1.
NMR Biomed ; : e5147, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38561247

RESUMEN

Partial Fourier encoding is popular in single-shot (ss) diffusion-weighted (DW) echo planar imaging (EPI) because it enables a shorter echo time (TE) and, hence, improves the signal-to-noise-ratio. Motion during diffusion encoding causes k-space shifting and dispersion, which compromises the quality of the homodyne reconstruction. This work provides a comprehensive understanding of the artifacts in homodyne reconstruction of partial Fourier ss-DW-EPI data in the presence of motion-induced phase and proposes the motion-induced phase-corrected homodyne (mpc-hdyne) reconstruction method to ameliorate these artifacts. Simulations with different types of motion-induced phase were performed to provide an understanding of the potential artifacts that occur in the homodyne reconstruction of partial Fourier ss-DW-EPI data. To correct for the artifacts, the mpc-hdyne reconstruction is proposed. The algorithm recenters k-space, updates the partial Fourier factor according to detected global k-space shifts, and removes low-resolution nonlinear phase before the conventional homodyne reconstruction. The mpc-hdyne reconstruction is tested on both simulation and in vivo data. Motion-induced phase can cause signal overestimation, worm artifacts, and signal loss in partial Fourier ss-DW-EPI data with the conventional homodyne reconstruction. Simulation and in vivo data showed that the proposed mpc-hdyne reconstruction ameliorated artifacts, yielding higher quality DW images compared with conventional homodyne reconstruction. Based on the understanding of the artifacts in homodyne reconstruction of partial Fourier ss-DW-EPI data, the mpc-hdyne reconstruction was proposed and showed superior performance compared with the conventional homodyne reconstruction on both simulation and in vivo data.

2.
MAGMA ; 2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38743376

RESUMEN

PURPOSE: To investigate the effect of respiratory motion in terms of signal loss in prostate diffusion-weighted imaging (DWI), and to evaluate the usage of partial Fourier in a free-breathing protocol in a clinically relevant b-value range using both single-shot and multi-shot acquisitions. METHODS: A controlled breathing DWI acquisition was first employed at 3 T to measure signal loss from deep breathing patterns. Single-shot and multi-shot (2-shot) acquisitions without partial Fourier (no pF) and with partial Fourier (pF) factors of 0.75 and 0.65 were employed in a free-breathing protocol. The apparent SNR and ADC values were evaluated in 10 healthy subjects to measure if low pF factors caused low apparent SNR or overestimated ADC. RESULTS: Controlled breathing experiments showed a difference in signal coefficient of variation between shallow and deep breathing. In free-breathing single-shot acquisitions, the pF 0.65 scan showed a significantly (p < 0.05) higher apparent SNR than pF 0.75 and no pF in the peripheral zone (PZ) of the prostate. In the multi-shot acquisitions in the PZ, pF 0.75 had a significantly higher apparent SNR than 0.65 pF and no pF. The single-shot pF 0.65 scan had a significantly lower ADC than single-shot no pF. CONCLUSION: Deep breathing patterns can cause intravoxel dephasing in prostate DWI. For single-shot acquisitions at a b-value of 800 s/mm2, any potential risks of motion-related artefacts at low pF factors (pF 0.65) were outweighed by the increase in signal from a lower TE, as shown by the increase in apparent SNR. In multi-shot acquisitions however, the minimum pF factor should be larger, as shown by the lower apparent SNR at low pF factors.

3.
Radiology ; 308(3): e230427, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37750774

RESUMEN

Background Deep learning (DL) reconstructions can enhance image quality while decreasing MRI acquisition time. However, DL reconstruction methods combined with compressed sensing for prostate MRI have not been well studied. Purpose To use an industry-developed DL algorithm to reconstruct low-resolution T2-weighted turbo spin-echo (TSE) prostate MRI scans and compare these with standard sequences. Materials and Methods In this prospective study, participants with suspected prostate cancer underwent prostate MRI with a Cartesian standard-resolution T2-weighted TSE sequence (T2C) and non-Cartesian standard-resolution T2-weighted TSE sequence (T2NC) between August and November 2022. Additionally, a low-resolution Cartesian DL-reconstructed T2-weighted TSE sequence (T2DL) with compressed sensing DL denoising and resolution upscaling reconstruction was acquired. Image sharpness was assessed qualitatively by two readers using a five-point Likert scale (from 1 = nondiagnostic to 5 = excellent) and quantitatively by calculating edge rise distance. The Friedman test and one-way analysis of variance with post hoc Bonferroni and Tukey tests, respectively, were used for group comparisons. Prostate Imaging Reporting and Data System (PI-RADS) score agreement between sequences was compared by using Cohen κ. Results This study included 109 male participants (mean age, 68 years ± 8 [SD]). Acquisition time of T2DL was 36% and 29% lower compared with that of T2C and T2NC (mean duration, 164 seconds ± 20 vs 257 seconds ± 32 and 230 seconds ± 28; P < .001 for both). T2DL showed improved image sharpness compared with standard sequences using both qualitative (median score, 5 [IQR, 4-5] vs 4 [IQR, 3-4] for T2C and 4 [IQR, 3-4] for T2NC; P < .001 for both) and quantitative (mean edge rise distance, 0.75 mm ± 0.39 vs 1.15 mm ± 0.68 for T2C and 0.98 mm ± 0.65 for T2NC; P < .001 and P = .01) methods. PI-RADS score agreement between T2NC and T2DL was excellent (κ range, 0.92-0.94 [95% CI: 0.87, 0.98]). Conclusion DL reconstruction of low-resolution T2-weighted TSE sequences enabled accelerated acquisition times and improved image quality compared with standard acquisitions while showing excellent agreement with conventional sequences for PI-RADS ratings. Clinical trial registration no. NCT05820113 © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Turkbey in this issue.


Asunto(s)
Aprendizaje Profundo , Neoplasias de la Próstata , Humanos , Masculino , Anciano , Imagen por Resonancia Magnética , Estudios Prospectivos , Próstata/diagnóstico por imagen , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/cirugía
4.
Magn Reson Med ; 89(1): 144-160, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36098347

RESUMEN

PURPOSE: To assess the effect of respiratory motion and cardiac driven pulsation in renal DWI and to examine asymmetrical velocity-compensated diffusion encoding waveforms for robust ADC mapping in the kidneys. METHODS: The standard monopolar Stejskal-Tanner pulsed gradient spin echo (pgse) and the asymmetric bipolar velocity-compensated (asym-vc) diffusion encoding waveforms were used for coronal renal DWI at 3T. The robustness of the ADC quantification in the kidneys was tested with the aforementioned waveforms in respiratory-triggered and breath-held cardiac-triggered scans at different trigger delays in 10 healthy subjects. RESULTS: The pgse waveform showed higher ADC values in the right kidney at short trigger delays in comparison to longer trigger delays in the respiratory triggered scans when the diffusion gradient was applied in the feet-head (FH) direction. The coefficient of variation over all respiratory trigger delays, averaged over all subjects was 0.15 for the pgse waveform in the right kidney when diffusion was measured in the FH direction; the corresponding coefficient of variation for the asym-vc waveform was 0.06. The effect of cardiac driven pulsation was found to be small in comparison to the effect of respiratory motion. CONCLUSION: Short trigger delays in respiratory-triggered scans can cause higher ADC values in comparison to longer trigger delays in renal DWI, especially in the right kidney when diffusion is measured in the FH direction. The asym-vc waveform can reduce ADC variation due to respiratory motion in respiratory-triggered scans at the cost of reduced SNR compared to the pgse waveform.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Riñón , Humanos , Imagen de Difusión por Resonancia Magnética/métodos , Movimiento (Física) , Riñón/diagnóstico por imagen , Corazón/diagnóstico por imagen , Difusión , Reproducibilidad de los Resultados
5.
Pediatr Radiol ; 53(7): 1285-1299, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36255456

RESUMEN

Longer examination time, need for anesthesia in smaller children and the inability of most children to hold their breath are major limitations of MRI in pediatric body imaging. Fortunately, with technical advances, many new and upcoming MRI sequences are overcoming these limitations. Advances in data acquisition and k-space sampling methods have enabled sequences with improved temporal and spatial resolution, and minimal artifacts. Sequences to minimize movement artifacts mainly utilize radial k-space filling, and examples include the stack-of-stars method for T1-weighted imaging and the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER)/BLADE method for T2-weighted imaging. Similarly, the sequences with improved temporal resolution and the ability to obtain multiple phases in a single breath-hold in dynamic imaging mainly use some form of partial k-space filling method. New sequences use a variable combination of data sampling methods like compressed sensing, golden-angle radial k-space filling, parallel imaging and partial k-space filling to achieve free-breathing, faster sequences that could be useful for pediatric abdominal and thoracic imaging. Simultaneous multi-slice method has improved diffusion-weighted imaging (DWI) with reduction in scan time and artifacts. In this review, we provide an overview of data sampling methods like parallel imaging, compressed sensing, radial k-space sampling, partial k-space sampling and simultaneous multi-slice. This is followed by newer available and upcoming sequences for T1-, T2- and DWI based on these other advances. We also discuss the Dixon method and newer approaches to reducing metal artifacts.


Asunto(s)
Medios de Contraste , Procesamiento de Imagen Asistido por Computador , Humanos , Niño , Procesamiento de Imagen Asistido por Computador/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Respiración , Artefactos , Imagenología Tridimensional , Aumento de la Imagen/métodos
6.
Eur Radiol ; 32(12): 8376-8385, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35751695

RESUMEN

OBJECTIVES: To evaluate a compressed sensing artificial intelligence framework (CSAI) to accelerate MRI acquisition of the ankle. METHODS: Thirty patients were scanned at 3T. Axial T2-w, coronal T1-w, and coronal/sagittal intermediate-w scans with fat saturation were acquired using compressed sensing only (12:44 min, CS), CSAI with an acceleration factor of 4.6-5.3 (6:45 min, CSAI2x), and CSAI with an acceleration factor of 6.9-7.7 (4:46 min, CSAI3x). Moreover, a high-resolution axial T2-w scan was obtained using CSAI with a similar scan duration compared to CS. Depiction and presence of abnormalities were graded. Signal-to-noise and contrast-to-noise were calculated. Wilcoxon signed-rank test and Cohen's kappa were used to compare CSAI with CS sequences. RESULTS: The correlation was perfect between CS and CSAI2x (κ = 1.0) and excellent for CS and CSAI3x (κ = 0.86-1.0). No significant differences were found for the depiction of structures between CS and CSAI2x and the same abnormalities were detected in both protocols. For CSAI3x the depiction was graded lower (p ≤ 0.001), though most abnormalities were also detected. For CSAI2x contrast-to-noise fluid/muscle was higher compared to CS (p ≤ 0.05), while no differences were found for other tissues. Signal-to-noise and contrast-to-noise were higher for CSAI3x compared to CS (p ≤ 0.05). The high - resolution axial T2-w sequence specifically improved the depiction of tendons and the tibial nerve (p ≤ 0.005). CONCLUSIONS: Acquisition times can be reduced by 47% using CSAI compared to CS without decreasing diagnostic image quality. Reducing acquisition times by 63% is feasible but should be reserved for specific patients. The depiction of specific structures is improved using a high-resolution axial T2-w CSAI scan. KEY POINTS: • Prospective study showed that CSAI enables reduction in acquisition times by 47% without decreasing diagnostic image quality. • Reducing acquisition times by 63% still produces images with an acceptable diagnostic accuracy but should be reserved for specific patients. • CSAI may be implemented to scan at a higher resolution compared to standard CS images without increasing acquisition times.


Asunto(s)
Artefactos , Aprendizaje Profundo , Humanos , Relación Señal-Ruido , Tobillo/diagnóstico por imagen , Estudios Prospectivos , Inteligencia Artificial , Imagen por Resonancia Magnética/métodos , Aceleración , Imagenología Tridimensional/métodos
7.
MAGMA ; 35(5): 827-841, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34894335

RESUMEN

OBJECTIVE : To experimentally characterize the effectiveness of a gradient nonlinearity correction method in removing ADC bias for different motion-compensated diffusion encoding waveforms. METHODS: The diffusion encoding waveforms used were the standard monopolar Stejskal-Tanner pulsed gradient spin echo (pgse) waveform, the symmetric bipolar velocity-compensated waveform (sym-vc), the asymmetric bipolar velocity-compensated waveform (asym-vc) and the asymmetric bipolar partial velocity-compensated waveform (asym-pvc). The effectiveness of the gradient nonlinearity correction method using the spherical harmonic expansion of the gradient coil field was tested with the aforementioned waveforms in a phantom and in four healthy subjects. RESULTS: The gradient nonlinearity correction method reduced the ADC bias in the phantom experiments for all used waveforms. The range of the ADC values over a distance of ± 67.2 mm from isocenter reduced from 1.29 × 10-4 to 0.32 × 10-4 mm2/s for pgse, 1.04 × 10-4 to 0.22 × 10-4 mm2/s for sym-vc, 1.22 × 10-4 to 0.24 × 10-4 mm2/s for asym-vc and 1.07 × 10-4 to 0.11 × 10-4 mm2/s for asym-pvc. The in vivo results showed that ADC overestimation due to motion or bright vessels can be increased even further by the gradient nonlinearity correction. CONCLUSION: The investigated gradient nonlinearity correction method can be used effectively with various motion-compensated diffusion encoding waveforms. In coronal liver DWI, ADC errors caused by motion and residual vessel signal can be increased even further by the gradient nonlinearity correction.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Procesamiento de Imagen Asistido por Computador , Humanos , Imagen de Difusión por Resonancia Magnética/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Hígado/diagnóstico por imagen , Movimiento (Física)
8.
Eur Radiol ; 31(11): 8399-8407, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33884471

RESUMEN

OBJECTIVES: To compare the image quality and diagnostic performance of 2D MRCP to those of breath-hold 3D MRCP using compressed sensing (CS-MRCP) and gradient and spin-echo (GRASE-MRCP) at 3T. METHODS: From January to November 2018, patients who underwent pancreatobiliary MRI including 2D MRCP and two breath-hold 3D MRCP using CS and GRASE at 3T were included. Three radiologists independently evaluated image quality, motion artifact, and pancreatic cyst conspicuity. Diagnostic performance was assessed for bile duct anatomic variation, bile duct, and pancreatic diseases using a composite algorithm as reference standards. Pancreatic lesion detectability and conspicuity were evaluated using JAFROC and generalized estimating equation analysis. RESULTS: One hundred patients (male = 50) were included. Bile duct anatomic variation, bile duct and pancreatic diseases were present in respectively 31, 15, and 79 patients. Breath-hold 3D MRCP provided better image quality than 2D MRCP (3.5 ± 0.6 in 2D MRCP; 4.0 ± 0.7 in GRASE-MRCP and 3.9 ± 0.8 in CS-MRCP, p < 0.001 for both). There was no difference in motion artifact between 2D and breath-hold 3D MRCP (p = 0.1). Breath-hold 3D CS-MRCP provided better pancreatic cyst conspicuity than 2D MRCP (2.7 [95% CI: 2.5-3.0] vs. 2.3 [95% CI: 2.1-2.5], p = 0.001). There were no significant differences between the diagnostic performance of the three sequences in the detection of bile duct anatomic variation or pancreatic lesions (p > 0.05). CONCLUSION: Breath-hold 3D MRCP with GRASE or CS can provide better image quality than 2D MRCP in a comparable scan time. KEY POINTS: • Breath-hold 3D MRCP using compressed sensing (CS) or gradient and spin-echo (GRASE) provided a better image quality with less image blurring than 2D MRCP. • There were no significant differences between 2D MRCP and breath-hold 3D MRCP in either motion artifact or the number of non-diagnostic exams. • There were no significant differences between 2D MRCP and either type of breath-hold 3D MRCP in the diagnosis of bile duct anatomic variation or detection of pancreatic lesions.


Asunto(s)
Pancreatocolangiografía por Resonancia Magnética , Enfermedades Pancreáticas , Artefactos , Contencion de la Respiración , Humanos , Imagenología Tridimensional , Imagen por Resonancia Magnética , Masculino , Enfermedades Pancreáticas/diagnóstico por imagen
9.
Dysphagia ; 36(1): 41-53, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-32200444

RESUMEN

Swallowing muscle strength exercises are effective in restoring swallowing function. In order to perform the exercises with progressive load, the swallow exercise aid (SEA) was developed. Precise knowledge on which muscles are activated with swallowing exercises, especially with the SEA, is lacking. This knowledge would aid in optimizing the training program to target the relevant swallowing muscles, if necessary. Three healthy volunteers performed the three SEA exercises (chin tuck against resistance, jaw opening against resistance and effortful swallow) and three conventional exercises [conventional effortful swallow (cES), Shaker and Masako] in supine position inside an MRI scanner. Fast muscle functional MRI scans (generating quantitative T2-maps) were made immediately before and after the exercises. Median T2 values at rest and after exercise were compared to identify activated muscles. After the three SEA exercises, the suprahyoid, infrahyoid, sternocleidomastoid, and lateral pterygoid muscles showed significant T2 value increase. After the Shaker, the lateral pterygoid muscles did not show such an increase, but the three other muscle groups did. The cES and Masako caused no significant increase in any of these muscle groups. During conventional (Shaker) exercises, the suprahyoid, infrahyoid, and sternocleidomastoid muscles are activated. During the SEA exercises, the suprahyoid, infrahyoid, sternocleidomastoid, and lateral pterygoid muscles are activated. The findings of this explorative study further support the potential of the SEA to improve swallowing rehabilitation.


Asunto(s)
Trastornos de Deglución , Deglución , Electromiografía , Terapia por Ejercicio , Humanos , Imagen por Resonancia Magnética , Músculos del Cuello
10.
Magn Reson Med ; 79(3): 1586-1594, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-28671331

RESUMEN

PURPOSE: To evaluate the performance of a multi-echo spin-echo sequence with k-t undersampling scheme (k-t T2 ) in prostate cancer. METHODS: Phantom experiments were performed at five systems to estimate the bias, short-term repeatability, and reproducibility across all systems expressed with the within-subject coefficient of variation (wCV). Monthly measurements were performed on two systems for long-term repeatability estimation. To evaluate clinical repeatability, two T2 maps (voxel size 0.8 × 0.8 × 3 mm3 ; 5 min) were acquired at separate visits on one system for 13 prostate cancer patients. Repeatability was assessed per patient in relation to spatial resolution. T2 values were compared for tumor, peripheral zone, and transition zone. RESULTS: Phantom measurements showed a small bias (median = -0.9 ms) and good short-term repeatability (median wCV = 0.5%). Long-term repeatability was 0.9 and 1.1% and reproducibility between systems was 1.7%. The median bias observed in patients was -1.1 ms. At voxel level, the median wCV was 15%, dropping to 4% for structures of 0.5 cm3 . The median tumor T2 values (79 ms) were significantly lower (P < 0.001) than in the peripheral zone (149 ms), but overlapped with the transition zone (91 ms). CONCLUSIONS: Reproducible T2 mapping of the prostate is feasible with good spatial resolution in a clinically reasonable scan time, allowing reliable measurement of T2 in structures as small as 0.5 cm3 . Magn Reson Med 79:1586-1594, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Próstata/diagnóstico por imagen , Neoplasias de la Próstata/diagnóstico por imagen , Anciano , Algoritmos , Humanos , Masculino , Persona de Mediana Edad
11.
Eur Radiol ; 28(9): 3721-3728, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-29392471

RESUMEN

OBJECTIVE: To evaluate the clinical feasibility and image quality of breath-hold (BH) three-dimensional (3D) magnetic resonance cholangiopancreatography (MRCP) using a gradient and spin-echo (GRASE) technique compared to the conventional 3D respiratory-triggered (RT)-MRCP using a turbo spin-echo (TSE) sequence at 3 T. METHODS: Sixty-six patients underwent both 3D RT-TSE-MRCP and 3D BH-GRASE-MRCP at 3 T. Three radiologists independently reviewed the visualisation of biliary and pancreatic ducts, image blurring, and overall image quality of the two data sets using four- or five-point scales. The numbers of scans with non-diagnostic or poor image quality were compared between the two scans. RESULTS: The 3D BH-GRASE-MRCP had a significantly better image quality (3.69 ± 0.77 vs. 3.30 ± 1.18, p = 0.005) and less image blurring (3.23 ± 0.94 vs. 3.65 ± 0.57, p = 0.0003) than the 3D RT-TSE-MRCP. In detail, 3D BH-GRASE-MRCP better depicted the common bile duct, cystic duct, and bilateral first intrahepatic duct (all ps < 0.05). The number of scans with non-diagnostic or poor image quality significantly decreased with 3D BH-GRASE-MRCP compared with 3D RT-TSE-MRCP [19.7% (13/66) vs. 1.5% (1/66), p = 0.002]. CONCLUSION: The 3D BH-GRASE-MRCP provided better image quality and a reduced number of non-diagnostic images compared to 3D RT-TSE-MRCP. KEY POINTS: • The GRASE technique enabled 3D MRCP acquisition within a single breath-hold. • The short acquisition time of 3D BH-GRASE-MRCP significantly reduced image blurring. • The 3D BH-GRASE-MRCP had a better image quality than 3D RT-TSE-MRCP. • The number of non-diagnostic scans was reduced with 3D BH-GRASE-MRCP.


Asunto(s)
Enfermedades de los Conductos Biliares/diagnóstico por imagen , Conductos Biliares/diagnóstico por imagen , Pancreatocolangiografía por Resonancia Magnética/métodos , Imagenología Tridimensional/métodos , Enfermedades Pancreáticas/diagnóstico por imagen , Conductos Pancreáticos/diagnóstico por imagen , Adulto , Anciano , Contencion de la Respiración , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Adulto Joven
12.
Magn Reson Med ; 76(6): 1951-1956, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-26667410

RESUMEN

PURPOSE: To explore the effects of high permittivity dielectric pads on the transmit and receive characteristics of a 3 Tesla body coil centered at the thighs, and their implications on image uniformity in receive array applications. THEORY AND METHODS: Transmit and receive profiles of the body coil with and without dielectric pads were simulated and measured in healthy volunteers. Parallel imaging was performed using sensitivity encoding (SENSE) with and without pads. An intensity correction filter was constructed from the measured receive profile of the body coil. RESULTS: Measured and simulated data show that the dielectric pads improve the transmit homogeneity of the body coil in the thighs, but decrease its receive homogeneity, which propagates into reconstruction algorithms in which the body coil is used as a reference. However, by correcting for the body coil reception profile this effect can be mitigated. CONCLUSION: Combining high permittivity dielectric pads with an appropriate body coil receive sensitivity filter improves the image uniformity substantially compared with the situation without pads. Magn Reson Med 76:1951-1956, 2016. © 2015 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Algoritmos , Artefactos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Muslo/anatomía & histología , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Procesamiento de Señales Asistido por Computador
13.
Magn Reson Imaging ; 110: 96-103, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38631532

RESUMEN

PURPOSE: Further acceleration of DWI in diagnostic radiology is desired but challenging mainly due to low SNR in high b-value images and associated bias in quantitative ADC values. Deep learning-based reconstruction and denoising may provide a solution to address this challenge. METHODS: The effects of SNR reduction on ADC bias and variability were investigated using a commercial diffusion phantom and numerical simulations. In the phantom, performance of different reconstruction methods, including conventional parallel (SENSE) imaging, compressed sensing (C-SENSE), and compressed SENSE acceleration with an artificial intelligence deep learning-based technique (C-SENSE AI), was compared at different acceleration factors and flip angles using ROI-based analysis. ADC bias was assessed by Lin's Concordance correlation coefficient (CCC) followed by bootstrapping to calculate confidence intervals (CI). ADC random measurement error (RME) was assessed by the mean coefficient of variation (CV¯) and non-parametric statistical tests. RESULTS: The simulations predicted increasingly negative bias and loss of precision towards lower SNR. These effects were confirmed in phantom measurements of increasing acceleration, for which CCC decreased from 0.947 to 0.279 and CV¯ increased from 0.043 to 0.439, and of decreasing flip angle, for which CCC decreased from 0.990 to 0.063 and CV¯ increased from 0.037 to 0.508. At high acceleration and low flip angle, C-SENSE AI reconstruction yielded best denoised ADC maps. For the lowest investigated flip angle, CCC = {0.630, 0.771 and 0.987} and CV¯={0.508, 0.426 and 0.254} were obtained for {SENSE, C-SENSE, C-SENSE AI}, the improvement by C-SENSE AI being significant as compared to the other methods (CV: p = 0.033 for C-SENSE AI vs. C-SENSE and p < 0.001 for C-SENSE AI vs. SENSE; CCC: non-overlapping CI between reconstruction methods). For the highest investigated acceleration factor, CCC = {0.479,0.926,0.960} and CV¯={0.519,0.119,0.118} were found, confirming the reduction of bias and RME by C-SENSE AI as compared to C-SENSE (by trend) and to SENSE (CV: p < 0.001; CCC: non-overlapping CI). CONCLUSION: ADC bias and random measurement error in DWI at low SNR, typically associated with scan acceleration, can be effectively reduced by deep-learning based C-SENSE AI reconstruction.


Asunto(s)
Aprendizaje Profundo , Imagen de Difusión por Resonancia Magnética , Procesamiento de Imagen Asistido por Computador , Fantasmas de Imagen , Relación Señal-Ruido , Imagen de Difusión por Resonancia Magnética/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Humanos , Reproducibilidad de los Resultados , Algoritmos , Simulación por Computador
14.
Eur J Radiol ; 175: 111445, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38537605

RESUMEN

PURPOSE: To evaluate the feasibility of a free-breathing sequence (4D FreeBreathing) combined with Compressed SENSE in dynamic contrast-enhanced pancreatic MRI and compare it with a breath-holding sequence (eTHRIVE). METHOD: Patients who underwent pancreatic MRI, either eTHRIVE or 4D FreeBreathing, from April 2022 to November 2023 were included in this retrospective study. Two radiologists, who were unaware of the scan sequence, independently and randomly reviewed the images at the precontrast, pancreatic, portal venous, and equilibrium phases and assigned confidence scores for motion and streaking artifacts, pancreatic sharpness, and overall image quality using a 5-point scale. Furthermore, the radiologists assessed the appropriateness of the scan timing of the pancreatic phase. Mann-Whitney U and Fisher's exact tests were conducted to compare the confidence scores and adequacy of the pancreatic phase scan timing between eTHRIVE and 4D FreeBreathing. RESULTS: Overall, 48 patients (median age, 71 years; interquartile range, 64-77 years; 24 women) were included. Among them, 20 patients (42%) were scanned using 4D FreeBreathing. The 4D FreeBreathing showed moderate streaking artifact but improved motion artifact (P <.001-.17) at all phases. Pancreatic sharpness and overall image quality were almost comparable between two sequences (P = .17-.96). All 20 examinations in 4D FreeBreathing showed appropriate pancreatic phase images, but only 16 (57%; P <.001 for reviewer 1) and 18 (64%; P = .003 for reviewer 2) examinations showed it in eTHRIVE. CONCLUSION: The use of 4D FreeBreathing combined with Compressed SENSE was feasible in pancreatic MRI and provided appropriate pancreatic phase images in all examinations.


Asunto(s)
Medios de Contraste , Estudios de Factibilidad , Imagen por Resonancia Magnética , Humanos , Femenino , Masculino , Persona de Mediana Edad , Anciano , Estudios Retrospectivos , Imagen por Resonancia Magnética/métodos , Artefactos , Respiración , Aumento de la Imagen/métodos , Contencion de la Respiración , Compresión de Datos/métodos , Neoplasias Pancreáticas/diagnóstico por imagen , Páncreas/diagnóstico por imagen , Enfermedades Pancreáticas/diagnóstico por imagen
15.
Magn Reson Med ; 69(6): 1665-9, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22847672

RESUMEN

In this work, an extension of the Cartesian sensitivity encoding (SENSE) parallel imaging framework is proposed. In the well-known SENSE solution, the overdetermined reconstruction inversion problem is optimized to get the highest signal-to-noise ratio in the image. In this extension, the probability of artifacts due to incorrect knowledge of the receiver coil sensitivities is also taken into account. This is realized by assuming an uncertainty in measured receiver coil sensitivities to enable weighting of residual artifact level and signal-to-noise ratio in the inversion problem. This inversion problem can still be solved by a least-squares optimization without the need of any complex iterative scheme. Results in abdominal imaging show that artifact levels can be substantially reduced, at the cost of a signal-to-noise ratio penalty. The size of the signal-to-noise ratio penalty depends on the assumed inaccuracy of the coil sensitivities, sensitivity encoding acceleration factor, and coil configuration.


Asunto(s)
Algoritmos , Artefactos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Aumento de la Imagen/instrumentación , Interpretación de Imagen Asistida por Computador/instrumentación , Hígado/anatomía & histología , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Procesamiento de Señales Asistido por Computador
16.
Tomography ; 9(5): 1839-1856, 2023 10 06.
Artículo en Inglés | MEDLINE | ID: mdl-37888738

RESUMEN

Cardiac motion causes unpredictable signal loss in respiratory-triggered diffusion-weighted magnetic resonance imaging (DWI) of the liver, especially inside the left lobe. The left liver lobe may thus be frequently neglected in the clinical evaluation of liver DWI. In this work, a data-driven algorithm that relies on the statistics of the signal in the left liver lobe to mitigate the motion-induced signal loss is presented. The proposed data-driven algorithm utilizes the exclusion of severely corrupted images with subsequent spatially dependent image scaling based on a signal-loss model to correctly combine the multi-average diffusion-weighted images. The signal in the left liver lobe is restored and the liver signal is more homogeneous after applying the proposed algorithm. Furthermore, overestimation of the apparent diffusion coefficient (ADC) in the left liver lobe is reduced. The proposed algorithm can therefore contribute to reduce the motion-induced bias in DWI of the liver and help to increase the diagnostic value of DWI in the left liver lobe.


Asunto(s)
Artefactos , Hígado , Estudios Retrospectivos , Reproducibilidad de los Resultados , Hígado/diagnóstico por imagen , Movimiento (Física) , Imagen de Difusión por Resonancia Magnética/métodos
17.
Invest Radiol ; 57(7): 470-477, 2022 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-35136004

RESUMEN

OBJECTIVE: Robust dynamic contrast-enhanced T1-weighted images are crucial for accurate detection and categorization of focal liver lesions in liver/abdominal magnetic resonance imaging (MRI). As optimal dynamic imaging usually requires multiple breath-holds, its inherent susceptibility to motion artifacts frequently results in degraded image quality in incompliant patients. Because free-breathing imaging may overcome this drawback, the intention of this study was to evaluate a dynamic MRI sequence acquired during free breathing using the variable density, elliptical centric golden angle radial stack-of-stars radial sampling scheme, which so far has not been implemented in 4-dimensional applications. MATERIALS AND METHODS: In a prospective pilot study, 27 patients received a routine abdominal MRI protocol including the prototype free-breathing sequence (4DFreeBreathing) for dynamic imaging. This enables more convenient and faster reconstruction through variable density, elliptical centric golden angle radial stack-of-stars without the use of additional reconstruction hardware, and even higher motion robustness through soft-gating. A standard breath-hold sequence performed subsequently served as reference standard. Of the continuous dynamic data sets, each dynamic phase was analyzed regarding image quality, motion artifacts and vessel conspicuity using 5-point Likert scales. Furthermore, correct timing of the late arterial phase was compared with the preexaminations. RESULTS: 4DFreeBreathing delivered motion-free dynamic images with high temporal resolution in each subject. Overall image quality scores were rated good or excellent for 4DFreeBreathing and the gold standard without significant differences (P = 0.34). There were significantly less motion artifacts in the 4DFreeBreathing sequence (P < 0.0001), whereas vessel conspicuity in each dynamic phase was comparable for both groups (P = 0.45, P > 0.99, P = 0.22, respectively). Correct timing of the late arterial phase could be achieved in 27 of 27 (100%) examinations using 4DFreeBreathing versus 35 of 53 (66%) preexaminations using gold standard (P < 0.001). CONCLUSION: The benefit of convenient and fast image reconstruction combined with the superiority in motion robustness and timing compared with standard breath hold sequences renders 4DFreeBreathing an attractive alternative to existing free-breathing techniques in dynamic liver MRI.


Asunto(s)
Medios de Contraste , Aumento de la Imagen , Artefactos , Estudios de Factibilidad , Humanos , Aumento de la Imagen/métodos , Imagenología Tridimensional/métodos , Hígado/diagnóstico por imagen , Hígado/patología , Imagen por Resonancia Magnética/métodos , Proyectos Piloto , Estudios Prospectivos , Respiración
18.
Cancers (Basel) ; 14(23)2022 Nov 22.
Artículo en Inglés | MEDLINE | ID: mdl-36497223

RESUMEN

BACKGROUND: To assess the performance of prospectively accelerated and deep learning (DL) reconstructed T2-weighted (T2w) imaging in volunteers and patients with histologically proven prostate cancer (PCa). METHODS: Prospectively undersampled T2w datasets were acquired with acceleration factors of 1.7 (reference), 3.4 and 4.8 in 10 healthy volunteers and 23 patients with histologically proven PCa. Image reconstructions using compressed SENSE (C-SENSE) and a combination of C-SENSE and DL-based artificial intelligence (C-SENSE AI) were analyzed. Qualitative image comparison was performed using a 6-point Likert scale (overall image quality, noise, motion artifacts, lesion detection, diagnostic certainty); the T2 and PI-RADS scores were compared between the two reconstructions. Additionally, quantitative image parameters were assessed (apparent SNR, apparent CNR, lesion size, line profiles). RESULTS: All C-SENSE AI-reconstructed images received a significantly higher qualitative rating compared to the C-SENSE standard images. Analysis of the quantitative parameters supported this finding, with significantly higher aSNR and aCNR. The line profiles demonstrated a significantly steeper signal change at the border of the prostatic lesion and the adjacent normal tissue in the C-SENSE AI-reconstructed images, whereas the T2 and PI-RADS scores as well as the lesion size did not differ. CONCLUSION: In this prospective study, we demonstrated the clinical feasibility of a novel C-SENSE AI reconstruction enabling a 58% acceleration in T2w imaging of the prostate while obtaining significantly better image quality.

19.
Magn Reson Imaging ; 87: 1-6, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34808306

RESUMEN

OBJECTIVES: To prospectively evaluate an L1 regularized iterative SENSE reconstruction (L1-R SENSE) to eliminate band-like artifacts frequently seen with parallel imaging (SENSE) at high acceleration factors in high resolution diffusion weighted magnetic resonance imaging of the pancreas. METHODS: Fourteen patients with pancreatic ductal adenocarcinoma (PDAC) underwent respiratory triggered DWI ss-EPI at a resolution of 2.5 × 2.5 × 3 mm3 with uniform undersampling in the phase encoding direction (AP axis) with an acceleration factor of 4. Data were reconstructed using the standard SENSE reconstruction routine of the vendor and an iterative SENSE reconstruction employing L1 regularization after a wavelet sparsifying transformation (L1-R SENSE). Retrospective reconstruction of the data with a lower number of averages was performed using both reconstruction methods. Two radiologists independently assessed noise artifacts, anatomical details and image quality (IQ) subjectively with a 4-point scale. Apparent diffusion coefficient (ADC) and covariance (CV) of ADC estimated from images reconstructed at a different number of averages for PDAC and the normal pancreas were assessed. RESULTS: L1-R SENSE resulted in higher IQ and less noise artifacts than SENSE. Anatomical details were significantly higher for SENSE in one reader. Mean ADC of PDAC and normal pancreas were significantly higher for L1-R SENSE than SENSE. L1-R SENSE revealed lower CV of ADC for normal pancreas compared to SENSE, whereas no difference was noted for PDAC. CONCLUSION: Compared with traditional SENSE reconstruction, L1-R SENSE effectively reduces band-like noise and improves the robustness of the ADC estimation from acquisitions using single-shot DW-EPI of the pancreas.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Imagen Eco-Planar , Artefactos , Imagen de Difusión por Resonancia Magnética/métodos , Imagen Eco-Planar/métodos , Humanos , Páncreas/diagnóstico por imagen , Páncreas/patología , Reproducibilidad de los Resultados , Estudios Retrospectivos
20.
Acad Radiol ; 28 Suppl 1: S234-S243, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-33390324

RESUMEN

RATIONALE AND OBJECTIVES: To investigate the effects of a reduced field-of-view (rFOV) acquisition in diffusion-weighted magnetic resonance imaging of the pancreas. MATERIALS AND METHODS: We enrolled 153 patients who underwent routine clinical MRI work-up including respiratory-triggered diffusion-weighted single-shot echo-planar imaging (DWI) with full field-of-view (fFOV, 3 × 3 × 4 mm3 voxel size) and reduced field-of-view (rFOV, 2.5 × 2.5 × 3 mm3 voxel size) for suspected pancreatic pathology. Two experienced radiologists were asked to subjectively rate (Likert Scale 1-4) image quality (overall image quality, lesion conspicuity, anatomical detail, artifacts). In addition, quantitative image parameters were assessed (apparent diffusion coefficient, apparent signal to noise ratio, apparent contrast to noise ratio [CNR]). RESULTS: All subjective metrics of image quality were rated in favor of rFOV DWI images compared to fFOV DWI images with substantial-to-high inter-rater reliability. Calculated ADC values of normal pancreas, pancreatic pathologies and reference tissues revealed no differences between both sequences. Whereas the apparent signal to noise ratio was higher in fFOV images, apparent CNR was higher in rFOV images. CONCLUSION: rFOV DWI provides higher image quality and apparent CNR values, favorable in the analysis of pancreatic pathologies.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Imagen Eco-Planar , Artefactos , Humanos , Páncreas/diagnóstico por imagen , Reproducibilidad de los Resultados