one-stop-shop tool in detecting aneurysmal subarachnoid hemorrhage. One hundred and five patients who underwent true non-enhanced CT (TNCT), contrast-enhanced DE-CTA and digital subtraction angiography (DSA) were included. Image quality and detectability of intracranial hemorrhage were evaluated and compared between virtual non-enhanced CT (VNCT) images reconstructed from DE-CTA and TNCT. There was no statistical difference in image quality (P > 0.05) between VNCT and TNCT. The agreement of VNCT and TNCT in detecting intracranial hemorrhage reached 98.1% on a per-patient basis. With DSA as reference standard, sensitivity and specificity on a per-patient were 98.3% and 97.9% for DE-CTA in intracranial aneurysm detection. Effective dose of DE-CTA was reduced by 75.0% compared to conventional digital subtraction CTA. Thus, single phase contrast-enhanced DE-CTA is optimal reliable one-stop-shop tool for detecting intracranial hemorrhage with VNCT and intracranial aneurysms with DE-CTA with substantial radiation dose reduction compared with conventional digital subtraction CTA.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Aneurisma Intracraneal/diagnóstico por imagen , Hemorragia Subaracnoidea/diagnóstico por imagen , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad
12.
ACS Appl Mater Interfaces ; 8(27): 17038-46, 2016 Jul 13.
Artículo en Inglés | MEDLINE | ID: mdl-27065014

RESUMEN

In this work, we design mesoporous silica-coated Prussian blue nanocubes with PEGyltation to construct multifunctional PB@mSiO2-PEG nanocubes. The PB@mSiO2-PEG nanocubes have good biocompatibility, excellent photothermal transformation capacity, in vivo magnetic resonance and photoacoustic imaging ability. After loading antitumor drug doxorubicin (DOX) in the PB@mSiO2-PEG nanocubes, the constructured PB@mSiO2-PEG/DOX nanoplatforms show an excellent pH-responsive drug release character within 48 h, namely, an ultralow cumulative drug release amount of 3.1% at pH 7.4 and a high release amount of 46.6% at pH 5.0. Upon near-infrared laser irradiation, the PB@mSiO2-PEG/DOX nanoplatforms show an enhanced synergistic photothermal and chemical therapeutic efficacy for breast cancer than solo photothermal therapy or chemotherapy.


Asunto(s)
Nanoestructuras , Antineoplásicos , Doxorrubicina , Humanos , Neoplasias , Fototerapia , Polietilenglicoles , Dióxido de Silicio
13.
Acad Radiol ; 22(12): 1562-70, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26432073

RESUMEN

RATIONALE AND OBJECTIVES: To assess image quality, radiation dose, and diagnostic accuracy of 70-kVp high-pitch computed tomography pulmonary angiography (CTPA) using 40 mL contrast agent and sinogram affirmed iterative reconstruction (SAFIRE) compared to 100-kVp CTPA using 60 mL contrast agent and filtered back projection. MATERIALS AND METHODS: Eighty patients underwent CTPA at either 70 kVp (group A, n = 40; 3.2 pitch, 40 mL contrast medium, and SAFIRE) or 100 kVp (group B, n = 40; 1.2 pitch, 60 mL contrast medium, and filtered back projection). Signal-to-noise ratio and contrast-to-noise ratio were calculated. Subjective image quality was evaluated using a five-grade scale, and diagnostic accuracy was assessed. Radiation doses were compared. RESULTS: Computed tomography values, signal-to-noise ratio, and contrast-to-noise ratio of pulmonary arteries were higher in group A compared to group B (all P < 0.001). Subjective image quality showed no difference between the two groups (P = 0.559) with good interobserver agreement (κ = 0.647). No difference was found regarding diagnostic accuracy between the two groups (P > 0.05). The effective dose for group A was lower by 80% compared to group B (P < 0.001). CONCLUSIONS: 70-kVp high-pitch CTPA with reduced contrast media and SAFIRE provides comparable image quality and substantial radiation dose savings compared to a routine CTPA protocol.


Asunto(s)
Angiografía/métodos , Embolia Pulmonar/diagnóstico , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Medios de Contraste/administración & dosificación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Arteria Pulmonar/diagnóstico por imagen , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador , Procesamiento de Señales Asistido por Computador , Relación Señal-Ruido
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA