Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
2.
Cell Chem Biol ; 31(2): 349-360.e6, 2024 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-37858335

RESUMEN

As a key regulator of the innate immune system, the NLRP3 inflammasome responds to a variety of environmental insults through activation of caspase-1 and release of the proinflammatory cytokines IL-1ß and IL-18. Aberrant NLRP3 inflammasome function is implicated in numerous inflammatory diseases, spurring drug discovery efforts at NLRP3 as a therapeutic target. A diverse array of small molecules is undergoing preclinical/clinical evaluation with a reported mode of action involving direct modulation of the NLRP3 pathway. However, for a subset of these ligands the functional link between live-cell target engagement and pathway inhibition has yet to be fully established. Herein we present a cohort of mechanistic assays to both query direct NLRP3 engagement in cells, and functionally interrogate different nodes of NLRP3 pathway activity. This system enabled the stratification of potency for five confirmed NLRP3 inhibitors, and identification of two reported NLRP3 inhibitors that failed to demonstrate direct pathway antagonism.


Asunto(s)
Inflamasomas , Proteína con Dominio Pirina 3 de la Familia NLR , Humanos , Inflamasomas/metabolismo , Proteína con Dominio Pirina 3 de la Familia NLR/metabolismo , Citocinas/metabolismo , Interleucina-1beta/metabolismo
3.
Methods Mol Biol ; 2612: 195-224, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36795369

RESUMEN

Traditional immunoassays to detect secreted or intracellular proteins can be tedious, require multiple washing steps, and are not easily adaptable to a high-throughput screening (HTS) format. To overcome these limitations, we developed Lumit, a novel immunoassay approach that combines bioluminescent enzyme subunit complementation technology and immunodetection. This bioluminescent immunoassay does not require washes or liquid transfers and takes less than 2 h to complete in a homogeneous "Add and Read" format. In this chapter, we describe step-by-step protocols to create Lumit immunoassays for the detection of (1) secreted cytokines from cells, (2) phosphorylation levels of a specific signaling pathway node protein, and (3) a biochemical protein-protein interaction between a viral surface protein and its human receptor.


Asunto(s)
Citocinas , Pruebas Inmunológicas , Humanos , Inmunoensayo/métodos
4.
Anal Biochem ; 387(2): 294-302, 2009 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-19454251

RESUMEN

A luminescent method to individually measure the chymotrypsin-like, trypsin-like, or caspase-like activities of the proteasome in cultured cells was developed. Each assay uses a specific luminogenic peptide substrate in a buffer optimized for cell permeabilization, proteasome activity, and luciferase activity. Luminescence is generated in a coupled-enzyme format in which proteasome cleavage of the peptide conjugated substrate generates aminoluciferin, which is a substrate for luciferase. The homogeneous method eliminates the need to prepare individual cell extracts as samples. Luminogenic proteasome substrates and buffer formulations enabled development of a single reagent addition method with adequate sensitivity for 96- and 384-well plate formats. Proteasome trypsin-like specificity was enhanced by incorporating a mixture of protease inhibitors that significantly reduce nonspecific serum and cellular backgrounds. The assays were used to determine EC(50) values for the specific proteasome inhibitors epoxomicin and bortezomib for each of the catalytic sites using a variety of cancer lines. These cell-based proteasome assays are direct, simple, and sensitive, making them ideal for high-throughput screening.


Asunto(s)
Mediciones Luminiscentes , Complejo de la Endopetidasa Proteasomal/metabolismo , Caspasas/metabolismo , Células Cultivadas , Fluorescencia , Humanos
5.
Methods Mol Biol ; 414: 163-81, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18175819

RESUMEN

Protein degradation is mediated predominantly through the ubiquitin-proteasome pathway. The importance of the proteasome in regulating degradation of proteins involved in cell-cycle control, apoptosis, and angiogenesis led to the recognition of the proteasome as a therapeutic target for cancer . The importance of the proteasome for general cell homeostasis has been established, and the 2004 Nobel Prize for Chemistry honored the researchers that discovered the ubiquitin-proteasome pathway. Robust, sensitive assays are essential for monitoring proteasome activity and for developing inhibitors of the proteasome. Peptide-conjugated fluorophores are widely used as substrates for monitoring proteasome activity, but fluorogenic substrates can exhibit significant background and can be problematic for screening because of cellular autoflorescence or fluorescent library compounds. To address these issues, we developed a homogeneous, bioluminescent method that combines peptide-conjugated aminoluciferin substrates and a stabilized luciferase. We have developed homogeneous, bioluminescent assays for all three proteasome activities, the chymotrypsin-like, trypsin-like, and caspase-like, using purified proteasome. We have also applied this technology to a cellular assay using the substrate for the chymotrypsin-like activity in combination with a selective membrane permeabilization step (patent pending). The proteasome assays are designed in a simple "add and read" format and have been tested in 96-and 384-well plates. The bioluminescent, coupled-enzyme format enables sensitive and rapid protease assays ideal for inhibitor screening.


Asunto(s)
Proteínas Luminiscentes/análisis , Complejo de la Endopetidasa Proteasomal/química , Células Cultivadas , Técnicas de Laboratorio Clínico , Humanos , Proteínas Luminiscentes/química , Modelos Biológicos , Complejo de la Endopetidasa Proteasomal/metabolismo , Complejo de la Endopetidasa Proteasomal/fisiología , Transducción de Señal , Ubiquitina/fisiología
6.
Expert Opin Drug Metab Toxicol ; 4(1): 103-20, 2008 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-18370862

RESUMEN

Bioluminescent assays couple a limiting component of a luciferase-catalyzed photon-emitting reaction to a variable parameter of interest, while holding the other components constant or non-limiting. In this way light output varies with the parameter of interest. This review describes three bioluminescent assay types that use firefly luciferase to measure properties of drugs and other xenobiotics which affect their absorption, distribution, metabolism, elimination and toxicity. First, levels of the luciferase enzyme itself are measured in gene reporter assays that place a luciferase cDNA under the control of regulatory sequences from ADMET-related genes. This approach identifies activators of nuclear receptors that regulate expression of genes encoding drug-metabolizing enzymes and drug transporters. Second, drug effects on enzyme activities are monitored with luminogenic probe substrates that are inactive derivatives of the luciferase substrate luciferin. The enzymes of interest convert the substrates to free luciferin, which is detected in a second reaction with luciferase. This approach is used with the drug-metabolizing CYP and monoamine oxidase enzymes, apoptosis-associated caspase proteases, a marker protease for non-viable cells and with glutathione-S-transferase to measure glutathione levels in cell lysates. Third, ATP concentration is monitored as a marker of cell viability or cell death and as a way of identifying substrates for the ATP-dependent drug transporter, P-glycoprotein. Luciferase activity is measured in the presence of a sample that supplies the requisite luciferase substrate, ATP, so that light output varies with ATP concentration. The bioluminescent ADMET assays are rapid and sensitive, amenable to automated high-throughput applications and offer significant advantages over alternative methods.


Asunto(s)
Luminiscencia , Preparaciones Farmacéuticas/metabolismo , Adenosina Trifosfatasas/metabolismo , Adenosina Trifosfato/metabolismo , Animales , Caspasas/química , Caspasas/metabolismo , Supervivencia Celular/efectos de los fármacos , Sistema Enzimático del Citocromo P-450/metabolismo , Glutatión/metabolismo , Humanos , Luciferasas/análisis , Luciferasas/metabolismo , Oxigenasas de Función Mixta/análisis , Oxigenasas de Función Mixta/metabolismo , Farmacocinética
7.
J Immunol Methods ; 447: 1-13, 2017 08.
Artículo en Inglés | MEDLINE | ID: mdl-28268194

RESUMEN

Inflammasomes are protein complexes induced by diverse inflammatory stimuli that activate caspase-1, resulting in the processing and release of cytokines, IL-1ß and IL-18, and pyroptosis, an immunogenic form of cell death. To provide a homogeneous method for detecting caspase-1 activity, we developed a bioluminescent, plate-based assay that combines a substrate, Z-WEHD-aminoluciferin, with a thermostable luciferase in an optimized lytic reagent added directly to cultured cells. Assay specificity for caspase-1 is conferred by inclusion of a proteasome inhibitor in the lytic reagent and by use of a caspase-1 inhibitor to confirm activity. This approach enables a specific and rapid determination of caspase-1 activation. Caspase-1 activity is stable in the reagent thereby providing assay convenience and flexibility. Using this assay system, caspase-1 activation has been determined in THP-1 cells following treatment with α-hemolysin, LPS, nigericin, gramicidin, MSU, R848, Pam3CSK4, and flagellin. Caspase-1 activation has also been demonstrated in treated J774A.1 mouse macrophages, bone marrow-derived macrophages (BMDMs) from mice, as well as in human primary monocytes. Caspase-1 activity was not detected in treated BMDMs derived from Casp1-/- mice, further confirming the specificity of the assay. Caspase-1 activity can be measured directly in cultured cells using the lytic reagent, or caspase-1 activity released into medium can be monitored by assay of transferred supernatant. The caspase-1 assay can be multiplexed with other assays to monitor additional parameters from the same cells, such as IL-1ß release or cell death. The caspase-1 assay in combination with a sensitive real-time monitor of cell death allows one to accurately establish pyroptosis. This assay system provides a rapid, convenient, and flexible method to specifically and quantitatively monitor caspase-1 activation in cells in a plate-based format. This will allow a more efficient and effective assessment of inflammasome activation as well as enable high-throughput screening for inflammasome modulators.


Asunto(s)
Caspasa 1/metabolismo , Inflamasomas/metabolismo , Mediciones Luminiscentes/métodos , Monocitos/metabolismo , Animales , Línea Celular , Activación Enzimática , Humanos , Luciferasas/metabolismo , Mediciones Luminiscentes/instrumentación , Macrófagos/efectos de los fármacos , Macrófagos/metabolismo , Ratones , Monocitos/enzimología , Piroptosis , Sensibilidad y Especificidad
8.
J Biomol Screen ; 10(2): 137-48, 2005 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-15799957

RESUMEN

Using caspase-3 as a model, the authors have developed a strategy for highly sensitive, homogeneous protease assays suitable for high-throughput, automated applications. The assay uses peptide-conjugated aminoluciferin as the protease substrate and a firefly luciferase that has been molecularly evolved for increased stability. By combining the proluminescent caspase-3 substrate, Z-DEVD-aminoluciferin, with a stabilized luciferase in a homogeneous format, the authors developed an assay that is significantly faster and more sensitive than fluorescent caspase-3 assays. The assay has a single-step format, in which protease cleavage of the substrate and luciferase oxidation of the aminoluciferin occurs simultaneously. Because these processes are coupled, they rapidly achieve steady state to maintain stable luminescence for several hours. Maximum sensitivity is attained when this steady state occurs; consequently, this coupled-enzyme system results in a very rapid assay. The homogeneous format inherently removes trace contamination by free aminoluciferin, resulting in extremely low background and yielding exceptionally high signal-to-noise ratios and excellent Z' factors. Another advantage of a luminescent format is that it avoids problems of cell autofluorescence or fluorescence interference that can be associated with synthetic chemical and natural product libraries. This bioluminescent, homogeneous format should be widely applicable to other protease assays.


Asunto(s)
Caspasas/metabolismo , Mediciones Luminiscentes/métodos , Modelos Biológicos , Caspasa 3 , Línea Celular Tumoral , Dimetilsulfóxido , Fluorescencia , Humanos , Concentración 50 Inhibidora , Estructura Molecular , Sensibilidad y Especificidad
9.
Methods Mol Biol ; 1219: 95-114, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25308265

RESUMEN

Protein degradation is mediated predominantly through the ubiquitin-proteasome pathway. The importance of the proteasome in regulating degradation of proteins involved in cell-cycle control, apoptosis, and angiogenesis led to the recognition of the proteasome as a therapeutic target for cancer. The proteasome is also essential for degrading misfolded and aberrant proteins, and impaired proteasome function has been implicated in neurodegerative and cardiovascular diseases. Robust, sensitive assays are essential for monitoring proteasome activity and for developing inhibitors of the proteasome. Peptide-conjugated fluorophores are widely used as substrates for monitoring proteasome activity, but fluorogenic substrates can exhibit significant background and can be problematic for screening because of cellular autofluorescence or interference from fluorescent library compounds. Furthermore, fluorescent proteasome assays require column-purified 20S or 26S proteasome (typically obtained from erythrocytes), or proteasome extracts from whole cells, as their samples. To provide assays more amenable to high-throughput screening, we developed a homogeneous, bioluminescent method that combines peptide-conjugated aminoluciferin substrates and a stabilized luciferase. Using substrates for the chymotrypsin-like, trypsin-like, and caspase-like proteasome activities in combination with a selective membrane permeabilization step, we developed single-step, cell-based assays to measure each of the proteasome catalytic activities. The homogeneous method eliminates the need to prepare individual cell extracts as samples and has adequate sensitivity for 96- and 384-well plates. The simple "add and read" format enables sensitive and rapid proteasome assays ideal for inhibitor screening.


Asunto(s)
Mediciones Luminiscentes/métodos , Complejo de la Endopetidasa Proteasomal/metabolismo , Animales , Caspasas/metabolismo , Extractos Celulares , Humanos , Luciferasas/química , Mediciones Luminiscentes/instrumentación , Complejo de la Endopetidasa Proteasomal/análisis , Complejo de la Endopetidasa Proteasomal/aislamiento & purificación
10.
Biotechniques ; 51(2): 105-10, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21806554

RESUMEN

A bioluminescent general protease assay was developed using a combination of five luminogenic peptide substrates. The peptide-conjugated luciferin substrates were combined with luciferase to form a homogeneous, coupled-enzyme assay. This single-reagent format minimized backgrounds, gave stable signals, and reached peak sensitivity within 30 min. The bioluminescent assay was used to detect multiple proteases representing serine, cysteine, and metalloproteinase classes. The range of proteases detected was broader and the sensitivity greater, when compared with a standard fluorescent assay based on cleavage of the whole protein substrate casein. Fifteen of twenty proteases tested had signal-to-background ratios >10 with the bioluminescent method, compared with only seven proteases with the fluorescent approach. The bioluminescent assay also achieved lower detection limits (≤100 pg) than fluorescent methods. During protein purification processes, especially for therapeutic proteins, even trace levels of contamination can impact the protein's stability and activity. This sensitive, bioluminescent, protease assay should be useful for applications in which contaminating proteases are detrimental and protein purity is essential.


Asunto(s)
Luciferina de Luciérnaga/análogos & derivados , Colorantes Fluorescentes/metabolismo , Luciferasas de Luciérnaga/metabolismo , Mediciones Luminiscentes/métodos , Péptido Hidrolasas/análisis , Caseínas/química , Caseínas/metabolismo , Luciferina de Luciérnaga/metabolismo , Sustancias Luminiscentes/química , Modelos Químicos , Oligopéptidos/metabolismo , Péptido Hidrolasas/clasificación , Péptido Hidrolasas/metabolismo , Proteínas Recombinantes/normas , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA