1.
J Cardiovasc Electrophysiol ; 35(2): 301-306, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38100289

RESUMEN

BACKGROUND: Pacemaker-induced cardiomyopathy is a well described phenomenon in patients with preserved ejection fraction at the time of permanent pacemaker implant. One of the identified risk factors for pacemaker-induced cardiomyopathy is the degree of ventricular pacing burden. However, it is unclear how a high right ventricular pacing burden affects patients with depressed left ventricular function at the time of pacemaker implantation. We sought to assess the relationship between right ventricular pacing and change in left ventricular function over time. METHODS: We conducted an analysis of all patients who had received either a single or dual lead cardiac implantable electronic devices, excluding biventricular devices, and had a prior transthoracic echocardiogram demonstrating an ejection fraction of less than 50%. The primary end-point was the correlation between the percentage of ventricular pacing and the change in LV ejection fraction. RESULTS: Fifty eight patients with preceding heart failure had pacemakers implanted and had follow up echocardiograms. There was no correlation between the degree of ventricular pacing and the absolute change in LV function (r = .04, p = .979). None of the previously identified risk factors for pacemaker induced cardiomyopathy were predictive of a significant fall in ejection fraction. CONCLUSION: The degree of RV pacing and other established risk factors for pacemaker-induced cardiomyopathy in patients with normal left ventricular function at the time of implantation do not appear to carry the same risk in patients with pre-existing heart failure who receive either single or dual lead pacemakers.


Asunto(s)
Cardiomiopatías , Insuficiencia Cardíaca , Marcapaso Artificial , Disfunción Ventricular Izquierda , Humanos , Función Ventricular Izquierda , Volumen Sistólico , Marcapaso Artificial/efectos adversos , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/etiología , Disfunción Ventricular Izquierda/terapia , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/complicaciones , Estimulación Cardíaca Artificial/efectos adversos , Resultado del Tratamiento
2.
JAMA ; 329(2): 127-135, 2023 01 10.
Artículo en Inglés | MEDLINE | ID: mdl-36625809

RESUMEN

Importance: Pulmonary vein isolation (PVI) alone is less effective in patients with persistent atrial fibrillation (AF) compared with paroxysmal AF. The left atrial posterior wall may contribute to maintenance of persistent AF, and posterior wall isolation (PWI) is a common PVI adjunct. However, PWI has not been subjected to randomized comparison. Objective: To compare PVI with PWI vs PVI alone in patients with persistent AF undergoing first-time catheter ablation. Design, Setting, and Participants: Investigator initiated, multicenter, randomized clinical trial involving 11 centers in 3 countries (Australia, Canada, UK). Symptomatic patients with persistent AF were randomized 1:1 to either PVI with PWI or PVI alone. Patients were enrolled July 2018-March 2021, with 1-year follow-up completed March 2022. Interventions: The PVI with PWI group (n = 170) underwent wide antral pulmonary vein isolation followed by posterior wall isolation involving linear ablation at the roof and floor to achieve electrical isolation. The PVI-alone group (n = 168) underwent wide antral pulmonary vein isolation alone. Main Outcomes and Measures: Primary end point was freedom from any documented atrial arrhythmia of more than 30 seconds without antiarrhythmic medication at 12 months, after a single ablation procedure. The 23 secondary outcomes included freedom from atrial arrhythmia with/without antiarrhythmic medication after multiple procedures, freedom from symptomatic AF with/without antiarrhythmic medication after multiple procedures, AF burden between study groups at 12 months, procedural outcomes, and complications. Results: Among 338 patients randomized (median age, 65.6 [IQR, 13.1] years; 76.9% men), 330 (97.6%) completed the study. After 12 months, 89 patients (52.4%) assigned to PVI with PWI were free from recurrent atrial arrhythmia without antiarrhythmic medication after a single procedure, compared with 90 (53.6%) assigned to PVI alone (between-group difference, -1.2%; hazard ratio [HR], 0.99 [95% CI, 0.73-1.36]; P = .98). Of the secondary end points, 9 showed no significant difference, including freedom from atrial arrhythmia with/without antiarrhythmic medication after multiple procedures (58.2% for PVI with PWI vs 60.1% for PVI alone; HR, 1.10 [95% CI, 0.79-1.55]; P = .57), freedom from symptomatic AF with/without antiarrhythmic medication after multiple procedures (68.2% vs 72%; HR, 1.20 [95% CI, 0.80-1.78]; P = .36) or AF burden (0% [IQR, 0%-2.3%] vs 0% [IQR, 0%-2.8%], P = .47). Mean procedural times (142 [SD, 69] vs 121 [SD, 57] minutes, P < .001) and ablation times (34 [SD, 21] vs 28 [SD, 12] minutes, P < .001) were significantly shorter for PVI alone. There were 6 complications for PVI with PWI and 4 for PVI alone. Conclusions and Relevance: In patients undergoing first-time catheter ablation for persistent AF, the addition of PWI to PVI alone did not significantly improve freedom from atrial arrhythmia at 12 months compared with PVI alone. These findings do not support the empirical inclusion of PWI for ablation of persistent AF. Trial Registration: anzctr.org.au Identifier: ACTRN12616001436460.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Anciano , Femenino , Humanos , Masculino , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/etiología , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Atrios Cardíacos/cirugía , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento , Persona de Mediana Edad , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Procedimientos Quirúrgicos Cardíacos/métodos
3.
Am Heart J ; 243: 210-220, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34619143

RESUMEN

BACKGROUND: The success of pulmonary vein isolation (PVI) is reduced in persistent AF (PsAF) compared to paroxysmal AF. Adjunctive ablation strategies have failed to show consistent incremental benefit over PVI alone in randomized studies. The left atrial posterior wall is a potential source of non-PV triggers and atrial substrate which may promote the initiation and maintenance of PsAF. Adding posterior wall isolation (PWI) to PVI had shown conflicting outcomes, with earlier studies confounded by methodological limitations. OBJECTIVES: To determine whether combining PWI with PVI significantly improves freedom from AF recurrence, compared to PVI alone, in patients with PsAF. METHODS: This is a multi-center, prospective, international randomized clinical trial. 338 patients with symptomatic PsAF refractory to anti-arrhythmic therapy (AAD) will be randomized to either PVI alone or PVI with PWI in a 1:1 ratio. PVI involves wide antral circumferential pulmonary vein (PV) isolation, utilizing contact force sensing ablation catheters. PWI involves the creation of a floor line connecting the inferior aspect of the PVs, and a roof line connecting the superior aspect of the PVs. Follow up is for a minimum of 12 months with rhythm monitoring via implantable cardiac device and/or loop monitor, or frequent intermittent monitoring with an ECG device. The primary outcome is freedom from any documented atrial arrhythmia of > 30 seconds off AAD at 12 months, after a single ablation procedure. CONCLUSIONS: This randomized study aims to determine the success and safety of adjunctive PWI to PVI in patients with persistent AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Humanos , Estudios Prospectivos , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
5.
J Cardiovasc Electrophysiol ; 28(10): 1109-1116, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28730651

RESUMEN

INTRODUCTION: The right atrium (RA) is readily accessible; however, it is unclear whether changes in the RA are representative of the LA. We performed detailed biatrial electroanatomic mapping to determine the electrophysiological relationship between the atria. METHODS AND RESULTS: Consecutive patients with persistent AF underwent biatrial electroanatomical mapping with a contact force catheter acquiring points with a CF >10 g prior to ablation. Points were analyzed for tissue voltage, complex electrograms, low voltage (<0.5 mV), scar (<0.05 mV), and conduction velocity (CV). Forty patients (mean age 59 ± 9.2 years, AF duration 12.9 ± 9.2 months, LA area: 28 ± 5.2, RA area: 25 ± 6.4 mm2 , LVEF: 44 ± 15%) underwent mapping during CS pacing. Bipolar voltage (R = 0.57, P <0.001), unipolar voltage (R = 0.68, P <0.001), low voltage (<0.5 nV) (R = 0.48, P = 0.002), fractionation (R = 0.73, P <0.001), and CV (R = 0.49, P = 0.001) correlated well between atria. There was no difference in global bipolar voltage (LA 1.89 ± 0.77 vs. RA 1.77 ± 0.57 mV, P = 0.57); complex electrograms (LA 20% vs. RA 20%, P = 0.99) or low voltage (LA 15% vs. RA 16%, P = 0.84). Global unipolar voltage was significantly higher in the LA compared to the RA (2.95 ± 1.14 vs. 2.28 ± 0.65 mV, P = 0.002) and CV was significantly slower in the RA compared to the LA (0.93 ± 0.15 m/s vs. 1.01 ± 0.19 m/s, P = 0.001). CONCLUSION: AF is associated with remodeling processes affecting both atria. The more accessible RA provides an insight into the biatrial process associated with AF in various disease states without trans-septal access.


Asunto(s)
Fibrilación Atrial/fisiopatología , Técnicas Electrofisiológicas Cardíacas/métodos , Atrios Cardíacos/fisiopatología , Anciano , Fibrilación Atrial/terapia , Remodelación Atrial , Mapeo del Potencial de Superficie Corporal , Cateterismo Cardíaco , Electrofisiología Cardíaca , Ablación por Catéter , Electrocardiografía , Femenino , Sistema de Conducción Cardíaco/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
6.
Europace ; 19(12): 1958-1966, 2017 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-28204434

RESUMEN

AIMS: Catheter ablation to achieve posterior left atrial wall (PW) isolation may be performed as an adjunct to pulmonary vein isolation (PVI) in patients with persistent atrial fibrillation (AF). We aimed to determine whether routine adenosine challenge for dormant posterior wall conduction improved long-term outcome. METHODS AND RESULTS: A total of 161 patients with persistent AF (mean age 59 ± 9 years, AF duration 6 ± 5 years) underwent catheter ablation involving circumferential PVI followed by PW isolation. Posterior left atrial wall isolation was performed with a roof and inferior wall line with the endpoint of bidirectional block. In 54 patients, adenosine 15 mg was sequentially administered to assess reconnection of the pulmonary veins and PW. Sites of transient reconnection were ablated and adenosine was repeated until no further reconnection was present. Holter monitoring was performed at 6 and 12 months to assess for arrhythmia recurrence. Posterior left atrial wall isolation was successfully achieved in 91% of 161 patients (procedure duration 191 ± 49 min, mean RF time 40 ± 19 min). Adenosine-induced reconnection of the PW was demonstrated in 17%. The single procedure freedom from recurrent atrial arrhythmia was superior in the adenosine challenge group (65%) vs. no adenosine challenge (40%, P < 0.01) at a mean follow-up of 19 ± 8 months. After multiple procedures, there was significantly improved freedom from AF between patients with vs. without adenosine PW challenge (85 vs. 65%, P = 0.01). CONCLUSION: Posterior left atrial wall isolation in addition to PVI is a readily achievable ablation strategy in patients with persistent AF. Routine adenosine challenge for dormant posterior wall conduction was associated with an improvement in the success of catheter ablation for persistent AF.


Asunto(s)
Adenosina/administración & dosificación , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Función del Atrio Izquierdo , Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas , Atrios Cardíacos/cirugía , Venas Pulmonares/cirugía , Potenciales de Acción , Anciano , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Supervivencia sin Enfermedad , Electrocardiografía Ambulatoria , Femenino , Atrios Cardíacos/fisiopatología , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Venas Pulmonares/fisiopatología , Recurrencia , Factores de Tiempo , Resultado del Tratamiento
7.
Heart Lung Circ ; 24(4): 354-8, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25488381

RESUMEN

BACKGROUND: Recent pacing guidelines from the European Society of Cardiology recommend cardiac resynchronisation therapy (CRT) in patients with an atrioventricular (AV) nodal pacing indication and reduced ejection fraction (EF). However, concerns over added expenditure may limit its widespread implementation. We investigate the potential incremental cost of biventricular over right ventricular pacing if such a practice was adopted. METHODS: Retrospective analysis was performed of devices implanted over eight years. The database was analysed for device type, pacing indication and EF. Cost analysis was performed. RESULTS: 1751 devices were implanted over eight years at an averaged cost of AUD$1,369,125 per year. 172 with CRT were excluded. 25.4 (11.6%) patients per year had an EF≤50% and AV nodal disease. 18.4 were in sinus rhythm (SR) and 7.0 in atrial fibrillation (AF). Of these, 13.5 (6.2%) had EF≤45% (9.9 SR, 3.6 AF) and 8.2 (3.8%) had EF≤35% (5.6 SR, 2.6 AF). Based on an incremental cost of $4,000 per device, if all patients with EF≤50% received CRT, the total cost increment per year equates to $73,500 for SR patients or $101,500 if AF patients were included. In patients with EF≤35% and EF≤45%, this amounts to $22,500 and $39,500 per year for SR patients respectively or $33,000 and $54,000 per year if AF patients were included. Depending on the EF and rhythm, this represents a 1.6% to 7.4% increase per year in the pacing budget for an increased patient population of between 2.6% (EF≤35% in SR) to 11.6% (EF≤50%). CONCLUSION: A small proportion of additional patients will qualify for CRT based on the chosen cut-off and rhythm. Although the individual incremental cost for biventricular over right ventricular pacing is high in patients with AV nodal disease and reduced EF, overall this represents at most, a modest increase in the total pacing budget.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca/economía , Terapia de Resincronización Cardíaca/economía , Bases de Datos Factuales , Volumen Sistólico , Taquicardia por Reentrada en el Nodo Atrioventricular/economía , Terapia de Resincronización Cardíaca/métodos , Costos y Análisis de Costo , Femenino , Humanos , Masculino , Taquicardia por Reentrada en el Nodo Atrioventricular/terapia
8.
JACC Clin Electrophysiol ; 10(2): 206-218, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38099880

RESUMEN

BACKGROUND: Accurate annotation of electrogram local activation time (LAT) is critical to the functional assessment of ventricular tachycardia (VT) substrate. Contemporary methods of annotation include: 1) earliest bipolar electrogram (LATearliest); 2) peak bipolar electrogram (LATpeak); 3) latest bipolar electrogram (LATlatest); and 4) steepest unipolar -dV/dt (LAT-dV/dt). However, no direct comparison of these methods has been performed in a large dataset, and it is unclear which provides the optimal functional analysis of the VT substrate. OBJECTIVES: This study sought to investigate the optimal method of LAT annotation during VT substrate mapping. METHODS: Patients with high-density VT substrate maps and a defined critical site for VT re-entry were included. All electrograms were annotated using 5 different methods: LATearliest, LATpeak, LATlatest, LAT-dV/dt, and the novel steepest unipolar -dV/dt using a dynamic window of interest (LATDWOI). Electrograms were also tagged as either late potentials and/or fractionated signals. Maps, utilizing each annotation method, were then compared in their ability to identify critical sites using deceleration zones. RESULTS: Fifty cases were identified with 1,.813 ± 811 points per map. Using LATlatest, a deceleration zone was present at the critical site in 100% of cases. There was no significant difference with LATearliest (100%) or LATpeak (100%). However, this number decreased to 54% using LAT-dV/dt and 76% for LATDWOI. Using LAT-dV/dt, only 33% of late potentials were correctly annotated, with the larger far field signals often annotated preferentially. CONCLUSIONS: Annotation with LAT-dV/dt and LATDWOI are suboptimal in VT substrate mapping. We propose that LATlatest should be the gold standard annotation method, as this allows identification of critical sites and is most suited to automation.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Humanos , Ablación por Catéter/métodos , Taquicardia Ventricular/cirugía , Arritmias Cardíacas , Electrocardiografía/métodos
9.
JACC Clin Electrophysiol ; 9(1): 1-16, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36697187

RESUMEN

BACKGROUND: Accurate annotation of local activation time is crucial in the functional assessment of ventricular tachycardia (VT) substrate. A major limitation of modern mapping systems is the standard prospective window of interest (sWOI) is limited to 490 to 500 milliseconds, preventing annotation of very late potentials (LPs). A novel retrospective window of interest (rWOI), which allows annotation of all diastolic potentials, was used to assess the functional VT substrate. OBJECTIVES: This study sought to investigate the utility of a novel rWOI, which allows accurate visualization and annotation of all LPs during VT substrate mapping. METHODS: Patients with high-density VT substrate maps and a defined isthmus were included. All electrograms were manually annotated to latest activation using a novel rWOI. Reannotated substrate maps were correlated to critical sites, with areas of late activation examined. Propagation patterns were examined to assess the functional aspects of the VT substrate. RESULTS: Forty-eight cases were identified with 1,820 ± 826 points per map. Using the novel rWOI, 31 maps (65%) demonstrated LPs beyond the sWOI limit. Two distinct patterns of channel activation were seen during substrate mapping: 1) functional block with unidirectional conduction into the channel (76%); and 2) wave front collision within the channel (24%). In addition, a novel marker termed the zone of early and late crowding was studied in the rWOI substrate maps and found to have a higher positive predictive value (85%) than traditional deceleration zones (69%) for detecting critical sites of re-entry. CONCLUSIONS: The standard WOI of contemporary mapping systems is arbitrarily limited and results in important very late potentials being excluded from annotation. Future versions of electroanatomical mapping systems should provide longer WOIs for accurate local activation time annotation.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Humanos , Ventrículos Cardíacos , Estudios Retrospectivos , Estudios Prospectivos , Lipopolisacáridos , Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Taquicardia Ventricular/cirugía , Arritmias Cardíacas
10.
JACC Clin Electrophysiol ; 9(7 Pt 1): 907-922, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36752465

RESUMEN

BACKGROUND: Understanding underlying mechanism(s) and identifying critical circuit components are fundamental to successful ventricular tachycardia (VT) ablation. Directed graph mapping (DGM) offers a novel technique to identify the mechanism and critical components of a VT circuit. OBJECTIVES: This study sought to evaluate the accuracy of DGM in VT ablation compared with traditional mapping techniques and a commercially available automated conduction velocity mapping (ACVM) tool. METHODS: Patients with structural heart disease who had undergone a VT ablation with entrainment-proven critical isthmus and a high-density electroanatomical activation map were included. Traditional mapping (TM) consisted of a combination of local activation time and entrainment mapping and was considered the gold standard for determining the VT mechanism, circuit, and isthmus location. The same local activation time values were then processed using DGM and a commercially available ACVM (Coherent Mapping, Biosense Webster) tool. The aim of this study was to compare TM vs DGM and ACVM in their ability to identify the VT mechanism, characterize the VT circuit, and locate the critical isthmus. RESULTS: Thirty-five cases were identified. TM classified the VT mechanism as focal in 7 patients and re-entrant in 28 patients. TM classified 11 VTs as single-loop re-entry, 15 as dual-loop re-entry, 1 as complex, and 1 case was indeterminant. The overall agreement between DGM and TM for determining VT mechanism and circuit type was strong (kappa value = 0.79; P < 0.01), as was the agreement between ACVM and TM (kappa value = 0.66; P < 0.01). Both DGM and ACVM identified the putative VT isthmus in 25 (89%) of the re-entrant cases. Focal activation was correctly identified by both techniques in all cases. CONCLUSIONS: DGM is a rapid automated algorithm that has a strong level of agreement with TM for manually re-annotated VT maps.


Asunto(s)
Ablación por Catéter , Cardiopatías , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Cardiopatías/cirugía
11.
JACC Clin Electrophysiol ; 8(6): 782-791, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35738855

RESUMEN

BACKGROUND: Smart watches and wearable technology capable of heart rhythm assessment have increased in use in the general population. The Apple Watch Series 4 (AW4) and KardiaBand (KB) are devices capable of obtaining single-lead electrocardiographic recordings, presenting a novel opportunity for the detection of paroxysmal arrhythmias. OBJECTIVES: The aim of this study was to assess the diagnostic utility of the AW4 and KB in an elderly outpatient population. METHODS: Consecutive recordings were taken from patients attending cardiology outpatient clinic from the AW4 and KB concurrently with 12-lead electrocardiography. Automated diagnoses and blinded single-lead electrocardiographic tracing interpretations by 2 cardiologists were analyzed. Analysis was also conducted to assess the effect of combined device and clinician interpretation. RESULTS: One hundred twenty-five patients were prospectively recruited (mean age 76 ± 7 years, 62% men). The accuracy of the automated rhythm assessment was higher with the KB than the AW4 (74% vs 65%). For the detection of atrial fibrillation, the sensitivity and negative predictive value of the KB were 89% and 97%, respectively, and of the AW4 were 19% and 82%, respectively. Using hybrid automated and clinician interpretation, the overall accuracy of the KB and AW4 was 91% and 87%, respectively. CONCLUSIONS: The KB automated algorithm outperformed the AW4 in its accuracy and sensitivity for detecting atrial fibrillation in the outpatient setting. Clinician assessment of the single-lead electrocardiogram improved accuracy. These findings suggest that although these devices' tracings are of sufficient quality, automated diagnosis alone is not sufficient for making clinical decisions about atrial fibrillation diagnosis and management.


Asunto(s)
Fibrilación Atrial , Dispositivos Electrónicos Vestibles , Anciano , Anciano de 80 o más Años , Algoritmos , Fibrilación Atrial/diagnóstico , Electrocardiografía , Femenino , Humanos , Masculino , Valor Predictivo de las Pruebas
12.
JACC Clin Electrophysiol ; 8(4): 480-494, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35450603

RESUMEN

OBJECTIVES: This study sought to describe the utility of automated conduction velocity mapping (ACVM) in ventricular tachycardia (VT) ablation. BACKGROUND: Identification of areas of slowed conduction velocity (CV) is critical to our understanding of VT circuits and their underlying substrate. Recently, an ACVM called Coherent Mapping (Biosense Webster Inc) has been developed for atrial mapping. However, its utility in VT mapping has not been described. METHODS: Patients with paired high-density VT activation and substrate maps were included. ACVM was applied to paired VT activation and substrate maps to assess regional CV and activation patterns. A combination of ACVM, traditional local activation time maps, electrogram analysis, and off-line calculated CV using triangulation were used to characterize zones of slowed conduction during VT and in substrate mapping. RESULTS: Fifteen patients were included in the study. In all cases, ACVM identified slow CV within the putative VT isthmus, which colocalized to the VT isthmus identified with entrainment. The dimensions of the VT isthmus with local activation time mapping were 37.8 ± 13.7 mm long and 8.7 ± 4.2 mm wide. In comparison, ACVM produced an isthmus that was shorter (length: 25.1 ± 10.6 mm; mean difference: 12.8; 95% CI: 7.5-18.0; P < 0.01) and wider (width: 18.8 ± 8.1 mm; mean difference: 10.1; 95% CI: 6.1-14.2; P < 0.01). In VT, the CV using triangulation at the entrance (8.0 ± 3.6 cm/s) and midisthmus (8.1 ± 4.3 cm/s) was not significantly different (P = 0.92) but was significantly faster at the exit (16.2 ± 9.7 cm/s; P < 0.01). In the paired substrate analysis, traditional local activation time isochronal mapping identified 6.3 ± 2.0 deceleration zones. In contrast, ACVM identified a median of 0 deceleration zones (IQR: 0-1; P < 0.01). CONCLUSIONS: ACVM is a novel complementary tool that can be used to accurately resolve complex VT circuits and identify slow conduction zones in VT but has limited accuracy in identifying slowed conduction during substrate-based mapping.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Arritmias Cardíacas , Ablación por Catéter/métodos , Sistema de Conducción Cardíaco , Frecuencia Cardíaca/fisiología , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía
13.
J Am Coll Cardiol ; 75(13): 1582-1592, 2020 04 07.
Artículo en Inglés | MEDLINE | ID: mdl-32241375

RESUMEN

Ambulatory monitoring devices are enabling a new paradigm of health care by collecting and analyzing long-term data for reliable diagnostics. These devices are becoming increasingly popular for continuous monitoring of cardiac diseases. Recent advancements have enabled solutions that are both affordable and reliable, allowing monitoring of vulnerable populations from the comfort of their homes. They provide early detection of important physiological events, leading to timely alerts for seeking medical attention. In this review, the authors aim to summarize the recent developments in the area of ambulatory and remote monitoring solutions for cardiac diagnostics. The authors cover solutions based on wearable devices, smartphones, and other ambulatory sensors. The authors also present an overview of the limitations of current technologies, their effectiveness, and their adoption in the general population, and discuss some of the recently proposed methods to overcome these challenges. Lastly, we discuss the possibilities opened by this new paradigm, for the future of health care and personalized medicine.


Asunto(s)
Monitoreo Ambulatorio de la Presión Arterial , Electrocardiografía Ambulatoria , Dispositivos Electrónicos Vestibles , Arritmias Cardíacas/diagnóstico , Capacidad Cardiovascular , Prueba de Esfuerzo , Humanos , Teléfono Inteligente , Transferencia de Tecnología
14.
JACC Clin Electrophysiol ; 6(11): 1405-1419, 2020 10 26.
Artículo en Inglés | MEDLINE | ID: mdl-33121670

RESUMEN

OBJECTIVES: This study evaluated if modifying electrocardiographic (ECG) precordial leads to a higher intercostal position improved the accuracy of outflow tract ventricular arrhythmia (OTVA) localization. BACKGROUND: Precordial ECG prediction algorithms that use a standard lead configuration localize OTVA with variable accuracy. METHODS: Patients who underwent OTVA ablation were prospectively enrolled to have a standard and modified (high) precordial ECG. R- and S-wave amplitudes and intervals were measured to develop an algorithm that differentiated the right ventricular outflow tract (RVOT) and the left ventricular outflow tract (LVOT) with high accuracy-the modified lead R-wave deflection interval (RWDI). This interval was defined from the earliest QRS onset (using all modified leads) to the lead with longest R-wave deflection. The RWDI was compared with all other ECG algorithms. RESULTS: A total of 50 patients (38 women; mean age 51 ± 17 years) had successful catheter ablation for OTVA (RVOT 60%, LVOT 40%). The modified lead RWDI was significantly shorter in the RVOT group (18.5 ms, interquartile range 25th to 75th percentile [IQR25-75]: 0 to 29.5 ms) compared with the LVOT group (67.5 ms, IQR25-75: 56.5 to 77 ms; p < 0.05). Using a RWDI ≤40 ms to predict an RVOT focus, the sensitivity and specificity of the modified lead RWDI were 100% and 95%, respectively; the area under the receiver-operating characteristic curve was 0.96. This was superior to all previously developed algorithms. In a computed tomography analysis (n = 50), the modified leads were significantly closer to the outflow tracts compared with the standard precordial leads. CONCLUSIONS: The modified lead RWDI is a simple, easily interpretable algorithm that can potentially differentiate a right- or left-sided origin of OTVA with high accuracy.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Arritmias Cardíacas/diagnóstico , Electrocardiografía , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/cirugía , Humanos , Persona de Mediana Edad , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía
16.
Heart Rhythm ; 15(2): 182-192, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-28917553

RESUMEN

BACKGROUND: Current phase mapping systems for atrial fibrillation create 2-dimensional (2D) maps. This process may affect the accurate detection of rotors. We developed a 3-dimensional (3D) phase mapping technique that uses the 3D locations of basket electrodes to project phase onto patient-specific left atrial 3D surface anatomy. OBJECTIVE: We sought to determine whether rotors detected in 2D phase maps were present at the corresponding time segments and anatomical locations in 3D phase maps. METHODS: One-minute left atrial atrial fibrillation recordings were obtained in 14 patients using the basket catheter and analyzed off-line. Using the same phase values, 2D and 3D phase maps were created. Analysis involved determining the dominant propagation patterns in 2D phase maps and evaluating the presence of rotors detected in 2D phase maps in the corresponding 3D phase maps. RESULTS: Using 2D phase mapping, the dominant propagation pattern was single wavefront (36.6%) followed by focal activation (34.0%), disorganized activity (23.7%), rotors (3.3%), and multiple wavefronts (2.4%). Ten transient rotors were observed in 9 of 14 patients (64%). The mean rotor duration was 1.1 ± 0.7 seconds. None of the 10 rotors observed in 2D phase maps were seen at the corresponding time segments and anatomical locations in 3D phase maps; 4 of 10 corresponded with single wavefronts in 3D phase maps, 2 of 10 with 2 simultaneous wavefronts, 1 of 10 with disorganized activity, and in 3 of 10 there was no coverage by the basket catheter at the corresponding 3D anatomical location. CONCLUSION: Rotors detected in 2D phase maps were not observed in the corresponding 3D phase maps. These findings may have implications for current systems that use 2D phase mapping.


Asunto(s)
Fibrilación Atrial/diagnóstico , Mapeo del Potencial de Superficie Corporal/métodos , Atrios Cardíacos/fisiopatología , Sistema de Conducción Cardíaco/fisiopatología , Imagenología Tridimensional , Fibrilación Atrial/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Factores de Tiempo
17.
JACC Clin Electrophysiol ; 4(1): 72-83, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-29600788

RESUMEN

OBJECTIVES: This study sought to validate a 3-dimensional (3D) phase mapping system and determine the distribution of dominant propagation patterns in persistent atrial fibrillation (AF). BACKGROUND: Currently available systems display phase as simplified 2-dimensional maps. We developed a novel 3D phase mapping system that uses the 3D location of basket catheter electrodes and the patient's 3D left atrial surface geometry to interpolate phase and create a 3D representation of phase progression. METHODS: Six-min AF recordings from the left atrium were obtained in 14 patients using the Constellation basket catheter and analyzed offline. Exported signals underwent both phase and traditional activation analysis and were then visualized using a novel 3D mapping system. Analysis involved: 1) validation of phase analysis by comparing beat-to-beat AF cycle length calculated using phase inversion with that determined from activation timing in the same 20-s segment; 2) validation of 3D phase by comparing propagation patterns observed using 3D phase with 3D activation in the same 1-min segment; and 3) determining the distribution of dominant propagation patterns in 6-min recordings using 3D phase. RESULTS: There was strong agreement of beat-to-beat AF cycle length between activation analysis and phase inversion (R2 = 0.91). There was no significant difference between 3D activation and 3D phase in mean percentage of propagation patterns classified as single wavefronts (p = 0.99), focal activations (p = 0.26), disorganized activity (p = 0.76), or multiple wavefronts (p = 0.70). During prolonged 3D phase, single wavefronts were the most common propagation pattern (50.2%). A total of 34 rotors were seen in 9 of 14 patients. All rotors were transient with mean duration of 1.0 ± 0.6 s. Rotors were only observed in areas of high electrode density where the interelectrode distance was significantly shorter than nonrotor sites (7.4 [interquartile range: 6.3 to 14.6] vs. 15.3 mm [interquartile range: 10.1 to 22.2]; p < 0.001). CONCLUSIONS: During prolonged 3D phase mapping, transient rotors were observed in 64% of patients and reformed at the same anatomic location in 44% of patients. The electrode density of the basket catheter may limit the detection of rotors.


Asunto(s)
Fibrilación Atrial , Electrocardiografía/métodos , Mapeo Epicárdico/métodos , Imagenología Tridimensional/métodos , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Femenino , Atrios Cardíacos/fisiopatología , Sistema de Conducción Cardíaco/fisiopatología , Humanos , Masculino , Persona de Mediana Edad
18.
JACC Clin Electrophysiol ; 4(1): 87-96, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-29600790

RESUMEN

OBJECTIVES: This study sought to characterize the biatrial substrate in heart failure (HF) and persistent atrial fibrillation (PeAF). BACKGROUND: Atrial fibrillation (AF) and HF frequently coexist; however, the contribution of HF to the biatrial substrate in PeAF is unclear. METHODS: Consecutive patients with PeAF and normal left ventricular (NLV) systolic function (left ventricular ejection fraction [LVEF] >55%) or idiopathic cardiomyopathy (LVEF ≤45%) undergoing AF ablation were enrolled. In AF, pulmonary vein (PV) cycle length (PVCL) was recorded via a multipolar catheter in each PV and in the left atrial appendage for 100 consecutive cycles. After electrical cardioversion, biatrial electroanatomic mapping was performed. Complex electrograms, voltage, scarring, and conduction velocity were assessed. RESULTS: Forty patients, 20 patients with HF (mean age: 62 ± 8.9 years; AF duration: 15 ± 11 months; LVEF: 33 ± 8.4%) and 20 with NLV (mean age: 59 ± 6.7 years; AF duration: 14 ± 9.1 months; p = 0.69; mean LVEF: 61 ± 3.6%; p < 0.001), were enrolled. HF reduced biatrial tissue voltage (p < 0.001) with greater voltage heterogeneity (p < 0.001). HF was associated with significantly more biatrial fractionation (left atrium [LA]: 30% vs. 9%; p < 0.001; right atrium [RA]: 28% vs. 11%; p < 0.001), low voltage (<0.5 mV) (LA: 23% vs. 6%; p = 0.002; RA: 20% vs 11%; p = 0.006), and scarring (<0.05 mV) in the LA (p = 0.005). HF was associated with a slower average PVCL (185 vs. 164 ms; p = 0.016), which correlated significantly with PV antral bipolar voltage (R = -0.62; p < 0.001) and fractionation (R = 0.46; p = 0.001). CONCLUSIONS: HF is associated with significantly reduced biatrial tissue voltage, fractionation, and prolongation of PVCL. Advanced biatrial remodeling may have implications for invasive and noninvasive rhythm control strategies in patients with AF and HF.


Asunto(s)
Fibrilación Atrial , Técnicas Electrofisiológicas Cardíacas/métodos , Atrios Cardíacos , Insuficiencia Cardíaca , Anciano , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/fisiopatología , Técnicas de Imagen Cardíaca , Cardiomiopatías , Femenino , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/fisiopatología , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
19.
JACC Clin Electrophysiol ; 4(8): 999-1007, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-30139501

RESUMEN

OBJECTIVES: This study sought to determine if diffuse ventricular fibrosis improves in patients with atrial fibrillation (AF)-mediated cardiomyopathy following the restoration of sinus rhythm. BACKGROUND: AF coexists in 30% of heart failure (HF) patients and may be an underrecognized reversible cause of left ventricular systolic dysfunction. Myocardial fibrosis is the hallmark of adverse cardiac remodeling in HF, yet its reversibility is unclear. METHODS: Patients with persistent AF and an idiopathic cardiomyopathy (left ventricular ejection fraction [LVEF] ≤45%) were randomized to catheter ablation (CA) or ongoing medical rate control as a pre-specified substudy of the CAMERA-MRI (Catheter Ablation versus Medical Rate Control in Atrial Fibrillation and Systolic Dysfunction-an MRI-Guided Multi-centre Randomised Controlled Trial) trial. All patients had cardiac magnetic resonance imaging scans (including myocardial T1 time), serum B-type natriuretic peptide, 6-min walk tests, and Short Form-36 questionnaires performed at baseline and 6 months. Sixteen patients with no history of AF or left ventricular systolic dysfunction were enrolled as normal controls for T1 time. RESULTS: Thirty-six patients (18 in each treatment arm) were included in this substudy. Demographics, comorbidities, and myocardial T1 times were well matched at baseline. At 6 months, patients in the CA group had a significant reduction in myocardial T1 time from baseline compared with the medical rate control group (-124 ms; 95% confidence interval [CI]: -23 to -225 ms; p = 0.0176), although it remained higher than that of normal controls at 6 months (p = 0.0017). Improvements in myocardial T1 time with CA were associated with significant improvements in absolute LVEF (+12.5%; 95% CI: 5.9% to 19.0%; p = 0.0004), left ventricular end-systolic volume (p = 0.0019), and serum B-type natriuretic peptide (-216 ng/l; 95% CI: -23 to -225 ng/l; p = 0.0125). CONCLUSIONS: The improvement in LVEF and reverse ventricular remodeling following successful CA of AF-mediated cardiomyopathy is accompanied by a regression of diffuse fibrosis. This suggests timely treatment of arrhythmia-mediated cardiomyopathy may minimize irreversible ventricular remodeling.


Asunto(s)
Fibrilación Atrial , Cardiomiopatías , Ablación por Catéter , Disfunción Ventricular Izquierda , Anciano , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Cardiomiopatías/complicaciones , Cardiomiopatías/fisiopatología , Fibrosis , Humanos , Imagen por Resonancia Magnética , Persona de Mediana Edad , Disfunción Ventricular Izquierda/complicaciones , Disfunción Ventricular Izquierda/fisiopatología
20.
Heart Rhythm ; 14(8): 1200-1207, 2017 08.
Artículo en Inglés | MEDLINE | ID: mdl-28479513

RESUMEN

BACKGROUND: Evidence for epicardial-endocardial breakthrough (EEB) is derived from mapping inferences in patients with atrial fibrillation who may also have focal activations. OBJECTIVE: The purpose of this study was to investigate whether EEB could be discerned during stable right atrial (RA) macroreentry using high-density high-spatial resolution 3-dimensional mapping. METHODS: Macroreentry was diagnosed using 3-dimensional mapping and entrainment. Bipolar maps were reviewed for EEB defined as (1) presence of focal endocardial activation with radial spread unaccounted for by an endocardial wavefront and (2) present with the same timing on every tachycardia cycle. The EEB site was always in proximity to a line of endocardial conduction slowing or block. Distance and conduction velocity from the line of block to the EEB site was calculated. Electrograms at EEB sites were individually analyzed for morphology and to confirm direction of activation. Entrainment was performed at EEB sites. RESULTS: Twenty-six patients were studied. Fourteen examples of EEB were seen: 11 at the posterior RA (4 at the superior portion of the posterior wall and 7 at the inferior section) and 1 each at the cavotricuspid isthmus postablation, RA septum, and inferolateral RA. The mean area of the EEB site was 0.6 ± 0.2 cm2. A mean of 79.5% ± 18.6% of unipolar electrograms at the EEB site demonstrated an rS morphology. The mean distance and conduction velocity from the line of endocardial block to the EEB site at the posterior RA was 13.6 ± 2.3 mm and 59.3 ± 12.3 cm/s, respectively. In 4 patients, entrainment demonstrated that EEB sites were within the circuit and in 1 of these patients critical to arrhythmia maintenance. Activation maps during tachycardia and coronary sinus pacing demonstrated EEB at the same anatomic site. CONCLUSION: EEB sites were demonstrated in stable atrial macroreentry supported by systematic entrainment confirmation and demonstration of the same phenomenon during pacing.


Asunto(s)
Fibrilación Atrial/fisiopatología , Mapeo del Potencial de Superficie Corporal/métodos , Endocardio/fisiopatología , Atrios Cardíacos/fisiopatología , Sistema de Conducción Cardíaco/fisiopatología , Imagenología Tridimensional , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Estimulación Cardíaca Artificial , Ablación por Catéter , Ecocardiografía Transesofágica , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Pronóstico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA