Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
Más filtros

Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Graefes Arch Clin Exp Ophthalmol ; 254(1): 169-75, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26174969

RESUMEN

PURPOSE: The purpose of this study was to evaluate intra-session repeatability of measurements of the iridocorneal angle at different meridians in the nasal and temporal areas in healthy eyes using the Sirius Scheimpflug photography-based system in glaucoma analysis mode. METHODS: A total of 43 eyes of 43 patients ranging in age from 36 to 79 years were enrolled in the study. All eyes received a comprehensive ophthalmologic examination including a complete anterior segment analysis with the Costruzione Strumenti Oftalmici [CSO] Sirius system. Three consecutive measurements of nasal and temporal angles at 0°, ±10°, ±20°, and ±30° meridians were obtained in order to assess the intra-session repeatability of iridocorneal angle measurements provided by the device using the glaucoma analysis mode. Within-subject standard deviation (Sw), coefficient of variation (CV), and intraclass correlation coefficient (ICC) values were calculated. RESULTS: The mean Sw was 1.07 ± 1.09°, 1.22 ± 1.53°, 0.66 ± 0.51°, 0.86 ± 0.57°, 0.68 ± 0.65°, 0.84 ± 0.68°, and 0.91 ± 0.70° at the temporal 30°, 20°, 10°, 0°, -10°, -20°, and -30° positions, respectively. Mean Sw was 3.13 ± 3.15°, 3.43 ± 3.63°, 2.75 ± 2.29°, 2.19 ± 1.55°, 1.90 ± 1.49°, 2.14 ± 1.74°, and 2.24 ± 2.06° at the temporal -30°, -20°, -10°, 0°, 10°, 20°, and 30° positions, respectively. Mean CV ranged from 1.36 ± 1.05 % (nasal 0° position) to 10.92 ± 13.95 % (nasal -20° position). ICC values ranged from 0.778 to 0.972. CONCLUSIONS: The glaucoma analysis mode of the Sirius system provides consistent measurements of the iridocorneal angle at different meridians in healthy eyes, with slightly less consistency for nasal measurements. It may be considered a clinically useful non-invasive technique for the detection of potentially occludable angles.


Asunto(s)
Córnea/anatomía & histología , Iris/anatomía & histología , Fotograbar/métodos , Adolescente , Adulto , Anciano , Cámara Anterior/anatomía & histología , Topografía de la Córnea/instrumentación , Femenino , Voluntarios Sanos , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados
2.
Graefes Arch Clin Exp Ophthalmol ; 253(12): 2229-37, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26344733

RESUMEN

PURPOSE: We aimed to characterize the distribution of the vector parameters ocular residual astigmatism (ORA) and topography disparity (TD) in a sample of clinical and subclinical keratoconus eyes, and to evaluate their diagnostic value to discriminate between these conditions and healthy corneas. METHODS: This study comprised a total of 43 keratoconic eyes (27 patients, 17-73 years) (keratoconus group), 11 subclinical keratoconus eyes (eight patients, 11-54 years) (subclinical keratoconus group) and 101 healthy eyes (101 patients, 15-64 years) (control group). In all cases, a complete corneal analysis was performed using a Scheimpflug photography-based topography system. Anterior corneal topographic data was imported from it to the iASSORT software (ASSORT Pty. Ltd), which allowed the calculation of ORA and TD. RESULTS: Mean magnitude of the ORA was 3.23 ± 2.38, 1.16 ± 0.50 and 0.79 ± 0.43 D in the keratoconus, subclinical keratoconus and control groups, respectively (p < 0.001). Mean magnitude of the TD was 9.04 ± 8.08, 2.69 ± 2.42 and 0.89 ± 0.50 D in the keratoconus, subclinical keratoconus and control groups, respectively (p < 0.001). Good diagnostic performance of ORA (cutoff point: 1.21 D, sensitivity 83.7 %, specificity 87.1 %) and TD (cutoff point: 1.64 D, sensitivity 93.3 %, specificity 92.1 %) was found for the detection of keratoconus. The diagnostic ability of these parameters for the detection of subclinical keratoconus was more limited (ORA: cutoff 1.17 D, sensitivity 60.0 %, specificity 84.2 %; TD: cutoff 1.29 D, sensitivity 80.0 %, specificity 80.2 %). CONCLUSION: The vector parameters ORA and TD are able to discriminate with good levels of precision between keratoconus and healthy corneas. For the detection of subclinical keratoconus, only TD seems to be valid.


Asunto(s)
Astigmatismo/diagnóstico , Córnea/patología , Topografía de la Córnea , Queratocono/diagnóstico , Adolescente , Adulto , Anciano , Astigmatismo/fisiopatología , Biometría , Niño , Humanos , Queratocono/fisiopatología , Persona de Mediana Edad , Estudios Retrospectivos , Adulto Joven
3.
Graefes Arch Clin Exp Ophthalmol ; 253(4): 645-53, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25418035

RESUMEN

PURPOSE: To explore the distribution of total, corneal, and internal higher-order aberrations (HOAs) in both insulin-dependent (IDDM) and non-insulin-dependent (NIDDM) diabetic patients. METHODS: Pilot study including seven patients with IDDM (14 eyes) and 11 patients with NIDDM (22 eyes). Ocular HOAs were examined using ray tracing aberrometry (i-Trace, Tracey Technologies Corp., Houston, TX) and the measurements of anterior segment using Scheimpflug imaging (Pentacam, Oculus Inc. Germany). RESULTS: Total HOAs was slightly higher in IDDM (0.634 ± 0.228 µm, 95% IC ± 0.131) than in NIDDM patients (0.527 ± 0.245 µm, 95% IC ± 0.108) (p = 0.267). The greatest contributor for total ocular HOAs was internal vertical coma (Z3 (- 1)) for both diabetic groups. In NIDDM, age and central corneal thickness (CCT) were correlated with total HOAs (p < 0.001, p = 0.0180 respectively); however, anterior chamber volume (ACV) was inversely correlated with total HOAs (p = 0.019). In IDDM, total HOAs were correlated with posterior asphericity (Q) (p = 0.002) and inversely correlated with ageing (p = 0.013). CONCLUSIONS: Diabetic patients showed high values of total and internal vertical coma (Z3 (- 1)). There might be a role for optical quality measurements in monitoring changes due to DM.


Asunto(s)
Segmento Anterior del Ojo/patología , Aberración de Frente de Onda Corneal/diagnóstico , Diabetes Mellitus Tipo 1/complicaciones , Diabetes Mellitus Tipo 2/complicaciones , Aberrometría , Adulto , Anciano , Topografía de la Córnea , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Refracción Ocular/fisiología
4.
Ophthalmic Physiol Opt ; 35(3): 293-8, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25545996

RESUMEN

PURPOSE: To evaluate the differences in endothelial cell density (ECD) and central corneal thickness (CCT) between type II diabetic patients and age-matched healthy controls, and determine the impact of time from diagnosis. METHODS: This is a comparative study of 77 eyes of type II diabetic patients (33 males, 44 females) and 80 eyes of healthy subjects (42 males, and 38 females) whose ages ranged from 38 to 56 years. CCT, ECD, HbA(1c) levels, and Goldmann tonometry were measured. RESULTS: The CCT was significantly higher and the ECD significantly lower in long-term diabetic patients (10 years + since diagnosis) when compared with short-term diabetic patients (<1 year since diagnosis) and controls (both p < 0.001). No significant differences in CCT (p = 0.30) and ECD (p = 0.31) were found between control groups. Multivariate analysis of variance indicated that there was a significant effect of the diabetes duration in CCT and ECD. In diabetic patients, a two-way analysis of variance showed that CCT was significantly different for a 7.5% HbA(1c) cut-off value, and ECD for both 7.0% and 7.5% HbA(1c) cut-off values. CONCLUSION: Type II diabetes causes a significant alteration in corneal structure and function in the long term. Our study seems to confirm the effect of diabetes duration and poor glycaemic control on CCT and ECD changes.


Asunto(s)
Córnea/patología , Diabetes Mellitus Tipo 2/patología , Adulto , Recuento de Células , Paquimetría Corneal/métodos , Diabetes Mellitus Tipo 2/sangre , Progresión de la Enfermedad , Endotelio Corneal/patología , Femenino , Hemoglobina Glucada/metabolismo , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Tiempo
5.
Eye Contact Lens ; 40(3): e16-20, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24045833

RESUMEN

PURPOSE: To report a very successful outcome obtained with the fitting of a new-generation hybrid contact lens of reverse geometry in a thin cornea with extreme irregularity due to the presence of a central island after unsuccessful myopic excimer laser refractive surgery. METHODS: A 32-year-old man attended to our clinic complaining of very poor vision in his right eye after bilateral laser in situ keratomileusis (treatment or surgery) for myopia correction and some additional retreatments afterward. After a comprehensive ocular evaluation, contact lens fitting with a reverse geometry hybrid contact lens (SynergEyes PS, SynergEyes, Carlsbad, CA) was proposed as a solution for this case. Visual, refractive, and ocular aberrometric outcomes with the contact lens were evaluated. RESULTS: Distance visual acuity improved from a prefitting uncorrected value of 20/200 to a postfitting corrected value of 20/16. Prefitting manifest refraction was +6.00 sphere and -3.00 cylinder at 70°, with a corrected distance visual acuity of 20/40. Higher order root mean square for a 5-mm pupil changed from a prefitting value of 1.45 to 0.34 µm with the contact lens. The contact lens wearing was reported as comfortable, and the patient was very satisfied with this solution. CONCLUSIONS: The SynergEyes PS contact lens seems to be an excellent option for the visual rehabilitation of corneas with extreme irregularity after myopic excimer laser surgery, minimizing the level of higher order aberrations and providing an excellent visual outcome.


Asunto(s)
Lentes de Contacto Hidrofílicos , Enfermedades de la Córnea/terapia , Complicaciones Posoperatorias/terapia , Adulto , Humanos , Masculino , Errores de Refracción/terapia , Resultado del Tratamiento
6.
Graefes Arch Clin Exp Ophthalmol ; 251(1): 331-40, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22562479

RESUMEN

PURPOSE: To evaluate visual, optical, and quality of life (QoL) outcomes and intercorrelations after bilateral implantation of posterior chamber phakic intraocular lenses. METHODS: Twenty eyes with high to moderate myopia of 10 patients that underwent PRL implantation (Phakic Refractive Lens, Carl Zeiss Meditec AG) were examined. Refraction, visual acuity, photopic and low mesopic contrast sensitivity (CS) with and without glare, ocular aberrations, as well as QoL outcomes (National Eye Institute Refractive Error Quality of Life Instrument-42, NEI RQL-42) were evaluated at 12 months postoperatively. RESULTS: Significant improvement in uncorrected (UDVA) and best-corrected distance (CDVA) visual acuities were found postoperatively (p < 0.01), with significant reduction in spherical equivalent (p < 0.01). Low mesopic CS without glare was significantly better than measurements with glare for 1.5, 3, and 6 cycles/degree (p < 0.01). No significant correlations between higher order root mean square (RMS) with CDVA (r = -0.26, p = 0.27) and CS (r ≤ 0.45, p ≥ 0.05) were found. Postoperative binocular photopic CS for 12 cycles/degree and 18 cycles/degree correlated significantly with several RQL-42 scales. Glare index correlated significantly with CS measures and scotopic pupil size (r = -0.551, p = 0.04), but not with higher order RMS (r = -0.02, p = 0.94). Postoperative higher order RMS, postoperative primary coma and postoperative spherical aberration was significant higher for 5-mm pupil diameter (p < 0.01) compared with controls. CONCLUSIONS: Correction of moderate to high myopia by means of PRL implantation had a positive impact on CS and QoL. The aberrometric increase induced by the surgery does not seem to limit CS and QoL. However, perception of glare is still a relevant disturbance in some cases possibly related to the limitation of the optical zone of the PRL.


Asunto(s)
Implantación de Lentes Intraoculares , Miopía/cirugía , Óptica y Fotónica , Lentes Intraoculares Fáquicas , Calidad de Vida , Agudeza Visual/fisiología , Adulto , Sensibilidad de Contraste/fisiología , Femenino , Estudios de Seguimiento , Deslumbramiento , Estado de Salud , Humanos , Masculino , Persona de Mediana Edad , Miopía/fisiopatología , Refracción Ocular/fisiología , Perfil de Impacto de Enfermedad , Resultado del Tratamiento
7.
Graefes Arch Clin Exp Ophthalmol ; 251(3): 977-84, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23052717

RESUMEN

BACKGROUND: To evaluate and report the visual, refractive, and aberrometric outcomes of LASIK for the correction of low to moderate hyperopia in a pilot group using a commercially available solid-state laser METHODS: Prospective pilot study including 11 consecutive eyes with low to moderate hyperopia of six patients undergoing LASIK surgery using the Pulzar Z1 solid-state laser (CustomVis Laser Pty Ltd., currently CV Laser). Visual, refractive, and aberrometric changes were evaluated. Potential complications were evaluated as well. Mean follow-up time was 6.6 months (range, 3 to 11 months). RESULTS: A significant improvement in LogMAR uncorrected distance visual acuity (UDVA) was observed postoperatively (p = 0.01). No significant change was detected in LogMAR corrected distance visual acuity (CDVA) (p = 0.21). Postoperative LogMAR UDVA was 0.1 (about 20/25) or better in ten eyes (90.9 %). Mean overall efficacy and safety indices were 1.03 and 1.12. Postoperatively, no losses of lines of CDVA were observed. Postoperative spherical equivalent was within ± 1.00 D in ten eyes (90.9 %). With regard to aberrations, no statistically significant changes were found in higher order and primary coma RMS postoperatively (p ≥ 0.21), and only minimal but statistically significant negativization of primary spherical aberration (p = 0.02) was observed. No severe complications were observed. CONCLUSION: LASIK surgery using the solid-state laser technology seems to be a useful procedure for the correction of low to moderate hyperopia, with minimal induction of higher order aberrations.


Asunto(s)
Hiperopía/cirugía , Queratomileusis por Láser In Situ , Láseres de Estado Sólido/uso terapéutico , Aberrometría , Adulto , Femenino , Estudios de Seguimiento , Humanos , Hiperopía/fisiopatología , Complicaciones Intraoperatorias , Masculino , Proyectos Piloto , Complicaciones Posoperatorias , Estudios Prospectivos , Refracción Ocular/fisiología , Resultado del Tratamiento , Agudeza Visual/fisiología , Adulto Joven
8.
J Refract Surg ; 28(2): 93-9, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22185467

RESUMEN

PURPOSE: To examine the visual performance of a rotationally asymmetric multifocal intraocular lens (IOL) by correlating the defocus curve of the IOL-implanted eye with the intraocular aberrometric profile and impact on the quality of life. METHODS: A prospective, consecutive, case series study including 26 eyes from 13 patients aged between 50 and 83 years (mean: 65.54±7.59 years) was conducted. All patients underwent bilateral cataract surgery with implantation of a rotationally asymmetric multifocal IOL (Lentis Mplus LS-312 MF30, Oculentis GmbH). Distance and near visual acuity outcomes, intraocular aberrations, defocus curve, and quality of life (assessed using the National Eye Institute Visual Functioning Questionnaire-25) were evaluated postoperatively (mean follow-up: 6.42±2.24 months). RESULTS: A significant improvement in distance visual acuity was found postoperatively (P<.01). Mean postoperative logMAR distance-corrected near visual acuity was 0.19±0.12 (∼20/30). Corrected distance visual acuity and near visual acuity of 20/20 or better were achieved by 30.8% and 7.7% of eyes, respectively. Of all eyes, 96.2% had a postoperative addition between 0 and 1.00 diopter (D). The defocus curve showed two peaks of maximum visual acuity (0 and 3.00 D of defocus), with an acceptable range of intermediate vision. LogMAR visual acuity corresponding to near defocus was directly correlated with some higher order intraocular aberrations (r⩾0.44, P⩽.04). Some difficulties evaluated with the quality of life test correlated directly with near and intermediate visual acuity (r⩾0.50, P⩽.01). CONCLUSIONS: The Lentis Mplus multifocal IOL provides good distance, intermediate, and near visual outcomes; however, the induced intraocular aberrometric profile may limit the potential visual benefit.


Asunto(s)
Aberración de Frente de Onda Corneal/fisiopatología , Implantación de Lentes Intraoculares , Lentes Intraoculares , Seudofaquia/fisiopatología , Calidad de Vida , Refracción Ocular/fisiología , Agudeza Visual/fisiología , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Facoemulsificación , Estudios Prospectivos , Perfil de Impacto de Enfermedad
9.
Optom Vis Sci ; 88(11): E1375-9, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21804437

RESUMEN

PURPOSE: To evaluate the clinical impact and possible causes of a spontaneous decentration of a phakic refractive lens (PRL) implanted in a highly myopic eye, and analyzing the visual, refractive, and aberrometric outcome as well as the possible causes for this phenomenon. METHODS: The description of a case of bilateral high myopia corrected by implantation with the phakic intraocular lens (pIOL) PRL (Carl Zeiss Meditec, Germany) is presented and documented. Both eyes had similar anatomical configuration, and therefore, a pIOL (Model 101) with the same size was implanted without any associated intraoperative complication. Clinical outcomes were evaluated during a 3-month follow-up. RESULTS: Implanted pIOLs were properly positioned in both eyes and provided an excellent visual outcome during the immediate postoperative period. However, 1 month after surgery, the patient presented a logarithm of the minimum angle of resolution uncorrected distance visual acuity of 0.15 and 0 in the OD and OS, respectively. Subjective refraction in the OD was +1.00 to 1.00 × 15°, with logarithm of the minimum angle of resolution corrected distance visual acuity of 0. Temporal displacement of the PRL was evident in the biomicroscopic examination and analyzed in detail with advanced imaging techniques finding an asymmetric vault. Regarding aberrometry, larger amounts of primary coma, and spherical aberration were present in the OS. Two months later, the situation remained stable. CONCLUSIONS: Spontaneous PRL decentration is not necessarily associated with a visual quality loss and a bad selection of pIOL size. For implantation of this pIOL, a comprehensive analysis of the zonule would be necessary.


Asunto(s)
Subluxación del Cristalino/etiología , Miopía/cirugía , Lentes Intraoculares Fáquicas , Complicaciones Posoperatorias , Adulto , Estudios de Seguimiento , Humanos , Subluxación del Cristalino/fisiopatología , Masculino , Miopía/fisiopatología , Refracción Ocular , Agudeza Visual
10.
Int J Ophthalmol ; 12(3): 412-416, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30918809

RESUMEN

AIM: To evaluate the interchangeability of keratometric and asphericity measurements provided by three measurement systems based on different optical principles. METHODS: A total of 40 eyes of 40 patients with a mean age of 34.1y were included. In all cases, a corneal curvature analysis was performed with IOL-Master (IOLM), iDesign 2 (ID2), and Sirius systems (SIR). Differences between instruments for flattest (K1) and steepest (K2) keratometric readings, as well as for magnitude and axis of corneal astigmatism were analyzed. Likewise, differences in asphericity (Q) between SIR and ID2 were also evaluated. RESULTS: Mean differences between devices for K1 were 0.20±0.21 (P<0.001), -0.12±0.36 (P=0.046) and -0.32±0.36 D (P<0.001) for the comparisons IOLM-SIR, IOLM-ID2 and SIR-ID2, respectively. The ranges of agreement for these comparisons between instruments were 0.41, 0.70, and 0.70 D. For K2, mean differences were 0.31±0.33 (P<0.001), -0.08±0.43 (P=0.265) and -0.39±0.38 D (P<0.001), with ranges of agreement of 0.65, 0.84, and 0.74 D. Concerning magnitude of astigmatism, ranges of agreement were in the limit of clinical relevance (0.49 D, P=0.011; 0.55 D, P=0.386; 0.43 D, P=0.05). In contrast, ranges of agreement were clinically relevant for astigmatic axis (26.68°, 33.83° and 18.37°, P≥0.121) and for Q between SIR and ID2 (0.16, P<0.001). CONCLUSION: The keratometric corneal power, astigmatic axis and asphericity measurements provide by the three systems evaluated cannot be considered as interchangeable, whereas measurements of corneal astigmatism obtained with SIR and ID2 can be considered as interchangeable for clinical purposes.

11.
Acta Ophthalmol ; 97(2): e145-e155, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30218490

RESUMEN

To review binocular and accommodative disorders documented after corneal or intraocular refractive surgery, in normal healthy prepresbyopic patients. A bibliographic revision was performed; it included works published before 1st July 2017 where accommodation and/or binocularity was assessed following any type of refractive surgical procedure. The search in Pubmed yielded 1273 papers, 95 of which fulfilled the inclusion criteria. Few publications reporting binocular vision and/or accommodative changes after refractive surgery in normal subjects were found. The reduction in fusional vergence is the most frequently reported alteration. Anisometropia is an important risk factor for postoperative binocular vision-related complaints. Most diplopia-related visual complaints, irrespective of the surgical procedure, were in fact misdiagnosed preoperative disorders. The preoperative evaluation of patients seeking spectacle/contact lens independence should include a complete binocular and accommodation assessment where parameters such as the phoric posture, accommodative amplitude and facility, near point of convergence, fusional reserves and accommodative convergence/accommodation coefficient are measured. This would allow the identification of risk factors that could compromise the success of the refractive surgery and cause clinical symptoms.


Asunto(s)
Extracción de Catarata/efectos adversos , Diplopía/fisiopatología , Complicaciones Posoperatorias , Procedimientos Quirúrgicos Refractivos/efectos adversos , Visión Binocular/fisiología , Acomodación Ocular , Diplopía/etiología , Humanos , Pruebas de Visión
12.
Cornea ; 38(9): 1097-1104, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31246681

RESUMEN

PURPOSE: To evaluate the intrasession repeatability and validity of corneal curvature measurements provided by a new multifunctional device and to assess the intrasession repeatability of its ocular aberrometric measures. METHODS: This prospective study comprises 37 mild to moderate keratoconus eyes of 37 patients. In all cases, 3 repeated measures of corneal topography and ocular aberrometry were performed with the iDesign 2 system (iD2; Johnson & Johnson Vision Care Inc, Jacksonville, FL) and one keratometric measurement was performed with the intraocular lens-(IOL) Master 500 (Carl Zeiss Meditec Inc, Dublin, CA) and Sirius (CSO) (SIR) systems. RESULTS: The within-subject SD (Sw) was <0.50 D for all iD2 keratometric measurements, with intraclass correlation coefficient (ICC) >0.980. Sw and ICC for the keratometric axis were 2.60 degrees and 0.992, respectively. Concerning aberrations, all Sw values for high-order Zernike terms were ≤0.11 µm (ICC > 0.900), and all Sw values for refraction data were <0.75 D (ICC > 0.95), except for J45. No statistically significant differences were found between the devices in any keratometric parameter evaluated (P ≥ 0.222), but the limits of agreement between the devices were clinically relevant. The magnitude of K readings and astigmatism correlated significantly with the difference in these parameters between iD2 and SIR (0.432 ≤ r ≤ 0.489, P ≤ 0.041). CONCLUSIONS: The iD2 system provides consistent measures of keratometry and ocular aberrometry in eyes with mild to moderate keratoconus. Keratometric data obtained with this system in these eyes cannot be considered as interchangeable with data provided by intraocular lens-Master 500 and SIR.


Asunto(s)
Aberrometría , Topografía de la Córnea , Queratocono/diagnóstico , Aberrometría/instrumentación , Aberrometría/normas , Adolescente , Adulto , Anciano , Topografía de la Córnea/instrumentación , Topografía de la Córnea/normas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados , Adulto Joven
13.
Cont Lens Anterior Eye ; 42(1): 75-84, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-29802038

RESUMEN

PURPOSE: To evaluate the differences in corneo-scleral topographic profile between healthy and keratoconus eyes, and their potential diagnostic ability for keratoconus detection. METHODS: Prospective comparative study including 21 keratoconic eyes (11 patients) and 88 healthy eyes (88 patients). In all cases, a complete eye exam was performed including an evaluation of the corneo-scleral profile. The diagnostic ability of corneo-scleral topographic parameters to detect keratoconus was evaluated using the receiver operating characteristic (ROC) curve. RESULTS: A significant lower inferior tangent angle at limbus (ITA) was found in the keratoconic group compared to the control group (p = 0.024). Regarding sagittal heights, significant differences between groups were found in temporal sagittal height (TSH) for 11 mm (p = 0.040), 12 mm (p = 0.041) and 13 mm corneal chords (p = 0.040), difference between temporal and nasal sagittal heights (T-NSH) for 12 mm (p = 0.025) and 13 mm (p = 0.034), and maximum sagittal height (MaxSH) for 12 mm (p = 0.043), with higher values in keratoconus. In bilateral cases, these differences were not found when comparing with the least severe keratoconus eye. Statistical significance for the ROC curve was only found for ITA (p = 0.025), 12-mm (p = 0.048) and 13-mm TSH (p = 0.042), and 13-mm T-NSH (p = 0.037), with cutoff values associated to limited values of sensitivity and specificity. CONCLUSIONS: The corneo-scleral profile in keratoconus presents higher levels of asymmetry compared to healthy eyes, especially in eyes with moderate and advanced stages of the disease. The diagnostic accuracy of corneo-scleral topographic data alone for keratoconus detection is limited and must be used in conjunction with other clinical parameters.


Asunto(s)
Córnea/patología , Topografía de la Córnea , Queratocono/diagnóstico , Esclerótica/patología , Adulto , Anciano , Lentes de Contacto , Femenino , Voluntarios Sanos , Humanos , Queratocono/terapia , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Ajuste de Prótesis , Curva ROC , Sensibilidad y Especificidad , Adulto Joven
14.
Semin Ophthalmol ; 33(5): 620-628, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-28991503

RESUMEN

Microperimetry (MP) is a technology that allows the study of retinal sensitivity at different foveal and parafoveal areas as well as eye fixation. It is a technique of functional evaluation, providing a direct correlation between anatomical and functional outcomes. There are a great variety of studies which evaluate the repeatability or reliability of measurements obtained with this technology and also describe and explore different clinical applications. MP has been shown to be useful in the characterization of sensory and motor conditions, such as amblyopia or nystagmus. Concerning ocular pathology, several studies have confirmed the usefulness of MP for evaluating and analyzing different retinal pathological conditions, such as age-related macular degeneration or glaucoma, and for analyzing the effect of different medical or surgical treatments for these conditions. MP has also been shown to be useful for visual training or rehabilitation in some specific cases.


Asunto(s)
Fijación Ocular/fisiología , Trastornos de la Motilidad Ocular/diagnóstico , Enfermedades de la Retina/diagnóstico , Pruebas del Campo Visual/métodos , Campos Visuales/fisiología , Humanos , Trastornos de la Motilidad Ocular/fisiopatología , Reproducibilidad de los Resultados , Enfermedades de la Retina/fisiopatología
15.
Cont Lens Anterior Eye ; 41(2): 187-192, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29208347

RESUMEN

PURPOSE: To determine the usefulness of a silicone-hydrogel bandage contact lens (BCL) in the immediate postoperative period after uneventful myopic laser in-situ keratomileusis (LASIK). METHODS: The study design was randomized but not masked and data collection was prospective. This study comprised 51 consecutive myopic eyes intervened by means of the LASIK technique to compensate their refractive error. Patients were randomly assigned to two different groups. The experimental group included 24 eyes of 12 patients that were fitted with a BCL immediately after the flap replacement. The control group included 27 eyes of 14 patients with no BCL. Patients were examined 24h after the surgery; the experimental group was analyzed immediately after the extraction of the BCL. Postoperative uncorrected distance visual acuity (UDVA) and postoperative topographic indexes were compared to baseline in both groups. RESULTS: The experimental group achieved worse results in the majority of the studied variables. Postoperative UDVA was worse in experimental group (p<0.01). Likewise, corneal asphericity (Q) was significantly higher in experimental group (p=0.024). Topographic indexes showed higher asymmetry in the corneal maps pertaining to experimental group. Specifically, the index of surface variance (ISV) (p=0.017) and index of vertical asymmetry (IVA) (p=0.031) were higher in experimental group. Also, the postoperative central corneal thickness (CCT) resulted in higher values for eyes pertaining to experimental group. CONCLUSIONS: The fitting of a silicone-hydrogel BCL after uneventful LASIK provokes morphological changes in the ocular structures that may lead to a worse UDVA secondary to a higher postoperative CCT and corneal edema.


Asunto(s)
Vendajes , Lentes de Contacto Hidrofílicos , Queratomileusis por Láser In Situ/métodos , Láseres de Excímeros/uso terapéutico , Miopía/cirugía , Adulto , Córnea/fisiopatología , Topografía de la Córnea , Femenino , Humanos , Masculino , Persona de Mediana Edad , Miopía/fisiopatología , Periodo Posoperatorio , Estudios Prospectivos , Ajuste de Prótesis , Refracción Ocular/fisiología , Agudeza Visual/fisiología , Adulto Joven
17.
Eur J Ophthalmol ; 27(5): 607-613, 2017 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-28127734

RESUMEN

PURPOSE: To establish normative values of retinal sensitivity and parameters describing the fixation pattern using macular analyzer integrity assessment (MAIA) microperimetry (Centervue, Padova, Italy) in adults and children. METHODS: A sample of 237 eyes of 237 healthy subjects aged between 10 and 70 years (mean age 30.63 ± 16.23 years) was evaluated using the MAIA microperimeter. The following parameters provided by the MAIA device were evaluated: average threshold (AT), macular integrity, fixation indexes (P1% and P2%), bivariate contour ellipse area (BCEA) for 95% and 63% of points, and horizontal (H) and vertical (V) axes of the ellipse of fixation. Differences between different age-related groups were evaluated. Correlation of microperimetric parameters with age was also assessed. RESULTS: Median retinal sensitivity of the overall sample was 32.90 dB (interquartile range 1.80 dB). Median P1 and P2 values were 98.00% (6.00) and 100.00% (1.00), respectively. Median BCEA for 95% and 63% of points were 2.40°2 (4.50) and 0.30°2 (0.50), respectively. Median H and V were 0.90° (0.80) and 0.90° (0.70), respectively. Age was significantly correlated with the following parameters in subjects from 21 to 70 years of age (p<0.01): AT (rho -0.47), P1 (rho -0.37), BCEA95 (rho 0.43), BCEA63 (rho 0.42), H (rho 0.43), and V (rho 0.40). CONCLUSIONS: Retinal sensitivity in healthy eyes tends to decrease with age as well as the stability of the pattern of fixation. A normative database in terms of retinal sensitivity threshold and fixation performance can be established in this type of eyes.


Asunto(s)
Fijación Ocular/fisiología , Mácula Lútea/fisiología , Agudeza Visual , Pruebas del Campo Visual/instrumentación , Campos Visuales/fisiología , Adolescente , Adulto , Anciano , Niño , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valores de Referencia , Reproducibilidad de los Resultados , Adulto Joven
18.
Arq Bras Oftalmol ; 80(3): 148-153, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28832737

RESUMEN

PURPOSE: To compare central corneal backscatter obtained from Scheimpflug images between patients with insulin-dependent and non-insulin-dependent diabetes mellitus (IDDM and NIDDM, respectively) and healthy controls. METHODS: Seven patients with IDDM (7 eyes), eleven patients with NIDDM (11 eyes), and sixteen healthy subjects (16 eyes) were included in this pilot study. Scheimpflug imaging system (Pentacam, Oculus Inc., Germany) was used to obtain optical sections of the cornea. Seven meridians were analyzed for each eye, oriented from 70° to 110°. Optical density values for the central 3-mm and 5-mm zones of the cornea were obtained by image analysis using external software. RESULTS: Corneal backscatter was significantly higher in the diabetic patients than in the controls for the central 3-mm (p=0.016) and 5-mm (p=0.014) zones. No significant differences in corneal backscatter were found between the IDDM and NIDDM groups for either zone (both p>0.05). In the NIDDM group, significant correlations were observed for both central zones between corneal backscatter and age (3 mm: r=0.604, p=0.025; 5 mm: r=0.614, p=0.022) and central corneal thickness (3 mm: r=0.641, p=0.017; 5 mm: r=0.671, p=0.012); this was not found in the IDDM group (p>0.05). The presence of diabetes showed a significant effect on central corneal backscatter (Kruskal-Wallis test, p<0.001). CONCLUSIONS: Diabetic patients showed higher values of corneal light backscatter than healthy subjects. Corneal optical density analysis may be a useful tool for monitoring and assessing the ocular changes caused by diabetes.


Asunto(s)
Enfermedades de la Córnea/diagnóstico por imagen , Enfermedades de la Córnea/fisiopatología , Diabetes Mellitus Tipo 1/fisiopatología , Diabetes Mellitus Tipo 2/fisiopatología , Adulto , Factores de Edad , Anciano , Segmento Anterior del Ojo/fisiopatología , Estudios de Casos y Controles , Córnea/fisiopatología , Enfermedades de la Córnea/etiología , Paquimetría Corneal , Diabetes Mellitus Tipo 1/complicaciones , Diabetes Mellitus Tipo 2/complicaciones , Técnicas de Diagnóstico Oftalmológico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Valores de Referencia , Reproducibilidad de los Resultados , Estadísticas no Paramétricas , Agudeza Visual/fisiología
19.
Int J Ophthalmol ; 10(4): 652-655, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28503442

RESUMEN

This study evaluated the clinical outcomes in keratoconus corneas following accelerated transepithelial corneal collagen cross-linking (CXL) (Avedro KXL® system, Waltham, MA, USA) over one year of follow-up. The mean depth of the demarcation line measured by optical coherence tomography (OCT) was 205.19 µm. One month after surgery, a non-statistically significant change was noted in sphere (P=0.18) and in spherical equivalent (P=0.17), whereas a significant improvement was observed in corrected distance visual acuity (P=0.04). A significant change was observed in topographic astigmatism (P=0.03) and posterior corneal a sphericity (P=0.04). Accelerated transepithelial CXL may be a useful technique for the management of progressive keratoconus.

20.
Clin Exp Optom ; 100(2): 107-127, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27800638

RESUMEN

Soft multifocal simultaneous image contact lenses have boomed in recent years due to the growing number of presbyopic patients demanding visual solutions, allowing them to maintain their current standard of living. The concept of 'simultaneous image' is based on blur interpretation and/or blur tolerance of superimposed multiple images on the retina formed by various powers of a contact lens. This is the basis for a specific type of multifocal contact lens developed for the compensation of presbyopia. Manufacturers have released a great variety of soft simultaneous image lens designs to meet different patient needs but their fitting is still unsatisfactory in some cases. Some presbyopes discontinue wearing contact lenses due to some limitations in visual quality and comfort that can be overcome with an appropriate contact lens selection based on a comprehensive pre-fitting evaluation. This paper aims to review the different types of soft multifocal contact lenses that are currently available for presbyopic correction and to define the steps and factors crucial for their fitting, such as pupil, aberrations, accommodation and centring. A discussion about useful tools to achieve a customised fitting leading to a successful outcome, such as the defocus curve, power profile and questionnaires, is performed.


Asunto(s)
Lentes de Contacto Hidrofílicos , Adaptación Fisiológica , Adolescente , Adulto , Anciano , Niño , Preescolar , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Persona de Mediana Edad , Motivación , Satisfacción del Paciente , Selección de Paciente , Presbiopía/terapia , Lágrimas , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA