Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Sensors (Basel) ; 23(20)2023 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-37896470

RESUMEN

Facial expression recognition (FER) poses a complex challenge due to diverse factors such as facial morphology variations, lighting conditions, and cultural nuances in emotion representation. To address these hurdles, specific FER algorithms leverage advanced data analysis for inferring emotional states from facial expressions. In this study, we introduce a universal validation methodology assessing any FER algorithm's performance through a web application where subjects respond to emotive images. We present the labelled data database, FeelPix, generated from facial landmark coordinates during FER algorithm validation. FeelPix is available to train and test generic FER algorithms, accurately identifying users' facial expressions. A testing algorithm classifies emotions based on FeelPix data, ensuring its reliability. Designed as a computationally lightweight solution, it finds applications in online systems. Our contribution improves facial expression recognition, enabling the identification and interpretation of emotions associated with facial expressions, offering profound insights into individuals' emotional reactions. This contribution has implications for healthcare, security, human-computer interaction, and entertainment.


Asunto(s)
Reconocimiento Facial , Humanos , Reproducibilidad de los Resultados , Emociones , Cara , Expresión Facial
2.
Sensors (Basel) ; 21(13)2021 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-34209984

RESUMEN

Iodine is a trace chemical element fundamental for a healthy human organism. Iodine deficiency affects about 2 billion people worldwide causing from mild to severe neurological impairment, especially in children. Nevertheless, an adequate nutritional intake is considered the best approach to prevent such disorders. Iodine is present in seawater and seafood, and its common forms in the diet are iodide and iodate; most iodide in seawater is caused by the biological reduction of the thermodynamically stable iodate species. On this basis, a multisensor instrument which is able to perform a multidimensional assessment, evaluating iodide content in seawater and seafood (via an electrochemical sensor) and discriminating when the seafood is fresh or defrosted quality (via a Quartz Micro balance (QMB)-based volatile and gas sensor), is strategic for seafood quality assurance. Moreover, an electronic interface has been opportunely designed and simulated for a low-power portable release of the device, which should be able to identify seafood over or under an iodide threshold previously selected. The electrochemical sensor has been successfully calibrated in the range 10-640 µg/L, obtaining a root mean square error in cross validation (RMSECV) of only 1.6 µg/L. Fresh and defrosted samples of cod, sea bream and blue whiting fish have been correctly discriminated. This proof-of-concept work has demonstrated the feasibility of the proposed application which must be replicated in a real scenario.


Asunto(s)
Yoduros , Yodo , Animales , Niño , Humanos , Yodatos , Alimentos Marinos/análisis , Agua de Mar
3.
Sensors (Basel) ; 21(2)2021 Jan 12.
Artículo en Inglés | MEDLINE | ID: mdl-33445599

RESUMEN

In this study, a novel approach was developed to quantify endocannabinoids (eCBs), and was based on the liquid biosensor BIONOTE. This device is composed of a probe that can be immersed in a solution, and an electronic interface that can record a current related to the oxy-reductive reactions occurring in the sample. The two most representative members of eCBs have been analysed in vitro by BIONOTE: anandamide (N-arachidonoylethanolamine, AEA) and 2-arachidonoylglycerol (2-AG). Bovine serum albumin was used to functionalize the probe and improve the sensibility of the whole analytical system. We show that BIONOTE is able to detect both AEA and 2-AG at concentrations in the low nanomolar range, and to discriminate between these eCBs and their moieties arachidonic acid, ethanolamine and glycerol. Notably, BIONOTE distinguished these five different molecules, and it was also able to quantify AEA in human plasma. Although this is just a proof-of-concept study, we suggest BIONOTE as a cheap and user-friendly prototype sensor for high throughput quantitation of eCB content in biological matrices, with an apparent diagnostic potential for tomorrow's medicine.


Asunto(s)
Técnicas Biosensibles/métodos , Endocannabinoides/análisis , Ácidos Araquidónicos/análisis , Ácidos Araquidónicos/sangre , Técnicas Biosensibles/instrumentación , Endocannabinoides/sangre , Glicéridos/análisis , Glicéridos/sangre , Humanos , Alcamidas Poliinsaturadas/análisis , Alcamidas Poliinsaturadas/sangre
4.
Sensors (Basel) ; 21(11)2021 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-34071694

RESUMEN

Cerebrospinal fluid (CSF) analysis supports diagnosis of neurodegenerative diseases (NDs), however a number of issues limits its potentialities in clinical practice. Here, a newly developed technique for fluid voltammetry, relying on a simple sensor (BIOsensor-based multisensorial system for mimicking Nose, Tongue and Eyes, BIONOTE), was used to test the applicability for CSF analysis. BIONOTE was initially calibrated on an artificial CSF-like solution and then applied on human CSF, either immediately after collection or after refrigerated storage. Following optimization, it was used to evaluate 11 CSF samples correlating the electrochemical dataset with CSF routine parameters and biomarkers of neurodegeneration. Multivariate data analysis was performed for model elaboration and calibration using principal component analysis and partial least squares discriminant analysis. BIONOTE presented a high capacity to predict both physiological and pathological constituents of artificial CSF. It differentiated distinct fresh human CSF samples well but lost accuracy after refrigerated storage. The electrochemical analysis-derived data correlated with either CSF routine cytochemical indexes or a biomarker of neurodegeneration. BIONOTE resulted as being a reliable system for electrochemical analysis of CSF. The CSF fingerprint provided by the sensor has shown itself to be sensitive to CSF modification, thus it is potentially representative of CSF alteration. This result opens the way to its testing in further study addressed at assessing the clinical relevance of the methodology. Because of its advantages due to the ease and rapidity of the methodology, a validation study is now required to translate the technique into clinical practice and improve diagnostic workup of NDs.


Asunto(s)
Técnicas Biosensibles , Enfermedades Neurodegenerativas , Biomarcadores , Análisis Discriminante , Humanos
5.
Sensors (Basel) ; 21(8)2021 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-33920787

RESUMEN

The use of wearable sensors for health monitoring is rapidly growing. Over the past decade, wearable technology has gained much attention from the tech industry for commercial reasons and the interest of researchers and clinicians for reasons related to its potential benefit on patients' health. Wearable devices use advanced and specialized sensors able to monitor not only activity parameters, such as heart rate or step count, but also physiological parameters, such as heart electrical activity or blood pressure. Electrocardiogram (ECG) monitoring is becoming one of the most attractive health-related features of modern smartwatches, and, because cardiovascular disease (CVD) is one of the leading causes of death globally, the use of a smartwatch to monitor patients could greatly impact the disease outcomes on health care systems. Commercial wearable devices are able to record just single-lead ECG using a couple of metallic contact dry electrodes. This kind of measurement can be used only for arrhythmia diagnosis. For the diagnosis of other cardiac disorders, additional ECG leads are required. In this study, we characterized an electronic interface to be used with multiple contactless capacitive electrodes in order to develop a wearable ECG device able to perform several lead measurements. We verified the ability of the electronic interface to amplify differential biopotentials and to reject common-mode signals produced by electromagnetic interference (EMI). We developed a portable device based on the studied electronic interface that represents a prototype system for further developments. We evaluated the performances of the developed device. The signal-to-noise ratio of the output signal is favorable, and all the features needed for a clinical evaluation (P waves, QRS complexes and T waves) are clearly readable.


Asunto(s)
Pierna , Dispositivos Electrónicos Vestibles , Arritmias Cardíacas , Electrocardiografía , Electrodos , Humanos
6.
Sensors (Basel) ; 20(3)2020 Jan 25.
Artículo en Inglés | MEDLINE | ID: mdl-31991728

RESUMEN

In this work an array of chemical sensors for gas detection has been developed, starting with a commercial sensor platform developed by Microchip (GestIC), which is normally used to detect, trace, and classify hand movements in space. The system is based on electric field changes, and in this work, it has been used as mechanism revealing the adsorption of chemical species CO2 and O2. The system is composed of five electrodes, and their responses were obtained by interfacing the sensors with an acquisition board based on an ATMEGA 328 microprocessor (Atmel MEGA AVR microcontroller). A dedicated measurement chamber was designed and prototyped in acrylonitrile butadiene styrene (ABS) using an Ultimaker3 3D printer. The measurement cell size is 120 × 85 mm. Anthocyanins (red rose) were used as a sensing material in order to functionalize the sensor surface. The sensor was calibrated using different concentrations of oxygen and carbon dioxide, ranging from 5% to 25%, mixed with water vapor in the range from 50% to 90%. The sensor exhibits good repeatability for CO2 concentrations. To better understand the sensor response characteristics, sensitivity and resolution were calculated from the response curves at different working points. The sensitivity is in the order of magnitude of tens to hundreds of µV/% for CO2, and of µV/% in the case of O2. The resolution is in the range of 10-1%-10-3% for CO2, and it is around 10-1% for O2. The system could be specialized for different fields, for environmental, medical, and food applications.

7.
J Allergy Clin Immunol ; 143(5): 1811-1820.e7, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30529449

RESUMEN

BACKGROUND: Severe asthma is a heterogeneous condition, as shown by independent cluster analyses based on demographic, clinical, and inflammatory characteristics. A next step is to identify molecularly driven phenotypes using "omics" technologies. Molecular fingerprints of exhaled breath are associated with inflammation and can qualify as noninvasive assessment of severe asthma phenotypes. OBJECTIVES: We aimed (1) to identify severe asthma phenotypes using exhaled metabolomic fingerprints obtained from a composite of electronic noses (eNoses) and (2) to assess the stability of eNose-derived phenotypes in relation to within-patient clinical and inflammatory changes. METHODS: In this longitudinal multicenter study exhaled breath samples were taken from an unselected subset of adults with severe asthma from the U-BIOPRED cohort. Exhaled metabolites were analyzed centrally by using an assembly of eNoses. Unsupervised Ward clustering enhanced by similarity profile analysis together with K-means clustering was performed. For internal validation, partitioning around medoids and topological data analysis were applied. Samples at 12 to 18 months of prospective follow-up were used to assess longitudinal within-patient stability. RESULTS: Data were available for 78 subjects (age, 55 years [interquartile range, 45-64 years]; 41% male). Three eNose-driven clusters (n = 26/33/19) were revealed, showing differences in circulating eosinophil (P = .045) and neutrophil (P = .017) percentages and ratios of patients using oral corticosteroids (P = .035). Longitudinal within-patient cluster stability was associated with changes in sputum eosinophil percentages (P = .045). CONCLUSIONS: We have identified and followed up exhaled molecular phenotypes of severe asthma, which were associated with changing inflammatory profile and oral steroid use. This suggests that breath analysis can contribute to the management of severe asthma.


Asunto(s)
Asma/diagnóstico , Nariz Electrónica , Eosinófilos/patología , Inflamación/diagnóstico , Neutrófilos/patología , Adulto , Pruebas Respiratorias , Análisis por Conglomerados , Estudios de Cohortes , Progresión de la Enfermedad , Espiración , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Fenotipo , Índice de Severidad de la Enfermedad
8.
Wound Repair Regen ; 27(3): 288-291, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30663822

RESUMEN

The timely recognition of leg ulcers (LU) etiology and infection is pivotal to optimize management and accelerate healing. The objective of this proof-of-concept study was to test the diagnostic performance of voltammetric analysis (VA) on ulcer exudate to identify LU etiology, infection, and predict clinical course. We enrolled 25 patients aged ≥60 years, affected by 42 venous/arterial LU. Clinical examination (Leg Ulcer Measurement Tool score, LUMT), swab culture, and VA were performed at baseline and 30 days. The ability of VA to predict outcomes was tested using partial least square-discrimination analysis. Mean age was 75 years (SD 11.1), 9/25 were male. The accuracy, sensitivity, and specificity vs. etiology were 97.4, 100%, and 94.1%, respectively; the corresponding figures were 95.2%, 100%, 88.9%, for infection and 94%, 84.6%, 100% for predicted objective LUMT worsening. VA is a promising diagnostic/prognostic tool for management of LU that may allow a more timely targeted therapy.


Asunto(s)
Técnicas Electroquímicas , Úlcera de la Pierna/diagnóstico , Úlcera de la Pierna/microbiología , Anciano , Diagnóstico Precoz , Femenino , Humanos , Úlcera de la Pierna/fisiopatología , Masculino , Examen Físico , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Úlcera Varicosa/diagnóstico , Úlcera Varicosa/fisiopatología , Cicatrización de Heridas
9.
Sensors (Basel) ; 19(18)2019 Sep 12.
Artículo en Inglés | MEDLINE | ID: mdl-31547403

RESUMEN

One of the basic needs of professional athletes is the real-time and non-invasive monitoring of their activities. The use of these kind of data is necessary to develop strategies for specific tailored training in order to improve performances. The sensor system presented in this work has the aim to adopt a novel approach for the monitoring of physiological parameters, and athletes' performances, during their training. The anaerobic threshold is herein identified with the monitoring of the lactate concentration and the respiratory parameters. The data collected by the sensor are used to build a model using a supervised method (based on the partial least squares method, PLS) to predict the values of the parameters of interest. The sensor is able to measure the lactate concentration from a sample of saliva and it can estimate a respiratory parameter, such as maximal oxygen consumption, maximal carbon dioxide production and respiratory rate from a sample of exhaled breath. The main advantages of the device are the low power; the wireless communication; and the non-invasive sampling method, which allow its use in a real context of sport practice.


Asunto(s)
Atletas , Ejercicio Físico , Ácido Láctico/análisis , Monitoreo Fisiológico/métodos , Pruebas Respiratorias , Ejercicio Físico/fisiología , Humanos , Análisis de los Mínimos Cuadrados , Monitoreo Fisiológico/estadística & datos numéricos , Consumo de Oxígeno/fisiología , Prueba de Estudio Conceptual , Saliva
10.
J Transl Med ; 16(1): 17, 2018 01 25.
Artículo en Inglés | MEDLINE | ID: mdl-29370807

RESUMEN

BACKGROUND: Dipstick test is widely used to support the diagnosis of urinary tract infections (UTI). It is effective in ruling out UTI, but urine culture is needed for diagnosis confirmation. In this study we compared the accuracy of voltammetric analysis (VA) with that of DT to detect UTI (diagnosed using urine culture), and its usefulness as a second-stage test in people with positive DT. METHODS: 142 patients were enrolled with no exclusion criteria. VA was performed using the BIONOTE device. Partial Least Square Discrimination Analysis was used to predict UTI based on VA data; diagnostic performance was evaluated using sensitivity, specificity, positive and negative predictive values (PPV and NPV, respectively), positive and negative likelihood ratios (LR), accuracy, diagnostic odds ratio (DOR). RESULTS: Mean age was 76.6 years (SD 12.6), 57% were male. VA had a better overall performance respect to DT in detecting UTI with accuracy 81.7% vs 75.9%, specificity 90.8% vs 82.5%, PPV 75% vs 61.4%, positive LR 6.68 vs 3.5, DOR 17.7 vs 7.47; sensibility, NPV and negative LR of the two tests were similar. VA had an accuracy of 82.4% in discriminating bacterial from fungal infections. When added as a second-stage test, VA identified 9 of the 17 false positive patients, with a net specificity of 91.7%, sensitivity 54%, PPV 75% and NPV 81%. CONCLUSIONS: VA is a quick and easy method that may be used as a second stage after DT to reduce the number of urine culture and of inappropriate antibiotic prescriptions.


Asunto(s)
Técnicas Electroquímicas/métodos , Infecciones Urinarias/diagnóstico , Anciano , Femenino , Humanos , Masculino , Infecciones Urinarias/microbiología , Infecciones Urinarias/orina
11.
Eur Respir J ; 49(4)2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-28446552

RESUMEN

Breath tests cover the fraction of nitric oxide in expired gas (FeNO), volatile organic compounds (VOCs), variables in exhaled breath condensate (EBC) and other measurements. For EBC and for FeNO, official recommendations for standardised procedures are more than 10 years old and there is none for exhaled VOCs and particles. The aim of this document is to provide technical standards and recommendations for sample collection and analytic approaches and to highlight future research priorities in the field. For EBC and FeNO, new developments and advances in technology have been evaluated in the current document. This report is not intended to provide clinical guidance on disease diagnosis and management.Clinicians and researchers with expertise in exhaled biomarkers were invited to participate. Published studies regarding methodology of breath tests were selected, discussed and evaluated in a consensus-based manner by the Task Force members.Recommendations for standardisation of sampling, analysing and reporting of data and suggestions for research to cover gaps in the evidence have been created and summarised.Application of breath biomarker measurement in a standardised manner will provide comparable results, thereby facilitating the potential use of these biomarkers in clinical practice.


Asunto(s)
Pruebas Respiratorias/métodos , Enfermedades Pulmonares/diagnóstico , Óxido Nítrico/análisis , Compuestos Orgánicos Volátiles/análisis , Biomarcadores/análisis , Europa (Continente) , Espiración , Humanos , Enfermedades Pulmonares/terapia , Sociedades Médicas
12.
Liver Int ; 37(2): 242-250, 2017 02.
Artículo en Inglés | MEDLINE | ID: mdl-27496750

RESUMEN

BACKGROUND & AIMS: The spectrum of volatile organic compounds in the exhaled breath (breath-print, BP) has been shown to characterize patients with cirrhosis and with worse hepatic function. However, the association of different BPs with clinically relevant outcomes has not been described yet. Hence, we aimed to evaluate the association between BPs, mortality and hospitalization in cirrhotic patients and to compare it with that of the "classical" prognostic indices (Child-Pugh Classification [CPC] and MELD). METHODS: Eighty-nine cirrhotic patients (M/F 59/30, mean age 64.8 ± 11.3, CPC A/B/C 37/33/19) were recruited and followed up for a median time of 23 months. Clinical and biochemical data were collected. Breath collection and analysis were obtained through Pneumopipe® and BIONOTE e-nose respectively. RESULTS: Four different BP clusters (A, B, C, D) were identified. BP clusters A and D were associated with a significantly increased risk of mortality (HR 2.9, 95% confidence intervals [CI] 1.5-5.6) and hospitalization (HR 2.6, 95% CI 1.4-4.6), even in multiple adjusted models including CPC and MELD score (adjusted [a]HR 2.8, 95% CI 1.1-7.0 for mortality and aHR 2.2, 95% CI 1.1-4.2 for hospitalization). CPC C maintained the strongest association with both mortality (aHR 17.6, 95% CI 1.8-174.0) and hospitalization (aHR 12.4, 95% CI 2.0-75.8). CONCLUSIONS: This pilot study demonstrates that BP clusters are associated with significant clinical endpoints (mortality and hospitalization) even independently from "classical" prognostic indices. Even though further studies are warranted on this topic, our findings suggest that the e-nose may become an adjunctive aid to stratify the risk of adverse outcomes in cirrhotic patients.


Asunto(s)
Pruebas Respiratorias/instrumentación , Nariz Electrónica , Cirrosis Hepática/diagnóstico , Pruebas de Función Hepática/instrumentación , Anciano , Femenino , Hospitalización , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Medición de Riesgo , Índice de Severidad de la Enfermedad , Análisis de Supervivencia , Factores de Tiempo , Compuestos Orgánicos Volátiles/análisis
13.
Lung ; 195(2): 157-165, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-28238110

RESUMEN

Electronic noses (e-noses) are based on arrays of different sensor types that respond to specific features of an odorant molecule, mostly volatile organic compounds (VOCs). Differently from gas chromatography and mass spectrometry, e-noses can distinguish VOCs spectrum by pattern recognition. E-nose technology has successfully been used in commercial applications, including military, environmental, and food industry. Human-exhaled breath contains a mixture of over 3000 VOCs, which offers the postulate that e-nose technology can have medical applications. Based on the above hypothesis, an increasing number of studies have shown that breath profiling by e-nose could play a role in the diagnosis and/or screening of various respiratory and systemic diseases. The aim of the present study was to review the principal literature on the application of e-nose technology in respiratory diseases.


Asunto(s)
Asma/diagnóstico , Nariz Electrónica , Neoplasias Pulmonares/diagnóstico , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico , Infecciones del Sistema Respiratorio/diagnóstico , Compuestos Orgánicos Volátiles/análisis , Pruebas Respiratorias , Humanos , Mesotelioma/diagnóstico , Neoplasias Pleurales/diagnóstico , Apnea Obstructiva del Sueño/diagnóstico
14.
Sensors (Basel) ; 17(11)2017 Oct 28.
Artículo en Inglés | MEDLINE | ID: mdl-29143768

RESUMEN

The aim of this work is the development of a contactless capacitive sensory system for the detection of (Electrocardiographic) ECG-like signals. The acquisition approach is based on a capacitive coupling with the patient body performed by electrodes integrated in a front-end circuit. The proposed system is able to detect changes in the electric charge related to the heart activity. Due to the target signal weakness and to the presence of other undesired signals, suitable amplification stages and analogue filters are required. Simulated results allowed us to evaluate the effectiveness of the approach, whereas experimental measurements, recorded without contact to the skin, have validated the practical effectiveness of the proposed architecture. The system operates with a supply voltage of ±9 V with an overall power consumption of about 10 mW. The analogue output of the electronic interface is connected to an ATmega328 microcontroller implementing the A/D conversion and the data acquisition. The collected data can be displayed on any multimedia support for real-time tracking applications.


Asunto(s)
Electrocardiografía , Electrodos , Diseño de Equipo , Humanos , Procesamiento de Señales Asistido por Computador
15.
Sleep Breath ; 19(2): 623-30, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25323296

RESUMEN

INTRODUCTION: In obstructive sleep apnea syndrome (OSAS), exhaled volatile organic compounds (VOCs) change after long-term continuous positive airway pressure (CPAP). The objective of the study was to verify whether changes in VOCs pattern are detectable after the first night of CPAP and to identify correlates, if any, of these changes. METHODS: Fifty OSAS patients underwent a multidimensional assessment and breath print (BP) analysis through 28 sensors e-nose at baseline and after the first night of CPAP. Boxplots of individual BP evolution after CPAP and groups were compared by ANOVA and Fisher's exact t. Partial least square discriminant analysis (PLS-DA), with leave-one-out as cross-validation was used to calculate to which extent basal BP could predicts changes in apnea-hypopnea index (AHI). RESULTS: CPAP was effective in all the patients (delta AHI 35.8 events/h; residual AHI 6.0 events/h). BP dramatically changed after a single-night CPAP and changes conformed to two well-distinguished patterns: pattern C (n = 29), characterized by consonant boxplots, and pattern D (n = 21), with variably discordant boxplots. The average number of comorbid diseases (1.55 [standard deviation, SD 1.0] in group C, 3.14 [SD 1.8] in group D, p < 0.001) and the prevalence of selected comorbidity (diabetes mellitus, metabolic syndrome, and chronic heart failure), were the only features distinguishing groups. CONCLUSION: We found that BP change after a single night of CPAP largely depends upon comorbidity. Comorbidity likely contributes to phenotypic variability in OSAS population. BP might qualify as a surrogate index of the response to and, later, compliance with CPAP.


Asunto(s)
Presión de las Vías Aéreas Positiva Contínua , Polisomnografía , Apnea Obstructiva del Sueño/diagnóstico , Apnea Obstructiva del Sueño/terapia , Compuestos Orgánicos Volátiles/análisis , Anciano , Biomarcadores , Comorbilidad , Complicaciones de la Diabetes/diagnóstico , Complicaciones de la Diabetes/epidemiología , Complicaciones de la Diabetes/terapia , Nariz Electrónica , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Síndrome Metabólico/diagnóstico , Síndrome Metabólico/epidemiología , Síndrome Metabólico/terapia , Persona de Mediana Edad , Cooperación del Paciente , Apnea Obstructiva del Sueño/epidemiología , Estadística como Asunto , Resultado del Tratamiento
16.
Sensors (Basel) ; 15(9): 21660-72, 2015 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-26404285

RESUMEN

Methods for the chemical and sensorial evaluation of olive oil are frequently changed and tuned to oppose the increasingly sophisticated frauds. Although a plethora of promising alternatives has been developed, chromatographic techniques remain the more reliable yet, even at the expense of their related execution time and costs. In perspective of a continuous increment in the number of the analyses as a result of the global market, more rapid and effective methods to guarantee the safety of the olive oil trade are required. In this study, a novel artificial sensorial system, based on gas and liquid analysis, has been employed to deal with olive oil genuineness and authenticity issues. Despite these sensors having been widely used in the field of food science, the innovative electronic interface of the device is able to provide a higher reproducibility and sensitivity of the analysis. The multi-parametric platform demonstrated the capability to evaluate the organoleptic properties of extra-virgin olive oils as well as to highlight the presence of adulterants at blending concentrations usually not detectable through other methods.


Asunto(s)
Técnicas Biosensibles/instrumentación , Contaminación de Alimentos/análisis , Aceite de Oliva/química , Análisis Discriminante , Análisis de los Mínimos Cuadrados
17.
Sensors (Basel) ; 15(8): 19583-96, 2015 Aug 10.
Artículo en Inglés | MEDLINE | ID: mdl-26266414

RESUMEN

The aim of this randomized clinical trial was to evaluate whether a recently described multi-sensor approach called BIONOTE(®) is accurate enough to verify the efficacy of treatment of patients with halitosis. A treatment with Lactobacillus brevis (CD2)-containing lozenges, compared with placebo was tested. The BIONOTE(®) was compared with traditional techniques used to detect halitosis: OralChroma™ and two calibrated odor judges enrolled for the organoleptic assessments. Twenty patients (10 treated and 10 placebo), suffering from active phase halitosis were included in the study. Treatment consisted of Lactobacillus brevis (CD2)-containing lozenges or placebo, 4 tablets/day for 14 days. t0 was before the beginning of the study; t1 was day 7 and t2 was day 14. The effectiveness of treatment was assessed through: (1) Rosenberg score; (2) Winkel tongue coating index (WTCI) anterior and posterior; (2) OralChroma™; (3) the new developed multi-sensor approach, called BIONOTE(®) (test technique). Only the WTCI anterior revealed statistically significant changes between t0 and t2 data (p = 0.014) in the treated group. Except for the WTCI anterior, all diagnostic methods revealed the lack of effectiveness for halitosis of a 14-days treatment with Lactobacillus brevis (CD2)-containing lozenges. The BIONOTE(®) multisensor system seems accurate in addition to OralChroma™ to assess the initial condition of halitosis and its mitigation during treatment.


Asunto(s)
Técnicas Biosensibles/instrumentación , Halitosis/diagnóstico , Halitosis/terapia , Levilactobacillus brevis/metabolismo , Adulto , Demografía , Método Doble Ciego , Halitosis/microbiología , Humanos , Masculino , Placebos , Comprimidos , Resultado del Tratamiento
18.
Diagnostics (Basel) ; 14(5)2024 Mar 06.
Artículo en Inglés | MEDLINE | ID: mdl-38473033

RESUMEN

Ovarian cancer (OC) is the eighth most common cancer in women. Since screening programs do not exist, it is often diagnosed in advanced stages. Today, the detection of OC is based on clinical examination, transvaginal ultrasound (US), and serum biomarker (Carbohydrate Antigen 125 (CA 125) and Human Epididymis Protein 4 (HE4)) dosage, with a sensitivity of 88% and 95%, respectively, and a specificity of 84% for US and 76% for biomarkers. These methods are clearly not enough, and OC in its early stages is often missed. Many scientists have recently focused their attention on volatile organic compounds (VOCs). These are gaseous molecules, found in the breath, that could provide interesting information on several diseases, including solid tumors. To detect VOCs, an electronic nose was invented by a group of researchers. A similar device, the e-tongue, was later created to detect specific molecules in liquids. For the first time in the literature, we investigated the potential use of the electronic nose and the electronic tongue to detect ovarian cancer not just from breath but also from urine, blood, and plasma samples.

19.
J Thorac Oncol ; 2024 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-38762120

RESUMEN

INTRODUCTION: Electronic nose (E-nose) technology has reported excellent sensitivity and specificity in the setting of lung cancer screening. However, the performance of E-nose specifically for early-stage tumors remains unclear. Therefore, the aim of our study was to assess the diagnostic performance of E-nose technology in clinical stage I lung cancer. METHODS: This phase IIc trial (NCT04734145) included patients diagnosed with a single greater than or equal to 50% solid stage I nodule. Exhalates were prospectively collected from January 2020 to August 2023. Blinded bioengineers analyzed the exhalates, using E-nose technology to determine the probability of malignancy. Patients were stratified into three risk groups (low-risk, [<0.2]; moderate-risk, [≥0.2-0.7]; high-risk, [≥0.7]). The primary outcome was the diagnostic performance of E-nose versus histopathology (accuracy and F1 score). The secondary outcome was the clinical performance of the E-nose versus clinicoradiological prediction models. RESULTS: Based on the predefined cutoff (<0.20), E-nose agreed with histopathologic results in 86% of cases, achieving an F1 score of 92.5%, based on 86 true positives, two false negatives, and 12 false positives (n = 100). E-nose would refer fewer patients with malignant nodules to observation (low-risk: 2 versus 9 and 11, respectively; p = 0.028 and p = 0.011) than would the Swensen and Brock models and more patients with malignant nodules to treatment without biopsy (high-risk: 27 versus 19 and 6, respectively; p = 0.057 and p < 0.001). CONCLUSIONS: In the setting of clinical stage I lung cancer, E-nose agrees well with histopathology. Accordingly, E-nose technology can be used in addition to imaging or as part of a "multiomics" platform.

20.
Sensors (Basel) ; 13(12): 16625-40, 2013 Dec 04.
Artículo en Inglés | MEDLINE | ID: mdl-24304640

RESUMEN

Sensors are often organized in multidimensional systems or networks for particular applications. This is facilitated by the large improvements in the miniaturization process, power consumption reduction and data analysis techniques nowadays possible. Such sensors are frequently organized in multidimensional arrays oriented to the realization of artificial sensorial systems mimicking the mechanisms of human senses. Instruments that make use of these sensors are frequently employed in the fields of medicine and food science. Among them, the so-called electronic nose and tongue are becoming more and more popular. In this paper an innovative multisensorial system based on sensing materials of biological origin is illustrated. Anthocyanins are exploited here as chemical interactive materials for both quartz microbalance (QMB) transducers used as gas sensors and for electrodes used as liquid electrochemical sensors. The optical properties of anthocyanins are well established and widely used, but they have never been exploited as sensing materials for both gas and liquid sensors in non-optical applications. By using the same set of selected anthocyanins an integrated system has been realized, which includes a gas sensor array based on QMB and a sensor array for liquids made up of suitable Ion Sensitive Electrodes (ISEs). The arrays are also monitored from an optical point of view. This embedded system, is intended to mimic the working principles of the nose, tongue and eyes. We call this setup BIONOTE (for BIOsensor-based multisensorial system for mimicking NOse, Tongue and Eyes). The complete design, fabrication and calibration processes of the BIONOTE system are described herein, and a number of preliminary results are discussed. These results are relative to: (a) the characterization of the optical properties of the tested materials; (b) the performance of the whole system as gas sensor array with respect to ethanol, hexane and isopropyl alcohol detection (concentration range 0.1-7 ppm) and as a liquid sensor array (concentration range 73-98 µM).


Asunto(s)
Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Diseño de Equipo/instrumentación , Ensayo de Materiales/instrumentación , Electrodos , Nariz Electrónica , Humanos , Miniaturización/métodos , Transductores
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA