Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Ultrasound Obstet Gynecol ; 48(2): 193-9, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26663469

RESUMEN

OBJECTIVES: Twin-twin transfusion syndrome (TTTS) complicates 10-15% of monochorionic diamniotic (MCDA) twin pregnancies. The donor response to hypovolemia allows the transfer of vasoactive mediators to the recipient, causing increased recipient afterload and hypertension. Our objective was to apply a novel speckle-tracking technique to measure the aortic fractional area change (AFAC) during the cardiac cycle in MCDA twins with and without TTTS, and identify intertwin differences in AFAC and parameters of cardiac function. METHODS: High-frame rate four-chamber views of the fetal heart, including the mid-thoracic aorta, were collected prospectively in MCDA twin pairs referred to our center between June 2014 and April 2015. Using speckle-tracking software, the endovascular border of the aorta was traced manually during systole, with guidance on cardiac cycle timing by anatomical M-mode. AFAC, defined as the difference between maximum and minimum area divided by minimum area, expressed as a percentage, was calculated offline and averaged over three cardiac cycles. Tissue Doppler and displacement were used to measure long-axis cardiac function. Intra- and interclass correlation coefficients were used to test observer variability. RESULTS: Fifty-one MCDA twin pregnancies were included, comprising uncomplicated MCDA (n = 14), TTTS Stages 1/2 (n = 21) and TTTS Stages 3/4 (n = 16). Median gestational age was 20.4 (range, 16.2-27.5) weeks. Mean ± SD heart rate was 142.6 ± 7.2 bpm with no significant intertwin pair differences. AFAC was significantly higher in recipients than in donors of TTTS pairs (Stages 1/2: 72.3 ± 29.9% vs 43.7 ± 19.3%, P < 0.001; Stages 3/4: 75.2 ± 29.2% vs 42.5 ± 18.4%, P = 0.002), consistent with higher recipient pulse pressure. No intertwin differences in AFAC were seen in uncomplicated MCDA pairs. Inter- and intraclass correlation coefficients for AFAC were 0.894 and 0.888. AFAC correlated significantly with combined cardiac output (r = 0.252, P = 0.011) and left and right E/E' ratio (left: r = 0.302, P = 0.004; right: r = 0.247, P = 0.030). CONCLUSION: AFAC is a quantifiable and reproducible method to assess aortic distensibility and is a promising tool to monitor the response to prelaser therapeutic interventions in pregnancies with TTTS. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.


Asunto(s)
Aorta/fisiopatología , Ecocardiografía Doppler/métodos , Transfusión Feto-Fetal/diagnóstico por imagen , Ultrasonografía Prenatal/métodos , Adolescente , Adulto , Aorta/diagnóstico por imagen , Aorta/embriología , Estudios de Casos y Controles , Femenino , Corazón Fetal/fisiopatología , Transfusión Feto-Fetal/fisiopatología , Edad Gestacional , Humanos , Embarazo , Embarazo Gemelar , Estudios Prospectivos , Reproducibilidad de los Resultados , Gemelos Monocigóticos , Adulto Joven
2.
Ultrasound Obstet Gynecol ; 48(6): 744-751, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26989864

RESUMEN

OBJECTIVES: To evaluate changes in ductus venosus (DV) waveforms and the timing of these changes in twin-twin transfusion syndrome (TTTS), to relate these to disease severity and to assess the clinical applicability of the suggested measurements in the prediction of TTTS. METHODS: DV time intervals and velocity-time integrals (VTI) normalized to cardiac cycle and total VTI, respectively, as well as velocity ratios were analyzed in 149 monochorionic diamniotic (MCDA) twin pairs. Pregnancies were assigned to the following groups: uncomplicated MCDA (n = 29); TTTS Stages I+II (n = 50); TTTS Stages III+IV (n = 49); and pre-TTTS (n = 21), of which 14 remained stable and seven progressed to TTTS. Intertwin differences were calculated as larger/recipient minus smaller/donor and related to disease severity. Receiver-operating characteristics curve analysis was used to distinguish TTTS vs uncomplicated MCDA and pre-TTTS progressing to TTTS vs non-progressing pre-TTTS. Intra- and interobserver reliability of measurement of DV parameters were evaluated using intraclass correlation coefficients (ICCs). RESULTS: No intertwin differences in DV parameters were found in uncomplicated MCDA pregnancies. Diastolic VTIs and filling times were significantly shorter in recipient twins in TTTS cases and in larger pre-TTTS twins in comparison with their cotwins. Time intervals, VTIs and velocity ratios correlated significantly with Quintero stages. An intertwin difference in early filling time (eT) normalized to cardiac cycle, eT (%) ≤ -3.6%, could differentiate TTTS from uncomplicated MCDA pregnancies (82.8% sensitivity; 79.8% specificity) and eT (%) ≤ -2.8% predicted progression to TTTS (73.1% sensitivity; 67.4% specificity). CONCLUSIONS: DV flow profiles and timing of waveform events are already altered in pre-TTTS and early-stage disease, reflecting abnormal ventricular filling and circulatory imbalance. Intertwin comparison of filling times and VTI may allow prediction of evolving TTTS in MCDA pregnancies. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.


Asunto(s)
Transfusión Feto-Fetal/diagnóstico por imagen , Vena Porta/fisiopatología , Ultrasonografía Prenatal/métodos , Femenino , Transfusión Feto-Fetal/fisiopatología , Edad Gestacional , Humanos , Variaciones Dependientes del Observador , Embarazo , Curva ROC , Reproducibilidad de los Resultados , Gemelos Monocigóticos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA