RESUMEN
OBJECTIVES: Minimal residual disease status in multiple myeloma is an important prognostic biomarker. Recently, personalized blood-based targeted mass spectrometry (MS-MRD) was shown to provide a sensitive and minimally invasive alternative to measure minimal residual disease. However, quantification of MS-MRD requires a unique calibrator for each patient. The use of patient-specific stable isotope labelled (SIL) peptides is relatively costly and time-consuming, thus hindering clinical implementation. Here, we introduce a simplification of MS-MRD by using an off-the-shelf calibrator. METHODS: SILuMAB-based MS-MRD was performed by spiking a monoclonal stable isotope labeled IgG, SILuMAB-K1, in the patient serum. The abundance of both M-protein-specific peptides and SILuMAB-specific peptides were monitored by mass spectrometry. The relative ratio between M-protein peptides and SILuMAB peptides allowed for M-protein quantification. We assessed linearity, sensitivity and reproducibility of SILuMAB-based MS-MRD in longitudinally collected sera from the IFM-2009 clinical trial. RESULTS: A linear dynamic range was achieved of over 5 log scales, allowing for M-protein quantification down to 0.001â¯g/L. The inter-assay CV of SILuMAB-based MS-MRD was on average 11â¯%. Excellent concordance between SIL- and SILuMAB-based MS-MRD was shown (R2>0.985). Additionally, signal intensity of spiked SILuMAB can be used for quality control purpose to assess system performance and incomplete SILuMAB digestion can be used as quality control for sample preparation. CONCLUSIONS: Compared to SIL peptides, SILuMAB-based MS-MRD improves the reproducibility, turn-around-times and cost-efficacy of MS-MRD without diminishing its sensitivity and specificity. Furthermore, SILuMAB can be used as a MS-MRD quality control tool to monitor sample preparation efficacy and assay performance.
Asunto(s)
Mieloma Múltiple , Humanos , Mieloma Múltiple/diagnóstico , Neoplasia Residual , Reproducibilidad de los Resultados , Espectrometría de Masas/métodos , Péptidos , IsótoposRESUMEN
OBJECTIVES: Minimal residual disease (MRD) status in multiple myeloma (MM) is an important prognostic biomarker. Personalized blood-based targeted mass spectrometry detecting M-proteins (MS-MRD) was shown to provide a sensitive and minimally invasive alternative to MRD-assessment in bone marrow. However, MS-MRD still comprises of manual steps that hamper upscaling of MS-MRD testing. Here, we introduce a proof-of-concept for a novel workflow using data independent acquisition-parallel accumulation and serial fragmentation (dia-PASEF) and automated data processing. METHODS: Using automated data processing of dia-PASEF measurements, we developed a workflow that identified unique targets from MM patient sera and personalized protein sequence databases. We generated patient-specific libraries linked to dia-PASEF methods and subsequently quantitated and reported M-protein concentrations in MM patient follow-up samples. Assay performance of parallel reaction monitoring (prm)-PASEF and dia-PASEF workflows were compared and we tested mixing patient intake sera for multiplexed target selection. RESULTS: No significant differences were observed in lowest detectable concentration, linearity, and slope coefficient when comparing prm-PASEF and dia-PASEF measurements of serial dilutions of patient sera. To improve assay development times, we tested multiplexing patient intake sera for target selection which resulted in the selection of identical clonotypic peptides for both simplex and multiplex dia-PASEF. Furthermore, assay development times improved up to 25× when measuring multiplexed samples for peptide selection compared to simplex. CONCLUSIONS: Dia-PASEF technology combined with automated data processing and multiplexed target selection facilitated the development of a faster MS-MRD workflow which benefits upscaling and is an important step towards the clinical implementation of MS-MRD.
Asunto(s)
Mieloma Múltiple , Neoplasia Residual , Flujo de Trabajo , Humanos , Mieloma Múltiple/diagnóstico , Mieloma Múltiple/sangre , Neoplasia Residual/diagnóstico , Ensayos Analíticos de Alto Rendimiento/métodos , Medicina de Precisión/métodos , AutomatizaciónRESUMEN
OBJECTIVES: Multiple myeloma (MM) is a plasma cell malignancy characterized by a monoclonal expansion of plasma cells that secrete a characteristic M-protein. This M-protein is crucial for diagnosis and monitoring of MM in the blood of patients. Recent evidence has emerged suggesting that N-glycosylation of the M-protein variable (Fab) region contributes to M-protein pathogenicity, and that it is a risk factor for disease progression of plasma cell disorders. Current methodologies lack the specificity to provide a site-specific glycoprofile of the Fab regions of M-proteins. Here, we introduce a novel glycoproteogenomics method that allows detailed M-protein glycoprofiling by integrating patient specific Fab region sequences (genomics) with glycoprofiling by glycoproteomics. METHODS: Glycoproteogenomics was used for the detailed analysis of de novo N-glycosylation sites of M-proteins. First, Genomic analysis of the M-protein variable region was used to identify de novo N-glycosylation sites. Subsequently glycopeptide analysis with LC-MS/MS was used for detailed analysis of the M-protein glycan sites. RESULTS: Genomic analysis uncovered a more than two-fold increase in the Fab Light Chain N-glycosylation of M-proteins of patients with Multiple Myeloma compared to Fab Light Chain N-glycosylation of polyclonal antibodies from healthy individuals. Subsequent glycoproteogenomics analysis of 41 patients enrolled in the IFM 2009 clinical trial revealed that the majority of the Fab N-glycosylation sites were fully occupied with complex type glycans, distinguishable from Fc region glycans due to high levels of sialylation, fucosylation and bisecting structures. CONCLUSIONS: Together, glycoproteogenomics is a powerful tool to study de novo Fab N-glycosylation in plasma cell dyscrasias.
Asunto(s)
Mieloma Múltiple , Humanos , Mieloma Múltiple/metabolismo , Mieloma Múltiple/genética , Mieloma Múltiple/diagnóstico , Glicosilación , Proteómica/métodos , Espectrometría de Masas en Tándem , Glicoproteínas/metabolismo , Cromatografía Liquida , Proteínas de Mieloma/metabolismo , Proteínas de Mieloma/análisisRESUMEN
Multiple myeloma (MM) is characterized by the clonal expansion of plasma cells and the excretion of a monoclonal immunoglobulin (M-protein), or fragments thereof. This biomarker plays a key role in the diagnosis and monitoring of MM. Although there is currently no cure for MM, novel treatment modalities such as bispecific antibodies and CAR T-cell therapies have led to substantial improvement in survival. With the introduction of several classes of effective drugs, an increasing percentage of patients achieve a complete response. This poses new challenges to traditional electrophoretic and immunochemical M-protein diagnostics because these methods lack sensitivity to monitor minimal residual disease (MRD). In 2016, the International Myeloma Working Group (IMWG) expanded their disease response criteria with bone marrow-based MRD assessment using flow cytometry or next-generation sequencing in combination with imaging-based disease monitoring of extramedullary disease. MRD status is an important independent prognostic marker and its potential as a surrogate endpoint for progression-free survival is currently being studied. In addition, numerous clinical trials are investigating the added clinical value of MRD-guided therapy decisions in individual patients. Because of these novel clinical applications, repeated MRD evaluation is becoming common practice in clinical trials as well as in the management of patients outside clinical trials. In response to this, novel mass spectrometric methods that have been developed for blood-based MRD monitoring represent attractive minimally invasive alternatives to bone marrow-based MRD evaluation. This paves the way for dynamic MRD monitoring to allow the detection of early disease relapse, which may prove to be a crucial factor in facilitating future clinical implementation of MRD-guided therapy. This review provides an overview of state-of-the-art of MRD monitoring, describes new developments and applications of blood-based MRD monitoring, and suggests future directions for its successful integration into the clinical management of MM patients.
RESUMEN
BACKGROUND: Minimal residual disease (MRD) status assessed on bone marrow aspirates is a major prognostic biomarker in multiple myeloma (MM). In this study we evaluated blood-based targeted mass spectrometry (MS-MRD) as a sensitive, minimally invasive alternative to measure MM disease activity. METHODS: Therapy response of 41 MM patients in the IFM-2009 clinical trial (NCT01191060) was assessed with MS-MRD on frozen sera and compared to routine state-of-the-art monoclonal protein (M-protein) diagnostics and next-generation sequencing (NGS-MRD) at 2 time points. RESULTS: In all 41 patients we were able to identify clonotypic M-protein-specific peptides and perform serum-based MS-MRD measurements. MS-MRD is significantly more sensitive to detect M-protein compared to either electrophoretic M-protein diagnostics or serum free light chain analysis. The concordance between NGS-MRD and MS-MRD status in 81 paired bone marrow/sera samples was 79%. The 50% progression-free survival (PFS) was identical (49 months) for patients who were either NGS-positive or MS-positive directly after maintenance treatment. The 50% PFS was 69 and 89 months for NGS-negative and MS-negative patients, respectively. The longest 50% PFS (96 months) was observed in patients who were MRD-negative for both methods. MS-MRD relapse during maintenance treatment was significantly correlated to poor PFS (P < 0.0001). CONCLUSIONS: Our data indicate proof-of-principle that MS-MRD evaluation in blood is a feasible, patient friendly alternative to NGS-MRD assessed on bone marrow. Clinical validation of the prognostic value of MS-MRD and its complementary value in MRD-evaluation of patients with MM is warranted in an independent larger cohort.
Asunto(s)
Mieloma Múltiple , Médula Ósea/metabolismo , Secuenciación de Nucleótidos de Alto Rendimiento/métodos , Humanos , Espectrometría de Masas , Mieloma Múltiple/diagnóstico , Mieloma Múltiple/tratamiento farmacológico , Mieloma Múltiple/genética , Neoplasia Residual/diagnósticoRESUMEN
OBJECTIVES: The therapeutic monoclonal antibody (t-mAb) daratumumab, used to treat multiple myeloma (MM) patients, interferes with routine, electrophoretic based M-protein diagnostics. Electrophoretic response assessment becomes increasingly difficult when multiple t-mAbs are combined for use in a single patient. This is the first study to address the analytical challenges of M-protein monitoring when multiple t-mAbs are combined. METHODS: In this proof-of-principle study we evaluate two different methods to monitor M-protein responses in three MM patients, who receive both daratumumab and nivolumab. The double hydrashift assay aims to resolve t-mAb interference on immunofixation. The MS-MRD (mass spectrometry minimal residual disease) assay measures clonotypic peptides to quantitate both M-protein and t-mAb concentrations. RESULTS: After exposure to daratumumab and nivolumab, both t-mAbs become visible on immunofixation electrophoresis (IFE) as two IgG-kappa bands that migrate close to each other at the cathodal end of the γ-region. In case the M-protein co-migrates with these t-mAbs, the observed interference was completely abolished with the double IFE hydrashift assay. In all three patients the MS-MRD assay was also able to distinguish the M-protein from the t-mAbs. Additional advantage of the MS-MRD assay is that this multiplex assay is more sensitive and allows quantitative M-protein-, daratumumab- and nivolumab-monitoring. CONCLUSIONS: Daratumumab and nivolumab interfere with electrophoretic M-protein diagnostics. However, the M-protein can be distinguished from both t-mAbs by use of a double hydrashift assay. The MS-MRD assay provides an alternative method that allows sensitive and simultaneous quantitative monitoring of both the M-protein and t-mAbs.