Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Catheter Cardiovasc Interv ; 89(3): 445-451, 2017 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-27218599

RESUMEN

OBJECTIVES: We sought to examine whether baseline diastolic dysfunction (DD) is associated with increased mortality in patients who develop aortic insufficiency (AI) after transcatheter aortic valve replacement (TAVR). BACKGROUND: Significant post-TAVR AI is associated with increased mortality, likely secondary to adverse hemodynamics secondary to volume overload and decreased LV compliance from chronic pressure overload. However, the effect of baseline DD on outcomes of patients with post-TAVR AI has not been studied. METHODS: A total of 195 patients undergoing TAVR were included in the study. Patients with moderate-to-severe mitral stenosis, prior mitral valve replacement or atrial fibrillation were excluded. DD was classified at baseline by a 2-step approach as recommended by the American Society of Echocardiography while AI was evaluated 30 days post-TAVR. Follow up data up to 2 years post-TAVR was used in survival analysis. RESULTS: Patients with severe baseline DD who developed ≥mild post-TAVR AI had increased mortality compared to all other patients (HR = 3.89, CI: 1.76-8.6, P = 0.001), which remained significant after adjusting for post-TAVR AI, pre-TAVR AI, baseline mitral regurgitation, ejection fraction, pulmonary artery pressure, creatinine clearance and history of stroke. CONCLUSIONS: Even mild post-TAVR AI may have a negative impact on outcomes of patients with underlying severe DD. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/terapia , Válvula Aórtica , Cateterismo Cardíaco/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Disfunción Ventricular Izquierda/complicaciones , Función Ventricular Izquierda , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/mortalidad , Insuficiencia de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/mortalidad , Diástole , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Estimación de Kaplan-Meier , Masculino , Modelos de Riesgos Proporcionales , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/mortalidad , Disfunción Ventricular Izquierda/fisiopatología
2.
J Heart Valve Dis ; 25(3): 301-308, 2016 05.
Artículo en Inglés | MEDLINE | ID: mdl-27989040

RESUMEN

BACKGROUND: Paravalvular aortic regurgitation (PAR) remains a common complication following transcatheter aortic valve replacement (TAVR), and has been associated with increased mortality. Adverse left ventricular (LV) remodelling has been reported in patients with post-TAVR PAR, but the association between adverse LV remodeling and increased mortality remains unclear. The aim of the present study was to examine the association between PAR, LV remodeling and mortality following TAVR in a non-PARTNER (Placement of Aortic Transcatheter Valves) trial population. METHODS: A total of 195 patients that underwent TAVR was included in the study. The LV ejection fraction (LVEF), LV mass index (LVMI), LV internal dimension at systole (LVIDs) and diastole (LVIDd) were compared between patients with different degrees of PAR at baseline, and at one month and one year after TAVR. Survival analysis was performed for different degrees of PAR and LV remodeling. RESULTS: PAR ≥moderate was associated with increased mortality (HR 4.58 [1.80-11.63], p = 0.001), but PAR >mild was not. The LVIDd and LVIDs were persistently increased at one year after TAVR in patients with PAR >mild compared to those with PAR ≤mild (5.9 ± 0.8 cm versus 5.4 ± 0.7 cm, p = 0.02 and 4.4 ± 0.8 cm versus 3.9 ± 0.8, p = 0.03, respectively). The LVEF was improved similarly between the two groups at one year after TAVR (p = 0.1). Patients with PAR ≥moderate had significantly more adverse LV remodeling at one month after TAVR in terms of LVIDd, LVIDs, and LVMI. The degree of remodeling as expressed in terms of LVIDd, LVIDs, LVMI and LVEF changes from baseline did not have a direct impact on mortality. CONCLUSIONS: A worse PAR was associated with more adverse LV remodeling and a higher mortality after TAVR in a non-PARTNER patient population.


Asunto(s)
Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/mortalidad , Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Función Ventricular Izquierda , Remodelación Ventricular , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico , Insuficiencia de la Válvula Aórtica/fisiopatología , Bases de Datos Factuales , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Modelos de Riesgos Proporcionales , Recuperación de la Función , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Volumen Sistólico , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA