Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Ann Noninvasive Electrocardiol ; 26(3): e12826, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33543816

RESUMEN

BACKGROUND: We investigated whether T-wave heterogeneity (TWH) can identify patients who are at risk for near-term cardiac mortality. METHODS: A nested case-control analysis was performed in the 888 patients admitted to the Emergency Department (ED) of our medical center in July through September 2018 who had ≥2 serial troponin measurement tests within 6 hr for acute coronary syndrome evaluation to rule-in or rule-out the presence of acute myocardial infarction. Patients who died from cardiac causes during 90 days after ED admission were considered cases (n = 20; 10 women) and were matched 1:4 on sex and age with patients who survived during this period (n = 80, 40 women). TWH, that is, interlead splay of T waves, was automatically assessed from precordial leads by second central moment analysis. RESULTS: TWHV4-6 was significantly elevated at ED admission in 12-lead resting ECGs of female patients who died of cardiac causes during the following 90 days compared to female survivors (100 ± 14.9 vs. 40 ± 3.6 µV, p < .0001). TWHV4-6 generated areas under the receiver-operating characteristic (ROC) curve (AUC) of 0.933 in women (p < .0001) and 0.573 in men (p = .4). In women, the ROC-guided 48-µV TWHV4-6 cut point for near-term cardiac mortality produced an adjusted odds ratio of 121.37 (95% CI: 2.89-6,699.84; p = .02) with 100% sensitivity and 82.5% specificity. In Kaplan-Meier survival analysis, TWHV4-6  ≥ 48 µV predicted cardiac mortality in women during 90-day follow-up with a hazard ratio of 27.84 (95% CI: 7.29-106.36, p < .0001). CONCLUSION: Elevated TWHV4-6 is associated with near-term cardiac mortality among women evaluated for acute coronary syndrome.


Asunto(s)
Síndrome Coronario Agudo/complicaciones , Síndrome Coronario Agudo/mortalidad , Electrocardiografía/métodos , Servicio de Urgencia en Hospital , Infarto del Miocardio/complicaciones , Infarto del Miocardio/mortalidad , Síndrome Coronario Agudo/fisiopatología , Anciano , Estudios de Casos y Controles , Femenino , Humanos , Masculino , Infarto del Miocardio/fisiopatología , Medición de Riesgo , Factores Sexuales
2.
J Cardiovasc Electrophysiol ; 31(1): 205-213, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31749267

RESUMEN

INTRODUCTION: Inhaled flecainide significantly alters atrial electrical properties with the potential to terminate atrial fibrillation (AF) efficiently by optimizing dose and drug formulation. METHODS: Seventeen Yorkshire pigs were studied. Intrapericardial acetylcholine and burst pacing were used to induce AF. Effects of a novel cyclodextrin formulation (hydroxypropyl-ß-cyclodextrin [HPßCD]) of flecainide (75 mg/mL, 0.5 or 1.0 mg/kg, bolus) instilled intratracheally at 2 minutes after AF initiation were studied. Concentration time-area analyses of flecainide HPßCD were compared to the traditional acetate formulation. RESULTS: Intratracheal instillation of flecainide HPßCD accelerated the conversion of AF to sinus rhythm in a dose-proportional manner, shortening AF duration by 47% (P = .014) and 79% (P = .002) at the lower and higher doses, respectively, compared to intratracheal sterile water placebo. AF dominant frequency was reduced by 11% (P = .04) and 29% (P = .004) respective to dose. At 2 minutes after intratracheal flecainide HPßCD, atrial depolarization (Pa ) duration increased by 12% (P = .02) and 17% (P = .009) at the lower and higher doses, respectively. At this time, the PR interval was prolonged by 9% (P = .04 for the higher dose) and AV node conduction was slowed, decreasing the ventricular rate during AF by 16% (P = .002) and 28% (P = .007) for the lower and higher doses. Flecainide HPßCD achieved the more efficient conversion of AF than the acetate formulation, reflected in a markedly reduced area under the curve (P = .04). CONCLUSION: Intratracheal instillation of the new flecainide HPßCD formulation effectively terminates AF through efficient multimodal actions including slowing of atrial conduction velocity and decreasing AF dominant frequency, allowing reduced net drug delivery and inhalation time.


Asunto(s)
Antiarrítmicos/administración & dosificación , Fibrilación Atrial/tratamiento farmacológico , Flecainida/administración & dosificación , Sistema de Conducción Cardíaco/efectos de los fármacos , Frecuencia Cardíaca/efectos de los fármacos , 2-Hidroxipropil-beta-Ciclodextrina/química , Potenciales de Acción/efectos de los fármacos , Administración por Inhalación , Animales , Antiarrítmicos/química , Fibrilación Atrial/fisiopatología , Modelos Animales de Enfermedad , Relación Dosis-Respuesta a Droga , Composición de Medicamentos , Flecainida/química , Sistema de Conducción Cardíaco/fisiopatología , Masculino , Sus scrofa , Factores de Tiempo
3.
J Cardiovasc Pharmacol ; 75(2): 135-140, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31789885

RESUMEN

BACKGROUND: Safe, effective pulmonary delivery of cardioactive agents in humans is under development. OBJECTIVES: We examined whether intratracheal delivery of metoprolol can reduce ventricular rate during atrial fibrillation (AF) and accelerate conversion to sinus rhythm. METHODS: In 7 closed-chest, anesthetized Yorkshire pigs, AF was induced by intrapericardial infusion of acetylcholine (1 mL of 102.5-mM solution) followed by atrial burst pacing and was allowed to continue for 2 minutes before intratracheal instillation of sterile water or metoprolol (0.2-mg/kg bolus) using a catheter positioned at the bifurcation of the main bronchi. High-resolution electrograms were obtained from catheters fluoroscopically positioned in the right atrium and left ventricle. RESULTS: Rapid intratracheal instillation of metoprolol caused a 32-beat/min reduction in ventricular rate during AF (from 272 ± 13.7 to 240 ± 12.6 beats/min, P = 0.008) and a 2.3-minute reduction in AF duration (from 10.3 ± 2.0 to 8.0 ± 1.4 minutes, P = 0.018) compared with sterile water control. Conversion of AF to sinus rhythm was associated with rapid restoration (5-6 minutes) of heart rate and arterial blood pressure toward control values. Intratracheal metoprolol reduced AF dominant frequency by 31% (from 8.7 ± 0.9 to 6.0 ± 1.1 Hz, P = 0.04) compared with control and resulted in a trend toward a 5% increase in PR interval (from 174 ± 11.2 to 182 ± 11.4 ms, P = 0.07). CONCLUSIONS: Intratracheal delivery of metoprolol effectively reduces ventricular rate during AF and accelerates conversion to normal sinus rhythm in a pig model of acetylcholine-induced AF.


Asunto(s)
Antagonistas de Receptores Adrenérgicos beta 1/administración & dosificación , Antiarrítmicos/administración & dosificación , Fibrilación Atrial/tratamiento farmacológico , Frecuencia Cardíaca/efectos de los fármacos , Metoprolol/administración & dosificación , Función Ventricular Izquierda/efectos de los fármacos , Administración por Inhalación , Animales , Presión Arterial/efectos de los fármacos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Modelos Animales de Enfermedad , Electrocardiografía , Masculino , Sus scrofa , Factores de Tiempo
4.
Eur Heart J Cardiovasc Imaging ; 22(11): 1341-1349, 2021 10 19.
Artículo en Inglés | MEDLINE | ID: mdl-32620962

RESUMEN

AIMS: We analysed whether incorporating electrocardiographic interlead T-wave heterogeneity (TWH) with myocardial perfusion imaging (MPI) during pharmacologic stress improves detection of flow-limiting lesions (FLL). METHODS AND RESULTS: Medical records of all 103 patients at our institution who underwent stress testing with regadenoson (0.4 mg IV bolus) within 3 months of coronary angiography from September 2017 to March 2019 were studied. Cases (N = 59) had angiographically significant FLL (≥50% of left main or ≥70% of other epicardial coronary arteries ≥2 mm in diameter); controls (N = 44) were normal or had non-FLL. TWH, i.e., interlead splay of T waves, was assessed from precordial leads V4-6 by second central moment analysis. Maximum TWHV4-6 levels during regadenoson stress were 68% higher in cases than in controls (P < 0.0001). TWHV4-6 generated areas under the receiver-operating characteristic (ROC) curve of 0.79 in men (P < 0.0001) and 0.71 in women (P = 0.007). In men, the ROC-guided 54-µV TWHV4-6 cut-point for FLL produced adjusted odds of 7.3 [95% confidence interval (CI): 1.3-41.5, P = 0.03], 79% sensitivity, and 78% specificity. In women, the ROC-guided 35-µV TWHV4-6 cut-point produced adjusted odds of 4.5 (95% CI: 1.1-18.9, P = 0.04), 84% sensitivity, and 52% specificity. Adding TWHV4-6 to MPI determinations reduced false-positive results by 70%, more than doubled true-negative results, and improved adjusted odds ratio to 6.8 (95% CI: 2.2-21.4, P = 0.001) with specificity of 78% in men and 86% in women. CONCLUSION: This observational study is the first to demonstrate the benefit of combining TWHV4-6 with MPI to enhance FLL detection during MPI with regadenoson in both men and women.


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Imagen de Perfusión Miocárdica , Angiografía Coronaria , Estenosis Coronaria/diagnóstico por imagen , Femenino , Humanos , Masculino , Purinas/efectos adversos , Pirazoles/efectos adversos
5.
Heart Rhythm ; 17(11): 1887-1896, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32497764

RESUMEN

BACKGROUND: Reliable quantitative preimplantation predictors of response to cardiac resynchronization therapy (CRT) are needed. OBJECTIVE: We tested the utility of preimplantation R-wave and T-wave heterogeneity (RWH and TWH, respectively) compared to standard QRS complex duration in identifying mechanical super-responders to CRT and mortality risk. METHODS: We analyzed resting 12-lead electrocardiographic recordings from all 155 patients who received CRT devices between 2006 and 2018 at our institution and met class I and IIA American College of Cardiology/American Heart Association/Heart Rhythm Society guidelines with echocardiograms before and after implantation. Super-responders (n=35, 23%) had ≥20% increase in left ventricular ejection fraction and/or ≥20% decrease in left ventricular end-systolic diameter and were compared with non-super-responders (n=120, 77%), who did not meet these criteria. RWH and TWH were measured using second central moment analysis. RESULTS: Among patients with non-left bundle branch block (LBBB), preimplantation RWH was significantly lower in super-responders than in non-super-responders in 3 of 4 lead sets (P=.001 to P=.038) and TWH in 2 lead sets (both, P=.05), with the corresponding areas under the curve (RWH: 0.810-0.891, P<.001; TWH: 0.759-0.810, P≤.005). No differences were observed in the LBBB group. Preimplantation QRS complex duration also did not differ between super-responders and non-super-responders among patients with (P=.856) or without (P=.724) LBBB; the areas under the curve were nonsignificant (both, P=.69). RWHV1-3LILII ≥ 420 µV predicted 3-year all-cause mortality in the entire cohort (P=.037), with a hazard ratio of 7.440 (95% confidence interval 1.015-54.527; P=.048); QRS complex duration ≥ 150 ms did not predict mortality (P=.27). CONCLUSION: Preimplantation interlead electrocardiographic heterogeneity but not QRS complex duration predicts mechanical super-response to CRT in patients with non-LBBB.


Asunto(s)
Bloqueo de Rama/terapia , Terapia de Resincronización Cardíaca/métodos , Electrocardiografía , Frecuencia Cardíaca/fisiología , Volumen Sistólico/fisiología , Función Ventricular Izquierda/fisiología , Anciano , Bloqueo de Rama/fisiopatología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Estudios Retrospectivos
6.
Int J Cardiol ; 298: 32-38, 2020 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-31412992

RESUMEN

BACKGROUND: Despite widespread use of ETT and vasodilator-stress with myocardial perfusion imaging (MPI) for noninvasive detection of flow-limiting coronary artery disease, there is continued need to improve diagnostic accuracy. We examined whether measurement of interlead T-wave heterogeneity (TWH) during exercise tolerance testing (ETT) or pharmacologic stress testing improves detection of stenoses in large epicardial coronary arteries. METHODS: All 137 patients at our institution who underwent diagnostic coronary angiography within 0 to 5 days after ETT (N = 81) or dipyridamole IV infusion (N = 58) in 2016 were studied, including 2 patients with both tests. Cases (N = 93) had angiographically significant stenosis (≥50% of left main or ≥ 70% of an epicardial coronary artery ≥2 mm in diameter); controls (N = 44) did not. TWH, i.e., interlead splay of T waves, was determined by second central moment analysis from precordial leads by an investigator blinded to angiographic results. RESULTS: At rest, TWH levels were similar for cases and controls. ETT and dipyridamole stress testing increased TWH by 69% (p < 0.0001) and 27% (p < 0.0001), respectively, in cases. In controls, TWH did not change. Areas under the ROC curves for TWH increase for any flow-limiting coronary artery stenosis were 0.737 (p < 0.0001) for ETT and 0.818 (p < 0.0001) for dipyridamole stress testing. By contrast, neither ST-segment changes during ETT (p = 0.12) nor MPI during dipyridamole stress testing (p = 0.60) discriminated cases from controls. CONCLUSIONS: TWH measurement is a novel method that improves detection of angiographically confirmed flow-limiting stenoses in large epicardial coronary arteries during both ETT and MPI during pharmacologic stress testing with dipyridamole.


Asunto(s)
Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/fisiopatología , Electrocardiografía/métodos , Prueba de Esfuerzo/métodos , Tolerancia al Ejercicio/fisiología , Imagen de Perfusión Miocárdica/métodos , Anciano , Angiografía Coronaria/métodos , Estenosis Coronaria/terapia , Femenino , Humanos , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA