Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 425
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Am J Hum Genet ; 108(9): 1578-1589, 2021 09 02.
Artículo en Inglés | MEDLINE | ID: mdl-34265237

RESUMEN

Thoracic aortic aneurysm (TAA) is characterized by dilation of the aortic root or ascending/descending aorta. TAA is a heritable disease that can be potentially life threatening. While 10%-20% of TAA cases are caused by rare, pathogenic variants in single genes, the origin of the majority of TAA cases remains unknown. A previous study implicated common variants in FBN1 with TAA disease risk. Here, we report a genome-wide scan of 1,351 TAA-affected individuals and 18,295 control individuals from the Cardiovascular Health Improvement Project and Michigan Genomics Initiative at the University of Michigan. We identified a genome-wide significant association with TAA for variants within the third intron of TCF7L2 following replication with meta-analysis of four additional independent cohorts. Common variants in this locus are the strongest known genetic risk factor for type 2 diabetes. Although evidence indicates the presence of different causal variants for TAA and type 2 diabetes at this locus, we observed an opposite direction of effect. The genetic association for TAA colocalizes with an aortic eQTL of TCF7L2, suggesting a functional relationship. These analyses predict an association of higher expression of TCF7L2 with TAA disease risk. In vitro, we show that upregulation of TCF7L2 is associated with BCL2 repression promoting vascular smooth muscle cell apoptosis, a key driver of TAA disease.


Asunto(s)
Aneurisma de la Aorta Torácica/genética , Diabetes Mellitus Tipo 2/genética , Células Endoteliales/metabolismo , Proteínas Proto-Oncogénicas c-bcl-2/genética , Sitios de Carácter Cuantitativo , Proteína 2 Similar al Factor de Transcripción 7/genética , Aorta/metabolismo , Aorta/patología , Aneurisma de la Aorta Torácica/metabolismo , Aneurisma de la Aorta Torácica/patología , Estudios de Casos y Controles , Caspasa 3/genética , Caspasa 3/metabolismo , Diabetes Mellitus Tipo 2/metabolismo , Diabetes Mellitus Tipo 2/patología , Células Endoteliales/patología , Regulación de la Expresión Génica , Genoma Humano , Estudio de Asociación del Genoma Completo , Humanos , Intrones , Michigan , Músculo Liso Vascular/metabolismo , Músculo Liso Vascular/patología , Mutación , Proteínas Proto-Oncogénicas c-bcl-2/metabolismo , Proteína 2 Similar al Factor de Transcripción 7/metabolismo , Proteína X Asociada a bcl-2/genética , Proteína X Asociada a bcl-2/metabolismo
2.
Catheter Cardiovasc Interv ; 103(3): 490-498, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38329195

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) has changed the landscape of aortic stenosis (AS) management. AIM: To describe and evaluate geographic variation in AS treatment and outcomes among a sample of Medicare beneficiaries. METHODS: A retrospective analysis of administrative claims data was conducted on a 20% sample of Medicare fee-for-service beneficiaries aged 65 and older with a diagnosis of AS (2015-2018). Estimates of demographic, comorbidity, and healthcare resources were obtained from Medicare claims and the Dartmouth Atlas of Health Care at the hospital referral region (HRR), which represents regional tertiary medical care markets. Linear regression was used to explain HRR-level variation in rates of surgical aortic valve replacement (SAVR) and TAVR, and 1-year mortality and readmission rates. RESULTS: A total of 740,899 beneficiaries with AS were identified with a median prevalence of AS of 39.9 per 1000 Medicare beneficiary years. The average HRR-level rate of SAVR was 26.3 procedures per 1000 beneficiary years and the rate of TAVR was 20.3 procedures per 1000 beneficiary years. HRR-level comorbidities and number of TAVR centers were associated with a lower SAVR rate. Demographics and comorbidities explained most of the variation in HRR-level 1-year mortality (15.2% and 18.8%) and hospitalization rates (20.5% and 16.9%), but over half of the variation remained unexplained. CONCLUSION: Wide regional variation in the treatment and outcomes of AS was observed but were largely unexplained by patient factors and healthcare utilization. Understanding the determinants of AS treatment and outcomes can inform population health efforts for these patients.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Anciano , Estados Unidos/epidemiología , Medicare , Estudios Retrospectivos , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Constricción Patológica , Factores de Riesgo
3.
J Surg Res ; 296: 472-480, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38320367

RESUMEN

INTRODUCTION: We aimed to investigate the association between renal dysfunction at discharge and long-term survival in acute type A aortic dissection (ATAAD) patients following surgery. METHODS: From 2000 to 2021, 784 patients underwent aortic repair for an ATAAD. Patients were stratified based on creatinine (Cr) level at discharge alive or dead: normal Cr (n = 582) and elevated Cr defined as >1.3 mg/dL for males and >1.0 mg/dL for females or on dialysis at discharge (n = 202). RESULTS: Preoperatively, both groups had similar rates of comorbidities except for the elevated-Cr group which had more diabetes, chronic obstructive pulmonary disease, and chronic and acute renal insufficiency. Both groups had similar open ATAAD repair procedures. Postoperative outcomes in the elevated-Cr group were significantly worse, including six times higher operative mortality (20% versus 3.4%, P < 0.0001). The landmark long-term survival after discharge alive was significantly worse in the elevated-Cr group than the normal-Cr group (10-y survival: 48% versus 69%, P = 0.0009). The elevated Cr on dialysis at discharge group had significantly worse five-year survival (40%) than the elevated Cr not on dialysis at discharge group (80%, P = 0.02) and the normal-Cr group (87%, P < 0.0001). Additionally, the elevated Cr not on dialysis had a worse five-year survival than the normal-Cr group (80% versus 87%, P = 0.02). Elevated Cr at discharge on dialysis was a significant risk factor for late mortality (hazard ratio = 4.22, 95% confidence interval: [2.07, 8.61], P < 0.0001). CONCLUSIONS: Renal dysfunction at discharge was associated with significantly decreased short-term and long-term survival following open ATAAD repair. Surgeons should aggressively prevent renal dysfunction, especially new-onset dialysis, at discharge as it is correlated with significantly worse short-term and long-term outcomes.


Asunto(s)
Lesión Renal Aguda , Disección Aórtica , Implantación de Prótesis Vascular , Masculino , Femenino , Humanos , Alta del Paciente , Estudios Retrospectivos , Disección Aórtica/cirugía , Diálisis Renal , Factores de Riesgo , Lesión Renal Aguda/etiología , Lesión Renal Aguda/terapia , Resultado del Tratamiento
4.
Ann Vasc Surg ; 104: 147-155, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38492730

RESUMEN

BACKGROUND: Endovascular repair of blunt thoracic aortic injury (BTAI) has dramatically reduced the morbidity and mortality of intervention. Injuries requiring zone 2 coverage of the aorta traditionally require left subclavian artery (LSA) sacrifice or open revascularization. Furthermore, these injuries are associated with an increased risk of in-hospital mortality and long-term morbidity. Here we report 1-year outcomes of total endovascular repair of BTAI with the GORE® TAG® Thoracic Branch Endoprosthesis for LSA preservation. METHODS: Across 34 investigative sites, 9 patients with BTAI requiring LSA coverage were enrolled in a nonrandomized, prospective study of a single-branched aortic endograft. The thoracic branch endoprosthesis device allows for graft placement proximal to the LSA and incorporates a single side branch for LSA perfusion. RESULTS: This initial cohort included 8 male and 1 female patient with a median age of 43 (22, 76) and 12 months of follow-up. Five total years of follow-up are planned. All participants had grade 3 BTAI. All procedures took place between 2018 and 2019. The median injury severity score was 2 (0, 66). The median procedure time was 109 min (78, 162). All aortic injuries were repaired under general anesthesia and with heparinization. A spinal drain was used in one patient. Post-deployment balloon angioplasty was conducted in one case at the distal landing zone. There was one asymptomatic LSA branch occlusion 6 months after repair. It was attributed to the purposeful proximal deployment of the branch stent to accommodate an early vertebral takeoff. The occlusion did not require revascularization. There were no strokes, mortalities, or aortic adverse events (migration, endoleak, native aortic expansion, dissection, or thrombosis) through 12 months of follow-up. CONCLUSIONS: Initial cohort outcomes suggest that endovascular repair of zone 2 BTAI is feasible and has favorable outcomes using the thoracic branch device with LSA preservation. Additional cases and longer-term follow-up are required for a definitive assessment of the device's safety and durability in traumatic aortic injuries.


Asunto(s)
Aorta Torácica , Implantación de Prótesis Vascular , Prótesis Vascular , Procedimientos Endovasculares , Diseño de Prótesis , Lesiones del Sistema Vascular , Heridas no Penetrantes , Humanos , Masculino , Heridas no Penetrantes/cirugía , Heridas no Penetrantes/diagnóstico por imagen , Femenino , Lesiones del Sistema Vascular/cirugía , Lesiones del Sistema Vascular/diagnóstico por imagen , Lesiones del Sistema Vascular/mortalidad , Lesiones del Sistema Vascular/etiología , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Aorta Torácica/cirugía , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/lesiones , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Adulto , Resultado del Tratamiento , Persona de Mediana Edad , Factores de Tiempo , Estudios Prospectivos , Adulto Joven , Anciano , Traumatismos Torácicos/cirugía , Traumatismos Torácicos/diagnóstico por imagen , Traumatismos Torácicos/mortalidad , Estados Unidos , Stents , Factores de Riesgo
5.
Circulation ; 146(15): 1149-1158, 2022 10 11.
Artículo en Inglés | MEDLINE | ID: mdl-36148651

RESUMEN

BACKGROUND: Hybrid debranching repair of pararenal and thoracoabdominal aortic aneurysms was initially designed as a better alternative to standard open repair, addressing the limitations of endovascular repair involving the visceral aorta. We reviewed the collective outcomes of hybrid debranching repairs using extra-anatomic, open surgical debranching of the renal-mesenteric arteries, followed by endovascular aortic stenting. METHODS: Data from patients who underwent hybrid repair in 14 North American institutions during 10 years were retrospectively reviewed. Society of Vascular Surgery scores were used to assess comorbidity risk. Early and late outcomes, including mortality, morbidity, reintervention, and patency were analyzed. RESULTS: A total of 208 patients (118 male; mean age, 71±8 years old) were treated by hybrid repair with extraanatomic reconstruction of 657 renal and mesenteric arteries (mean 3.2 vessels/patient). Mean aneurysm diameter was 6.6±1.3 cm. Thoracoabdominal aortic aneurysms were identified in 163 (78%) patients and pararenal aneurysms in 45 (22%). A single-stage repair was performed in 92 (44%) patients. The iliac arteries were the most common source of inflow (n=132; 63%), and most (n=150; 72%) had 3 or more bypasses. There were 30 (14%) early deaths, ranging widely across sites (0%-21%). A Society of Vascular Surgery comorbidity score >15 was the primary predictor of early mortality (P<0.01), whereas mortality was 3% in a score ≤9. Early complications occurred in 140 (73%) patients and included respiratory complications in 45 patients (22%) and spinal cord ischemia in 22 (11%), of whom 10 (45%) fully recovered. At 5 years, survival was 61±5%, primary graft patency was 90±2%, and secondary patency was 93±2%. The most significant predictor of late mortality was renal insufficiency (P<0.0001). CONCLUSIONS: Mortality after hybrid repair and visceral debranching is highly variable by center, but strongly affected by preoperative comorbidities and the centers' experience with the technique. With excellent graft patency at 5 years, the outcomes of hybrid repair done at centers of excellence and in carefully selected patients may be comparable (or better) than traditional open or even totally endovascular approaches. However, in patients already considered as high-risk for surgery, it may not offer better outcomes.


Asunto(s)
Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Anciano , Aorta/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , América del Norte , Complicaciones Posoperatorias/etiología , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
6.
J Vasc Surg ; 78(4): 912-919.e1, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37327951

RESUMEN

BACKGROUND: Thoracic endovascular aortic repair (TEVAR) has evolved as the standard for treating complicated acute type B aortic dissection (ATBAD). Acute kidney injury (AKI) is a common complication in critically ill patients and is commonly observed in patients with ATBAD. The purpose of the study was to characterize AKI after TEVAR. METHODS: All patients who underwent TEVAR for ATBAD from 2011 through 2021 were identified using the International Registry of Acute Aortic Dissection. The primary end point was AKI. A generalized linear model analysis was performed to identify a factor associated with postoperative AKI. RESULTS: A total of 630 patients presented with ATBAD and underwent TEVAR. The indication for TEVAR was complicated ATBAD in 64.3%, high-risk uncomplicated ATBAD in 27.6%, and uncomplicated ATBAD in 8.1%. Of 630 patients, 102 (16.2%) developed postoperative AKI (AKI group) and 528 patients (83.8%) did not (non-AKI group). The most common indication for TEVAR was malperfusion (37.5%). In-hospital mortality was significantly higher in the AKI group (18.6% vs 4%; P < .001). Postoperatively, cerebrovascular accident, spinal cord ischemia, limb ischemia, and prolonged ventilation were more commonly observed in the AKI group. The expected mortality was similar at 2 years between the two groups (P = .51). Overall, the preoperative AKI was observed in 95 (15.7%) in the entire cohort consisting of 60 (64.5%) in the AKI group and 35 (6.8%) in the non-AKI group. A history of CKD (odds ratio, 4.6; 95% confidence interval, 1.5-14.1; P = .01) and preoperative AKI (odds ratio, 24.1; 95% confidence interval, 10.6-55.0; P < .001) were independently associated with postoperative AKI. CONCLUSIONS: The incidence of postoperative AKI was 16.2% in patients undergoing TEVAR for ATBAD. Patients with postoperative AKI had a higher rate of in-hospital morbidities and mortality than those without. A history of CKD and preoperative AKI were independently associated with postoperative AKI.


Asunto(s)
Lesión Renal Aguda , Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Insuficiencia Renal Crónica , Humanos , Reparación Endovascular de Aneurismas , Implantación de Prótesis Vascular/efectos adversos , Resultado del Tratamiento , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/complicaciones , Procedimientos Endovasculares/efectos adversos , Estudios Retrospectivos , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Lesión Renal Aguda/diagnóstico , Lesión Renal Aguda/epidemiología , Lesión Renal Aguda/etiología , Insuficiencia Renal Crónica/complicaciones , Factores de Riesgo , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/cirugía
7.
J Endovasc Ther ; 30(4): 550-560, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35587698

RESUMEN

BACKGROUND: Operative mortality for type A aortic dissection is still 10-20% at centers of excellence. Additionally, 10-20% are not considered as viable candidates for open surgical repair and not offered life-saving emergency surgery. ARISE is a multicenter investigation evaluating the novel GORE® Ascending Stent Graft (ASG; Flagstaff, AZ). OBJECTIVE: The purpose of this study is to assess early feasibility of using these investigational devices to treat ascending aortic dissection. METHODS: This a prospective, multicenter, non-randomized, single-arm study that enrolls patients at high surgical risk with appropriate anatomical requirements based on computed tomography imaging at 7 of 9 US sites. Devices are delivered transfemorally under fluoroscopic guidance. Primary endpoint is all-cause mortality at 30 days. Secondary endpoints include major adverse cardiovascular and cerebrovascular events (MACCE) at 30 days, 6 months, and 12 months. RESULTS: Nineteen patients were enrolled with a mean age of 75.7 years (range 47-91) and 11 (57.9%) were female. Ten (52.6%) had DeBakey type I disease, and the rest were type II. Sixteen (84.2%) of the patients were acute. Patients were treated with safe access, (7/19 (36.8%) percutaneous, 10/19 (52.6%) transfemoral, 2/19 (10.5%) iliac conduit), delivery, and deployment completed in all cases. Median procedure time was 154 mins (range 52-392) and median contrast used was 111 mL (range 75-200). MACCE at 30 days occurred in 5 patients including mortality 3/19 (15.8%), disabling stroke in 1/19 (5.3%), and myocardial infarction in 1/19 (5.3%). CONCLUSION: Results from the ARISE early feasibility study of a specific ascending stent graft device to treat ascending aortic dissection are promising.


Asunto(s)
Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Disección de la Aorta Ascendente , Procedimientos Endovasculares , Humanos , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Masculino , Prótesis Vascular , Estudios Prospectivos , Resultado del Tratamiento , Diseño de Prótesis , Stents , Complicaciones Posoperatorias/etiología , Aneurisma de la Aorta Torácica/cirugía
8.
J Endovasc Ther ; : 15266028231208644, 2023 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-37933168

RESUMEN

PURPOSE: Patients with complicated ascending aortic pathology, including patients with acute type A aortic dissection may be at extreme risk for open repair. Thoracic endovascular aortic repair (TEVAR), infrequently used for the ascending aorta, may be considered an alternative in this setting. We describe early results for emergency and compassionate (E&C) use of a novel endograft, specifically designed for use to treat pathology of the ascending aorta. MATERIALS AND METHODS: This case series evaluated 19 patients (mean age, 68.84±13.12 years; 57.9% female) treated with ascending TEVAR for acute and chronic acute (4), subacute (1), or chronic (1) aortic dissection or pseudoaneurysm (13). Six of the 19 patients (31.5%) were treated under compassionate use and 13 patients (68.4%) were treated under the emergency use exemption. Ten patients (52.6%) received additional devices to extend treatment into the arch and descending aorta. RESULTS: Device delivery was achieved in all patients (100%). Thirty-day mortality and stroke occurred in 3 patients (15.8%) and in 1 patient (5.3%), respectively. In 1 patient (5.3%), with an Unanticipated Adverse Device Event, the aorta ruptured when the endograft eroded into the adventitial portion of dissection site at the posterior aspect of the ascending wall. Devices were explanted in 2 patients (10.5%), 353 and 610 days after the index procedure, respectively. Six patients had endoleaks (31.6%), including type I (n=2, 10.5%), type II endoleaks (n=3, 15.8%), and indeterminate endoleak (n=1, 5.3%). CONCLUSIONS: Delivery and deployment of a novel ascending thoracic stent graft with or without an additional branched arch extension is feasible in patients with complex anatomy and pathology, including acute aortic dissection and pseudoaneurysm. Additional experience with this novel device will further refine the patient population most suitable for endovascular ascending aortic repair for these pathologies. CLINICAL IMPACT: This study describes a novel stent graft specifically designed for treatment of ascending aortic pathology, including acute type A dissection. The patients described in this series constituted a group outside the formal US FDA sponsored clinical trial, and were those accepted as part of an emergency and compassionate use basis.

9.
Eur J Vasc Endovasc Surg ; 66(6): 775-782, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37201718

RESUMEN

OBJECTIVE: To describe the trends in management and outcomes of patients with acute type B aortic dissection in the International Registry of Acute Aortic Dissection. METHODS: From 1996 - 2022, 3 908 patients were divided into similar sized quartiles (T1, T2, T3, and T4). In hospital outcomes were analysed for each quartile. Survival rates following admission were compared using Kaplan-Meier analyses with Mantel-Cox Log rank tests. RESULTS: Endovascular treatment increased from 19.1% in T1 to 37.2% in T4 (ptrend < .001). Correspondingly, medical therapy decreased from 65.7% in T1 to 54.0% in T4 (ptrend < .001), and open surgery from 14.8% in T1 to 7.0% in T4 (ptrend < .001). In hospital mortality decreased in the overall cohort from 10.7% in T1 to 6.1% in T4 (ptrend < .001), as well as in medically, endovascularly and surgically treated patients (ptrend = .017, .033, and .011, respectively). Overall post-admission survival at three years increased (T1: 74.8% vs. T4: 77.3%; p = .006). CONCLUSION: Considerable changes in the management of acute type B aortic dissection were observed over time, with a significant increase in the use of endovascular treatment and a corresponding reduction in open surgery and medical management. These changes were associated with a decreased overall in hospital and three year post-admission mortality rate among quartiles.

10.
Thorac Cardiovasc Surg ; 71(5): 387-397, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-35644134

RESUMEN

BACKGROUND: The advent of transcatheter aortic valve replacement (AVR) has led to an increased emphasis on reducing the invasiveness of surgical procedures. The aim of this study was to evaluate clinical outcomes and hemodynamic performance achieved with minimally invasive aortic valve replacement (MI-AVR) as compared with conventional AVR. METHODS: Patients who underwent surgical AVR with the Avalus bioprosthesis, as part of a prospective multicenter non-randomized trial, were included in this analysis. Surgical approach was left to the discretion of the surgeons. Patient characteristics and clinical outcomes were compared between MI-AVR and conventional AVR groups in the entire cohort (n = 1077) and in an isolated AVR subcohort (n = 528). Propensity score adjustment was performed to estimate the effect of MI-AVR on adverse events. RESULTS: Patients treated with MI-AVR were younger, had lower STS scores, and underwent concomitant procedures less often. Valve size implanted was comparable between the groups. MI-AVR was associated with longer procedural times in the isolated AVR subcohort. Postprocedural hemodynamic performance was comparable. There were no significant differences between MI-AVR and conventional AVR in early and 3-year all-cause mortality, thromboembolism, reintervention, or a composite of those endpoints within either the entire cohort or the isolated AVR subcohort. After propensity score adjustment, there remained no association between MI-AVR and the composite endpoint (hazard ratio: 0.86, 95% confidence interval: 0.47-1.55, p = 0.61). CONCLUSION: Three-year outcomes after MI-AVR with the Avalus bioprosthetic valve were comparable to conventional AVR. These results provide important insights into the overall ability to reduce the invasiveness of AVR without compromising outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estudios Prospectivos , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Hemodinámica , Estudios Retrospectivos
11.
BMC Nephrol ; 24(1): 212, 2023 07 18.
Artículo en Inglés | MEDLINE | ID: mdl-37464296

RESUMEN

BACKGROUND: Kidney diseases with genetic etiology in children present with an overlapping spectrum of manifestations. We aimed to analyze the clinical utility of genetic testing in the diagnosis and management of suspected genetic kidney diseases in children. METHODS: In this retrospective study, children ≤ 18 years in whom a genetic test was ordered were included. Clinical indications for genetic testing were categorized as Glomerular diseases, nephrolithiasis and/or nephrocalcinoses, tubulopathies, cystic kidney diseases, congenital abnormality of kidney and urinary tract, chronic kidney disease of unknown aetiology and others. Clinical exome sequencing was the test of choice. Other genetic tests ordered were sanger sequencing, gene panel, multiplex ligation-dependent probe amplification and karyotyping. The pathogenicity of the genetic variant was interpreted as per the American College of Medical Genetics classification. RESULTS: A total of 86 samples were sent for genetic testing from 76 index children, 8 parents and 2 fetuses. A total of 74 variants were reported in 47 genes. Out of 74 variants, 42 were missense, 9 nonsense, 12 frameshifts, 1 indel, 5 affected the splicing regions and 5 were copy number variants. Thirty-two were homozygous, 36 heterozygous and 6 were hemizygous variants. Twenty-four children (31.6%) had pathogenic and 11 (14.5%) had likely pathogenic variants. Twenty-four children (31.6%) had variants of uncertain significance. No variants were reported in 17 children (22.3%). A genetic diagnosis was made in 35 children with an overall yield of 46%. The diagnostic yield was 29.4% for glomerular diseases, 53.8% for tubular disorders, 81% for nephrolithiasis and/or nephrocalcinoses, 60% for cystic kidney diseases and 50% for chronic kidney disease of unknown etiology. Genetic testing made a new diagnosis or changed the diagnosis in 15 children (19.7%). CONCLUSION: Nearly half (46%) of the children tested for a genetic disease had a genetic diagnosis. Genetic testing confirmed the clinical diagnoses, changed the clinical diagnoses or made a new diagnosis which helped in personalized management.


Asunto(s)
Enfermedades Renales Quísticas , Nefrocalcinosis , Nefrolitiasis , Humanos , Niño , Estudios Retrospectivos , Pruebas Genéticas , Enfermedades Renales Quísticas/diagnóstico , Enfermedades Renales Quísticas/genética
12.
Radiology ; 302(1): 218-225, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34665030

RESUMEN

Background Aortic diameter measurements in patients with a thoracic aortic aneurysm (TAA) show wide variation. There is no technique to quantify aortic growth in a three-dimensional (3D) manner. Purpose To validate a CT-based technique for quantification of 3D growth based on deformable registration in patients with TAA. Materials and Methods Patients with ascending and descending TAA with two or more CT angiography studies between 2006 and 2020 were retrospectively identified. The 3D aortic growth was quantified using vascular deformation mapping (VDM), a technique that uses deformable registration to warp a mesh constructed from baseline aortic anatomy. Growth assessments between VDM and clinical CT diameter measurements were compared. Aortic growth was quantified as the ratio of change in surface area at each mesh element (area ratio). Manual segmentations were performed by independent raters to assess interrater reproducibility. Registration error was assessed using manually placed landmarks. Agreement between VDM and clinical diameter measurements was assessed using Pearson correlation and Cohen κ coefficients. Results A total of 38 patients (68 surveillance intervals) were evaluated (mean age, 69 years ± 9 [standard deviation]; 21 women), with TAA involving the ascending aorta (n = 26), descending aorta (n = 10), or both (n = 2). VDM was technically successful in 35 of 38 (92%) patients and 58 of 68 intervals (85%). Median registration error was 0.77 mm (interquartile range, 0.54-1.10 mm). Interrater agreement was high for aortic segmentation (Dice similarity coefficient = 0.97 ± 0.02) and VDM-derived area ratio (bias = 0.0, limits of agreement: -0.03 to 0.03). There was strong agreement (r = 0.85, P < .001) between peak area ratio values and diameter change. VDM detected growth in 14 of 58 (24%) intervals. VDM revealed growth outside the maximally dilated segment in six of 14 (36%) growth intervals, none of which were detected with diameter measurements. Conclusion Vascular deformation mapping provided reliable and comprehensive quantitative assessment of three-dimensional aortic growth and growth patterns in patients with thoracic aortic aneurysms undergoing CT surveillance. Published under a CC BY 4.0 license Online supplemental material is available for this article. See also the editorial by Wieben in this issue.


Asunto(s)
Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/patología , Angiografía por Tomografía Computarizada/métodos , Imagenología Tridimensional/métodos , Anciano , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/patología , Femenino , Humanos , Masculino , Reproducibilidad de los Resultados , Estudios Retrospectivos
13.
J Vasc Surg ; 76(5): 1141-1149.e3, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35709864

RESUMEN

OBJECTIVE: Thoracic endovascular aortic repair has emerged as the dominant paradigm for treatment of patients with descending thoracic aortic aneurysms. For aneurysms involving the aortic arch in the region of the left subclavian artery (LSA), branch vessel preservation to maintain blood flow to the LSA is recommended. Branched aortic endografts are an alternative to surgical revascularization of the LSA. METHODS: Across 34 investigative sites, 84 patients with zone 2 aneurysms were enrolled in a nonrandomized, prospective study of a single branched aortic endograft. The thoracic branch endoprosthesis device allows for graft placement proximal to the LSA and incorporates a single side branch for left subclavian perfusion. RESULTS: More than one-half of the patients were male (63%). Their average age was 70 ± 11 years. The aneurysm morphology was fusiform in 43 and saccular in 41 patients. The mean aneurysm diameter at screening was 56.2 mm. The mean follow-up was 30 months (range, 2.6-50.7 months). Reported here are the patient outcomes at 1 and 12 months. Predefined technical success with implantation of the device in landing zone 2 was achieved in 92% of patients (n = 77). There were no cases of aortic rupture, lesion-related mortality, or new-onset renal failure. There was no perioperative (30-day) mortality. A single case each of permanent paraplegia and paraparesis occurred. Three patients experienced a procedure-related stroke. Through 12 months, four patients died; none of the deaths were adjudicated as related to the device or procedure. One aortic reintervention was required. A single case of aortic enlargement (core laboratory) was reported at 6 months. Type I (n = 3) and III (n = 5) endoleaks occurred in 9.8% of patients, of which one (type III) required reintervention. CONCLUSIONS: Results from this device study in patients with zone 2 aneurysms demonstrate that early safety and efficacy outcomes are maintained up to 12 months after the endovascular procedure with low mortality and reintervention rates and an acceptable frequency of procedural complications, including neurologic complications.


Asunto(s)
Aneurisma de la Aorta Torácica , Rotura de la Aorta , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Masculino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Femenino , Arteria Subclavia/diagnóstico por imagen , Arteria Subclavia/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/etiología , Prótesis Vascular , Estudios Prospectivos , Resultado del Tratamiento , Aorta Torácica/cirugía , Rotura de la Aorta/cirugía , Estudios Retrospectivos
14.
Eur J Vasc Endovasc Surg ; 64(6): 639-645, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35970335

RESUMEN

OBJECTIVE: Aortic aneurysms involving aortic arch vessels are anatomically unsuitable for standard thoracic endovascular repair (TEVAR) without cervical debranching of the arch vessels. Three year outcomes of a single branched thoracic endograft following previous publication of peri-operative and one year outcomes are reported. METHODS: This was a multicentre feasibility trial of the GORE TAG Thoracic Branch Endoprosthesis (TBE), a thoracic endovascular graft incorporating a single retrograde branch for aortic arch vessel perfusion. The first study arm enrolled patients with an intact descending thoracic aortic aneurysm extending to the distal arch with left subclavian artery (LSA) incorporation (zone 2). The second arm enrolled patients with arch aneurysms requiring incorporation of the left carotid or innominate artery (zone 0/1) and extra-anatomic surgical revascularisation of the remaining aortic arch vessels. Outcomes at three years are reported. RESULTS: The cohort comprised 40 patients (31 zone 2, nine zone 0/1). The majority were male (52%). Mean follow up was 1 408 ± 552 days in the zone 2 and 1 187 ± 766 days in the zone 0/1 cohort. During three year follow up there was no device migration, fracture, or aortic rupture in either arm. In the zone 2 arm, freedom from re-intervention was 97% at one and three years but there were two side branch occlusions. Two patients had aneurysm enlargement > 5 mm without documented endoleak or re-intervention. Freedom from death at one and three years was 90% and 84%. In the zone 0/1 arm there were no re-interventions, loss of branch patency, or aneurysm enlargement at three years. Cerebrovascular events occurred in three patients during follow up: two unrelated to the device or procedure, and one of unknown relationship. Two patients in this arm died during the follow up period, both unrelated to the procedure or the aneurysm. CONCLUSION: Initial three year results of the TBE device for endovascular repair of arch aneurysms show favourable patency and durability with low rates of graft related complications.


Asunto(s)
Aneurisma del Arco Aórtico , Aneurisma de la Aorta Torácica , Aneurisma de la Aorta , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Femenino , Humanos , Masculino , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Aneurisma de la Aorta/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Prótesis Vascular , Complicaciones Posoperatorias/cirugía , Diseño de Prótesis , Estudios Retrospectivos , Stents , Resultado del Tratamiento , Estudios de Factibilidad
15.
Nephrology (Carlton) ; 27(2): 195-207, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34378832

RESUMEN

BACKGROUND: There is a scarcity of data comparing the consequences of first and second COVID-19 waves on kidney transplant recipients (KTRs) in India. METHODS: We conducted a single-centre retrospective study of 259 KTRs with COVID-19 to compare first wave (March 15-December 31 2020, n = 157) and second wave (April 1-May 31 2021, n = 102). RESULTS: KTRs during second wave were younger (43 vs. 40 years; p-value .04) and also included paediatric patients (0 vs. 5.9%; p-value .003). Symptoms were milder during the second wave (45 vs. 62.7%; p-value .007); COVID-19 positive patients had less frequent cough (32 vs. 13.8%; p-value .001), fever was less frequent (58 vs. 37%; p-value .001), and we observed fewer co-morbidities (11 vs. 20.6%; p-value .04). The percentages of neutrophils (77 vs. 83%; p-value .001) and serum ferritin (439 vs. 688; p-value .0006) were higher during second wave, while lymphocyte counts were reduced (20 vs. 14%; p-value .0001). Hydroxychloroquine (11 vs. 0%; p-value .0001) and tocilizumab (7 vs. 0%; p-value .004) were more frequently prescribed during first wave, while utilization of dexamethasone (6 vs. 27%; p-value .0001) and remdesivir (47 vs. 65%; p-value .03) increased during the second wave. Mucormycosis (1.3 vs. 10%; p-value .01) and ICU admissions (20 vs. 37.2%; p-value .002) were more frequent during second wave. The 28-day mortality rate (9.6 vs. 10%; p-value 1) was not different. CONCLUSIONS: There has been a different clinical spectrum of COVID-19 amongst KTR with similar mortality between the two waves at a large Indian transplant centre.


Asunto(s)
COVID-19 , Fallo Renal Crónico , Trasplante de Riñón , Receptores de Trasplantes/estadística & datos numéricos , Adulto , Factores de Edad , Antivirales/administración & dosificación , Antivirales/clasificación , COVID-19/sangre , COVID-19/diagnóstico , COVID-19/epidemiología , COVID-19/terapia , Comorbilidad , Femenino , Humanos , Terapia de Inmunosupresión/métodos , Terapia de Inmunosupresión/estadística & datos numéricos , India/epidemiología , Unidades de Cuidados Intensivos/estadística & datos numéricos , Fallo Renal Crónico/epidemiología , Fallo Renal Crónico/cirugía , Trasplante de Riñón/métodos , Trasplante de Riñón/estadística & datos numéricos , Masculino , Mortalidad , Periodo Posoperatorio , Estudios Retrospectivos , SARS-CoV-2 , Evaluación de Síntomas/métodos , Evaluación de Síntomas/estadística & datos numéricos
16.
J Card Surg ; 37(6): 1674-1681, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35262974

RESUMEN

BACKGROUND: To determine the progression of aortic root in acute type A aortic dissection (ATAAD) patients after aortic root repair (ARr) or replacement (ARR) based on long-term follow-up imaging studies. METHODS: From 1996 to 2019, 732 patients had ATAAD repair at our institution. Six hundred and seven of these patients had either ARr, (n = 383) or ARR (n = 224). Eighty-one patients were excluded due to a lack of postoperative imaging. Three hundred and thirty-two patients were included in the repair group and 194 patients in the replacement group for long-term follow-up imaging study. RESULTS: Compared to the ARR group, the ARr group was significantly older (60 years vs. 55 years) and had more patients with hypertension (79% vs. 63%) but less male patients (63% vs. 79%) and connective tissue disorder (1.8% vs 8%). The ARr group had more zone two arch replacement (22% vs. 11%), similar HCA time (35 min vs. 31 min), shorter cardiopulmonary bypass time (203 min vs. 266 min), aortic cross-clamp time (128 min vs. 214 min), and fewer concomitant coronary artery bypass (3.9% vs. 8.9%). The root growth rate over 12 years was similar between the repair and replacement group (0.20 mm/year vs. 0.18 mm/year, p = .75). Both the repair and replacement group had similar 15-year cumulative incidence of reoperation (6.9% vs. 5.9%; p = .67), operative mortality (7.8% vs. 8.5%; p = .78), and 15-year survival (51% vs. 52%; p = .40). CONCLUSIONS: There was minimal growth of the aortic root after root repair or replacement for ATAAD patients. Both aortic root repair and replacement were acceptable techniques for ATAAD surgery in select patients.


Asunto(s)
Disección Aórtica , Implantación de Prótesis Vascular , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Aorta/diagnóstico por imagen , Aorta/cirugía , Implantación de Prótesis Vascular/métodos , Humanos , Masculino , Reoperación , Estudios Retrospectivos , Resultado del Tratamiento
17.
J Card Surg ; 37(12): 4351-4358, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36321695

RESUMEN

BACKGROUND: To compare perioperative and midterm outcomes in thoracic and thoraco-abdominal aortic aneurysm (TAA and TAAA) repair using hypothermic circulatory arrest (HCA) or aortic clamping (AC) with mild hypothermia. METHODS: From 2012 to 2021 there were 180 open repairs of a TAA or TAAA, of which 90 (50%) were done with HCA and 90 (50%) with aortic clamping with mild hypothermia. The indications for HCA were arch aneurysm, TAA from chronic aortic dissection, and inability to clamp the aorta for proximal anastomosis. RESULTS: Compared to AC, the HCA group had less prior descending aorta replacement/repair (9.1% vs. 32%, p = 0.0001). Intraoperatively, the HCA group had more TAAs (70% vs. 20%, p < 0.0001) while the AC group had more TAAAs (80% vs. 30%, p < 0.0001). HCA group had longer cardiopulmonary bypass times (242 vs. 181 min, p < 0.0001) but shorter cross-clamp time (39 vs. 120 min, p < 0.0001) and lower temperatures (18°C vs. 34°C, p < 0.0001). Postoperatively, the HCA group had longer intubation times (31 vs. 26 h, p = 0.002), but all other postoperative outcomes including paralysis (2.2% vs. 8.9%, p = 0.08), and operative mortality (4.4% vs. 2.2%, p = 0.68) were similar between HCA and AC groups. Patient age was an independent risk factor for postoperative paralysis (OR 1.07, p = 0.03) while HCA was not significant (OR 0.37, p = 0.21). Five-year survival was similar between HCA and AC groups (85% vs. 80%, p = 0.36). CONCLUSIONS: Postoperative outcomes and midterm survival were acceptable in thoracic and thoracoabdominal aneurysm patients after HCA or AC. Both HCA and AC with mild hypothermia were valid approaches in TAA/A repair.


Asunto(s)
Aneurisma de la Aorta Torácica , Aneurisma de la Aorta Toracoabdominal , Hipotermia , Humanos , Aneurisma de la Aorta Torácica/complicaciones , Constricción , Hipotermia/complicaciones , Aorta , Parálisis , Resultado del Tratamiento , Complicaciones Posoperatorias/etiología , Aorta Torácica/cirugía
18.
J Vasc Surg ; 74(5): 1483-1490.e2, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-33940079

RESUMEN

BACKGROUND: Thoracic endovascular aortic repair has radically transformed the treatment of descending thoracic aortic aneurysms. However, when aneurysms involve the aortic arch in the region of the left subclavian artery, branch vessel preservation must be considered. Branched aortic endografts have provided a new option to maintain branch patency. METHODS: Six investigative sites enrolled 31 patients in a nonrandomized, prospective investigational device exemption feasibility trial of a single branched aortic endograft for the management of aneurysms that include the distal aortic arch. The Gore TAG thoracic branch endoprosthesis (W. L. Gore & Associates, Inc, Flagstaff, Ariz), an investigational device, allows for graft placement proximal to the left subclavian artery and incorporates a single side branch for left subclavian perfusion. RESULTS: All 31 patients (100%) had undergone successful implantation of the investigational device in landing zone 2. Men slightly outnumbered women (51.6%). Their average age was 74.1 ± 10.4 years. The aneurysm morphology was fusiform in 12 and saccular in 19 patients, with a mean maximum aortic diameter of 54.8 ± 10.9 mm. The mean follow-up period for the cohort was 25.2 ± 11.1 months. We have reported the patient outcomes at 1 month and 1 year. At 1 month, the side branch patency was 100% and the freedom from core laboratory-reported device-related endoleak (types I and III) was 96.7%, without 30-day death or permanent paraplegia. One patient experienced a procedure-related stroke. Through 1 year, five patients had died; none of the deaths were related to the device or procedure (clinical endpoint committee adjudicated). One thoracic reintervention was required. No conversions were required, and no aneurysm growth (core laboratory) was reported. One case of the loss of side branch patency was diagnosed in the left subclavian artery in an asymptomatic individual from computed tomography at 6 months, with no reported subsequent adverse events due to loss of patency. Endoleaks were reported by the core laboratory in five patients at 12 months (two, type II; and three, indeterminate). CONCLUSIONS: The present investigational device exemption feasibility study has reported the preliminary results of the use of a single side branch endograft to treat patients with proximal descending thoracic aortic aneurysms.


Asunto(s)
Aneurisma de la Aorta Torácica/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Stents , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/fisiopatología , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/terapia , Estudios Prospectivos , Diseño de Prótesis , Retratamiento , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos , Grado de Desobstrucción Vascular
19.
Clin Transplant ; 35(7): e14332, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33914386

RESUMEN

INTRODUCTION: The literature on dengue infection in renal transplant recipients has shown wide diversity in clinical presentation and outcome. The objective of this study was to report the clinical profile, short-term and long-term outcomes of dengue among renal transplant recipients. METHODS: A total of 59 post-transplant dengue suspected cases were admitted from July 2019 to April 2020 of which 31 had confirmed dengue infection. The clinical and laboratory profile of the confirmed dengue cases (n = 31) were compared with non-dengue cases (n = 28). RESULTS: Among the clinical and laboratory features retro-orbital pain, conjunctival redness, thrombocytopenia on admission, and absence of arthralgia were significantly associated with dengue compared to non-dengue cases. No mortality was observed in the dengue cases. Allograft dysfunction, acute rejection and graft losses were identified in 64.5% (n = 20), 6.4% (n = 2) and 6.4% (n = 2) dengue cases respectively. No rejection or graft losses were observed in 1-year follow-up. CONCLUSIONS: We report a differential clinical profile for dengue in transplant settings which will aid in the diagnosis. We also report successful management of dengue infection in renal transplant recipients with the majority having allograft dysfunction. A long-term follow-up of the cohort was uneventful.


Asunto(s)
Dengue , Trasplante de Riñón , Dengue/diagnóstico , Rechazo de Injerto/etiología , Humanos , Riñón , Trasplante de Riñón/efectos adversos , Estudios Retrospectivos , Receptores de Trasplantes
20.
J Cardiovasc Magn Reson ; 23(1): 51, 2021 05 13.
Artículo en Inglés | MEDLINE | ID: mdl-33980249

RESUMEN

BACKGROUND: Chronic type B aortic dissection (TBAD) is associated with poor long-term outcome, and accurate risk stratification tools remain lacking. Pressurization of the false lumen (FL) has been recognized as central in promoting aortic growth. Several surrogate imaging-based metrics have been proposed to assess FL hemodynamics; however, their relationship to enlarging aortic dimensions remains unclear. We investigated the association between aortic growth and three cardiovascular magnetic resonance (CMR)-derived metrics of FL pressurization: false lumen ejection fraction (FLEF), maximum systolic deceleration rate (MSDR), and FL relative pressure (FL ΔPmax). METHODS: CMR/CMR angiography was performed in 12 patients with chronic dissection of the descending thoracoabdominal aorta, including contrast-enhanced CMR angiography and time-resolved three-dimensional phase-contrast CMR (4D Flow CMR). Aortic growth rate was calculated as the change in maximal aortic diameter between baseline and follow-up imaging studies over the time interval, with patients categorized as having either 'stable' (< 3 mm/year) or 'enlarging' (≥ 3 mm/year) growth. Three metrics relating to FL pressurization were defined as: (1) FLEF: the ratio between retrograde and antegrade flow at the TBAD entry tear, (2) MSDR: the absolute difference between maximum and minimum systolic acceleration in the proximal FL, and (3) FL ΔPmax: the difference in absolute pressure between aortic root and distal FL. RESULTS: FLEF was higher in enlarging TBAD (49.0 ± 17.9% vs. 10.0 ± 11.9%, p = 0.002), whereas FL ΔPmax was lower (32.2 ± 10.8 vs. 57.2 ± 12.5 mmHg/m, p = 0.017). MSDR and conventional anatomic variables did not differ significantly between groups. FLEF showed positive (r = 0.78, p = 0.003) correlation with aortic growth rate whereas FL ΔPmax showed negative correlation (r = - 0.64, p = 0.026). FLEF and FL ΔPmax remained as independent predictors of aortic growth rate after adjusting for baseline aortic diameter. CONCLUSION: Comparative analysis of three 4D flow CMR metrics of TBAD FL pressurization demonstrated that those that focusing on retrograde flow (FLEF) and relative pressure (FL ΔPmax) independently correlated with growth and differentiated patients with enlarging and stable descending aortic dissections. These results emphasize the highly variable nature of aortic hemodynamics in TBAD patients, and suggest that 4D Flow CMR derived metrics of FL pressurization may be useful to separate patients at highest and lowest risk for progressive aortic growth and complications.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Disección Aórtica/diagnóstico por imagen , Aorta , Hemodinámica , Humanos , Espectroscopía de Resonancia Magnética , Valor Predictivo de las Pruebas , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA