Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 167
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
J Integr Neurosci ; 23(5): 98, 2024 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-38812396

RESUMEN

OBJECTIVES: In this study, we explored the effects of chiropractic spinal adjustments on resting-state electroencephalography (EEG) recordings and early somatosensory evoked potentials (SEPs) in Alzheimer's and Parkinson's disease. METHODS: In this randomized cross-over study, 14 adults with Alzheimer's disease (average age 67 ± 6 years, 2 females:12 males) and 14 adults with Parkinson's disease (average age 62 ± 11 years, 1 female:13 males) participated. The participants underwent chiropractic spinal adjustments and a control (sham) intervention in a randomized order, with a minimum of one week between each intervention. EEG was recorded before and after each intervention, both during rest and stimulation of the right median nerve. The power-spectra was calculated for resting-state EEG, and the amplitude of the N30 peak was assessed for the SEPs. The source localization was performed on the power-spectra of resting-state EEG and the N30 SEP peak. RESULTS: Chiropractic spinal adjustment significantly reduced the N30 peak in individuals with Alzheimer's by 15% (p = 0.027). While other outcomes did not reach significance, resting-state EEG showed an increase in absolute power in all frequency bands after chiropractic spinal adjustments in individuals with Alzheimer's and Parkinson's disease. The findings revealed a notable enhancement in connectivity within the Default Mode Network (DMN) at the alpha, beta, and theta frequency bands among individuals undergoing chiropractic adjustments. CONCLUSIONS: We found that it is feasible to record EEG/SEP in individuals with Alzheimer's and Parkinson's disease. Additionally, a single session of chiropractic spinal adjustment reduced the somatosensory evoked N30 potential and enhancement in connectivity within the DMN at the alpha, beta, and theta frequency bands in individuals with Alzheimer's disease. Future studies may require a larger sample size to estimate the effects of chiropractic spinal adjustment on brain activity. Given the preliminary nature of our findings, caution is warranted when considering the clinical implications. CLINICAL TRIAL REGISTRATION: The study was registered by the Australian New Zealand Clinical Trials Registry (registration number ACTRN12618001217291 and 12618001218280).


Asunto(s)
Enfermedad de Alzheimer , Estudios Cruzados , Electroencefalografía , Potenciales Evocados Somatosensoriales , Enfermedad de Parkinson , Humanos , Femenino , Masculino , Enfermedad de Parkinson/fisiopatología , Enfermedad de Parkinson/terapia , Anciano , Enfermedad de Alzheimer/fisiopatología , Enfermedad de Alzheimer/terapia , Persona de Mediana Edad , Potenciales Evocados Somatosensoriales/fisiología , Proyectos Piloto , Manipulación Quiropráctica/métodos
2.
Sensors (Basel) ; 24(4)2024 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-38400359

RESUMEN

With the astounding ability to capture a wealth of brain signals, Brain-Computer Interfaces (BCIs) have the potential to revolutionize humans' quality of life [...].


Asunto(s)
Interfaces Cerebro-Computador , Humanos , Electroencefalografía , Calidad de Vida , Encéfalo , Procesamiento de Señales Asistido por Computador
3.
Sensors (Basel) ; 23(21)2023 Oct 28.
Artículo en Inglés | MEDLINE | ID: mdl-37960487

RESUMEN

Dehydration is a common problem among older adults. It can seriously affect their health and wellbeing and sometimes leads to death, given the diminution of thirst sensation as we age. It is, therefore, essential to keep older adults properly hydrated by monitoring their fluid intake and estimating how much they drink. This paper aims to investigate the effect of surface electromyography (sEMG) features on the detection of drinking events and estimation of the amount of water swallowed per sip. Eleven individuals took part in the study, with data collected over two days. We investigated the best combination of a pool of twenty-six time and frequency domain sEMG features using five classifiers and seven regressors. Results revealed an average F-score over two days of 77.5±1.35% in distinguishing the drinking events from non-drinking events using three global features and 85.5±1.00% using three subject-specific features. The average volume estimation RMSE was 6.83±0.14 mL using one single global feature and 6.34±0.12 mL using a single subject-specific feature. These promising results validate and encourage the potential use of sEMG as an essential factor for monitoring and estimating the amount of fluid intake.


Asunto(s)
Deglución , Ingestión de Líquidos , Humanos , Anciano , Electromiografía/métodos
4.
Sensors (Basel) ; 23(24)2023 Dec 08.
Artículo en Inglés | MEDLINE | ID: mdl-38139564

RESUMEN

Smartphone applications (apps) that utilize embedded inertial sensors have the potential to provide valid and reliable estimations of different balance and gait parameters in older adults with mild balance impairment. This study aimed to assess the reliability, validity, and sensitivity of the Gait&Balance smartphone application (G&B App) for measuring gait and balance in a sample of middle- to older-aged adults with mild balance impairment in Pakistan. Community-dwelling adults over 50 years of age (N = 83, 50 female, range 50-75 years) with a Berg Balance Scale (BBS) score between 46/56 and 54/56 were included in the study. Data collection involved securing a smartphone to the participant's lumbosacral spine. Participants performed six standardized balance tasks, including four quiet stance tasks and two gait tasks (walking looking straight ahead and walking with head turns). The G&B App collected accelerometry data during these tasks, and the tasks were repeated twice to assess test-retest reliability. The tasks in quiet stance were also recorded with a force plate, a gold-standard technology for measuring postural sway. Additionally, participants completed three clinical measures, the BBS, the Functional Reach Test (FRT), and the Timed Up and Go Test (TUG). Test-retest reliability within the same session was determined using intraclass correlation coefficients (ICCs) and the standard error of measurement (SEM). Validity was evaluated by correlating the G&B App outcomes against both the force plate data and the clinical measures using Pearson's product-moment correlation coefficients. To assess the G&B App's sensitivity to differences in balance across tasks and repetitions, one-way repeated measures analyses of variance (ANOVAs) were conducted. During quiet stance, the app demonstrated moderate reliability for steadiness on firm (ICC = 0.72) and compliant surfaces (ICC = 0.75) with eyes closed. For gait tasks, the G&B App indicated moderate to excellent reliability when walking looking straight ahead for gait symmetry (ICC = 0.65), walking speed (ICC = 0.93), step length (ICC = 0.94), and step time (ICC = 0.84). The TUG correlated with app measures under both gait conditions for walking speed (r -0.70 and 0.67), step length (r -0.56 and -0.58), and step time (r 0.58 and 0.50). The BBS correlated with app measures of walking speed under both gait conditions (r 0.55 and 0.51) and step length when walking with head turns (r = 0.53). Force plate measures of total distance wandered showed adequate to excellent correlations with G&B App measures of steadiness. Notably, G&B App measures of walking speed, gait symmetry, step length, and step time, were sensitive to detecting differences in performance between standard walking and the more difficult task of walking with head turns. This study demonstrates the G&B App's potential as a reliable and valid tool for assessing some gait and balance parameters in middle-to-older age adults, with promise for application in low-income countries like Pakistan. The app's accessibility and accuracy could enhance healthcare services and support preventive measures related to fall risk.


Asunto(s)
Aplicaciones Móviles , Humanos , Femenino , Persona de Mediana Edad , Adulto , Anciano , Equilibrio Postural , Reproducibilidad de los Resultados , Estudios de Tiempo y Movimiento , Marcha
5.
Sensors (Basel) ; 22(4)2022 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-35214576

RESUMEN

Brain-computer interface performance may be reduced over time, but adapting the classifier could reduce this problem. Error-related potentials (ErrPs) could label data for continuous adaptation. However, this has scarcely been investigated in populations with severe motor impairments. The aim of this study was to detect ErrPs from single-trial EEG in offline analysis in participants with cerebral palsy, an amputation, or stroke, and determine how much discriminative information different brain regions hold. Ten participants with cerebral palsy, eight with an amputation, and 25 with a stroke attempted to perform 300-400 wrist and ankle movements while a sham BCI provided feedback on their performance for eliciting ErrPs. Pre-processed EEG epochs were inputted in a multi-layer perceptron artificial neural network. Each brain region was used as input individually (Frontal, Central, Temporal Right, Temporal Left, Parietal, and Occipital), the combination of the Central region with each of the adjacent regions, and all regions combined. The Frontal and Central regions were most important, and adding additional regions only improved performance slightly. The average classification accuracies were 84 ± 4%, 87± 4%, and 85 ± 3% for cerebral palsy, amputation, and stroke participants. In conclusion, ErrPs can be detected in participants with motor impairments; this may have implications for developing adaptive BCIs or automatic error correction.


Asunto(s)
Amputados , Interfaces Cerebro-Computador , Parálisis Cerebral , Accidente Cerebrovascular , Encéfalo , Electroencefalografía , Humanos , Accidente Cerebrovascular/diagnóstico
6.
Sensors (Basel) ; 22(23)2022 Nov 26.
Artículo en Inglés | MEDLINE | ID: mdl-36501900

RESUMEN

Balance disorders are caused by several factors related to functionality deficits in one or multiple sensory systems such as vision, vestibular, and somatosensory systems. Patients usually have difficulty explaining their dizziness, often using ambiguous words to describe their symptoms. A common practice by clinicians is to objectively evaluate the patient's dizziness by applying the Sensory Organization Test (SOT), which measures the contribution of each sensory system (vestibular, visual, somatosensory). The SOT protocol can record up to 2000 measurements in 20 s to generate the Equilibrium Score (EQS) with its five load sensors. EQS is an indicator that reflects how well a patient can maintain balance. However, its calculation only considers two instances from these 2000 measurements that reflect the maximum anterior and posterior sway angle during the test performance; therefore, there is an opportunity to perform further analysis. This article aims to use the Centre of Pressure (COP) time series generated by the SOT and describes a methodology to pre-process and reduce the dimensionality of this raw data and use it as an input for machine learning algorithms to diagnose patients with balance disorder impairments. After applying this methodology to data from 475 patients, the logistic regression model (LR) produced the highest f1-score with 76.47%, and the support vector machine (SVM) performed almost as well, with an f1-score of 76.19%.


Asunto(s)
Equilibrio Postural , Vestíbulo del Laberinto , Humanos , Mareo/diagnóstico , Mareo/etiología , Modalidades de Fisioterapia , Aprendizaje Automático
7.
J Pak Med Assoc ; 72(1): 192-193, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35099469

RESUMEN

Encapsulating peritoneal sclerosis (EPS) also known as abdominal cacoon is a rare cause of acute or subacute small bowel obstruction. It is characterized by total or partial encasement of the small bowel within a thick fibrocollagenous membrane which may be formed in response to prolonged, repetitive, and severe insult to the peritoneal mesothelium. This is frequently seen in the setting of peritoneal dialysis. However other causes may include chronic inflammation. We present a case of EPS in a male with infrequent abdominal pain, nausea and fever.


Asunto(s)
Obstrucción Intestinal , Diálisis Peritoneal , Fibrosis Peritoneal , Dolor Abdominal , Humanos , Obstrucción Intestinal/diagnóstico por imagen , Obstrucción Intestinal/etiología , Masculino , Diálisis Peritoneal/efectos adversos , Fibrosis Peritoneal/diagnóstico por imagen , Fibrosis Peritoneal/etiología , Peritoneo
8.
J Pak Med Assoc ; 72(9): 1845-1847, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36280989

RESUMEN

This retrospective study was conducted to evaluate the frequency of PET superscan in baseline staging scans of lymphoma patients.The study was conducted at the Shaukat Khanum Memorial Cancer Hospital, Lahore, from October 1, 2018 to August 31, 2019. A retrospective review of baseline PET-CT scans of 203 lymphoma patients, performed during the period of October 1, 2017 to August31,2018, was done from the institutional database. Out of these 203 patients, PET superscan pattern was observed in 13 (6.4%) patients, 08 (61.5%) males and 05 (38.5%) females. Eight (61.5%) patients had Non-Hodgkin's lymphoma, while 05 (38.5%)had Hodgkin's lymphoma. Based on TNM staging 10 (76.9%) patients had stage IV disease, 01 (07.6%) had stage III disease, and 2 (15.4%) had stage II disease. PET-CT superscan pattern is uncommon and is not dependent on the stage of the disease. It should be recognised in clinical practice as it suggests a poor prognosis.


Asunto(s)
Fluorodesoxiglucosa F18 , Linfoma , Masculino , Femenino , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones , Estudios Retrospectivos , Tomografía de Emisión de Positrones/métodos , Linfoma/diagnóstico por imagen , Estadificación de Neoplasias , Radiofármacos
9.
Stroke ; 52(7): 2266-2274, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33878894

RESUMEN

Background and Purpose: Weight loss in morbidly obese patients reduces atrial fibrillation (AF); however, it is unknown whether similar benefits are maintained in patients with obstructive sleep apnea (OSA). We sought to determine whether incident AF and stroke rates are affected by OSA after weight loss and to identify predictors of AF and stroke. Methods: Differences in laparoscopic adjustable gastric banding­induced weight loss on incident AF and stroke events in those with and without OSA in the entire and in propensity-matched cohorts were determined longitudinally, and independent predictors of AF and stroke were identified. Results: Of 827 morbidly obese patients who underwent laparoscopic adjustable gastric banding (mean age, 44±11 years; mean body mass index, 49±8 kg/m2), incident AF was documented in 4.96% and stroke in 5.44% of patients during a mean 6.0±3.2-year follow-up. Despite a similar reduction in body weight (19.6% and 21% in 3 years), new-onset AF was significantly higher in patients with OSA than without OSA in the entire (1.7% versus 0.5% per year; P<0.001) and propensity-matched cohorts. Incident stroke was higher in the OSA than in the non-OSA group (2.10% versus 0.47% per year; P<0.001), but only 20% of patients with stroke had documented AF. On multivariate analysis, OSA (hazard ratio, 2.88 [95% CI, 1.45­5.73]), age, and hypertension were independent predictors of new-onset AF, and OSA (hazard ratio, 5.84 [95% CI, 3.02­11.30]), depression, and body mass index were for stroke events. Conclusions: In morbidly obese patients who underwent laparoscopic adjustable gastric banding, despite similar weight loss, patients with OSA had a higher incidence of AF and stroke than patients without OSA. Both non-AF and AF-related factors were involved in increasing stroke risk. Further investigation is warranted into whether OSA treatment helps reduce AF or stroke events in this population.


Asunto(s)
Fibrilación Atrial/epidemiología , Cirugía Bariátrica/efectos adversos , Obesidad Mórbida/epidemiología , Apnea Obstructiva del Sueño/epidemiología , Accidente Cerebrovascular/epidemiología , Adolescente , Adulto , Anciano , Fibrilación Atrial/diagnóstico , Cirugía Bariátrica/tendencias , Femenino , Estudios de Seguimiento , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Obesidad Mórbida/diagnóstico , Obesidad Mórbida/cirugía , Estudios Prospectivos , Estudios Retrospectivos , Factores de Riesgo , Apnea Obstructiva del Sueño/diagnóstico , Apnea Obstructiva del Sueño/cirugía , Accidente Cerebrovascular/diagnóstico , Pérdida de Peso/fisiología , Adulto Joven
10.
Pacing Clin Electrophysiol ; 44(10): 1663-1670, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34319603

RESUMEN

BACKGROUND: Cardiac resynchronization therapy (CRT) involves stimulation of both right ventricle (RV) and left ventricle (LV). LV pacing from the sites of delayed electrical activation improves CRT response. The RV-LV conduction is typically measured in intrinsic rhythm. The differences in RV-LV conduction patterns and timing between intrinsic rhythm and during paced RV activation, these differences are not fully understood. METHODS: Enrolled patients were implanted with a de novo CRT device and quadripolar LV lead, with lead implant locations at the implanting physician's discretion. QRS duration and conduction delay between the RV lead and each of the four LV electrodes (D1, M2, M3, and P4) were measured during intrinsic conduction and RV pacing. RESULTS: Conduction measurements were collected from 275 patients across 14 international centers (68 ± 13 years of age, 73% male, 45% ischemic, 158 ± 22 ms QRS duration). Mean RV-LV conduction time was shorter during intrinsic conduction versus RV pacing by 59.6 ms (106.5 ± 36.5 versus 166.1 ± 32.1 ms, p < 0.001). The intra-LV activation delay between the latest and earliest activating LV electrode was also shorter during intrinsic conduction versus RV pacing by 6.6 ms (20.6 ± 13.1 vs. 27.2 ± 21.2 ms, p < 0.001). Intrinsic conduction and RV pacing resulted in a different activation order in 72.7% of patients, and the same LV activation order in 27.3%. CONCLUSIONS: Differences in RV-LV conduction time, intra-LV conduction time, and activation pattern were observed between intrinsic conduction and RV pacing. These findings highlight the importance of evaluating intrinsic versus paced ventricular activation to guide LV pacing site selection in CRT patients.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Sistema de Conducción Cardíaco/fisiopatología , Ventrículos Cardíacos/fisiopatología , Anciano , Dispositivos de Terapia de Resincronización Cardíaca , Femenino , Humanos , Masculino , Diseño de Prótesis
11.
J Pediatr Hematol Oncol ; 43(6): e826-e831, 2021 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-33661171

RESUMEN

Osteosarcoma is the most common primary malignant bone tumor in children. In addition to pulmonary metastasis, computed tomography frequently detects indeterminate pulmonary nodules (IPN). We conducted this study to determine the clinical significance of IPN in terms of progression to pulmonary metastasis and its impact on survival. It was a retrospective cohort study of pediatric nonmetastatic osteosarcoma patients treated from January 2005 to December 2018. Baseline computed tomography scans were reviewed for the presence of IPN (defined as a single nodule of <10 mm or ≥3 nodules of <5 mm). Subsequent scans were reviewed for the development of pulmonary metastasis. Of 155 patients, 31.6% (n=49) had IPN at baseline. A total of 43% (n=21) of those with IPN subsequently progressed to pulmonary metastasis compared with only 26% (n=28) of those without IPN (P<0.001) with a relative risk of 1.6 (1.03 to 2.5) in the IPN group. Patients with ≥3 IPN at baseline were at significantly greater risk of pulmonary metastasis as compared with <3 IPN (P=0.013). Overall and event-free survival in patients with and without IPN was 58% and 35%, and 72% and 46%, respectively. Our results suggest that patients with IPN may be at greater risk for progressing to pulmonary metastasis.


Asunto(s)
Neoplasias Óseas/patología , Neoplasias Pulmonares/secundario , Nódulos Pulmonares Múltiples/secundario , Osteosarcoma/patología , Adolescente , Niño , Preescolar , Femenino , Humanos , Neoplasias Pulmonares/patología , Masculino , Nódulos Pulmonares Múltiples/patología , Estudios Retrospectivos
12.
Eur J Appl Physiol ; 121(10): 2675-2720, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34164712

RESUMEN

PURPOSE: There is growing evidence that vertebral column function and dysfunction play a vital role in neuromuscular control. This invited review summarises the evidence about how vertebral column dysfunction, known as a central segmental motor control (CSMC) problem, alters neuromuscular function and how spinal adjustments (high-velocity, low-amplitude or HVLA thrusts directed at a CSMC problem) and spinal manipulation (HVLA thrusts directed at segments of the vertebral column that may not have clinical indicators of a CSMC problem) alters neuromuscular function. METHODS: The current review elucidates the peripheral mechanisms by which CSMC problems, the spinal adjustment or spinal manipulation alter the afferent input from the paravertebral tissues. It summarises the contemporary model that provides a biologically plausible explanation for CSMC problems, the manipulable spinal lesion. This review also summarises the contemporary, biologically plausible understanding about how spinal adjustments enable more efficient production of muscular force. The evidence showing how spinal dysfunction, spinal manipulation and spinal adjustments alter central multimodal integration and motor control centres will be covered in a second invited review. RESULTS: Many studies have shown spinal adjustments increase voluntary force and prevent fatigue, which mainly occurs due to altered supraspinal excitability and multimodal integration. The literature suggests physical injury, pain, inflammation, and acute or chronic physiological or psychological stress can alter the vertebral column's central neural motor control, leading to a CSMC problem. The many gaps in the literature have been identified, along with suggestions for future studies. CONCLUSION: Spinal adjustments of CSMC problems impact motor control in a variety of ways. These include increasing muscle force and preventing fatigue. These changes in neuromuscular function most likely occur due to changes in supraspinal excitability. The current contemporary model of the CSMC problem, and our understanding of the mechanisms of spinal adjustments, provide a biologically plausible explanation for how the vertebral column's central neural motor control can dysfunction, can lead to a self-perpetuating central segmental motor control problem, and how HVLA spinal adjustments can improve neuromuscular function.


Asunto(s)
Quiropráctica , Vértebras Lumbares/fisiopatología , Manipulación Espinal , Fuerza Muscular/fisiología , Humanos , Actividad Motora/fisiología , Unión Neuromuscular/fisiología
13.
Sensors (Basel) ; 21(18)2021 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-34577481

RESUMEN

Error-related potentials (ErrPs) have been proposed as a means for improving brain-computer interface (BCI) performance by either correcting an incorrect action performed by the BCI or label data for continuous adaptation of the BCI to improve the performance. The latter approach could be relevant within stroke rehabilitation where BCI calibration time could be minimized by using a generalized classifier that is continuously being individualized throughout the rehabilitation session. This may be achieved if data are correctly labelled. Therefore, the aims of this study were: (1) classify single-trial ErrPs produced by individuals with stroke, (2) investigate test-retest reliability, and (3) compare different classifier calibration schemes with different classification methods (artificial neural network, ANN, and linear discriminant analysis, LDA) with waveform features as input for meaningful physiological interpretability. Twenty-five individuals with stroke operated a sham BCI on two separate days where they attempted to perform a movement after which they received feedback (error/correct) while continuous EEG was recorded. The EEG was divided into epochs: ErrPs and NonErrPs. The epochs were classified with a multi-layer perceptron ANN based on temporal features or the entire epoch. Additionally, the features were classified with shrinkage LDA. The features were waveforms of the ErrPs and NonErrPs from the sensorimotor cortex to improve the explainability and interpretation of the output of the classifiers. Three calibration schemes were tested: within-day, between-day, and across-participant. Using within-day calibration, 90% of the data were correctly classified with the entire epoch as input to the ANN; it decreased to 86% and 69% when using temporal features as input to ANN and LDA, respectively. There was poor test-retest reliability between the two days, and the other calibration schemes led to accuracies in the range of 63-72% with LDA performing the best. There was no association between the individuals' impairment level and classification accuracies. The results show that ErrPs can be classified in individuals with stroke, but that user- and session-specific calibration is needed for optimal ErrP decoding with this approach. The use of ErrP/NonErrP waveform features makes it possible to have a physiological meaningful interpretation of the output of the classifiers. The results may have implications for labelling data continuously in BCIs for stroke rehabilitation and thus potentially improve the BCI performance.


Asunto(s)
Interfaces Cerebro-Computador , Accidente Cerebrovascular , Encéfalo , Electroencefalografía , Humanos , Redes Neurales de la Computación , Reproducibilidad de los Resultados , Accidente Cerebrovascular/diagnóstico
14.
Sensors (Basel) ; 22(1)2021 Dec 25.
Artículo en Inglés | MEDLINE | ID: mdl-35009667

RESUMEN

Advances in technology provide an opportunity to enhance the accuracy of gait and balance assessment, improving the diagnosis and rehabilitation processes for people with acute or chronic health conditions. This study investigated the validity and reliability of a smartphone-based application to measure postural stability and spatiotemporal aspects of gait during four static balance and two gait tasks. Thirty healthy participants (aged 20-69 years) performed the following tasks: (1) standing on a firm surface with eyes opened, (2) standing on a firm surface with eyes closed, (3) standing on a compliant surface with eyes open, (4) standing on a compliant surface with eyes closed, (5) walking in a straight line, and (6) walking in a straight line while turning their head from side to side. During these tasks, the app quantified the participants' postural stability and spatiotemporal gait parameters. The concurrent validity of the smartphone app with respect to a 3D motion capture system was evaluated using partial Pearson's correlations (rp) and limits of the agreement (LoA%). The within-session test-retest reliability over three repeated measures was assessed with the intraclass correlation coefficient (ICC) and the standard error of measurement (SEM). One-way repeated measures analyses of variance (ANOVAs) were used to evaluate responsiveness to differences across tasks and repetitions. Periodicity index, step length, step time, and walking speed during the gait tasks and postural stability outcomes during the static tasks showed moderate-to-excellent validity (0.55 ≤ rp ≤ 0.98; 3% ≤ LoA% ≤ 12%) and reliability scores (0.52 ≤ ICC ≤ 0.92; 1% ≤ SEM% ≤ 6%) when the repetition effect was removed. Conversely, step variability and asymmetry parameters during both gait tasks generally showed poor validity and reliability except step length asymmetry, which showed moderate reliability (0.53 ≤ ICC ≤ 0.62) in both tasks when the repetition effect was removed. Postural stability and spatiotemporal gait parameters were found responsive (p < 0.05) to differences across tasks and test repetitions. Along with sound clinical judgement, the app can potentially be used in clinical practice to detect gait and balance impairments and track the effectiveness of rehabilitation programs. Further evaluation and refinement of the app in people with significant gait and balance deficits is needed.


Asunto(s)
Aplicaciones Móviles , Marcha , Humanos , Equilibrio Postural , Reproducibilidad de los Resultados , Teléfono Inteligente , Caminata , Velocidad al Caminar
15.
Sensors (Basel) ; 21(5)2021 Feb 24.
Artículo en Inglés | MEDLINE | ID: mdl-33668229

RESUMEN

Stroke is a cerebrovascular disease (CVD), which results in hemiplegia, paralysis, or death. Conventionally, a stroke patient requires prolonged sessions with physical therapists for the recovery of motor function. Various home-based rehabilitative devices are also available for upper limbs and require minimal or no assistance from a physiotherapist. However, there is no clinically proven device available for functional recovery of a lower limb. In this study, we explored the potential use of surface electromyography (sEMG) as a controlling mechanism for the development of a home-based lower limb rehabilitative device for stroke patients. In this experiment, three channels of sEMG were used to record data from 11 stroke patients while performing ankle joint movements. The movements were then decoded from the sEMG data and their correlation with the level of motor impairment was investigated. The impairment level was quantified using the Fugl-Meyer Assessment (FMA) scale. During the analysis, Hudgins time-domain features were extracted and classified using linear discriminant analysis (LDA) and artificial neural network (ANN). On average, 63.86% ± 4.3% and 67.1% ± 7.9% of the movements were accurately classified in an offline analysis by LDA and ANN, respectively. We found that in both classifiers, some motions outperformed others (p < 0.001 for LDA and p = 0.014 for ANN). The Spearman correlation (ρ) was calculated between the FMA scores and classification accuracies. The results indicate that there is a moderately positive correlation (ρ = 0.75 for LDA and ρ = 0.55 for ANN) between the two of them. The findings of this study suggest that a home-based EMG system can be developed to provide customized therapy for the improvement of functional lower limb motion in stroke patients.


Asunto(s)
Articulación del Tobillo , Electromiografía , Movimiento , Rehabilitación de Accidente Cerebrovascular/instrumentación , Accidente Cerebrovascular/terapia , Humanos
16.
J Pak Med Assoc ; 71(4): 1290-1291, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34125794

RESUMEN

Spinal subdural haematoma (SSDH) is very rare but potentially life debilitating spinal vascular condition, often developing acutely. Usually managed conservatively but may require immediate evacuation to prevent potential harm to the spinal cord. Predisposing factors can be spontaneous or iatrogenic. MRI remains the modality of choice to diagnose and see the age and extent of haemorrhage. We hereby present the case of a young child who developed iatrogenic spinal subdural haematoma.


Asunto(s)
Hematoma Subdural Espinal , Niño , Hematoma Subdural Espinal/diagnóstico por imagen , Hematoma Subdural Espinal/etiología , Hematoma Subdural Espinal/cirugía , Humanos , Enfermedad Iatrogénica , Imagen por Resonancia Magnética , Médula Espinal
17.
Medicina (Kaunas) ; 57(6)2021 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-34071880

RESUMEN

The current COVID-19 pandemic has necessitated the need to find healthcare solutions that boost or support immunity. There is some evidence that high-velocity, low-amplitude (HVLA) controlled vertebral thrusts have the potential to modulate immune mediators. However, the mechanisms of the link between HVLA controlled vertebral thrusts and neuroimmune function and the associated potential clinical implications are less clear. This review aims to elucidate the underlying mechanisms that can explain the HVLA controlled vertebral thrust--neuroimmune link and discuss what this link implies for clinical practice and future research needs. A search for relevant articles published up until April 2021 was undertaken. Twenty-three published papers were found that explored the impact of HVLA controlled vertebral thrusts on neuroimmune markers, of which eighteen found a significant effect. These basic science studies show that HVLA controlled vertebral thrust influence the levels of immune mediators in the body, including neuropeptides, inflammatory markers, and endocrine markers. This narravtive review discusses the most likely mechanisms for how HVLA controlled vertebral thrusts could impact these immune markers. The mechanisms are most likely due to the known changes in proprioceptive processing that occur within the central nervous system (CNS), in particular within the prefrontal cortex, following HVLA spinal thrusts. The prefrontal cortex is involved in the regulation of the autonomic nervous system, the hypothalamic-pituitary-adrenal axis and the immune system. Bi-directional neuro-immune interactions are affected by emotional or pain-related stress. Stress-induced sympathetic nervous system activity also alters vertebral motor control. Therefore, there are biologically plausible direct and indirect mechanisms that link HVLA controlled vertebral thrusts to the immune system, suggesting HVLA controlled vertebral thrusts have the potential to modulate immune function. However, it is not yet known whether HVLA controlled vertebral thrusts have a clinically relevant impact on immunity. Further research is needed to explore the clinical impact of HVLA controlled vertebral thrusts on immune function.


Asunto(s)
COVID-19 , Manipulación Espinal , Humanos , Sistema Hipotálamo-Hipofisario , Pandemias , Sistema Hipófiso-Suprarrenal , SARS-CoV-2
18.
Sensors (Basel) ; 20(8)2020 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-32344692

RESUMEN

Event related potentials (ERPs) provide insight into the neural activity generated in response to motor, sensory and cognitive processes. Despite the increasing use of ERP data in clinical research little is known about the reliability of human manual ERP labelling methods. Intra-rater and inter-rater reliability were evaluated in five electroencephalography (EEG) experts who labelled the peak negativity of averaged movement related cortical potentials (MRCPs) derived from thirty datasets. Each dataset contained 50 MRCP epochs from healthy people performing cued voluntary or imagined movement, or people with stroke performing cued voluntary movement. Reliability was assessed using the intraclass correlation coefficient and standard error of measurement. Excellent intra- and inter-rater reliability was demonstrated in the voluntary movement conditions in healthy people and people with stroke. In comparison reliability in the imagined condition was low to moderate. Post-hoc secondary epoch analysis revealed that the morphology of the signal contributed to the consistency of epoch inclusion; potentially explaining the differences in reliability seen across conditions. Findings from this study may inform future research focused on developing automated labelling methods for ERP feature extraction and call to the wider community of researchers interested in utilizing ERPs as a measure of neurophysiological change or in the delivery of EEG-driven interventions.


Asunto(s)
Potenciales Evocados/fisiología , Accidente Cerebrovascular/fisiopatología , Adulto , Anciano , Intervalos de Confianza , Electroencefalografía , Procesamiento Automatizado de Datos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
19.
Sensors (Basel) ; 20(23)2020 Nov 26.
Artículo en Inglés | MEDLINE | ID: mdl-33256073

RESUMEN

Brain- and muscle-triggered exoskeletons have been proposed as a means for motor training after a stroke. With the possibility of performing different movement types with an exoskeleton, it is possible to introduce task variability in training. It is difficult to decode different movement types simultaneously from brain activity, but it may be possible from residual muscle activity that many patients have or quickly regain. This study investigates whether nine different motion classes of the hand and forearm could be decoded from forearm EMG in 15 stroke patients. This study also evaluates the test-retest reliability of a classical, but simple, classifier (linear discriminant analysis) and advanced, but more computationally intensive, classifiers (autoencoders and convolutional neural networks). Moreover, the association between the level of motor impairment and classification accuracy was tested. Three channels of surface EMG were recorded during the following motion classes: Hand Close, Hand Open, Wrist Extension, Wrist Flexion, Supination, Pronation, Lateral Grasp, Pinch Grasp, and Rest. Six repetitions of each motion class were performed on two different days. Hudgins time-domain features were extracted and classified using linear discriminant analysis and autoencoders, and raw EMG was classified with convolutional neural networks. On average, 79 ± 12% and 80 ± 12% (autoencoders) of the movements were correctly classified for days 1 and 2, respectively, with an intraclass correlation coefficient of 0.88. No association was found between the level of motor impairment and classification accuracy (Spearman correlation: 0.24). It was shown that nine motion classes could be decoded from residual EMG, with autoencoders being the best classification approach, and that the results were reliable across days; this may have implications for the development of EMG-controlled exoskeletons for training in the patient's home.


Asunto(s)
Electromiografía , Mano , Accidente Cerebrovascular , Humanos , Movimiento , Reproducibilidad de los Resultados , Accidente Cerebrovascular/diagnóstico , Articulación de la Muñeca
20.
Sensors (Basel) ; 20(6)2020 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-32183473

RESUMEN

Electromyography (EMG) is a measure of electrical activity generated by the contraction of muscles. Non-invasive surface EMG (sEMG)-based pattern recognition methods have shown the potential for upper limb prosthesis control. However, it is still insufficient for natural control. Recent advancements in deep learning have shown tremendous progress in biosignal processing. Multiple architectures have been proposed yielding high accuracies (>95%) for offline analysis, yet the delay caused due to optimization of the system remains a challenge for its real-time application. From this arises a need for optimized deep learning architecture based on fine-tuned hyper-parameters. Although the chance of achieving convergence is random, however, it is important to observe that the performance gain made is significant enough to justify extra computation. In this study, the convolutional neural network (CNN) was implemented to decode hand gestures from the sEMG data recorded from 18 subjects to investigate the effect of hyper-parameters on each hand gesture. Results showed that the learning rate set to either 0.0001 or 0.001 with 80-100 epochs significantly outperformed (p < 0.05) other considerations. In addition, it was observed that regardless of network configuration some motions (close hand, flex hand, extend the hand and fine grip) performed better (83.7% ± 13.5%, 71.2% ± 20.2%, 82.6% ± 13.9% and 74.6% ± 15%, respectively) throughout the course of study. So, a robust and stable myoelectric control can be designed on the basis of the best performing hand motions. With improved recognition and uniform gain in performance, the deep learning-based approach has the potential to be a more robust alternative to traditional machine learning algorithms.


Asunto(s)
Miembros Artificiales , Electromiografía/métodos , Gestos , Redes Neurales de la Computación , Procesamiento de Señales Asistido por Computador , Adulto , Algoritmos , Mano/fisiología , Humanos , Masculino , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA