Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Sensors (Basel) ; 23(21)2023 Oct 28.
Artículo en Inglés | MEDLINE | ID: mdl-37960497

RESUMEN

Heart diseases rank among the most fatal health concerns globally, with the majority being preventable through early diagnosis and effective treatment. Electrocardiogram (ECG) analysis is critical in detecting heart diseases, as it captures the heart's electrical activities. For continuous monitoring, wearable electrocardiographic devices must ensure user comfort over extended periods, typically 24 to 48 h. These devices demand specialized algorithms with low computational complexity to accommodate memory and power consumption constraints. One of the most crucial aspects of ECG signals is accurately detecting heartbeat intervals, specifically the R peaks. In this study, we introduce a novel algorithm designed for wearable devices, offering two primary attributes: robustness against noise and low computational complexity. Our algorithm entails fitting a least-squares parabola to the ECG signal and adaptively shaping it as it sweeps through the signal. Notably, our proposed algorithm eliminates the need for band-pass filters, which can inadvertently smooth the R peaks, making them more challenging to identify. We compared the algorithm's performance using two extensive databases: the meta-database QT database and the BIH-MIT database. Importantly, our method does not necessitate the precise localization of the ECG signal's isoelectric line, contributing to its low computational complexity. In the analysis of the QT database, our algorithm demonstrated a substantial advantage over the classical Pan-Tompkins algorithm and maintained competitiveness with state-of-the-art approaches. In the case of the BIH-MIT database, the performance results were more conservative; they continued to underscore the real-world utility of our algorithm in clinical contexts.


Asunto(s)
Cardiopatías , Dispositivos Electrónicos Vestibles , Humanos , Procesamiento de Señales Asistido por Computador , Electrocardiografía/métodos , Algoritmos
2.
Sensors (Basel) ; 22(5)2022 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-35270994

RESUMEN

In this paper, we addressed the problem of dataset scarcity for the task of network intrusion detection. Our main contribution was to develop a framework that provides a complete process for generating network traffic datasets based on the aggregation of real network traces. In addition, we proposed a set of tools for attribute extraction and labeling of traffic sessions. A new dataset with botnet network traffic was generated by the framework to assess our proposed method with machine learning algorithms suitable for unbalanced data. The performance of the classifiers was evaluated in terms of macro-averages of F1-score (0.97) and the Matthews Correlation Coefficient (0.94), showing a good overall performance average.


Asunto(s)
Algoritmos , Aprendizaje Automático , Proyectos de Investigación
3.
Sensors (Basel) ; 19(9)2019 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-31064133

RESUMEN

With the rapid deployment of the Internet of Things and cloud computing, it is necessary to enhance authentication protocols to reduce attacks and security vulnerabilities which affect the correct performance of applications. In 2019 a new lightweight IoT-based authentication scheme in cloud computing circumstances was proposed. According to the authors, their protocol is secure and resists very well-known attacks. However, when we evaluated the protocol we found some security vulnerabilities and drawbacks, making the scheme insecure. Therefore, we propose a new version considering login, mutual authentication and key agreement phases to enhance the security. Moreover, we include a sub-phase called evidence of connection attempt which provides proof about the participation of the user and the server. The new scheme achieves the security requirements and resists very well-known attacks, improving previous works. In addition, the performance evaluation demonstrates that the new scheme requires less communication-cost than previous authentication protocols during the registration and login phases.

4.
Sensors (Basel) ; 19(4)2019 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-30769781

RESUMEN

The monitoring and processing of electrocardiogram (ECG) beats have been actively studied in recent years: new lines of research have even been developed to analyze ECG signals using mobile devices. Considering these trends, we proposed a simple and low computing cost algorithm to process and analyze an ECG signal. Our approach is based on the use of linear regression to segment the signal, with the goal of detecting the R point of the ECG wave and later, to separate the signal in periods for detecting P, Q, S, and T peaks. After pre-processing of ECG signal to reduce the noise, the algorithm was able to efficiently detect fiducial points, information that is transcendental for diagnosis of heart conditions using machine learning classifiers. When tested on 260 ECG records, the detection approach performed with a Sensitivity of 97.5% for Q-point and 100% for the rest of ECG peaks. Finally, we validated the robustness of our algorithm by developing an ECG sensor to register and transmit the acquired signals to a mobile device in real time.


Asunto(s)
Electrocardiografía/métodos , Corazón/fisiología , Algoritmos , Corazón/diagnóstico por imagen , Humanos , Modelos Lineales , Procesamiento de Señales Asistido por Computador
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA