RESUMEN
OBJECTIVES: To describe computed tomography (CT) scanning parameters, volume CT dose index (CTDIvol) and dose-length product (DLP) in paediatric practice and compare them to current diagnostic reference levels (DRLs). METHODS: The survey was conducted in radiology departments of six major university hospitals in France in 2010-2013. Data collection was automatised to extract and standardise information on scanning parameters from DICOM-header files. CTDIvol and DLP were estimated based on Monte Carlo transport simulation and computational reference phantoms. RESULTS: CTDIvol and DLP were derived for 4,300 studies, four age groups and 18 protocols. CTDIvol was lower in younger patients for non-head scans, but did not vary with age for routine head scans. Ratios of 95th to 5th percentile CTDIvol values were 2-4 for most body parts, but 5-7 for abdominal examinations and 4-14 for mediastinum CT with contrast, depending on age. The 75th percentile CTDIvol values were below the national DRLs for chest (all ages) and head and abdominal scans (≥10 years). CONCLUSION: The results suggest the need for a better optimisation of scanning parameters for routine head scans and infrequent protocols with patient age, enhanced standardisation of practices across departments and revision of current DRLs for children. KEY POINTS: ⢠CTDIvol varied little with age for routine head scans. ⢠CTDIvol was lowest in youngest children for chest or abdominal scans. ⢠Individual and inter-department variability warrant enhanced standardisation of practices. ⢠Recent surveys support the need for revised diagnostic reference levels. ⢠More attention should be given to specific protocols (sinuses, neck, spine, mediastinum).