1.
Biochim Biophys Acta ; 412(1): 99-108, 1975 Nov 18.
Artículo en Inglés | MEDLINE | ID: mdl-1191679

RESUMEN

Five homogeneous closely related glycoproteins were isolated from human colostrum whey, and their molecular weights and carbohydrate contents ranged from 26 000 to 35 000 and from 50 to 80%, respectively. All had the Lactobacillus bifidus var. Pennsylvanicus growth-promoting activity, which was not substantially altered by desialization. Neither human colostrum, milk or the glycoproteins had any cellular immunity-mediating activity. Degradation of the carbohydrate moieties of these glycoproteins indicated that each contained non-identical carbohydrate chains.


Asunto(s)
Calostro/análisis , Glicoproteínas/análisis , Aminoácidos/análisis , Animales , Formación de Anticuerpos , Bioensayo , Inhibición de Migración Celular , Femenino , Glicoproteínas/inmunología , Glicoproteínas/farmacología , Humanos , Lactobacillus/efectos de los fármacos , Macrófagos/inmunología , Leche Humana/análisis , Peso Molecular , Embarazo
2.
Am J Clin Nutr ; 32(7): 1428-32, 1979 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-572132

RESUMEN

Human milk casein samples were digested with trypsin and chymotrypsin, and a glycopolypeptide fraction was isolated from the soluble portion of the digests by a series of gel filtration steps. The glycopeptide fraction stimulated the growth of Lactobacillus bifidus subspecies pennsylvanicius to the same extent as a whey glycopolypeptide fraction previously isolated (Pediat. Res. 10: 1, 1976). It contained between 60 and 70% carbohydrate consisting of galactose, galactosamine, glucosamine, fucose, and sialic acid. This, along with its apparent molecular weight of near 30,000 was also similar to the respective parameters of the whey glycopolypeptide. It is proposed that human milk casein may serve a dual function: that serving the nutritional needs of the breast-fed infant, and that stimulating the growth of L. bifidus subspecies pennsylvanicus. Additionally, the whey glycopolypeptide may arise from casein through proteolysis by an endogenous milk protease.


Asunto(s)
Actinomycetaceae/crecimiento & desarrollo , Caseínas/aislamiento & purificación , Glicopéptidos/aislamiento & purificación , Leche Humana/análisis , Actinomycetaceae/efectos de los fármacos , Aminoácidos/análisis , Animales , Carbohidratos/análisis , Bovinos , Fenómenos Químicos , Química , Quimotripsina , Femenino , Glicopéptidos/farmacología , Humanos , Leche/análisis , Embarazo , Tripsina
3.
Am J Clin Pathol ; 103(2): 244-51, 1995 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-7856571

RESUMEN

A two-phase, laboratory and bedside, evaluation of blood glucose meters was conducted in this study. Four meters, the AccuData Easy (Boehringer-Mannheim, Indianapolis, IN), HemoCue Glucose (HemoCue, Mission Viejo, CA), LifeScan One Touch II (LifeScan, Milpitas, CA), and Miles Encore QA (Miles, Elkhart, IN) systems, were compared to the Nova Stat Profile 5 (Nova, Waltham, MA) as the laboratory reference. Precision, linearity, correlation to the laboratory method, interference from hematocrit, data management, and operator preference were examined. None of the meters were found to satisfy all of the study's evaluation criteria. Therefore, institutions must weigh which criteria are most important to their individual settings. Although the HemoCue Glucose was found to be technically superior, this meter had no data management capabilities. The Encore QA had greater variance and low bias, whereas the AccuData Easy had bias affected by hematocrit and glucose concentration, and the One Touch II had a negative hematocrit bias and limited linear range when compared to the Nova. Only meters meeting both minimal analytical performance and computerization requirements, the One Touch II and AccuData Easy, were selected for further evaluation. At the bedside, the One Touch II demonstrated performance consistent with the lab evaluation, whereas the AccuData Easy showed greater imprecision in the low glucose range and a correlation that varied with sample type: capillary, venous, or arterial blood. This evaluation indicates that the clinician must interpret near-patient glucose results with respect to meter limitations. FDA approval and marketing statistics, alone, are insufficient to judge the performance of the meters in routine institutional use. Independent method validation, under actual operating conditions, is a better means of predicting future performance of the meters.


Asunto(s)
Glucemia/análisis , Química Clínica/instrumentación , Química Clínica/métodos , Laboratorios , Estudios de Evaluación como Asunto , Humanos , Monitoreo Fisiológico , Garantía de la Calidad de Atención de Salud
4.
Am J Clin Pathol ; 111(4): 547-56, 1999 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-10191777

RESUMEN

Technical performance and data management features are prominent criteria in the selection of an appropriate meter for a point-of-care glucose testing program. We evaluated the technical performance of 5 currently available glucose meters with data management capabilities. The performance of all 5 meters was technically equivalent. Linear regression slopes vs the reference method are in the range of 0.94 to 1.02 and indicate correlation more to plasma values than to whole blood values. The percentage of glucose meter results within +/- 15% of the laboratory value was at least 90%; however, the percentage within +/- 10% was 75% to 87% for most meters. Within-day and between-day precision ranged from 2% to 5% coefficient of variation. Evaluation of linearity with glucose-spiked venous specimens demonstrated that the linearity of each meter agreed with the manufacturer's stated range in most cases. Meter glucose values tended to bias negative as the hematocrit increased, an effect that may be more pronounced at higher glucose concentrations. No volume effects were noted between 5 microL and 40 microL. The results suggest that all meters tested will likely satisfy technical performance criteria in a hospital setting and that selection of a system for point-of-care glucose testing will be influenced by the institution's data management requirements.


Asunto(s)
Glucemia/análisis , Sistemas de Información/instrumentación , Sistemas de Atención de Punto , Estudios de Evaluación como Asunto , Reacciones Falso Negativas , Hematócrito , Humanos , Control de Calidad , Análisis de Regresión , Sensibilidad y Especificidad
5.
Clin Lab Med ; 21(2): 305-19, viii-ix, 2001 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-11396085

RESUMEN

Point-of-care testing is an increasingly popular means of delivering diagnostic testing closer to the site of patient care. Although point-of-care glucose testing devices have been around for over a decade, concerns about the quality of the results still plague the industry. Changes in federal and state laws that treat point-of-care testing as an extension of the core laboratory promise to improve the quality of testing. The most challenging aspect of quality testing is selection of the appropriate method (core laboratory versus point-of-care test) for the optimal patient outcome.


Asunto(s)
Glucemia/análisis , Sistemas de Atención de Punto , Automonitorización de la Glucosa Sanguínea , Humanos , Laboratorios de Hospital , Garantía de la Calidad de Atención de Salud
10.
Pediatr Res ; 10(1): 1-5, 1976 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-1246459

RESUMEN

Two milk-specific glycoprotein fractions and serum orosomucoid were isolated from mature human milk. One of the milk-specific glycoproteins was homogeneous and was termed glycoprotein A. Its sedimentation and diffusion constants were 2.6 S and 6.3 F, respectively, giving a molecular weight of 29,5000. It contained some 70% carbohydrate consisting of sialic acid, galactose, fucose, glucosamine, and galactosamine. It was not immunologically related to serum orosomucoid. The other glycoprotein, called glycoprotein B, was heterogeneous with an average molecular weight of near 4,000, and carbohydrate comprised some 75% of its weight. Both glycoprotein fractions supported the growth of Lactobacillus bifidus var. Penn. Removal of sialic acid enhanced the growth-promoting activity of glycoprotein B but not of A.


Asunto(s)
Glicoproteínas/aislamiento & purificación , Leche Humana/análisis , Orosomucoide/aislamiento & purificación , Fraccionamiento Químico , Femenino , Glicoproteínas/metabolismo , Glicoproteínas/farmacología , Humanos , Lactobacillus/crecimiento & desarrollo , Peso Molecular
11.
Clin Lab Manage Rev ; 13(6): 341-50, 1999.
Artículo en Inglés | MEDLINE | ID: mdl-10747660

RESUMEN

Pathologists and nurses have only recently cooperated in point-of-care testing (POCT), after accreditation organizations recommended that the laboratories take responsibility for managing the quality of patient-care testing conducted at the bedside. Laboratories are charged with ensuring that patient-care tests generate comparable results, regardless of the location or method. Many home testing devices, when used in hospitals, physicians' office laboratories, and mobile nursing practices, have presented technical and operational issues that were not foreseen from home use. These problems arise from a number of factors: the way the devices are used, the patient population, and even differences in sample type. Thus, to be successful, management of POCT in the health-care environment requires interdisciplinary cooperation of clinical nursing staff and laboratory staff. The article identifies problems in POCT, describes some solutions, and examines how well these solutions have worked from a laboratory perspective.


Asunto(s)
Sistemas de Información en Laboratorio Clínico/normas , Sistemas de Atención de Punto/normas , Garantía de la Calidad de Atención de Salud/tendencias , Sistemas de Información en Laboratorio Clínico/tendencias , Humanos , Grupo de Atención al Paciente/normas , Grupo de Atención al Paciente/tendencias , Sistemas de Atención de Punto/tendencias
12.
Biochem J ; 135(4): 875-80, 1973 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-4778282

RESUMEN

A glycoprotein was isolated from the M-1 acid glycoprotein fraction of human colostrum. It had a molecular weight of 31200 and contained 27% galactose, 21.7% hexosamine, 8.0% fucose and 10.8% sialic acid by weight. The glycoprotein had no absorption maxima in the 240-300nm region, and was virtually free of ABH(O) and M and N blood-group activity. Alkaline borohydride cleavage of the glycoprotein resulted predominantly in the destruction of threonine and galactosamine.


Asunto(s)
Calostro/análisis , Glicoproteínas/aislamiento & purificación , Borohidruros , Cromatografía , Cromatografía DEAE-Celulosa , Electroforesis , Femenino , Fucosa/análisis , Galactosamina , Galactosa/análisis , Hexosaminas/análisis , Humanos , Peso Molecular , Ácidos Neuramínicos/análisis , Embarazo , Espectrofotometría , Treonina , Ultracentrifugación
13.
Clin Chem ; 40(7 Pt 1): 1312-6, 1994 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-8013105

RESUMEN

This automated assay determines the concentration of the antidepressant fluoxetine (Prozac) and its active metabolite norfluoxetine in serum by reversed-phase HPLC with spectrophotometric detection. Extraction, injection, and quantification are performed by the Gilson Aspec automated sample handler. The patient's specimen, with added protriptyline as internal standard, is extracted with solid-phase and liquid-liquid methods. Separation is conducted isocratically on a 5-microns (particle size) Supelcosil LC-8-DB reversed-phase column with a triethylamine acetate:acetonitrile mobile phase. The detection limit is 10 micrograms/L and absorbance varies linearly with concentration between 20 and 1,000 micrograms/L for both compounds. Mean recovery was 62% for fluoxetine and 70% for norfluoxetine over linear limits. Within-run and day-to-day imprecision (CV), evaluated at three concentrations (50, 200, and 500 micrograms/L), ranged from 2% to 7%. An extensive interference study of 108 drugs was conducted. Results (n = 58) by the automated method (y) correlated well with those by a manual HPLC method (x): y = 0.96x + 10.20 (r = 0.951, Sylx = 42.9) for fluoxetine, and y = 0.95x - 1.37 (r = 0.917, Sylx = 47.2) for norfluoxetine.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Fluoxetina/análogos & derivados , Fluoxetina/sangre , Autoanálisis , Cromatografía Líquida de Alta Presión/estadística & datos numéricos , Humanos , Control de Calidad , Sensibilidad y Especificidad
14.
Crit Care Nurs Q ; 24(1): 25-38; quiz 2 p following 75, 2001 May.
Artículo en Inglés | MEDLINE | ID: mdl-11868692

RESUMEN

Point-of-care testing (POCT) is an increasingly popular method of delivering laboratory testing. Management of POCT is challenging given the variety of devices, locations, and staff that need to be coordinated to ensure quality results and meet regulatory guidelines. Electronic capture and transfer of data are preferred for managing POCT, but there is currently no standard method of connecting different devices. Johns Hopkins Medical Institutions (JHMI) developed a common data management system with interfaces to all of its POCT devices. All POCT data are collected in one database and analyzed in a similar fashion. Where data were once collected by carrying laptops to each nursing unit, the POCT devices can now connect directly to the database over the Internet. Algorithms have been created to automate the data analysis and review process. Over the several years that this software has been used, JHMI has experienced improved quality, accuracy, and management of its POCT program. The labor saved by increased automation of data review is refocused on enhancing the performance and scope of the program. Current connectivity and analysis algorithms have future application to remote consultation, management of home self-monitoring patients, and examination of real-time data.


Asunto(s)
Sistemas de Información en Laboratorio Clínico/organización & administración , Laboratorios de Hospital/organización & administración , Sistemas de Atención de Punto/organización & administración , Centros Médicos Académicos/organización & administración , Baltimore , Hospitales Universitarios/organización & administración , Humanos , Gestión de la Información , Desarrollo de Programa , Evaluación de Programas y Proyectos de Salud , Garantía de la Calidad de Atención de Salud , Sensibilidad y Especificidad , Integración de Sistemas
15.
J Chromatogr B Biomed Appl ; 677(1): 204-8, 1996 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-8925098

RESUMEN

A sensitive normal-phase high-performance liquid chromatographic method using a bonded-phase aminosilica column has been developed for the measurement of the spermicide nonoxynol-9 in vaginal lavage fluid. The mean multiple correlation coefficient (r2) for nonoxynol-9 was 0.999 over the calibration range 3.125-50 micrograms/ml for the standards. Quality control samples measured at two different concentration levels gave intra-day precision values (coefficient of variation, C.V.) in the range of 0.61 to 1.63% and the intra-day accuracy values (mean relative error, M.R.E.) in the range of 0.13-0.62%. Inter-day precision and accuracy values from five different calibration standard concentration values ranged from 2.25 to 5.09% C.V. and 4.02 to 7.56% M.R.E. Nonoxynol-9 samples examined for peak area stability at room temperature over a 24-h time period had a M.R.E. of 14.9%. Quality control samples stored at -70 degrees C, and tested after one month by comparison to baseline samples, had a M.R.E. of -10% and 7.53% for the low and high quality control samples, respectively. The method is sensitive and simple, with short runtimes, to enable the processing of numerous samples from a clinical trial.


Asunto(s)
Nonoxinol/análisis , Espermicidas/análisis , Vagina/química , Calibración , Cromatografía Líquida de Alta Presión , Femenino , Humanos , Control de Calidad , Estándares de Referencia , Reproducibilidad de los Resultados , Manejo de Especímenes , Espectrometría de Fluorescencia , Irrigación Terapéutica
16.
Anesth Analg ; 97(2): 355-357, 2003 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-12873916

RESUMEN

UNLABELLED: Children presenting with pyloric stenosis have hypochloremic metabolic alkalosis and their serum potassium levels are thought to be low or normal. We reviewed potassium levels in infants with pyloric stenosis. Thirty-six percent of patients with pyloric stenosis had increased serum potassium levels. We conclude that hyperkalemia may be more common in children with pyloric stenosis than previously thought. IMPLICATIONS: A significant number of infants with pyloric stenosis have a serum potassium value above the normal limit.


Asunto(s)
Hiperpotasemia/complicaciones , Estenosis Pilórica/complicaciones , Anestesia , Humanos , Lactante , Fármacos Neuromusculares Despolarizantes , Fármacos Neuromusculares no Despolarizantes , Potasio/sangre , Estenosis Pilórica/cirugía , Estudios Retrospectivos , Succinilcolina
17.
Clin Chem ; 43(11): 2099-105, 1997 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-9365394

RESUMEN

A prototype Toxi.Prep (TP) system that utilizes solid-phase extraction (SPE) has been developed as a method for broad-spectrum drug screening and identification of tetrahydrocannabinol (THC) metabolites in urine. TP can simultaneously extract up to seven specimens while automating the process of sample extraction, washing, and elution onto a chromatogram. TP was compared with the Toxi. Lab A (TL-A) system for extraction of basic drugs only. In a blind study, 33 distinct drugs and metabolites were detected in 55 urines over 13 runs. Of the drug occurrences, 68.8% (141 of 205) were detected on both TP and TL-A. Of the 13 runs, quinidine and quinine, nortriptyline metabolites, and diphenhydramine were noted more frequently on TP than TL-A, whereas nicotine and metabolites, morphine, and methadone metabolites were more frequently noted on TL-A. Twenty specimens were analyzed for THC metabolites. Of the cases positive for THC metabolites, 100% (16 of 16) were positive by both methods. Time and motion studies for all runs proved an overall labor reduction for extraction and spotting by approximately 40%.


Asunto(s)
Dronabinol/orina , Detección de Abuso de Sustancias/instrumentación , Adulto , Niño , Cromatografía en Capa Delgada/instrumentación , Cromatografía en Capa Delgada/métodos , Dronabinol/metabolismo , Humanos , Reproducibilidad de los Resultados , Detección de Abuso de Sustancias/métodos
18.
Clin Chem ; 46(4): 543-50, 2000 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-10759479

RESUMEN

BACKGROUND: Point-of-care testing (POCT) can provide rapid test results, but its impact on patient care is not well documented. We investigated the ability of POCT to decrease inpatient and outpatient waiting times for cardiovascular procedures. METHODS: We prospectively studied, over a 7-month period, 216 patients requiring diagnostic laboratory testing for coagulation (prothrombin time/activated partial thromboplastin time) and/or renal function (urea nitrogen, creatinine, sodium, and potassium) before elective invasive cardiac and radiologic procedures. Overall patient management and workflow were examined in the initial phase. In phase 2, we implemented POCT but utilized central laboratory results for patient management. In phase 3, therapeutic decisions were based on POCT results. The final phase, phase 4, sought to optimize workflow around the availability of POCT. Patient wait and timing of phlebotomy, availability of laboratory results, and therapeutic action were monitored. Split sampling allowed comparability of POCT and central laboratory results throughout the study. RESULTS: In phase 1, 44% of central laboratory results were not available before the scheduled time for procedure (n = 135). Mean waiting times (arrival to procedure) were 188 +/- 54 min for patients who needed renal testing (phase 2; n = 14) and 171 +/- 76 min for those needing coagulation testing (n = 24). For patients needing renal testing, POCT decreased patient wait times (phases 3 and 4 combined, 141 +/- 52 min; n = 18; P = 0.02). For patients needing coagulation testing, wait times improved only when systematic changes were made in workflow (phase 4, 109 +/- 41 min; n = 12; P = 0.01). CONCLUSIONS: Although POCT has the potential to provide beneficial patient outcomes, merely moving testing from a central laboratory to the medical unit does not guarantee improved outcomes. Systematic changes in patient management may be required.


Asunto(s)
Evaluación de Resultado en la Atención de Salud , Sistemas de Atención de Punto , Procedimientos Quirúrgicos Cardiovasculares , Humanos , Pruebas de Función Renal , Tiempo de Protrombina , Radiología Intervencionista , Factores de Tiempo
19.
Crit Care Med ; 28(6): 2081-5, 2000 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-10890668

RESUMEN

OBJECTIVE: To evaluate the analytical performance of the SenDx 100 portable blood gas and electrolyte analyzer (SenDx Medical, Carlsbad, CA). DESIGN: Accuracy was evaluated by correlation of whole blood patient samples with the Nova Stat Profile 5 (Nova Biomedical, Waltham, MA) and the Ciba Corning 865 (Chiron Diagnostics, Medford, MA). Precision was evaluated using quality control materials (RNA Medical, Acton, MA). SETTING: Critical care laboratories and operating rooms in two institutions. MEASUREMENTS AND MAIN RESULTS: Precision studies performed at three different concentration levels for each analyte demonstrated intra-assay precision of < or =2.5% coefficient of variation and interassay precision of < or =4.0% coefficient of variation in all cases. Analysis of patient specimens in general showed good to excellent correlation to reference analyzers. Regression variables are tabulated. CONCLUSIONS: The SenDx 100 portable blood gas and electrolyte analyzer is a simple and easy to use analyzer demonstrating acceptable performance compared with reference methods.


Asunto(s)
Análisis de los Gases de la Sangre/instrumentación , Electrólitos/sangre , Sistemas de Atención de Punto , Humanos , Reproducibilidad de los Resultados