Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Neuroimage ; 214: 116761, 2020 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-32198050

RESUMEN

Instantaneous phase of brain oscillations in electroencephalography (EEG) is a measure of brain state that is relevant to neuronal processing and modulates evoked responses. However, determining phase at the time of a stimulus with standard signal processing methods is not possible due to the stimulus artifact masking the future part of the signal. Here, we quantify the degree to which signal-to-noise ratio and instantaneous amplitude of the signal affect the variance of phase estimation error and the precision with which "ground truth" phase is even defined, using both the variance of equivalent estimators and realistic simulated EEG data with known synthetic phase. Necessary experimental conditions are specified in which pre-stimulus phase estimation is meaningfully possible based on instantaneous amplitude and signal-to-noise ratio of the oscillation of interest. An open source toolbox is made available for causal (using pre-stimulus signal only) phase estimation along with a EEG dataset consisting of recordings from 140 participants and a best practices workflow for algorithm optimization and benchmarking. As an illustration, post-hoc sorting of open-loop transcranial magnetic stimulation (TMS) trials according to pre-stimulus sensorimotor µ-rhythm phase is performed to demonstrate modulation of corticospinal excitability, as indexed by the amplitude of motor evoked potentials.


Asunto(s)
Algoritmos , Encéfalo/fisiología , Electroencefalografía/métodos , Procesamiento de Señales Asistido por Computador , Adulto , Benchmarking , Potenciales Evocados Motores/fisiología , Femenino , Humanos , Masculino , Tractos Piramidales/fisiología , Estimulación Magnética Transcraneal/métodos , Adulto Joven
2.
Neuroimage ; 220: 117082, 2020 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-32593801

RESUMEN

Transcranial magnetic stimulation (TMS) protocols often include a manual search of an optimal location and orientation of the coil or peak stimulating electric field to elicit motor responses in a target muscle. This target search is laborious, and the result is user-dependent. Here, we present a closed-loop search method that utilizes automatic electronic adjustment of the stimulation based on the previous responses. The electronic adjustment is achieved by multi-locus TMS, and the adaptive guiding of the stimulation is based on the principles of Bayesian optimization to minimize the number of stimuli (and time) needed in the search. We compared our target-search method with other methods, such as systematic sampling in a predefined cortical grid. Validation experiments on five healthy volunteers and further offline simulations showed that our adaptively guided search method needs only a relatively small number of stimuli to provide outcomes with good accuracy and precision. The automated method enables fast and user-independent optimization of stimulation parameters in research and clinical applications of TMS.


Asunto(s)
Potenciales Evocados Motores/fisiología , Corteza Motora/fisiología , Estimulación Magnética Transcraneal/métodos , Adulto , Algoritmos , Teorema de Bayes , Femenino , Humanos , Masculino
3.
Neuroimage ; 203: 116194, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31525495

RESUMEN

Short-interval intracortical inhibition (SICI) has been studied with paired-pulse transcranial magnetic stimulation (TMS) by administering two pulses at a millisecond-scale interstimulus interval (ISI) to a single cortical target. It has, however, been difficult to study the interaction of nearby cortical targets with paired-pulse TMS. To overcome this limitation, we have developed a multi-locus TMS (mTMS) device, which allows controlling the stimulus location electronically. Here, we applied mTMS to study SICI in primary motor cortex with paired pulses targeted to adjacent locations, aiming to quantify the extent of the cortical region producing SICI in the location of a test stimulus. We varied the location and timing of the conditioning stimulus with respect to a test stimulus targeted to the cortical hotspot of the abductor pollicis brevis (APB) in order to study their effects on motor evoked potentials. We further applied a two-coil protocol with the conditioning stimulus given by an oval coil only to the surroundings of the APB hotspot, to which a subsequent test stimulus was administered with a figure-of-eight coil. The strongest SICI occurred at ISIs below 1 ms and at ISIs around 2.5 ms. These ISIs increased when the conditioning stimulus receded from the APB hotspot. Our two-coil paired-pulse TMS study suggests that SICI at ISIs of 0.5 and 2.5 ms originate from different mechanisms or neuronal elements.


Asunto(s)
Corteza Motora/fisiología , Inhibición Neural , Estimulación Magnética Transcraneal/instrumentación , Estimulación Magnética Transcraneal/métodos , Adulto , Potenciales Evocados Motores , Femenino , Humanos , Masculino , Adulto Joven
4.
Exp Brain Res ; 237(6): 1503-1510, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30919012

RESUMEN

Chronic neuropathic pain is known to alter the primary motor cortex (M1) function. Less is known about the normal, physiological effects of experimental neurogenic pain on M1. The objective of this study is to determine how short-interval intracortical inhibition (SICI) is altered in the M1 representation area of a muscle exposed to experimental pain compared to SICI of another muscle not exposed to pain. The cortical representation areas of the right abductor pollicis brevis (APB) and biceps brachii (BB) muscles of 11 subjects were stimulated with a multi-locus transcranial magnetic stimulation device while the resulting motor-evoked potentials (MEPs) were recorded with electromyography. Single- and paired-pulse TMS was administered in seven conditions, including one with the right hand placed in cold water. The stimulation intensity for the conditioning pulses in the paired-pulse examination was 80% of the resting motor threshold (RMT) of the stimulated site and 120% of RMT for both the test and single pulses. The paired-pulse MEP amplitudes were normalized with the mean amplitude of the single-pulse MEPs of the same condition and muscle. SICI was compared between conditions. After the cold pain, the normalized paired-pulse MEP amplitudes decreased in APB, but not in BB, indicating that SICI was potentially increased only in the cortical area of the muscle subjected to pain. These data suggest that SICI is increased in the M1 representation area of a hand muscle shortly after exposure to pain has ended, which implies that short-lasting pain can alter the inhibitory balance in M1.


Asunto(s)
Dolor Agudo/fisiopatología , Potenciales Evocados Motores/fisiología , Corteza Motora/fisiología , Músculo Esquelético/fisiología , Inhibición Neural/fisiología , Neuralgia/fisiopatología , Adulto , Brazo/fisiología , Electromiografía , Femenino , Humanos , Masculino , Estimulación Magnética Transcraneal
5.
Hum Brain Mapp ; 39(6): 2405-2411, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29498765

RESUMEN

State-of-the-art noninvasive electromagnetic recording techniques allow observing neuronal dynamics down to the millisecond scale. Direct measurement of faster events has been limited to in vitro or invasive recordings. To overcome this limitation, we introduce a new paradigm for transcranial magnetic stimulation. We adjusted the stimulation waveform on the microsecond scale, by varying the duration between the positive and negative phase of the induced electric field, and studied corresponding changes in the elicited motor responses. The magnitude of the electric field needed for given motor-evoked potential amplitude decreased exponentially as a function of this duration with a time constant of 17 µs. Our indirect noninvasive measurement paradigm allows studying neuronal kinetics on the microsecond scale in vivo.


Asunto(s)
Potenciales Evocados Motores/fisiología , Modelos Neurológicos , Corteza Motora/fisiología , Dinámicas no Lineales , Adulto , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Corteza Motora/diagnóstico por imagen , Factores de Tiempo , Estimulación Magnética Transcraneal , Adulto Joven
6.
Brain Topogr ; 30(6): 711-722, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28721533

RESUMEN

Navigated transcranial magnetic stimulation (nTMS) can be applied to locate and outline cortical motor representations. This may be important, e.g., when planning neurosurgery or focused nTMS therapy, or when assessing plastic changes during neurorehabilitation. Conventionally, a cortical location is considered to belong to the motor cortex if the maximum electric field (E-field) targeted there evokes a motor-evoked potential in a muscle. However, the cortex is affected by a broad E-field distribution, which tends to broaden estimates of representation areas by stimulating also the neighboring areas in addition to the maximum E-field location. Our aim was to improve the estimation of nTMS-based motor maps by taking into account the E-field distribution of the stimulation pulse. The effect of the E-field distribution was considered by calculating the minimum-norm estimate (MNE) of the motor representation area. We tested the method on simulated data and then applied it to recordings from six healthy volunteers and one stroke patient. We compared the motor representation areas obtained with the MNE method and a previously introduced interpolation method. The MNE hotspots and centers of gravity were close to those obtained with the interpolation method. The areas of the maps, however, depend on the thresholds used for outlining the areas. The MNE method may improve the definition of cortical motor areas, but its accuracy should be validated by comparing the results with maps obtained with direct cortical stimulation of the cortex where the E-field distribution can be better focused.


Asunto(s)
Mapeo Encefálico/métodos , Potenciales Evocados Motores/fisiología , Modelos Neurológicos , Corteza Motora/fisiología , Estimulación Magnética Transcraneal/métodos , Adulto , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Masculino
7.
Neuroimage ; 139: 157-166, 2016 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-27291496

RESUMEN

Combined transcranial magnetic stimulation (TMS) and electroencephalography (EEG) often suffers from large muscle artifacts. Muscle artifacts can be removed using signal-space projection (SSP), but this can make the visual interpretation of the remaining EEG data difficult. We suggest to use an additional step after SSP that we call source-informed reconstruction (SIR). SSP-SIR improves substantially the signal quality of artifactual TMS-EEG data, causing minimal distortion in the neuronal signal components. In the SSP-SIR approach, we first project out the muscle artifact using SSP. Utilizing an anatomical model and the remaining signal, we estimate an equivalent source distribution in the brain. Finally, we map the obtained source estimate onto the original signal space, again using anatomical information. This approach restores the neuronal signals in the sensor space and interpolates EEG traces onto the completely rejected channels. The introduced algorithm efficiently suppresses TMS-related muscle artifacts in EEG while retaining well the neuronal EEG topographies and signals. With the presented method, we can remove muscle artifacts from TMS-EEG data and recover the underlying brain responses without compromising the readability of the signals of interest.


Asunto(s)
Artefactos , Electroencefalografía/métodos , Potenciales Evocados Motores/fisiología , Corteza Motora/fisiología , Contracción Muscular/fisiología , Músculo Esquelético/fisiología , Estimulación Magnética Transcraneal/métodos , Adulto , Algoritmos , Mapeo Encefálico/métodos , Electromiografía/métodos , Humanos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
8.
Magn Reson Med ; 71(3): 955-65, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23670955

RESUMEN

PURPOSE: For ultra-low-field MRI, the spatial-encoding magnetic fields generated by gradient coils can have strong concomitant fields leading to prominent image distortion. Additionally, using superconducting magnet to pre-polarize magnetization can improve the signal-to-noise ratio of ultra-low-field MRI. Yet the spatially inhomogeneous remanence field due to the permanently trapped flux inside a superconducting pre-polarizing coil modulates magnetization and causes further image distortion. METHOD: We propose a two-stage frequency-space (f-x) formulation to accurately describe the dynamics of spatially-encoded magnetization under the influence of concomitant and remanence fields, which allows for correcting image distortion due to concomitant and remanence fields. RESULTS: Our method is computationally efficient as it uses a combination of the fast Fourier transform algorithm and a linear equation solver. With sufficiently dense discretization in solving the linear equation, the performance of this f-x method was found to be stable among different choices of the regularization parameter and the regularization matrix. CONCLUSION: We present this method together with numerical simulations and experimental data to demonstrate how concomitant and remanence field artifacts in ultra-low-field MRI can be corrected efficiently.


Asunto(s)
Artefactos , Encéfalo/anatomía & histología , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Procesamiento de Señales Asistido por Computador , Algoritmos , Humanos , Imagen por Resonancia Magnética/instrumentación , Fantasmas de Imagen , Dosis de Radiación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
9.
Magn Reson Med ; 69(6): 1795-804, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22807201

RESUMEN

Ultra-low-field MRI uses microtesla fields for signal encoding and sensitive superconducting quantum interference devices for signal detection. Similarly, modern magnetoencephalography (MEG) systems use arrays comprising hundreds of superconducting quantum interference device channels to measure the magnetic field generated by neuronal activity. In this article, hybrid MEG-MRI instrumentation based on a commercial whole-head MEG device is described. The combination of ultra-low-field MRI and MEG in a single device is expected to significantly reduce coregistration errors between the two modalities, to simplify MEG analysis, and to improve MEG localization accuracy. The sensor solutions, MRI coils (including a superconducting polarizing coil), an optimized pulse sequence, and a reconstruction method suitable for hybrid MEG-MRI measurements are described. The performance of the device is demonstrated by presenting ultra-low-field-MR images and MEG recordings that are compared with data obtained with a 3T scanner and a commercial MEG device.


Asunto(s)
Mapeo Encefálico/instrumentación , Encéfalo/anatomía & histología , Encéfalo/fisiología , Imagen por Resonancia Magnética/instrumentación , Magnetoencefalografía/instrumentación , Magnetometría/instrumentación , Técnica de Sustracción/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Integración de Sistemas
10.
Magn Reson Med ; 70(2): 595-600, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23023497

RESUMEN

In ultra-low-field magnetic resonance imaging, arrays of up to hundreds of highly sensitive superconducting quantum interference devices (SQUIDs) can be used to detect the weak magnetic fields emitted by the precessing magnetization. Here, we investigate the noise amplification in sensitivity-encoded ultra-low-field MRI at various acceleration rates using a SQUID array consisting of 102 magnetometers, 102 gradiometers, or 306 magnetometers and gradiometers, to cover the whole head. Our results suggest that SQUID arrays consisting of 102 magnetometers and 102 gradiometers are similar in g-factor distribution. A SQUID array of 306 sensors (102 magnetometers and 204 gradiometers) only marginally improves the g-factor. Corroborating with previous studies, the g-factor in 2D sensitivity-encoded ultra-low-field MRI with 9 to 16-fold 2D accelerations using the SQUID array studied here may be acceptable.


Asunto(s)
Amplificadores Electrónicos , Encéfalo/anatomía & histología , Aumento de la Imagen/instrumentación , Imagen por Resonancia Magnética/instrumentación , Magnetismo/instrumentación , Transductores , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Relación Señal-Ruido
11.
IEEE Trans Biomed Eng ; 70(7): 2025-2034, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37018249

RESUMEN

OBJECTIVE: This work aims for a method to design manufacturable windings for transcranial magnetic stimulation (TMS) coils with fine control over the induced electric field (E-field) distributions. Such TMS coils are required for multi-locus TMS (mTMS). METHODS: We introduce a new mTMS coil design workflow with increased flexibility in target E-field definition and faster computations compared to our previous method. We also incorporate custom current density and E-field fidelity constraints to ensure that the target E-fields are accurately reproduced with feasible winding densities in the resulting coil designs. We validated the method by designing, manufacturing, and characterizing a 2-coil mTMS transducer for focal rat brain stimulation. RESULTS: Applying the constraints reduced the computed maximum surface current densities from 15.4 and 6.6 kA/mm to the target value 4.7 kA/mm, yielding winding paths suitable for a 1.5-mm-diameter wire with 7-kA maximum currents while still replicating the target E-fields with the predefined 2.8% maximum error in the FOV. The optimization time was reduced by two thirds compared to our previous method. CONCLUSION: The developed method allowed us to design a manufacturable, focal 2-coil mTMS transducer for rat TMS impossible to attain with our previous design workflow. SIGNIFICANCE: The presented workflow enables considerably faster design and manufacturing of previously unattainable mTMS transducers with increased control over the induced E-field distribution and winding density, opening new possibilities for brain research and clinical TMS.


Asunto(s)
Encéfalo , Estimulación Magnética Transcraneal , Animales , Ratas , Estimulación Magnética Transcraneal/métodos , Encéfalo/fisiología , Cabeza , Técnicas Estereotáxicas , Transductores
12.
Sci Rep ; 13(1): 8225, 2023 05 22.
Artículo en Inglés | MEDLINE | ID: mdl-37217502

RESUMEN

The analysis of motor evoked potentials (MEPs) generated by transcranial magnetic stimulation (TMS) is crucial in research and clinical medical practice. MEPs are characterized by their latency and the treatment of a single patient may require the characterization of thousands of MEPs. Given the difficulty of developing reliable and accurate algorithms, currently the assessment of MEPs is performed with visual inspection and manual annotation by a medical expert; making it a time-consuming, inaccurate, and error-prone process. In this study, we developed DELMEP, a deep learning-based algorithm to automate the estimation of MEP latency. Our algorithm resulted in a mean absolute error of about 0.5 ms and an accuracy that was practically independent of the MEP amplitude. The low computational cost of the DELMEP algorithm allows employing it in on-the-fly characterization of MEPs for brain-state-dependent and closed-loop brain stimulation protocols. Moreover, its learning ability makes it a particularly promising option for artificial-intelligence-based personalized clinical applications.


Asunto(s)
Aprendizaje Profundo , Corteza Motora , Potenciales Evocados Motores/fisiología , Corteza Motora/fisiología , Estimulación Magnética Transcraneal/métodos , Algoritmos , Electromiografía
13.
Brain Sci ; 13(3)2023 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-36979228

RESUMEN

Coregistration of transcranial magnetic stimulation (TMS) and electroencephalography (EEG) allows non-invasive probing of brain circuits: TMS induces brain activation due to the generation of a properly oriented focused electric field (E-field) using a coil placed on a selected position over the scalp, while EEG captures the effects of the stimulation on brain electrical activity. Moreover, the combination of these techniques allows the investigation of several brain properties, including brain functional connectivity. The choice of E-field parameters, such as intensity, orientation, and position, is crucial for eliciting cortex-specific effects. Here, we evaluated whether and how the spatial pattern, i.e., topography and strength of functional connectivity, is modulated by the stimulus orientation. We systematically altered the E-field orientation when stimulating the left pre-supplementary motor area and showed an increase of functional connectivity in areas associated with the primary motor cortex and an E-field orientation-specific modulation of functional connectivity intensity.

15.
Brain Stimul ; 15(2): 306-315, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35038592

RESUMEN

BACKGROUND: Transcranial magnetic stimulation (TMS) coils allow only a slow, mechanical adjustment of the stimulating electric field (E-field) orientation in the cerebral tissue. Fast E-field control is needed to synchronize the stimulation with the ongoing brain activity. Also, empirical models that fully describe the relationship between evoked responses and the stimulus orientation and intensity are still missing. OBJECTIVE: We aimed to (1) develop a TMS transducer for manipulating the E-field orientation electronically with high accuracy at the neuronally meaningful millisecond-level time scale and (2) devise and validate a physiologically based model describing the orientation selectivity of neuronal excitability. METHODS: We designed and manufactured a two-coil TMS transducer. The coil windings were computed with a minimum-energy optimization procedure, and the transducer was controlled with our custom-made electronics. The electronic E-field control was verified with a TMS characterizer. The motor evoked potential amplitude and latency of a hand muscle were mapped in 3° steps of the stimulus orientation in 16 healthy subjects for three stimulation intensities. We fitted a logistic model to the motor response amplitude. RESULTS: The two-coil TMS transducer allows one to manipulate the pulse orientation accurately without manual coil movement. The motor response amplitude followed a logistic function of the stimulus orientation; this dependency was strongly affected by the stimulus intensity. CONCLUSION: The developed electronic control of the E-field orientation allows exploring new stimulation paradigms and probing neuronal mechanisms. The presented model helps to disentangle the neuronal mechanisms of brain function and guide future non-invasive stimulation protocols.


Asunto(s)
Potenciales Evocados Motores , Estimulación Magnética Transcraneal , Electrónica , Humanos , Músculo Esquelético , Neuronas , Estimulación Magnética Transcraneal/métodos
16.
Brain Stimul ; 15(2): 523-531, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35337598

RESUMEN

BACKGROUND: Transcranial magnetic stimulation (TMS) is widely used in brain research and treatment of various brain dysfunctions. However, the optimal way to target stimulation and administer TMS therapies, for example, where and in which electric field direction the stimuli should be given, is yet to be determined. OBJECTIVE: To develop an automated closed-loop system for adjusting TMS parameters (in this work, the stimulus orientation) online based on TMS-evoked brain activity measured with electroencephalography (EEG). METHODS: We developed an automated closed-loop TMS-EEG set-up. In this set-up, the stimulus parameters are electronically adjusted with multi-locus TMS. As a proof of concept, we developed an algorithm that automatically optimizes the stimulation orientation based on single-trial EEG responses. We applied the algorithm to determine the electric field orientation that maximizes the amplitude of the TMS-EEG responses. The validation of the algorithm was performed with six healthy volunteers, repeating the search twenty times for each subject. RESULTS: The validation demonstrated that the closed-loop control worked as desired despite the large variation in the single-trial EEG responses. We were often able to get close to the orientation that maximizes the EEG amplitude with only a few tens of pulses. CONCLUSION: Optimizing stimulation with EEG feedback in a closed-loop manner is feasible and enables effective coupling to brain activity.


Asunto(s)
Electroencefalografía , Estimulación Magnética Transcraneal , Encéfalo/fisiología , Mapeo Encefálico , Retroalimentación , Humanos
17.
Open Res Eur ; 2: 45, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36035767

RESUMEN

Background: Spontaneous cortical oscillations have been shown to modulate cortical responses to transcranial magnetic stimulation (TMS). However, whether these oscillations influence cortical effective connectivity is largely unknown. We conducted a pilot study to set the basis for addressing how spontaneous oscillations affect cortical effective connectivity measured through TMS-evoked potentials (TEPs). Methods: We applied TMS to the left primary motor cortex and right pre-supplementary motor area of three subjects while recording EEG. We classified trials off-line into positive- and negative-phase classes according to the mu and beta rhythms. We calculated differences in the global mean-field amplitude (GMFA) and compared the cortical spreading of the TMS-evoked activity between the two classes. Results: Phase affected the GMFA in four out of 12 datasets (3 subjects × 2 stimulation sites × 2 frequency bands). Two of the observed significant intervals were before 50 ms, two between 50 and 100 ms, and one after 100 ms post-stimulus. Source estimates showed complex spatial differences between the classes in the cortical spreading of the TMS-evoked activity. Conclusions: TMS-evoked effective connectivity seems to depend on the phase of local cortical oscillations at the stimulated site. This work paves the way to design future closed-loop stimulation paradigms.

18.
Front Neurosci ; 16: 935268, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36440290

RESUMEN

Transcranial magnetic stimulation (TMS) is widely applied on humans for research and clinical purposes. TMS studies on small animals, e.g., rodents, can provide valuable knowledge of the underlying neurophysiological mechanisms. Administering TMS on small animals is, however, prone to technical difficulties, mainly due to their small head size. In this study, we aimed to develop an energy-efficient coil and a compatible experimental set-up for administering TMS on rodents. We applied a convex optimization process to develop a minimum-energy coil for TMS on rats. As the coil windings of the optimized coil extend to a wide region, we designed and manufactured a holder on which the rat lies upside down, with its head supported by the coil. We used the set-up to record TMS-electromyography, with electromyography recorded from limb muscles with intramuscular electrodes. The upside-down placement of the rat allowed the operator to easily navigate the TMS without the coil blocking their field of view. With this paradigm, we obtained consistent motor evoked potentials from all tested animals.

19.
J Neural Eng ; 19(6)2022 12 16.
Artículo en Inglés | MEDLINE | ID: mdl-36541458

RESUMEN

Objective.Transcranial magnetic stimulation (TMS) induces an electric field (E-field) in the cortex. To facilitate stimulation targeting, image-guided neuronavigation systems have been introduced. Such systems track the placement of the coil with respect to the head and visualize the estimated cortical stimulation location on an anatomical brain image in real time. The accuracy and precision of the neuronavigation is affected by multiple factors. Our aim was to analyze how different factors in TMS neuronavigation affect the accuracy and precision of the coil-head coregistration and the estimated E-field.Approach.By performing simulations, we estimated navigation errors due to distortions in magnetic resonance images (MRIs), head-to-MRI registration (landmark- and surface-based registrations), localization and movement of the head tracker, and localization of the coil tracker. We analyzed the effect of these errors on coil and head coregistration and on the induced E-field as determined with simplistic and realistic head models.Main results.Average total coregistration accuracies were in the range of 2.2-3.6 mm and 1°; precision values were about half of the accuracy values. The coregistration errors were mainly due to head-to-MRI registration with average accuracies 1.5-1.9 mm/0.2-0.4° and precisions 0.5-0.8 mm/0.1-0.2° better with surface-based registration. The other major source of error was the movement of the head tracker with average accuracy of 1.5 mm and precision of 1.1 mm. When assessed within an E-field method, the average accuracies of the peak E-field location, orientation, and magnitude ranged between 1.5 and 5.0 mm, 0.9 and 4.8°, and 4.4 and 8.5% across the E-field models studied. The largest errors were obtained with the landmark-based registration. When computing another accuracy measure with the most realistic E-field model as a reference, the accuracies tended to improve from about 10 mm/15°/25% to about 2 mm/2°/5% when increasing realism of the E-field model.Significance.The results of this comprehensive analysis help TMS operators to recognize the main sources of error in TMS navigation and that the coregistration errors and their effect in the E-field estimation depend on the methods applied. To ensure reliable TMS navigation, we recommend surface-based head-to-MRI registration and realistic models for E-field computations.


Asunto(s)
Encéfalo , Estimulación Magnética Transcraneal , Estimulación Magnética Transcraneal/métodos , Encéfalo/fisiología , Mapeo Encefálico/métodos , Cabeza , Neuronavegación/métodos , Imagen por Resonancia Magnética/métodos
20.
Brain Stimul ; 15(1): 116-124, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34818580

RESUMEN

BACKGROUND: Transcranial magnetic stimulation (TMS) allows non-invasive stimulation of the cortex. In multi-locus TMS (mTMS), the stimulating electric field (E-field) is controlled electronically without coil movement by adjusting currents in the coils of a transducer. OBJECTIVE: To develop an mTMS system that allows adjusting the location and orientation of the E-field maximum within a cortical region. METHODS: We designed and manufactured a planar 5-coil mTMS transducer to allow controlling the maximum of the induced E-field within a cortical region approximately 30 mm in diameter. We developed electronics with a design consisting of independently controlled H-bridge circuits to drive up to six TMS coils. To control the hardware, we programmed software that runs on a field-programmable gate array and a computer. To induce the desired E-field in the cortex, we developed an optimization method to calculate the currents needed in the coils. We characterized the mTMS system and conducted a proof-of-concept motor-mapping experiment on a healthy volunteer. In the motor mapping, we kept the transducer placement fixed while electronically shifting the E-field maximum on the precentral gyrus and measuring electromyography from the contralateral hand. RESULTS: The transducer consists of an oval coil, two figure-of-eight coils, and two four-leaf-clover coils stacked on top of each other. The technical characterization indicated that the mTMS system performs as designed. The measured motor evoked potential amplitudes varied consistently as a function of the location of the E-field maximum. CONCLUSION: The developed mTMS system enables electronically targeted brain stimulation within a cortical region.


Asunto(s)
Corteza Motora , Estimulación Magnética Transcraneal , Electromiografía/métodos , Potenciales Evocados Motores , Humanos , Corteza Motora/fisiología , Técnicas Estereotáxicas , Estimulación Magnética Transcraneal/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA