Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Circ J ; 87(6): 783-790, 2023 05 25.
Artículo en Inglés | MEDLINE | ID: mdl-36990778

RESUMEN

BACKGROUND: Angiographic fractional flow reserve (angioFFR) is a novel artificial intelligence (AI)-based angiography-derived fractional flow reserve (FFR) application. We investigated the diagnostic accuracy of angioFFR to detect hemodynamically relevant coronary artery disease.Methods and Results: Consecutive patients with 30-90% angiographic stenoses and invasive FFR measurements were included in this prospective, single-center study conducted between November 2018 and February 2020. Diagnostic accuracy was assessed using invasive FFR as the reference standard. In patients undergoing percutaneous coronary intervention, gradients of invasive FFR and angioFFR in the pre-senting segments were compared. We assessed 253 vessels (200 patients). The accuracy of angioFFR was 87.7% (95% confidence interval [CI] 83.1-91.5%), with a sensitivity of 76.8% (95% CI 67.1-84.9%), specificity of 94.3% (95% CI 89.5-97.4%), and area under the curve of 0.90 (95% CI 0.86-0.93%). AngioFFR was well correlated with invasive FFR (r=0.76; 95% CI 0.71-0.81; P<0.001). The agreement was 0.003 (limits of agreement: -0.13, 0.14). The FFR gradients of angioFFR and invasive FFR were comparable (n=51; mean [±SD] 0.22±0.10 vs. 0.22±0.11, respectively; P=0.87). CONCLUSIONS: AI-based angioFFR showed good diagnostic accuracy for detecting hemodynamically relevant stenosis using invasive FFR as the reference standard. The gradients of invasive FFR and angioFFR in the pre-stenting segments were comparable.


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Humanos , Estudios Prospectivos , Estenosis Coronaria/diagnóstico por imagen , Inteligencia Artificial , Angiografía Coronaria/métodos , Índice de Severidad de la Enfermedad , Valor Predictivo de las Pruebas
2.
Catheter Cardiovasc Interv ; 99(4): 1047-1058, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35170843

RESUMEN

OBJECTIVE: We investigated the effect of proximal optimization technique (POT) on coronary bifurcation stent failure (BSF) in cross-over stenting by comparing with the kissing balloon technique (KBT) in a multicenter randomized PROPOT trial. BACKGROUND: POT is recommended due to increased certainty for optimal stent expansion and side branch (SB) wiring. METHODS: We randomized 120 patients treated with crossover stenting into the POT group, which was followed by SB dilation (SBD), and the KBT group. Finally, 52 and 57 patients were analyzed by optical coherence tomography before SBD and at the final procedure, respectively. Composite BSF was defined as a maximal malapposition distance of >400 µm, or malapposed and SB-jailed strut rates of >5.95% and >21.4%, respectively. RESULTS: Composite BSF before SBD in the POT and KBT groups was observed in 29% and 26% of patients, respectively. In the POT group, differences in stent volumetric index between the proximal and distal bifurcation (odds ratio [OR] 60.35, 95% confidential interval [CI] 0.13-0.93, p = 0.036) and between the proximal bifurcation and bifurcation core (OR: 3.68, 95% CI: 1.01-13.40, p = 0.048) were identified as independent risk factors. Composite BSF at final in 27% and 32%, and unplanned additional procedures in 38% and 25% were observed, respectively. Composite BSF before SBD was a risk factor for the former (OR: 6.33, 95% CI: 1.10-36.50, p = 0.039) and the latter (OR: 6.43, 95% CI: 1.25-33.10, p = 0.026) in the POT group. CONCLUSION: POT did not result in a favorable trend in BSF. Insufficient expansion of the bifurcation core after POT was associated with BSF.


Asunto(s)
Angioplastia Coronaria con Balón , Enfermedad de la Arteria Coronaria , Insuficiencia Cardíaca , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/métodos , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/etiología , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Insuficiencia Cardíaca/etiología , Humanos , Stents , Tomografía de Coherencia Óptica , Resultado del Tratamiento
3.
Heart Vessels ; 37(10): 1689-1700, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35524780

RESUMEN

The purpose of the present study was to develop a 60 MHz integrated backscatter intravascular ultrasound (IB-IVUS) and to evaluate its usefulness for the detection of lipid area with backward attenuation of ultrasound signal (AT) that for the prediction of post-procedural myocardial injury (PMI) after percutaneous coronary intervention (PCI). In a pathological study, images were acquired from 221 cross-sections of 18 coronary arteries from 13 cadavers obtained at autopsy. In the clinical training study, we compared non-targeted plaques in 38 patients by a previous IB-IVUS system (38 MHz) and a new IB-IVUS system (60 MHz). In the clinical testing study, we included 70 consecutive patients who underwent PCI. Serum troponin-I was measured just before and 24 h after PCI to evaluate PMI. As the % microcalcification + % cholesterol cleft area increased, the attenuation of IB values increased (r = 0.56, p < 0.001). The slopes of regression lines of the area of each tissue component between 38 and 60 MHz IB-IVUS were excellent. The lipid pool area with AT tended to be more useful than that of the conventional lipid pool area for the prediction of PMI (p = 0.11). We developed a 60 MHz IB-IVUS imaging system for tissue characterization of coronary plaques. Cutoff value of purple color was the most reliable value for the prediction of PMI.


Asunto(s)
Enfermedad de la Arteria Coronaria , Lesiones Cardíacas , Intervención Coronaria Percutánea , Placa Aterosclerótica , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/cirugía , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/patología , Lesiones Cardíacas/diagnóstico por imagen , Lesiones Cardíacas/etiología , Humanos , Lípidos , Intervención Coronaria Percutánea/efectos adversos , Placa Aterosclerótica/diagnóstico , Placa Aterosclerótica/patología , Ultrasonografía Intervencional/métodos
4.
AJR Am J Roentgenol ; 216(6): 1492-1499, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-32876482

RESUMEN

BACKGROUND. For clinical decision making, it was recently recommended that values of fractional flow reserve (FFR) derived from coronary CTA (FFRCT) be measured 1-2 cm distal to the stenosis, given the potential for overestimation of ischemia when FFRCT values at far distal segments are used. Supporting data are, however, lacking. OBJECTIVE. The purpose of the present study was to evaluate the diagnostic performance of FFRCT values measured 1-2 cm distal to the stenosis and at more distal locations relative to invasive FFR values. METHODS. FFRCT and invasive FFR values for 365 vessels in 253 patients identified from the Assessing Diagnostic Value of Noninvasive FFRCT in Coronary Care (ADVANCE) registry were prospectively assessed. FFRCT values were measured 1-2 cm distal to the stenosis and at the pressure wire position and far distal segments. The diagnostic accuracy of FFRCT was assessed on the basis of the ROC AUC. The AUC of FFRCT was calculated using FFRCT as an explanatory variable and an invasive FFR of 0.80 or less as the dichotomous dependent variable. RESULTS. The AUC of FFRCT values measured 1-2 cm distal to the stenosis (0.85; 95% CI, 0.80-0.88) was higher (p = .002) than that of FFRCT values measured at far distal segments (0.80; 95% CI, 0.76-0.84) and similar (p = .16) to that of FFRCT values measured at the pressure wire position (0.86; 95% CI, 0.81-0.89). FFRCT values measured 1-2 cm distal to the stenosis and at far distal segments had sensitivity of 87% versus 92% (p = .003), specificity of 73% versus 42% (p < .001), PPV of 75% versus 59% (p < .001), and NPV of 86% versus 85% (p = .72), respectively. Subgroup analyses of lesions of the left anterior descending coronary artery, left circumflex coronary artery, and right coronary artery all showed improved specificity and PPV (all p < .005) for FFRCT values measured 1-2 cm distal to the stenosis compared with values measured at the pressure wire position. However, the AUC was higher for measurements obtained 1-2 cm distal to the stenosis versus those obtained at far distal segments, for left anterior descending coronary artery lesions (p < .001) but not for left circumflex coronary artery lesions (p = .27) or right coronary artery lesions (p = .91). CONCLUSION. The diagnostic performance of FFRCT values measured 1-2 cm distal to the stenosis was higher than that of FFRCT values measured at far distal segments and was similar to that of FFRCT values measured at the pressure wire position in evaluating ischemic status, particularly for left anterior descending coronary artery lesions. CLINICAL IMPACT. The present study supports recent recommendations from experts to use FFRCT measured 1-2 cm distal to the stenosis, rather than measurements obtained at far distal segments, in clinical decision making.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Estenosis Coronaria/diagnóstico , Estenosis Coronaria/fisiopatología , Reserva del Flujo Fraccional Miocárdico/fisiología , Anciano , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valores de Referencia , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad
5.
Circ J ; 85(11): 2043-2049, 2021 10 25.
Artículo en Inglés | MEDLINE | ID: mdl-34148928

RESUMEN

BACKGROUND: Myocardial perfusion imaging (MPI) and fractional flow reserve (FFR) are established approaches to the assessment of myocardial ischemia. Recently, various FFR cutoff values were proposed, but the diagnostic accuracy of MPI in identifying positive FFR using various cutoff values is not well established.Methods and Results:We retrospectively studied 273 patients who underwent stress MPI and FFR within a 3-month period. Results for FFR were obtained from 218 left anterior descending artery (LAD) lesions and 207 non-LAD lesions. Stress MPI and FFR demonstrated a good correlation in the detection of myocardial ischemia. However, the positive predictive value (PPV) of FFR for detecting MPI-positive lesions at the optimal FFR thresholds was insufficient (44% for LAD and 65% for non-LAD lesions). This was caused by a sharp drop in PPV at an FFR threshold of 0.7 or more. Notably, 41% of the lesions with normal MPI demonstrated FFRs <0.80. However, MPI-negative lesions had an extremely low lesion rate with FFR <0.65 (6%). Conversely, 78% and 41% of MPI-positive lesions had FFR <0.80 and <0.65, respectively. CONCLUSIONS: The data confirmed that decisions based on MPI are reasonable because MPI-negative patients have an extremely low rate of lesions with a FFR below the cutoff point for a hard event, and MPI-positive lesions include many lesions with FFR <0.65.


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Isquemia Miocárdica , Imagen de Perfusión Miocárdica , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Humanos , Imagen de Perfusión Miocárdica/métodos , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Índice de Severidad de la Enfermedad
6.
Catheter Cardiovasc Interv ; 96(4): 773-781, 2020 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-31691499

RESUMEN

OBJECTIVES: We sought to evaluate the efficacy of plaque debulking by directional coronary atherectomy (DCA) prior to second-generation drug-eluting stent (DES) implantation for bifurcated coronary lesions. BACKGROUND: Percutaneous coronary intervention (PCI) for bifurcated lesions still remains complex and challenging in terms of restenosis or stent thrombosis regardless of whether simple or complex stenting is used. METHODS: Patients with bifurcated lesions were enrolled in this prospective multicenter registry. Pre-second-generation DES plaque debulking with a novel DCA catheter (ATHEROCUT®, Nipro Co., Osaka, Japan) was conducted. All patients were scheduled to perform a follow up angiography (9-12 month coronary angiography or coronary computed tomography). The primary end point was target vessel failure (TVF) at follow up. Secondary end points were procedure-related events and major adverse cardiac events at 1 year. RESULTS: A total of 77 patients with bifurcated lesions were enrolled. PCI with DCA was performed successfully in all cases without any major procedure-related event and only one case required complex stenting. The TVF rate at 9-12 month follow up was 3.9% (3 of 77) and those were all associated with revascularization of the target vessel. Restenosis was only observed at the ostium of the main-branch in three cases. No death, coronary artery bypass grafting, or myocardial infarction were reported for any patients within the first year. CONCLUSION: DCA before second-generation DES implantation can possibly avoid complex stenting and provide a good mid-term outcome in patients with bifurcated lesions.


Asunto(s)
Aterectomía Coronaria , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/instrumentación , Placa Aterosclerótica , Anciano , Aterectomía Coronaria/efectos adversos , Angiografía por Tomografía Computarizada , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Femenino , Humanos , Japón , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Sistema de Registros , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía Intervencional
7.
Catheter Cardiovasc Interv ; 94(2): E61-E66, 2019 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-30723996

RESUMEN

OBJECTIVES: The objective was to evaluate the safety, feasibility, and accuracy of the jailed-pressure wire technique using a durable optical fiber-based pressure wire with high-pressure dilatation using a non-compliant balloon after main vessel stenting. BACKGROUND: Fractional flow reserve (FFR) information can help interventionists determine whether they should treat a jailed-side branch (SB). However, re-crossing a pressure wire into a jailed-SB is sometimes technically difficult. METHODS: Fifty-one consecutive lesions from 48 patients who underwent the jailed-pressure wire technique were retrospectively investigated. The primary endpoint was complication rate and secondary endpoints included success rate of FFR measurement, incidence of wire disruption, and final drift rate. The usability of FFR for percutaneous coronary intervention of coronary bifurcation lesion was also evaluated. RESULTS: Median age of the patients was 69 years and 80.4% were men. The most frequent underlying disease was stable angina (70.6%) and 68.6% were type B2 lesions. Our main findings were: the procedure was performed successfully in all cases without any complications or wire disruption, FFR could be measured without significant final drift in 95.9% of cases, and FFR measurements helped interventionists determine whether to perform a final kissing balloon dilatation in 49.0% cases. CONCLUSIONS: The jailed-pressure wire technique using a durable optical fiber-based pressure wire with high-pressure post-dilatation maneuver was safe, feasible, and accurate.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Cateterismo Cardíaco/instrumentación , Catéteres Cardíacos , Enfermedad de la Arteria Coronaria/terapia , Tecnología de Fibra Óptica/instrumentación , Fibras Ópticas , Transductores de Presión , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Cateterismo Cardíaco/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/fisiopatología , Diseño de Equipo , Estudios de Factibilidad , Femenino , Reserva del Flujo Fraccional Miocárdico , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Stents , Resultado del Tratamiento
8.
Circ J ; 82(11): 2837-2844, 2018 10 25.
Artículo en Inglés | MEDLINE | ID: mdl-30175800

RESUMEN

BACKGROUND: This study compared the diagnostic value of myocardial perfusion imaging (MPI) between the rest-stress 99 mTc-tetrofosmin protocol (Tc/Tc protocol) and simultaneous acquisition rest 99 mTc-tetrofosmin/stress 201Tl dual-isotope protocol (SDI protocol) with a semiconductor camera.Methods and Results: We retrospectively studied 147 patients who underwent stress MPI using a cadmium-zinc-telluride camera and invasive coronary angiography within a 3-month interval. The Tc/Tc and SDI protocols were used in 59 and 88 patients, respectively. The sensitivity, specificity, and accuracy of the summed difference score in per-patient analysis were 56%, 85%, and 69%, respectively, for the Tc/Tc protocol and 89%, 82%, and 85%, respectively, for the SDI protocol. The area under the receiver operating characteristic curve was significantly better for the SDI than Tc/Tc protocol for the left anterior descending artery (0.836 vs. 0.674; P=0.0380), the left circumflex artery (0.754 vs. 0.599; P=0.0441), and in per-patient analysis (0.875 vs. 0.707; P=0.0135). There was no significant difference in the diagnostic accuracy of the summed stress score for any vessel or in per-patient analysis between the 2 protocols. CONCLUSIONS: The SDI protocol had a higher diagnostic accuracy for the detection of coronary ischemia than the Tc/Tc protocol.


Asunto(s)
Angiografía Coronaria , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/fisiopatología , Imagen de Perfusión Miocárdica , Compuestos Organofosforados/administración & dosificación , Compuestos de Organotecnecio/administración & dosificación , Radioisótopos de Talio/administración & dosificación , Tomografía Computarizada de Emisión de Fotón Único , Anciano , Anciano de 80 o más Años , Prueba de Esfuerzo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
10.
Int Heart J ; 54(4): 237-9, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23924938

RESUMEN

A 53-year-old male complaining of chest pain was admitted to our hospital with suspected acute myocardial infarction (AMI). Emergent coronary angiography (CAG) determined a totally occluded middle right coronary artery (RCA). Thrombus aspiration was conducted, followed by intravascular ultrasound (IVUS) imaging. Diffuse intima plus media thickness was identified at the obstruction site and a thrombus was observed proximally to the occlusion site on IVUS. Following isosorbide dinitrate (ISDN) administration, dilatation of the RCA was confirmed. IVUS study indicated the luminal dilatation was achieved by the release of the diffuse intima plus media thickening. Of note, plaque volume showed no significant difference after administration of ISDN at any vessel site. These results clearly show that luminal dilatation and vessel dilatation were achieved from the redistribution of plaque volume (intima plus media). A follow-up CAG showed no significant stenosis in the RCA. After a provocation test using methylergometrine maleate, the RCA was totally occluded at the very site of the initial event. The involvement of vasospasm as a cause of AMI in the present case was doubly confirmed with characteristic IVUS images of vasospasm in the acute phase and with a provocation test at follow-up.


Asunto(s)
Vasoespasmo Coronario/complicaciones , Vasos Coronarios/diagnóstico por imagen , Infarto del Miocardio/etiología , Ultrasonografía Intervencional/métodos , Vasoespasmo Coronario/diagnóstico por imagen , Diagnóstico Diferencial , Estudios de Seguimiento , Humanos , Masculino , Infarto del Miocardio/diagnóstico por imagen
11.
Int Heart J ; 54(6): 341-7, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24309442

RESUMEN

The timing and incidence of neointimal calcification after stenting (NIC) is largely unknown. The purpose of our study was to elucidate the characteristics of NIC. The presence of NIC in patients who underwent intravascular ultrasound between June 30, 2009 and June 30, 2012 was analyzed. The patients were divided into two groups based on the follow-up period: < 365 days or ≥ 365 days. A total of 181 images were analyzed. Those with NIC had a lower estimated glomerular filtration rate [51 (6-60) versus 61 (52-72) mL/minute/1.73 m²; P < 0.01] and longer time after stenting [3198 (1710-3684) versus 211 (180-516) days; P < 0.01] compared to those without NIC. NIC during short-term follow-up was observed only in patients who were on hemodialysis. On the other hand, NIC in the long-term follow-up was observed only in patients with bare metal stents. The development of NIC was related to renal function and time after stenting. NIC in the short-term and the long-term follow-up was observed only in patients who were on hemodialysis and who were implanted with a bare metal stent, respectively.


Asunto(s)
Calcinosis/diagnóstico por imagen , Reestenosis Coronaria/diagnóstico por imagen , Neointima/diagnóstico por imagen , Intervención Coronaria Percutánea , Insuficiencia Renal Crónica/complicaciones , Stents/efectos adversos , Anciano , Calcinosis/etiología , Reestenosis Coronaria/etiología , Reestenosis Coronaria/terapia , Estenosis Coronaria/complicaciones , Estenosis Coronaria/terapia , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Neointima/patología , Intervención Coronaria Percutánea/efectos adversos , Diálisis Renal , Insuficiencia Renal Crónica/terapia , Reoperación , Estudios Retrospectivos , Ultrasonografía Intervencional
12.
Front Cardiovasc Med ; 10: 1127121, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37077746

RESUMEN

Background: This study compares the efficacy of coronary computed tomography angiography (CCTA) and near-infrared spectroscopy intravascular ultrasound (NIRS-IVUS) in patients with significant coronary stenosis for predicting periprocedural myocardial injury during percutaneous coronary intervention (PCI). Methods: We prospectively enrolled 107 patients who underwent CCTA before PCI and performed NIRS-IVUS during PCI. Based on the maximal lipid core burden index for any 4-mm longitudinal segments (maxLCBI4mm) in the culprit lesion, we divided the patients into two groups: lipid-rich plaque (LRP) group (maxLCBI4mm ≥ 400; n = 48) and no-LRP group (maxLCBI4mm < 400; n = 59). Periprocedural myocardial injury was a postprocedural cardiac troponin T (cTnT) elevation of ≥5 times the upper limit of normal. Results: The LRP group had a significantly higher cTnT (p = 0.026), lower CT density (p < 0.001), larger percentage atheroma volume (PAV) by NIRS-IVUS (p = 0.036), and larger remodeling index measured by both CCTA (p = 0.020) and NIRS-IVUS (p < 0.001). A significant negative linear correlation was found between maxLCBI4mm and CT density (rho = -0.552, p < 0.001). Multivariable logistic regression analysis identified maxLCBI4mm [odds ratio (OR): 1.006, p = 0.003] and PAV (OR: 1.125, p = 0.014) as independent predictors of periprocedural myocardial injury, while CT density was not an independent predictor (OR: 0.991, p = 0.22). Conclusion: CCTA and NIRS-IVUS correlated well to identify LRP in culprit lesions. However, NIRS-IVUS was more competent in predicting the risk of periprocedural myocardial injury.

13.
Int J Cardiol Heart Vasc ; 48: 101265, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37680550

RESUMEN

Background: The impact of coronary bifurcation angle (BA) on incomplete stent apposition (ISA) after crossover stenting followed by side branch (SB) intervention has not been established. Methods: A total of 100 crossover stentings randomly treated with proximal optimization technique followed by short balloon dilation in the SB (POT-SBD group, 48 patients) and final kissing balloon technique (KBT group, 52 patients) were analyzed in the PROPOT trial. Major ISA with maximum distance > 400 µm and its location was determined using optical coherence tomography before SB intervention and at the final procedure. The BA was defined as the angle between the distal main vessel and SB. Optimal POT was determined when the difference in stent volume index between the proximal and distal bifurcation was greater than the median value (0.86 mm3/mm) before SB intervention. Result: Major ISA was more frequently observed in the POT-SBD than in the KBT group (35% versus 17%, p < 0.05). In the POT-SBD group, worsening ISA after SBD was prominent at the distal bifurcation. The BA was an independent predictor of major ISA (odds ratio 1.04, 95% confidence interval 1.00-1.07, p < 0.05) with a cut-off value of 59.5° (p < 0.05). However, the cases treated with optimal POT in the short BA (<60°) indicated the lowest incidence of major ISA. In the KBT group, BA had no significant impact. Conclusion: A wide BA has a potential risk for the occurrence of major ISA after POT followed by SBD in coronary bifurcation stenting.

14.
Cardiovasc Ultrasound ; 10: 28, 2012 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-22747941

RESUMEN

BACKGROUND: It is recognized that one of the causes of atrial fibrillation (AF) is pathological degeneration of the left atrium (LA). However, prospective study that elucidated the relationship between the incidence of persistent AF and pathological degeneration has not been performed. The purpose of this study was to elucidate the usefulness of integrated backscatter (IBS) values for the prediction of progression from paroxysmal AF (PAF) to persistent AF. METHODS: We measured IBS values of the entire LA wall at 5 mm intervals (except the posterior wall) in 27 patients with paroxysmal AF and evaluated progression to persistent AF for three years. IBS values were acquired with transesophageal echocardiography (TEE) using a 4-7 MHz transducer. IBS values were calculated as the average power of the backscattered signal from regions of interest (ROI). Each IBS value was color-coded to construct three dimensional maps. RESULTS: Average IBS values of total voxels in color-coded maps in the persistent AF group were significantly greater than those in the non-persistent AF group (25.8 ± 5.0 dB vs. 17.4 ± 10.2 dB, p = 0.047), whereas there was no significant difference in LA diameter between the persistent AF and the non-persistent AF group. There was significant difference in persistent AF-free survival after the baseline measurements in the subjects stratified by IBS value (< 20 dB versus ≥ 20 dB) (univariate Cox regression analysis: hazard ratio: 8.74, p =0.046). CONCLUSION: Using IBS values measured by TEE, we can identify an increase in atrial degeneration that may predict the occurrence of persistent AF before LA dilation.


Asunto(s)
Fibrilación Atrial/diagnóstico por imagen , Ecocardiografía Transesofágica/métodos , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/patología , Interpretación de Imagen Asistida por Computador/métodos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
15.
Cardiovasc Ultrasound ; 10: 33, 2012 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-22867277

RESUMEN

BACKGROUND: The purpose of this study was to determine the cut-off values of Hounsfield units (HU) for the discrimination of plaque components and to evaluate the feasibility of measurement of the volume of plaque components using multi-detector row computed tomography (MDCT). METHODS: Coronary lesions (125 lesions in 125 patients) were visualized by both integrated backscatter intravascular ultrasound (IB-IVUS) and 64-slice MDCT at the same site. The IB values were used as a gold standard to determine the cut off values of HU for the discrimination of plaque components. RESULTS: Plaques were classified as lipid pool (n =50), fibrosis (n =65) or calcification (n =35) by IB-IVUS. The HU of lipid pool, fibrosis and calcification were 18 ± 18 HU (-19 to 58 HU), 95 ± 24 HU (46 to 154 HU) and 378 ± 99 HU (188 to 605 HU), respectively. Using receiver operating characteristic curve analysis, a threshold of 50 HU was the optimal cutoff values to discriminate lipid pool from fibrosis. Lipid volume measured by MDCT was correlated with that measured by IB-IVUS (r =0.66, p <0.001), whereas fibrous volume was not (r =0.21, p =0.059). CONCLUSION: Lipid volume measured by MDCT was moderately correlated with that measured by IB-IVUS. MDCT may be useful for volumetric assessment of the lipid volume of coronary plaques, whereas the assessment of fibrosis volume was unstable.


Asunto(s)
Estenosis Coronaria/diagnóstico , Vasos Coronarios/diagnóstico por imagen , Tomografía Computarizada Multidetector/métodos , Placa Aterosclerótica/diagnóstico , Ultrasonografía Intervencional/métodos , Anciano , Femenino , Estudios de Seguimiento , Humanos , Masculino , Placa Aterosclerótica/complicaciones , Curva ROC , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad
16.
Cardiovasc Ultrasound ; 10: 32, 2012 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-22846428

RESUMEN

BACKGROUND: The purpose of the present study was to evaluate the mechanical properties of coronary plaques and plaque behavior, and to elucidate the relationship among tissue characteristics of coronary plaques, mechanical properties and coronary risk factors using integrated backscatter intravascular ultrasound (IB-IVUS). METHODS: Non-targeted plaques with moderate stenosis (plaque burden at the minimal lumen site: 50-70%) located proximal to the site of the percutaneous coronary intervention target lesions were evaluated by IB-IVUS. Thirty-six plaques (less calcified group: an arc of calcification ≤10°) in 36 patients and 22 plaques (moderately calcified group: 10° < an arc of calcification ≤60°) in 22 patients were evaluated. External elastic membrane volume (EEMV) compliance, lumen volume (LV) compliance, plaque volume (PV) response (difference between PV in systole and diastole), EEM area stiffness index were measured at the minimal lumen site. Relative lipid volume (lipid volume/internal elastic membrane volume) was calculated by IB-IVUS. RESULTS: In the less calcified group, there was a significant correlation between EEMV compliance and the relative lipid volume (r = 0.456, p = 0.005). There was a significant inverse correlation between EEM area stiffness index and the relative lipid volume (p = 0.032, r = -0.358). The LV compliance and EEM area stiffness index were significantly different in the diabetes mellitus (DM) group than in the non-DM group (1.32 ± 1.49 vs. 2.47 ± 1.79%/10 mmHg, p =0.014 and 28.3 ± 26.0 vs. 15.7 ± 17.2, p =0.020). The EEMV compliance and EEM area stiffness index were significantly different in the hypertension (HTN) group than in the non-HTN group (0.77 ± 0.68 vs. 1.57 ± 0.95%/10 mmHg, p =0.012 and 26.5 ± 24.3 vs. 13.0 ± 16.7, p =0.020). These relationships were not seen in the moderately calcified group. CONCLUSION: The present study provided new findings that there was a significant correlation between mechanical properties and tissue characteristics of coronary arteries. In addition, our results suggested that the EEMV compliance and the LV compliance were independent and the compliance was significantly impaired in the patients with DM and/or HTN. Assessment of coronary mechanical properties during PCI may provide us with useful information regarding the risk stratification of patients with coronary heart disease.


Asunto(s)
Estenosis Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Imagenología Tridimensional , Placa Aterosclerótica/diagnóstico por imagen , Anciano , Estenosis Coronaria/etiología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Placa Aterosclerótica/complicaciones , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad , Ultrasonografía Intervencional
17.
Eur Heart J Open ; 2(1): oeac005, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35919655

RESUMEN

Aims: The incidence and temporal change in coronary evagination (CE) after first-generation drug-eluting stent implantation is well established, whereas that after biodegradable polymer sirolimus-eluting stent (BP-SES) implantation has not yet been evaluated. The aim of this study is to assess the incidence and natural history of CE after BP-SES implantation. Methods and results: In this multicenter registry, stable coronary lesions treated by Ultimaster BP-SES were evaluated by serial optical frequency domain imaging (OFDI) (at 0-1-12 or 0-3-12 months) and the incidence of CE was assessed. Coronary evagination was defined as the presence of an outward bulge in luminal vessel contour between apposed struts according to the following criteria: (i) evagination depth ≥10% of nominal stent diameter and (ii) evagination length ≥3.0 mm. Optical frequency domain imaging was obtained in 98, 47, 49, and 87 lesions at 0, 1, 3, and 12 months, respectively. Coronary evagination was observed in 20 (42.6%) and 12 (24.5%) lesions at 1 and 3 months, respectively, and all but one CE had resolved at 12 months. At 12 months, the mean CE area was almost zero and the mean malapposed stent area was also decreased. Comparison of the serial OFDI images indicated that CEs originated mostly from acute stent malapposition or coronary dissection behind the implanted stent. Conclusions: In stable lesions, CE was occasionally observed with Ultimaster BP-SES at 1-3 months but mostly resolved within 12 months, without late-acquired stent malapposition. These findings suggest the safety and feasibility of biodegradable polymer coating on DES.

18.
Cardiovasc Interv Ther ; 37(2): 281-292, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33895962

RESUMEN

The purpose of this study was to assess early and late vascular healing in response to bioresorbable-polymer sirolimus-eluting stents (BP-SESs) for the treatment of patients with ST-elevation myocardial infarction (STEMI) and stable coronary artery disease (CAD). A total of 106 patients with STEMI and 101 patients with stable-CAD were enrolled. Optical frequency-domain images were acquired at baseline, at 1- or 3-month follow-up, and at 12-month follow-up. In the STEMI and CAD cohorts, the percentage of uncovered struts (%US) was significantly and remarkably decreased during early two points and at 12-month (the STEMI cohort: 1-month: 18.75 ± 0.78%, 3-month: 10.19 ± 0.77%, 12-month: 1.80 ± 0.72%; p < 0.001, the CAD cohort: 1-month: 9.44 ± 0.78%, 3-month: 7.78 ± 0.78%, 12-month: 1.07 ± 0.73%; p < 0.001 respectively). The average peri-strut low-intensity area (PLIA) score in the STEMI cohort was significantly decreased during follow-up period (1.90 ± 1.14, 1.18 ± 1.25, and 1.01 ± 0.72; p ≤ 0.001), whereas the one in the CAD cohort was not significantly changed (0.89 ± 1.24, 0.67 ± 1.07, and 0.64 ± 0.72; p = 0.59). In comparison with both groups, differences of %US and PLIA score at early two points were almost disappeared or close at 12 months. The strut-coverage and healing processes in the early phase after BP-SES implantation were significantly improved in both cohorts, especially markedly in STEMI patients. At 1 year, qualitatively and quantitatively consistent neointimal coverage was achieved in both pathogenetic groups.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Infarto del Miocardio , Intervención Coronaria Percutánea , Implantes Absorbibles , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/cirugía , Humanos , Infarto del Miocardio/etiología , Infarto del Miocardio/cirugía , Intervención Coronaria Percutánea/métodos , Polímeros , Sirolimus/efectos adversos , Stents , Tomografía de Coherencia Óptica/métodos , Resultado del Tratamiento
19.
Int J Cardiol Heart Vasc ; 36: 100873, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34568542

RESUMEN

OBJECTIVES: The aim of this study was to identify the predictive factors for suboptimal result in side branch (SB) in chronic total occlusion (CTO) bifurcation lesions and clinical outcomes of patients with suboptimal result in SB. BACKGROUND: There is little evidence on the optimal strategy for bifurcation lesions in CTO. METHODS: We retrospectively reviewed 314 consecutive bifurcation lesions in CTO with SB ≥ 2.5 mm in 3 hospitals from March 2010 to June 2018. Patients were divided into the two groups based on the suboptimal SB treatment (SST) and optimal SB treatment (OST) groups. The baseline characteristics, procedural and clinical outcomes were compared between the two groups. This study also evaluated the predictors of suboptimal result in SB. RESULTS: Suboptimal result in SB occurred in 47 cases. Presence of stenosis in SB, bifurcations located within the occluded segment and sub-intimal tracking at SB ostium was an independent predictor of suboptimal result in SB. The cumulative incidence of target lesion revascularization (TLR) in all lesions was not significantly different between the two groups, however, TLR in right coronary artery (RCA) was significantly higher in the SST group. In the Cox regression analysis, suboptimal result in SB in RCA and sub-intimal tracking were independent predictors of TLR for MB. In patients with bifurcations located within the occluded segment, usage of two-stent technique was significantly lower in the SST group. CONCLUSIONS: Meticulous procedures are required for SB preservation to improve not only SB prognosis but also MB, especially in RCA.

20.
Circ Cardiovasc Interv ; 14(2): e009840, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33541105

RESUMEN

BACKGROUND: Ultrasonic flow ratio (UFR) is a novel method for fast computation of fractional flow reserve (FFR) from intravascular ultrasound images. The objective of this study is to evaluate the diagnostic performance of UFR using wire-based FFR as the reference. METHODS: Post hoc computation of UFR was performed in consecutive patients with both intravascular ultrasound and FFR measurement in a core lab while the analysts were blinded to FFR. RESULTS: A total of 167 paired comparisons between UFR and FFR from 94 patients were obtained. Median FFR was 0.80 (interquartile range, 0.68-0.89) and 50.3% had a FFR≤0.80. Median UFR was 0.81 (interquartile range, 0.69-0.91), and UFR showed strong correlation with FFR (r=0.87; P<0.001). The area under the curve was higher for UFR than intravascular ultrasound-derived minimal lumen area (0.97 versus 0.89, P<0.001). The diagnostic accuracy, sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, and negative likelihood ratio for UFR to identify FFR≤0.80 was 92% (95% CI, 87-96), 91% (95% CI, 82-96), 96% (95% CI, 90-99), 96% (95% CI, 89-99), 91% (95% CI, 93-96), 25.0 (95% CI, 8.2-76.2), and 0.10 (95% CI, 0.05-0.20), respectively. The agreement between UFR and FFR was independent of lesion locations (P=0.48), prior myocardial infarction (P=0.29), and imaging catheters (P=0.22). Intraobserver and interobserver variability of UFR analysis was 0.00±0.03 and 0.01±0.03, respectively. Median UFR analysis time was 102 (interquartile range, 87-122) seconds. CONCLUSIONS: UFR had a strong correlation and good agreement with FFR. The fast computational time and excellent analysis reproducibility of UFR bears the potential of a wider adoption of integration of coronary imaging and physiology in the catheterization laboratory.


Asunto(s)
Estenosis Coronaria , Angiografía Coronaria , Estenosis Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Reserva del Flujo Fraccional Miocárdico , Hemodinámica , Humanos , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad , Ultrasonografía Intervencional
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA