Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 82
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Anat ; 245(1): 156-180, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38381116

RESUMEN

Extant great apes are characterized by a wide range of locomotor, postural and manipulative behaviours that each require the limbs to be used in different ways. In addition to external bone morphology, comparative investigation of trabecular bone, which (re-)models to reflect loads incurred during life, can provide novel insights into bone functional adaptation. Here, we use canonical holistic morphometric analysis (cHMA) to analyse the trabecular morphology in the distal femoral epiphysis of Homo sapiens (n = 26), Gorilla gorilla (n = 14), Pan troglodytes (n = 15) and Pongo sp. (n = 9). We test two predictions: (1) that differing locomotor behaviours will be reflected in differing trabecular architecture of the distal femur across Homo, Pan, Gorilla and Pongo; (2) that trabecular architecture will significantly differ between male and female Gorilla due to their different levels of arboreality but not between male and female Pan or Homo based on previous studies of locomotor behaviours. Results indicate that trabecular architecture differs among extant great apes based on their locomotor repertoires. The relative bone volume and degree of anisotropy patterns found reflect habitual use of extended knee postures during bipedalism in Homo, and habitual use of flexed knee posture during terrestrial and arboreal locomotion in Pan and Gorilla. Trabecular architecture in Pongo is consistent with a highly mobile knee joint that may vary in posture from extension to full flexion. Within Gorilla, trabecular architecture suggests a different loading of knee in extension/flexion between females and males, but no sex differences were found in Pan or Homo, supporting our predictions. Inter- and intra-specific variation in trabecular architecture of distal femur provides a comparative context to interpret knee postures and, in turn, locomotor behaviours in fossil hominins.


Asunto(s)
Hueso Esponjoso , Fémur , Hominidae , Animales , Masculino , Femenino , Fémur/anatomía & histología , Hominidae/anatomía & histología , Hominidae/fisiología , Humanos , Hueso Esponjoso/anatomía & histología , Locomoción/fisiología , Gorilla gorilla/anatomía & histología , Gorilla gorilla/fisiología , Pan troglodytes/anatomía & histología , Pan troglodytes/fisiología
2.
Proc Natl Acad Sci U S A ; 117(15): 8416-8423, 2020 04 14.
Artículo en Inglés | MEDLINE | ID: mdl-32229560

RESUMEN

Bipedalism is a defining trait of the hominin lineage, associated with a transition from a more arboreal to a more terrestrial environment. While there is debate about when modern human-like bipedalism first appeared in hominins, all known South African hominins show morphological adaptations to bipedalism, suggesting that this was their predominant mode of locomotion. Here we present evidence that hominins preserved in the Sterkfontein Caves practiced two different locomotor repertoires. The trabecular structure of a proximal femur (StW 522) attributed to Australopithecus africanus exhibits a modern human-like bipedal locomotor pattern, while that of a geologically younger specimen (StW 311) attributed to either Homo sp. or Paranthropus robustus exhibits a pattern more similar to nonhuman apes, potentially suggesting regular bouts of both climbing and terrestrial bipedalism. Our results demonstrate distinct morphological differences, linked to behavioral differences between Australopithecus and later hominins in South Africa and contribute to the increasing evidence of locomotor diversity within the hominin clade.


Asunto(s)
Hominidae/fisiología , Animales , Antropología , Evolución Biológica , Fémur/anatomía & histología , Fémur/fisiología , Fósiles/historia , Historia Antigua , Hominidae/anatomía & histología , Humanos , Locomoción , Sudáfrica
3.
Curr Osteoporos Rep ; 18(6): 696-704, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-33068252

RESUMEN

PURPOSE OF REVIEW: Image-based finite element analysis (FEA) to predict and understand the biomechanical response has become an essential methodology in musculoskeletal research. An important part of such simulation models is the constitutive material model of which recent advances are summarized in this review. RECENT FINDINGS: The review shows that existing models from other fields were introduced, such as cohesion zone (cortical bone) or phase-field models (trabecular bone). Some progress has been made in describing cortical bone involving physical mechanisms such as microcracks. Problems with validations at different length scales remain a problem. The improvement of recent constitutive models is partially obscured by uncertainties that affect overall predictions, such as image quality and calibration or boundary conditions. Nevertheless, in vivo CT-based FEA simulations based on a sophisticated constitutive behavior are a very valuable tool for clinical-related osteoporosis research.


Asunto(s)
Remodelación Ósea/fisiología , Osteoporosis/fisiopatología , Animales , Fenómenos Biomecánicos , Análisis de Elementos Finitos , Humanos
4.
J Anat ; 234(5): 679-693, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30793309

RESUMEN

Studies of femoral trabecular structure have shown that the orientation and volume of bone are associated with variation in loading and could be informative about individual joint positioning during locomotion. In this study, we analyse for the first time trabecular bone patterns throughout the femoral head using a whole-epiphysis approach to investigate how potential trabecular variation in humans and great apes relates to differences in locomotor modes. Trabecular architecture was analysed using microCT scans of Pan troglodytes (n = 20), Gorilla gorilla (n = 14), Pongo sp. (n = 5) and Homo sapiens (n = 12) in medtool 4.1. Our results revealed differences in bone volume fraction (BV/TV) distribution patterns, as well as overall trabecular parameters of the femoral head between great apes and humans. Pan and Gorilla showed two regions of high BV/TV in the femoral head, consistent with hip posture and loading during two discrete locomotor modes: knuckle-walking and climbing. Most Pongo specimens also displayed two regions of high BV/TV, but these regions were less discrete and there was more variability across the sample. In contrast, Homo showed only one main region of high BV/TV in the femoral head and had the lowest BV/TV, as well as the most anisotropic trabeculae. The Homo trabecular structure is consistent with stereotypical loading with a more extended hip compared with great apes, which is characteristic of modern human bipedalism. Our results suggest that holistic evaluations of femoral head trabecular architecture can reveal previously undetected patterns linked to locomotor behaviour in extant apes and can provide further insight into hip joint loading in fossil hominins and other primates.


Asunto(s)
Hueso Esponjoso/anatomía & histología , Cabeza Femoral/anatomía & histología , Hominidae/anatomía & histología , Animales , Evolución Biológica , Fémur/anatomía & histología , Gorilla gorilla/anatomía & histología , Articulación de la Cadera/anatomía & histología , Humanos , Locomoción/fisiología , Pan troglodytes/anatomía & histología , Pongo/anatomía & histología , Postura/fisiología
5.
J Anat ; 232(4): 641-656, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29344941

RESUMEN

Aspects of trabecular bone architecture are thought to reflect regional loading of the skeleton, and thus differ between primate taxa with different locomotor and postural modes. However, there are several systemic factors that affect bone structure that could contribute to, or be the primary factor determining, interspecific differences in bone structure. These systemic factors include differences in genetic regulation, sensitivity to loading, hormone levels, diet, and activity levels. Improved understanding of inter-/intraspecific variability, and variability across the skeleton of an individual, is required to interpret properly potential functional signals present within trabecular structure. Using a whole-region method of analysis, we investigated trabecular structure throughout the skeleton of humans and chimpanzees. Trabecular bone volume fraction (BV/TV), degree of anisotropy (DA) and trabecular thickness (Tb.Th) were quantified from high resolution micro-computed tomographic scans of the humeral and femoral head, third metacarpal and third metatarsal head, distal tibia, talus and first thoracic vertebra. We found that BV/TV is, in most anatomical sites, significantly higher in chimpanzees than in humans, suggesting a systemic difference in trabecular structure unrelated to local loading regime. Differences in BV/TV between the forelimb and hindlimb did not clearly reflect differences in locomotor loading in the study taxa. There were no clear systemic differences between the taxa in DA and, as such, this parameter might reflect function and relate to differences in joint loading. This systemic approach reveals both the pattern of variability across the skeleton and between taxa, and helps identify those features of trabecular structure that may relate to joint function.


Asunto(s)
Tipificación del Cuerpo , Hueso Esponjoso/ultraestructura , Pan troglodytes/anatomía & histología , Pan troglodytes/crecimiento & desarrollo , Variación Anatómica , Animales , Anisotropía , Femenino , Cabeza Femoral/anatomía & histología , Humanos , Cabeza Humeral/anatomía & histología , Locomoción , Masculino , Huesos del Metacarpo/anatomía & histología , Huesos Metatarsianos/anatomía & histología , Estadísticas no Paramétricas , Astrágalo/anatomía & histología , Vértebras Torácicas/anatomía & histología , Tibia/anatomía & histología , Tomografía Computarizada por Rayos X
6.
J Hum Evol ; 123: 1-23, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30072187

RESUMEN

Hand bone morphology is regularly used to link particular hominin species with behaviors relevant to cognitive/technological progress. Debates about the functional significance of differing hominin hand bone morphologies tend to rely on establishing phylogenetic relationships and/or inferring behavior from epigenetic variation arising from mechanical loading and adaptive bone modeling. Most research focuses on variation in cortical bone structure, but additional information about hand function may be provided through the analysis of internal trabecular structure. While primate hand bone trabecular structure is known to vary in ways that are consistent with expected joint loading differences during manipulation and locomotion, no study exists that has documented this variation across the numerous bones of the hand. We quantify the trabecular structure in 22 bones of the human hand (early/extant modern Homo sapiens) and compare structural variation between two groups associated with post-agricultural/industrial (post-Neolithic) and foraging/hunter-gatherer (forager) subsistence strategies. We (1) establish trabecular bone volume fraction (BV/TV), modulus (E), degree of anisotropy (DA), mean trabecular thickness (Tb.Th) and spacing (Tb.Sp); (2) visualize the average distribution of site-specific BV/TV for each bone; and (3) examine if the variation in trabecular structure is consistent with expected joint loading differences among the regions of the hand and between the groups. Results indicate similar distributions of trabecular bone in both groups, with those of the forager sample presenting higher BV/TV, E, and lower DA, suggesting greater and more variable loading during manipulation. We find indications of higher loading along the ulnar side of the forager sample hand, with high site-specific BV/TV distributions among the carpals that are suggestive of high loading while the wrist moves through the 'dart-thrower's' motion. These results support the use of trabecular structure to infer behavior and have direct implications for refining our understanding of human hand evolution and fossil hominin hand use.


Asunto(s)
Hueso Esponjoso/anatomía & histología , Huesos de la Mano/anatomía & histología , Estilo de Vida , Arqueología , Fenómenos Biomecánicos , Hueso Esponjoso/fisiología , Huesos de la Mano/fisiología , Humanos
7.
Am J Phys Anthropol ; 167(4): 713-736, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30159927

RESUMEN

OBJECTIVES: Trabecular bone structure is known to be influenced by joint loading during life. However, many additional variables have the potential to contribute to trabecular bone structure of an adult individual, including age, sex, body size, genetics, and overall activity level. There is little research into intraspecific variability in trabecular bone and ontogeny of trabecular bone structure, especially in nonhuman primates. MATERIALS AND METHODS: This study investigates trabecular structure in adult and immature chimpanzees from a single population using high-resolution microcomputed tomographic scans of the proximal humerus, proximal femur, and distal tibia. Trabecular bone volume fraction (BV/TV), trabecular thickness (Tb.Th), trabecular number (Tb.N), trabecular spacing (Tb.Sp), and degree of anisotropy (DA) were quantified in specific regions of adult and immature chimpanzees, and color maps were generated to visualize the distribution of BV/TV throughout the joint in the metaphysis of immature specimens. RESULTS: The results demonstrate that variability in adult trabecular structure cannot be explained by sex or body size. During ontogeny, there is a general increase in trabecular BV/TV and Tb.Th with age, and ratios of trabecular parameters between the fore- and hindlimb may be consistent with locomotor transitions during ontogeny. DISCUSSION: Variation in trabecular morphology among adult individuals is not related to sex or body size, and the factors contributing to intraspecific variability, such as overall activity levels and genetic differences, require further investigation. Trabecular ontogeny in chimpanzees differs from humans in some respects, most notably the absence of a high BV/TV at birth.


Asunto(s)
Hueso Esponjoso/anatomía & histología , Húmero/anatomía & histología , Huesos de la Pierna/anatomía & histología , Pan troglodytes/anatomía & histología , Animales , Antropología Física , Antropometría , Hueso Esponjoso/fisiología , Femenino , Húmero/fisiología , Imagenología Tridimensional , Huesos de la Pierna/fisiología , Locomoción/fisiología , Masculino , Pan troglodytes/fisiología , Microtomografía por Rayos X
9.
Am J Phys Anthropol ; 163(4): 784-805, 2017 08.
Artículo en Inglés | MEDLINE | ID: mdl-28542704

RESUMEN

OBJECTIVES: Internal bone structure, both cortical and trabecular bone, remodels in response to loading and may provide important information regarding behavior. The foot is well suited to analysis of internal bone structure because it experiences the initial substrate reaction forces, due to its proximity to the substrate. Moreover, as humans and apes differ in loading of the foot, this region is relevant to questions concerning arboreal locomotion and bipedality in the hominoid fossil record. MATERIALS AND METHODS: We apply a whole-bone/epiphysis approach to analyze trabecular and cortical bone in the distal tibia and talus of Pan troglodytes and Homo sapiens. We quantify bone volume fraction (BV/TV), degree of anisotropy (DA), trabecular thickness (Tb.Th), bone surface to volume ratio (BS/BV), and cortical thickness and investigate the distribution of BV/TV and cortical thickness throughout the bone/epiphysis. RESULTS: We find that Pan has a greater BV/TV, a lower BS/BV and thicker cortices than Homo in both the talus and distal tibia. The trabecular structure of the talus is more divergent than the tibia, having thicker, less uniformly aligned trabeculae in Pan compared to Homo. Differences in dorsiflexion at the talocrural joint and in degree of mobility at the talonavicular joint are reflected in the distribution of cortical and trabecular bone. DISCUSSION: Overall, quantified trabecular parameters represent overall differences in bone strength between the two species, however, DA may be directly related to joint loading. Cortical and trabecular bone distributions correlate with habitual joint positions adopted by each species, and thus have potential for interpreting joint position in fossil hominoids.


Asunto(s)
Hueso Esponjoso/anatomía & histología , Hueso Cortical/anatomía & histología , Pan troglodytes/anatomía & histología , Astrágalo/anatomía & histología , Tibia/anatomía & histología , Caminata/fisiología , Animales , Antropología Física , Humanos
10.
Am J Phys Anthropol ; 161(4): 603-619, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27500902

RESUMEN

OBJECTIVES: Humans display an 85-95% cross-cultural right-hand bias in skilled tasks, which is considered a derived behavior because such a high frequency is not reported in wild non-human primates. Handedness is generally considered to be an evolutionary byproduct of selection for manual dexterity and augmented visuo-cognitive capabilities within the context of complex stone tool manufacture/use. Testing this hypothesis requires an understanding of when appreciable levels of right dominant behavior entered the fossil record. Because bone remodels in vivo, skeletal asymmetries are thought to reflect greater mechanical loading on the dominant side, but incomplete preservation of external morphology and ambiguities about past loading environments complicate interpretations. We test if internal trabecular bone is capable of providing additional information by analyzing the thumb of Homo sapiens and Pan. MATERIALS AND METHODS: We assess trabecular structure at the distal head and proximal base of paired (left/right) first metacarpals using micro-CT scans of Homo sapiens (n = 14) and Pan (n = 9). Throughout each epiphysis we quantify average and local bone volume fraction (BV/TV), degree of anisotropy (DA), and elastic modulus (E) to address bone volume patterning and directional asymmetry. RESULTS: We find a right directional asymmetry in H. sapiens consistent with population-level handedness, but also report a left directional asymmetry in Pan that may be the result of postural and/or locomotor loading. CONCLUSION: We conclude that trabecular bone is capable of detecting right/left directional asymmetry, but suggest coupling studies of internal structure with analyses of other skeletal elements and cortical bone prior to applications in the fossil record.


Asunto(s)
Lateralidad Funcional/fisiología , Huesos del Metacarpo/anatomía & histología , Pan troglodytes/anatomía & histología , Pulgar/anatomía & histología , Animales , Antropología Física , Evolución Biológica , Fenómenos Biomecánicos/fisiología , Fósiles , Humanos , Huesos del Metacarpo/diagnóstico por imagen , Pulgar/diagnóstico por imagen , Microtomografía por Rayos X
11.
Curr Osteoporos Rep ; 14(6): 374-385, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27714581

RESUMEN

Beyond bone mineral density (BMD), bone quality designates the mechanical integrity of bone tissue. In vivo images based on X-ray attenuation, such as CT reconstructions, provide size, shape, and local BMD distribution and may be exploited as input for finite element analysis (FEA) to assess bone fragility. Further key input parameters of FEA are the material properties of bone tissue. This review discusses the main determinants of bone mechanical properties and emphasizes the added value, as well as the important assumptions underlying finite element analysis. Bone tissue is a sophisticated, multiscale composite material that undergoes remodeling but exhibits a rather narrow band of tissue mineralization. Mechanically, bone tissue behaves elastically under physiologic loads and yields by cracking beyond critical strain levels. Through adequate cell-orchestrated modeling, trabecular bone tunes its mechanical properties by volume fraction and fabric. With proper calibration, these mechanical properties may be incorporated in quantitative CT-based finite element analysis that has been validated extensively with ex vivo experiments and has been applied increasingly in clinical trials to assess treatment efficacy against osteoporosis.


Asunto(s)
Remodelación Ósea , Huesos/diagnóstico por imagen , Fenómenos Biomecánicos , Densidad Ósea , Huesos/anatomía & histología , Huesos/fisiología , Hueso Esponjoso/diagnóstico por imagen , Hueso Esponjoso/fisiología , Hueso Cortical/diagnóstico por imagen , Hueso Cortical/fisiología , Análisis de Elementos Finitos , Humanos , Tamaño de los Órganos , Estrés Mecánico , Tomografía Computarizada por Rayos X , Soporte de Peso
12.
J Appl Biomech ; 32(2): 210-4, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26540736

RESUMEN

The variety of experimental setups used during in vitro testing of distal radius fracture treatments impairs interstudy comparison and might lead to contradictory results. Setups particularly differ with respect to their boundary conditions, but the influence on the experimental outcome is unknown. The aim of this biomechanical study was to investigate the effects of 2 common boundary conditions on the biomechanical properties of an extra-articular distal radius fracture treated using volar plate osteosynthesis. Uniaxial compression tests were performed on 10 synthetic radii that were randomized into a proximally constrained group (ProxConst) or proximally movable group (ProxMove). The load was applied distally through a ball joint to enable distal fragment rotation. A significantly larger (ProxConst vs ProxMove) stiffness (671.6 ± 118.9 N·mm(-1) vs 259.6 ± 49.4 N·mm(-1)), elastic limit (186.2 ± 24.4 N vs 75.4 ± 20.2 N), and failure load (504.9 ± 142.5 N vs 200.7 ± 49.0 N) were found for the ProxConst group. The residual tilt did not differ significantly between the 2 groups. We concluded that the boundary conditions have a profound impact on the experimental outcome and should be considered more carefully in both study design and interstudy comparison.


Asunto(s)
Placas Óseas , Análisis de Falla de Equipo/métodos , Fijación Interna de Fracturas/instrumentación , Falla de Prótesis , Fracturas del Radio/fisiopatología , Fracturas del Radio/cirugía , Módulo de Elasticidad , Análisis de Falla de Equipo/instrumentación , Fijación Interna de Fracturas/métodos , Humanos , Técnicas In Vitro , Fracturas del Radio/diagnóstico , Estrés Mecánico , Resistencia a la Tracción , Resultado del Tratamiento , Soporte de Peso
13.
J Biomech Eng ; 137(1)2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25363247

RESUMEN

Mechanical properties of human trabecular bone play an important role in age-related bone fragility and implant stability. Microfinite element (lFE) analysis allows computing the apparent elastic properties of trabecular bone for use in homogenized FE (hFE) analysis,but the results depend unfortunately on the type of applied boundary conditions(BCs). In this study, 167 human femoral trabecular cubic regions with a side length of 5.3mm were extracted from three proximal femora and analyzed using lFE analysis to compare systematically their stiffness with kinematic uniform BCs (KUBCs) and periodicity-compatible mixed uniform BCs (PMUBCs). The obtained elastic constants were then used in the volume fraction and fabric-based orthotropic Zysset­Curnier model to identify their respective model parameters. As expected, PMUBCs lead to more compliant apparent elastic properties than KUBCs, especially in shear. The differences in stiffness decreased with bone volume fraction and mean intercept length (MIL). Unlike KUBCs, PMUBCs were sensitive to heterogeneity of the biopsies. The Zysset­Curnier model fitted the apparent elastic constants successfully in both cases with adjusted coefficients of determination (r2adj) of 0.986 for KUBCs and 0.975 for PMUBCs. The proper use of these BCs for hFE analysis of whole bones will need to be investigated in future work.


Asunto(s)
Elasticidad , Fémur , Análisis de Elementos Finitos , Anciano , Fenómenos Biomecánicos , Femenino , Fémur/anatomía & histología , Humanos , Masculino , Persona de Mediana Edad , Tamaño de los Órganos , Estrés Mecánico
14.
J Hum Evol ; 67: 60-75, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24496040

RESUMEN

Phalangeal curvature is a commonly used morphological feature for the interpretation of extant and fossil primate locomotor behaviour. Here, we build on a recent biomechanical study (Richmond, 2007) in two ways: first, we use a 3D micro-FE model, which models the real internal microstructure (i.e., cortical thickness and trabecular bone structure) and, second, we model four siamang third proximal phalanges. We test identical 2D homogenized FE models and two 3D micro-FE phalanx models that are mathematically straightened to isolate the biomechanical significance of curvature. We further investigate how varying the loading configuration (e.g., boundary constraints) and modeling (e.g., 2D versus 3D) affects the biomechanical behaviour of the phalanx. Finally, we examine how intraspecific variation in external and internal bony morphology affects the biomechanical behaviour of the phalanx. Simulation results demonstrate that the general pattern of strain and displacement is similar between the 3D micro-FE and 2D homogenized FE models but the absolute values differ substantially. The biomechanical behaviour of the 3D FE models more closely match the relative strain patterns from the validation experiment than the 2D homogenized FE models, indicating the 3D microstructure model is preferable. Varying the loading configuration can have dramatic effects on the biomechanical behaviour of the phalanx depending on individual morphology, but overall a cantilevered beam model is an equally valid, if not better, configuration for modeling the phalanx as other previously-proposed models. Variation in flexor ridge morphology has a substantial effect on phalanx strain; the taller the ridge, the less strain incurred by other regions of the palmar shaft. Finally, phalangeal curvature reduces overall strain experienced by the phalanx, but does not necessarily reduce bending or increase the compression-to-tension ratio. These results confirm the adaptive role of phalangeal curvature during flexed-finger grasping postures and demonstrate that modeling variation in cortical thickness and flexor ridge morphology improves the behaviour of the FE model, which has important implications for the functional interpretation of phalanx form.


Asunto(s)
Falanges de los Dedos de la Mano/anatomía & histología , Análisis de Elementos Finitos , Hylobatidae/anatomía & histología , Animales , Antropología Física , Fenómenos Biomecánicos , Femenino , Falanges de los Dedos de la Mano/fisiología , Hylobatidae/fisiología
15.
J Mech Behav Biomed Mater ; 152: 106318, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38290394

RESUMEN

Trabecular bone structure is a complex microstructure consisting of rods and plates, which poses challenges for its mechanical characterization. Digital image correlation (DIC) offers the possibility to characterize the strain response on the surface of trabecular bone. This study employed DIC equipped with a telecentric lens to investigate the strain state of individual trabeculae within their trabecular structure by assessing the longitudinal strain of the trabeculae at both the middle and near the edges of the trabeculae. Due to the high-resolution of the used DIC system, local surface strain of trabeculae was analyzed too. Lastly, the correlation between longitudinal trabecular strain and the orientation and slenderness of the trabeculae was investigated. The results showed that the strain magnification close to the edge of the trabeculae was higher and reached up to 8-folds the strain along the middle of the trabeculae. On the contrary, no strain magnification was found for most of the trabeculae between the longitudinal trabecular strain along the middle of the trabeculae and the globally applied strain. High-resolution full-field strain maps were obtained on the surface of trabeculae showing heterogeneous strain distribution with increasing load. No significant correlation was found between longitudinal trabecular strain and its orientation or slenderness. These findings and the applied methodology can be used to broaden our understanding of the deformation mechanisms of trabeculae within the trabecular network.

16.
J Mech Behav Biomed Mater ; 157: 106634, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38945119

RESUMEN

Micro finite-element (µFE) simulations serve as a crucial research tool to assist laboratory experiments in the biomechanical assessment of screw anchorage in bone. However, accurately modelling the interface between bone and screw threads at the microscale poses a significant challenge. Currently, the gold-standard approach involves employing computationally intensive physical contact models to simulate this interface. This study compared nonlinear µFE predictions of deformations, whole-construct stiffness, maximum force and damage patterns of three different computationally efficient simplified interface approaches to the general contact interface in Abaqus Explicit, which was defined as gold-standard and reference model. The µCT images (resolution: 32.8 µm) of two human radii with varying bone volume fractions were utilized and a screw was virtually inserted up to 50% and 100% of the volar-dorsal cortex distance. Materially nonlinear µFE models were generated and loaded in tension, compression and shear. In a first step, the common simplification of using a fully-bonded interface was compared to the general contact interface, revealing overestimations of whole-construct stiffness (19% on average) and maximum force (26% on average), along with inaccurate damage pattern replications. To enhance predictions, two additional simplified interface models were compared: tensionally strained element deletion (TED) and a novel modification of TED (TED-M). TED deletes interface elements strained in tension based on a linear-elastic simulation before the actual simulation. TED-M extends the remaining contact interface of TED by incorporating neighboring elements to the contact area. Both TED and TED-M reduced the errors in whole-construct stiffness and maximum force and improved the replication of the damage distributions in comparison to the fully-bonded approach. TED was better in predicting whole-construct stiffness (average error of 1%), while TED-M showed lowest errors in maximum force (1% on average). In conclusion, both TED and TED-M offer computationally efficient alternatives to physical contact modelling, although the fully-bonded interface may deliver sufficiently accurate predictions for many applications.


Asunto(s)
Tornillos Óseos , Análisis de Elementos Finitos , Humanos , Dinámicas no Lineales , Fenómenos Mecánicos , Fenómenos Biomecánicos , Ensayo de Materiales , Estrés Mecánico , Microtomografía por Rayos X
17.
J Mech Behav Biomed Mater ; 150: 106259, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38039773

RESUMEN

The response of bone tissue to mechanical load is complex and includes plastic hardening, viscosity and damage. The quantification of these effects plays a mayor role in bone research and in biomechanical clinical trials as to better understand related diseases. In this study, the damage growth in individual wet human trabeculae subjected to cyclic overloading is quantified by inverse rheological modeling. Therefore, an already published rheological material model, that includes linear elasticity, plasticity and viscosity is extended by a damage law. The model is utilized in an optimization process to identify the corresponding material parameters and damage growth in single human trabeculae under tensile load. Results show that the damage model is leading to a better fit of the test data with an average root-mean-square-error (RMSE) of 2.52 MPa compared to the non-damage model with a RMSE of 3.03 MPa. Although this improvement is not significant, the damage model qualitatively better represents the data as it accounts for the visible stiffness reduction along the load history. It returns realistic stiffness values of 11.92 GPa for the instantaneous modulus and 5.73 GPa for the long term modulus of wet trabecular human bone. Further, the growth of damage in the tissue along the load history is substantial, with values above 0.8 close to failure. The relative loss of stiffness per cycle is in good agreement with comparable literature. Inverse rheological modeling proves to be a valuable tool for quantifying complex constitutive behavior from a single mechanical measurement. The evolution of damage in the tissue can be identified continuously over the load history and separated from other effects.


Asunto(s)
Huesos , Hueso Esponjoso , Humanos , Estrés Mecánico , Elasticidad , Reología , Fenómenos Biomecánicos
18.
Med Eng Phys ; 126: 104143, 2024 04.
Artículo en Inglés | MEDLINE | ID: mdl-38621845

RESUMEN

Primary implant stability, which refers to the stability of the implant during the initial healing period is a crucial factor in determining the long-term success of the implant and lays the foundation for secondary implant stability achieved through osseointegration. Factors affecting primary stability include implant design, surgical technique, and patient-specific factors like bone quality and morphology. In vivo, the cyclic nature of anatomical loading puts osteosynthesis locking screws under dynamic loads, which can lead to the formation of micro cracks and defects that slowly degrade the mechanical connection between the bone and screw, thus compromising the initial stability and secondary stability of the implant. Monotonic quasi-static loading used for testing the holding capacity of implanted screws is not well suited to capture this behavior since it cannot capture the progressive deterioration of peri­implant bone at small displacements. In order to address this issue, this study aims to determine a critical point of loss of primary implant stability in osteosynthesis locking screws under cyclic overloading by investigating the evolution of damage, dissipated energy, and permanent deformation. A custom-made test setup was used to test implanted 2.5 mm locking screws under cyclic overloading test. For each loading cycle, maximum forces and displacement were recorded as well as initial and final cycle displacements and used to calculate damage and energy dissipation evolution. The results of this study demonstrate that for axial, shear, and mixed loading significant damage and energy dissipation can be observed at approximately 20 % of the failure force. Additionally, at this load level, permanent deformations on the screw-bone interface were found to be in the range of 50 to 150 mm which promotes osseointegration and secondary implant stability. This research can assist surgeons in making informed preoperative decisions by providing a better understanding of the critical point of loss of primary implant stability, thus improving the long-term success of the implant and overall patient satisfaction.


Asunto(s)
Placas Óseas , Fijación Interna de Fracturas , Humanos , Fenómenos Biomecánicos , Fijación Interna de Fracturas/métodos , Tornillos Óseos , Fenómenos Mecánicos
19.
Am J Biol Anthropol ; 183(3): e24695, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36790736

RESUMEN

OBJECTIVES: Recent studies have associated subarticular trabecular bone distribution in the extant hominid first metacarpal (Mc1) with observed thumb use, to infer fossil hominin thumb use. Here, we analyze the entire Mc1 to test for interspecific differences in: (1) the absolute volume of trabecular volume fraction, (2) the distribution of the deeper trabecular network, and (3) the distribution of trabeculae in the medullary cavity, especially beneath the Mc1 disto-radial flange. MATERIALS AND METHODS: Trabecular bone was imaged using micro-computed tomography in a sample of Homo sapiens (n = 11), Pan paniscus (n = 10), Pan troglodytes (n = 11), Gorilla gorilla (n = 10) and Pongo sp., (n = 7). Using Canonical Holistic Morphometric Analysis (cHMA), we tested for interspecific differences in the trabecular bone volume fraction (BV/TV) and its relative distribution (rBV/TV) throughout the Mc1, including within the head, medullary cavity, and base. RESULTS: P. paniscus had the highest, and H. sapiens the lowest, BV/TV relative to other species. rBV/TV distribution statistically distinguished the radial concentrations and lack of medullary trabecular bone in the H. sapiens Mc1 from all other hominids. H. sapiens and, to a lesser extent, G. gorilla also had a significantly higher trabecular volume beneath the disto-radial flange relative to other hominids. DISCUSSION: These results are consistent with differences in observed thumb use in these species and may also reflect systemic differences in bone volume fraction. The trabecular bone extension into the medullary cavity and concentrations beneath the disto-radial flange may represent crucial biomechanical signals that will aid in the inference of fossil hominin thumb use.


Asunto(s)
Hominidae , Huesos del Metacarpo , Humanos , Animales , Huesos del Metacarpo/diagnóstico por imagen , Pulgar , Microtomografía por Rayos X , Pan troglodytes , Gorilla gorilla , Pongo , Pan paniscus
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA