Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Am Surg ; 68(6): 530-3; discussion 533-4, 2002 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-12079134

RESUMEN

Incisional hernias after abdominal operations are a significant cause of long-term morbidity and have been reported to occur in 3 to 20 per cent of laparotomy incisions. Traditional primary suture closure repair is plagued with up to a 50 per cent recurrence rate. With the introduction of prosthetic mesh repair recurrence decreased, but complications with mesh placement emerged ushering in the development of laparoscopic incisional herniorrhaphy. The records of patients who underwent laparoscopic incisional hernia repair between June 1, 1995 and September 1, 2001 were reviewed. Patient demographics, hernia defect size, recurrence, operative time, and procedure-related complications were evaluated. Fifty patients (22 male and 28 female, mean age 57 years with range of 24-83) were scheduled for laparoscopic incisional hernia repair between June 1, 1995 and September 1, 2001. The average patient was obese with a mean body mass index of 35.8 kg/m2 (range 16-57 kg/m2). Two patients (4%) had primary ventral hernias. Forty-eight patients (96%) had incisional hernias with 22 (46%) of these previously repaired with prosthetic mesh. Mean defect size was 206.1 cm2 (range 48-594 cm2). The average mesh size was 510.2 cm2 (range 224-1050 cm2). Gore-Tex DualMesh and Bard Composite Mesh were used in 84 and 16 per cent of the repairs, respectively. Mean operating time was 97 minutes. There were no deaths. Complications were seen in 12 per cent patients (six occurrences) and included two small bowel enterotomies, a symptomatic seroma requiring aspirate, a mesh reaction requiring a short course of intravenous antibiotics, and trocar site pain (two patients). There were no recurrences during a mean follow-up of 41 months (range 3-74 months). We conclude that laparoscopic incisional herniorrhaphy offers a safe and effective repair for large primary and recurrent ventral hernia with low morbidity.


Asunto(s)
Hernia Ventral/cirugía , Laparoscopía/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Hernia Ventral/complicaciones , Hernia Ventral/etiología , Humanos , Laparotomía/efectos adversos , Masculino , Persona de Mediana Edad , Obesidad/complicaciones , Recurrencia , Estudios Retrospectivos , Mallas Quirúrgicas
2.
J Trauma ; 55(1): 74-9, 2003 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-12855884

RESUMEN

BACKGROUND: There are many reasons for hypotension in trauma patients with multiple injuries; one uncommon source is facial fractures. The treatment algorithm is volume replacement and local control of the bleeding. A retrospective study was undertaken to evaluate the treatment of patients with life-threatening hemorrhage secondary to facial fractures, and to develop a treatment algorithm. METHODS: A retrospective chart review was undertaken to determine the incidence of hemorrhagic shock in patients with facial fractures exclusive of others sources, and the use of transcatheter arterial embolization to control the bleeding was evaluated. RESULTS: Over a 4-year period, 7562 patients were treated at Palmetto Richland Memorial Hospital, a Level I trauma center. There were 912 patients with facial injuries, with 11 of these patients presenting with life-threatening hemorrhage secondary to facial fractures. The incidence of life-threatening hemorrhage from facial fracture was 1.2%. The mechanism of injury was blunt in 10 patients and penetrating in 1. The blunt injuries resulted from six motor vehicles crashes, three motorcycle crashes, and one plane crash. The one penetrating injury was a shotgun blast. There were six patients with Le Fort III fractures, two patients with Le Fort II fractures, and three patients with a combination of Le Fort II and III fractures bilaterally. The average volume infused before the embolization was 7 L; this included blood and crystalloid. There were four complications: two minor groin hematomas, one partial necrosis of the tongue, and one facial nerve palsy. There were two deaths, both secondary to concomitant intracranial injury as a result of blunt trauma. CONCLUSION: The incidence of severe hemorrhage secondary to facial fractures is rare; however, it can be life threatening. When common modalities of treatment such as pressure, packing, and correction of coagulopathy fail to control the hemorrhage, transcatheter arterial embolization offers a safe alternative to surgical control.


Asunto(s)
Embolización Terapéutica/métodos , Hemorragia/etiología , Arteria Maxilar/diagnóstico por imagen , Traumatismos Maxilofaciales/complicaciones , Centros Traumatológicos/estadística & datos numéricos , Algoritmos , Hemorragia/epidemiología , Hemorragia/terapia , Humanos , Incidencia , Traumatismos Maxilofaciales/mortalidad , Radiografía , Estudios Retrospectivos , South Carolina/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA